HomeMy WebLinkAboutChange Order.1015 Waters Ave.0204.2019 (6).ARBK DATE:9-26-19 MASTER PERMIT:0076.2018.ARBK PERMIT NUMBER: , COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT APPLICATION THE CITY OF ASPEN PROPERTY INFORMATION , ADDRESS 1015 WATERS AVENUE ASPEN, CO. 81611 UNIT# PARCEL ID# 2737-182-82-002 LOT D and E BLOCK 41 TRACT OR SUBDIVISION EAST ASPEN ADDITION OWNER NAME EVELYN F HEMMING TRUST CELL 970-948-0846 EMAIL hemming@rof.net BEST CONTACT Gretchen Greenwood CELL 970-948-2081 EMAIL ggreenwood@ggaaspen.com NAME PROJECT DETAILS OF WORK IN DESCRIPTION D TAIL CHANGE ORDER 9-26-19 FOR PERMIT NUMBER.0076.BRBK.2019 TWO STORIES AB PROJECT $o.00 Use of Building Class of Work Fixture Counts Equipment Checklist VALUATION ❑ Commerical ❑■ New 0 Toilets,Bidets ' Forced Air/Gravity Systems SQFTOF 6,124SQ.FT. 0 Multi-Family ' Bathtub v WORK AREA ■ Single Family 0 Addition Lavatory(Wash Basin) —Wall,Suspended,or Unit Heaters ❑ g 0 Alteration Shower Gas Log UNIT SQ FT 6,293 SQ.FT. ❑ Mixed-Use 0 Repair I Kitchen Sink(+Disposal) Gas Appliancew LOT SIZE 0 0 IFFR z Dishwasher , Appliance Vents (SQFT) 6,000 SQ.FT. ❑ Tenant Finish I Laundry Bar,Utility Sink i Heat,Refrig,Cooling,or DISTURBED Will there be El Demolition 1—Clothes Washer Absorption Unit EXTERIOR AREA4,140 SQ.FT. anyroof wall ❑■ Change Order u Floor Sink g I Boilers(includes vent) penetrations? 0 z—Floor Drain ' Air Handling Unit NEW SQ FT N/A ❑■ Yes I Water Heater(Pan Req) 1 Cooling Systems QOJT ' #Gas Outlets TVentilation Fans WITH F Mao 6,124 SQ.FT. ❑ No ' Water Treatment —Range Hood Other . ZONE DISTRICT R 15 • #of Gas System Outlets i Snowmelt System Sq Ft 970 N Project Valuation:Cost of project as defined in Valuation Affadavit. NOTICE: This permit becomes null and Z Sq Ft of Work Area:Total square footage of area undergoing change or reconfiguration. void if work or construction authorized Unit Sq Ft:Gross Square Footage,not FAR,of permitted unit. is not commenced within 180 days,or ~ Lot Size:Total surveyed square footage of property. if construction or work is suspended or Y q g p p Y abandoned for a period of 180 days at Z Disturbed Exterior Area:Square footage of lot affected by permit application. any time after work is commenced. „, 'i New Sq Ft:Total added square footage for additions to net livable or net leasble space. p Sq Ft of Rooms with Utility Work:Total square footage,not FAR,of all rooms with plumbing work. Re- FOR CITY USE ONLY APPROVALS viewer SUBMITTAL FEES ISSUANCE FEES ISSUANCE FEES Department Needse Sign- Approved PC Permit Fee - Plan Check Parks Impact 419.65 Zoning x JPo 2/12/20 Zoning(50%) HPC Engineering School Ded. 435.24 Building Zoning(50%) CMP(50%) TDM Impact 46.97 Fire Engineering X HG 10/3 0/1 9 Energy Code REMP Ped.Amenity 0 CMP Plan Check Water CMP(50%) (Hourly) Housing Cash in Lieu Stormwater Zoning Sanitation Parks Review (Hourly) Stormwater Env. Health Utility Review Engineering City Use Tax Parks (Hourly) Landscape GIS County Use Tax Efficiency Approved Lot Area Deed Restricted To Issue Census Code # of Dwellings Plans Location Issuance ( CITY OF ASPEN December2017 Zu�r1�1u 130 S. GALENA ST ASPEN, CO 81611 1015 WATERS AVENUE ADDRESS: PERMIT NUMBER: COMMUNITY DEVELOPMENT DEPARTMENT [4 BUILDING PERMIT CONTACT SHEET THECnoPASrL, FOR PLAN REVIEW QUESTIONS Name GRETCHEN GREENWOOD Phone A E-mail igr'enWOOi . gga.sp-n.C.11l FOR INSPECTION QUESTIONS Name CHRIS HENDRICKSON Phone ,-• i E-mail 01 • r OWNER Name , , Phone -� Cell Phone Mailing 311 MIDLAND AVE. ASPEN CO. 81611 Address City State ZIP E-mail Address hemming@rof.net OWNER'S AUTHORIZED AGENT Name Gregg Hemming Phone -I • Cell Phone Mailing 311 MIDLAND AVE. ASPEN CO. 81611 Address City State ZIP E-mail Address hemming@rof.net APPLICATION BEST CONTACT Name GRETCHEN GREENWOOD Phone i IN -j Cell Phone Mailing Address 210 SOUTH GALENA ST. # 30 City ASPEN State CO ZIP 81611 E-mail Address ggreenwood@ggaaspen.com ARCHITECT OR DESIGNER OF RECORD Name GRETCHEN GREENWOOD Phone Cell Phone • • Mailing Address 210 SOUTH GALENA ST. # 30 City state ZIP ASPEN CO 81611 E-mail Address ggreenwood@ggaaspen.com CIVIL ENGINEER OF RECORD Name CHRIS HALE MOUNTAIN CROSS ENGINEERING,INC. Phone A A Cell Phone Mailing 826 1/2 GRAND AVE. GLENWOOD SPRINGS CO 81621 Address City State ZIP E-mail Address chris@mountaincross-eng.com STRUCTUAL ENGINEER OF RECORD ANDERSON STRUCTURAL ENGINEERING i- Name Phone Cell Phone Mailing 443 ELK RUN ROAD NEW CASTLE CO 81647 Address City State ZIP E-mail Address landon@anderson-structural.com GENERAL CONTRACTOR ' V- A-• A Name HENDRICKSON CONSTRUCTION Phone Cell Phone Mailing Address 1280 UTE AVENUE SUITE 5 City ASPEN State CO ZIP 81611 E-mail Address chris@hendricksoninc.com INSPECTIONS: The General Contractor must schedule inspections online. Please visit www.aspenpitkin.com/Departments/Community-Development-Forms/to do so. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction. I . my r sponsib. ty to review the approved plans and any comments that are contained thereon and see that the structure and/ proje s built i om liance with all applicable codes. Contractor 9/2 6/2 019 q Signature ` Date 0 7 'IFII ❑ Check if o re a tested own r uilder(single-family homes only).You must take a test and complete the owner%buildings a (CITY USE ONLY) Owner builder approved by: Date: Affidavit on�file /2 0 1,9 ( CITY OF ASPEN August2017 130 S. GALENA ST I ASPEN, CO 81611J BUILDING DEPARTMENT COMMUNITY DEVELOPMENT DEPARTMENT *it C=i oome oCOCuner Assocjaljon COo L , -p[ D© O('ri©J All land use applications within the City of Aspen are required to include a Homeowner Association Compliance Farm (this form) certifying the scope of work included in the land use application complies with all applicable covenants and homeowner association policies. The certification must be signed by the property owner or Attorney representing the,oroperty owner. Name: HEMMING EVELYN F. TRUST Property 970-948-0846 Owner("l"): Email: hemming@rot-net Phone No.: 970-948-0846 Address of 1015 Waters Avenue Aspen, CO. 81611 Property Lots D&E East Aspen Addition (subject of P application) I certify as follows: (pick one) FY4 This property is not subject to a homeowners association or other form of private covenant ❑ This property is subject to a homeowners association or private covenant and the improvements proposed in this land use application do not require approval by the homeowners association or covenant beneficiary_ ❑ This property is subject to a homeowners association or private covenant and the improvements proposed in this land use application have been approved by the homeowners association or covenant beneficiary- I understand this policy and I understand the City of Aspen does not interpret, enforce, or manage the applicability, meaning or/effect of rivate covenants or homeowner association rules or bylaws. I understand that this docu'n nt is blic document. Owner signature: I I / date: 2-(v .l c/ Owner printed name: GREGG HEMMING or, Attorney signature: date: Attorney printed name: • Ma./-PP.q.C7 17i l'L'v'of Aspen _so S. Ca E'2 SL. ice_ ,_ _ 10/10/2019 ASPEN • BUILDING DEPARTMENT [41lk ail,. smaszt irs .15 f4 ,. THE CITY OF ASPEN City of Aspen and Pitkin County '• FIREPLACE & WOODSTOVE REGISTRATION *Parcel Id number: 2 7 .3 7 -- l 8 2. -- ej 2 -- 2 O o 2 Street Address: /d/s makes AnnuG Owners Name: VEL yb'° f' IIEmingu4, Ti�[Csr *Required Contact Assessors offices at 920-5160 Registration will not be accepted without a Parcel Id number List all devices in your home(2 are allowed per building, except for gas appliances) Note:If the number, type and location on this registration form do not match what is show on your plans or what is actually installed,your permit or Certificate of Occupancy will be denied. Type of Building(circle one): Residential Other Type of device Room Existing New Make& Model Wood burning fireplace (select one) ?Site-built masonry ?Factory built insert:model number: Gas log fireplace W/V`/ n0 6/Y) (select one) ^ AL ?Site-built masonry ?Factory built insert:model / number: /5o&ERN m.96N1Qm 40 Certified woodstove Gas fireplace appliance D/9 j//IVC/ 171 (attach spec sheet) "S/ .546 BEb/Zotah'i eusrvrn F/2 e-et,ecE If any devices are being removed,please describe here, i.e. "old woodstove removed from living room" • • • Signature of appli Date G\city\building_dept\Aspen 2004 Checklists\fireplace registration _doe RECEIVED over 10/10/2019 ASPEN BUILDING DEPARTMENT Isokern Magnum 60" Fireplace earthcore is ;i(z/N 6899 Phillips Industrial Blvd.•Jacksonville,FL 32256 Project Name: 1015 WAFERS AVENUE Location: ASPEN,COLORADO 81611 Uses two Isokern DM 54 Chimneys or 14"Metal Chimney Pipe.Refer -- - -- - 531/2 1- - to product manual for approved ,- +--•25'/" Metal Chimney manufacturers. 10W ID0 25 A" ' ! 1 ARM 14" _ 1 Flue Outlet — I/MIK GO"Damper I 44 3" reo T P 2 3/ IItI tan"' Top View -. 85 3/e^ I 8" 1.11.11111M -I 1 - [-I 38" 28" 38" 41" 9I ± • 71 is____. z'%- I l I 73%z" 73,/z -- i _..-10 Vs" 5" Front View Plan View Side View MINIMUM FRAMING DIMENSIONS FIREPLACE OPTIONS Hearth Height: 49 Brick Type: 49 Brick Color. `I' Brick Pattern: Framing dimensions `I' 49 Damper: maintain 1 1/2" `I' Pe clearance to Chimney T combustibles. 871/a" ey Type: Refer to product manual for further Onset installation instructions. Other Options: Spark Arrestor/Termination: Enervex RSHT Chimney Fan: 291/2" Decorative Temiin ation: Gas Log Set 76'/z" :::: �E Al The total weight for the Magnum 60"fireplace is approximately 26521 ` i rx tLi', includes fireplace pumice components only,additional weight from m , rfip firebrick and chimney not included. 10/10/2C19 Rev.0816 ©2016 Earthcore Industries LLC ASPEN BUILDING DEPARTMENT Earthcore Industries MAGNUM 60-72 Series Fireplace Required Clearance to Combustibles A ) The MAGNUM Series fireplace and the DM chimney 4_I _ system is tested and listed for installation with"clearance to combustibles" as follows: .4,4 ,\� C� All DM 54 chimney components require 0"clearance. 44 %Oil (Figure 1) The MAGNUM Series firebox side walls and back 0 wall require 1 1/2" clearance. (Figure 2) 11411441444 < The smoke dome front wall requires 0" clearance. 0"Clearance ` IIIIII `+ '` NOTE: "Combustibles" are defined as "normal / construction materials" and are considered to be: wood 111111111111 framing materials, particle board, mill board, plywood �\ sub-flooring, plywood paneling and wood flooring. 0"Clearance MAGNUM Series fireplaces are tested and listed for ' (1 1/2") clearance to combustible framing material at the firebox sides and back. Installation and use practices that are beyond the I� , , control of the manufacturer*can result in situations where I—\ /,, clearance requirements (as determined through testing / and as stated by the manufacturer) are not maintained due to construction subsequent to the installation of the � Isokern unit. It is the general contractor's responsibility to assure that listed clearances to combustible framing and I to insulation are maintained throughout the construction I/ of the project subsequent to the installation of the Isokern unit. 00•101 To avoid causing a fire resulting in damage to property, personal injury or loss of life, do not pack or fill the required air spaces with insulation or other material. FIGURE 1 ,11111 No material is allowed in these areas. (Figures 2&3) Keep all insulation, vapor barriers, "house wrap" paper and other insulating type membranes and products, including fiberglass, cellulose and other insulation, (anything that carries an "R" rating) a minimum of three inches (3")away from all firebox and chimney surfaces. IMPORTANT The manufacturer is not responsible for installation and use practices that are beyond the scope of the product as defined in the product listing and in this installation manual. 1f" Min. ri,' I: :-_� COMBUSTIBLE Sheathing materials, such as plywood, particle FRAMING board and drywall may cover the smoke dome front at // �+.+ 0"' clearance_ All combustible sheathing materials that .� I protrude beyond front of firebox: 1y" IN // -'. 1�- Models 60&72: Min. // +j. Min. ll , •, • Sides: 9" (nine inches) away _aim , / ''., ,� •Top of opening: 24"(twenty-four inches)away —I MIN I— Drywall must be cut back from the firebox opening sides and above the top of the opening according to information 9"=60&72 above. FIGURE 2 ti'' (� it 10/10/20 9 12 ASPEN BUILDING DEPARTMENT w • • 1 iaVinci CUSTOM FIREPLACES it 1 , lit il, . ,.It ,11111 •'- ,...y. 4 . i f it , . . . . . , . ; :.,,,, .., ,. .. . . _.,..... . . .i • . f I •• _ - 4 r c .� • 10 10 2019 Category I Fireplaces - 3 Ft to 6 Ft ASPEN BUILDING DEPARTMENT itV ii . 1II aVinci Custom FireplacesTM The most innovative and unique fireplaces ever made ~�`"'"" "_ DaVinci is a fusion of fire and iconic, contemporary .r.;-a- v.. design — The epitome of the perfect decorative, non-heating -- _ T- custom gas fireplace in all areas of design, innovation and - functionality. With DaVinci, there are no design limitations. The breathtakingbeautyand style of a DaVinci Custom . ` ' 'm:,.�. Fireplace will create a dramatic focal point in any room. A - . �: -3-- , sleek, contemporary profile features an all-glass viewing .: _- fi -4. p Y 9 `_ --ate __ Y • area that surrounds a ribbon of rich, dancing flames. _ --•_ _ _ ' •4-�s- DaVincl s signature fire presentation draws you in with its striking presence of mesmerizing flames over a bed of ' Z ...-'' ix _ ) e • • �' 1. -- =� ' _ -�° : ,� .--ram--- --� Platinum* reflective crushed glass with adjustable vibrant - - 1' __ _ multi-color LED lighting. �` •«ri 9 9 ems,•=;r ''` ".," *Black Glass and Rock Embers also available. ' -ITS� .p-I qk r J ...,t --3 ' . - �. �; A _ Iii. r �, _ Iita\7111C 4. I !Ile tonpfe _ _ ,....2_ ,.....„ 2 ASPEN UUiLDING DEPARTMENT Contents DaVinci Custom Fireplaces° range in length from 3 to 6 feet, and feature five different ""''•'`�" glass heights of 12", 20", 30", 36" and ------- — -- NOW 58" inches. Tantalizing Features Special features of the DaVinci 4-12 Product Information Single-Sided Fireplaces 13 1 Right & Left Corner Fireplaces 14 Bay Window Fireplaces 15 Pier Fireplaces 16 See-Thru Fireplaces 17 Island Fireplaces 18 Venting 19 .07 airivv""/!;:;; ;NA ,7 Watch a short video •'. on how DaVinci Custom -�, r - �i • , . Fireplaces are made. . RECEIVED 10/10/2019 davincifireplaces.com ASPEN 3 BUILDING DEPARTMENT .��r,1� ,, • Dolafe Touch GIassTM - i r '. . . _ . Your safety is our number , - , - - �, one concern. InnovativeAPI engineering keeps our double-pane, crystal clear , , 411111. glass at extraordinarily low 0 temperatures, reducing ,v5t0,:iiipp, any potential for injury. • This standard safety feature on every DaVinci Custom , I Fireplace makes them ideal for I decorative home applications .4[1( .. \ r 'and high traffic commercial - s , " i• installations. Iiii„r . ...t. -49- • •M REC D , . 10/10 19 4 ASPEN BUILDING DEPARTMENT 7,`,, ero Clearance To Combustible Surfaces The fireplace's exterior remains cool to the touch from the outside air that is ducted to the fireplace. This eliminates the use of expensive non-combustible building materials and gives you the freedom to finish right up to the edge of the glass with any building materials you desire. 41‘ 11 I( ,p_ti,J F. . . A , „,_,,,.... ,...........____ ... ih1/4.' 11111h!e _.•' \ \\, ,... . . ., kliik c. _ .,. ___ 1 . ‘a, r ' c - - nil , f • -: IL I i , Sheetrock Wood Tile or Stone Bring the clean finish edge of sheetrock Any wood finish of your choice can be Use Hardy Board siding or attach up to the glass or use our custom black installed right to the edge of the glass. stone or tile directly to the fireplace. =MED painted metal trim along the top edge. Stone or tile can go right to the edge • 10/10/2019 davincifireplaces.com ASPEN 5 BUILDING DEPARTMENT 514 I, eatures • Manufactured in Mukilteo, WA by Travis • DaVinci Custom Fireplaces are the finestIIP Industries, North America's premier engineered fireplaces, and feature manufacturer of hearth products. heavy gauge steel construction and the • Winner of the prestigious highest quality materials available. Hearth Industry VESTA Award ' " • Award winning TouchSmartTM wall control _ — A for Best New Gas Fireplace inw..•-. system, simple North America. to use andI I • • Manufacturing is extremely efficient, cutting elegant in i lead times down to 4-6 weeks,which is half design. \ — _ _ — of the custom fireplace industry standard! • Innovative modular design makes DaVinci • Approved for covered outdoor installation. . the easiest custom fireplace to deliver and See-Thru models can be built into an install at the jobsite. exterior wall using our Exterior Window Kit — • 14,500 BTUs per foot input. • Zero clearance to combustible surfaces. • More than 500 individual custom • Quiet power vent exhaust system1 r fireplace designs to choose from. accommodates vent runs up to 150 feet 1,1L' - 12", 20", 30", 36"and 58"glass heights. long. The exhaust vent can terminate - Order by the foot in lengths from 3 to 6 feet. above, to the sides or below the fireplace. - Seven Fireplace Designs: Single-Sided Fireplaces • Choice of vertical or inline horizontal power Right Corner Fireplaces vent fans. Left Corner Fireplaces • Non-heater decorative fireplace rated. See-Thru Fireplaces b Bay Window Fireplaces Tested and listed to: -.1! Pier Fireplaces ANSI Z21 .50b-2014 / CSA 2.22b-2014 Island Fireplaces • Optional heat exchanger available for • Platinum reflective crushed glass floor with applications requiring room heat. \. , D multi-colored LED lighting or NEW Black Glass or • U. S. and Foreign Patents Pending. Ember Rock media options (see page 10). 6 ASPEN BUILDING DEPARTMENT 1 i l -!.. ,- __ .- L. . , . 7 lir - 1 I k : I , _ _ ,, . , Ile : __..,, i . iii-O. id -,- -. --- . -_-., , _. , . f(11. Pity.1 0 60" (5 foot) See-Thru fireplace with 20"tall glass . D Enjoy the beauty of the fire without the heat or add the optional heat exchanger if heat is desired. 19 davincifireplaces.com ASPENS BUILDING DEPARTMENT poi Mol even Models Single-Sided Left Corner Right Corner 1 ,�. 1� ��JI , , ►t iAii. iii..1, 11,E,1 4 DaVinci Custom Fireplaces TM are available Bay Window Pier in seven different models, allowing you to create a fireplace with a design configuration that will architecturally iit,,,, ,,I _ , t 4‘, Ild 1 complement any space. • Single-Sided & See-Thru models: Lengths range from 3 feet to 5 feet. • Right Corner, Left Corner & Pier Models: Island See-Thru Lengths range from 3.5 feet to 5.5 feet. al • Bay Window & Island Models: Lengths range from 4 feet to 6 feet. ati RECEIVED 10/10/2019 8 ASPEN BUILDING DEPARTMENT I ive Glass Heights All seven DaVinci models feature the choice of five different glass heights, which range from a sleek 12 inches tall up to a massive 58 inches tall. ARAI 141 11 ‘11," • 12" Glass Height 20" Glass Height • 11111111 tI 30" Glass Height 36" Glass Height 58" Glass Height 10/10/2019 davincifireplaces.com ASPEN 9 BUILDING DEPARTMENT pr '! i . • \ f i ,fill ., 411' Ir lit , . 44 . 1_ _ . 4' - -- .. , . .. -. _ ,, ._. likt,t "- - ;* Platinum Crushed Glass showing variations of colored LED lights NEW NEW Black Crushed Glass Rock Ember Option Option multi-Colored Interior LED Lighting DaVinci's Platinum crushed glass floor is under-lit with vibrant colored LED lights that take this fireplace to a whole new level when illuminated. An endless array of vivid colors is at your fingertips, allowing you to set the mood and create the perfect ambiance for any occasion. The burst of color adds a mesmerizing glow around the flames and reflects off the crushed glass floor to create a dramatic presentation of fire unlike anything you've ever seen. Looking for a more subtle organic look? DaVinci Custom Fireplaces now offersEIVED Black Crushed Glass or Rock Ember options. 1 O/1 O/2 O 19 10 ASPEN BUILDING DEPARTMENT 1iini OM pgrade Options Choice of Optional Liners ,' " Al , i 111/ These contemporary liners provide a dramatic backdrop to the dancing flames of your DaVinci. Standard Black Paint Finish Silver Paint Finish Black Porcelain Finish Choice of Optional Trim Accent your DaVinci with the 2" Black Trim or the hand-hammered IronWorksTM Trim. © : , ' The IronWorksTM Trim is both a showcase of craftsmanship and a true work of art . individually made by our talented in-house blacksmiths. Each IronWorksTM Trim r--::. features hand-hammered, textured surfaces and intricate detailing. ` The lronWorksTM Trim is available in your choice of hand-rubbed Bronze Patina '_ . ; ,_ or Burnished Patina. These finishes are hand-applied by skilled artisans and are I absorbed deep into the metal, giving a rich luster and imparting a unique look with Bronze Ironworks° Patina Ironworks° 2" Wide no two finishes exactly alike. Black Painted Heat Exchanger Kit Exterior Window Kit 41 While DaVinci Custom Fireplaces are primarily designed as The DaVinci Single-Sided and See-Thru a non-heating appliance, there are occasions where heat i' il, models are now approved for Indoor/ is desired. 4 ,_ . • Outdoor Installation. This installation r. DaVinci Custom Fireplaces makes a heat exchanger '' requires the NEW Exterior Window Kit. add-on option that allows you to vent heat in the room _ --- `-- .7"*"— ::-,__^ The Exterior Window Kit can accommodate where the fireplace is located, or into a nearby location k. - fireplaces up to 6 feet in len th and can within the building. �- be used with 12, 20, 30, 36iE'r VED The heat exchanger is not currently available for Bay '� ti ,. tall glass. and Island fireplaces. 10/10/2019 davincifireplaces.com ASPENI 1 BUILDING DEPARTMENT r I !\ Choice of Optional Fyre-ArtTM P 111 re Art TM Transform the overall look of your DaVinci with one of these transitional Fyre-ArtTM options. We craft our Fyre- ArtTm based on pieces of driftwood and time worn stones to offer the most detailed and realistic media available. Ilk. ..0 ' 4 P i iii , . , t , . . -. , , ,,, .. .; _. _ ....,....r..... . Traditional Log Set Driftwood Log Set W IIEL111Ei III !Ill i It. l / ' r , . if. talk iii -, ' Of ki_i_IA till) ,... Birch Logs - 20" Glass Models Only Twig & Stone Kit . i ik i , ... i . LA. i i II IPIP: I 1 11 OP )11111171 -I . )1 I I lilt 1 i 1111 ON 14 if 146 • i 4 .4!i. 41It 411$ 0 . IF i s r , . . . ,, i .4,) I ‘ ' 1 ' '1. '-' , . r ro., - it .--,, • 414% gio.14. . Bamboo Logs - 20" Glass Models Only Tumbled Stone Kit 10/10/2 019 12 ASPEN BUILDING DEPARTMENT The sleek simplicity of this fireplace lends itself to a wide range of applications and has the r-�1 ability to complement any residential or commercial space with its clean, dynamic view, and a �;;� fire that will not overheat your dinner guests. Available in one foot lengths from 3 feet to 5 feet. i ngl 'e-Sided Choose 12", 20", 30", 36" and 58" tall glass. IV ' •' tit MI 1 11111 il' \ 04'\1000 , \,, , .,, . t \ 417r „ ,. : , rirlilliii iv „4 „--i. _ ___ I 41 \ -, - This horn setting features a 60 inch (5 Ft) Single-Sided Fireplace with 20"tall glass 19 davincifireplaces.com ASPENI3 BUILDING DEPARTMENT i WIIht This eye-catching corner design adds visual depth and dimension to the fireview, while architecturally complementing a variety of applications. The modular design of the DaVinci 1 igq allows us to custom build Corner Fireplaces in one foot lengths from 3.5 feet to 5.5 feet and in• o r Left Corner 12", 20", 30", 36" or 58" glass height- NOW COMES POSTLESS! 4 . f IIE ril 1 L HT � ' •;*ice' :4) I ll I _ k1 N' _ t i- /. _____ _ , 54" (4.5 ft) Right Corner fireplace with 20"tall glass REC El D 10/10/2019 14 ASPEN BUILDING DEPARTMENT ` .III This fireplace features a contemporary three-sided glass design that showcases the fire from multiple k view points and provides a dramatic focal point to any room. Available in one foot lengths from 4 feet to ayWindow 6 feet and your choice of 12", 20", 30", 36" or 58" tall glass. NOW COMES POSTLESS! r 1= � IrAkkE 1111_111 • .0 41004 • -= . RECEI � D 72 Inch (6 ft) Bay Window fireplace with 12 tall glass _ _ 10/10/2 s'19 davincifireplaces.com ASPENI5 BUILDING DEPARTMENT ila The unique architectural design of this fireplace serves as a beautiful focal point that can be used to divide a large living space or integrate two smaller spaces. Available in one foot lengths from 3.5 feet to 5.5 feet and in 12", 20", 30", 36" or A 1. ier 58" glass heights. NOW COMES POSTLESS! _______ _mill . . •s ,4:,, fri. Li., ...._...... i- r a atifilfita;......,...- ,eg ..< P r . "T I �. _•Oti, f •• ?o - ' 54 Inch (4.5 ft) Pier fireplace with 20"tall glass :I) �„ `f i/41 I Si� �.X - 10 10 2 r'i 16 ASPEN BUILDING DEPARTMENT r�' The See-Thru can serve as a stylish viewing window between two rooms, or provide a breathtaking display of � T h rU fire to the center of large rooms and outdoor living spaces. Available in one foot lengths from 3 feet to 5 ee— feet. Choose 12", 20", 30", 36" or 56" tall glass. , --1111111W1la -- 10,:t;Ii i..... � . I . , ) __, ., . ,,. it .. _ • __,,„.. . i • 4 ,1144.1440k. CO:\t4 ‘ 40ii , -----m. I . • ItA-.. . ` Pr ili*z_N_ \),,1 - Ia ,, Indoor/Outdoor 60 Inch (5 ft) See-Thru fireplace with 36''tall glass ...., _.. ...._ ... x - 19 davincifireplaces.com ASPEN 7 BUILDING DEPARTMENT The Island makes a stunning focal point for the center of any living space, as it features a 360 degree wrap-around Island fire view that can be enjoyed from any angle in the room. Available in one foot lengths from 4 feet to 6 feet and choice of 12", 20", 30", 36" or 58" tall glass. MR mak 4141IN —i swim.°l#,J _i___ „ .... . ..moot ‘ 4, �� implepp. ' — •..........., ....,,,,,, ___ griici iliiiiii,A.. . Ihr----- .7.,.., :4;61111.111111.=1- I 11\ r7441 72 Inch (6 ft) Island fireplace with 20"tall glass D 1 9 18 ASPEN BUILDING DEPARTMENT ' enting All DaVinci Custom Fireplaces are power vented. A quiet power vent exhaust system pulls combustion air into and around the fireplace while at the same time pushing combustion gases through the exhaust vent and out of the building. This system solves all venting challenges and accommodates vent runs up to 150 feet long or 3 feet below the unit, allowing you to install a DaVinci anywhere your imagination pictures it. --11/ MIER 13 ;ial Vertical (Roof Top) Power Exhaust Vent Fan Termination Check with your local building codes for snow pack height requirements, Horizontal Termination Online Power Exhaust Far ECEIVED 10/10/2019 davincifireplaces.com ASPEI19 BUILDING DEPARTMENT Custom "L" Fireplaces By DaVinci - No Limitation ! !ill II %. , 1 G * 4. 1 ll JO 1.-..7 . ' Lis ' -'' • = - - . — .Y,: - - r . .).s The "L" is a larger than life new fireplace by DaVinci. As the name "L" suggests, this fireplace ARONT features a 90 degree turn of dancing flames extending in opposite directions, creating a stunning and architecturally unique presentation of fire. ARCAT.com is the most used FREE building product With The "L" you have the ability to feature a fireplace with single or multiple 90 degree right and information website. All of left corners of fire that can be configured as a Single-Sided, See-Thru, Bay Window, Island, Pier or DaVinci's spec information Corner fireplace with any length sides you desire and glass heights ranging from 12 — 58 inches tall. along with DWG and DFX drawings are listed on ARCAT and can easily be downloaded. I IW Search under Travis Industries uaVinci or use QR Code El 0 0 on you Custom FireplacesTM phone r FeEla aT See our complete line of fireplaces or tablet. E_ l �•� ED •Visit us online: davincifireplace.com We reserve the right to change and improve our product at any time without prior notification. Please refer to the Owner's Installation Manual for complete installation requirements. 0o 22 Photos and illustrations are for descriptive purposes only.Copyright T.I. 09/2016 O 1988 OT38o 20 ASPEN BUILDING DEPARTMENT DaVmci Custom FireplaceTM STYLE: RIGHT CORNER 66"x 30" Electrical Req'd-7A 120V Gas Req'd-72,500 BTUs NG-Mn=5.5"wc (1.37kpa), Max=7"wc(1.74 kpa) LP - Mn= 11"wc(2.74 kpa), Max= 13"wc(3.23 kpa) 67" 913/16' r INTAKE EXHAUST 31" 19 5/8" 10 3/8" r 1 - - 59 3/16" 30" RECEIVED 111/8" ❑ ❑ 10/10/2019 t u u ASPEN BUILDING DEPARTMENT DaVmci Custom FireplaceTM STYLE: RIGHT CORNER 66"x 20" Electrical Req'd-7A 120V Gas Req'd-72,500 BTUs NG-Mn=5.5"wc (1.37kpa), Max=7"wc(1.74 kpa) LP - Mn= 11"wc(2.74 kpa), Max= 13"wc(3.23 kpa) I 67" I - 9 id r INTAKE EXHAUST 40 31" 19 5/8" 10 3/8"T 1 49 3/16" 20" RECEIVED 111/8" CIEl10/10/2019 t u u ASPEN BUILDING DEPARTMENT DaVinci Custom Fireplace1M STYLE: BAY 108" x 30" boig% Electrical Req'd- 7A 120V Gas Req'd- 116,000 BTU's q_,Iv)) . ._ NG - Min = 5.5"wc (1.37kpa), Max= 7"wc (1.74 kpa) LP- Min = 11"wc (2.74 kpa), Max= 13"wc (3.23 kpa) ci ir 108" — 4 iIII E E 11 9 13116" 4 f O ETNTAKES 0� 46 7116" 1• 46 7116"30"Fs- 19 518" 13 9116" m m HT HT 1 II II 60 5/8" 3 in RECEIVED 10/10/2019 12 5/8" p ,o oa, 0 rl , Irl- ASPEN BUILDING DEPARTMENT 2015 IECC RESIDENTIAL RENEWABLE ENERGY MITIGATION PROGRAM CITY OF ASPEN VERSION III UPDA IlB MARCH28 201/ PROJECT ADDRESS: 1015 WATERS AVENUE Parcel ID#: 2735-124-59-112 Permit Number: 0076.2018.ARBK CONTACT INFORMATION : Owner: Name: EVELYN F.HEMMING FAMILY TRUST City: ASPEN Address: 311 MIDLAND AVE. State: CO Email: hemming@rof.net Zip Code: 81611 Phone: 970-948-0846 Cell Phone: 970-948-0846 Owner's Representative: Name: GRETCHEN GREENWOOD City: ASPEN Address: 210 SOUTH GALENA ST.#30 State: CO. Email: ggreenwood anggaaspen.com Tip Code: 81611 Phone: 970-925-4502 Cell Phone: 970-948-2081 A_ RESIDENTIAL RENEWABLE ENERGY MITIGATION PROGRAM Sheets showing snowmelt, pool,spa,and solar/GSHP information: A-002 1015 WATERS SNOWMELT PLAN&DETAILS Do you have snowmelt or a spa that has been exempted by the buiding official? O Yes(enter sqft below on the exempt row) 0 No Hydro Snowmelt Electric Snowmelt Pool Spa Existing To be Removed Existing to Remain 0.00 sqft 0.00 sqft 0.00 sqft 0.00 sqft New 1500.00 sqft New(exempt) 64.00 sqft Total on site 1564.00 sqft 0.00 sqft 0.00 sqft 0.00 sqft Total Snowmelt on site 1564.00 sqft Boiler Efficiency 95.0% 100% 75.0% 75.0% Mitigation Fee $53,684.21 $ - $ _ Total Fee for Mitigation: $ 53,684.21 B. ON-SITE RENEWABLE CREDITS Supplemental System REMP Credit Use PV Worksheet Photovoltaic System $Use Thermal Worksheet Hot Water Panels $Use GSHP Cert Ground Source Heat Pump $ - Other Approved System $ - Total Mitigation Credits: $ - Onsite Renewable Offsets: How many Kilo Watts of PV(solar electric)would I need? 7.82 or How many square feet of SI-lW(solar hot water)would f need? 238.97 R-REMP Fee: $ 53,684.21 Amount Previously Paid on This Permit: $ 35,627.76 $ 18,056.45 Refund(includes minus$750): $C. PREPARED BY: Date: l Print Name: Gretchen Greenwood Signature: ._ Phone&EMail: 970-948-2081 ggreenwood@ggaaspen_com RECEIVED REVIEWED: Date: 10/10/2 019 ASPEN BUILDING DEPARTMENT Quote Creation Date: 9/26/2019 western Quote Expiration Date: 9/26/2019 window systems Quote Order Date: Quote Not Ordered westernwindowsystems.com CUSTOMER QUOTE 303880 r\_ w A� f �,.� Zvi 4 l��r �� ' TT1 •,, , ,~ � j t. 0�,4,.., a , j PP, ,,i \ i'.r �7Y7 '4,1 4,1i.11,-, * . 40.... --. , _..._ - ..0 _ ii. ...2.1011 MS 1:/* it I R 1F, 1 f`j I _ • -_ f.d mil' iM E. Presented by Mountain View Window & Door, Inc. - Grand Junction 1015 Waters / Hendrickson/ Greenwood Quote Name: Copy of CustomView- Quote Estimated Ship Date: Quote Not Ordered PO Number: Bid by: Ship Via: Billing Information Customer Name: Phone: Address: Fax: Contact Person: Shipping Information Address: Phone: Fax: Contact Person: RECEIVED printed by Carlie Urell Page/1 20191 of 6 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered I.ro windows stems Quote Name: @otfyIS OdstomView-Quote Ship Date: y westernwi n dowsystems.com PO Number: Ship Via: Bid by: Line Item Quantity Net Price Extended Price 1 1 Outside View(Scaled to Fit) Line Item Quantity Net Price Extended Price 1-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Kitchen (A) Fixed Special PRODUCT TYPE Row 1:Series 7630 Direct Set 82.125 x 26.375 Row 2:Series 7630 Direct Set 82.125 x 26.3125 Row 3:Series 7630 Direct Set Trapezoid 82.125 x 68 Unit 1: Frame Width=82.125, Frame Height=26.375 • Unit 2: Frame Width=82.125, Frame Height=26.3125 Unit 3: Frame Width=82.125, Frame Height=68, Frame Short Side=42 Unit 1,2: Complete Unit,Standard Sill,Compensation Channel?=No,Performance Sill Pan?=No,Shipped, and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No I Unit 3:Complete Unit,Standard Sill,Compensation Channel?=No,Performance Sill Pan?=No,Shipped, } and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No,Trapezoid Head Length=87.642,Trapezoid Head Angle= 17.567, Facing Dimension=Right COLOR OPTIONS 1 - Split Finish=No, Bronze Anodized 81 II5 GLASS OPTIONS Unit 1,2,3:Glass Provider=Cardinal,Glazing Type= Insulated Low E Triple Pane,Cardinal 366,Cardinal i89 on Surface 6=No,Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer,Black Spacer Color,OA Glass Thickness=1.6"OA (5mm/.51"/5mm/.51"/5mm),NFRC Unit Glass Strength=Annealed Unit 1,2,3:Annealed Glass,Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm) HARDWARE OPTIONS Coastal Stainless Package NFRC U-Factor=0.22, U-Factor-Metric= 1.25,SHGC=0.22, CR=74,VT=0.49,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-41-00008-00022, ENERGY STAR: Northern=Yes, ENERGY STAR: North-Central=Yes, ENERGY STAR:South-Central=Yes, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Shipped Loose, Drip Cap Cut Length=91 Wrapping-Mull Options Mull Method=Verticals Run Thru RECEIVED printed by Carlie Urell Pag/2 of 2 619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered Window s stems Quote Name: @ottylS a4astomView-Quote Ship Date: PO Number: �� y westernwindowsystems.com Ship Via: Bid by: Special Order Notes: this unit will be mulled to the bottom of Kitchen A trap WINDOW IS APPROVED WITH HORIZONTALS RUNNING THRU *need U values for this unit Warnings: Due to argon gas leakage, NFRCs will display as if Air was selected when combining Capillary Tubes with Argon Gas. Line Notes: Weight(Ibs): 589.3452 Line Item Quantity Net Price Extended Price 2-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Entry(B) PRODUCT TYPE Row 1:Series 7630 Direct Set 162.25 x 69.71875 Row 2:Series 7630 Direct Set 162.25 x 26.375 Row 3:Series 7630 Direct Set 162.25 x 69.71875 Unit 1,2, 5,6: Frame Width=81.125, Frame Height=69.71875 Unit 3,4: Frame Width=81.125, Frame Height=26.375 g R Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1,2,3,4,5,6:Glass Provider=Cardinal, Glazing Type= Insulated Low E Triple Pane,Cardinal 366, Cardinal i89 on Surface 6=No,Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary 81136 81136 Tubes,with NEAT=No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1.6"OA 162=6 (5mm/.51"I5mm/.51"/5mm),NFRC Unit Glass Strength=Tempered Unit 1,2,3,4,5,6:Tempered Glass,Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm) HARDWARE OPTIONS Coastal Stainless Package NFRC U-Factor=0.22, U-Factor-Metric= 1.25,SHGC=0.22, CR=74,VT=0.49,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-41-00008-00022, ENERGY STAR: Northern=Yes, ENERGY STAR: North-Central=Yes, ENERGY STAR:South-Central=Yes, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Shipped Loose, Drip Cap Cut Length=170 Wrapping-Mull Options Mull Method=Verticals Run Thru Special Order Notes: Warnings: Due to argon gas leakage, NFRCs will display as if Air was selected when combining Capillary Tubes with Argon Gas. Line Notes: Weight(Ibs): 1566.664 RECEIVED printed by Carlie Urell Page/30of 2619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered windOW S stems Quote Name: @otfyIS OdstomView-Quote Ship Date: PO Number: �� y westernwi n dowsystems.com Ship Via: Bid by: Line Item Quantity Net Price Extended Price 3-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Entry(C) Fixed Special PRODUCT TYPE Row 1:Series 7630 Direct Set 82.125 x 69.71875 Row 2:Series 7630 Direct Set 82.125 x 26.375 Row 3:Series 7630 Direct Set Trapezoid 82.125 x 68 Unit 1: Frame Width=82.125, Frame Height=69.71875 Unit 2: Frame Width=82.125, Frame Height=26.375 Unit 3: Frame Width=82.125, Frame Height=68, Frame Short Side=40.75 • Unit 1,2: Complete Unit,Standard Sill,Compensation Channel?=No,Performance Sill Pan?=No,Shipped, and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No Unit 3:Complete Unit,Standard Sill,Compensation Channel?=No,Performance Sill Pan?=No,Shipped, and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No,Trapezoid Head Length=88.028,Trapezoid Head Angle= 18.356, Facing Dimension=Right COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1,2: Glass Provider=Cardinal,Glazing Type= Insulated Low E Triple Pane,Cardinal 366,Cardinal i89 on Surface 6=No,Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer,Black Spacer Color,OA Glass Thickness=1.6"OA (5mm/.51"/5mm/.51"/5mm),NFRC Unit Glass Strength=Tempered Unit 1,2:Tempered Glass, Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm) Unit 3:Glass Provider=Cardinal,Glazing Type=Insulated Low E Triple Pane, Cardinal 366,Cardinal i89 on Surface 6=No, Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT= No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm), NFRC Unit Glass Strength=Annealed Unit 3:Annealed Glass,Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm) HARDWARE OPTIONS Coastal Stainless Package NFRC U-Factor=0.22, U-Factor-Metric= 1.25,SHGC=0.22, CR=74,VT=0.49,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-41-00008-00022, ENERGY STAR: Northern=Yes, ENERGY STAR: North-Central=Yes, ENERGY STAR:South-Central=Yes, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Shipped Loose, Drip Cap Cut Length=91 Wrapping-Mull Options Mull Method=Verticals Run Thru Special Order Notes: this unit will be mulled to the bottom of Entry C Trap as indicated in attached pic. I will also need u-values for this complete unit WINDOW IS APPROVED,HORIZONTALS TO RUN THRU Warnings: Due to argon gas leakage, NFRCs will display as if Air was selected when combining Capillary Tubes with Argon Gas. Line Notes: Weight(Ibs): 774.9659 RECEIVED printed by Carlie Urell Page/4 of 2 619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered windOW S stems Quote Name: @otfyIS OCIstomView-Quote Ship Date: y westernwi n dowsystems.com PO Number: Ship Via: Bid by: Line Item Quantity Net Price Extended Price 4-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Living Room (D) Special PRODUCT TYPE Series 7630 Direct Set Trapezoid 108 x 58.03125 Frame Width= 108, Frame Height=58.03125, Frame Short Side=22.03125 Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No,Trapezoid Head Length=115.342,Trapezoid Head Angle= 18.435, Facing Dimension=Left • COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1:Glass Provider=Cardinal, Insulated Low E,Cardinal 366,Cardinal i89?=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer, Black Spacer Color,OA Glass 108. Thickness= 1"OA(6mm/.50"/6mm), NFRC Unit Glass Strength=Tempered Unit 1:Tempered Glass, 1"OA(6mm/.50"/6mm) HARDWARE OPTIONS Coastal Stainless Package Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Applied Special Order Notes: need to know if any steel should be between units D and E as indicated on the attached elevation"Unit D+E".will also need u values for each unit STRUCTURE BY OTHERS REQUIRED BETWEEN 6-1 AND 7-1 Warnings: The glass on this unit is over 40 square feet and must be tempered. Line Notes: Weight(Ibs): 301.4772 Line Item Quantity Net Price Extended Price 5-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Living Room (E) Special PRODUCT TYPE Series 7630 Direct Set 108 x 144 Frame Width=54, Frame Height= 144 Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No COLOR OPTIONS • Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1,2: Glass Provider=Cardinal,Glazing Type= Insulated Low E Triple Pane,Cardinal 366,Cardinal i89 on Surface 6=No,Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer,Black Spacer Color,OA Glass Thickness=1.6"OA (5mm/.51"/Smm/.51"/5mm),NFRC Unit Glass Strength=Tempered Unit 1,2:Tempered Glass, Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm) HARDWARE OPTIONS ,oa Coastal Stainless Package NFRC U-Factor=0.22, U-Factor-Metric= 1.25,SHGC=0.22, CR=74,VT=0.49,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-41-00008-00022, ENERGY STAR: Northern=Yes, ENERGY STAR: North-Central=Yes, ENERGY STAR:South-Central=Yes, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Shipped Loose, Drip Cap Cut Length=108 Wrapping-Mull Options Mull Method=Verticals Run Thru RECEIVED printed by Carlie Urell Page/5 of 2 619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered windOW S stems CtI Quote Name: @lSkrOdstomView-Quote Ship Date: PO Number: �� y westernwi n dowsystems.com Ship Via: Bid by: Special Order Notes: need to know if you can make this piece of glass,and if structure is needed between this unit and the previous living room (D)to match picture attached"Unit D+E"also will need u-value STRUCTURE BY OTHERS REQUIRED BETWEEN 6-1 AND 7-1,VERTICAL MULL ADDED DUE TO GLASS SIZE. Warnings: The glass on this unit is over 40 square feet and must be tempered. Line Notes: Weight(Ibs): 871.012 Line Item Quantity Net Price Extended Price 6-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Living Room (D)stand alone unit Special PRODUCT TYPE Series 7630 Direct Set Trapezoid 108 x 58.03125 Frame Width= 108, Frame Height=58.03125, Frame Short Side=22.03125 I Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No,Trapezoid Head Length=115.342,Trapezoid Head Angle= 18.435, Facing Dimension=Left COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS r Unit 1:Glass Provider=Cardinal,Glazing Type=Insulated Low E Triple Pane, Cardinal 366,Cardinal i89 on . Surface 6=No, Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT= No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm), NFRC Unit Glass Strength=Tempered Unit 1:Tempered Glass,Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm) HARDWARE OPTIONS Coastal Stainless Package NFRC U-Factor=0.22, U-Factor-Metric= 1.25,SHGC=0.22, CR=74,VT=0.49,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-41-00008-00022, ENERGY STAR: Northern=Yes, ENERGY STAR: North-Central=Yes, ENERGY STAR:South-Central=Yes, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Applied Special Order Notes: this unit is a stand alone trap and just need to approve and get u-value TRAP IS APPROVED Warnings: The glass on this unit is over 40 square feet and must be tempered. Line Notes: Weight(Ibs): 359.9686 RECEIVED printed by Carlie Urell Page/6 of 2 619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered windOW S stems Quote Name: @otfyIS OCIstomView-Quote Ship Date: y westernwi n dowsystems.com PO Number: Ship Via: Bid by: Line Item Quantity Net Price Extended Price 7-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Living Room (G) Special PRODUCT TYPE Series 7630 Direct Set 220.75 x 58.03125 Frame Width= 110.375, Frame Height=58.03125 Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No COLOR OPTIONS • Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1,2: Glass Provider=Cardinal,Glazing Type= Insulated Low E Triple Pane,Cardinal 366,Cardinal i89 on Surface 6=No,Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer,Black Spacer Color,OA Glass Thickness=1.6"OA (5mm/.51"/5mm/.51"/5mm),NFRC Unit Glass Strength=Tempered Unit 1,2:Tempered Glass, Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm) HARDWARE OPTIONS Coastal Stainless Package NFRC U-Factor=0.22, U-Factor-Metric= 1.25,SHGC=0.22, CR=74,VT=0.49,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-41-00008-00022, ENERGY STAR: Northern=Yes, ENERGY STAR: North-Central=Yes, ENERGY STAR:South-Central=Yes, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Shipped Loose, Drip Cap Cut Length=220.75 Wrapping-Mull Options Mull Method=Verticals Run Thru Special Order Notes: architect wants to place this unit 1 foot above a sliding glass door(Living Room I)and wondering if additional structure is needed above header.also need U-values for this unit STRUCTURE BY OTHERS REQUIRED BETWEEN 9-1 AND 10-1 Warnings: The glass on this unit is over 40 square feet and must be tempered. Line Notes: Weight(Ibs): 729.8547 RECEIVED printed by Carlie Urell Page/10/2619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered WindOW s stems Quote Name: @ottylS a4astomView-Quote Ship Date: PO Number: �� y westernwindowsystems.com Ship Via: Bid by: Line Item Quantity Net Price Extended Price 8-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Living Room (I) PRODUCT TYPE Series 7650 Quad Sliding Door OXXO 220.75 x 144 Frame Width=220.75, Frame Height= 144 Complete Unit, Flush Sill, Include Install Holes in Sill, Include Jamb Filler?=Yes,Compensation Channel?= No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1:Glass Provider=Cardinal,Glazing Type=Insulated Low E Triple Pane, Cardinal 366,Cardinal i89 on Surface 6=No, Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT= No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm), NFRC Unit Glass Strength=Tempered Unit 1 Left, 1 Left Center, 1 Right Center, 1 Right:Tempered Glass,Glass Thickness= 1.6"OA (5mm/.51"/5mm/.51"/5mm) HARDWARE OPTIONS Coastal Stainless Package, Handle Type=New Flush Handle, Black Hardware, Roller Type=Quad Rollers SCREEN INFORMATION Screen(s),Black Fiberglass Mesh,Screens Bundled Separately NFRC U-Factor=0.24, U-Factor-Metric= 1.36,SHGC=0.2,CR=63,VT=0.43,AL=0.3,AL-Metric= 1.52,CPD= WIG-A-37-00042-00019, ENERGY STAR: Northern=Yes,ENERGY STAR:North-Central=Yes, ENERGY STAR:South-Central=Yes, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=No Special Order Notes: Warnings: Due to argon gas leakage, NFRCs will display as if Air was selected when combining Capillary Tubes with Argon Gas. Line Notes: Weight(Ibs): 1797.587 Line Item Quantity Net Price Extended Price 9-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Living Room (J) Special PRODUCT TYPE Series 7950 Multi Bi Fold Door 3L 108 x 144 Frame Width= 108, Frame Height= 144 3 Panels,Complete Unit,Swing Out Direction, Flush Sill, Shipped,and not crated by Western Window Systems COLOR OPTIONS Split Finish=No, Bronze Anodized $ GLASS OPTIONS Unit 1:Glass Provider=Cardinal,Glazing Type=Insulated Low E Triple Pane, Cardinal 366,Cardinal i89 on Surface 6=No, Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT= No,Stainless Steel Spacer, Black Spacer Color, NFRC Unit Glass Strength=Tempered Unit 1 1, 1 2, 1 3:Tempered Glass,Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm) HARDWARE OPTIONS Coastal Stainless Package, Heavy Duty Head Load, Black Hardware NFRC U-Factor=0.24, U-Factor-Metric= 1.36,SHGC=0.17, CR=59,VT=0.37, CPD=WIG-A-39-00142-00022 Wrapping-Perimeter Options Perimeter Frame=Equal Leg RECEIVED printed by Carlie Urell Page/80of 2619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered Window s stems Quote Name: @Clrg9astomView-Quote Ship Date: PO Number: �� y westernwindowsystems.com Ship Via: Bid by: Special Order Notes: wondering if you can make this folding door and if not is there another option to choose to meet architect design? DOOR IS APPROVED WITH HEAVY DUTY HEAD LOAD HARDWARE Warnings: This sill system provides NO protection from water intrusion and should only be used in well protected conditions Line Notes: Weight(Ibs): 880.4788 Line Item Quantity Net Price Extended Price 10-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Dining Room (J) Special PRODUCT TYPE Series 7950 Multi Bi Fold Door 3R 108 x 144 Frame Width= 108, Frame Height= 144 3 Panels,Complete Unit,Swing Out Direction, Flush Sill, Shipped,and not crated by Western Window Systems COLOR OPTIONS Split Finish=No, Bronze Anodized $ GLASS OPTIONS Unit 1:Glass Provider=Cardinal,Glazing Type=Insulated Low E Triple Pane, Cardinal 366,Cardinal i89 on Surface 6=No, Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT= No,Stainless Steel Spacer, Black Spacer Color, NFRC Unit Glass Strength=Tempered Unit 1 1, 1 2, 1 3:Tempered Glass,Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm) HARDWARE OPTIONS Coastal Stainless Package, Heavy Duty Head Load, Black Hardware NFRC U-Factor=0.24, U-Factor-Metric= 1.36,SHGC=0.17, CR=59,VT=0.37, CPD=WIG-A-39-00142-00022 Wrapping-Perimeter Options Perimeter Frame=Equal Leg Special Order Notes: wondering if you can make this configuration and also need u-value DOOR IS APPROVED WITH HEAVY DUTY HEAD LOAD HARDWARE Warnings: This sill system provides NO protection from water intrusion and should only be used in well protected conditions Line Notes: Weight(Ibs): 880.4788 RECEIVED printed by Carlie Urell Page/90of 2619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered windOW S stems Quote Name: @otfyIS OCIstomView-Quote Ship Date: PO Number: �� y westernwi n dowsystems.com Ship Via: Bid by: Line Item Quantity Net Price Extended Price 11-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Kitchen (K)-make sure bottom right is Special PRODUCT TYPE Row 1:Series 7630 Direct Set 48 x 29.34375 Row 2:Series 7630 Direct Set 48 x 29.34375 Row 3:Series 7630 Direct Set 48 x 68.09325 Row 4:Series 7630 Direct Set 144 x 41.71875 Unit 1,2: Frame Width=48, Frame Height=29.34375 Unit 3: Frame Width=48, Frame Height=68.09325 Unit 4: Frame Width= 144, Frame Height=41.71875 Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No COLOR OPTIONS Split Finish=No, Bronze Anodized '" GLASS OPTIONS Unit 1,2,3,4:Glass Provider=Cardinal,Glazing Type= Insulated Low E Triple Pane,Cardinal 366, Cardinal i89 on Surface 6=No,Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1.6"OA (5mm/.51"/5mm/.51"/5mm),NFRC Unit Glass Strength=Tempered Unit 1,2,3,4:Tempered Glass,Glass Thickness= 1.6"OA(5mm/.51"/Smm/.51"/5mm) HARDWARE OPTIONS Coastal Stainless Package NFRC U-Factor=0.22, U-Factor-Metric= 1.25,SHGC=0.22, CR=74,VT=0.49,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-41-00008-00022, ENERGY STAR: Northern=Yes, ENERGY STAR: North-Central=Yes, ENERGY STAR:South-Central=Yes, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Shipped Loose, Drip Cap Cut Length=192 Wrapping-Mull Options Mull Method=Verticals Run Thru Special Order Notes: need U-value for this unit please WINDOW IS APPROVED, Warnings: The tops of Window 4 and Window 3 are not quite aligned.Verify their dimensions. Line Notes: Weight(Ibs): 698.7554 RECEIVED 0/2 printed by Carlie Urell Page/10 of 2619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered WIIIdOW S stems Quote Name: @otty F OCIstomView-Quote Ship Date: PO Number: �� y westernwindowsystems.com Ship Via: Bid by: Line Item Quantity Net Price Extended Price 12-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Living Room (F) PRODUCT TYPE Series 7630 Direct Set 48 x 58.03125 Frame Width=48, Frame Height=58.03125 Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1:Glass Provider=Cardinal,Glazing Type=Insulated Low E Triple Pane, Cardinal 366,Cardinal i89 on Surface 6=No, Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT= No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm), NFRC Unit Glass Strength=Tempered Unit 1:Tempered Glass,Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm) HARDWARE OPTIONS 48• Coastal Stainless Package NFRC U-Factor=0.22, U-Factor-Metric= 1.25,SHGC=0.22, CR=74,VT=0.49,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-41-00008-00022, ENERGY STAR: Northern=Yes, ENERGY STAR: North-Central=Yes, ENERGY STAR:South-Central=Yes, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Applied Special Order Notes: Warnings: Due to argon gas leakage, NFRCs will display as if Air was selected when combining Capillary Tubes with Argon Gas. Line Notes: Weight(Ibs): 165.3902 Line Item Quantity Net Price Extended Price 13-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Living Room (F) PRODUCT TYPE Series 7630 Direct Set 48 x 58.03125 Frame Width=48, Frame Height=58.03125 Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1:Glass Provider=Cardinal,Glazing Type=Insulated Low E Triple Pane, Cardinal 366,Cardinal i89 on Surface 6=No, Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT= No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm), NFRC Unit Glass Strength=Tempered Unit 1:Tempered Glass,Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm) HARDWARE OPTIONS Coastal Stainless Package NFRC U-Factor=0.22, U-Factor-Metric= 1.25,SHGC=0.22, CR=74,VT=0.49,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-41-00008-00022, ENERGY STAR: Northern=Yes, ENERGY STAR: North-Central=Yes, ENERGY STAR:South-Central=Yes, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Applied Special Order Notes: Warnings: Due to argon gas leakage, NFRCs will display as if Air was selected when combining Capillary Tubes with Argon Gas. Line Notes: Weight(Ibs): 165.3902 RECEIVED printed by Carlie Urell Page/1 Hof 22619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered windOW S stems Quote Name: @otfyIS OCIstomView-Quote Ship Date: y westernwi n dowsystems.com PO Number: Ship Via: Bid by: Line Item Quantity Net Price Extended Price 14-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Living Room (H) Special PRODUCT TYPE Row 1:Series 7675 Direct Set 48 x 26.375 } Row 2:Series 7660 Awning Top 48 x 26.375 Row 3:Series 7675 Direct Set 48 x 26.375 Row 4:Series 7675 Direct Set 48 x 26.375 } Row 5:Series 7675 Direct Set 48 x 26.375 • Frame Width=48, Frame Height=26.375 w Unit 1,3,4,5:Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No, } Shipped,and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No Unit 2:Complete Unit,Operation/Venting=Top,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS —� — Unit 1,2: Glass Provider=Cardinal, Insulated Low E,Cardinal 366,Cardinal i89?=Yes, Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1"OA(6mm/.50"/6mm), NFRC Unit Glass Strength=Tempered Unit 1,2:Tempered Glass, 1"OA(6mm/.50"/6mm) Unit 3,4, 5:Glass Provider=Cardinal, Insulated Low E,Cardinal 366,Cardinal i89?=Yes, Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1"OA(6mm/.50"/6mm), NFRC Unit Glass Strength=Annealed Unit 3,4, 5:Annealed Glass, 1"OA(6mm/.50"/6mm) HARDWARE OPTIONS Operator Type=Awning Operator, Hardware Color matches Frame SCREEN INFORMATION Screen(s),Black Fiberglass Mesh,Screens Bundled Separately NFRC Unit 1,3,4,5: U-Factor=0.28,U-Factor-Metric= 1.59,SHGC=0.23,CR=48,VT=0.52,AL=0.3, AL-Metric= 1.52,CPD=WIG-A-45-00089-00022,ENERGY STAR:North-Central=Yes, ENERGY STAR: South-Central=Yes, ENERGY STAR:Southern=Yes Unit 2: U-Factor=0.36, U-Factor-Metric=2.04,SHGC=0.19,CR=45,VT=0.41,AL=0.3,AL-Metric= 1.52, CPD=WIG-A-43-00079-00022, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Shipped Loose, Drip Cap Cut Length=48 Wrapping-Mull Options Mull Method=Verticals Run Thru Special Order Notes: is it possible to have the awning unit be the 2nd from bottom instead of the bottom as shown in attachement"Living Room(H)"I will also need U values WINDOW IS APPROVED Warnings: Max Glass Width is 42 for Tempered, 1"OA(6mm/.50"/6mm)on Series 7675 Rectangle units. Line Notes: Weight(Ibs): 340.333 RECEIVED 0/2 printed by Carlie Urell Page/12 of 2619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered windOW S stems Quote Name: @otfyIS OCIstomView-Quote Ship Date: y westernwi n dowsystems.com PO Number: Ship Via: Bid by: Line Item Quantity Net Price Extended Price 15-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Living Room (H) Special PRODUCT TYPE Row 1:Series 7675 Direct Set 48 x 26.375 } Row 2:Series 7660 Awning Top 48 x 26.375 Row 3:Series 7675 Direct Set 48 x 26.375 Row 4:Series 7675 Direct Set 48 x 26.375 } Row 5:Series 7675 Direct Set 48 x 26.375 • Frame Width=48, Frame Height=26.375 w Unit 1,3,4,5:Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No, } Shipped,and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No Unit 2:Complete Unit,Operation/Venting=Top,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS —� — Unit 1,2: Glass Provider=Cardinal, Insulated Low E,Cardinal 366,Cardinal i89?=Yes, Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1"OA(6mm/.50"/6mm), NFRC Unit Glass Strength=Tempered Unit 1,2:Tempered Glass, 1"OA(6mm/.50"/6mm) Unit 3,4, 5:Glass Provider=Cardinal, Insulated Low E,Cardinal 366,Cardinal i89?=Yes, Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1"OA(6mm/.50"/6mm), NFRC Unit Glass Strength=Annealed Unit 3,4, 5:Annealed Glass, 1"OA(6mm/.50"/6mm) HARDWARE OPTIONS Operator Type=Awning Operator, Hardware Color matches Frame SCREEN INFORMATION Screen(s),Black Fiberglass Mesh,Screens Bundled Separately NFRC Unit 1,3,4,5: U-Factor=0.28,U-Factor-Metric= 1.59,SHGC=0.23,CR=48,VT=0.52,AL=0.3, AL-Metric= 1.52,CPD=WIG-A-45-00089-00022,ENERGY STAR:North-Central=Yes, ENERGY STAR: South-Central=Yes, ENERGY STAR:Southern=Yes Unit 2: U-Factor=0.36, U-Factor-Metric=2.04,SHGC=0.19,CR=45,VT=0.41,AL=0.3,AL-Metric= 1.52, CPD=WIG-A-43-00079-00022, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Shipped Loose, Drip Cap Cut Length=48 Wrapping-Mull Options Mull Method=Verticals Run Thru Special Order Notes: is it possible to have the awning unit be the 2nd from bottom instead of the bottom as shown in attachement"Living Room(H)"I will also need U values WINDOW IS APPROVED Warnings: Max Glass Width is 42 for Tempered, 1"OA(6mm/.50"/6mm)on Series 7675 Rectangle units. Line Notes: Weight(Ibs): 340.333 RECEIVED 0/2 printed by Carlie Urell Page/13 of 2619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered windOW S stems Quote Name: @otfyIS OCIstomView-Quote Ship Date: y westernwi n dowsystems.com PO Number: Ship Via: Bid by: Line Item Quantity Net Price Extended Price 16-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Dining Room (H) Special PRODUCT TYPE Row 1:Series 7675 Direct Set 48 x 26.375 } Row 2:Series 7660 Awning Top 48 x 26.375 Row 3:Series 7675 Direct Set 48 x 26.375 Row 4:Series 7675 Direct Set 48 x 26.375 } Row 5:Series 7675 Direct Set 48 x 26.375 • Frame Width=48, Frame Height=26.375 w Unit 1,3,4,5:Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No, } Shipped,and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No Unit 2:Complete Unit,Operation/Venting=Top,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS —� — Unit 1,2: Glass Provider=Cardinal, Insulated Low E,Cardinal 366,Cardinal i89?=Yes, Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1"OA(6mm/.50"/6mm), NFRC Unit Glass Strength=Tempered Unit 1,2:Tempered Glass, 1"OA(6mm/.50"/6mm) Unit 3,4, 5:Glass Provider=Cardinal, Insulated Low E,Cardinal 366,Cardinal i89?=Yes, Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1"OA(6mm/.50"/6mm), NFRC Unit Glass Strength=Annealed Unit 3,4, 5:Annealed Glass, 1"OA(6mm/.50"/6mm) HARDWARE OPTIONS Operator Type=Awning Operator, Hardware Color matches Frame SCREEN INFORMATION Screen(s),Black Fiberglass Mesh,Screens Bundled Separately NFRC Unit 1,3,4,5: U-Factor=0.28,U-Factor-Metric= 1.59,SHGC=0.23,CR=48,VT=0.52,AL=0.3, AL-Metric= 1.52,CPD=WIG-A-45-00089-00022,ENERGY STAR:North-Central=Yes, ENERGY STAR: South-Central=Yes, ENERGY STAR:Southern=Yes Unit 2: U-Factor=0.36, U-Factor-Metric=2.04,SHGC=0.19,CR=45,VT=0.41,AL=0.3,AL-Metric= 1.52, CPD=WIG-A-43-00079-00022, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Shipped Loose, Drip Cap Cut Length=48 Wrapping-Mull Options Mull Method=Verticals Run Thru Special Order Notes: is it possible to have the awning unit be the 2nd from bottom instead of the bottom as shown in attachement"Living Room(H)"I will also need U values WINDOW IS APPROVED Warnings: Max Glass Width is 42 for Tempered, 1"OA(6mm/.50"/6mm)on Series 7675 Rectangle units. Line Notes: Weight(Ibs): 340.333 RECEIVED 0/2 printed by Carlie Urell Page/14 of 2619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered windOW S stems Quote Name: @otfyIS OCIstomView-Quote Ship Date: y westernwi n dowsystems.com PO Number: Ship Via: Bid by: Line Item Quantity Net Price Extended Price 17-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Living Room (J)Alternate PRODUCT TYPE Series 7650 Double Sliding Door XO 108 x 144 Frame Width= 108, Frame Height= 144 Complete Unit, Flush Sill, Include Install Holes in Sill, Include Jamb Filler?=Yes,Compensation Channel?= No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1:Glass Provider=Cardinal,Glazing Type=Insulated Low E Triple Pane, Cardinal 366,Cardinal i89 on Surface 6=No, Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT= No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm), NFRC Unit Glass Strength=Tempered Unit 1 Left, 1 Right:Tempered Glass,Glass Thickness= 1.6"OA(5mm/.51"!Smm/.51"/5mm) HARDWARE OPTIONS Coastal Stainless Package, Handle Type=New Flush Handle, Black Hardware, Roller Type=Quad Rollers SCREEN INFORMATION Screen(s),Black Fiberglass Mesh,Screens Bundled Separately NFRC U-Factor=0.24, U-Factor-Metric= 1.36,SHGC=0.2,CR=63,VT=0.43,AL=0.3,AL-Metric= 1.52,CPD= WIG-A-37-00042-00019, ENERGY STAR: Northern=Yes,ENERGY STAR:North-Central=Yes, ENERGY STAR:South-Central=Yes, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=No Special Order Notes: Warnings: Due to argon gas leakage, NFRCs will display as if Air was selected when combining Capillary Tubes with Argon Gas. Line Notes: Weight(Ibs): 893.5951 Line Item Quantity Net Price Extended Price 18-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Dining Room (J)Alternate PRODUCT TYPE Series 7650 Double Sliding Door XO 108 x 144 Frame Width= 108, Frame Height= 144 Complete Unit, Flush Sill, Include Install Holes in Sill, Include Jamb Filler?=Yes,Compensation Channel?= No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1:Glass Provider=Cardinal,Glazing Type=Insulated Low E Triple Pane, Cardinal 270,Cardinal i89 on Surface 6=Yes,Cardinal 180 on Surface 4=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT =No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1.6"OA (5mm/.51"/Smm/.51"/5mm),NFRC Unit Glass Strength=Tempered Unit 1 Left, 1 Right:Tempered Glass,Glass Thickness= 1.6"OA(5mm/.51"!Smm/.51"/5mm) HARDWARE OPTIONS oa Coastal Stainless Package, Handle Type=New Flush Handle, Black Hardware, Roller Type=Quad Rollers SCREEN INFORMATION Screen(s),Black Fiberglass Mesh,Screens Bundled Separately NFRC U-Factor=0.22, U-Factor-Metric= 1.25,SHGC=0.24, CR=55,VT=0.45,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-37-00046-00016, ENERGY STAR: Northern=Yes, ENERGY STAR: North-Central=Yes, ENERGY STAR:South-Central=Yes, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=No RECEIVED 0/2 printed by Carlie Urell Page/15 of 2619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered Window s stems Quote Name: @C I skrecistomView-Quote Ship Date: PO Number: �� y westernwindowsystems.com Ship Via: Bid by: Special Order Notes: Warnings: Due to argon gas leakage, NFRCs will display as if Air was selected when combining Capillary Tubes with Argon Gas. Line Notes: Weight(Ibs): 893.5951 Line Item Quantity Net Price Extended Price 19-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Entry(L) PRODUCT TYPE Row 1:Series 7630 Direct Set 82.125 x 26.375 Row 2:Series 7630 Direct Set 82.125 x 85.125 Unit 1: Frame Width=82.125, Frame Height=26.375 Unit 2: Frame Width=82.125, Frame Height=85.125 Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1,2: Glass Provider=Cardinal,Glazing Type= Insulated Low E Triple Pane,Cardinal 366,Cardinal i89 on Surface 6=No,Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer,Black Spacer Color,OA Glass Thickness=1.6"OA I le (5mm/.51"I5mm/.51"/5mm),NFRC Unit Glass Strength=Tempered 62,25" Unit 1,2:Tempered Glass, Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"I5mm) HARDWARE OPTIONS Coastal Stainless Package NFRC U-Factor=0.22, U-Factor-Metric= 1.25,SHGC=0.22, CR=74,VT=0.49,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-41-00008-00022, ENERGY STAR: Northern=Yes, ENERGY STAR: North-Central=Yes, ENERGY STAR:South-Central=Yes, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Shipped Loose, Drip Cap Cut Length=93 Wrapping-Mull Options Mull Method=Verticals Run Thru Special Order Notes: Warnings: The glass on this unit is over 40 square feet and must be tempered. Line Notes: Weight(Ibs): 503.2939 RECEIVED printed by Carlie Urell Page/160 of 22619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered WIIIdOW S stems CtI Quote Name: @lSkrOdstomView-Quote Ship Date: y westernwindowsystems.com PO Number: Ship Via: Bid by: Line Item Quantity Net Price Extended Price 20-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Bedroom#2 (L) Special PRODUCT TYPE Series 7670 Casement Left 42 x 58.75 Frame Width=42, Frame Height=58.75 Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1:Glass Provider=Cardinal, Insulated Low E,Cardinal 366,Cardinal i89?=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1"OA(6mm/.50"/6mm), NFRC Unit Glass Strength=Tempered Unit 1:Tempered Glass, 1"OA(6mm/.50"/6mm) , HARDWARE OPTIONS Operator Type=Encore Operator, Hardware Color matches Frame,Lock Type=Standard Multi Point 4r SCREEN INFORMATION Screen(s),Black Fiberglass Mesh,Screens Bundled Separately GRILLES Simulated Divided Lite 1.50", Prairie,T NFRC U-Factor=0.35, U-Factor-Metric= 1.99,SHGC=0.16, CR=46,VT=0.33,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-42-00079-00024, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Applied Special Order Notes: architect wants SDL bar directly in center of unit and wants the SDL bar as thick as the mulls in the adjacent frame.please advise. see attached picture"Casement L"for reference QUOTING 1.50"MAXIMUM SIZE GRID Warnings: Due to argon gas leakage, NFRCs will display as if Air was selected when combining Capillary Tubes with Argon Gas. Line Notes: Weight(Ibs): 133.2201 Line Item Quantity Net Price Extended Price 21-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Bathroom#2 (L) Special PRODUCT TYPE Series 7670 Casement Left 42 x 58.75 Frame Width=42, Frame Height=58.75 Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1:Glass Provider=Cardinal, Insulated Low E,Cardinal 366,Cardinal i89?=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1"OA(6mm/.50"/6mm), NFRC Unit Glass Strength=Tempered Unit 1:Tempered Glass, 1"OA(6mm/.50"/6mm) HARDWARE OPTIONS Operator Type=Encore Operator, Hardware Color matches Frame,Lock Type=Standard Multi Point 47 SCREEN INFORMATION Screen(s),Black Fiberglass Mesh,Screens Bundled Separately GRILLES Simulated Divided Lite 1.50", Prairie,T NFRC U-Factor=0.35, U-Factor-Metric= 1.99,SHGC=0.16, CR=46,VT=0.33,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-42-00079-00024, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options cRErEfVE� Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Applie printed by Carlie Urell Page/1170 of 22619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered WIIIdOW S stems CtI Quote Name: @lSkrOdstomView-Quote Ship Date: PO Number: �� y westernwindowsystems.com Ship Via: Bid by: Special Order Notes: architect wants SDL bar directly in center of unit and wants the SDL bar as thick as the mulls in the adjacent frame.please advise. see attached picture"Casement L"for reference QUOTING 1.50"MAXIMUM SIZE GRID Warnings: Due to argon gas leakage, NFRCs will display as if Air was selected when combining Capillary Tubes with Argon Gas. Line Notes: Weight(Ibs): 133.2201 Line Item Quantity Net Price Extended Price 22-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Garage (L) Special PRODUCT TYPE Series 7670 Casement Left 42 x 58.75 Frame Width=42, Frame Height=58.75 Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1:Glass Provider=Cardinal, Insulated Low E,Cardinal 366,Cardinal i89?=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1"OA(6mm/.50"/6mm), NFRC Unit Glass Strength=Tempered Unit 1:Tempered Glass, 1"OA(6mm/.50"/6mm) HARDWARE OPTIONS Operator Type=Encore Operator, Hardware Color matches Frame,Lock Type=Standard Multi Point 42- SCREEN INFORMATION Screen(s),Black Fiberglass Mesh,Screens Bundled Separately GRILLES Simulated Divided Lite 1.50", Prairie,T NFRC U-Factor=0.35, U-Factor-Metric= 1.99,SHGC=0.16, CR=46,VT=0.33,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-42-00079-00024, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Applied Special Order Notes: architect wants SDL bar directly in center of unit and wants the SDL bar as thick as the mulls in the adjacent frame.please advise. see attached picture"Casement L"for reference QUOTING 1.50"MAXIMUM SIZE GRID Warnings: Due to argon gas leakage, NFRCs will display as if Air was selected when combining Capillary Tubes with Argon Gas. Line Notes: Weight(Ibs): 133.2201 RECEIVED printed by Carlie Urell Page/180 of 22619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered WindOW s stems Quote Name: @C I skrecistomView-Quote Ship Date: PO Number: �� y westernwindowsystems.com Ship Via: Bid by: Line Item Quantity Net Price Extended Price 23-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Bedroom#2 (N) PRODUCT TYPE Series 7630 Direct Set 76 x 30.375 Frame Width=76, Frame Height=30.375 Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not — crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1:Glass Provider=Cardinal,Glazing Type=Insulated Low E Triple Pane, Cardinal 366,Cardinal i89 on Surface 6=No, Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT= No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1.6"OA(5mm/.51"15mm/.51"/5mm), NFRC Unit Glass Strength=Tempered Unit 1:Tempered Glass,Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm) HARDWARE OPTIONS Coastal Stainless Package NFRC U-Factor=0.22, U-Factor-Metric= 1.25,SHGC=0.22, CR=74,VT=0.49,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-41-00008-00022, ENERGY STAR: Northern=Yes, ENERGY STAR: North-Central=Yes, ENERGY STAR:South-Central=Yes, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Applied Special Order Notes: Warnings: Due to argon gas leakage, NFRCs will display as if Air was selected when combining Capillary Tubes with Argon Gas. Line Notes: Weight(Ibs): 142.2126 RECEIVED printed by Carlie Urell Page/190 of 22619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered windOW S stems Quote Name: @otfyIS OCIstomView-Quote Ship Date: y westernwi n dowsystems.com PO Number: Ship Via: Bid by: Line Item Quantity Net Price Extended Price 24-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Master Bedroom (0) Special PRODUCT TYPE Row 1:Series 7660 Awning Top 43 x 30.375 Row 2:Series 7675 Direct Set 89 x 58.75 Row 3:Series 7675 Direct Set 43 x 28.375 Unit 1: Frame Width=43, Frame Height=30.375 Unit 2: Frame Width=89, Frame Height=58.75 Unit 3: Frame Width=43, Frame Height=28.375 Unit 1:Complete Unit,Operation/Venting=Top,Standard Sill,Compensation Channel?=No, Performance / \ Sill Pan?=No,Shipped,and not crated by Western Window Systems I Unit 2,3: Complete Unit,Standard Sill,Compensation Channel?=No,Performance Sill Pan?=No,Shipped, 43. and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1,2,3:Glass Provider=Cardinal, Insulated Low E,Cardinal 366,Cardinal i89?=Yes, Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1"OA(6mm/.50"/6mm), NFRC Unit Glass Strength=Tempered Unit 1,2,3:Tempered Glass, 1"OA(6mm/.50"/6mm) HARDWARE OPTIONS Operator Type=Awning Operator, Hardware Color matches Frame, Lock Type=Standard Multi Point SCREEN INFORMATION Screen(s),Black Fiberglass Mesh,Screens Bundled Separately NFRC Unit 1: U-Factor=0.36, U-Factor-Metric=2.04,SHGC=0.19,CR=45,VT=0.41,AL=0.3,AL-Metric= 1.52, CPD=WIG-A-43-00079-00022, ENERGY STAR:Southern=Yes Unit 2,3: U-Factor=0.28, U-Factor-Metric= 1.59,SHGC=0.23,CR=48,VT=0.52,AL=0.3,AL-Metric= 1.52, CPD=WIG-A-45-00089-00022, ENERGY STAR: North-Central=Yes, ENERGY STAR:South- Central=Yes, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Shipped Loose, Drip Cap Cut Length=132 Wrapping-Mull Options Mull Method=Verticals Run Thru Special Order Notes: can you please advise if unit on right can be greater than 60 per architect drawing attached"Master Bedroom 0" WINDOW IS APPROVED Warnings: Max Glass Width is 42 for Tempered, 1"OA(6mm/.50"/6mm)on Series 7675 Rectangle units. Line Notes: Weight(Ibs): 460.4445 RECEIVED printed by Carlie Urell Page/20 of 2019 6 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered WIIIdOW S stems CtI Quote Name: @lSkrOdstomView-Quote Ship Date: PO Number: �� y westernwindowsystems.com Ship Via: Bid by: Line Item Quantity Net Price Extended Price 25-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Master Bedroom (P) PRODUCT TYPE _ Series 7650 Double Sliding Door XO 132 x 108 Frame Width= 132, Frame Height= 108 Complete Unit, Flush Sill, Include Install Holes in Sill, Include Jamb Filler?=Yes,Compensation Channel?= No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems COLOR OPTIONS Split Finish=No, Bronze Anodized $ GLASS OPTIONS Unit 1:Glass Provider=Cardinal,Glazing Type=Insulated Low E Triple Pane, Cardinal 366,Cardinal i89 on Surface 6=No, Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT= No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm), NFRC Unit Glass Strength=Tempered Unit 1 Left, 1 Right:Tempered Glass,Glass Thickness= 1.6"OA(5mm/.51"!Smm/.51"/5mm) HARDWARE OPTIONS Coastal Stainless Package, Handle Type=New Flush Handle, Black Hardware, Roller Type=Quad Rollers SCREEN INFORMATION Screen(s),Black Fiberglass Mesh,Screens Bundled Separately NFRC U-Factor=0.24, U-Factor-Metric= 1.36,SHGC=0.2,CR=63,VT=0.43,AL=0.3,AL-Metric= 1.52,CPD= WIG-A-37-00042-00019, ENERGY STAR: Northern=Yes,ENERGY STAR:North-Central=Yes, ENERGY STAR:South-Central=Yes, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=No Special Order Notes: Warnings: Due to argon gas leakage, NFRCs will display as if Air was selected when combining Capillary Tubes with Argon Gas. Line Notes: Weight(Ibs): 815.6439 Line Item Quantity Net Price Extended Price 26-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Master Bathroom (Q) PRODUCT TYPE Row 1:Series 7630 Direct Set 43 x 28.375 Row 2:Series 7630 Direct Set 43 x 28.375 Row 3:Series 7630 Direct Set 43 x 28.375 Frame Width=43, Frame Height=28.375 Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No COLOR OPTIONS Split Finish=No, Bronze Anodized f GLASS OPTIONS Unit 1,2,3:Glass Provider=Cardinal,Glazing Type= Insulated Low E Triple Pane,Cardinal 366,Cardinal i89 on Surface 6=No,Cardinal 180 on Surface 5=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer,Black Spacer Color,OA Glass Thickness=1.6"OA I - (5mm/.51"/Smm/.51"/5mm),NFRC Unit Glass Strength=Tempered 43• Unit 1,2,3:Tempered Glass,Glass Thickness= 1.6"OA(5mm/.51"/5mm/.51"/5mm) HARDWARE OPTIONS Coastal Stainless Package NFRC U-Factor=0.22, U-Factor-Metric= 1.25,SHGC=0.22, CR=74,VT=0.49,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-41-00008-00022, ENERGY STAR: Northern=Yes, ENERGY STAR: North-Central=Yes, ENERGY STAR:South-Central=Yes, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Shipped Loose, Drip Ca Cut Length=53 RECEIVED Wrapping-Mull Options �� V Mull Method=Verticals Run Thru printed by Carlie Urell Page/210of 2619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered windOW S stems Quote Name: @otfyIS OCIstomView-Quote Ship Date: PO Number: �� y westernwi n dowsystems.com Ship Via: Bid by: Special Order Notes: Warnings: Due to argon gas leakage, NFRCs will display as if Air was selected when combining Capillary Tubes with Argon Gas. Line Notes: Weight(Ibs): 219.673 Line Item Quantity Net Price Extended Price 27-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Master Bedroom (R) Special PRODUCT TYPE Row 1:Series 7630 Direct Set 65 x 87.375 Row 2:Series 7675 Direct Set 43 x 28.375 Row 3:Series 7660 Awning Top 43 x 30.375 Row 4:Series 7675 Direct Set 43 x 28.375 Unit 1: Frame Width=65, Frame Height=87.375 • Unit 2,4: Frame Width=43, Frame Height=28.375 Unit 3: Frame Width=43, Frame Height=30.375 Iz Unit 1,2,4:Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No, • Shipped,and not crated by Western Window Systems,Specific DP,Windspeed,or L/175 Required?=No Unit 3:Complete Unit,Operation/Venting=Top,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems 55 COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1,2,3,4:Glass Provider=Cardinal, Insulated Low E,Cardinal 366,Cardinal i89?=Yes,Gas Filled/ High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1"OA(6mm/.50"I6mm), NFRC Unit Glass Strength=Tempered Unit 1,2,3,4:Tempered Glass, 1"OA(6mm/.50"/6mm) HARDWARE OPTIONS Unit 1:Coastal Stainless Package Unit 3:Operator Type=Awning Operator, Hardware Color matches Frame, Lock Type=Standard Multi Point SCREEN INFORMATION Screen(s),Black Fiberglass Mesh,Screens Bundled Separately NFRC Unit 2,4: U-Factor=0.28, U-Factor-Metric= 1.59,SHGC=0.23,CR=48,VT=0.52,AL=0.3,AL-Metric= 1.52, CPD=WIG-A-45-00089-00022, ENERGY STAR: North-Central=Yes, ENERGY STAR:South- Central=Yes, ENERGY STAR:Southern=Yes Unit 3: U-Factor=0.36, U-Factor-Metric=2.04,SHGC=0.19,CR=45,VT=0.41,AL=0.3,AL-Metric= 1.52, CPD=WIG-A-43-00079-00022, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Shipped Loose, Drip Cap Cut Length=108 Wrapping-Mull Options Mull Method=Verticals Run Thru Special Order Notes: is it possible to change the awning unit from the bottom right to the middle right as drawn in attachement"master bedroom R"? WINDOW IS APPROVED Warnings: Invalid height for Horizontal Mull 1 Line Notes: Weight(Ibs): 495.0639 RECEIVED 11 printed by Carlie Urell age/2 of 2019 6 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered windOW S stems Quote Name: @otfyIS OCIstomView-Quote Ship Date: PO Number: �� y westernwi n dowsystems.com Ship Via: Bid by: Line Item Quantity Net Price Extended Price 28-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Bedroom#3 (S) PRODUCT TYPE Series 7670 Casement Right 34 x 78 Frame Width=34, Frame Height=78 Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1:Glass Provider=Cardinal, Insulated Low E,Cardinal 366,Cardinal i89?=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1"OA(6mm/.50"/6mm), NFRC Unit Glass Strength=Tempered Unit 1:Tempered Glass, 1"OA(6mm/.50"/6mm) HARDWARE OPTIONS Operator Type=Encore Operator, Hardware Color matches Frame,Lock Type=Standard Multi Point SCREEN INFORMATION Screen(s),Black Fiberglass Mesh,Screens Bundled Separately NFRC U-Factor=0.35, U-Factor-Metric= 1.99,SHGC=0.19, CR=46,VT=0.41,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-42-00079-00022, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Applied Special Order Notes: Warnings: Due to argon gas leakage, NFRCs will display as if Air was selected when combining Capillary Tubes with Argon Gas. Line Notes: Weight(Ibs): 142.9388 Line Item Quantity Net Price Extended Price 29-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Bedroom#4 (S) PRODUCT TYPE Series 7670 Casement Right 34 x 78 Frame Width=34, Frame Height=78 Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS i' Unit 1:Glass Provider=Cardinal, Insulated Low E,Cardinal 366,Cardinal i89?=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1"OA(6mm/.50"/6mm), NFRC Unit Glass Strength=Tempered Unit 1:Tempered Glass, 1"OA(6mm/.50"/6mm) HARDWARE OPTIONS Operator Type=Encore Operator, Hardware Color matches Frame,Lock Type=Standard Multi Point SCREEN INFORMATION Screen(s),Black Fiberglass Mesh,Screens Bundled Separately NFRC U-Factor=0.35, U-Factor-Metric= 1.99,SHGC=0.19, CR=46,VT=0.41,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-42-00079-00022, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Applied Special Order Notes: Warnings: Due to argon gas leakage, NFRCs will display as if Air was selected when combining Capillary Tubes with Argon Gas. Line Notes: Weight(Ibs): 142.9388 RECEIVED printed by Carlie Urell Page/23 of 2019 6 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered Window s stems Quote Name: @C �Fg9astomView-Quote Ship Date: PO Number: �� y westernwindowsystems.com Ship Via: Bid by: Line Item Quantity Net Price Extended Price 30-1 1 Outside View(Scaled to Fit) Line Item Description Room ID: Bedroom#5 (S) PRODUCT TYPE Series 7670 Casement Right 34 x 78 Frame Width=34, Frame Height=78 Complete Unit,Standard Sill,Compensation Channel?=No, Performance Sill Pan?=No,Shipped,and not crated by Western Window Systems COLOR OPTIONS Split Finish=No, Bronze Anodized GLASS OPTIONS Unit 1:Glass Provider=Cardinal, Insulated Low E,Cardinal 366,Cardinal i89?=Yes,Gas Filled/High Altitude=w/Capillary Tubes,with NEAT=No,Stainless Steel Spacer, Black Spacer Color,OA Glass Thickness= 1"OA(6mm/.50"/6mm), NFRC Unit Glass Strength=Tempered Unit 1:Tempered Glass, 1"OA(6mm/.50"/6mm) HARDWARE OPTIONS Operator Type=Encore Operator, Hardware Color matches Frame,Lock Type=Standard Multi Point - - SCREEN INFORMATION Screen(s),Black Fiberglass Mesh,Screens Bundled Separately NFRC U-Factor=0.35, U-Factor-Metric= 1.99,SHGC=0.19, CR=46,VT=0.41,AL=0.3,AL-Metric= 1.52,CPD =WIG-A-42-00079-00022, ENERGY STAR:Southern=Yes Wrapping-Perimeter Options Perimeter Frame=Nailing Fin, Drip Cap=Yes, Drip Cap Application Method=Applied Special Order Notes: Warnings: Due to argon gas leakage, NFRCs will display as if Air was selected when combining Capillary Tubes with Argon Gas. Line Notes: Weight(Ibs): 142.9388 RECEIVED printed by Carlie Urell Page/24 of 2 619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered iirr windows stems Quote Name: § �Fa4dstomView-Quote Ship Date: , y PO Number: /, westernwindowsystems.com Ship Via: Bid by: Review Product Information,Terms&Conditions,and Frequently Asked Questions(FAQs)at: www.westernwindowsystems.com/terms-and-conditions and www.westernwindowsystems.com/faq(Custom Orders)and www.westernvolumeprogram.com/terms-and-conditions and www.westernvolumeprogram.com/faq(Volume Program) Quotes&Orders All quotations wit be subject to change unless an order is placed within 60 days from the quotation date and written approval is sent to the Registered Dealer.Further price holds may be available for Volume Program("VP")orders,but must be agreed to in writing by a member of the VP management team. Lead Times&Ship Dates Custom Orders All products are manufactured to your specifications.The lead time wit vary depending upon your requirements and begins when we receive your signed Approval Packet (consisting of a signed Dealer Quotation,any required deposits,and signed shop drawings and color chip,if applicable).Please allow sufficient lead time as advised by your sales representative.At lead times and shipment dates(whether provided in a Quotation,Acknowledgement,or otherwise)are estimates only.Western Window Systems uses commercially reasonable efforts to fill orders in accordance with the estimated lead time and shipment date.However,Western Window Systems will not be responsible for any delays in filling an order nor be liable for any losses or damages resulting from such delays,and no order shall be subject to cancellation for such delays.Please refer to"Lead Times"on the Custom View homepage for current production lead time. Volume Orders VP Program lead times vary by product type and are estimated as follows:7600 Series VP doors=10 production days,600 Series VP doors=10 production days,3600 Series VP doors=5 production days;and Semi-Custom doors=15 production days.(All lead time measurements described herein relate to production days and therefore,do not include time for shipment or delivery).Western Window Systems uses commercially reasonable efforts to fill orders in accordance with the estimated lead time and shipment date. However,Western Window Systems will not be responsible for any delays in filling an order nor be liable for any losses or damages resulting from such delays,and no order shall be subject to cancellation for such delays. Important Notes Western Window Systems is not responsible for determining the suitability of any product for a particular project,design,application,climate,condition,use,or customer need or purpose.Western Window Systems is not responsible for determining whether the incorporation of its products into a building design will achieve a particular third-party certification or standard as windows and doors are only one factor in the building envelope.Determining such product suitability is the responsibility of the architect,contractor,registered dealer,installer,owner,user,and/or other construction professionals.Western Window Systems will also not be responsible for any claims or damage arising from inappropriate selection of products,faulty building design or construction,improper installation,or inaccurate orders. Western Window Systems also does not control the application or selection of its product configurations,sealant,or glazing materials and assumes no responsibility therefore.It is the responsibility of the architect,contractor,registered dealer,installer,owner,user,and/or other construction professionals to make these selections in strict compliance with applicable laws and codes. Registered Dealer is solely responsible for ensuring product shipments are safely received.The Registered Dealer shall provide,or require third-party recipients to provide,at least two(2)individuals to offload products from the truck at the time of delivery.Any failure to provide appropriate personnel may result in the inability to make delivery as scheduled. Western Window Systems will not be responsible for any damages or inconvenience caused by any such delayed shipment and the Registered Dealer shall defend,indemnify,and hold Western Window Systems'harmless from any and all claims,demands,or lawsuits arising from or relating to such delayed shipment. Installation Western Window Systems does not install its products and is therefore not responsible for any installation defects,errors,or omissions.The Registered Dealer is solely responsible to take reasonable steps to ensure WWS'products are installed properly and in strict compliance with American Architectural Manufacturers Association("AAMA")requirements, applicable building codes and regulations,and Western Window Systems'written installation instructions,such as only engaging,hiring,or recommending experienced installation professionals or selling products to building/construction professionals who are responsible for ensuring proper installation. Warranties:exclusive remedy Western Window Systems provides express limited warranties with its Products,which are available at www.westernwindowsystems.com/faq/warranty.Western Window Systems makes no other warranties and expressly disclaims all other representations,warranties,conditions,or covenants of any kind,either statutory,express,or implied including without limitation,any implied warranties of merchantability or fitness for a particular purpose,use,climate,condition,or durability.No distributor,dealer(Registered or otherwise), employee or representative of Western Window Systems has the authority to change,extend,or in any way modify Western Window Systems'express limited warranties,either orally or in writing,and any such modification will have no force or effect. Additional express limited warranties may also be offered by third-party component manufacturers.Contact your Registered Dealer for further details. Estimated Weight (complete units only) Total Weight of All Units NOT including the crate weighted value in lbs(This is an estimated value only): 1605 CEIvED printed by Carlie Urell Page/25 O of 2 619 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT Project Information 303880 western Project Name: 1015 Waters/Hendrickson/ Estimated Quote Not Ordered window s stems Quote Name: § �Fa4dstomView-Quote Ship Date: , y PO Number: /� westernwindowsystems.com Ship Via: Bid by: be a yardstick . of quality some people aren't used to an environment where excellence is expected ► steve jobs Date: Authorized Signature Required The undersigned hereby acknowledges that he/she has read and understands Western Window Systems'Terms and Conditions and will provide a copy of Western Window Systems' Product Information sheet to the property owner. No RECEIVED printed by Carlie Urell Page/26 of 2019 6 printed on 9/26/2019 2:29 PM ASPEN BUILDING DEPARTMENT