HomeMy WebLinkAboutMaster Permit.1015 Waters Ave.0204.2019 (13).ARBK HIGH EFFICIENCY CONDENSING BOILERS
K �TM
cillNIGH'
1111
WALL MOUNT BOILER
CON XUS''
REMOTE CONNECT CAPABLE
'SMARTM Al
OPERATING CONTROL FEATURING
A BUILT—IN CASCADING SEQUENCER
,t I Anilinvar
7 MODELS: 55,000 — 399,999 BTU/HR ' -
- _ r
ez<,
5:1 TURNDOWN RATIO
LESS THAN 20 ppm NOx
DIRECT VENT FLEXIBILITY TO 100 FEET 95% AFUE
h
��_�` EFFICIENCY
host Efficient LOW NOx
2015 .P� .Ce,t,,;ed
ENERGY STAR vww.energyslar.gov "et/Nt \00 r ?'pW
r ''..w:k
& IochInvar
HIGH EFFICIENCY BOILERS &WATER HEATERS
Lochinvcr.Lcm 1
TM
THE SMARTEST CHOICE FOR
KcillN G H CONDENSING BOILER PERFORMANCE
WALL MOUNT BOILER
The KNIGHT®Wall Mount, engineered with Lochinvar's exclusive SMART SYSTEMTM control and an array of other
innovative features is far ahead of any heating boiler in its class.It promises and delivers ultimate ease of installation
and maintenance.With up to 99%efficiency, low-NOx emissions and a fully modulating burner, it is the best"green choice"for today's
environmentally focused market.
Seven modulating/condensing stainless steel KNIGHT Wall Mount boilers are available with 55,000-399,999 Btu/hr inputs in a space-
saving wall-mounted design.All are equipped for direct-vent installation with air intake and exhaust runs up to 100 feet using PVC,CPVC,
Polypropylene or AL29-4C vent materials. This range of choices is ideal for residential or light-duty applications such as small hotels,
schools and office buildings. For higher-demand applications, up to eight KNIGHT Wall Mount units can be installed utilizing the built-in
cascading sequencer to deliver up to 3.2 million Btu/hr heating capacity.
The KNIGHT Wall Mount Boiler reflects Lochinvar's constant commitment to providing all the options you need to serve every application.
IIIII
40.1111110
ADVANCED NEGATIVE REGULATION TECHNOLOGY
KNIGHT safely and reliably operates with supply gas pressure as low as 4 inches water column.
_ Negative Regulation (Neg/Reg)technology automatically adjusts fan speed to ensure the correct volume
:0. and mix of fuel and air throughout the firing range.
i' FIRE TUBE DESIGN
‘ 'T // Ij This fully welded ASME Certified stainless steel heat exchanger uses oval shaped tubes to pass heat from the products
of combustion into the water stored in the vessel.To facilitate heat transfer the tubes are manufactured with dimples
1 to slow the flue products and extract available latent energy.With a fire tube design the flue products are inside
.-..,,e tapered passage ways and the water is passed through the vessel. Since the flue products pass through tubes
s and the water is circulated through a larger diameter vessel a fire tube design allows for minimal head pressure
loss through the boiler which allows the boiler to be installed easily into various hydronic applications.
`V :%`' WATER-BACKED COMBUSTION CHAMBER
�J . -, An outstanding feature of the fire tube design is a water backed combustion chamber. By having the combustion
,,,,,
fr..;
Ill
! chamber surrounded by water the Knight Wall Mount has more heating surface area.This larger heating surface
IIII . I area allows for efficiencies up to 99%.
FULLY MODULATING BURNER
I The SMART SYSTEM allows fully modulating combustion with 5:1 turndown.The burner can fire as low as 20%
vi of maximum input and modulates the firing rate up to 100%as demand increases.The burner is a single
`. ''11- : - stainless steel assembly covered with woven steel mesh and fires in a 360° pattern along the entire length
"�. 8 �� of the burner.This allows the compact KNIGHT to exceed the modulation capacities of units with larger
O multiple burners.
DIRECT VENTING UP TO 100 FEET
KNIGHT offers 5 venting options and tremendous flexibility for placement of units within the building, because it permits direct-vent air
intake and exhaust runs up to 100 equivalent feet using either PVC,CPVC,Polypropylene or AL29-4C stainless steel vent pipe.
5 FLEXIBLE VENTING OPTIONS
Direct Vent Sidewall Direct Vent Vertical Vertical w/Sidewall Air Concentric Direct Vent Vertical* Concentric Direct Vent Sidewall*
f _ .
1>
*Optional Vent Kit Sold Separately
„,�M Ifft 1 ittS£T
PMART , 1 42i , z
DNUSjTfM• 3 Ntr SCROLL
°urb o�",k. 12¢,F{118)REFINED DESIGN PUTS MORE CONTR 24 F 1.0[ 0sCE 'AND INFORMATION AT YOUR FINGERT ._ EN
sHDN 1
Advanced features include: r.frr r FI
• MULTI-COLOR GRAPHIC LCD DISPLAY � ;,a
• NAVIGATION DIAL Q' w.
• USB PORT -
• ABILITY TO CONTROL UP TO THREE DIFFERENT
SETPOINT TEMPERATURES
• COMPATIBILITY WITH COPPER-FIN II NON-CONDENSING BOILER41°11"lj-
AT-A-GLANCE CREATE A FRONT-END LOADING SYSTEM AT-A-GLANCE COLOR CODING
• BOILERS WITH DIFFERENT INPUTS CAN BE CASCADED TOGETHER -
WI
TO MAXIMIZE BOILER PLANT TURNDOWN az pe oMIRED
o°"MN
• MODBUS CAPABILITY(OPTIONAL) MENU 4MSCRE
• DHW MODULATION LIMITING G T
• DHW NIGHT SETBACK*
• 0-10 V BOILER RATE OUTPUT BLUE SCREEN YELLOW SCREEN RED SCREEN
• 0-10 V SIGNAL TO CONTROL VARIABLE SPEED BOILER PUMP* Normal system Maintenance due-shows Lockout mode.
• 0-10 V SYSTEM PUMP SIGNAL INPUT* operation. the installer's name and
• HEAT DEMAND FROM 0-10V INPUT number on the display.
• INSTALLER CAN PROGRAM NAME AND NUMBER INTO THE BOILER
• INSTALLER ADJUSTABLE FREEZE PROTECTION PARAMETERS
• SEPARATELY ADJUSTABLE SH/DHW SWITCHING TIMES* ��,
• INSTALLER ACCESS TO BMS AND RAMP DELAY SETTINGS
*EXCLUSIVE TO LOCHINVAR SMART SYSTEM C O N X us TIN
-,18818111111.8188
The CON•X•US mobile communication platform allows SMART SYSTEM
Num, to go where no other boiler has gone before:
CON•X•US provides the ability to monitor and manage multiple Knight
\ heating boilers without ever stepping into the mechanical rooms.
CON•X•US will send alerts via text or e-mail notifying of changes in
system status,and anytime,from anywhere,a user can check system
s� >2 F ww status and re-program any boiler function.Once downloaded,the free
CON•X•US mobile application allows for remote access to all SMART
SYSTEM functions using an Internet-capable device.
'CON•X US control board sold separately.
NEW SELECTABLE CASCADE OPTIONS
When multiple KNIGHT boilers are installed together, the SMART SYSTEM built-in sequencer can
be set for"Lead-Lag” cascade or"Efficiency Optimized" cascade operation.
LEAD-LAG CASCADE EFFICIENCY OPTIMIZED CASCADE
* _L_L_L I * _ _ _ _ _ _ _
11111 11111 11111
.i1II .�R. 11I -111I Ar ,ill ill .gill
The"lead"boiler modulates with demand to capacity. This feature optimizes the modulation capabilities of the
As demand increases,additional boilers fire and modulate to Boiler Plant while evenly distributing run time across all
capacity.This continues,with additional boilers firing and cascaded boilers. Every 24 hours the SMART SYSTEM
modulating to capacity until all units are operating. Every 24 automatically shifts the 1st boiler on role to the next in
hours,the SMART SYSTEM automatically shifts the lead boiler the sequence,distributing run time equally.
role to the next in the sequence,distributing lead-lag runtimes 02/07/2 019
equally. SMART SYSTEM Cascade allows 2-8 boilers to be sequenced.
KNIGHT' WALL-MOUNT BOILER DIMENSIONS AND SPECIFICATIONS
LOW VOLTAGE
ELECTRICAL
AIR CONNECTIONS
N INLET
M l�� HIGH VOLTAGE
I �� s - ELECTRICAL
L - 4; O >+00 O CONNECTIONS
RL `f, `c) CONDENSATE
FLUE 1 A fe; INLET DRAIN
RELIEF �'E- 0 J
D t 1 S<"�
VALVE UI0UJThIiKI
F G 1 11
—"tH GAS
1 ! I
B c J
TOP RIGHT BorroM
KNIGHT HEATING BOILER DIMENSIONS AND SPECIFICATIONS
Input Heating
Model Max. Min. *AFUE Capaciy Net ABCD E FGH I j K L M N 0 Gas Water Air Vent Shipping
Number MBH MBH % MBH MBH Conn.Conn. Inlet Size Wt.(lbs.)
WHN055 55 11 95.0 51 44 33-1/4"18-1/2" 16" 11-3/4" 10-1/2" 6-1/2" 4" 1-1/2" 3" 14-1/2" 5-3/4" 4" 3" 16-1/4"5" 1/2" 1" 2" 2" 139
WHN085 85 17 95.0 79 69 33-1/4"18-1/2" 16" 11-3/4" 10-1/2" 6-1/2" 4" 1-1/2" 3" 14-1/2" 5-3/4" 4" 3" 16-1/4"5" 1/2" 1" 2" 2" 142
WHN110 110 22 95.0 102 89 33-1/4"18-1/2" 19" 14-1/2" 10-3/4" 7-3/4" 7-3/4" 2-1/4" 10" 15-1/2" 5" 3-1/4"3" 16-1/2"2-3/4" 1/2" 1" 3" 3" 159
WHN155 155 31 95.0 144 125 33-1/4"18-1/2" 19" 14-1/2" 10-3/4" 7-3/4" 7-3/4" 2-1/4" 10" 15-1/2" 5" 3-1/4" 3" 16-1/2"2-3/4" 1/2" 1" 3" 3" 166
WHN199 199.9 40 95.0 185 161 33-1/4"18-1/2" 19" 141/2" 11-3/4" 8" 8" 1-1/4" 10' 16-3/4" 4-3/4" 3-1/4"2-3/4"16-1/2"3" 1/2" 1-1/4" 3" 3" 175
WHN285 285 57 95.0 264 229 33-1/4"18-1/2" 19" 14-1/2" 11-3/4" 8" 8" 1-1/4" 10' 16-3/4" 4-3/4" 3-1/4" 2-3/4"16-1/2"3" 1/2" 1-1/4" 3" 3" 184
WHN399 399 80 94.4 377 328 35-1/2"25" 21-3/4"17-1/2" 12-1/2" 9-1/4" 9-1/2" 2-1/4" 13-1/4" 21-1/2" 9" 43/4"4" 22-1/2"3-3/4" 3/4" 1-1/2" 4" 4" 213
Notes:Indoor installation only.All information subject to change.Change"N"to"L"for LP gas models.*WHN399 value is Thermal Efficiency
SMART SYSTEM- FEATURES STANDARD FEATURES
>SMART SYSTEM Digital Operating Control >Access to BMS Settings through Graphic >ENERGY STAR Most Efficient Recognition5
LCD Display
Multi-Color Graphic LCD Display 95%DOE AFUE Efficiency5
Dial and Soft Ke s >High-Voltage Terminal Strip
with Navigation
y Modulating Burner with 5:1 Turndown
>Three Boiler Set point Temperature Inputs 120 VAC/60 Hertz/1 Phase Power Supply
P P P Direct-Spark Ignition
Plus Domestic Hot Water Prioritization Three Sets of Pump Contacts
>Low Voltage Terminal Strip Low-NOx Operation
>Built-in Cascading Sequencer for Field Convertible from Natural to LP Gas
up to 8 Boilers 24 VAC Device Relay
Multiple Size Boiler Cascade Proving Switch Contacts >ASME Stainless Steel Heat Exchanger
Lead Lag Flow Switch Contacts 30 psi ASME Relief Valve
Efficiency Optimization Alarm on Any Failure Contacts >Vertical&Horizontal Direct-Vent
CPFront End Loading Capability with Copper Fin II Runtime Contacts PVC,eet Polypropylene or SS Venting up to
>Outdoor Reset Control with Outdoor DHW Thermostat Contacts 100 feet
Air Sensor 3 Space Heat Thermostat Contacts >Smart System Control
Programmable for Three Reset System Sensor Contacts >Condensate Trap
Temperature Inputs DHW Tank Sensor Contacts >Other Features
>Programmable System Efficiency Optimizers Outdoor Air Sensor Contacts Automatic Reset High Limit
Night Setback Cascade Contacts Adjustable High Limit w/Manual Reset
DHW Night Setback* 0-10 VDC BMS External Control Contact Boiler Circulating Pump
Anti-Cycling 0-10 VDC Boiler Rate Output Contacts Wall-Mount Bracket
Outdoor Air Reset Curve 0-10 VDC Variable Speed System Pump Signal Zero Clearances to Combustible Materials
Input* 12-Year Limited Warranty
Ramp Delay
Boost Temperature&Time 0-10 VDC Signal to ontrol Variable (SeeeaWPartsty fora Details)
PSpeed Boiler Pump* y
>Three Pump Control Modbus Contacts OPTIONAL EQUIPMENT
System Pump with Parameter for >Time Clock CON-X-US Remote Connectivity
Continuous Operation >Data Logging Modbus Communication
Boiler Pump with Variable Speed Hours Running,SpaceHeatingFlow Switch
Pump Control* Low-Water Cutoff w Manual Reset&Test
Domestic Hot Water Pump Hours Running,Domestic Hot Water /
Ignition Attempts Alarm Bell
>Domestic Hot Water Prioritization Last 10 Lockouts Concentric Vent Kit
DHW tank piped with priority in >Maintenance Reminder SMART SYSTEM PC Software
the boiler loop Condensate Neutralization Kit
DHW tank piped as a zone in the Custom Maintenance Reminder with Contractor
p p Contact Information BMS Gateway to LON or BacNet
system with the pumps controlled
by the Smart System Installer Ability to De-activate Multi-Temperature Loop Control
DHW Modulation Limiting Service Reminder Sidewall Vent Termination
Separately Adjustable Space Heat/DHW Low-Water Flow Safety Control&Indication Floor Stand
Switching Times* Password Security Wireless Outdoor Sensor
>Building Management System Integration Customizable Freeze Protection Parameters FIRING CODES
0-10 VDC Input to Control Modulation >M9 Standard Construction
or Set Point >M7 California Code
0-10 VDC Modulation Rate Output *Exclusive feature,available only fr
0-10 VDC Input to Enable/Disable call for heat §WHN 55-285 only el
C I
Lochinvar,LLC Patent Pending
O1. P:615.889.8900/F:615.547.3000 AMR: ( ----0
s- 300 Maddox Simpson Parkway
Lebanon,Tennessee 37090 r�Most Efficient ���
f.37.,
.+... CERTIFIED.IGH EFFICIENCY BOILERS&WATER HEATERS el El MI 0 LOChinVar.cnm ��..•.....,,.�..:- cal,ieo® CO,, <,®
WHN-04 (Reprint WHN-o4 5/15) PDP-2.5M-9/15-Printed in U.S.A.