Loading...
HomeMy WebLinkAboutChange Order.1015 Waters Ave.0204.2019 (11).ARBK IRRIGATION LEGEND INSTALLATION GENERAL NOTES SLEEVES: CLASS 200 PVC 1. THE SYSTEM DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE FOR THE IRRIGATION SYSTEM OF 60 PSI (MINIMUM REQUIRED), AT A MAXIMUM DISCHARGE OF 10 GPM AT THE 3/4-INCH IRRIGATION POINT-OF-CONNECTION (POC). TAP, MAINLINE PIPE: CLASS 200 PVC METER, BACKFLOW, AND MASTER VALVE SHALL ALL BE THE SAME SIZE. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO Hines Inc 1 1/4-INCH SIZE UNLESS OTHERWISE INDICATED CONSTRUCTION. A-,..._ LATERAL PIPE To SPRINKLERS: CLASS 200 PVC 2. READ THOROUGHLY AND BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED 1-INCH UNLESS OTHERWISE INDICATED WORK PRIOR TO CONSTRUCTION. SITE WATER ENGINEERING SERVICES 323 W.DRAKE RD,SUITE 204 tTh LATERAL PIPE To EMITTERS: UV RADIATION RESISTANT 3. COORDINATE UTILITY LOCATES ("CALL BEFORE YOU DIG") OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. FORT COLLINS,COLORADO 80526 POLYETHYLENE (3/4-INCH SIZE, ROUTING IS DIAGRAMMATIC) Web: 70.282.1800 lb wv,w.inesinc.com 4. DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM WHEN IT IS OBVIOUS IN THE FIELD THAT www.hinesinc.own sL UNCONNECTED PIPE CROSSING OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING. IFAl WATER EFFICIENT LANDSCAPING STANDARDS AND ORDINANCE DISCREPANCIES IN CONSTRUCTION DETAILS, LEGEND, NOTES, OR SPECIFICATIONS ARE DISCOVERED, BRING ALL SUCH POINT-OF-CONNECTION ASSEMBLY OBSTRUCTIONS OR DISCREPANCIES TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. TIE OTYOFASFEx I BACKFLOW PREVENTION ASSEMBLY: FEBCo 825-YA 5. THE DRAWINGS ARE DIAGRAMMATIC. THEREFORE, THE FOLLOWING SHOULD BE NOTED: (-- (r MASTER VALVE ASSEMBLY: RAIN BIRD PESB A. ALTHOUGH IRRIGATION COMPONENTS MAY BE SHOWN WATER EFFICIENT LANDSCAPE WORKSHEET-WATER BUDGET ANALYSIS ❑F FLOW SENSOR ASSEMBLY: RAIN BIRD FS100B OUTSIDE PLANTING AREAS FOR CLARITY, INSTALL IRRIGATION PIPE AND WIRING IN LANDSCAPED AREAS WHENEVER POSSIBLE. Note: Project Applicant must complete this n'orkstieet as it is a required element of the Landscape&Irrigations Documentation Package N ISOLATION GATE VALVE ASSEMBLY: MATCO 514 B. TREE AND SHRUB LOCATIONS AS SHOWN ON LANDSCAPE SECTION-A-G:%LLONSOFWATERNEEDEDBYPLANTCATEGDRYANDIRRIGATIONTYPE: e QUICK COUPLING VALVE ASSEMBLY:RAIN BIRD 5RC PLANS TAKE PRECEDENCE OVER IRRIGATION EQUIPMENT LOCATIONS. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING The specific ini Galion water needs of each hydrozone in the design should be determined using the followingformulaandfactors: , REMOTE CONTROL VALVE ASSEMBLY FOR SPRINKLER LATERALS MATERIALS, AND ARCHITECTURAL FEATURES. HUNTER ICV (SIZED PER PLAN) C. USE ONLY STANDARD TEES AND ELBOW FITTINGS. USE OF TEES IN THE BULLNOSE CONFIGURATION, OR USE OF Irrigation Rater Budget=l(ETox Plant F actor)-Re]xIrrigated Area+Irrigation Efficiency 0.623 ® REMOTE CONTROL DRIP VALVE ASSEMBLY: RAINBIRD XCZ-FRB-100-COM CROSS TYPE FITTINGS IS NOT ALLOWED. VA.r FLUSH CAP ASSEMBLY 6. PROVIDE THE FOLLOWING COMPONENTS TO THE OWNER PRIOR TD THE COMPLETION OF THE PROJECT: Where: W i___INDICATES CONTROLLER AND STATION NUMBER A. TWO (2) OPERATING KEYS FOR EACH TYPE OF MANUALLY ETo=Reference Evapotranspiration=27.4 incheslseason(May through September) ii OPERATED VALVES. Re=Effective Precipitation=6.8 inches/season(M ay through September) Al �-INDICATES LATERAL DISCHARGE (GPM) Irrigated Area=Hydrozone Area in Square Feet 1" 7. SELECT NOZZLES FOR SPRAY AND ROTARY SPRINKLERS WITH ARCS WHICH PROVIDE COMPLETE AND ADEQUATE COVERAGE 1.00 INDICATES VALVE SIZE (INCHES) WITH MINIMUM OVERSPRAY FOR THE SITE CONDITIONS. CAREFULLY ADJUST THE RADIUS OF THROW AND ARC OF COVERAGE OF EACH ROTARY SPRINKLER TO PROVIDE THE BEST PERFORMANCE. Water U se Category Plant Factor Irrigation Method Default Efficiency 30 PSI' INDICATES PRECIPITATION RATE Cool Season Turf 0.90 Overhead 75% U 8. THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF IRRIGATION SLEEVING. SLEEVES ARE REQUIRED �------INDICATES DESIGN PRESSURE High 0.80 Drip 90% FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OA IRRIGATION CONTROLLER UNIT WITH WEATHERSTATION OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED Medium 0.65 CONTROLLER A:Rain bird ESP-LXMEF. 7 Stations WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. PIPE SLEEVES SHALL BE SIZED TWICE THE NOMINAL Low 0.40 I- SIZE OF THE PIPE PASSING THROUGH. CONTROL WIRES IN CONDUIT OR WITH WARNING TAPE Very Low 025 9. INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC e a POP-UP SPRAY SPRINKLER: HUNTER PROS-06-PRS30-CV W/5 SERIES NOZZLE CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. PRESSURE: 30 PSI RADIUS: 5 FEET FLOW (GPM): Q-0.12 H-0.23 F-0.47 10. THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE SECTION B.HYDROZONE INFORMATION TABLE AND WATER BUDGE TC.ALCULATION: IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE Complete the hydrozone table for each hydrozone.Use as many rows as necessary to provide the square footage of landscape areaper hydrozone. II O- ■ POP-UP SPRAY SPRINKLER: HUNTER PROS-06-PRS30-CV W/8 SERIES NOZZLE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. PRESSURE: 30 PSI RADIUS: 8 FEET FLOW (GPM): Q-0.24 H-0.47 F-0.97 11. INSTALL TWO (2) 1114 AWG CONTROL WIRES ON STANDARD WIRE SYSTEMS FOR USE AS SPARES. INSTALL SPARE WIRES Reference ET FROM CONTROLLER LOCATION TO EACH DEAD-END OF MAINLINE. COIL 3 FEET OF WIRE IN VALVE BOX. 27.4 inches/year I ' I 0 0 • POP-UP SPRAY SPRINKLER: HUNTER PROS-06-PRS30-CV W/10 SERIES NOZZLE 17.1 galions/square foot 1 1 1 PRESSURE 30 PSI RADIUS, 10 FEET 12. CONTRACTOR SHALL USE FLOW CONTROL ON ALL ZONE CONTROL VALVES To ACHIEVE DESIGN PRESSURE AT THE MOST FLOW (GPM), Q-0.42 H-0.88 F-1.59 REMOTE OR HIGHEST ELEVATION DEVICE ON EACH ZONE. SEE LEGEND AND VALVE DESIGNATORS FOR EQUIPMENT DESIGN PRESSURE. Effect lye Precdpttation A r. ♦ POP-UP SPRAY SPRINKLER: HUNTER PROS-06-PRS30-CV W/12 SERIES NOZZLE 6.8inches/year /r PRESSURE 30 PSI RADIUS: 12 FEET 13. ALTHOUGH TRESS AND SHRUBS WITH DIFFERENT WATER REQUIREMENTS ARE IRRIGATED ON THE SAME DRIP ZONE, THE 4.2 ga I Ions/square foot Z \L FLOW (GPM): Q-0.57 H-1.30 F-2.70 CONTRACT5oR SHALL REFER To THE EMITTER SCHEDULE IN THE IRRIGATION DETAILS TO INSTALL THE CORRECT SIZE AND Ike LLJ r , QUANTITY OF EMITTERS PER PLANT WATER REQUIREMENTS. REFER TO LANDSCAPE PLANS FOR SPECIFIC PLANT SPECIES • U o • POP-UP SPRAY SPRINKLER: HUNTER PROS-06-PRS30-CV W/15 SERIES NOZZLE AND WATER REQUIREMENTS. Hydrozone Plant Water Need CID 30 PSI RADIUS: 15 FEET Hydrozone Plant Water e Type{s) Plant Factor Irrigation Method Irrigation Efficiency Area \\J FLOW (GPM): Q-0.97 H-1.86 F-3.75 14. SENSORS (EG., RAIN, FREEZE, WIND, AN/OR SOIL MOISTURE ETC.), EITHER INTEGRAL OR AUXILIARY, THAT SUSPEND OR (Sq.Ft.) (gal/season) / 0 ALTER IRRIGATION OPERATION DURING UNFAVORABLE WEATHER CONDITIONS OR WHEN SUFFICIENT SOIL MOISTURE IS Zonel(A4J Cod Season Turf 0.90 Overhead 75% 228 3,383 • -POP-UP SPRAY SPRINKLER: HUNTER PROS-06-PRS30-CV PRESENT SHALL BE REQUIRED ON ALL IRRIGATION SYSTEMS. W/15SS SERIES NOZZLE, PRESSURE: 30 PSI PATTERN: 5 X 15 FEET Zone 2(Aspens A2,A5) Medium 0.65 Drip 90% 72 549 FLOW GPM: ES515-0.55 SS530-1.30 Zone 3(A1-A2,A5-A7) Low 0.40 Overhead 75% 1477 5,104 Zone 4(WF) Cool Season Turf 0.90 Overhead 75% 80 1,187 Zones(Spa) Cool Season Turf 0.90 Drip 50 618 _1CONSTRUCTION NOTES TOTAL 1907 10,840 OEAVERAGE IRRIGATION WATER NEED•ALL ZONES'•In gallons/sq.ft./season 5.7 n 0 THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE DOWNSTREAM OF THE IRRIGATION WATER TAP AND METER LJ INSTALLED BY OTHERS AT THE APPROXIMATE LOCATION SHOWN. INSTALL BACKFLOW PREVENTION UNIT AND MASTER VALVE ASSEMBLY •The average must be less than the Maxl mum Applied Water Budget of 7.5gallons/sq.ft./season. 1 AS INDICATED, SAME SIZE AS POC. VERIFY EXACT LOCATION OF POC WITH OWNER'S REPRESENTATIVE. 2 WALL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE Total area of irrigated publicdght-of-way: ^Sp.Ft. I COO CONTROLLER WITH THE OWNER'S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE IRRIGATION CONTROLLER IN A Total area of non-I nl gated landscape: DSQ.Ft. Q CO LOCATION THAT IS ACCESSIBLE FOR MAINTENANCE, AND SCREENED FROM VIEW EITHER BEHIND ENTRY WALLS, NEXT TO BUILDINGS, OR \.% - CD BEHIND PLANT MATERIAL. FINAL LOCATION TO BE APPROVED BY OWNER'S REPRESENTATIVE. CO 0 W co OIRRIGATION CONTRACTOR SHALL INSTALL LOCKABLE GATE VALVE ASSEMBLY PER CITY REQUIREMENTS UPSTREAM OF THE BACKFLOW [] z O ASSEMBLY UNIT AT THE APPROXIMATE LOCATION SHOWN. Q > OIRRIGATION SHOWN OUT OF LANDSCAPED AREA FOR CLARITY ONLY. INSTALL IRRIGATION COMPONENTS WITHIN LANDSCAPED AREA. As per WELS Section CC 4.3.3(c) In 9 Q J OIRRIGATION CONTRACTOR SHALL PROVIDE A 1-INCH REFILL LINE TO WATER FEATURE BASIN AT APPROXIMATE LOCATION SHOWN. water-features have 0 ❑ Q a.75 irrigation ❑ OTHE IRRIGATION CONTRACTOR SHALL PROVIDE THE APPROPRIATE QUANTITY/SIZE OF EMITTERS TO EACH PLANTING MATERIAL AS efficiency.Revise. U = U z SPECIFIED IN THE EMITTER SCHEDULE DETAIL #13 & IN ACCORDANCE WITH THE COLORADO RECOMMENDED PLANTING LIST z O HYDROZONE REQUIREMENTS FROM THE CITY of ASPEN. 4--Um LL) U LLJ a- N. °Q 1 1 gCU C.) CITY OF ASPEN GENERAL NOTES Designed: JF,MR Drafted: JF 1. APPLICANT IS RESPONSIBLE FOR ASSURING OPERATING PRESSURE AT EACH EMISSION DEVICE IS WITHIN THE Reviewed: MR MANUFACTURER'S RECOMMENDED PRESSURE RANGE FOR OPTIMAL PERFORMANCE. IF PRESSURE IS NOT WITHIN Date Issued: THE PREFERRED RANGE, ACTIONS DESCRIBED IN SECTION 6.1.10 OF THE WATER EFFICIENT LANDSCAPING 03.0e.2019 STANDARDS MUST BE TAKEN. Revision Title Date 2. SPRINKLERS WITHIN INDIVIDUAL IRRIGATION ZONE SHALL HAVE MATCHED PRECIPITATION PATES, UNLESS 1 City Comments 2018.03.27 OTHERWISE DIRECTED BY THE MANUFACTURER'S RECOMMENDATIONS. 2 City Comments 2019.03.06 3. ENSURE THERE IS HIGHEST POSSIBLE DISTRIBUTION UNIFORMITY, AND HEAD-TO-HEAD COVERAGE. 4. AN IRRIGATION MAINTENANCE SCHEDULE AND IRRIGATION MANAGEMENT PLAN IS REQUIRED AS DESCRIBED IN 3 Arch Revisions 2019.06.26 SECTION 6.7 THROUGH 6.9 OF THE STANDARDS. 4 Land Revisions 2019.09.26 HAVE COMPLIED WITH THE CRITERIA OF THE WATER EFFICIENT LANDSCAPING STANDARDS AND 5 Spa Revisions 2020.02.13 ENSURE THE FOLLOWING: APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE IRRIGATION DESIGN PLAN e 7 1. TURF GRASS SPRINKLER HEADS SHALL HAVE A DISTRIBUTION UNIFORMITY OF 0.65 OF HIGHER USING THE PROTOCOL DEFINED IN ASABE/ICC 802-2014 ilk 2. POP-UPS IN TURF AREAS HAVE A MINIMUM HEIGHT OF 6". 3. SPRINKLER SPACING SHALL BE DESIGNED TO ACHIEVE THE HIGHEST POSSIBLE DISTRIBUTION UNIFORMITY USING THE MANUFACTURER'S RECOMMENDATIONS. SPACING MUST ACHIEVE HEAD-TO-HEAD COVERAGE. ALL SPRINKLER HEADS INSTALLED IN THE TURF GRASS AREAS SHALL HAVE A DISTRIBUTION UNIFORMITY OF 0.65 OR HIGHER 02/13/2020 USING THE PROTOCOL DEFINED IN ASABE/ICC 802-2014 STANDARD. Sheet Title: 4. THE IRRIGATION SYSTEM MUST BE DESIGNED AND INSTALLED TO MEET, AT A MINIMUM, ANY WATER WINDOWS OR NAME DATE IRRIGATION LEGEND G.NOTES RESTRICTIONS FOR OPERATION SUCH AS DAY OF THE WEEK AND HOURS OF THE DAY. EDWARD W PRICE, CID, CLIA 5. SPRINKLERS WITHIN ZONE SHALL HAVE MATCHED PRECIPITATION RATES, UNLESS OTHERWISE DIRECTED BY THE D50322 Sheet Number MANUFACTURERS RECOMMENDATIONS. I R 1 .0 6. APPLICATION RATE ON SLOPES GREATER THAN 25% SHALL NOT EXCEED 0.75 INCHES PER HOUR 7. ANY WORK PERFORMED UNDER PROTECTED TREES REQUIRES HAND GRUBBING NO DEEPER THAN 4 INCHES (4"). ANY ADDITIONAL SOIL ABOVE EXISTING GRADE LIMITED TO A MAXIMUM 3 INCHES 3"). CONSTRUCTION NOTES A-,..._ Hines Inc OTHE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE DOWNSTREAM OF THE IRRIGATION WATER TAP AND METER INSTALLED BY OTHERS AT THE APPROXIMATE LOCATION SHOWN. INSTALL BAC KFLOW PREVENTION UNIT AND MASTER VALVE ASSEMBLY SITE WATER ENGINEERING SERVICES AS INDICATED, SAME SIZE AS POC. VERIFY EXACT LOCATION OF POC WITH OWNER'S REPRESENTATIVE. 323 W.DRAKE RD,SUITE 204 FORT COLLINS,COLORADO 80526 OWALL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE Telephone:970.282.1800 CONTROLLER WITH THE OWNER'S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE IRRIGATION CONTROLLER IN A Web:www.hinesinc.eom LOCATION THAT IS ACCESSIBLE FOR MAINTENANCE, AND SCREENED FROM VIEW EITHER BEHIND ENTRY WALLS, NEXT TO BUILDINGS, OR \ BEHIND PLANT MATERIAL. FINAL LOCATION TO BE APPROVED BY OWNER'S REPRESENTATIVE. OIRRIGATION CONTRACTOR SHALL INSTALL LOCKABLE GATE VALVE ASSEMBLY PER CITY REQUIREMENTS UPSTREAM OF THE BAC KFLOW • ' ASSEMBLY UNIT AT THE APPROXIMATE LOCATION SHOWN. � • . ' OIRRIGATION SHOWN OUT OF LANDSCAPED AREA FOR CLARITY ONLY. INSTALL IRRIGATION COMPONENTS WITHIN LANDSCAPED AREA. g • OIRRIGATION CONTRACTOR SHALL PROVIDE A 1-INCH REFILL LINE TO WATER FEATURE BASIN AT APPROXIMATE LOCATION SHOWN. • , .•OTHE IRRIGATION CONTRACTOR SHALL PROVIDE THE APPROPRIATE QUANTITY/SIZE OF EMITTERS TO EACH PLANTING MATERIAL AS ` / \�SPECIFIED IN THE EMITTER SCHEDULE DETAIL #13 & IN ACCORDANCE WITH THE COLORADO RECOMMENDED PLANTING LIST / ..HYDROZONE REQUIREMENTS FROM THE CITY OF ASPEN. 1, �, w ti j _ n ��- •„ ,______ __„:„.„„.:.,..:• re .\ A 1 _ f 2�a\v\\\. •..• N . ••1: \\' \ IRRIGATION LEGEND t Liw,, i i _ ) 1.11 RoAl SLEEVES: CLASS 200 PVC / \ A. MAINLINE PIPE: CLASS 200 PVC �� 1 1/4 INCH SIZE UNLESS OTHERWISE INDICATED ��� LATERAL PIPE TO SPRINKLERS. CLASS 200 PVC � H /:��....1 I'� rJ '�� 1-INCH UNLESS OTHERWISE INDICATED m /�//�� I`1� j , OL...... {"`' : U SD LATERAL PIPE TO EMITTERS: UV RADIATION RESISTANT MI %/ ��•� ® '< W POLYETHYLENE (3/4-INCH SIZE, ROUTING IS DIAGRAMMATIC) ® d� lift �� It �L UNCONNECTED PIPE GROSSING 30P I 01 '// �• ///./y�/ . ,.. .. POINT-OF-CONNECTION ASSEMBLY ///�i . . , AI ---- ��t I BACKFLOW PREVENTION ASSEMBLY: FEBCO 825-YA ./ 1 �i;�� A.ir P O C O /®I�. U MASTER VALVE ASSEMBLY: RAIN BIRD PESB jjr SIZE: 3/4-INCH4 30 PSI fY Q PRESSURE: PSI iiity,f.1 A7 LL " �/ FLOW: 10 GPM Q 0 FLOW SENSOR ASSEMBLY: RAINBIRD FS100B �' ay��� �/ CONTROLLER 6.97 N ISOLATION GATE VALVE ASSEMBLY: MATCO 514 ©41##,:" CAN I\OLLLI\O Native w i,. ® QUICK COUPLING VALVE ASSEMBLY:RAINBIRD SRC `- 41 120 VAC POWER REQUIRED Alik !� w f• REMOTE CONTROL VALVE ASSEMBLY FOR SPRINKLER LATERALS 44 AI-Ail,NTER Icv (SZED PER P AN) LEI NS ALLATON GENERAL NOTES REMOTE CONTROL DRIP VALVE ASSEMBLY: RAINBIRD XCZ-PRB-100-CON / 7/ Ui ® 1. THE SYSTEM DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE FOR THE IRRIGATION SYSTEM OF 60 PSI (MINIMUM Z • . REQE� A MAXMUM DISCHARGE OF 10 GPM AT THE 3/4-INCH IRRIGATION POINT-OF-CONNECTION (POC). TAP,ELM�L� FLUSH CAP ASSEMBLY y ./ / MET KFLOW, AND MASTER VALVE SHALL ALL BE THE SAME SIZE. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CO�� �/ . 30PSI coNSTRucrloN. "�; ji,INDICATES CONTROLLER AND STATION NUMBER /Al ( 2. READ THOROUGHLY AND BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED ❑ r-INDICATES LATERAL DISCHARGE (GPM) ` lam WORK PRIOR TO CONSTRUCTION. �" 14 Z 1" INDICATES VALVE SIZE (INCHES) fill* Ill/ . � - 3. COORDINATE UTILITY LOCATES ("CALL BEFORE YOU DIG') OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. 1.00 30 PSI��INDICATES PRECIPITATION RATE 'jam ''' /' ',i 4. DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM WHEN IT IS OBVIOUS IN THE FIELD THAT _�INDICATES DESIGN PRESSURE ,�/ \------- /f' +4 OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING. IF 1� DISCREPANCIES IN CONSTRUCTION DETAILS LEGEND NOTES OR SPECIFICATIONS ARE DISCOVERED, BRING ALL SUCH OA IRRIGATION CONTROLLER UNIT WITH WEATHERSTATION OO \\S%/ .� - / O OBSTRUCTIONS OR DISCREPANCIES TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. 00 CONTROLLER A:Roinbird ESP-LXMEE 7 Stations • `� - 5. THE DRAWINGS ARE DIAGRAMMATIC. THEREFORE, THE FOLLOWING SHOULD BE NOTED: I ' I CONTROL WIRES IN CONDUIT OR WITH WARNING TAPE • • I �� 1" 1 i �� �' Shmb /A. ALTHOUGH IRRIGATION COMPONENTS MAY BE SHOWN ❑K POP-UP SPRAY SPRINKLER: HUNTER PROS-06-PRS30-CV W/s SERIES NOZZLE ��% r' 30 PSI OUTSIDE PLANTING AREAS FOR CLARITY, INSTALL PRESSURE: 30 PSI RADIUS: 5 FEET �� � \� IRRIGATION PIPE AND WIRING IN LANDSCAPED AREAS FLOW (GPM): Q-0.12 H-0.23 F-0.47 ® �. �� I►,�' WHENEVER POSSIBLE. CO al 0 / aCO 0CDCYj O- ■ POP-UP SPRAY SPRINKLER: HUNTER PROS-O6-PR530-CV W/8 SERIES NOZZLE 3OPSI �- , B. TREE AND SHRUB LOCATIONS AS SHOWN ON LANDSCAPE CO W PRESSURE 30 PSI RADIUS. 8 FEET `-� © PLANS TAKE PRECEDENCE OVER IRRIGATION EQUIPMENT LOCATIONS. 0 FLOW (GPM): Q 024 H 047 F 0.97 4._. �� - AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING z O giNW� �� MATERIALS, AND ARCHITECTURAL FEATURES. Q ❑ C 0 • POP-UP SPRAY SPRINKLER HUNTER PROS-06-PRS30-CV W/10 SERIES NOZZLE ,,--'��i ��`�`�`" -- /- e`„ 6.4 C. USE ONLY STANDARD TEES AND ELBOW FITTINGS. USE OF TEES IN THE BULLNOSE CONFIGURATION, OR USE OF PRESSURE: 30 PSI RADIUS: 10 FEET - /( CC cc FLOW(GPM): Q-0.42 H-0.88 F-1.59 .�y'�� �� \`� ® 1CROSS TYPE FITTINGS IS NOT ALLOWED. 1 ^ QJf u J QDisturbance caused b ,``,"��""�` s 1311'. 30 PSI 6. PROVIDE THE FOLLOWING COMPONENTS To THE OWNER PRIOR TO THE COMPLETION of THE PROJECT: J ❑ r. ♦ POP-UP SPRAY SPRINKLER: HUNTER PROS-06-PRS30-CV W/12 SERIES NOZZLE y p� 0 Ti ❑ PRESSURE: 30 PSI RADIUS: 12 FEET irrigation lines in driplines of _ it U [� z FLOW(GPM} Q-0.67 H-1.30 F-2.70 existing trees is limited by /7 A. TWO (2) OPERATING KEYS FOR EACH TYPE OF MANUALLY - OPERATED VALVES. Z O WELStyF Section 4 3 2(m).evThe I W r , a W m o • POP-UP RES SPRAY SPRINKLER: HUNTER PROS-06-PRS30-0v w/15 SERIES NOZZLE City Forester may be even _• / \Y`\ 7. SELECT NOZZLES FOR SPRAY AND ROTARY SPRINKLERS WITH ARCS WHICH PROVIDE COMPLETE AND ADEQUATE COVERAGE b, `o O_ v- a� CC PRESSURE: 30 PSI RADIUS: 15 FEET mo estriotive in that regard. ® „.•--, FLOWWITH MINIMUM OVERSP RAY FOR THE SITE CONDITIONS. CAREFULLY ADJUST THE RADIUS OF THROW AND ARC OF m(n FLOW (GPM): Q-0.97 H-1.86 F-3.75 A tree pe . may be required 10 PSI -='�i COVERAGE OF EACH ROTARY SPRINKLER TO PROVIDE THE BEST PERFORMANCE. a�3 Q ��; 12C co CCU U • .. POP-UP SPRAY SPRINKLER: HUNTER PROS-06-PRS30-CV for Atreeturbancei e W/15SS SERIES NOZZLE, PRESSURE: 30 PSI PATTERN 5 X 15 FEET driplines.Revise plan / -- '--__. 8. THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF IRRIGATION SLEEVING. SLEEVES ARE REQUIRED Designed: JF,MR FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HAROSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH Drafted: JF FLOW GPM: ES515-0.65 SS530-1.30 accordingly. 1! OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. PIPE SLEEVES SHALL BE SIZED TWICE THE NOMINAL Reviewed: MR j SIZE OF THE PIPE PASSING THROUGH. Date Issued: Ovate 12.21.201E rs 9. INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. Revision Title Date A Ve r4e \ 10. THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF UNSI ZED PIPE IS LOCATED BETWEEN THE I City Comments 2018.03.27 IDENTICALLY SIZED SECTIONS, THE UNSI ZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE 2 City Comments 2019.03.08 UNSIZEO PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. _ 3 Arch Revisions 2019.06.26 11. INSTALL TWO (2) #14 AWG CONTROL WIRES ON STANDARD WIRE SYSTEMS FOR USE AS SPARES. INSTALL SPARE WIRES 4 Land Revisions 2019.09.26 FROM CONTROLLER LOCATION TO EACH DEAD-END OF MAINLINE. COIL 3 FEET OF WIRE IN VALVE BOX. 5 Spa Revisions 2020.02.13 12. CONTRACTOR SHALL USE FLOW CONTROL ON ALL ZONE CONTROL VALVES TO ACHIEVE DESIGN PRESSURE AT THE MOST e REMOTE OR HIGHEST ELEVATION DEVICE ON EACH ZONE. SEE LEGEND AND VALVE DESIGNATORS FOR EQUIPMENT DESIGN 7 PRESSURE. 13. ALTHOUGH TRESS AND SHRUBS WITH DIFFERENT WATER REQUIREMENTS ARE IRRIGATED ON THE SAME DRIP ZONE, THE CONTRACT50R SHALL REFER TO THE EMITTER SCHEDULE IN THE IRRIGATION DETAILS TO INSTALL THE CORRECT SIZE AND El IN QUANTITY OF EMITTERS PER PLANT WATER REQUIREMENTS. REFER TO LANDSCAPE PLANS FOR SPECIFIC PLANT SPECIES AND WATER REQUIREMENTS. IO' 14' 18' 116' R, 14. SENSORS (EG., RAIN, FREEZE, WIND, AN/OR SOIL MOISTURE ETC.), EITHER INTEGRAL OR AUXILIARY, THAT SUSPEND OR SCALE 1/8"=1'-0"N 0 R T El ALTER IRRIGATION OPERATION DURING UNFAVORABLE WEATHER CONDITIONS OR WHEN SUFFICIENT SOIL MOISTURE IS Sheet Title: PRESENT SHALL BE REQUIRED ON ALL IRRIGATION SYSTEMS. IRRIGATION PLAN Sheet Number I R 2.0 A-,...._ Hines Inc SITE WATER ENGINEERING SERVICES 323 W.DRAKE RD,SUITE 204 FORT COLLINS,COLORADO 80526 Telephone:970.282.1800 Web:www.hinesinc.com VALVE BOX WITH LOCKING COVER: CARSON 1419-4B. SECURE CHRISTY ID TAG WITH NYLON ALUMINUM ENCLOSURE: BRAND LID WITH "MV" ZIP TIE. LABEL WITH CONTROLLER AND STRONGBOX SBBC-30AL OR STATION NUMBER. ,���/ yyy� FINISH GRADE GUARDSHACK GS-2 FINISH GRADE/TOP OF MULCH �5 REDUCED PRESSURE BACKFLOW s. I SECURE CHRISTY ID TAG WITH NYLON VALVE BOX WITH LOCKING COVER: VALVE BOX WITH COVER: � PREVENTER PER LEGEND J = -.\ f.' ZIP TIE. LABEL WITH CONTROLLER AND CARSON 1419-4B. BRAND "FM" ON 2-INCH MIN CARSON 910-4. I STATION NUMBER. y LID W/ 3-INCH HIGH LTRS. BRAND LID WITH VALVE "IGV" •�•��• BRASS UNION (1 OF 2) i mm a _MNIa I /i� 9 ? CC n 3/4-INCH MALE ADAPTER WITH PVC 30-INCH LINEAR LENGTH OF �-. CAP 4-INCH PVC CL 200 PIPE I .. COILED WIRE FINISH GRADE/TOP OF MULCH •• I (LENGTH AS REQUIRED) D 6-INCH CONCRETE PAD, 6-INCHES WATER PROOF CONNECTION (1 OF 2) •0oo�o. �•1 LARGER THAN ENCLOSURE (EACH SIDE) TWO (2) CONDUCTOR TWISTED PAIR -000. jE,_ I SHIELDED DIRECT BURIAL CABLE FOR O° o 0 3-INCH MINIMUM DEPTH OF �I,I�,;;i,,,iii;,�.�,1 MASTER VALVE, SIZE TO MATCH POC °� 3/4-INCHr , TYPE L COPPER (SIZED TO MATCH MODEL PER LEGEND CONNECTION TO TRANSMITTER (1 WASHED GRAVEL �J ef '� BACKFLOW) )107 1 H I WATER PROOF CONNECTION (1 OF 2) BRICK 1 OF 2 3-INCH MINIMUM DEPTH OF 1 3M SERIES 7000 EPDXY KIT ► ( ) W � 3-INCH SLEEVE (1 OF 2) FINISH I` GRADE !I 3/4-INCH WASHED GRAVEL _ FLOW SENSOR PER LEGEND i GATE VALVE WITH CROSS HANDLE, CLASS 200 PVC MAINLINE TO MASTER VALVE 0 PVC MAINLINE TO SYSTEM "' SIZED TO MATCH MAINLINE. MODEL SCH 40 PVC MALE ADAPTER (SIZED TO - ==�' o 0000 0 0i go`b Mw.10 PIPE olA.� f MIN.5 PI. DIA.► __� PER LEGEND 000 cP0°Oodo STRAIGHT PIPE • In MATCH BACKFLOW) o°000ro°ago m °oo°� sTRAIGHr�E0 COPPER FEMALE ADAPTER BRICK (1 OF 4) ' FLOW—+• '1.*■1nM PVC MAINLINEI IPVC MAINLINEPVC SCH 40 MALE ADAPTER (SPEARS 000 oco� 9gOoo°o=;000:OQo°9' �I ��I TYPE K COPPER FROM METER (SIZED SR-2-0801) �1 °000 oo° ,,600a�o o°oo!P° MI BRICK (1 OF 4) Q TO MATCH BACKFLOW) NON-WOVEN LANDSCAPE FABRIC PVC SCH. 40 MALE ADAPTER I I I NOTES: SCH 40 PVC MALE ADAPTER (SPEARS 436 SERIES) 1. INSTALL BACKFLOW DEVICE IN ACCORDANCE WITH ALL STATE AND LOCAL CODE REQUIREMENTS. (SPEARS 436 SERIES) 1 OF 2 I__L 2. SLOPE TOP SURFACE OF PAD AT 0.5 7 NOTES: WITH BROOM FINISH. MAKE PIPE SLEEVES WITH 3-INCH MINIMUM DEPTH OF 1-1/2 INCH LARGER DIAMETER PIPE THAN PENETRATING PIPE SIZE. 3/4-INCH WASHED GRAVEL 1. NOMINAL SIZE OF GATE VALVE TO MATCH NOMINAL MAINLINE SIZE. 3. ALL HINGED CONNECTION LOCATIONS AND HARDWARE TO BE TAMPER PROOF. 4. ALL WELD JOINTS SHALL BE CONTINUOUS AND GROUND SMOOTH. NON-WOVEN LANDSCAPE FABRIC . BACKFLOW PREVENTION MASTER VALVE FLOW SENSOR ISOLATION GATE LLJ U UNIT ASSEMBLY ill ASSEMBLY III ASSEMBLY 4 VALVE ASSEMBLY > o ❑ SECURE CHRISTY ID TAG WITH NYLON -....---TYPICAL RAIN/FREEZE/WIND SENSOR; a 7 ZIP TIE. LABEL WITH CONTROLLER AND 116.— PROPERLY MOUNTED ON POST OR STATION NUMBER. GUTTER TO RECEIVE FULL SUN, OPEN /r VALVE BOX WITH COVER: TO RAINFALL AND OUT OF SPRINKLER \` CARSON 910-4. VALVE BOX WITH COVER: CARSON 30-INCH LINEAR LENGTH OF WIRE, COVERAGE. 419-4. J BRAND LID WITH VALVE "QC" COILED WALL MOUNTED CONTROLLER 3-INCH MAX BRAND LID WITH VALVE NUMBER II OE FINISH GRADE WATER PROOF CONNECTION (1 OF 2) FINISH GRADE TOP OF MULCH - (REFER TO LEGEND FOR MODEL) II / COMMUNICATION WIRE INSTALLED IN W QUICK COUPLING VALVE PER LEGEND VALVE BOX WITH COVER: CARSON 11 ' r+ WATER PROOF CONNECTION (1 OF 2) CONDUIT; MAX WIRE DISTANCE: 200'. fiyjj / 1c STAINLESS STEEL HOSE CLAMP 1419 4 BRAND LID WITH VALVE NUMBER '� a�1 30-INCH LINEAR LENGTH OF WIRE, WALL ; (WIRELESS OPTIONAL; REFER TO LEGEND) (1 OF 2) REMOTE CONTROL VALVE, SIZED AS Er IM J,I COILED .' 120 VOLT POWER SUPPLY WIRES IN I SHOWN ON DRAWINGS Iw 1 �11 REMOTE CONTROL VALVE, SIZED AS - METAL CONDUIT CU U I_ 36-INCH No. 6 EPDXY COATED REBAR ■■-- -� _ L SHOWN ON DRAWINGS - • - I�N. FINISH GRADE/TOP OF MULCH PVC CONDUIT FOR CONTROL WIRES ■— i --- .s MINIMUM 10 FT.-� ... 1 3-INCH DEPTH OF 3/4-INCH WASHED SECURE CHRISTY ID TAG WITH NYLON �r�I i� SPEARS PVC TRUE UNION BALL VALVE TO LANDSCAPED AREA CO GRAVEL � �1 �" #ZIP TIE. LABEL WITH CONTROLLER ANDAPPROVED GEOTECH FILTER FABRIC 6 BARE COPPER GROUNDING WIRE IN O BRICK 1 OF 2 STATION NUMBER. PVC SWEEP ELL0oIto ' ( ) oogo (EXTEND 10" UP BOX WALL) METAL CONDUIT O ❑ z Q 00 °ate• •oo 1 5 SIZE o° ►/ SCH 80 PVC NIPPLE, TOE \ �� I �,.o° °00000ro°' ,o° �� — PAVEMENT U (LENGTH VARIES) �� SPEARS PVC TRUE UNION BALL VALVE ►, I °���/ PVC SCH 80 PIPE (LENGTH AS - Ill Mil ill ill IIII .��,� REQUIRED) PRE-FABRICATED SWING JOINT: ���� PVCSCH40ELT II®�_ I• FINISH GRADE O Q J SPEARS 5815-010-10 • ���I���I����� T' BRICK (1 OF 4) PVC MAINLINE I�III — IMJ /� ❑ LO a 1,. 1 m III III PVC SWEEP E 0 A� Q _oti\r�o o Oro°o��o°o l.` ' J� �- I� �� DIRECT BURIAL CONTROL WIRES TO U Ti 1 )_ ,g00000000 00�! BRICK (1 OF 4) ` /,� o PVC MAINLINE PIPE ° • ate°m °° PVC SCH 80 PIPE U Z ./� ��._!� PVC SCH 40 TEE OR EL �/-I�' CONTROL VALVES ENGTH AS REQUIRED) Z ❑ ❑ LOOP 1' OF 2 SPARE WIRES LLJ U aw m a PVC MAINLINE COMBINED PRESSURE REGULATOR COPPER GROUNDING WIRE SCH 40 PVC TEE OR EL WITH FPT AND Y-STRAINER TO BRONZE CLAMP. .CD o a r C[ OUTLET —�� COPPER CLAD GROUND ROD m(n .m Q PVC SCH 4D TEE OR EL 3.0-INCH MINIMUM DEPTH OFQ o 3/4-INCH WASHED GRAVEL PART NUMBER PAIGE10E0LECTRIC a��Q °� 8al U NOTE: NOTES: Designed: JF,MR PVC SCH 40 MALE ADAPTER 1. INSTALL ALL WIRING PER LOCAL ELECTRICAL CODES. 1. USE BARBED INSERT FITTINGS ON DRIP LATERAL PIPE WITH STAINLESS STEEL HOSE Drafted: JF (SPEARS SR-2-0801) 2. INSTALL GROUND ROD WITHIN IRRIGATED TURF AREA. IF IRRIGATED TURF AREA IS NOT IN CLAMPS. PLACE CLAMPS ON DRIP TUBING DIRECTLY OVER BARBED AREA OF FITTING. Reviewed: MR 3.0-INCH MINIMUM DEPTH OF PINCH CLAMPS ARE NOT ACCEPTABLE. CLOSE PROXIMITY TO CONTROLLER, INSTALL ONE (1) DRIP EMITTER FROM NEAREST DRIP 3/4-INCH WASHED GRAVEL VALVE IN VALVE BOX HOUSING GROUNDING ROD. Date Issued: 12.21.201 ES O QUICK COUPLING 6 REMOTE CONTROL TURF O REMOTE CONTROL DRIP 8 WALL MOUNT Revision Title Date VALVE ASSEMBLY VALVE ASSEMBLY VALVE ASSEMBLY CONTROLLER ASSEMBLY 1 City Comments 2018.03.27 2 City Comments 2019.03.08 3 Arch Revisions 2019.06.26 4 Land Revisions 2019.09.26 5 Spa Revisions 2020.02.13 a 7 Sheet Title: IRRIGATION DETAILS Sheet Number IR3.0 AHines Inc SITE WATER ENGINEERING SERVICES 323 W.DRAKE RD,SUITE 204 FORT COLLINS,COLORADO 80526 Telephone:970.282.1800 Web:www.hinesinc.com RAIN BIRD MODEL # DBC-025 SPRAY NOZZLE, PER PLAN: DIFFUSER BUG CAP SEE LEGEND FOR MODEL DIFFUSER BUG CAP: VALVE BOX WITH COVER: CARSON 708-4. 11�,,1,1,,�� dd 1 { RAIN BIRD MODEL DBC-025 MULCH BRAND LID WITH "FC" W 1�,41i.I�Al 11,1V.111��,a��l�r,1,Adl� FINISH GRADE/TOP OF MULCH 1/4-INCH TUBING STAKE: FINISH GRADE _ MiNiEr= _ _ - RAIN BIRD #TS-025 CE - - i- i I, i i .� u y. FINISH GRADE/TOP OF MULCH 1 4-INCH DISTRIBUTION TUBING i i i i \i\ POP-UP SPRAY BODY: �'�=; i� ; ..,_ �/�� ' WITH CHECK VALVE AND PRESSURE MULCH BED `1;iV'9 \ \ V / A REGULATING VALVE FEATURES �� //�i0�/�/�/�A V /� \� i / RAIN BIRD MODEL #TS-025 V FLUSH CAP: 3/4-INCH BARB X SEE LEGEND FOR MODEL Y///r/0/,. r r y i /r. 1/4" TUBING STAKE(TYPICAL) 4 ! 3/4-INCH M NPT ADAPTER AND DRIP EMITTER THREADED CAP sr (REFER TO SPECIFICATIONS) �"....... �m W 1/2-INCH MALE NPT x .490 INCH //ham /// /)/ / / �`�� 1/4-INCH DISTRIBUTION TUBING 3/4-INCH DRIP LATERAL PIPE (MIN BARB ELBOW: RAIN BIRD MODEL //� /////// /�� / S� 12-INCHES LOOPED) H \�I , SBE-050 ///. //�� ak., �� RAIN BIRD MODEL # XB-10-6 \ . / // MULTI-OUTLET XERI-BUG EMITTER 3-INCH DEPTH OF 3/4-INCH �j /2/ �� j Mn.. WASHED GRAVEL ' FINSH GRADE `KD"aLo�Po"sb� 3/4-INCH MALE BARBED ELBOW oa" po 00 c° t; ,- 00 �� •PVC LATERAL PIPE /�/�/ /�/�/�/�/ / " o"o °"o`o..� _�o°O�° A V�V� V�iA�iA�iA�V V DRIP LATERAL TUBING ° _; ago mWilma BRICK (1 OF 2) 11 °ia ° DRIP EMITTER BOX o Illi l" 3/4-INCH DRIP LATERAL PIPE Q PVC SCH. 40 TEE OR EL DRIP LATERAL PIPE 3/4" CRUSHED STONE I I I SWING PIPE, 12-INCH LENGTH: PLANT ROOT BALL 1 1 1 RAIN BIRD SPS-FLEX100 I__L NOTE: 1. LOOP IRRIGATION DRIP TUBING INSIDE VALVE BOX FOR EXTENSION OUTSIDE OF BOX DURING BLOWOUT. 9 6-INCH POP UP SPRAY 10 SINGLE OUTLET DRIP (II) MULTI-OUTLET DRIP EMITTER DRIP FLUSH CAP w SPRINKLER ASSEMBLY EMITTER ASSEMBLY ASSEMBLY FOR TREES IN BEDS e ASSEMBLY > MAINLINE, LATERAL, PIPE AND WIRE PAVED SURFACE CHRISTY ID TAG Z PLANT TYPE BY EMITTERS GPH PER TOTAL GPH LATERAL PIPE CURB AND GUTTER IF APPLICABLE — FINISHED GRADE '^ <74 HYDROZONE PER PLANT EMITTER PER PLANT 24 V WIRE SEEEVING " MIN IRRIGATION CONTROL WIRES SECURED V♦1 FINISH GRADE CONCRETE SLAB TO BOX WITH NYLON ZIP TIE. OE 36" IRRIGATION VALVE/SENSOR ASSEMBLYEL LOW WATER USE TREE 3 SINGLE 1 GPH 3 GPH 12" MIN (ABOVE GRAVEL) W �I 3.0-INCH MINIMUM DEPTH OF MED WATER USE TREE 4 SINGLE 1 GPH 4 GPH '/� ROUGH GRADE 1_ 18' 0 3/4 INCH WASHED GRAVEL ' _ P�`, 8%� �' o0000 24" IIHII 2' PVC PIPE SLEEVE MARKER INSTALL AT °O��" .e°Oo. BRICK 1 OF 4 HIGH WATER USE TREE 3 SINGLE 2 GPH 6 GPH III III III ( ) II I I BOTH ENDS of EACH SLEEVE LOCATION AND CO CUM 24" III �J,�Jf EXTEND AT LEAST 3 ABOVE GRADE. SPRAY APPROVED GEOTECH FILTER FABRICCD LOW WATER USE SHRUBS 1 SINGLE 1 GPH 1 GPH 410 ® IIII II III EXPOSED PORTION OF MARKER WITH GREEN (EXTEND:10' UP BOX WALL) CO U W �pr ,' � - FLUORESCENT PAINT. STANDARD QUICK ❑ MED WATER USE SHRUBS 2 SINGLE 1 GPH & 0.5 GPH 1.5 GPH r 1 COUPLER OR ISOLATION 4„ 24-INCH MIN l � GATE VALVE BOX Q CO � W O 0. ® III III .. HIGH WATER USE SHRUBS 2 SINGLE 1 GPH 2 GPH �T, 4 6 MIN. 4443.* > • LOW WATER USE PERENNIAL 1 SINGLE 1 GPH 1 GPH V//// TS 4 O J \ J / 0in 9 _, < ❑ Q EXCAVATED MATERIAL rT u - ❑ V 4-6' MIN. MIN 12" + STANDARD CARSON 1419 U MED WATER USE PERENNIAL 2 SINGLE 1 GPH & 0.5 GPH 1.5 GPH PIPE WIRING 1 MIN 12' REMOTE CONTROL VALVE = U Z BEDDING & COVER MATERIAL SLEEVE SLEEVE MIN 12" BOX Z `u;❑ 0 HIGH WATER USE PERENNIAL 2 SINGLE 1 GPH 2 GPH __ SEAL ENDS OF SLEEVES WITH CLOTH TURF OR PLANTING BED LLJ U aw m WARNING TAPE DUCT TAPE (TYPICAL) + b O o IZ _ ar CE NOTES: PVC SLEEVING (TYPICAL) a�,<�. m� mm Q a a PAVEMENT OR EDGING RESTRAINT Q Q 1. SLEEVE ALL PIPE AND WIRE SEPARATELY. NOTES` o_ LLL..LLL clal U NOTES: 2. ALL PIPE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS."SNAKE" UNSLEEVED NOTE: 1. INSTALL ONLY ONE RCV TO VALVE BOX. LOCATE AT LEAST 12-INCHES FROM 1. ALL EMISSION POINTS TO BE LOCATED ON THE UPHILL SIDE OF PLANT PLASTIC PIPE IN TRENCH. PROVIDE A MINIMUM OF 2" CLEARANCE TO SIDE OF TRENCH 1) ALL SLEEVING TO BE CLASS 200 BE PVC, SIZED AS NOTED. AND ALIGN WITH NEARBY WALLS OR EDGES OF PAVED AREAS. GROUP RCV Designed: JF,MR MATERIAL. AND BETWEEN PIPES. Drafted: JF 2. ALL EMITTER QUANTITIES AND FLOW RATES ARE FOR RECOMMENDATION ONLY. 2) INSTALL SLEEVES IN SIDE-BY-SIDE CONFIGURATION WHERE MULTIPLE SLEEVES ASSEMBLIES TOGETHER WHERE PRACTICAL. THE CONTRACTOR SHALL CONSULT AND CONFIRM WITH LOCAL PRACTICE PRIOR 3. ALL 120-V WIRING SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODE Reviewed: MR ARE To BE INSTALLED. SPACE SLEEVES 4" To 6" APART. DO NOT STACK SLEEVES 4. GROUP RCV ASSEMBLIES TOGETHER WHERE PRACTICAL, BUT AVOID GROUPING TO INSTALLATION. REQUIREMENTS. TAPE AND BUNDLE 24-V WIRE EVERY 10' AND PROVIDE LOOSE 20" LOOP VERTICALLY. MORE THAN THREE (3) STANDARD VALVE BOXES TOGETHER IN A SERIES. Date Issued: AT ALL CHANGES OF DIRECTION OVER 30 DEGREES. 5. ARRANGE GROUPED VALVE BOXES IN RECTANGULAR PATTERNS. 12.21.201E ® EMITTER SCHEDULE 14 TYPICAL TRENCHING ®TYPICAL SLEEVING 1 6 TYPICAL VALVE BOX Revision The Date City 1 Comments 2018.03.27 DETAIL DETAIL INSTALLATION 2 City Comments 2019.03.08 3 Arch Revisions 2019.06.26 4 Land Revisions 2019.09.26 5 Spa Revisions 2020.02.13 e 7 Sheet Title: IRRIGATION DETAILS Sheet Number IR3. 1