HomeMy WebLinkAboutMaster Permit.809 S Aspen St.0005-2021-BRES (13) e e rn e n t
ENVIRONMENTAL INC
189 County Rd. 135
Glenwood Springs, CO 81601
josh@elementconsults.com
(970) 274-3139
Property Address
Asbestos Sampling Report 809 S. Aspen St.
Date: 06/30/2021 Aspen, CO 81611
H
Date of Inspection: 06/29/2021
Client:
Element Environmental Project#:
Shadow Mountain 062921 Unit A
a) Shadow Mountain HOA
E Client Job Name
a)
Shadow Mountain Unit A
Attn:
°hillip Ring TABLE OF CONTEIN I S
1.0 -Scope of Work
O 2.0 -Sampling Requirements
Q 3.0 -Sampling Methodology
°C 4.0 - Laboratory
0 Building Inspector:
N 5.0 -Suspect Materials Sampled
Ellen Johnson 6.0 -Table of Results
7.0 - Description of Sampling Area
CDPHE#23799 8.0 - Conclusion
9.0 - Lab Report
10.0 - Certificates
Joshua Johnson
CDPHE#18401 Asbestos Samples Analyzed: 3
Positive Asbestos Samples: 0
RECEIVED
11/12/2021
ASPEN
BUILDING DEPARTMENT
2
1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel.
Element Environmental conducted a visible inspection for visible materials that would
be impacted during the remodel. This inspection was limited to the areas found in the
Description of the Sampling Area 7.0. Although sampling is destructive in nature, this
was a non-invasive inspection. It was of materials that were accessible. If other suspect
materials become visible/apparent during demolition or construction activities, work in
that area should be halted and more sampling/testing must take place, per Colorado
regulations. Any suspect materials that were not tested are to be assumed to contain
asbestos.
2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with
Colorado State Requirements. The minimum number of samples per homogenous areas
are as follows:
2.1-Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples
1,000 sq.ft.-5,000sq.ft.- Minimum of 5 samples
>5,000 sq.ft. Minimum of 7 samples
2.2-Miscellaneous materials- Minimum of 2 samples
2.3-Thermal Systems Insulation(ISO- Minimum of 3 samples
3.0- The purpose of the inspection is to identify materials that are homogenous. A
homogeneous area is defined as one which shares suspect material, texture, color,
location, and/or apparent time of construction. The materials are segregated into
separate homogenous areas. The size is determined and then samples are taken. The
materials are touched to determine friability. Friable ACM is material that can be
crushed or reduced to powder by hand pressure. The samples are taken in a random
numerical sequence.
4.0- Ellen Johnson, a Colorado Department of Public Health & Environment certified building
inspector, certification number: 23799, performed the inspection. The findings were
reviewed by Josh Johnson, a Colorado Department of Public Health & Environment
certified building inspector, certification number: 18401. Samples taken were sent to
CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light
Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be
trace, or<1% asbestos, is considered to be ACM material. This material would still be a
regulated material by CDPHE. The sample must have an additional "point count"
performed to be considered less than 1% and not be regulated by the CDPHE. The lab's
documents with analyses and findings are found below.
RECEIVED
e e m e n t 18g county rd 135 gLenwood springs,co 8i6o1 g7G.2743139
121
www.elementconsults.com
Project#-Shadow Mtn 062921 ENVIRONMENTAL INC LEAD ASBESTOS H �i•
?BUILD' 1 •'-iTMENT
3
5.0- SUSPECT MATERIALS SAMPLES
• Drywall • Joint Compound
• Texture
• Tape
6.0- TABLE OF RESULTS
HOMOGENOUS DESCRIPTION OF AREA ACM CATEGORY NUMBER APPROXIMATE ACM ASSESSMENT CATEGORIES %AND TYPE OF
AREA OF SQ.FT.* ASBESTOS FOUND
SAMPLES
(A) Orange Peel Texture on walls Surfacing 3 —200 sq.ft. Friable Non-ACM No Asbestos Detected
Key:
ACM Assessment Categories:
1-Damaged or significantly damaged Thermal Systems Insulation 6-ACM with potential for significant damage
(TSI)ACM 7-Friable ACM with low potential for damage
2-Damaged friable surfacing ACM Other-ACM not classified in the above Assessment Categories
3-Significantly damaged friable Surfacing ACM N/A-Not Applicable
4-Damaged or significantly damaged friable Miscellaneous ACM
5-ACM with potential for damage *Square footage is estimated and not for bidding purposes
7.0- DESCRIPTION OF SAMPLING AREA
• The Orange Peel Texture on the laundry room walls for a remodel
8.0- CONCLUSION
No asbestos was detected in any of the samples taken.
Sincerely,
Ellen Johnson
RECEIVED
e e rn e n t 189 county rd 135 gLenwood springs,co 8i6o1 970.2743139
)21
www.elementconsults.com
Project#-Shadow Mtn 062921 ENVIRONMENTAL INC LEAD ASBESTOS H T
�i'
LDI 1 •cTMENT
4
9.0- LAB REPORT
tiff eurofins
CEI
ASBESTOS ANALYTICAL REPORT
By: Polarized Light Microscopy
Prepared for
Element Environmental LLC
CLIENT PROJECT: Keelfy 062921 Unit A
LAB CODE: A219142
TEST METHOD: EPA 600/R93/116 and EPA 600/M4-82/020
REPORT DATE: 06/30/21
TOTAL SAMPLES ANALYZED: 3
#SAMPLES>1%ASBESTOS:
e e m en - 18g county rd 135 gLenwood springs,co 816( ' :'c 274. c EDwwvw.elementconsults.com
Project#-Shadow Mtn 062921 ENVIRONMENTAL INC LEAD ASBESTOS HAZII T S R T
1�1��n21
ASPEN
BUILDING DEPARTMENT
5
Asbestos Report Summary
ti•• eurofins By: POLARIZING LIGHT MICROSCOPY
CEI
PROJECT: Keelfy 062921 Unit A LAB CODE: A219142
METHOD: EPA 600/R93/ 116 and EPA 600/ M4-82/020
ASBESTOS
Client ID Layer Lab ID Color Sample Description
809A Al Layer 1 A128639 White Orange Peel Texture None Detected
Layer 2 A128639 White Sheetrock None Detected
809A A2 Layer 1 A128640 White Orange Peel Texture None Detected
Layer 2 A128640 White Sheetrock None Detected
809A A3 Layer 1 A128641 White Orange Peel Texture None Detected
Layer 2 A128641 White Sheetrock None Detected
Page 1 of 1
e e m e n - 189 county rd 135 glen wood springs,co 816( ' 70 274 "�c E D
wwvw.elementconsults.com 6c�/
Project#-Shadow Mtn 062921 ENVIRONMENTAL INC LEAD ASBESTOS NAZ"i T S R T
1f�1��21321
ASPEN
BUILDING DEPARTMENT
6
tiff° eurofins • ASBESTOS BULK ANALYSIS
By: POLARIZING LIGHT MICROSCOPY
CE I
Client: Element Environmental LLC Lab Code: A219142
189 CR 135 Date Received: 06-30-21
Glenwood Springs, CO 81601 Date Analyzed: 06-30-21
Date Reported: 06-30-21
Project: Keelfy 062921 Unit A
ASBESTOS BULK PLM, EPA 600 METHOD
Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS
Lab ID Description Attributes Fibrous Non-Fibrous
809A Al Orange Peel Texture Heterogeneous 5% Paint None Detected
Layer 1 White 40% Binder
A128639 Non-fibrous 55% Calc Carb
Bound
Layer 2 Sheetrock Heterogeneous 10% Cellulose 90% Gypsum None Detected
A128639 White
Fibrous
Bound
809A A2 Orange Peel Texture Heterogeneous 5% Paint None Detected
Layer 1 White 40% Binder
A128640 Non-fibrous 55% Calc Carb
Bound
Layer 2 Sheetrock Heterogeneous 10% Cellulose 90% Gypsum None Detected
A128640 White
Fibrous
Bound
809A A3 Orange Peel Texture Heterogeneous 5% Paint None Detected
Layer 1 White 40% Binder
A128641 Non-fibrous 55% Calc Carb
Bound
Layer 2 Sheetrock Heterogeneous 10% Cellulose 90% Gypsum None Detected
A128641 White
Fibrous
Bound
Page 1 of 2
e e m en - 18g county rd 135 Genwood springs,co 816( ' :'c 274, c E ID
www.elementconsults.com ��ww
Project#-Shadow Mtn 062921 ENVIRONMENTAL INC LEAD ASBESTOS HAI T S R T
"'�1f1���b21
ASPEN
BUILDING DEPARTMENT
7
eurofins
CEI
LEGEND: Non-Anth = Non-Asbestiform Anthophyllite
Non-Trem = Non-Asbestiform Tremolite
Calc Carb =Calcium Carbonate
METHOD: EPA 600/R93/116 and EPA 600/M4-82/020
REPORTING LIMIT: <1%by visual estimation
REPORTING LIMIT FOR POINT COUNTS: 0.25%by 400 Points or 0.1%by 1,000 Points
REGULATORY LIMIT: >1%by weight
Due to the limitations of the EPA 600 method, nonfriable organically bound materials(NOBs)such as
vinyl floor tiles can be difficult to analyze via polarized light microscopy(PLM). EPA recommends that
all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission
Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is
not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on
request.
This report relates only to the samples tested or analyzed and may not be reproduced, except in full,
without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding
the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Samples were received in
acceptable condition unless otherwise noted. This report may not be used by the client to claim
product endorsement by NVLAP or any other agency of the U.S. Government.
Information provided by customer includes customer sample ID and sample description.
ANALYST: APPROVED BY: 16,.,,, A-
Gt'eg Ru ' Tianbao Bai,Ph.D.,CIH
Laboratory Director
NVIAp
TESTING
NVLAP LAB CODE 101768-0
Page2of2
e e m en - 189 county rd 135 glenwood springs,co 816( ' :'c 274. E
www.elementconsults.com 666ccc
Project#-Shadow Mtn 062921 ENVIRONMENTAL 'dC LEAD ASBESTOS HAZ T S R T
"'�lf�l���b21
ASPEN
BUILDING DEPARTMENT
8
10.0- CERTIFICATES
r n ` fr ' y '`v J 4* • .1"'I. s 4 ,..E ,ar
I t';',- i''; ' '"' :,..::_,,,,,,e,i..:,..:,,
'�. at, .. ,, ,Colorado Department •':t Colorado Department
! oF Public
ronmen a.'r j tr nod ho,�H [h �:'
and Environment [
�" CERTIIrATION F ( ASBESTOS
* CERTIFICATION*
}� •.:!
{ This"lithos that r, lf r• this certifies that
, Ellen Johnson
.h, Joshua Jay Johnson ,j
�` Certification No.:23799
Air No.t 00401
1 has met the requirements 01'25.7-507,C R S.and Air Quabn Control
has met the requirements of 25-7-507,C.R.S.and Air Quality Control -.* a commission Regulation No R,Part B,and,s hereby certified by the
o Commission Regulation No S,fart B,and is hereby certified by the :, I ( state of Colorado m the following discipline
,-rr state of Colorado in the following discipline.
Building Inspector*
Building Inspector* '
_ } .I. ed: July OS,2021
Issued: August21,2020 . I July IY,2021 Aire:
Expires: August 01,2021 1 '`'' t-
sf .,« tea b.n r . as .. L
maI➢J010s11 io
,E.
si , I';` '`rY t1��, +r rti` ma's '�..: `s'•��x.. ."...:.• � li!,1• -4� A?C�" `�•t,?Si �',:J,
y.. , ,.
ED
•
ColoradoDnpotr�t '•°4of Public Health
and Environment
ASBESTOS CONSULTING FIRM <;
This certifies that
Element Environmental LLC
lir.›.-:,
Registration No.:ACE-21640 #..-�,
has met the registration requirements of 25-7-507,C.R.S.and the Air Quality Control 1
Regulation No.8,Part II,and is hereby
Commission Rea it
SY ulhor cd to perform asbestos-consulting
activities as required under Regulation No S,Part B,in the state of Colorado. -,
Issued: January 07,2021
�;' Expires: January 25,2022 #�'
{. t V wiiaaea,wco wcnr r3:�� ',
e e m e n 18g county rd 135 glenwood springs,co 8161 ' :'c 274. -�c EE
www.elementconsults.com
Project#-Shadow Mtn 062921 ENVIRONMENTAL INC LEAD ASBESTOS DAVIT]. S R T
"�1f�1��2t)21
ASPEN
BUILDING DEPARTMENT