Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Change Order.100 Dean St.0092-2022-BCHO (3)
MXZ-3C30NA2 MITSUBISHI MULTI-ZONE INVERTER HEAT-PUMP SYSTEM �_ELECTRIC Job Name: System Reference: Date: ARMS" IlIIIIIIIIIIIIIIIIIIII1IIl1luIil 11�; - IlIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIiii itIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII� .�� . �IIIIIIIIIIIIII 01 1IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII11 11 Iiiiii IIIIIIIIIIIIDwo . FEATURES • Variable speed INVERTER-driven compressor • Optional base pan heater • Quiet outdoor unit operation as low as 56 dB(A) • High pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protectionIR sophiev 12/15/2022 ZONING RECEIVED 12/12/2022 Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLCASiFgfaserved. BUILDING DEPARTMENT SPECIFICATIONS: MXZ-3C30NA2 (For data on specific indoor units,see the MXZ-C Technical and Service Manual.) Rated Capacity Btu/h 28,400/27,400 Cooling* Capacity Range Btu/h 9,500-28,400/9,500-27,400 (Non-ducted/Ducted) Rated Total Input W 2,680/2,860 Rated Capacity Btu/h 28,600/27,600 Heating at 47°F* Capacity Range Btu/h 15,500-36,000/15,500-35,000 (Non-ducted/Ducted) Rated Total Input W 2,150/2,220 Heating at 17°F' Rated Capacity Btu/h 16,000/15,100 (Non-ducted/Ducted) Rated Total Input W 2,120/2,140 Connectable Capacity 12,000-36,000 Power Supply Voltage,Phase,Hertz 208/230V,1-Phase,60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 25 MCA A 22.1 Indoor-Outdoor S1-S2 V AC 2 /230 Voltage Indoor-Outdoor S2-S3 V DC±24 Compressor INVERTER-driven Scroll Hermetic Fan Motor(ECM) F.L.A. Mr 2.43 Cooling dB(A) 52 Sound Pressure Level Heating dB(A) 56 In 31-11/32 x 37-13/32 x 13 External Dimensions(H x W x D) mm (796 x 950 x 330) Net Weight Lbs/kg 137(62) External Finish Munsell No.3Y 7.8/11 i Liquid(High Pressure) In/mm 1/4(12.7) Refrigerant Pipe Size O.D. Gas(Low Pressure) In/mm A:1/2(6.35);B,C:3/8(9.52) Max.Refrigerant Line Length 230(70) Max.Piping Length for Each Indoor Unit Ft/m 82(25) Max. Pipe Height If IDU is Above ODU Ft/m 49(15) DifferenRefrigerantce If IDU is Below ODUNAM Ft/mAIL 49(15) Connection Method Flared/Flared Refrigerant R410A *Rating Conditions perAHRI Standard: Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB Heating at 47°F I Indoor:70°F(21°C)DB Heating at 17°F I Indoor:70°F(21°C)DB Cooling I Outdoor:95°F(35°C)DB/75°F(24°C)WB Heating at 47°F I Outdoor:47°F(8°C)DB/43°F(6°C)WB Heating at 17°F I Outdoor:17°F(-8°C)DB/15°F(-9°C)WB OPERATING RANGE: ENERGY EFFICIENCIES: Outdoor Indoor Unit Type SEER EER HSPF COP @ 47°F COP @ 17°F Cooling 14 to 115°F(-10 to 46°C)DB Non-ducted 19.0 10.6 10.6 3.90 2.77 (09+09+12) Heating 5 to 65°F(-15 to 18°C)WE Ducted and Non ducted 17.6 10.1 10.1 3.77 2.78 Ducted 16.2 9.6 9.6 3.64 2.78 (09+09+12) NOTES: For actual capacity performance based on indoor unit type and number of indoor units connected,please refer to MXZ Operational Performance. Although the maximum connectable capacity can exceed rated,the outdoor unit cannot provide more than 100%of the rated capacity.Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. RECEIVED 12/12/2022 Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC! iWt gM t served. BUILDING DEPARTMENT OUTDOOR UNIT ACCESSORIES: MXZ-3C30NA2 Air Outlet Guide Air Outlet Guide(1 Piece) 0 PAC-SH96SG-E Refrigeration Ball Valve-1/2" 0 BV12FFSI2 Refrigeration Ball Valve-1/4" ❑ BV14FFSI2 Ball Valve Refrigeration Ball Valve-3/8" ❑ BV38FFSI2 Refrigeration Ball Valve-5/8" ❑ BV58FFSI2 Distribution pipe for Branch Box M-NET Converter 0 PAC-IF01 MNT-E Drain Socket Drain Socket 0 PAC-SG60DS-E Hail Guards Hail Guard 0 HG-A9 Condensing Unit Mounting Pad:16"x 36"x 3" 0 ULTRILITE1 Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic 0 DSD-400P Optional Defrost Heater Base Heater 0 PAC-645BH-E Adaptor:1/2"x 3/8" 0 MAC-A455JP-E Adaptor:1/2"x 5/8" 0 MAC-A456JP-E Port Adapter Adaptor:3/8"x 1/2" 0 MAC-A454JP-E Adaptor:3/8"x 5/8" 0 PAC-SG76RJ-E Power Supplies and Auxiliary Components M-Net Control Wire,1,000'Roll(16-AWG,Standard,Twisted Pair,Shielded,Jacketed-Plenum rated) ❑ CW162S-1000 Power Supplies And Auxiliary Components M-Net Control Wire,250'Roll(16-AWG,Standard,Twisted Pair,Shielded,Jacketed-Plenum rated) 0 CW162S-250 18"Single Fan Stand 0 QSMS1801 M 24"Single Fan Stand 0 QSMS2401 M Stand Condenser Wall Bracket 0 QSWB2000M-1 Condenser Wall Bracket-Stainless Steel Finish 0 QSWBSS Outdoor Unit Stand—12"High 0 QSMS1201 M RECEIVED 12/12/2022 Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC!ASi gfaserved. BUILDING DEPARTMENT OUTDOOR UNIT DIMENSIONS: MXZ-3C3ONA2 Unit: inch 6-7/8" 23-5/8' .-7/8' Rear Ao- ore 2-13/16' 1/16" 4-19/32' 2-1/32' EN 2-U Sha.ed Notched Hole 13/32" (Foundation Bolt M10) NI SEMI �� a Side Air minks b m Z.N � m b 6-01-5/16'Drain Hole Air N 113/32' iv boemnr9e 13/32' 2-(15/32'X1-13/32')Oval Hole 1-1/32 2-07/8"knockout hole (Foundation Bolt M10) 1-1/2' I (Connectin• wire hole) 1-5/8' II 37-13/32" . 31/32' 13' 19/32' 3-®7/8'punched hole II (Connecting wire hole) Handle .._. \ m III I Handle Y l l� Handle • Ill •• Hontlle ' —10 I .�- _ i I IIlIllllll lllllllullliill� II 4�lli �� ! I I IIIIIIIIIIIIIIIIIVIIIIIIII,PJIIIIIIIII'!I 11112_3/4" .n ----z -- i� IIIIIIIIIIIullllll jllllllllllllllll I R I Allll I I Air Intake 0 11IlIIIIIIIIIIIIW41111VIlpPsllllll ovllll AILI....,dlllinmmnllr'I Ii !' � L1° uno cI GA5 1�aAaS 1 unlr eJ 6A5}Unit A GAS 1/2't023]IIF LARE '7 11-11/32' — 14-7/32° 1.FREE SPACE E E E 3-15/16' or more 1°11 a 0 0 3-15/16" or more 13-25/32' or more Ism. Conduit plates liziffitP J Conduit connector 2.SERVICE SPACE v e EarN� �� ..;i, i. Lock nut 3-15/16' or more SERVICE SPACE 13-25/32' or more 13-25/32' or more 1340 Satellite Boulevard Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com LO rim......l CEI7 IE, r L...,.. 11W,,s � FORM#M_SUBMITTAL_MXZ-3C30NA2_en-202108 /1 721(022 Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC!AiNigMte iJserved. :3UILDING DEPARTMENT