Loading...
HomeMy WebLinkAboutChange Order.1015 Waters Ave.0204.2019.ARBK 0204-2019-ARBK_BuildingCommentl 1.0 ChangeOrderDescrition.1015 Waters.ChangeOrder.2019.10.pdf(1) Subject: PlanCheck s,7,- .-Pt= ° Page: 2 I was unable to find the fireplace • ._,-.... �° p .: Author:justinh registration form, masonry ffl.,.,.iE._.."... 'tP'•P`°"v° Color: • fireplace specifications, or the File Name: 1.0 ChangeOrderDescrition.1015 new window/door package -_„_ .. Waters.ChangeOrder.2019.10.pdf information in the submittal ,_...„ documents. Please try Response:The fireplace forms and specs are attached, uploading these again when including a specification for the Isokern dedicated combustion resubmitting. air supply and the flu sentinel. A-Architecture.1015Waters.ChangeOrder.2019.10.pdf(20) Subject: PlanCheck � 'orJ ® ' ,. , : ^..�,Po^ Page: 8 Is 30"the height above grade or a n total height from top of wall to y b, Color:Author:justinh /r I am • bottom of footing. If the wall is Lot c �" File Name:A-Architecture.1015Waters.ChangeOrder.2019.10. taller than 48"from top of wall to - pdf bottom of footing a structural Vz */"1-; Response:A note has been added stating that the plan for the replacement is rid rtt:mtv"..m� retaining wall shall not exceed 4"from top of wall to required. Please confirm total t!N 'l' o bottom of footing. See L-1 wall height and provide kir��! additional detailing if necessary. ••--3•,m.•-- N„ tit•- Subject: PlanCheck,/ Snowmelt has been extended _� hq Page. 8 beyond the covered carport,this g Author:justinh T note should be updated Color: •■ �• n ��m "°E' • accordin ,t M.. _litFile Name: A-Architecture.1015Waters.ChangeOrder.2019.10. g y' • _.� I��� \��jig. pdf Mill ' f' Response:The Snowmelt locations have been revised. See Sheet A-002 for new snowmelt '"�x ii diagram and FEMP calculations. -:�I __V- Subject: PlanCheck �/ The utilit meters cannot v Page: 8 Y F — %.2e, C-,' # obstruct the required clear loeu°�;n Author:justinh p Color: • widths of the stairs or required re'"B ",Z -- landings, revise to comply. q^�a ^gs. " .,aaa" 9 p Y g_8•..eK.mow - , File Name: A-Architecture.1 015Waters.ChangeOrder.201 9.1 O. 'Retainin Wall - o df aoomo,wapo,, sea3� /'' Response:The utility meters have been relocated to the West Elevation. See A-202. x•= it .i7, Gara rea s� c a ^a S Mrtia e 'Wall Subject: PlanCheck Page: 8 This is a different model spa that Author:justinhNi was originally proposed for the Color: • roof deck. Submit specs that File Name: A-Architecture.1015Waters.ChangeOrder.2019.10. demonstrate it is REMP exempt it.,FigAm, .°..:47, pdf (must be 64 SgFt or less and �.: CEC certified)or include it on Response:The spa specified on the Landscape Plans are the REMP worksheet. '44 ` not correct. The spa originally prosed for the Deck is '� So� ae,ae,a,^^s-.4 correct. I have re-submitted the specifications. Provide a cutsheet on the spa iw `` ` " `"` ' cover that shows it complies with ASTM F 1346. RECEIVED 02/07/2020 ASPEN BUILDING DEPARTMENT Subject: PlanCheck REMP plan shows snowmelt Page: 8 Author:justinh only under the deck above, is a al he ca -» Color: • this actually the case? Please w^� t--? confirm and revise if necessary. File Name: A-Architecture.1015Waters.ChangeOrder.2019.10. ExlstingTrees l; /, pdf Terrace ^ ..d •� t Response: The Snowmelt locations have been revised. See Sheet A-002 for new snowmelt diagram and REMP calculations. Area Drain •name,baba" _ n ,'ll,-.' ' Subject: PlanCheck X Still has 1 spot that Page: 8 Three consecutive treads would Author:justinh needs handrails mean 4 risers,which requires a /,i compliant handrail per IRC per Color: ■ IRC 311.7.8, revise to comply. ..._. me ,1 File Name: A-Architecture.1 015Waters.ChangeOrder.201 9.1 O. 30 Reba Din Wall w ' T.I7 n� I.: />/ pdf simitutp & Gara Response:The walkway and stairs have been modified -/ ftil and the stairs are now limited to 2-3 risers, eliminating the need for a handrail. -vms iris:°: % See L1 to L-5 "' �P �, Auto Court " Subject: PlanCheck Handrails are required at this set Page: 8 X Still has 1 spot that of steps based on the number of /C, Author:justinh needs handrails risers. Provide a compliant �. Color: • Tr- - mi File Name: A-Architecture.1015Waters.ChangeOrder.2019.10. handrail and call out tread depth /�/ and riser height. Alternatively, if - � '' pdf you keep you stair runs limited to Response:The walkway and stairs have been Lot F a..=. �� ', 3 consectutive risers separated We' M /11 modified and the stairs are now limited to 2-3 risers, by compliant landings handrails eliminatingthe need for a handrail. See L1-L-5 Tp��° -// •" would no longer be required. /i Subject: PlanCheck The stone steps must be 36" Page: 8 Author:justinh wide to comply as a stair. You Color: • also need a landing at either �fl —`_°.,t� !rl side of the gate through the /j, File Name: A-Architecture.1015Waters.ChangeOrder.2019.10. � balcony railing. Revise the plan r / lqk pdf to comply. Lei. r _ ._ Response:The exterior stairs have been eliminated. See L-1 to L-5. (....."q:. Ili0 I„,,- :cV-5,0Qat i�� � �,�.m, Subject: PlanCheck 71 Page: 12 Originally approved set had a Author:justinh structural detail for the retaining 101-Retaining/Stone Fence Wall Section_ wall on L-5, include that detail on t. y,e.I, Color: • File Name:A-Architecture.1015Waters.ChangeOrder.2019.10. the revised sheet as well as that = `^,�„07„:„a _„ „,>� 2^=`,1•` pdf is still shown as part of the scope. Response:The retaining wall has been eliminated. See L-1 to L-5. RECEIVED 02/07/2020 ASPEN BUILDING DEPARTMENT _-_____ o_ Subject: PlanCheck ,/ Page: 13 $35620.76 was the amount = previously paid on your master _ Author:justinh -- _ ris: Color: • permit. Revise this form. -1 File Name: A-Architecture.1015Waters.ChangeOrder.2019.10. -----__'_ - pdf Response: This figure has been corrected on the REMP sheet. See A-002 Snowmelt and the 5 7 Attached REMP form. o-- r Subject: PlanCheck Page: 13 V Where is your property line in \\\ Author:justinh relation to the outer extent of the Color: • snowmelt? Any snowmelt in the ° L File Name: A-Architecture.1015Waters.ChangeOrder.2019.10. ROW must be on a separate pdf zone from snowmelt on your property. Show the property line Response: The Snowmelt areas have ben revised. in relation to this snowmelt, if MAIN See A-002 Snowmelt and the Attached REMP form. �m any is in the ROW note the There is no snowmelt in the ROW. requirement for it to be on a separate zone. Subject: PlanCheck Need detail for pervious ..o.oP��,P,.".,o„ F� Page: 13 paver hole pattern and The landscape sheets Author:justinh specifically call out pervious ° �u° q Color: ■ insulation thickness pavers in two snowmelted owg=„ E,. File Name: A-Architecture.1015Waters.ChangeOrder.2019.10. locations. Revise one plan or •r o o�G pdf the other so that what you are proposing is consistent between -- Response: The pervious pavers have been noted all sets. on A-002 Snowmelt Diagram and coordinated with the Landscape plan locations. I L A detail for snow melted pervious pavers has been added. The detail is courteous r . a of the Aspen Engineering Dept. I U Subject: PlanCheck Page: 13 Per your drawing I am r MAIN Author:justinh measuring 1079 sq ft of �// UPPEF Color: • snowmelt on the main level. oTAI File Name: A-Architecture.1015Waters.ChangeOrder.2019.10. Revise the plan or table and the Per your drawing am REMP worksheet if applicable. measuring 1079 sq ft pdf of snowmelt on the main level.Revise the R-Io Response: The Snowmelt areas have ben revised. plan or table and the REMP worksheet if 5N( See A-002 Snowmelt and the Attached REMP form. applicable. CC _t Subject: PlanCheck Page: 13 Why have you entered 64 SF of s Author:justinh exempt snowmelt? Please `� """" Color: • clarify or revise the form. hy have you entered ° °•' File Name:A-Architecture.1015Waters.ChangeOrder.2019.10. 64 SF of exempt ' - ' or snowmelt,seethe pdf a he orm Response: The Snowmelt areas have ben revised. See A-002 Snowmelt and the Attached REMP form RECEIVED 02/07/2020 ASPEN BUILDING DEPARTMENT DRIVEWAY Lu Subject: PlanCheck 3 Page: 16 This door requires a self-closing 0 Author:justinh device in addition to the 20 �T:o:r Color: • minute fire rating called out in File Name: A-Architecture.1015Waters.ChangeOrder.2019.10. the schedule, note this CoNOARY pdf requirement on the door °nAR E ® schedule. HOSEeS Response: The self closing Device required note has been I added to the A-602 Door Schedule 1-22-20. Subject: PlanCheck VWhat are you showing here? Page: 16 Author:justinh This is new to the plan, please Color: • clarify. File Name: A-Architecture.1015Waters.ChangeOrder.2019.10. 1 Maw 1 pdf ■I _II�■11�_111 #11 Response: This is a walkway and has been modified per this drawings. See L-1 to L-5. iNisselli - Subject: PlanCheck �/ 4 :�� m Page: 18 I do not see how this portion of g roof will drain properly. West Author:justinh Q I elevation does not show the Color: • cricket that is shown here. The File Name: A-Architecture.1015Waters.ChangeOrder.2019.1O. roof framing plan also does not ' ifl I pdf Response: A cricket has been added to drain match what you are showing l� to a collection box to a gutter on the West and East Side here. Clarify how this will drain ' of the building. See A-103 Roof Plan and properly and revise structure to 4 o A-202 West and A-204 East Elevations. The roof match. framing plan is coordinated for this over framed roof in this area. Subject: PlanCheck Page: 20 Per my measurements this E- ,E� Author:justinh masonry chimney does not a° "g. Color: • extend 2'above the roof �og' Ma• ;Rt;�3:s:ae. structure within 10', revise to File Name: A-Architecture.1015Waters.ChangeOrder.2019.10. T ° a T pdf comply with the requirements of IRC 1003.9. Revise to comply. 1 Response: The roof Chimney is14'-away from the roof 0 structure edge. Dimensions are added to show 0 IIIIIIIII� compliance, on A-202 West and A-204 East Elevation. Subject: PlanCheck �111_I gill o g I do not see how the finished fraiI! ! Page: ►mm�i�11 I ,m Author:justinh grade shown works with the RI f-lai u • Color: • stairs shown here on the „n.. ; "� io:, landscape plan. Show the stairs a�� �■ File Name:A-Architecture.1015Waters.ChangeOrder.2019.10. ii �#------- ' pdf to demonstrate how this will illwork. '' Response:The stairs at grade have been eliminated.The grade is shown correctly on A-203 South Elevation and L-1to ,,,,,,_ L-5 RECEIVED 02/07/2020 ASPEN BUILDING DEPARTMENT J H1, Subject: PlanCheck CLEARANCE INSTRUCTIONS Note the requirement for a Page: 28 dedicated combustion air supply t Author:justinh Color: • and either a flue sentinel or File Name: A-Architecture.1015Waters.ChangeOrder.2019.10. gasketed/sealed doors per City o. ,n r pdf policy. OM FIREPLACE PLAN =Ma°"`""°'^" Response: The Fireplace will be using a flu sentinel. ROOM FIREPLACE The specifications are attached. Show the dimensions of the tiff" = 1LO" required hearth extension. CLEAFANCEINSTRLCTIONC The Isokern dedicated combustion air supply is attached. The hearth dimensions have been added to the plan and fireplace details. M-MechanicalEngineering.1015Waters.ChangeOrder.2019.10.pdf(2) woEoN.wP�a�,aa�.aEH„"stars Subject: PlanCheck Page: [4] 18030 MECH-M1-4. You are no longer proposing the Author:justinh 8 bath exhaust fans that the You are no longer proposing the B bath exhaust fans that Color: • original whole house balanced the orlglnal whole house balanced ventilation calculation belzn ad'�„;a'�owP�'�d�°a� at�az�culzatloa ventilation calculation was based tie o tea,;ng,„at o" ea,e"r„a,a edw„ „oNee File Name: M-MechanicalEngineering.1015Waters.ChangeOr off, per my calculation you are entllation re°a;reroant. N°te°nt„eplan=t„atF-,,F.ganEFC.Ow;llbe der.2019.10.pdf o o°ti°"°"=,y;norderto„a,anret„e=nta O,„at no longer balanced within 20%. you eproposed xhaustfans tian<e,s;rollartowhat Provide an updated calculation Y°°I°"°r"°""a"'�"` Air balance calculation has been updated/corrected for the number of exhaust fans in the residence. demonstrating that you meet our Drawings were updated with the corrected balanced whole house calculation. outside airflow to the fan coils was ventilation requirement. reduced to balance the residence within 20%. The quantity of outside air still exceeds the required Note on the plans that FC 1, amount. Yes, fan coils and exhaust fans running FC-2 and FC-3 will be running continuously is still the proposed method of continuously in order to balance compliance. Ventilation and balance calculations the system if that is still the have been added to M1-1 for reference. proposed method of compliance, similar to what you noted for the exhaust fans. Subject: PlanCheck Page: [7] 18030 MECH-MP1-2. Revise the mechanical plans to Author:justinh match the new snowmelt plan. Color: • Update the mechanical Revise the mechanical plans . File Name: M-MechanicalEn ineerin .1015Waters.Chan eOr snowmelt schedule as well. match the new snowmelt plan. g 9 9 Update the mechanical der.2019.10.pdf snowmelt schedule as well. Bighorn: Mechanical drawings have been updated to match architectural snowmelt zone. Snowmelt schedule also updated per latest layout. See updated drawings dated 1-22-2020 RECEIVED 02/07/2020 ASPEN BUILDING DEPARTMENT