File Documents.101 E Bleeker St.0110-2020-BRES (5)
USG Interior Panel& SUBMITTAL SHEET Finishing Solutions USG SHEETROCKR BRAND FIRECODE® C PANELS ;'R ... 1/2 in.(12.7 mm)and 5/8 in.(15.9 mm)enhanced proprietary Type X panels for interior wall and ceiling applications a' • , • • Comply with ASTM C1396,Standard Specification for Gypsum Board,for 1/2 in.(12.7 mm), • Underwriters Laboratorieswallboard Inc.In.(UL)Classification ation as to fire resistance,surface-burning characteristics and noncombustibility 4 • Achieved GREENGUARD Gold Certification and qualifies as a low VOC emitting material (meets CA 01350) DESCRIPTION Available in 1/2 in.(12.7 mm)and 5/8 in.(15.9 mm)thicknesses,USG Sheetrock®Brand Firecode®C Panels(UL Type C)are enhanced proprietary Type X panels that feature a noncombustible gypsum core that is encased in 100%recycled face and back papers that form a high strength composite design.The face paper is folded around the long edges to reinforce and protect the core,and the ends are cut square and even.The long edges of the panels are tapered,allowing joints to be reinforced and concealed with USG Sheetrock®Brand joint treatment systems.The panels are UL Classified for fire resistance and can be used in any UL Design in which Type C panels are listed.On the face along the long edge of each panel,the UL Type Designation is printed for easy identification by building inspectors. INTENDED FOR • Commercial or residential applications where 1/2 in.(12.7 mm)or 5/8 in.(15.9 mm)Type X or enhanced proprietary Type X panels are required • New or repair and remodel construction • Load-bearing and nonload-bearing wood-or steel-framed fire-rated walls and ceilings LIMITATIONS 1. Avoid exposure to sustained temperatures exceeding 125°F(52°C). 2.Avoid exposure to excessive,repetitive or continuous moisture before,during and after installation.Eliminate sources of moisture immediately. 3. Must be stored off the ground and under cover in accordance with Gypsum Association's GA-801,Handling and Storage of Gypsum Panel Products. INTERIOR INSTALLATION, For maximum framing spacing in non-fire-resistance-rated applications of gypsum panel products, FINISHING AND DECORATING refer to Gypsum Association's GA-216,Specifications for the Application and Finishing of Gypsum INSTALLATION Panel Products or ASTM C840,Standard Specification for Application and Finishing of Gypsum Board. For fire-resistance-rated applications,refer to the published UL Design or GA File Number. Maximum Framing Spacing for Single-Layer Application Location Gypsum Panel Thickness Gypsum Panel Orientation to Framing Maximum Framing Spacing OC Ceilings' 1/2 in.(12.7 mm) Parallel 16 in.(406 mm) Perpendicular 24 in.(610 mm) 5/8 in.(15.9 mm) Parallel 16 in.(406 mm) Perpendicular 24 in.(610 mm) Walls 1/2 in.(12.7 mm) Parallel 24 in.(610 mm) Perpendicular 24 in.(610 mm) 5/8 in.(15.9 mm) Parallel 24 in.(610 mm) Perpendicular 24 in.(610 mm) USG IT'S YOUR WORLD.BUILD IT.° INTERIOR INSTALLATION, Maximum Framing Spacing for Multi-Layer Application Without Adhesive Between Layers FINISHING AND DECORATING,CONT. Location Gypsum Panel Thickness Gypsum Panel Orientation to Framing Maximum Framing Spacing OC INSTALLATION Ceilings' 1/2 in.(12.7 mm) Parallel 16 in.(406 mm) Perpendicular 24 in.(610 mm) 5/8 in.(15.9 mm) Parallel 16 in.(406 mm) Perpendicular 24 in.(610 mm) Walls 1/2 in.(12.7 mm) Parallel 24 in.(610 mm) Perpendicular 24 in.(610 mm) 5/8 in.(15.9 mm) Parallel 24 in.(610 mm) Perpendicular 24 in.(610 mm) Note: 1. On ceilings to receive water-based texture material,1/2 in.(12.7 mm)gypsum board shall be applied perpendicular to framing spaced 16 in.(406 mm)OC;5/8 in.(15.9 mm)gypsum board shall be applied either parallel to framing spaced at 16 in. (406 mm)OC or perpendicular to framing spaced maximum 24 in.(610 mm)OC.See Appendix A.3 of Gypsum Association's GA-216,Specifications for the Application and Finishing of Gypsum Panel Products for more information. FINISHING AND DECORATING For high-quality finishing results,USG recommends USG Sheetrock®Brand finishing products. Painting products and systems should be used that comply with recommendations and requirements in Appendices of ASTM C840.For priming and decorating with paint,texture or wall covering,follow manufacturer's directions for materials used.Gypsum Association's GA-214, Recommended Levels of Finish for Gypsum Board,Glass Mat and Fiber-Reinforced Gypsum Panels should be referred to in order to determine the level of finishing needed to ensure a surface properly prepared to accept the final decoration. All surfaces,including applied joint compound,must be thoroughly dry,dust-free and not glossy. Prime with USG Sheetrock®Brand First Coat'®Primer or with an undiluted,interior latex flat paint with high-solids content.Allow to dry before decorating. To improve fastener concealment where gypsum panel walls and ceilings will be subjected to severe artificial or natural side lighting,or will be decorated with a gloss paint(eggshell,semigloss or gloss),the gypsum panel should be skim coated with joint compound.This equalizes suction and texture differences between the drywall face paper and the finished joint compound before painting.As an alternative to skim coating,or when a Level 5 finish is required,use USG Sheetrock® Brand Tuff-Hide'Primer-Surfacer.See USG She etrock®Brand Tuff-Hidetm Primer-Surfacer Submittal Sheet(J1613)for limitations and application instructions. For more information,refer to USG literature Finishing&Decorating Gypsum Panels White Paper(J2010). TEST DATA Property ASTM Test Requirement ULTypeC 1/2 IN.(12.7 MM) Method Noncombustibillty E136 Noncombustible Meets Surface-burning Flame spread E84 Flame Spread Index,not 15 characteristics greater than 25' Smoke developed E84 — 0 Class A E84 Flame spread not greater Meets than 25 and smoke developed not greater than 450 Core hardness Field C473(B) Not less than 11 Ibf(49 N)2 Meets End C473(B) Not less than 11 Ibf(49 N)2 Meets Edge C473(B) Not less than 11 Ibf(49 N)' Meets Flexural strength Parallel C473(B) Not less than 36 lbf(160 N)' Meets Perpendicular C473(B) Not less than 107 lbf(476 N)' Meets Humidified deflection C473 Not greater than 1-1/4 in. Meets (32 mm)' Nail pull resistance C473(B) Not less than 77 lbf(343 N)' Meets Note: 2.Per ASTM C1396 for 1/2 in.(12.7 mm)gypsum wallboard. TEST DATA,CONT. Property I ASTM Test Requirement UL Type C 5/8 IN.(15.9 MM) Method Noncombustibility E136 Noncombustible Meets Surface-burning Flame spread E84 Flame Spread Index,not 15 characteristics greater than 25 Smoke developed E84 — 0 Class A E84 Flame spread not greater Meets than 25 and smoke developed not greater than 450 Core hardness Field C473(B) Not less than 11 Ibf(49 N)' Meets End C473(B) Not less than 11 Ibf(49 N)' Meets Edge C473(B) Not less than 11 Ibf(49 N)' Meets Flexural strength Parallel C473(B) Not less than 46 lbf(205 N)' Meets Perpendicular C473(B) Not less than 147Ibf(654 N)' Meets Humidified deflection C473 Not greater than 5/8 in. Meets (15.9 mm)' Nail pull resistance C473(B) Not less than 87 lbf(387 N)' Meets Note: 3.Per ASTM C1396 for 5/8 in.(15.9 mm)gypsum wallboard. PRODUCT DATA UL Type C UL Type C PRODUCT INFORMATION Thickness 1/2 in.(12.7 mm) 5/8 in.(15.9 mm) See usg.com for the most up-to-date product information. Lengths' 8-12 ft.(2438-3658 mm) 8-12 ft.(2438-3658 mm) GREENGUARD stanCertified productsrloware i al emissions Width 4 ft.(1219 mm),54 in.(1372 mm) 4 ft.(1219 mm),54 in.(1372 mm) GREENGUARD standards for low chemical emissions into indoor air during product usage.For more information,visit ul.com/gg. Weight',nominal 2.0 lb./sq.ft.(9.8 kg/sq.m.) 2.5 lb./sq.ft.(12.2 kg/sq.m.) CAUTION Edges Tapered Tapered Dust may cause irritation to eyes,skin,nose,throat and upper respiratory tract.Cut and trim with a utility knife Packaging Two panels per bundle Two panels per bundle or hand saw to minimize dust levels.Power tools must be equipped with a dust collection system.Wear eye,skin and Notes: respiratory protection if necessary.If eye contact occurs, 4.Other sizes available by special order.Check with your local USG representative for availability. flush thoroughly with water for 15 minutes.If irritation 5.Represents approximate weight for design shipping persists,call a physician.Do not swallow.If swallowed, pp it i 9 9 pp g purposes.For specific product weight in your area,contact your local call a physician.For more information call Product Safety: USG representative or call the Customer Service Center at 800 950-3839. 800 507-8899 or see the SDS at usg.com. KEEP OUT OF REACH OF CHILDREN. TRADEMARKS COMPLIANC The trademarks USG,FIRECODE,FIRST COAT,SHEETROCK, TUFF-HIDE,IT'S YOUR WORLD.BUILD IT.,the USG • Comply h ASTM C1396 for 1/2 in. 2.7 mm),5/8 in.(15.9 mm)and Type X gypsum wallboard logo,the design elements and colors,and related marks are trademarks of USG Corporation or its affiliates.The • Classified as a lass A rrrroiror inish Material per Section 803.1 of the International Building trademarks IBC and INTERNATIONAL BUILDING CODE are Code®(IBC®) trademarks of International Code Council,Inc. • UL Classification as to fire resistance,surface-burning characteristics and noncombustibility NOTE Products described here may not be available in all • Achieved GREENGUARD Gold Certification and qualifies as a low VOC emitting material(meets geographic markets.Consult your USG Company sales CA 01350) office or representative for information.The information in this document is subject to change without notice.USG Corporation assumes no responsibility for any errors that may inadvertently appear in this document. SUBMITTAL APPROVALS NOTICE We shall not be liable for incidental and consequential Job Name damages,directly or indirectly sustained,nor for any loss caused by application of these goods not in accordance with current printed instructions or for other than the intended Contractor Date use.Our liability is expressly limited to replacement of defective goods.Any claim shall be deemed waived unless made in writing to us within thirty(30)days from date it was or reasonably should have been discovered. SAFETY FIRST! Follow good safety and industrial hygiene practices during handling and installation of all products and systems.Take necessary precautions and wear the appropriate personal protective equipment as needed.Read Safety Data Sheets and related literature on products before specification and/ 800 USG.4YOU or installation. 800(874-4968) usg.com EEC°° USG \ GREENGUARD R United by W2020 USG CorporationoNG/a a 0 °R R° United States Gypsum Company ©2020 USG and/or �"°'•°-'•°°• 550 West Adams Street its affiliates.All rights reserved. Chicago,IL 60661 Printed in U.S.A. IT'S YOUR WORLD.BUILD IT.°