HomeMy WebLinkAboutFile Documents.555 E Durant Ave.0109.2018.ACBK IrriA COMcheck Software Version 4.0.7.1
Exterior Lighting Compliance Certificate
Project Information
Energy Code: 2015 IECC
Project Title:
Project Type: Alteration
Exterior Lighting Zone 4 (High activity metropolitan commercial district)
Construction Site: Owner/Agent: Designer/Contractor:
555 E Durant Joe Raczak John Patrick
Aspen, CO 81611 North of Nell HOA Osage Inc
555 E Durant 103 Ranch Lane
Asepn, CO 81611 Glenwood Springs, CO 81601
970.925.1511 970.309.3239
jraczak@sopris.net osage.ex@gmail.com
Allowed Exterior Lighting Power
A B C D E
Area/Surface Category Quantity Allowed Tradable Allowed Watts
Watts/Unit Wattage (B X C)
Walkway>=10 feet wide 1249 ft2 0.2 Yes 250
Total Tradable Watts(a)= 250
Total Allowed Watts= 250
Total Allowed Supplemental Watts(b)= 1300
(a)Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b)A supplemental allowance equal to 1300 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces.
Proposed Exterior Lighting Power
A B C D E
Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
Walkway>= 10 feet wide(1249 ft2):Tradable Wattage
LED 1:Other: 1 24 15 360
Total Tradable Proposed Watts= 360
Exterior Lighting PASSES: Design 77% better than code
Exterior Lighting Compliance Statement
Compliance Statement: The proposed exterior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application.The proposed exterior lighting
systems have been designed to meet the 2015 IECC re.uire ents in COMcheck Version 4.0.7.1 and to comply with any
applicable mandatory requirements listed in the Inspec .• f hecklist.
John Patrick - Contractor .1 111218
Name-Title .74:tu pate
Rai
r„)
11/12/2018
RCUMPLIANCE
justinh
Project Title: Report date: 11/12/18
Data filename: C:\Users\justinh\Desktop\QUICK SAVES FOR BLUEBEAM UPLOADS\555 E Durant.cck Page 1 of 5
COMcheck Software Version 4.0.7.1
Inspection Checklist
Energy Code: 2015 IECC
rA
Requirements: 0.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# Plan Review Complies? Comments/Assumptions
& Req.ID
C103.2 Plans, specifications, and/or EComplies
[PR8]1 calculations provide all information Does Not
with which compliance can be
determined for the exterior lighting ❑Not Observable
and electrical systems and equipment ❑Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include exterior
lighting power calculations, wattage of
bulbs and ballasts,transformers and
control devices.
Additional Comments/Assumptions:
DAVr
r-.)
11/12/2018
RCAMPLIANCE
Tirrjvstinh
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impa er k
Project Title: Report date: 11/12/18
Data filename: C:\Users\justinh\Desktop\QUICK SAVES FOR BLUEBEAM UPLOADS\555 E Durant.cck Page 2 of 5
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
& Req.ID
C405.2.5 ;Automatic lighting controls for exterior ❑Complies
[EL25]nu° lighting installed. Controls will be ❑Does Not
daylight controlled, set based on
business operation time-of-day, or [Not Observable
reduce connected lighting > 30%. ❑Not Applicable
Additional Comments/Assumptions:
Rare
r„)
11/12/2018
RCAMPLIANCE
ust. nh
'High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Imps
Project Title: Report date: 11/12/18
Data filename: C:\Users\justinh\Desktop\QUICK SAVES FOR BLUEBEAM UPLOADS\555 E Durant.cck Page 3 of 5
Section
# Final Inspection Complies? Comments/Assumptions
& Req.ID
C405.5.1 ;Exterior lighting power is consistent ❑Complies See the Exterior Lighting fixture schedule for values.
[F119]1 with what is shown on the approved ❑Does Not
lighting plans, demonstrating
proposed watts are less than or equal ❑Not Observable
Ito allowed watts. ❑Not Applicable
Additional Comments/Assumptions:
Rare
r„)
11/12/2018
RCAMPLIANCE
ust�nh
'High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Imps
Project Title: Report date: 11/12/18
Data filename: C:\Users\justinh\Desktop\QUICK SAVES FOR BLUEBEAM UPLOADS\555 E Durant.cck Page 4 of 5
reyllima r")
/12/2018 j
RACOOtaiiii.IANCE
justinh
Project Title: Report date: 11/12/18