HomeMy WebLinkAboutFile Documents.101 E Bleeker St.0110-2020-BRES (3) Submittal 09 29 00
A
AM GYPSUM AN FireBloc pT e C
�
American Gypsum
3811 Turtle Creek Blvd.,#1200
klE Dallas,TX75
all 219 Gypsum Wallboard
1 214-530-5500
www.americangypsum.com
Technical Information
y. 1-800-545-6302 ext.5607
DESCRIPTION FireBloc®Type C gypsum wallboard is the preferred product in the industry due to its consistently high quality standards. •
Additional properties enhance the core ofthis type Xwallboard to achieve superior performance when used in specific fire rated
assemblies.The fire-resistant gypsum core is encased in 100%recycled natural-finish paper on the face side and sturdy liner paper on the backside.The face paper
is folded around the long edges to reinforce and protect the core,with the ends being square-cut and finished smooth.Long edges ofthe panels are tapered,allowing
joints to be reinforced and concealed with a joint compound system.
FireBloc Type C wallboard is available in 1/2"and 5/8"thicknesses and in a variety of lengths for standard construction uses.
American Gypsum products contain no asbestos and no detectable levels of formaldehyde.
EGREENGUARD CE:R 111 11•D FireBloc Type C gypsum wallboard has achieved UL Environment's GREENGUARD GOLD Certification.GREENGUARD
m FROMUf.FNVU ON J Nr Certified products are scientifically proven to meet some of the world's most rigorous,third-party chemical emissions standards,
helping reduce indoor air pollution and the risk of chemical exposure while aiding in the creation of healthier indoor environments.
3 Z For more information,visit www.ulcom/gg
BASIC USES FireBloc Type C wallboard is used as a covering material for interior walls and ceilings in residential and couuorcial applications
Qthat often require specific fire rated assemblies.It is designed for direct attachment by screws,nails or adhesive to wood or metal framing.
fA With joints covered,FireBloc Type C gypsum wallboard will resist the passage of smoke.For additional information on smoke bathers,refir to Gypsum Association
publication,`Building and Inspecting Smoke Bathers"(GA-618),which can be found at www.americangypsum.com under`Technical Data"-click on Gypsum
Association literature.
1:1)
LI N, I'AI'IONS FireBloc Type C gypsum wallboard is intended for interior applications only.
Avoid exposure to temperatures exceeding 125°F (52°C), e.g., located adjacent to wood burning stoves and or heating
appliances.
Avoid exposure to excessive or continuous moisture before,during and after installation,e.g.,swimming pools,saunas or steam moms.Eliminate any sources of
moisture immediately.
CD FireBloc Type C gypsum wallboard is a nonstructural product and should not be used as a nailing base.
Spacing ofwall or ceiling framing should not exceed the recommendations below.
MAX1tvUMSPACING OF FRAMING(WOOD OR NETAL)
Single Ply Maximum ximum Framing
Thickness 0/C Spacing
etCeilings 1/2"or 5/8" Parallel to Framing 16'b/c
C.) 1/2"or 5/8" Perpendicular to Framing 24'b/c
Parallel or Pe ndicular
Walls 1/2"or 5/8" Framing 24'b/c
004. Tor Ceiling Applications-When using a hand or water-based texture for decoration,1/2"FireBloc C
wallboard is to be installed perpendicular to framing spaced no more then 16'b/c.
To prevent noticeable sag in ceilings,the weight of overlaid unsupported insulation should not exceed the following reconnoendations:
FRAMNG PRODUCT PSF(LBS.PER S/F)OF INSULATION
24'b/c 1/2"FireBloc Type C 1.3(6.3 kg/M)
161)/c 1/2"FireBloc Type C 2.2(10.7 kg/Ivg)
a.
V 24'b/c 5/8"FireBloc Type C 2.2(10.7 kg/M)
0
-413
a
Insulation blankets or batts should be recessed,with flanges attached or friction fitted to the sides of the studs or joists.
a
STORAGE AND HANDLIN Gypsum board does not generate or support the growth ofmokl when it is properly transported,stored,handled,installed,and
maintained.However,mold spores are present everywhere and when conditions are favorable;mold can growon practically any
surface.GYPSUMBOARD MUST BE KEPT DRYto prevent the growth of mold.
Gypsum board must be stored in an area that protects it from adverse weather conditions,condensation,and other forms of moisture.Job site conditions that can
expose gypsum board to water or moisture must be avoided.
STORAGE&HANDLING Gypsum board must be protected during transit with a weather-tight cover in good condition.Plastic shipping bags are intended
to provide protection during transit only and must be promptly removed upon anival of the load.Failure to remove the shipping
bag can increase the likelihood of developing conditions favorable to the growth of mold.
Gypsum board that has visible mold growth must not be used.For additional information,refer to Gypsum Association publication,'Guidelines for the Prevention
of Nbld Growth on Gypsum Wallboard"(GA238),which can be found at www.americangypsum.com under`Technical Data"-click on Gypsum Association
Literature.
Gypsum board must be stored off the ground and under protective cover.Sufficient risers must be used to assure support for the entire length of the wallboard to
prevent sagging.
Gypsum board must be delivered to the job site as near to the time it will be used as possible.Individuals delivering gypsum board to jobsites should ensure that it
is carved,not dragged,to place of storage/installation to prevent damage to finished edges.
Gypsum board shall always be stacked flat-NEVER on edge or end.Gypsum board stacked on edge or end is unstable and presents a serious hazard should it
accidentally topple.Gypsum board should be placed so weight is evenly distributed and the floor is not overloaded.
GOOD BUILDING PRACTICES Installation-The building temperature shall be maintained at not less than 50°F(10°C)for adhesive application of gypsum
board,during joint treatment,texturing,and decoration.When a temporary heat source is used the temperature shall not be
more than 95°F(35°C)in any given room or area.Adequate and continuous ventilation shall be provided in the warring area during the installation and the drying
or curing period.
The design professional has the ultimate responsibility for location of control joints.
Decoration-The design professional,contractor and or owner shall review Gypsum Association's bulletin GA214,'Recommended Levels of Gypsum Board
Finish':in order to specify the proper level of drywall finishing needed to assure the desired results.(GA214 can be found at www.americangypsum.com under
a n `Technical Data"-click on Gypsum Association literature)
For best paintingresults,all surfaces,includingjoint compound,should be clean,dust-free and not glossy.To equalize the porosities between the face paper and
� Sb Y q p P P
joint compound and improve fastener and joint concealment,the surface shall be primed and sealed with a full-bodied drywall primer before texturing or final
Qdecoration.The selection of the proper paint to give the specified or desired finished characteristics is the responsibility ofthe design professional,contractor and
f A or owner.
Gypsum board that is to have a wall covering applied to it should be prepared and primed as described for painting.
a) APPLICABLE STANDARDS Manufacturing ASTMC 1396 s ction 5(C 36)
cation SS-L-30D Type IIL Grade X
Installation ASTMC 840
Gypsum Association GA216
Gypsum Association GA214
Surface Burning ASTME 84
CD Characteristics me Spread 0
Smoke Developed 0
PRODUCT DATA SIZES
Thickness Widths Lengths Edge Type ULType
Z 1/2"(12.7mm) 4'(1219mm) 8'-12'(2438u,ui—3658mm) Tapered AG-C
✓2 5/8"(15.9mm) 4'(1219mm) 8'-12'(2438mm—3658mm) Tapered AG-C
W Special lengths or edges maybe available on special order.Consult your American Gypsum sales representative for details.
Q° Thermal Resistance"R"Value 1/2"=0.50
5/8"=0.61
704
FIRE RESISTANCE RATINGS Fire rated assemblies are specified from tests perfonned by independent laboratories.These designs are made up of specific
materials in a precise configuration.When choosing construction details to meet certain fire resistance requirements,care must
be taken to insure that each component of the selected assembly is the one specified in the test and are assembled in accordance with the requirements of the
design.
N
Y
v
SUBMITTAL APPROVALS Job Name: