Loading...
HomeMy WebLinkAboutMaster Permit.1015 Waters Ave.0204.2019 (40).ARBK 0076-2018-ARBK_BuildingCommentl A-Architecture.101 5Waters.201 8-4.pdf(47) Subject: PlanCheck ✓ . '� I - Page Label: 1700-V FIREAREACALCULATIONS You do not need to include the 1 ' � thickness of the exterior walls in . Author:justinh -- I .ii:1 u I- File Name: A-Architecture.1015Waters.2018-4.pdf your fire area measurements, this number should be the same °u,a as your gross building area in - LL TOTAL FRE AREA SA8°EOfT A-003 Gross Area& Fire Area has been combined. this instance. a�l roj a Subject: PlanCheck✓ The entire area under the Page Label: 1700-V FIREAREACALCULATIONS Author:justinh carport projection counts UPPER LEVEL FIRE AREA`A"UL towards gross and fire area, File Name: A-Architecture.1015Waters.2018-4.pdf IN �` please revise both drawings ' 1owt ,' ' ' ` A-003 Gross Area&Fire Area has been combined. accordingly. tti-elKitiaiSii � a - Subject: PlanCheck ✓ Page Label: A-002 SNOWMELT PLAN &DETAILS Please fill out the 2015 IECC I iiiiiiij` �""' Author:justinh REMP worksheet(attached),this _ M _u_ File Name: A-Architecture.1015Waters.2018-4.pdf form is outdated. A new updated REMP form has been updated to 2015,and is attached on A-002 and and ET- in Documents#31 Round 1. A `PaR ' r i j Subject: PlanCheck ✓ __ = Page Label:A-002 SNOWMELT PLAN &DETAILS Provide an accurate scale for Author:justinh this sheet, none of the drawings 13 SOFT. measure correctly at the 1/4" File Name:A-Architecture.1015Waters.2018-4.pdf scale you've called out. It a.v., 1015 WATERS AVE. appears to be 3/16"scale. SNOLLMELT DIAGRAM A-002 Snowmelt Diagram has been updated and with a corrected scale of 3/16"= 1'-0"and scaled. i G°°; Subject: PlanCheck✓ Page Label:A-100 LOWER LEVEL•50FLOOR PLAN Are these partitions and/or O BT ® L� • © I s,° pocket doors to create a • @t r°"° Author:justinh a, separate enclosure for the toilet? �a File Name:A-Architecture.1015Waters.2018-4.pdf O : • If so, please revise the ","" MEe There is only one partition of glass at the Master Bath and mechanical plan to show bath °=„owo exhaust in the main shower/sink -_ - sue„ Bath 3-009. C) "° rooms in addition to the ones I,. An additional exhaust fan will be added to the Bathroom 009 T°k'^° i shown above the toilets. When : = � o along with the exhaust fan in the Master Bath area. Li , Cart toilets are placed in separate enclosures they require their own exhaust so the,shgwer \ ,.' would require it's own exhausf,ir�' ' 0+.r this scenario. Please make change in all applill®ctipr 19 on all levels. // // ASPEN BUILDING DEPARTMENT a , Subject: PlanCheck ✓ rg ,��La,r,� T.O. Slab is inconsistantly Page Label:A-101 MAIN ENTRY LEVEI.50FLOOR PLAN O_Ij a:LE g shown in the various plan sets, r m,� Author:justinh some show it is 100'-0", others File Name:A-Architecture.1015Waters.2018-4.pdf show it as 99'-5"if +1 a �. Garage slabs have been coordinated on all pertinent sheets 7960.0'=100' 0"as you site plan -- and resubmitted. shows. Coordinate these 7 IT elevations throughout all plan 1 0 —@ sets. '" I— aa.- ks I mi Subject: PlanCheck ✓ Page Label:A-101 MAIN ENTRY LEVEI.50FLOOR PLAN This should note should be � j down, not up. M�;1•.F„ _,sm �Ird Author:justinh III LOPLE99;—IJ= File Name: A Architecture.1015Waters.2018 4.pdf �IIIII� %__ .,........, The note has been corrected and pertinent sheets have been re-submitted. I © e I -- imilmEl Subject: PlanCheck ✓ Page Label:A-101 MAIN ENTRY LEVEI.50FLOOR PLAN Show your electrical panel Author:justinh location on the floor plans File Name: A-Architecture.1015Waters.2018-4.pdf Show your electrical panel location on the floor plans The Elec. panels are in the Lower Level Mech. Room 1 and shown. iP1.111111_. " Subject: PlanCheck ✓ Page references are incorrect, I® �I 77 Page Label:A-101 MAIN ENTRY LEVEI.50FLOOR PLAN Please revises ons allr sheets. A� Author:justinh 11. II, 0I'o',v m_ File Name:A-Architecture.1015Waters.2018-4.pdf kid7,' II 1 I The page references have been corrected on all floor plans/elevations and sections and re- , lil submitted. TIm—..-- n Subject: PlanCheck 4 1 Page Label: A-102 UPPER LEVEL•50FLOOR PLAN The maximum riser height Author:justinh allowed by the IRC is 7-3/4", File Name: A-Architecture.1015Waters.2018-4.pdf please revise. The maximum riser The riser heights have been revised to 6-7/8"on all interior stairs. All pertinent sheets have height allowed by the -----IRC is7-3/4",please - been re-submitted. revise 16 Zi- ,. ,12" RECEIVED 02/07/2019 ASPEN BUILDING DEPARTMENT Subject: PlanCheck ✓ Page Label:A-103 ROOF& ROOF DEC•50PLAN What is this note referencing? hE5iiiiiii= Author:justinh :, File Name:A-Architecture.1015Waters.2018-4.pdf PANGOThis note is referencing an upper window. Since the building has been re-designed,that window "°"' 1 •IIIIInnnni is now Window C.1 and can bee seen on the East Elevation. _Ir-- 6 I ____i III, tit I - I Subject: PlanCheck, Page Label:A-103 ROOF& ROOF DEC•50PLAN Identify the location of the Author:justinh secondary drain discharge on a Identify the location of the floor plan or elevation. IPC1108 secondary drain discharge on a I I File Name:A-Architecture.1015Waters.2018-4.pdf floor plan or elevation. IPC 1108 requires secondary roof requires secondary roof I I The secondary discharge for the roof drain is drainage to discharge above drainage to discharge above I '^ grade in a conspicuous location identified on A-202 West Elevation and A-204 East grade in a conspicuous location that would normally be observed I Elevation. by the building occupant. that would normally be observed I I by the building occupant. — — — I I 11. Subject: PlanCheck/ hec k✓ a 11 Page Label:A-103 ROOF& ROOF DEC•50PLAN Show and identify all proposed Author:justinh exhaust/venting. Currently I only File Name: A-Architecture.1015Waters.2018-4.pdf see the fireplace venting shown. Show and identify all proposed exhaust/venting.Currently I only see the Exhaust and venting has been identified on the Elevation Sheets A-201 thru A-204 and the Roof fireplace venting shown. Plan. 1;1 1 JIIIII m. t ` `I Subject: PlanCheck ✓ L -IL— •.—_— o i is Page Label:A-103 ROOF& ROOF DEC•50PLAN Snowguards should be provided ' a. Author:justinh here as it is above an occupied File Name:A-Architecture.1015Waters.2018-4.pdf deck. .41.... 1©� Snowguards have been added to the roof. Ian rail I ' 1 O FLAT BUILT UP ROOF/METAL F. Subject: PlanCheck ✓ 11 ® FLAT SEAM METAL ROOF Page Label: A-201 NORTH ELEVATION #15 is not an item on the 9❑ 4"METAL FASCIA TRIM Author:justinh keynote legend, please revise. 15 10 SNOW GUARD PER R903.6 III CHIMNE PROJECTION<,G FR File Name: A-Architecture.1015Waters.2018-4.pdf BUILDING CONNECTION PER 2E O 1 The# 15 has been removed from the note. o #15 is not an item on a the keynote legend, please revise. TO PLATE:EL,120'-1 I/2+ RECEIVED 02/07/2019 ASPEN BUILDING DEPARTMENT O J� © Subject: PlanCheck ✓ What is shown here? It is not Page Label:A-201 NORTH ELEVATION II Author:justinh identified by any keynote and it IIIl6irninlnIII File Name:A-Architecture.1015Waters.2018-4.pdf does not correspond with anything shown on the floor plans. This is a smooth stone veneer material. Subject: PlanCheck ✓ Page Label:A-201 NORTH ELEVATION Show all venting, intakes, and ' Author:justinh exhaust terminations on your File Name: A-Architecture.1015Waters.2018-4.pdf elevations so that I may verify sneWal a akee a de.na a,term; s r required clearances from yea,eleat;ea ao that may a„rv,a4,ed elea,aa�� from epen;n9a Into the!Adding,etc.I'm seeing multiple openings into the building, etc. Items in the mechanical plans that are not shown. I'm seeing multiple items in the VERSAmechanical plans that are not METAL ROOF OVER 2 LAT.RS MELD re shown. INTERIORr.t."`' Exhaust and venting has been identified on the Elevation Sheets A-201 thru A-204 and tghe Roof Plan. 1 m I LY I V Subject: PlanCheck 2ll� 1 9l!IIIIIIIIIIIIIII What are you showing with —�I-� Page Label:A 202 EASTELEVATION ■ i_m f� these breaks in your shading? I.. . �Wi Author:justinh z.�m�� _MINim File Name: A-Architecture.1015Waters.2018-4.pdf I� _ MIImrTIV■ U011llllliillll!!!IIIIIIIIII���_ These no longer exist and were previously a mistake. 1j1+ Il F Subject: PlanCheck✓ Page Label:A-202 EASTELEVATION #15 is not referenced in your © O Author:justinh keynote legend, please revise. File Name: A-Architecture.1015Waters.2018-4.pdf The# 15 has been removed from the note. 15 Subject: PlanCheck ✓ Page Label: A-202 EASTELEVATION #13 is not referenced in your Author:justinh keynote legend, please revise. 8 File Name: A-Architecture.1015Waters.2018-4.pdf #13 is not referenced inn your keynote legend,please revise. The# 13 has been removed from the note. T.O.PLATE E RECEIVED 02/07/2019 ASPEN BUILDING DEPARTMENT — Subject: PlanCheck✓ Provide a wall section showing Prwmeawan servos showing now you well accomplish me Page Label:A-301 BLDG. SECTIONA-A Author:justinh how you will accomplish the air °d sealing requirements of 2015 IECC table P452J4.1. sealing requirements of 2015 icateme°°^°^°"yntt^eair^amen^°wM1ere^ie File Name:A-Architecture.1015Waters.2018-4.pdf locatetl M1reugM1out IM1e builtling.Note locations IM1at require g.=ealag.api"g. atlar,io=,ioasbe„e,etl_erent IECC table R402.4.1.1. Indicate the continuity of the air barrier ana inspaoror m be anasessrnl.mesa aetail:are a new 2ot5 r is a requirement now mat visual in test Sn of me air bane,iaregaipiesofeiMa blower tails You use and where it is located attached examples of air sealing Oatails.You may use any l� memos°"em"nag°"nt mem°tletaaanmpllsM1 mia throughout the building. Note requirement but a congnuous sir Berner must be clearly M1�w Response:A sealing detail reference has been locations that require caulking, 10. ,K.F�R ��m-,, added to the construction documents for sealing,taping, etc at transitions guidance to the contractor. See A-604 Round 1. between different materials (such as wall to foundation,wall to roof, etc). The better detail provided the easier it will be for the contractor and inspector to be successful. These details are a new 2015 code requirement now that visual inspection of the air barrier is required in lieu of a blower door test. See the attached examples of air sealing details. You may use any method or combination of methods to accomplish this requirement but a continuous air barrier must be clearly shown. Subject: PlanCheck ✓ Page Label:A-301 BLDG. SECTIONA-A Your radon pipe and foundation Author:justinh drain are reversed, please File Name:A-Architecture.1015Waters.2018-4. df revise. TO.PR CANCEL:ST-4 3•0 p .FIN CONCH:9G4 Corrected. Subject: PlanCheck ✓ Page Label:A-301 BLDG. SECTIONA-A The majority of detail references Author:justinh on this sheet are incorrect, File Name:A-Architecture1015Waters2018-4.pdf please go through all your detail . . The majority of detail references tags and be sure they are on this sheet are incorrect,please go through all your detail tags and All details references have been corrrected. referencing the correct be sure they are referencing the .assembl correct assembly. y T.O.PLATE EL. 128'-8 3/8" 126-83en Subject: PlanCheck ✓ r Page Label:A-301 BLDG. SECTIONA-A This detail is not provided, Author:justinh please do so. File Name: A-Architecture.1015Waters.2018-4.pdf pro ded Iplease do The detail notes have been corrected. 7 � II� RECEIVED 02/07/2019 ASPEN BUILDING DEPARTMENT —�� Subject: PlanCheck✓ .� __ Page Label:A-302 BLDG. SECTIONB-B This note is incorrect,this would I.MI_ Author:justinh be required to be insulated as a _R,LEWL1194 , ceiling not a floor over exterior File Name:A-Architecture.1015Waters.2018-4.pdf 1 �� 1, space. Revise your note and ;III El reference the applicable detail. o The insulation notes have been correced on the Building I I TA.EN RR EL:9B'4D '. ",,, Sections. _�— Subject: PlanCheck✓ Provide details for the garage Page Label:A-302 BLDG. SECTIONB-B dikl E21111111 Author:justinhceiling and walls that show --Surd File Name:A-Architecture.1015Waters.2018-4.pdf compliant dwelling garage 111 separation per R302.6. � I� The Garage walls have been noted Reference these details on ��= for compliant dwelling-garage sections BB and CC as �o_ _ _ applicable. -- separation OBUILDING SECTION B-B SCALE:1/4".1'-0" Subject: PlanCheck `/ Page Label:A-302 BLDG. SECTIONB-B Provide a detail showing stone Author:justinh veneer anchorage,flashing and File Name: A-Architecture.1015Waters.2018-4.pdf weepholes per 2015 IRC R703.8.2, R703.8.5 and 'W� "`" See Detail 3/501 for Stone veneer anchorage flashing and R703.8.6 weep holes@ veneer stone panels. „* I 0 o M Subject: PlanCheck ✓ Page Label:A-302 BLDG. SECTIONB-B Please reference applicable Author:justinh floor, roof, and wall details in T File Name:A-Architecture.1015Waters.2018-4.pdf sections BB, CC, and DD similar to what you have done shown in Details referencing the roof wall and foundation on the AA. Very few detail tags are .ea a".v°"are"ere"eame m°�:rea aeu,n.as ream w u»' building sections has been added and corrected. provided in the last 3 sections. Be sure you are referencing the correct details as many of the ones shown are incorrectly referenced currently. o O Subject: PlanCheck✓ Is this a range hood? The mi. , .. ..4. Page Label: A-303 BLDG. SEC.C-C Author:justinh mechanical plan does not show w File Name: A-Architecture.1015Waters.2018-4.pdf any range hood provided. 1 Revise one or the other for a consistency or clarify what is Tniirill The range hood has been identified on the Sections shown here. ! E as a Recirculating Hood.The specifications has been added to the Documents:#34. RECEIVED 02/07/2019 ASPEN BUILDING DEPARTMENT T.O. w.FLR EL:II -a° Subject: PlanCheck ✓ — — Incorrect reference for the —==E�a,a. Page Label:A-304 BLDG. SECTIOND-D Author:justinh handrail detail, please revise. Incorrect reference for File Name:A-Architecture.1015Waters.2018-4.pdf e handrail detail• please revise. am The reference has been corrected. . T.O.FIN.FLR EL.:I0O-m Subject: PlanCheck.I Remove this note from all plans, Page Label:A-304 BLDG. SECTIOND-D Author:justinh you are not actually proposing a q,FK a.10a ^ File Name:A-Architecture.1015Waters.2018-4.pdf 1 hour wall. ______---- The 1 hour notes have been removed. Subject: PlanCheck ✓ Show or note the requirement for Page Label:A-401 EXTERIOR STAIRS guards along the open sides of O.FIN.FLREL.:10-31'' Author:justinh stairs to restrict the passage of I I File Name: A-Architecture.1015Waters.2018-4.pdf a 6"sphere at the opening Show or note the formed between the guard and requirement for guards F The railing on the Interior and Exterior Stairs are enclosed along the open sides of stairs to restrict the to the steps. stair tread/riser. paase goe ofn igomee SOUTH ELEVA' between the guard and SCALE: 3/811 - tair tread/riser. - Subject: PlanCheck ✓ ___ ° `�� This exceeds maximum allowed � Page Label:A-401 EXTERIOR STAIRS ��li������ t Author:justinh riser height, please revise. 1® ;ll 55 File Name:A-Architecture.1015Waters.2018-4.pdf III y� Mal 8 SCALE IOPOTAI OPL wll The exterior stairs and design has been revised. rHi w., T Asper Subject: PlanCheck ✓ OTS • Page Label: A-401 EXTERIOR STAIRS Guards must limit the passage of M M---� Pare' a 4"sphere, a 4"opening does ;-- Author:justinh �re.n'e File Name: A-Architecture.1015Waters.2018-4.pdf not comply with that. Please :_� ■ 0 revise to show compliance with :ISM SUIRVE E_= o:9]o-s TURTLE The Guards have been revised to 3-1/2" R312.1.3 ua•amuat lim TUTRE ii_iy� pa::reeaaf o6"p ela 1=�n enin Ge Glemvo I M=1 •oa:viea.,1,..t ore]a ahowmmgiencewim CHILE ,4„�A 28 I.-■ a3t2.t.3 0.20l er Gi —DIM Glenwoi 0:9]0-9 RECEIVED 02/07/2019 ASPEN BUILDING DEPARTMENT Subject: PlanCheck ✓ Page Label:A-401 EXTERIOR STAIRS If you are using keynote Author:justinh numbers to reference items then File Name:A-Architecture.1015Waters.2018-4.pdf you must provide a legend on the applicable sheets. C0N 1'i0 1,6.1R "LL.- FIR RR=1n The notes have been revised. 0111 LD.MRREL In'-1�' in iD.LN1DMG EL l0LAIMG El:113 Subject: PlanCheck ✓ Page Label:A-402 INTERIOR STAIRS Dimension this opening in your guardrail at the landing to show Author:justinh compliance with the opening om°°=°nlhla File Name:A-Architecture.1015Waters.2018-4.pdf a°^ ^r°° limitations of R312.1.3. '/,• am snow I°^mnopeningations The design of the railing has been revised and is now closed to the stairs. I opening Mutations R312.1.3. 14. STAIRS 018 Subject: PlanCheck ✓ t■II'i, Handrails shall return to walls or Page Label:A-402 INTERIOR STAIRS Author:justinh shall terminate in newel posts or WNW— safety terminals. Please revise m- IFile Name: A-Architecture.1015Waters.2018-4.pdf all stair plans/details or show The Handrails are terminating into the walls. more detail to demonstrate compliance with R311.7.8.2. wiIIII! Subject: PlanCheck ✓ Page Label:A-403 GAS APPLIANCE•50PLAN &SPECS On the fireplace registration form &ELEVATIONS you marked that 3 new DV Author:justinh fireplaces were being installed. On the fireplace registration form you marked, File Name: A-Architecture.1015Waters.2018-4.pdf Please submit a revised form that 3 new DV fireplaces were being installed. Please submit a revised. A new Fireplace Registration form has been filed out correctly. See Document#8 Round 1. GAS AP DA VINC -)nit TAi Subject: PlanCheck ✓ Page Label: A-501 ARCHITECTURALDETAILS Please remove this note as it Author:justinh does not apply to your exterior File Name: A-Architecture.1015Waters.2018-4.pdf wall. aoav Iro:;"° rs7Fir. The details has been revised. O EXX1ERIOR WALL a SIDIN( iow IILJIf°.�oE I RECEIVED 02/07/2019 ASPEN BUILDING DEPARTMENT ®Fo,,o4TICN(T,PICAL/ -'-`--- Subject: PlanCheck ✓ Please remove this note from all Please remove a Page Label:A-501 ARCHITECTURALDETAILS note from all Author:justinh applicable details as it does not does"nolpadan'toths pertain to this project and it project and it - File Name:A-Architecture.1O15Waters.2018-4.pdf references a code references a code edition we ' edition we have never XX: adopted. have never adopted. WM: The details have been revised. a.M o n INNTTERIIOR.WALL TYPICAL )-LW 11- HT- Subject: PlanCheck ✓ Page Label:A-501 ARCHITECTURALDETAILS Please remove all references to I Author:justinh listed/tested assemblies. None File Name: A-Architecture.1O15Waters.2018-4.pdf of your assemblies require fire ratings or sound ratings. s - The details have been revised. ir•Oi IS 0TYPA ICL INT.WALL BASE I Subject: PlanCheck ✓ �� ° Provide documentation that your s Page Label:A-501 ARCHITECTURALDETAILS roof assembly is class A(ESR ww Author:justinh report, UL listing, etc.) . .Fz „ File Name: A-Architecture.1O15Waters.2018-4.pdf o...u. This document was already submitted with the first Permit Submission. It is Document#24. I dPocumentation o ntationtha, ,. ..._,..------ am submitting it here again. See Document#24 Round 1. ESR-206 Roof Classification of your roof classA(ESRrepo,t. Assemblies Incorporating Versa-shield. The Roof Assemblies is high lighted in Yellow. class A(ESR report, UL listing,etc.) _,,"°m - Subject: PlanCheck ✓ _ Page Label:A-501 ARCHITECTURALDETAILS Please revise this note, "R49 :== —I1� batt insulation spray foam" is -mmJ����z Author:justinh -- •_� -� confusing as to what you are al-`.� File Name:A Architecture.1O15Waters.2018 4.pdf E _ ,;.....a . actually proposing. ___ i The details have been corrected. Subject: PlanCheck ✓ Page Label: A-501 ARCHITECTURALDETAILS Foundation walls are required to ® _ extend 6"or more above grade Author:justinh per R4O4.1.6(4"if stone veneer File Name: A-Architecture.1O15Waters.2018-4.pdf y is used). Revise all applicable details to show compliance with m_ this. w ,,e-mi All foundation details have been revised to comply with R4O4.1.6 r__ RECEIVED 02/07/2019 ASPEN BUILDING DEPARTMENT 7. Subject: PlanCheck ✓ The 2"x2"square handrail O PoNJOATICN.HEATED STONE TESIALE'efed 10 ooni Page Label:A-501 ARCHITECTURALDETAILS na exceeds the perimeter allowed m°,z11°w hi h Autor:justinh typ°11na° fora type II handrail, please awep fB4SP° _ File Name:A-Architecture.1015Waters.2018-4.pdf ya:emira revise to comply as either a type The handrails have been revised to 1-1/2" I or type II handrail. rtin 4m_ O N NDRA1L O WALL Tr :IREaTp''- I Subject: PlanCheck ✓ Page Label:A 601 WINDOW ELEVATIONS Identify all windows that require I LEVEL I N. FLOOR Author:justinh safety glazing individually on the File Name: A-Architecture.1015Waters.2018-4.pdf window schedule. Identify all windows that require safety glazing individually on the window The windows have been identified that require safety glazing. schedule. Subject: PlanCheck ✓ Page Label:A-601 WINDOW ELEVATIONS This example energy report Author:justinh should be removed. It is not - File Name: A-Architecture.1015Waters.2018-4.pdf specific to your window package UPPER LEVEL FIN.FLQOR __ -- _ and it does not meet our MI� o .. The document has been removed. amended energy code = requirement of.28 U value. MAIN LEVEL FIN.FLOOR T •�' LOWER LEVEL FIN.FLOOR == WINDOW ELEVATIONS-VIEWED FROM THE OUTSIDE SCALE:I/4"=I'-0" ELEVATIONS ENGINEER LETTER.pdf(1) ew .• � Subject: PlanCheck "`°"'°°µ'°"°°''°°'�e Page Label: 1 ✓ All fenestration (not just windows �° ��'°°' °tzm:::-;:n .'-'':::7"': and glass doors)are required to =,=: _.,--"—w.---N.°--: Author:justinh ,,, •°H°°°°° File Name: ENGINEER LETTER.pdf meet the .28 U value,this "p�"�•Po"�•-'•'"""'w"'�•=_�� includes the garage door. The Engineer letter has been revised to state that all door Please revise this note to more fenestrations will comply with the .28 U value. See clearly state that all doors will Document# 16. REScheck Letter. comply. M-Mechanical Engineering.1015Waters.2018.4.pdf(5) „ ', Subject: PlanCheck •- memm` =R6-=' — 1 ✓ Calculate the equivalent length Page Label: M1-1 " — -- - a Author:justinh of the dryer exhaust and provide 7 .. �'" a cutsheet on the proposed long �"_ �" -� e File Name: M-Mechanical Engineering.1015Waters.2018.4.pdf _ run dryer or booster fan if it /,' '' ��� ��- W exceeds 35'. z o; See Mechanical Responses from BCE. - LA E RECEIVED 02/07/2019 ASPEN BUILDING DEPARTMENT = Subject: PlanCheck ✓ m���ta� Provide a plumbing plan with �; -- Page Label: M1-1 ��� I . - isometric(or flatometric) Author:justinh „7� File Name: M-Mechanical Engineering.1015Waters.2018.4.pdf showing which fixtures will drain �l�__I into the lift station sump. Only those fixtures that cannot drain . See Mechanical Responses from BCE. to the sewer by gravity may drain to the lift station. 2015 IPC Po„ 1, 712.1 4 \ MECHANICAL-LOWER LEVE Subject: PlanCheck i Page Label: M1 2 Outdoor air intakes are required Author:justinh to be 10'horizontally from }_ ! t File Name: M-Mechanical Engineering.1015Waters.2018.4.pdf hazardous or noxious _ contaminant sources, carports 5.. ry5*= -Lit See Mechanical Responses from BCE. and driveways are considered to —— be a contaminant source. Please revise to comply with IMC 401.4. 1 NOTES. Subject: PlanCheck ✓ X 1.PROVIDE ZONE DAMPERS WITH 24V ACTUATORS. Show your calculations 2.PROVIDE ZONE CONTROL BOARD. Page Label: M1-4 3.PROVIDE DIGITAL PROGRAMMABLE THERMOSTATS. Author:justinh demonstrating the balanced File Name: M-Mechanical Engineering.1015Waters.2018.4.pdf whole house ventilation system Show your calculations is sized adequately. demonstrating the balanced whole house ventilation system is sized See Mechanical Responses from BCE. adequately. Subject: PlanCheck ✓ X Page Label: M1 4 Show that your whole house Author:justinh ventilation system is balanced 1NPI within 20%as required by COA P.PI File Name: M-Mechanical Engineering.1015Waters.2018.4.pdf Show that your whole house ventHation — amendments to R403.6 of the system is balanced within 20 s as IECC. reR 03.6 by COthe amendments to See Mechanical Responses from BCE. R403.6 of the IECC. {� :s REEMP.pdf(1) Subject: PlanCheck ✓ Please fill out a current 2015 Page Label: 1 Author:justinh IECC REMP worksheet as you File Name: REEMP.pdf are under the 2015 codes. _ Response: In the Documents section, See 31.The REMP sheet has been updated from 2009 - — — to 2015. See Document#31 RECEIVED 02/07/2019 ASPEN BUILDING DEPARTMENT SPECIAL INSPECTIONS.pdf(1) :..� Subject: PlanCheck Page Label: 3 Please also provide an . u" Author:justinh inspected fabricator's signature if field welding is proposed. -- File Name: SPECIAL INSPECTIONS.pdf INIOIMIM An inspected fabricator's signature has been added. See Document# 17. Round 1 SPECS.pdf(2) Subject: PlanCheck/ Page Label: 1 In the future please break your a Author:justinh specs and cutsheets into File Name: SPECS.pdf multiple files for the various In the future please break your specs and pieces of equipment. It is very cutsheeious ieces of equipme t.It isbvery cuinto mulple mbersoomehe rto navigate The Mechanical Specifications and cut- cumbersome to navigate a 110 O page spec package that is all one file page spec package that is all sheets have been broken down into their one file. various pieced of equipment See Documents # 16. Round 1 Subject: PlanCheck Page Label: 104 Provide cutsheets that actually -•• -- Author:justinh list your model spa, I can't File Name: SPECS.pdf accept cutsheets where your model was apparently typed on New cut sheets of the proposed spa and cover after the fact for documentation _,_"— —u® have been submitted and replaces the previous of CEC certification and cover models. See Document#31 Round 1. safety rating. S-Structural Engineering.1015Waters.2018.4.pdf(2) Subject: PlanCheck Revise all drawings Page Label: S1.1 FOUNDATION PLAN (architectural, civil, structural)so < Author:justinh File Name: S-Structural Engineering.1015Waters.2018.4.pdf that the foundation above grade extends xat The details have been revised to comply with R404.1.6. where stone veneer is used). oiwir Per the civil grading plan the foundation TOW would be below grade here,there are other areas with same problem. Be sure all drawings are coordinated in order to comply with R404.1.6. o o Q Subject: PlanCheck, Please verify that the roof deck Page Label: S1.4 ROOF FRAMING PLAN Author:justinh framing has been sized yaazie. File Name: S-Structural Engineering.1015Waters.2018.4.pdf adequately to support the • proposed hot tub. i' o Attached please find a letter from the Structural Engineer stating that � ® �,...! the framing has been designed to support the proposed hot tub. Ssee trak' Document#39. Round 1 ®� . K...:...y�a IIPT o oe RECEIVED 02/07/2019 ASPEN BUILDING DEPARTMENT