HomeMy WebLinkAboutMaster Permit.215 S Monarch St.0041-2020-BCOM (2) 0042-2020-BCOM_BuildingComments_1
3/16" Scale (1)
File Name: 90.215 S Monarch Planset.20200817.pdf
Author: bonniem 4 7
301'min Subject: 3/16"Scale
Page Label: G-300 ELEVATIONS
Color: •
Y:
27"min 34"Max X:
Creation Date: 11/9/2020 11:53:50 AM
Date: 11/9/2020 11:53:50 AM
T ELEVATION Checkmark: Unchecked
Lock: Unlocked
Status:
Document Width:
Document Height:
Length: 4.58 ft'in"
Unit:ft
Measurement:4.58 ft' in"
Capture: No
Page Index: 3
Space:
Width:
Height:
Rise/Drop:
Area:
Wall Area: 37 sf
Depth: 8.00 ft
Volume:
Count:
PlanCheck (5)
File Name: 90.215 S Monarch Planset.20200817.pdf
Author: bonniem Provide a building/unit
Subject: PlanCheck relationship for this unit. ie:
Page Label: G-200 PROPOSED PLANS where are
Color: • exits?Whatthe is above,restrooms belowand and,
Y: 0.8430 in on either side of this unit? This
will determine whether the walls
• X. 107193 in.
Creation Date: 11/9/2020 11:49:30 AM and ceiling will need to be fire
MIN
-- o Date: 11/9/2020 11:53:08 AM and sound rated.
- _ Checkmark: Unchecked
Lock: Unlocked
Status:
Document Width: 20.3563 in
Document Height: 13.3512 in
Length:
Unit: Count
Measurement: 1 Count
Capture: No
Page Index: 2
Space:
Width:
Height:
Rise/Drop:
Area:
Wall Area:
Depth:
Volume:
Count:
File Name: 90.215 S Monarch Planset.20200817.pdf
O Author: bonniem Microwave needs to be moved
gl
o� so that the operalbe parts are
Subject: PlanCheckL oLLwithin the accessilbe reach
Page Label: G-300 ELEVATIONS
° Color: ■ range(max 48"). (2009 ICC
Y: 9.1823 in A117.1 804.5, 308.2)
X: 22.0261 in
Creation Date: 11/9/2020 11:57:07 AM
Date: 11/9/2020 12:00:24 PM
Checkmark: Unchecked
Lock: Unlocked
Status:
Document Width: 9.6380 in
Document Height: 7.3857 in
Length:
Unit: Count
Measurement: 1 Count
Capture: No
Page Index: 3
Space:
Width:
Height:
Rise/Drop:
Area:
Wall Area:
Depth:
Volume:
Count:
File Name: 90.215 S Monarch Planset.20200817.pdf
Author: bonniem Show where this wall type is to
Subject: PlanCheck be used with wall call outs
Page Label: and/or plan notes.
o= Color: ■
Y: 1.5558 in
X: 2.8911 in
Creation Date: 11/9/2020 2:34:06 PM
Date: 11/9/2020 2:35:23 PM
Checkmark: Unchecked
Lock: Unlocked
Status:
Document Width: 20.0745 in
Document Height: 11.6512 in
Length:
Unit: Count
Measurement: 1 Count
Capture: No
Page Index: 4
Space:
Width:
Height:
Rise/Drop:
Area:
Wall Area:
Depth:
Volume:
Count:
File Name: 90.215 S Monarch Planset.20200817.pdf
This building is Type VA
O DEMO ALL WALL FINISHES T°m"=. Author: bonniem
o s"••a .a"„""E„"�,„ construction, so the new ceiling
Subject: PlanCheck
Page Label: G-100 EXISTING-DEMO PLANS assembly will need to be
Color: • one-hour fire-resistance rated
>A ° E,= °" d"pd.ns° Y: 7.0179 in (and provide an STC rating of at
X: 6.4185 in least 50 if there is residential
Creation Date: 11/9/2020 2:44:28 PM above). Provide a listed/tested
Date: 11/9/2020 2:45:56 PM ceiling assembly.
Checkmark: Unchecked
Lock: Unlocked
Status:
Document Width: 6.6806 in
Document Height: 2.6013 in
Length:
Unit: Count
Measurement: 1 Count
Capture: No
Page Index: 1
Space:
Width:
Height:
Rise/Drop:
Area:
Wall Area:
Depth:
Volume:
Count:
File Name: 30.Lighting Specs.20200806.pdf
Author: bonniem LL-1 runs off a driver. Provide
Subject: PlanCheck the driver spec sheet and adjust
Page Label: 1 the COMcheck so that the
DYNAMIC wattage and number of the
�'a�a,*"''' "." Color: •
Y: 7.1095 in driver(s)is listed rather than the
X: 0.8609 in individual lamps.
�_wwHIo.°.�•omm„°� � .m p Creation Date: 11/9/2020 4:07:57 PM
e�.� Eo ."°•� -•-• �- Date: 11/9/2020 4:11:16 PM
Checkmark: Unchecked
Lock: Unlocked
Status:
Document Width:4.7851 in
Document Height: 2.7865 in
Length:
Unit: Count
Measurement: 1 Count
Capture: No
Page Index: 1
Space:
Width:
Height:
Rise/Drop:
Area:
Wall Area:
Depth:
Volume:
Count: