Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Master Permit.1015 Waters Ave.0204.2019 (16).ARBK
Sauire® StabrieddSeed 1od'vzect Vaterz geatetz _ *` - a new Class of Water Heater The Squire Stainless Steel Indirect Water Heater--with 12 models to choose from in capacities from 30-119 gallons, we are sure to have the right size indirect water heater to fit your application. Squire features important enhancements that our customers will recognize and benefit from such as a welded and passivated stainless steel tank and heat t exchanger, two-inch thick, high-density insulating foam, and best of all it is designed, engineered and assembled in America. ~— Stainless Steel Tank Manufacturing Laser Cut Precision 4.l_ A CNC laser uses Programmable Logic Controls to precisely cut the Squire Indirect Water \ - Heater's tank shell out of 14 gauge 316L stainless steel to a tolerance of.01 inch. — — . ' .1 Tank Cylinder Roller The computer controlled tank cylinder rolling machine ensures that the 316L stainless steel is transformed into a geometrically perfect cylinder. Coil Winder Straight tubes are rolled by a seven axis coil winder and turned into a precise,round LASER Cut Precision coil used in the indirect water heater to transfer the BTU's from the heat source to the potable water stored in the tank. Robotic Welder � --g,� P, . This state of the art six axis programmable robotic welder uses computer guidance to 9• )4"e.;i' AM accurately weld the stainless steel fittings to the tank. `;40 �° -� Hydrostatic Leak Test i n - After welding,the tank is hydrostatically pressure tested to ensure quality '� - - conformance. Passivation Process I Each tank is subjected to a soaking spray of r.--- f} t _ r I �-- nitric acid.This treatment washes away any �' � �r•^ ' _ _1 I . iron that was left behind during the welding process and re-establishes the oxide level of the .` stainless steel to ensure corrosion resistance.� Robotic Welder By removing iron from the welded surfaces,the l Squire is less susceptible to corrosion brought ' tt •• r. ! I on by aggressive water. U i Jacket and Foam ro iiit. •, — .E ' The dent resistant polypropylene jacket and I" 4- 444,41 ' 1 40 ' ABS caps are attached to the tank assembly, - ."_ _ ._. ,.....- , a: = and then high density foam is added using a '``- t.: high pressure dispensing system to provide +., i insulation that will keep the heat where it • C- . .1) f ," belongs, in the water.The result is a tank that =' `� ,.. is jacketed and evenly foam insulated with , Passivated for Protection standby losses as low as 0.5°F per hour. Foam Insulation Fe6kVs97/2 2 11rASPEN BUILDING DEPARTMENT Outstanding Features - - Six Standard Models from 30 to 119 Gallons 316E Passivated Stainless Steel Tank The highest quality indirect water heater in the market also has 316L Stainless Steel material is used for the tank interior for one of the widest ranges of gallon capacities. With 6 models superior durability and long life. The rust prohibitive characteristics covering gallon capacities from 30 to 119 gallons the Squire is of this material make it the perfect material to resist the corrosive one of the broadest lines available. tendencies of domestic water. The passivation process consists of a treatment method that enhances and increases the superior Six Solar Models from 65 to 119 Gallons corrosion resistance of stainless steel. With three dual coil models for solar heating in conjunction with a heat source and three models with a solar coil and an electric 316E High Capacity Stainless Steel Coil element the Squire line of water heaters has a model to fit any The Squire's 316L Stainless Steel heating coil efficiently transfers high residential or light duty commercial solar application. volumes of BTU's from the heat source to the domestic water with high first hour delivery capability. 100%Stainless Steel Construction Squire Water Heaters are constructed with Stainless Steel Designed, Engineered and Assembled in the USA materials that are highly resistant to corrosion that can result A 100%stainless steel indirect water heater built in the USA, from poor water quality. the Squire is completely assembled in Lebanon, Tennessee. 1. Inside Look How it Works Dent resistant polypropelene jacket* Temperature Stainless Steel SIT Indirect ,, &pressure The Squire uses the power and efficiency of the relief valve building's heating boiler or solar array to generate domestic hot water for showers, dishwashing, clothes Boiler Sensor washing or any potable hot water demand. The water inlet well efficiency of the heating boiler could be as much as 20% higher than a direct-fired tank-type water heater. So,why 316E not use that efficiency to "indirectly" provide hot water for ( Stainless all potable applications? `b,s Steel coil By using the Squire to indirectly heat the domestic water,you Boiler water eliminate the additional gas line,electrical connections and vent ducts needed with direct-fired tank-type water heaters. outlet High density foam insulation it Cold water , inlet -------- 06.1110„ *SET models feature metal jacket 91J.I ' 2 lir : - d' 41.711: 1 - r ,, 1c 7 - , ',C III __ Combine the Knig` Heating Boiler with the ' , Eta Squire Indirect the perfect combination for ' your applic n. 02/07/2019 3 IF ASPEN miill BUILDING DEPARTMENT Fully Welded Construction T&P Relief Valve Lochinvar utilizes state of the art, highly accurate robotic Supplied with the unit in the carton. (shipped loose) welding equipment that results in a fully welded construction method that requires no gaskets or mechanical sealing High Density CFC/HCFC Free Polyurethane Foam methods. Gaskets and seals are the weak point of any water Two inches of R-13.4 High Density Polyurethane foam yields storing appliance, therefore Lochinvar's advanced design the lowest standby losses in the industry. eliminates this potential failure point. Attractive Rust Resistant Jacket Factory Supplied Tank Sensor (SIT and SDT only) Resistant to scratches and dents, the Squire will maintain its A tank sensor with built in temperature limit is standard classic high quality appearance for years. equipment on all sizes. This sensor accurately monitors the water temperature and sends a call for heat when the tank Limited Lifetime Warranty* temperature drops below the desired setpoint. This sensor Lochinvar believes that the Squire is the best built Indirect is 100%compatible and can be directly connected with Water Heater on the market, we have a Limited Lifetime Lochinvar's line of KNIGHT or Cadet Heating Boilers. warranty to prove it. *SIT models only Solar Indirect with SDT Dual Coil Solar Indirect with SET Electric Back-up Squire Indirect Water Heaters with a dual coil design Squire Indirect Water Heaters with a single coil and have a coil in the lower portion of the tank to transfer an electric element are designed to collect heat from heat from a solar array to the water that is stored in a solar array and transfer the collected heat into the tank. the stored water by way of the indirect coil which is located in the lower portion of the tank. An additional coil in the upper portion of the tank will transfer heat from a back-up boiler into the An electric element,which is controlled by a factory water. This will ensure that the tank has ample hot supplied thermostat, is positioned in the top half of water even at times when the solar array cannot the tank to ensure ample hot water even at times generate enough heat to suitably heat the tank. when the solar array is not capable of collecting the heat required by the DHW demand. tiliTilliiiir 1-41 cat illitli tu 1. 01-4' f , , ,. F i EIVE 02/07/2019 ASPEN BUILDING DEPARTMENT Stainless Steel Indirect SIT Models Dimensions and Specifications B 1 HOT WATER 4"� OUTLET i RELIEF VALVE r (shipped loose) A BOILER 225=\ IN 11 s 45° D \ SENSOR WELL G BOILER �'�OUT The"Hot Water Outlet"connection is Female NPT. H I 0 All other connections are Male NPT.COLD WATER INLET Domestic Coil Model Water Connection Shipping Number A B D G H I Conn. Size Wt. (lbs.) SIT030 39-1/2" 20" 32-1/4" 21-3/4" 8-1/4" 3" 1" 1" 79 SIT040 55-3/4" 20" 48-1/2" 25-1/4" 8-1/4" 3" 1" 1" 105 SIT050 48" 24" 39-3/4" 24-1/2" 9-1/4" 3-3/4" 1" 1" 131 SIT065 60" 24" 52-1/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 147 SIT080 69-1/2" 24" 61-3/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 177 SIT119 69" 28" 60-1/4" 31-3/4" 9-1/4" 3-1/4" 1-1/2" 1" 213 Heat Source Standby First Continuous 1st Hour Min. Flow Friction Model Capacity Water Volume Loss Draw Delivery Delivery Coil Load Rate Loss Number (Gallons) (Gallons) (°F/Hr) Gals. (GPH) (Gallons) (Btu/Hr) (GPM) (Ft. Hd.) SIT030 27 1.1 1.5 24 160 184 99,000 14.0 3.9 SIT040 40 1.6 0.9 27 181 208 115,000 14.0 4.5 SIT050 52 1.7 0.9 45 210 255 133,000 14.0 5.3 SIT065 67 1.9 0.7 65 263 328 154,000 14.0 5.7 SIT080 82 2.1 0.6 74 266 340 160,000 14.0 5.7 SIT119 113 3.2 0.5 109 308 418 199,999 14.0 6.5 Performance data is based on IWH-TSI test results.All ratings are based on 180°F boiler water temperature with incoming cold water at 58°F and a Delta T of 77°E Includes tank sensor for use with KNIGHT or Cadet Heating Boiler. Optional thermostat available for use with other boiler models. SIT MODELS All models standard with a Lifetime Limited Warranty Against Tank Failure. All parts are warranted for one year. Five year limited tank warranty on all $up o models when installed in a commercial ram CERTIFIED,. --C4® application. C US `( NTE �� 1 02/07/201 ASPEN BUILDING DEPARTM Solar Stainless Steel Indirect Dimensions and Specifications B 'CV0 HOT WATER FROM HOT WATER OUTLETILER OUTLET BOILER GI = 0 RELIEF VALVE SENSOR A (sM1ipped loose) WELL RELIEF VALVE TO (shipped loose) d� -22.5°45° x Le BOILER / 22.5°\ . 45° A FROM A FROMPANEL DrPANEL D E SOLAR SOLAR SENSOR SDT Models F SENSOR SET Models WELL G G TO TO PANEL 1 /PANEL H � HI t I I t I t t ` I t COLD WATER f COLD WATER INLET The"Hot Water Outlet"connection is Female NPT. INLET SDT Models Dimensions and Specifications All other connections are Male NPT. Domestic Coil Model Water Connection Shipping Number A B D E F G H I Conn. Size Wt. (lbs.) SDT065 60" 24" 52-1/4" 47-1/4" 33-3/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 158 SDT080 69-1/4" 24" 61-3/4" 53-3/4" 40-1/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 188 SDT119 68" 28" 60-1/4" 54-1/2" 37-1/2" 31-3/4" 9-1/4" 3-1/4" 1-1/2" 1" 224 Heat Boiler Heat Standby Continuous 1st Hour Min. Flow Friction Model Capacity Source Water Source Water Loss Delivery Delivery Coil Load Rate Loss Number (Gallons) (Gallons) (Gallons) (°F/Hr) (GPH) (Gallons) (Btu/Hr) (GPM) (Ft. Hd.) SDT065 66 2.1 1.7 0.7 175 205 128,000 14.0 3.4 SDT080 79 2.1 1.7 0.6 175 208 128,000 14.0 3.4 SDT119 110 3.2 2.6 0.5 251 301 181,000 14.0 4.9 Performance data based on incoming cold water at 50°F and a Delta T of 77°E Delivery ratings for boiler coil only.Includes tank sensor for use w/KNIGHT Heating Boiler. SET Models Dimensions and Specifications Domestic Coil Model Water Connection Shipping Number A B D G H I Conn. Size Wt.(lbs.) SET065 60" 24" 52-1/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 149 SET080 69-1/2" 24" 61-3/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 179 SET119 68-1/4" 28" 60-1/4" 31-3/4" 9-1/4" 3-1/4" 1-1/2" 1" 215 Electric Electric Heat Source Standby Continuous 1st Hour SET&SDT MODELS Model Capacity Water Loss Delivery Delivery All models standard with a 5 year Number (Gallons) (Gallons) (°F/Hr) (GPH) (Gallons) Limited Warranty Against Tank Failure. All parts are warranted for one year. SET065 67 1.9 0.7 24 54 SET080 81 2.1 0.6 24 57 SET119 113 3.2 0.5 24 75 All SET models:4500w 240v 1 phase. 1 ® _ Oa Lochinvar,LLC e)' ��CEI NI I ;j-. 300 Maddox Simpson Parkway �� ��o �7�.AN '—�� Lebanon,Tennessee 37090 ® 0 2/0 / '1 LL ✓ P:615.889.8900/F:615.547.1000 HIGH EFFICIENCY BOILERS&WATER HEATERS C US *SET models onlyLOW LEAD ©®0 Lochinvar.com CONTENT SIT-02(Reprint SIT-02 10/15) (Website Update 9/16 PDP-10M-5/16—Printed in li.$A.