HomeMy WebLinkAboutFile Documents.950 Cemetery Ln.0152.2019 (27).ARBK HealthSafe
e
I NSPECTIONS
HealthSafe Inspections Inc
390 Apple Drive
Basalt CO 81621
970-920-2100
Jim Baker
CDPHE Asbestos Building Inspector,Asbestos Air Monitoring Specialist (AMS) &
Project Designer Certification #13437
CDPHE Lead-Based Paint Inspector & Lead Hazard Assessor Certification #23607
ASBESTOS REPORT
DATE
03/15/2018
CLIENT
Costanza
c/o Kim Raymond Architects, Inc.
300 E Hyman, Suite A
Aspen CO 81611 C
PROJECT PROPERTY ADDRESS REEIuED
12/10/18
950-1 Cemetery Lane,Aspen, Colorado 81611
ASPEN
For orientation purposes, the front door faces south. BUILDING DEPARTMENT
A
4 e
1
COLORADO & FEDERAL ASBESTOS REGULATIONS SUMMARY
Regulation No. 8 Part B—Asbestos of the Colorado Department of Public Health and
Environment(CDPHE),Air Quality Control Commission requires a State-certified
Asbestos Building Inspector to inspect and collect bulk samples of all suspect asbestos
containing materials (ACM) or suspect asbestos containing building materials (ACBM)
prior to their disturbance, removal or demolition and disposal. The suspect materials shall
be analyzed by a NVLAP accredited laboratory by polarized light microscopy(PLM)
using EPA 600 analytical method.A material which is estimated to contain more than 1%
asbestos is classified as ACM/ACBM and regulated by the State and Federal
governments.Any friable (able to crush or reduce to powder by finger pressure) asbestos
with trace amounts of asbestos fibers or less than 1%must be point-counted using EPA
400 analytical method to prove that it is indeed less than 1%; if not, it must be classified
as ACM/ACBM and shall be treated as a State and Federal regulated material.Any
friable asbestos containing material (greater than 1% asbestos concentration) or
ACM/ACBM that could be rendered friable during its removal or demolition and disposal
shall require an asbestos abatement by a certified asbestos abatement contractor to
remove and dispose of the material(s).
A Colorado State (CDPHE)issued asbestos abatement permit is required for the
following trigger levels of ACM/ACBM:
1. Residential buildings of four or fewer units--if more than 32 square feet of any
surface coverage (e.g., gypsum wallboard or drywall and associated applied surfacing
materials/textures, acoustic sprays,joint compounds,plaster, etc.), 50 feet of asbestos
covered or asbestos insulated pipe or any material which would fill a 55-gallon drum is
going to be disturbed, removed or disposed of, an asbestos abatement permit is required.
2. Residential complexes with more than four residential units, public access areas to a
residential building, commercial and retail buildings,public and civic buildings,
industrial buildings--if more than 160 square feet of surfacing materials,, '
vro
or more than 35 cubic feet(NESHAP) or 55-gallon drum(CDPHE) of susp L�
ACM/ACBM is going to be disturbed, removed or disposed of, an asbestoj 5b?tpt r1t8
permit is required under NESHAP and by the CDPHE. See note below on cY A.
ASPEN
The regulations require an absolute minimum of 3 samples (EPA sugg801E1 01G9EPARTMENT
homogenous suspect surfacing and TSI materials and an absolute minimum of 2 samples
of homogenous miscellaneous materials or any number of"samples sufficient to
determine whether a material is ACM" (Reg8.IV.D.3). More samples are required based
on surface area or volume. These are minimums; the asbestos building inspector has the
field responsibility to determine homogenous materials and the number of samples to
collect per material; more than the minimum number of samples may be necessary at the
discretion of the inspector.An assessment of friability and functional space conditions of
the materials are also the inspector's field responsibilities.
2
OSHA compliance is required for all employers and employees no matter the
quantity of asbestos present with strict regulations regarding 10 sf or more of TSI or
friable surfacing materials, and therefore it does not matter what the quantity or
State trigger levels are: all suspect ACM/ACBM shall be inspected and tested for
asbestos prior to their disturbance, removal and disposal for worker protection and
safety. See EPA 40 CFR 763.121 Worker Protection Rule, OSHA 29 CFR 1910.134
Respirator Protection Standard, OSHA 29 CFR 1910.1001 General Industry Standard and
OSHA 29 CFR 1926.1101 Construction Standard regulations when dealing with asbestos
hazards.
Note: County or City regulations may be more stringent.
CLIENT BACKGROUND
The owner of the property hired Kim Raymond Architects, Inc. to make a design and
plans for an interior remodel-renovation of the kitchen and bathrooms as well as a
demolition and change the angle of the west living-dining room wall from its current
angle inward to an outward angle. The basement section has been mostly renovated
during an earlier remodel, so the focus is on the main floor level. This inspection included
exterior north, east and west walls related to the west wall demolition and changes as well
as the main floor interior spaces, primarily focusing on the planned bathrooms and
kitchen remodel.
VISUAL INSPECTION & LABORATORY FINDINGS
An inspection was conducted by Jim Baker of HealthSafe on March 6, 2018. Suspect
ACM/ACBM were identified and sampled on the main floor level and west wall impacts.
Those materials are the following: RECEIVED
1. Main Floor Gypsum Wallboard/Drywall System: a homogeneous t p�cJ,ji )gibt
compounded drywall system (classified as a miscellaneous material'as'a cofnrilete
integral system) [samples 1-2: F-W-J-1,2]; these original composite livgAtaped
and joint compounded drywall materials are on bathroom and stgetodgicamtEINT
walls of the main entry, stairwell and main floor area of the house with a flat-
finish surfacing material/texture. The estimated surface area of impact is more
than 1,000 sf, but less than 5,000 sf, requiring a minimum of at least two
composite core samples of all drywall layers ("...number of samples sufficient to
determine" ...if asbestos is present or not). The PLM analytical estimated results:
NONE DETECTED.
2. Flat Finish Surfacing Material/Texture: a homogeneous flat trowel-applied
surfacing material/texture [samples 3-7: F-W-T-1,2,3,4,5]. This surfacing
material/texture is on bathroom and closet ceilings and walls of the main entry,
stairwell and main floor areas. The estimated surface area of impact is more than
3
1,000 sf, but less than 5,000 sf, requiring a minimum of at least five
surfacing/texture material samples. The PLM analytical estimated results: NONE
DETECTED.
3. Exterior tar paper underneath the cedar shingles: a homogeneous miscellaneous
material requiring at least one sample [sample 8: X-TP]. The estimated surface
impact is approximately 500 sf. The PLM analytical estimated results: NONE
DETECTED.
There were no other additional suspect asbestos building materials to sample which were
slated to be disturbed, removed or disposed of in the remodel-renovation of the main
floor areas and west exterior wall assembly mentioned above.A total of 8 suspect
homogeneous ACM/ACBM bulk samples were collected and [8 samples were analyzed.
The bulk samples were analyzed by PLM by a NVLAP accredited laboratory in
accordance with Colorado State Regulation 8 for the presence of asbestos mineral fibers.
There is NO asbestos in all 8 samples analyzed. The interior samples were collected
randomly in significantly separated areas of the living room, dining room, kitchen, master
bedroom and master bathroom.
See supporting Hayes Microbial Consulting, Inc. data report#18007388.
HEALTHSAFE CONCLUSIONS
There is NO asbestos in any of the suspect building materials slated to be impacted by the
remodel-renovation and west wall demolition. NO asbestos abatement will be required.
All building materials needing to be removed or disturbed can be dealt with without the
concerns for asbestos fibers. All building waste and debris can be disposed of in any
landfill which accepts normal, non-hazardous building waste.
Sincerely Submitted,
Jim Baker RECEIVED
12/10/18
ASPEN
BUILDING DEPARTMENT
4
HMC #18007388
HAYES
MICROBIAL CONSULTING
3005 East Boundary Terrace,#F
Midlothian,VA 23112, USA
804.562.3435 Fax: 804.447.5562
contact@hayesmicrobial.com
http://hayesmicrobial.com/
Analysis Report prepared for
HealthSafe Inspections
390 Apple Drive
Basalt, CO. 81621
Phone: 970-920-2100
Job Name: Costanza
950-1 Cemetery Ln RECEIVED
Aspen CO 81611 �/
Date Sampled: 03-06-2018 12/10/18
Date Analyzed: 03-15-2018
Report Date: 03-15-2018 ASPEN
BUILDING DEPARTMENT
EPA Laboratory ID#VA01419
O4eHeaItervices
Connecticut Department
of Public Health
NVLAP Lab Code: 500096-0 Asbestos License: 300435 License:#PH-0198
Page 1 of 4
4111D HAYES
MICROBIAL CONSULTING
3005 East Boundary Terrace,#F
Midlothian,VA 23112, USA HMC #18007388
804.562.3435 Fax:804.447.5562
HealthSafe Inspections
390 Apple Drive
Basalt, CO 81621
March 15, 2018
Client Job Number:
Client Job Name: Costanza
950-1 Cemetery Ln
Aspen CO 81611
Dear HealthSafe Inspections,
We would like to thank you for trusting Hayes Microbial for your analytical needs. On March 8, 2018 we received 8 samples by FedEx for the job
referenced above. 8 samples were received in good condition.
The results in this analysis pertain only to this job, collected on the stated date and should not be used in the interpretationfil rChI ob. FtEeport
may not be duplicated, except in full, without the written consent of Hayes Microbial Consulting, LLC. 12/1 O/18
This laboratory bears no responsibility for sample collection activities, analytical method limitations, or your use of the test results. Interpretation and
use of test results are your responsibility. Any reference to health effects or interpretation of mold levels is strictly the opinion oF'k byes Microbial
Consulting. In no event, shall Hayes Microbial Consulting or any of its employees be liable for lost profits or any special, intid16616]E6 @bh' a uential
damages arising out of your use of the test results.
411141 *64---"'
Steve Hayes, BSMT(ASCP)
Laboratory Director
Hayes Microbial Consulting, LLC
Page 2 of 4
QHA Y E S HealthSafe Inspections EPA 600/R-93, M-4/82-020 (PLM)
MICROBIAL CONSULTING 390 Apple Drive
3005 East Boundary Terrace,#F Basalt, CO 81621
Midlothian,VA 23112, USA Phone: 970-920-2100 HMC #18007388
804.562.3435 Fax:804.447.5562
Job Number: Job Name: Costanza Date Collected: 03/06/2018
Collected by: Jim Baker 950-1 Cemetery Ln Date Received: 03/08/2018
Email: healthsafeinspections@gmail.com Aspen CO 81611 Date Reported: 03/15/2018
# Sample Name Description Asbestos Fibers Other Fibers Non-Fibers
1 1 F-W-J-1 Joint Compound/White (None Detected) (None Detected) 100 %
2 2 F-W-J-2 Brittle/White (None Detected) (None Detected) 100 %
3 3 F-W-T-1 Texture/White (None Detected) (None Detected) 100
4 4 F-W-T-2 Texture/White (None Detected) (None Detected) 100 %
5 5 F-W-T-3 Texture/White (None Detected) (None Detected 100
ri
6 6 F-W-T-4 Texture/White (None Detected) (Nin2 ytttn 8 100 %
7 7 F W T 5 Texture/White (None Detected) BU ICIEW A PE §c01/44ENT 100 %
80% Cellulose fibers
8 8 X-TP Fibrous/Brown (None Detected) 20%
Signature: p____9?i5—_, Date: 03/15/2018 Reviewed by: Date: 03/15/2018
Page 3 of 4
4111DHA Y E S HealthSafe Inspections Asbestos - Additional Information
MICROBIAL CONSULTING 390 Apple Drive
3005 East Boundary Terrace,#F Basalt, CO 81621
Midlothian,VA 23112, USA Phone: 970-920-2100 HMC #18007388
804.562.3435 Fax:804.447.5562
All samples were received in acceptable condition unless otherwise noted on the report. The Report must not be used by the client to claim product certification, approval, or
endorsement by:Al HA, NIST, NVLAP NY ELAP, or any agency.The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with
estimating percentages by polarized light microscopy. Measurement uncertainty data can be provided when requested. None detected: Below the detected reporting limit of 1% unless
point counting is performed, then the detected, reporting limit is .25%. Per NY ELAP198.6 (NOB) TEM is the only reliable method to declare an NOB material as Non-Asbestos
Containing. Hayes Microbial Consulting reserves the right to dispose of all samples after a period of 60 days in compliance with state and federal guidelines.
RECEIVED
12/10/18
ASPEN
BUILDING DEPARTMENT
Signature: P__12- 15--, Date: 03/15/2018 Reviewed by: W Date: 03/15/2018
Page 4 of 4
o•�Q•i. `+' ••f•��s \S/ .••�.• V.totit;
1.1� �f •� V. f• /{1 • � • I • ♦1 • t ••1.111111rrV..fllf�p �fIf1111.1•r 1 1• V.Vj11�1��•r • 1144r 0145
1•.• �. 44:
•�Q•i• �. •�4i• �� i.i li$�:�/1/1�f���n .a�1`i111�11/Il%1%�� .i���i11/11�1111/1%/� ��h /1/1/11//�/�r �'yi�11/1/11111����� "a jlff/111111/�1i�� 11/11/�11�%� ���//j��/���w��i���1�1/1�11'���)���•���I�II��••.��Jll jl/,.q 11•4; t.:.:rljl111:lel1)a.it.It 1�•Illljll/;1,zt.�\ql1lljlljl/Ij^..atit *1.;•ei %/oo.t\t:��1lif(�;,oiliO4;7 ay /ill//lll/:.4\ ��� 411/�/111j1//417'Al1I�t14:1//�//!/r�,,�>>ll�N��•.��•r� :��!l,�i/x\\�,�,�i�ir�r�,lllii n���.yh�����ll>,!yn��;2� ��1�k//G% \��:2�y�����l�lli/i%^i���2,h�jrl���rllj •r\� ��rl�lllj!�/n��� h�lr�l�llli,!%/nC�`ia,1i����li�d/1,/i,%/^\. �brl;L�•:!r•���y//I�\\��!ti�����r:41,!,</1I� v�.!R��',�,�r�l,r, .//�\�,.,���r',��/r�',Ir4',./lam\\`.,�4��r������,11,!,-�// \'..I,��I���I�Ir�I,/!, ///�\\,..,Iti�l�l�r:'A�!..�N\\ ,hi/��•'r'•b�.`1 l�\\t'��:i'ii�lrir l,�,</N�\`..,,i����• �
••. -�i�in���`\.;y� ./// \�.�,,� ,•,,�/��\�\��..�,:'.!'`•/jlil���\`�,�'i ` ////� ih �'i "/%/�^�i\�s!:�t�%Jr' .//Ii�\ , 4r /�/i�\��i'tit:A,'Lr. /jlj���y����.�.
./i/ i/. >`�\l r. /lr.. �\\\\ � //l ::���1\\:^�t I�/i :�\\\\\�.;'.;' I//;��-!�`\�\ �'//�i%�\`l�\�.;;,�.}• 1//�i` � l.�,};:b //i ' \liN\. II���!`�.�``\,:
`.` 'I� 'I J'kSIVI IIV *13 .1 iilkk 1 Ii J i A. / '' l' Ill J
� � A� • I r. �— u;p1 ' � � `� aJ1, it-) { r m '/e �} �I��.', �i" �.. It- ) I •
.•. =_.�•
• ciV'Cl6t.. N
4.14C-rg•F:•-.---_. ' * 1,42s,*) .r,•• __-7.:::,:z••••7:4•••••41 I
\low,'.....4,...<
• =:` Colorado Department
4%, " . of Public Health --: =___
==',- and Environment
/
' ASBESTOS '
CERTIFICATION* ,_,::---:
T :::::4:o.4:
his This certifies that .ir
�. :_
.:***igirp.4..
• .• � j �`••----
"�• `"" Jim Baker
'_'='''= i Certification No.: 13437 ..il._ - =
'. 1. - ,tip.J
.;\'. has met the requirements of 25-7-507, C.R.S. and Air Quality Control -,;�
•Kam` .
•w4 = ' ' Commission Regulation No. 8 Part B, and is hereby certified by the
, •:.`' , - `�) state of Colorado in the following discipline: `,4
__•
„'�'<`• l
•�==== Building Inspector
�'EIVE " , -
:::..ice ,�
y
„,....
:,,
';.'A 12/10/18 .=
r� www` L
: ASPEN ;,.
:• ' Issued: April 12 2017 BUILDING DEPARTMENT • ':
� : jN::�• ;,;• ;, , Expires: April 22, 2018 ,.
:il_`.�\wwwwww\
.ww.-o_
I c4:-.:zzist.sii44-......
%�� 11 *This certificate is valid only with the possession of a t`,"... _
`0 ' current Division-approved training course certification "
�:,:: -
in the discipline specified above. Aut orized APCD Rep sent tive
• = .
��•�� ` SEAL ''
�••S i �� ram. Y N -Z 'c"'! f r
.//--• )t MAIIRj 1 rt a �.. r/�1r�all IM �)(t 1 ! r� Y I ,�1 J, - d
/./, 1 0 .17YYFr717i7111AIP1C��lYiII�MAIt1RFfIV?7, , Mint l ,�-,} �_ �0 ;`_�r .I i i} ;j 'l ,E1@ a Tl " r \ ww `-to
r ' Y,, t `i r I a ,"
,. el:*".; r+ Via -- . Y •..�
tatiC41;H:.46:** --
\ ;r, A�i%/%j//i *.:::�/0/I.l VN:r�1 r ,. �i '.1i z,. „f }j ,0," �j t 0,. �!; ,- IvYi_���ii♦
••i . 1\V/ ,i 1i \l\V✓.✓ 1 �r. �C e r t .+.i1 s i�t !;f. tr`' :, ` 'Il , f \v � �
, r•••i Ili,,vvi j;,,,rve111,i,,;, y,;;•i ;'r , r,?f , , ,. i.• �,.�,r ♦ r,,' ,'.. ,ti r !`� `mot' ", .
1.iz.Z.TNI�A�f:'`P14,0.��4.141�1�A����i�/''''.r.kw..,00 ',v },r ---. sAI ,I,x ‘s.,''.. '. �.,." * r ••,:/'''�r`;"''''- ..'1 , ''''~-• `..� , ', �;�:�'. ,.
_•,�.M�Ii' `�...4.W./,�i�.�\••'•it,.....• •Ii'.,\ -'0°0•..f.•.•' ,'q.t...1f.1.1l.". ..0♦.1.'.f.1a . '1_LOt11A•. /•. /_111.4.4•,�•�•r. .•i♦1`R...•