HomeMy WebLinkAboutMaster Permit.215 S Monarch St.0041-2020-BCOM (5) e e rn e n t
ENVIRONMENTAL INC
189 County Rd. 135
Glenwood Springs, CO 81601
josh@elementconsults.com
(970) 274-3139
Property Address
Asbestos Sampling Report 215 S. Monarch St. #103
Date: 01/11/2020 Aspen, CO 81611
Date of Inspection: 01/07/2020
o Client: Element Environmental Project#:
t) Ford 010720 Monarch
John Ford
cu
Attn:
Client Job Name
John Ford Monarch Office
TABLE OF CONTENTS
Building Inspector: 1.0 - Scope of Work
2.0 - Sampling Requirements
Ellen Johnson 3.0 - Sampling Methodology
4.0 - Laboratory
CDPHE#23799 5.0 -Suspect Materials Sampled
6.0 -Table of Results
7.0 - Description of Sampling Area
Joshua Johnson 8.0 -Conclusion
9.0 - Lab Report
CDPHE#18401 10.0 -Certificates
Asbestos Samples Analyzed: 5
Positive Asbestos Samples: 0
I1KE IVE D
08/17/2020
ASPEN
BUILDING DEPARTMENT
2
1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel.
Element Environmental conducted a visible inspection for visible materials that would
be impacted during the remodel. This inspection was limited to the areas found in the
Description of the Sampling Area 7.0. Although sampling is destructive in nature, this
was a non-invasive inspection. It was of materials that were accessible. If other suspect
materials become visible/apparent during demolition or construction activities, work in
that area should be halted and more sampling/testing must take place, per Colorado
regulations. Any suspect materials that were not tested are to be assumed to contain
asbestos.
2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with
Colorado State Requirements. The minimum number of samples per homogenous areas
are as follows:
2.1-Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples
1,000 sq.ft.-5,000sq.ft.- Minimum of 5 samples
>5,000 sq.ft. Minimum of 7 samples
2.2-Miscellaneous materials- Minimum of 2 samples
2.3-Thermal Systems Insulation(TSI)- Minimum of 3 samples
3.0- The purpose of the inspection is to identify materials that are homogenous. A
homogeneous area is defined as one which shares suspect material, texture, color,
location, and/or apparent time of construction. The materials are segregated into
separate homogenous areas. The size is determined and then samples are taken. The
materials are touched to determine friability. Friable ACM is material that can be
crushed or reduced to powder by hand pressure. The samples are taken in a random
numerical sequence.
4.0- Ellen Johnson, a Colorado Department of Public Health & Environment certified building
inspector, certification number: 23799, performed the inspection. The findings were
reviewed by Josh Johnson, a Colorado Department of Public Health & Environment
certified building inspector, certification number: 18401. Samples taken were sent to
CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light
Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be
trace, or<1% asbestos, is considered to be ACM material. This material would still be a
regulated material by CDPHE. The sample must have an additional "point count"
performed to be considered less than 1% and not be regulated by the CDPHE. The lab's
documents with analyses and findings are found below.
RECEIVED
i89 count rd 135 glenwood springs,co 816o1 970.274 3,39 /2 0 2 0
e e rn e n t y
www.etementconsults.com
Project#-Ford 010720 Monarch ENVIRONMENTAL!NC LEAD ASBESTOS HAZMAT A1 EN
Pl��O PARTMENT
3
5.0- SUSPECT MATERIALS SAMPLES
• Drywall • Joint Compound
• Texture • Carpet and Mastic
• Tape
6.0- TABLE OF RESULTS
HOMOGENOUS DESCRIPTION OF AREA ACM CATEGORY NUMBER APPROXIMATE ACM ASSESSMENT CATEGORIES %AND TYPE OF
AREA OF SQ.FT.* ASBESTOS FOUND
SAMPLES
(A) Skip Trowel Texture Surfacing 3 250 sq.ft. Friable Non-ACM No Asbestos Detected
(B) Carpet and Mastic Miscellaneous 2 "250 sq.ft. Non-Friable Non-ACM No Asbestos Detected
Key:
ACM Assessment Categories:
1-Damaged or significantly damaged Thermal Systems Insulation 6-ACM with potential for significant damage
(TSI)ACM 7-Friable ACM with low potential for damage
2-Damaged friable surfacing ACM Other-ACM not classified in the above Assessment Categories
3-Significantly damaged friable Surfacing ACM N/A-Not Applicable
4-Damaged or significantly damaged friable Miscellaneous ACM
5-ACM with potential for damage *Square footage is estimated and not for bidding purposes
7.0- DESCRIPTION OF SAMPLING AREA
• The Skip Trowel Texture in the Office
• The Carpet and Mastic in the Office
8.0- CONCLUSION
No asbestos was detected in any of the samples taken.
Sincerely,
Ellen Johnson
RECEIVED
i89 count rd t35 glenwood springs,co 816o1 970.274.3139 /2 0 2 0
e e rn e n t y
www.etementconsults.com
EN
Project#-Ford 010720 Monarch ENVIRONMENTAL!NC LEAD ASBESTOS HAZMAT PARTMENT
BUHREU � PA
4
9.0- LAB REPORT
tiff eurofins
CEI
ASBESTOS ANALYTICAL REPORT
By: Polarized Light Microscopy
Prepared for
Element Environmental LLC
CLIENT PROJECT: Ford 010720 Monarch, 2155 Monarch
LAB CODE: 6A200030
TEST METHOD: EPA 600/R93/116 and EPA 600/M4-82/020
REPORT DATE: 01/10/20
TOTAL SAMPLES ANALYZED: 5
#SAMPLES>1%ASBESTOS:
TOTAL LAYERS ANALYZED: 13
e e m e n t 189 county rd 135 glenwood springs,co 81601 g ^ '31 39 IVE
www.elementconsults.com
Project#-Ford 010720 Monarch ENVIRONMENTAL INC LEAD ASBESTOS HAZMAT B
6§f"�I
`�/2020
ASPEN
BUILDING DEPARTMENT
5
eurofins Asbestos Report Summary
.• By: POLARIZING LIGHT MICROSCOPY
CEI
PROJECT: Ford 010720 Monarch, 2155 Monarch LAB CODE: 6A200030
METHOD: EPA 600/R93/116 and EPA 600/M4-82/020
IASBESTOS
Client ID Layer Lab ID Color Sample Description
103 Al Layer 1 F196520 Gray.White Skip Trowel Texture None Detected
Layer 2 F196520 Off-white Joint Compound None Detected
Layer 3 F196520 Tan,Gray Drywall None Detected
103 A2 Layer 1 F196521 Gray,White Skip Trowel Texture None Detected
Layer 2 F196521 Off-white Joint Compound None Detected
Layer 3 F196521 Tan,Gray Drywall None Detected
103 A3 Layer 1 F196522 Gray,White Skip Trowel Texture None Detected
Layer 2 F196522 Off-white, Joint Compound None Detected
Yellow
Layer 3 F196522 Tan,Gray Drywall None Detected
103 B1 F196523A Variously Carpet None Detected
F196523B White Carpet Mastic None Detected
103 B2 F196524A Variously Carpet None Detected
F196524B White Carpet Mastic None Detected
Page 1 of 1
e e m e n - 189 county rd 135 glen wood springs,co 81601 9 ^_; 31 3g
www.eLementconsuLts.com
Project#-Ford 010720 Monarch ENVIRONMENTAL INC LEAD ASBESTOS HAZMAT 0
6§f"�I
`�/2020
ASPEN
BUILDING DEPARTMENT
6
tiff° eurofins • ASBESTOS BULK ANALYSIS
By: POLARIZING LIGHT MICROSCOPY
CEI
Client: Element Environmental LLC Lab Code: 6A200030
189 CR 135 Date Received: 01-08-20
Glenwood Springs, CO 81601 Date Analyzed: 01-10-20
Date Reported: 01-10-20
Project: Ford 010720 Monarch, 2155 Monarch
ASBESTOS BULK PLM, EPA 600 METHOD
Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS
Lab ID Description Attributes Fibrous Non-Fibrous
103 Al Skip Trowel Texture Heterogeneous 25% Fiberglass 42% Binder None Detected
Layer 1 Gray,White 3% Talc 25% Calc Carb
F196520 Fibrous 5% Paint
Bound
Layer 2 Joint Compound Homogeneous 3% Talc 62% Binder None Detected
F196520 Off-white 35% Calc Carb
Non-fibrous
Bound
Layer 3 Drywall Heterogeneous 15% Cellulose 80% Gravel None Detected
F196520 Tan,Gray 5% Fiberglass
Fibrous
Bound
103 A2 Skip Trowel Texture Heterogeneous 25% Fiberglass 42% Binder None Detected
Layer 1 Gray,White 3% Talc 25% Calc Carb
F196521 Fibrous 5% Paint
Bound
Layer 2 Joint Compound Homogeneous 3% Talc 62% Binder None Detected
F196521 Off-white 35% Calc Carb
Non-fibrous
Bound
Layer 3 Drywall Heterogeneous 15% Cellulose 80% Gravel None Detected
F196521 Tan,Gray 5% Fiberglass
Fibrous
Bound
103 A3 Skip Trowel Texture Heterogeneous 15% Fiberglass 45% Binder None Detected
Layer 1 Gray,White 10% Talc 25% Calc Carb
F196522 Fibrous 5% Paint
Bound
Page 1 of 3
"
e e m en t 189 county rd 135 gtenwood springs,co 816oi g ^2; �3139 � l v E;
www.etementconsutts.com
Project#-Ford 010720 Monarch ENVIRONMENTAL INC LEAD ASBESTOS HAZMAT 6§f"�I O //2020
ASPEN
BUILDING DEPARTMENT
7
tiff° eurofins • ASBESTOS BULK ANALYSIS
By: POLARIZING LIGHT MICROSCOPY
CEI
Client: Element Environmental LLC Lab Code: 6A200030
189 CR 135 Date Received: 01-08-20
Glenwood Springs, CO 81601 Date Analyzed: 01-10-20
Date Reported: 01-10-20
Project: Ford 010720 Monarch, 2155 Monarch
ASBESTOS BULK PLM, EPA 600 METHOD
Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS
Lab ID Description Attributes Fibrous Non-Fibrous
Layer 2 Joint Compound Homogeneous 10% Talc 50% Binder None Detected
F196522 Off-white,Yellow 35% Calc Carb
Non-fibrous 5% Paint
Bound
Layer 3 Drywall Heterogeneous 15% Cellulose 80% Gravel None Detected
F196522 Tan,Gray 5% Fiberglass
Fibrous
Bound
103 B1 Carpet Heterogeneous 80% Synthetic Fiber 20% Binder None Detected
F196523A Variously
Fibrous
Bound
F196523B Carpet Mastic Heterogeneous 100% Mastic None Detected
White
Non-fibrous
Bound
103 B2 Carpet Heterogeneous 80% Synthetic Fiber 20% Binder None Detected
F196524A Variously
Fibrous
Bound
F196524B Carpet Mastic Heterogeneous 100% Mastic None Detected
White
Non-fibrous
Bound
Page 2 of 3
e e m en t 189 county rd 135 genwood springs,co 81601 9 ^ 31 39 (,
www.erementconsults.com !
Project#-Ford 010720 Monarch ENVIRONMENTAL INC LEAD ASBESTOS HAZMAT 6§f"�I O //2020
ASPEN
BUILDING DEPARTMENT
8
eurofins
CEI
LEGEND: Non-Anth = Non-Asbestiform Anthophyllite
Non-Trem = Non-Asbestiform Tremolite
Calc Carb =Calcium Carbonate
METHOD: EPA 600/R93/116 and EPA 600/M4-82/020
REPORTING LIMIT: <1%by visual estimation
REPORTING LIMIT FOR POINT COUNTS: 0.25%by 400 Points or 0.1%by 1,000 Points
REGULATORY LIMIT: >1%by weight
Due to the limitations of the EPA 600 method, nonfriable organically bound materials(NOBs)such as
vinyl floor tiles can be difficult to analyze via polarized light microscopy(PLM). EPA recommends that
all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission
Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is
not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on
request.
This report relates only to the samples tested or analyzed and may not be reproduced, except in full,
without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding
the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Samples were received in
acceptable condition unless otherwise noted. This report may not be used by the client to claim
product endorsement by NVLAP or any other agency of the U.S. Government.
Information provided by customer includes customer sample ID and sample description.
ANALYST: APPROVED BY: lG:w,/. Gl/�---
Dana Roach Tianbao Bai,Ph.D.,CIH
Laboratory Director
Kyle Demsko
NVIAAP
TESTING
NVLAP LAB CODE 6002SS-0
Page 3 of 3
189 countyrd 135 gtenwood springs,co 816oi g ^ ';]39 ;t`' t '} '
e e rn e n t � �,,161 �ij
www.etementconsutts.com
Project#-Ford 010720 Monarch ENVIRONMENTAL INC LEAD ASBESTOS HAZMAT 0
6§f"�I
`�/2020
ASPEN
BUILDING DEPARTMENT
9
10.0- CERTIFICATES
..
A i
Colorado Department ` Colorado Department
alPubhcHealth of Public Health it
and Environment and Environment
ASBESTOS ASBESTOS
CERTIFICATION* CERTIFICATION*
This certifies that This certifies that
Joshua Jay Johnson s' Ellen Johnson
Certification No.:18401 Certification No,:23799
has met the requirements of25-7-507,C.R.S.and Air Quality Control Ft- has met the requirements of 25-7-507,C.R.S.and Air Quality Control -
Commission Regulation No.9.Pan B.and is hereby certified by the ,.._- Commission Regulation No.8,Part B,and is hereby certified by the
state of Colorado in the following discipline: state of Colorado in the following discipline:
34
Building Inspector* Building Inspector*
Issued: July 31,2019 `: Issued: July 17,2019
Expires: August 01,2020 Expires: July 19.2020
i c. .:,• mn•���
. • L riJ- -.g a�r;�,,r<•n.e��,. e„;n u;;. `Zm ��w-—
.4.1.0 Ramon.,.
SEAL ,,WA '1.'' ef,Wd Ji°�LIC162,,likn4.41a.,�.Pga 4i E,'`I`Ab n
..�' <ii '+n i y Y t,}p tit �a aI 3 r.6
r •r 26
Colorado Department
of Public Health
and Emiroruncnt
ASBESTOS CONSULTING FIRM
This certifies that
Element Environmental LLC ,
•
Registration No.:ACF-21640
has met the registration requirements of 25-7-507.C.R.S.and the Air Quality Control
Commission Regulation No.8,Part B.and is hereby authorized to perform asbestos consulting
activities as required under Regulation No 8,Part B,in the state of Colorado.
Issued: January 25.2019 -
Expires: January 25,2020 ( 1ict..,
aanonmearw nes�ass�wrs.-... i
/eat-%r
e N e m e n t 18g county rd 135 glenwood springs,co 81601 g ^ '31 3g ivED
www.elementconsults.com
Project#-Ford 010720 Monarch ENVIRONMENTAL INC LEAD ASBESTOS HAZMAT 0
6�f2//2020
ASPEN
BUILDING DEPARTMENT