Loading...
HomeMy WebLinkAboutFile Documents.950 Cemetery Ln.0152.2019 (41).ARBK Residential Design Standards Administrative Compliance Review Staff Checklist - Single Family and Duplex CITY OF ASPEN Address:950 Cemetery Lane Parcel ID:273512283001 Zone District/PD: R-15 Garrett Digitally signed by Garrett Approved: DN:Latimer Chris Beebe DN:on-Garrett Latimer Representative: plans/elevations attached) La rimer Date:2.018.10.02 10:53:06 Email:bcchris6l @gmaiI.com (Approved 0600 Phone:970-379-4214 Disclaimer:This application is only valid for the attached design.If any element of the design subject to Residential Design Standards changes prior to or during building permit review, the applicant shall be required to apply for a new Administrative Compliance Review. Alternative. Complies Compliant N/A Sheet#(s)/Notes B.1.Articulation of Building Mass r Property is located outside the Aspen I nfill area. (Non-flexible) B.2.Building Orientation ri Not in scope. (Flexible) B.3.Build-to Requirement The minimum front yard setback for this property is 25' so this standard (Flexible) ri does not apply. ri B.4.One Story Element The existing garage meets the requirements for this standard, but is an existing (Flexible) non-conformity as it does not meet the garage placement standard. This element is not altered as part of the scope of work and therefore does not apply. C.1.Garage Access Site does not have access from private street or alley. (Non-flexible) C.2.Garage Placement r Location of existing garage does not comply with the requirements of this standard (Non flexible) but no alterations are proposed to this element, this standard does not apply. C.3.Garage Dimensions T Existing carport is being converted to a garage but the dirrREnEWEr (Flexible) not being altered so this standard does not apply. 10/19/2018 Page 1 of 2 ASPEN BUILDING DEPARTMENT Garrett oa4v2E,w Approved:Larimer n=' Residential Design Standardsii Administrative Compliance Review Staff Checklist NE CITY OF ASPEN Disclaimer: This application is only valid for the attached design.If any element of the design subject to Residential Design Standards changes prior to or during building permit review, the applicant shall be required to apply for a new Administrative Compliance Review. Iii Alt eAll LCompliance Comp)`, Sheet#(s)/Notes 111 .11111 C.4.Garage Door Design The existing carport contains two separate entrances, the remodel converts the Vi r carport to an encolsed garage and utilizes two separate garage doors that comply (Flexible) with option 1 of this standard, see sheet A3.3. D.1.Entry Connectionri r — Entry connection will remain street facing, see sheet A3.3 and A1 .4. (Non-flexible) D.2.Door Height Front door shown at 8', see sheet A3.3. (Flexible) rj r D.3.Entry Porch Entry porch measures approximately 9' which is less than one story as (Flexible) 1 r defined by this section, see sheet A3.3. E.1.Principle Window There is a group of windows that comply with the requirements of this (Flexible) V Fr section, see sheet A3.3. E.2.Window Placementk7 r No windows span more than one story, see sheet A3.3. (Flexible) E.3.Nonorthogonal Window Limitr No non-orthogonal windows are proposed on the street facing facade, (Flexible) see sheet A3.3. E.4.Lightwell/Stairwell Location There are not light wells proposed. (Flexible) r Materials are used consistentlyall sides thettur E.5.Materials on of sruc 6RE rE IVE D (Flexible) V E used true to their characteristics. L�J 10/19/2018 Page 2 of 2 ASPEN BUILDING DEPARTMENT