Loading...
HomeMy WebLinkAboutMaster Permit.809 S Aspen St.0005-2021-BRES (13) e e rn e n t ENVIRONMENTAL INC 189 County Rd. 135 Glenwood Springs, CO 81601 josh@elementconsults.com (970) 274-3139 Property Address Asbestos Sampling Report 809 S. Aspen St. Date: 06/30/2021 Aspen, CO 81611 H Date of Inspection: 06/29/2021 Client: Element Environmental Project#: Shadow Mountain 062921 Unit A a) Shadow Mountain HOA E Client Job Name a) Shadow Mountain Unit A Attn: °hillip Ring TABLE OF CONTEIN I S 1.0 -Scope of Work O 2.0 -Sampling Requirements Q 3.0 -Sampling Methodology °C 4.0 - Laboratory 0 Building Inspector: N 5.0 -Suspect Materials Sampled Ellen Johnson 6.0 -Table of Results 7.0 - Description of Sampling Area CDPHE#23799 8.0 - Conclusion 9.0 - Lab Report 10.0 - Certificates Joshua Johnson CDPHE#18401 Asbestos Samples Analyzed: 3 Positive Asbestos Samples: 0 RECEIVED 11/12/2021 ASPEN BUILDING DEPARTMENT 2 1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel. Element Environmental conducted a visible inspection for visible materials that would be impacted during the remodel. This inspection was limited to the areas found in the Description of the Sampling Area 7.0. Although sampling is destructive in nature, this was a non-invasive inspection. It was of materials that were accessible. If other suspect materials become visible/apparent during demolition or construction activities, work in that area should be halted and more sampling/testing must take place, per Colorado regulations. Any suspect materials that were not tested are to be assumed to contain asbestos. 2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with Colorado State Requirements. The minimum number of samples per homogenous areas are as follows: 2.1-Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples 1,000 sq.ft.-5,000sq.ft.- Minimum of 5 samples >5,000 sq.ft. Minimum of 7 samples 2.2-Miscellaneous materials- Minimum of 2 samples 2.3-Thermal Systems Insulation(ISO- Minimum of 3 samples 3.0- The purpose of the inspection is to identify materials that are homogenous. A homogeneous area is defined as one which shares suspect material, texture, color, location, and/or apparent time of construction. The materials are segregated into separate homogenous areas. The size is determined and then samples are taken. The materials are touched to determine friability. Friable ACM is material that can be crushed or reduced to powder by hand pressure. The samples are taken in a random numerical sequence. 4.0- Ellen Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 23799, performed the inspection. The findings were reviewed by Josh Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 18401. Samples taken were sent to CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be trace, or<1% asbestos, is considered to be ACM material. This material would still be a regulated material by CDPHE. The sample must have an additional "point count" performed to be considered less than 1% and not be regulated by the CDPHE. The lab's documents with analyses and findings are found below. RECEIVED e e m e n t 18g county rd 135 gLenwood springs,co 8i6o1 g7G.2743139 121 www.elementconsults.com Project#-Shadow Mtn 062921 ENVIRONMENTAL INC LEAD ASBESTOS H �i• ?BUILD' 1 •'-iTMENT 3 5.0- SUSPECT MATERIALS SAMPLES • Drywall • Joint Compound • Texture • Tape 6.0- TABLE OF RESULTS HOMOGENOUS DESCRIPTION OF AREA ACM CATEGORY NUMBER APPROXIMATE ACM ASSESSMENT CATEGORIES %AND TYPE OF AREA OF SQ.FT.* ASBESTOS FOUND SAMPLES (A) Orange Peel Texture on walls Surfacing 3 —200 sq.ft. Friable Non-ACM No Asbestos Detected Key: ACM Assessment Categories: 1-Damaged or significantly damaged Thermal Systems Insulation 6-ACM with potential for significant damage (TSI)ACM 7-Friable ACM with low potential for damage 2-Damaged friable surfacing ACM Other-ACM not classified in the above Assessment Categories 3-Significantly damaged friable Surfacing ACM N/A-Not Applicable 4-Damaged or significantly damaged friable Miscellaneous ACM 5-ACM with potential for damage *Square footage is estimated and not for bidding purposes 7.0- DESCRIPTION OF SAMPLING AREA • The Orange Peel Texture on the laundry room walls for a remodel 8.0- CONCLUSION No asbestos was detected in any of the samples taken. Sincerely, Ellen Johnson RECEIVED e e rn e n t 189 county rd 135 gLenwood springs,co 8i6o1 970.2743139 )21 www.elementconsults.com Project#-Shadow Mtn 062921 ENVIRONMENTAL INC LEAD ASBESTOS H T �i' LDI 1 •cTMENT 4 9.0- LAB REPORT tiff eurofins CEI ASBESTOS ANALYTICAL REPORT By: Polarized Light Microscopy Prepared for Element Environmental LLC CLIENT PROJECT: Keelfy 062921 Unit A LAB CODE: A219142 TEST METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 REPORT DATE: 06/30/21 TOTAL SAMPLES ANALYZED: 3 #SAMPLES>1%ASBESTOS: e e m en - 18g county rd 135 gLenwood springs,co 816( ' :'c 274. c EDwwvw.elementconsults.com Project#-Shadow Mtn 062921 ENVIRONMENTAL INC LEAD ASBESTOS HAZII T S R T 1�1��n21 ASPEN BUILDING DEPARTMENT 5 Asbestos Report Summary ti•• eurofins By: POLARIZING LIGHT MICROSCOPY CEI PROJECT: Keelfy 062921 Unit A LAB CODE: A219142 METHOD: EPA 600/R93/ 116 and EPA 600/ M4-82/020 ASBESTOS Client ID Layer Lab ID Color Sample Description 809A Al Layer 1 A128639 White Orange Peel Texture None Detected Layer 2 A128639 White Sheetrock None Detected 809A A2 Layer 1 A128640 White Orange Peel Texture None Detected Layer 2 A128640 White Sheetrock None Detected 809A A3 Layer 1 A128641 White Orange Peel Texture None Detected Layer 2 A128641 White Sheetrock None Detected Page 1 of 1 e e m e n - 189 county rd 135 glen wood springs,co 816( ' 70 274 "�c E D wwvw.elementconsults.com 6c�/ Project#-Shadow Mtn 062921 ENVIRONMENTAL INC LEAD ASBESTOS NAZ"i T S R T 1f�1��21321 ASPEN BUILDING DEPARTMENT 6 tiff° eurofins • ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY CE I Client: Element Environmental LLC Lab Code: A219142 189 CR 135 Date Received: 06-30-21 Glenwood Springs, CO 81601 Date Analyzed: 06-30-21 Date Reported: 06-30-21 Project: Keelfy 062921 Unit A ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non-Fibrous 809A Al Orange Peel Texture Heterogeneous 5% Paint None Detected Layer 1 White 40% Binder A128639 Non-fibrous 55% Calc Carb Bound Layer 2 Sheetrock Heterogeneous 10% Cellulose 90% Gypsum None Detected A128639 White Fibrous Bound 809A A2 Orange Peel Texture Heterogeneous 5% Paint None Detected Layer 1 White 40% Binder A128640 Non-fibrous 55% Calc Carb Bound Layer 2 Sheetrock Heterogeneous 10% Cellulose 90% Gypsum None Detected A128640 White Fibrous Bound 809A A3 Orange Peel Texture Heterogeneous 5% Paint None Detected Layer 1 White 40% Binder A128641 Non-fibrous 55% Calc Carb Bound Layer 2 Sheetrock Heterogeneous 10% Cellulose 90% Gypsum None Detected A128641 White Fibrous Bound Page 1 of 2 e e m en - 18g county rd 135 Genwood springs,co 816( ' :'c 274, c E ID www.elementconsults.com ��ww Project#-Shadow Mtn 062921 ENVIRONMENTAL INC LEAD ASBESTOS HAI T S R T "'�1f1���b21 ASPEN BUILDING DEPARTMENT 7 eurofins CEI LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb =Calcium Carbonate METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 REPORTING LIMIT: <1%by visual estimation REPORTING LIMIT FOR POINT COUNTS: 0.25%by 400 Points or 0.1%by 1,000 Points REGULATORY LIMIT: >1%by weight Due to the limitations of the EPA 600 method, nonfriable organically bound materials(NOBs)such as vinyl floor tiles can be difficult to analyze via polarized light microscopy(PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request. This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government. Information provided by customer includes customer sample ID and sample description. ANALYST: APPROVED BY: 16,.,,, A- Gt'eg Ru ' Tianbao Bai,Ph.D.,CIH Laboratory Director NVIAp TESTING NVLAP LAB CODE 101768-0 Page2of2 e e m en - 189 county rd 135 glenwood springs,co 816( ' :'c 274. E www.elementconsults.com 666ccc Project#-Shadow Mtn 062921 ENVIRONMENTAL 'dC LEAD ASBESTOS HAZ T S R T "'�lf�l���b21 ASPEN BUILDING DEPARTMENT 8 10.0- CERTIFICATES r n ` fr ' y '`v J 4* • .1"'I. s 4 ,..E ,ar I t';',- i''; ' '"' :,..::_,,,,,,e,i..:,..:,, '�. at, .. ,, ,Colorado Department •':t Colorado Department ! oF Public ronmen a.'r j tr nod ho,�H [h �:' and Environment [ �" CERTIIrATION F ( ASBESTOS * CERTIFICATION* }� •.:! { This"lithos that r, lf r• this certifies that , Ellen Johnson .h, Joshua Jay Johnson ,j �` Certification No.:23799 Air No.t 00401 1 has met the requirements 01'25.7-507,C R S.and Air Quabn Control has met the requirements of 25-7-507,C.R.S.and Air Quality Control -.* a commission Regulation No R,Part B,and,s hereby certified by the o Commission Regulation No S,fart B,and is hereby certified by the :, I ( state of Colorado m the following discipline ,-rr state of Colorado in the following discipline. Building Inspector* Building Inspector* ' _ } .I. ed: July OS,2021 Issued: August21,2020 . I July IY,2021 Aire: Expires: August 01,2021 1 '`'' t- sf .,« tea b.n r . as .. L maI➢J010s11 io ,E. si , I';` '`rY t1��, +r rti` ma's '�..: `s'•��x.. ."...:.• � li!,1• -4� A?C�" `�•t,?Si �',:J, y.. , ,. ED • ColoradoDnpotr�t '•°4of Public Health and Environment ASBESTOS CONSULTING FIRM <; This certifies that Element Environmental LLC lir.›.-:, Registration No.:ACE-21640 #..-�, has met the registration requirements of 25-7-507,C.R.S.and the Air Quality Control 1 Regulation No.8,Part II,and is hereby Commission Rea it SY ulhor cd to perform asbestos-consulting activities as required under Regulation No S,Part B,in the state of Colorado. -, Issued: January 07,2021 �;' Expires: January 25,2022 #�' {. t V wiiaaea,wco wcnr r3:�� ', e e m e n 18g county rd 135 glenwood springs,co 8161 ' :'c 274. -�c EE www.elementconsults.com Project#-Shadow Mtn 062921 ENVIRONMENTAL INC LEAD ASBESTOS DAVIT]. S R T "�1f�1��2t)21 ASPEN BUILDING DEPARTMENT