HomeMy WebLinkAboutMaster Permit.215 S Monarch St.0041-2020-BCOM (5) e e rn e n t ENVIRONMENTAL INC 189 County Rd. 135 Glenwood Springs, CO 81601 josh@elementconsults.com (970) 274-3139 Property Address Asbestos Sampling Report 215 S. Monarch St. #103 Date: 01/11/2020 Aspen, CO 81611 Date of Inspection: 01/07/2020 o Client: Element Environmental Project#: t) Ford 010720 Monarch John Ford cu Attn: Client Job Name John Ford Monarch Office TABLE OF CONTENTS Building Inspector: 1.0 - Scope of Work 2.0 - Sampling Requirements Ellen Johnson 3.0 - Sampling Methodology 4.0 - Laboratory CDPHE#23799 5.0 -Suspect Materials Sampled 6.0 -Table of Results 7.0 - Description of Sampling Area Joshua Johnson 8.0 -Conclusion 9.0 - Lab Report CDPHE#18401 10.0 -Certificates Asbestos Samples Analyzed: 5 Positive Asbestos Samples: 0 I1KE IVE D 08/17/2020 ASPEN BUILDING DEPARTMENT 2 1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel. Element Environmental conducted a visible inspection for visible materials that would be impacted during the remodel. This inspection was limited to the areas found in the Description of the Sampling Area 7.0. Although sampling is destructive in nature, this was a non-invasive inspection. It was of materials that were accessible. If other suspect materials become visible/apparent during demolition or construction activities, work in that area should be halted and more sampling/testing must take place, per Colorado regulations. Any suspect materials that were not tested are to be assumed to contain asbestos. 2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with Colorado State Requirements. The minimum number of samples per homogenous areas are as follows: 2.1-Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples 1,000 sq.ft.-5,000sq.ft.- Minimum of 5 samples >5,000 sq.ft. Minimum of 7 samples 2.2-Miscellaneous materials- Minimum of 2 samples 2.3-Thermal Systems Insulation(TSI)- Minimum of 3 samples 3.0- The purpose of the inspection is to identify materials that are homogenous. A homogeneous area is defined as one which shares suspect material, texture, color, location, and/or apparent time of construction. The materials are segregated into separate homogenous areas. The size is determined and then samples are taken. The materials are touched to determine friability. Friable ACM is material that can be crushed or reduced to powder by hand pressure. The samples are taken in a random numerical sequence. 4.0- Ellen Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 23799, performed the inspection. The findings were reviewed by Josh Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 18401. Samples taken were sent to CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be trace, or<1% asbestos, is considered to be ACM material. This material would still be a regulated material by CDPHE. The sample must have an additional "point count" performed to be considered less than 1% and not be regulated by the CDPHE. The lab's documents with analyses and findings are found below. RECEIVED i89 count rd 135 glenwood springs,co 816o1 970.274 3,39 /2 0 2 0 e e rn e n t y www.etementconsults.com Project#-Ford 010720 Monarch ENVIRONMENTAL!NC LEAD ASBESTOS HAZMAT A1 EN Pl��O PARTMENT 3 5.0- SUSPECT MATERIALS SAMPLES • Drywall • Joint Compound • Texture • Carpet and Mastic • Tape 6.0- TABLE OF RESULTS HOMOGENOUS DESCRIPTION OF AREA ACM CATEGORY NUMBER APPROXIMATE ACM ASSESSMENT CATEGORIES %AND TYPE OF AREA OF SQ.FT.* ASBESTOS FOUND SAMPLES (A) Skip Trowel Texture Surfacing 3 250 sq.ft. Friable Non-ACM No Asbestos Detected (B) Carpet and Mastic Miscellaneous 2 "250 sq.ft. Non-Friable Non-ACM No Asbestos Detected Key: ACM Assessment Categories: 1-Damaged or significantly damaged Thermal Systems Insulation 6-ACM with potential for significant damage (TSI)ACM 7-Friable ACM with low potential for damage 2-Damaged friable surfacing ACM Other-ACM not classified in the above Assessment Categories 3-Significantly damaged friable Surfacing ACM N/A-Not Applicable 4-Damaged or significantly damaged friable Miscellaneous ACM 5-ACM with potential for damage *Square footage is estimated and not for bidding purposes 7.0- DESCRIPTION OF SAMPLING AREA • The Skip Trowel Texture in the Office • The Carpet and Mastic in the Office 8.0- CONCLUSION No asbestos was detected in any of the samples taken. Sincerely, Ellen Johnson RECEIVED i89 count rd t35 glenwood springs,co 816o1 970.274.3139 /2 0 2 0 e e rn e n t y www.etementconsults.com EN Project#-Ford 010720 Monarch ENVIRONMENTAL!NC LEAD ASBESTOS HAZMAT PARTMENT BUHREU � PA 4 9.0- LAB REPORT tiff eurofins CEI ASBESTOS ANALYTICAL REPORT By: Polarized Light Microscopy Prepared for Element Environmental LLC CLIENT PROJECT: Ford 010720 Monarch, 2155 Monarch LAB CODE: 6A200030 TEST METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 REPORT DATE: 01/10/20 TOTAL SAMPLES ANALYZED: 5 #SAMPLES>1%ASBESTOS: TOTAL LAYERS ANALYZED: 13 e e m e n t 189 county rd 135 glenwood springs,co 81601 g ^ '31 39 IVE www.elementconsults.com Project#-Ford 010720 Monarch ENVIRONMENTAL INC LEAD ASBESTOS HAZMAT B 6§f"�I `�/2020 ASPEN BUILDING DEPARTMENT 5 eurofins Asbestos Report Summary .• By: POLARIZING LIGHT MICROSCOPY CEI PROJECT: Ford 010720 Monarch, 2155 Monarch LAB CODE: 6A200030 METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 IASBESTOS Client ID Layer Lab ID Color Sample Description 103 Al Layer 1 F196520 Gray.White Skip Trowel Texture None Detected Layer 2 F196520 Off-white Joint Compound None Detected Layer 3 F196520 Tan,Gray Drywall None Detected 103 A2 Layer 1 F196521 Gray,White Skip Trowel Texture None Detected Layer 2 F196521 Off-white Joint Compound None Detected Layer 3 F196521 Tan,Gray Drywall None Detected 103 A3 Layer 1 F196522 Gray,White Skip Trowel Texture None Detected Layer 2 F196522 Off-white, Joint Compound None Detected Yellow Layer 3 F196522 Tan,Gray Drywall None Detected 103 B1 F196523A Variously Carpet None Detected F196523B White Carpet Mastic None Detected 103 B2 F196524A Variously Carpet None Detected F196524B White Carpet Mastic None Detected Page 1 of 1 e e m e n - 189 county rd 135 glen wood springs,co 81601 9 ^_; 31 3g www.eLementconsuLts.com Project#-Ford 010720 Monarch ENVIRONMENTAL INC LEAD ASBESTOS HAZMAT 0 6§f"�I `�/2020 ASPEN BUILDING DEPARTMENT 6 tiff° eurofins • ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY CEI Client: Element Environmental LLC Lab Code: 6A200030 189 CR 135 Date Received: 01-08-20 Glenwood Springs, CO 81601 Date Analyzed: 01-10-20 Date Reported: 01-10-20 Project: Ford 010720 Monarch, 2155 Monarch ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non-Fibrous 103 Al Skip Trowel Texture Heterogeneous 25% Fiberglass 42% Binder None Detected Layer 1 Gray,White 3% Talc 25% Calc Carb F196520 Fibrous 5% Paint Bound Layer 2 Joint Compound Homogeneous 3% Talc 62% Binder None Detected F196520 Off-white 35% Calc Carb Non-fibrous Bound Layer 3 Drywall Heterogeneous 15% Cellulose 80% Gravel None Detected F196520 Tan,Gray 5% Fiberglass Fibrous Bound 103 A2 Skip Trowel Texture Heterogeneous 25% Fiberglass 42% Binder None Detected Layer 1 Gray,White 3% Talc 25% Calc Carb F196521 Fibrous 5% Paint Bound Layer 2 Joint Compound Homogeneous 3% Talc 62% Binder None Detected F196521 Off-white 35% Calc Carb Non-fibrous Bound Layer 3 Drywall Heterogeneous 15% Cellulose 80% Gravel None Detected F196521 Tan,Gray 5% Fiberglass Fibrous Bound 103 A3 Skip Trowel Texture Heterogeneous 15% Fiberglass 45% Binder None Detected Layer 1 Gray,White 10% Talc 25% Calc Carb F196522 Fibrous 5% Paint Bound Page 1 of 3 " e e m en t 189 county rd 135 gtenwood springs,co 816oi g ^2; �3139 � l v E; www.etementconsutts.com Project#-Ford 010720 Monarch ENVIRONMENTAL INC LEAD ASBESTOS HAZMAT 6§f"�I O //2020 ASPEN BUILDING DEPARTMENT 7 tiff° eurofins • ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY CEI Client: Element Environmental LLC Lab Code: 6A200030 189 CR 135 Date Received: 01-08-20 Glenwood Springs, CO 81601 Date Analyzed: 01-10-20 Date Reported: 01-10-20 Project: Ford 010720 Monarch, 2155 Monarch ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non-Fibrous Layer 2 Joint Compound Homogeneous 10% Talc 50% Binder None Detected F196522 Off-white,Yellow 35% Calc Carb Non-fibrous 5% Paint Bound Layer 3 Drywall Heterogeneous 15% Cellulose 80% Gravel None Detected F196522 Tan,Gray 5% Fiberglass Fibrous Bound 103 B1 Carpet Heterogeneous 80% Synthetic Fiber 20% Binder None Detected F196523A Variously Fibrous Bound F196523B Carpet Mastic Heterogeneous 100% Mastic None Detected White Non-fibrous Bound 103 B2 Carpet Heterogeneous 80% Synthetic Fiber 20% Binder None Detected F196524A Variously Fibrous Bound F196524B Carpet Mastic Heterogeneous 100% Mastic None Detected White Non-fibrous Bound Page 2 of 3 e e m en t 189 county rd 135 genwood springs,co 81601 9 ^ 31 39 (, www.erementconsults.com ! Project#-Ford 010720 Monarch ENVIRONMENTAL INC LEAD ASBESTOS HAZMAT 6§f"�I O //2020 ASPEN BUILDING DEPARTMENT 8 eurofins CEI LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb =Calcium Carbonate METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 REPORTING LIMIT: <1%by visual estimation REPORTING LIMIT FOR POINT COUNTS: 0.25%by 400 Points or 0.1%by 1,000 Points REGULATORY LIMIT: >1%by weight Due to the limitations of the EPA 600 method, nonfriable organically bound materials(NOBs)such as vinyl floor tiles can be difficult to analyze via polarized light microscopy(PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request. This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government. Information provided by customer includes customer sample ID and sample description. ANALYST: APPROVED BY: lG:w,/. Gl/�--- Dana Roach Tianbao Bai,Ph.D.,CIH Laboratory Director Kyle Demsko NVIAAP TESTING NVLAP LAB CODE 6002SS-0 Page 3 of 3 189 countyrd 135 gtenwood springs,co 816oi g ^ ';]39 ;t`' t '} ' e e rn e n t � �,,161 �ij www.etementconsutts.com Project#-Ford 010720 Monarch ENVIRONMENTAL INC LEAD ASBESTOS HAZMAT 0 6§f"�I `�/2020 ASPEN BUILDING DEPARTMENT 9 10.0- CERTIFICATES .. A i Colorado Department ` Colorado Department alPubhcHealth of Public Health it and Environment and Environment ASBESTOS ASBESTOS CERTIFICATION* CERTIFICATION* This certifies that This certifies that Joshua Jay Johnson s' Ellen Johnson Certification No.:18401 Certification No,:23799 has met the requirements of25-7-507,C.R.S.and Air Quality Control Ft- has met the requirements of 25-7-507,C.R.S.and Air Quality Control - Commission Regulation No.9.Pan B.and is hereby certified by the ,.._- Commission Regulation No.8,Part B,and is hereby certified by the state of Colorado in the following discipline: state of Colorado in the following discipline: 34 Building Inspector* Building Inspector* Issued: July 31,2019 `: Issued: July 17,2019 Expires: August 01,2020 Expires: July 19.2020 i c. .:,• mn•��� . • L riJ- -.g a�r;�,,r<•n.e��,. e„;n u;;. `Zm ��w-— .4.1.0 Ramon.,. SEAL ,,WA '1.'' ef,Wd Ji°�LIC162,,likn4.41a.,�.Pga 4i E,'`I`Ab n ..�' <ii '+n i y Y t,}p tit �a aI 3 r.6 r •r 26 Colorado Department of Public Health and Emiroruncnt ASBESTOS CONSULTING FIRM This certifies that Element Environmental LLC , • Registration No.:ACF-21640 has met the registration requirements of 25-7-507.C.R.S.and the Air Quality Control Commission Regulation No.8,Part B.and is hereby authorized to perform asbestos consulting activities as required under Regulation No 8,Part B,in the state of Colorado. Issued: January 25.2019 - Expires: January 25,2020 ( 1ict.., aanonmearw nes�ass�wrs.-... i /eat-%r e N e m e n t 18g county rd 135 glenwood springs,co 81601 g ^ '31 3g ivED www.elementconsults.com Project#-Ford 010720 Monarch ENVIRONMENTAL INC LEAD ASBESTOS HAZMAT 0 6�f2//2020 ASPEN BUILDING DEPARTMENT