Loading...
HomeMy WebLinkAboutMaster Permit.1015 Waters Ave.0204.2019.ARBK 0076-2018-ARBK_BuildingComment2 17. 1015 Waters Additonal Special Inspection Signature Round 1.pdf(1) ^---_ _ Subject: PlanCheck =T= Page Label: 3 You still need the signature of Author:justinh your inspected fabricator for the — :� -- --- File Name: 17. 1015 Waters Additonal Special Inspection field welds shown in the Signature Round 1.pdf structural plan. Myers'signature Hf „.L:'7 as an approved fabricator only Color: • covers them for welding done withing their shop.You do not ' need to resubmit all sheets,just one with an inspected fabricator's signature. B-Building.PlanSet.1015Waters.2019.1.Roundl.pdf(4) Subject: PlanCheck / Page Label: £CH-V ROOF&ROOF DECK•50PLAN This exhaust location appears to be within 10'of the outdoor air Author:justinh shown on m File Name: B Building.PlanSet.1015Waters.2019.1.Round1.pd planks e(I can't say foe certain chanicalas 'nPl' ,_..m.P...a.. f the air intake is not shown on the ..... Color: • rw—nre elevations and this exhaust is 1 . not shown on the mechanical plan). Please revise or clearly demonstrate that you will have the required 10'of separation between the exhaust and intake. The 10'separation is not required if the supply intake is 3' or more below the exhaust termination,this may be the simplest solution. Subject: PlanCheck Page Label: 14"x 5.5" Concrete Border(Install to Provide these structural designs manufacturers specifications.) Permeable Pavers you reference here, they are not MSAM4Author:justinh currently in your structural set. File Name: B-Building.PlanSet.1015Waters.2019.1.Roundl.pd Any retaining wall 48"or more in f height(measured from top of wall to bottom of footing) Color: • „-- requires structural design. Subject: PlanCheck Page Label:A-003 GROSS& FIRE•50FLOOR The open to below area for the tiioiioiE9n It AREA•50CALCULATIONS upper level should not be Author:justinh counted towards your gross area 7■1 File Name: B-Building.PlanSet.1015Waters.2019.1.Round1.pd and the entry on the main level should be included (I'm 044 Color: • measuring 2216 lower level, 2180 main level and 1614 upper Atit fora total of 6010 SF). Please — revise your diagrams to have the tom proper areas shaded. u Subject: PlanCheck Page Label:A-101 MAIN ENTRY LEVEL•50FLOOR PLAN Where is the master bedroom I fireplace being exhausted? Author:justinh i �° w„ only see the living room exhaust \ o File Name: B-Building.PlanSet.1015Waters.2019.1.Roundl.pd shown on the roof plan and no the e f msee e!lying Color: • fireplace exhausts are shown on ;<,a"°"=Please the elevations. Please be sure m „« „„ ^ you are showing both. 5. M-1 0076-2018.ARBK_BuildingComment.BCE_Response_1.pdf(1) W7. Subject: PlanCheck Please provide the ventilation �P.. .. Page Label: 11 ---- = Author:justinh calculation referenced in these =.= responses, I could not locate --_ v................................................ File Name: M-1 - ~,-- - them in the resubmittal package. 0076-2018.ARBK_BuildingComment.BCE_Response_1.pdf Color: ■