Loading...
HomeMy WebLinkAboutFile Documents.501 Dean St.0019-2022-BCOM (13) ENTRY AUTOMATED BI-PART DOORS: L1 A (& L1 B) Marc Winkler From: Jordan, Gilbert <Gilbert.Jordan@sbdinc.com> Sent: Wednesday, March 02, 2022 15:14 To: Marc Winkler Subject: RE: Residences at The Little Nell Stanley Doors Marc, The U-factor for Dura-Glide 2000 All Glass • Package width: 119.5 inches • Package Height: 103.75 inches • Glass: % inch clear tempered. • U-factor: 1.04 • SHGC: 0.52 • VT: 0.58 If you need anything else, please contact me. Regards, Gilbert Jordan, CSI, RA Architectural Specification Consultant STANLEY Access Technologies M (817) 271-9137 Gilbert.Jordan@sbdinc.com I www.STANLEYAccess.com STANLEY. Q Years of Access Technologies ✓O INNOVATION A video about our Touchless entrance options: Hands-Free Solutions. Information about our ProCare ICU/CCU product line: our ProCare Series, Link to our COVID-19 informational page on our site:COVID-19 Resource Page ©Stanley Access Technologies, LLC From: Marc Winkler<mwinkler@billposs.com> Sent: Wednesday, March 2, 2022 1:53 PM To:Jordan, Gilbert<gilbert.jordan@sbdinc.com> Subject: RE: Residences at The Little Nell Stanley Doors !! CAUTION, EXTERNAL MESSAGE !! RECEIVED 1 03/14/2022 ASPEN BUILDING DEPARTMENT FENESTRATION PRODUCT RATING OVERALL RATING CERTIFICATE IP U-Factor: (Btu/h•ft2•°F) KAWNEER STOREFRONT SYSTEM, SHGC: WINDOWS: B 001, B 002, B 003, & B 004 VT: DOORS: L2 A & L2 B Company: Signature: Date: STIPULATES THAT THE MATERIALS LISTED ON THIS CERTIFICATE WERE INSTALLED ON THE PROJECT IDENTIFIED BELOW. PROJECT INFORMATION: Street Address: City: State: Zip: GLAZING CONTRACTOR/INSTALLER: Contact Person: Street Address: Phone Number: City: State: Zip: GLAZING MATERIAL SUPPLIER: Contact Person: Street Address: Phone Number: City: State: Zip: Glass and Spacer Type: Center-of-glass(C.O.G.)U-factor: Center-of-glass(C.O.G.)SHGC: Center-of-glass(C.O.G.)VT Btu/h•ft2•°F FRAMING MATERIAL SUPPLIER: Contact Person: Street Address: Phone Number: City: State: Zip: U-factor Matrix SHGC Matrix VT Matrix (BtU/h•ft2i°F) Product Line: ? C.O.G. Overall C.O.G. Overall COG Overall 1620UT CURTAIN WALL SYSTEM (WARM U-factor U-factor SHGC SHGC VT VT re 0.48 0.51 0.75 0.69 0.75 0.69 EDGE SPACER)WITH FIBERGLASS I 0.46 0.49 0.70 0.65 0.70 0.64 PRESSURE PLATE 0, la 0.44 0.47 0.65 0.60 0.65 0.59 _ The overall ratings for U-factor and SHGC are based on a a 0.42 0.45 0.60 0.55 0.60 0.55 size of 2000 mm x 2000 mm(78.75 in x 78.75 in)as 1- 0.40 0.43 0.55 0.51 0.55 0.50 required in NFRC 100 and NFRC 200. 0.38 0.42 0.50 0.46 0.50 0.46 _ Overall U-factors,Solar Heat Gain Coefficients(SHGC)and 0.36 0.40 0.45 0.42 0.45 0.41 Visible Transmittances(VT)listed in the matrix were 0.34 0.38 0.40 0.37 0.40 0.37 determined in accordance with NFRC 100 and NFRC 200 0.32 0.36 0.35 0.33 0.35 0.32 respectively by an NFRC accredited independent laboratory. 0.30 0.35 0.30 0.28 0.30 0.27 ACCREDITED INDEPENDENT LABORATORY: 0.28 0.33 0.25 0.23 0.25 0.23 Intertek Building & Construction 0.26 0.31 0.20 0.19 0.20 0.18 0.24 0.29 , 0.15 0.14 0.15 0.14 ( Reference Simulation Report# J7572.05-116-45 0.22 0.28 0.10 0.10 0.10 0.09 0.20 0.26 0.05 0.05 0.05 0.05 Directions: Fill out form completely. Determine the Overall Rating 0.18 0.24 Air Leakage less than or equal to<_0.06 cfm/ft2 for this project by using the C.O.G U-Factor(winter-time),C.O.G. 0.16 0.22 at a test pressure of 1.57 psf when tested in SHGC,COG VT from Table 1 and looking up the overall rating accordance with(check one): 0.14 0.20 AAMA/WDMA/CSA 101/I.S.2/A440 from Linear the Overall Rating in the space`above II j1v i� t- ,�a .r, 0.12 0.19 X ASTM E283 interpolationpermitted. 0.10 0.17 NFRC 400 03/14/2022 OCTOBER,2019 COCD211C EC 955AtrEIy BUILDING DEPARTMENT