Master Permit.1015 Waters Ave.0204.2019 (55).ARBK
' ® KNIGHT®WILL MOUNT BOILER PRODUCT SUMMARY �-"'`',,...,..� (WH]55,000-399,999 BTU/HR WH-055 WH-085 WH-110 WH-155 WH-199 WH-285 WH-399 WATER GALLON CAPACITY 2.5 2.5 3.5 3.5 5.0 5.0 H 6.5 HEATING SURFACE(SQ.FT.) 5.92 8.33 10.00 14.07 15.66 21.60 36.58 WATER CONNECTIONS 1" 1" 1" 1" 1-1/4" _ 1-1/4" 1-1/2" 20°F AT WATER FLOW(GPM) 5 8 10 15 19 27 38 HEAD LOSS(FT.OF HD.) 0.27 0.94 1.53 3.50 1.13 2.42 1.42 35°F AT WATER FLOW(GPM) 3 5 6 9 11 16 22 HEAD LOSS(FT.OF HD.) 0.10 0.37 0.55 1.45 0.38 _ 0.85 0.48 MAX.WORKING PRESSURE(PSI) 80 80 80 80 80 80 80 #OF RELIEF VALVES 1 1 1 1 1 1 1 RELIEF VALVE SIZE 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" RELIEF VALVE RATING(MBH) 535 535 535 535 535 _ 535 535 RELIEF VALVE PRESSURE RATING(PSI) 30 30 30 30 30 30 30 GAS INLET CONNECTION 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 3/4" MAX.INLET PRESSURE,NAT 14.0"w.c. 14.0"w.c. 14.0"w.c. 14.0"w.c. 14.0"w.c. _ 14.0" w.c. 14.0"w.c. MIN.INLET PRESSURE,NAT 4.0"w.c. 4.0"w.c. 4.0"w.c. 4.0"w.c. 4.0"w.c. 4.0"w.c. 4.0"w.c. MAX.INLET PRESSURE,LP 14.0"w.c. 14.0"w.c. 14.0"w.c. 14.0"w.c. 14.0"w.c. 14.0"w.c. 14.0"w.c. MIN.INLET PRESSURE,LP 8.0"w.c. 8.0"w.c. 8.0"w.c. 8.0"w.c. 8.0"w.c. 8.0"w.c. 8.0"w.c. BTU/HR INPUT 55,000 85,000 110,000 155,000 199,999 _ 285,000 399,999 BTU/HR OUTPUT(HIGH FIRE) 52,250 80,750 104,500 147,250 189,999 270,750 379,999 BTU/HR OUTPUT(LOW FIRE) 10,450 16,150 20,900 29,450 38,000 54,150 76,000 ELECTRICAL VOLTAGE/HEATER 120 120 120 120 120 _ 120 120 VOLTAGE/CONTROL 24 24 24 24 24 _ 24 24 TOTAL AMPS 0.5 0.5 0.5 0.5 1.5 1.5 H 2.0 #OF ELECTRICAL CONNECTIONS 1 1 1 1 1 _ 1 1 DIMENSIONS _ HEIGHT 33-1/4" 33-1/4" 33-1/4" 33-1/4" 33-1/4" 33-1/4" 35-1/2" WIDTH 18-1/2" 18-1/2" 18-1/2" 18-1/2" 18-1/2" 18-1/2" 25" DEPTH 16" 16" 19" 19" 19" _ 19" 21-3/4" SERVICE CLEARANCES _ FRONT 24" 24" 24" 24" 24" 24" 24" BOTTOM 24" 24" 24" 24" 24" 24" 24" RIGHT SIDE 0" 0" 0" 0" 0" 0" 0" LEFT SIDE 24" 24" 24" 24" 24" _ 24" 24" TOP 6" 6" 6" 6" 6" 6" 6" DIRECT VENTING SIZE 2" 2" 3" 3" 3" 3" 4" VENT CATEGORY IV IV IV IV IV _ IV IV VENT MATERIAL PVC/CPVC/SS PVC/CPVC/SS PVC/CPVC/SS PVC/CPVC/SS PVC/CPVC/SS PVC/CPVC/SS PVC/CPVC/SS Lochinvar,LLC•300 Maddox Simpson Pkwy•Lebanon,TN 37090•615-889-8900/Fax:615-547-1000 www.Lochinvar.com WH-PS-02 I u l2-Printed in U.S.A. In the future please break your specs and cutsheets into multiple files for the various pieces of equipment. It is very cumbersome to navigate RECEIVED a 110 page spec package that is all one file. 04/06/2018 ASPEN BUILDING DEPARTMENT HIGH EFFICIENCY CONDENSING BOILERS I Kcillill �TM NIGH' WALL MOUNT BOILER CON XUS' REMOTE CONNECT CAPABLE - SMARTV Ij OPERATING CONTROL FEATURING _ A BUILT-IN CASCADING SEQUENCER IllehwaF 7 MODELS: 55,000 - 399,999 BTU/HR Wit5:1 TURNDOWN RATIO itr.—__ _____-....if LESS THAN 20 ppm NOx DIRECT VENT FLEXIBILITY TO 100 FEET 95% AFUE h ��_�` EFFICIENCY host Efficient LOW NOx - 2015 ..°ed l ed ENERGY STAR vwwenergyslar.gov fc }v ?�.,, t,H� ' EM0.4 :,vimL©© ®VE� HIGH EFFICIENCY BOILERS &WATER HEATERS Lochinvci.rcm TM 1( THE SMARTEST CHOICE FOR NIGH CONDENSING BOILER PERFORMANCE WALL MOUNT BOILER The KNIGHT Wall Mount, engineered with Lochinvar's exclusive SMART SYSTEMTM control and an array of other innovative features is far ahead of any heating boiler in its class.It promises and delivers ultimate ease of installation and maintenance.With up to 99% efficiency, low-NOx emissions and a fully modulating burner, it is the best"green choice"for today's environmentally focused market. Seven modulating/condensing stainless steel KNIGHT Wall Mount boilers are available with 55,000-399,999 Btu/hr inputs in a space- saving wall-mounted design.All are equipped for direct-vent installation with air intake and exhaust runs up to 100 feet using PVC,CPVC, Polypropylene or AL29-4C vent materials. This range of choices is ideal for residential or light-duty applications such as small hotels, schools and office buildings. For higher-demand applications, up to eight KNIGHT Wall Mount units can be installed utilizing the built-in cascading sequencer to deliver up to 3.2 million Btu/hr heating capacity. The KNIGHT Wall Mount Boiler reflects Lochinvar's constant commitment to providing all the options you need to serve every application. ADVANCED NEGATIVE REGULATION TECHNOLOGY KNIGHT safely and reliably operates with supply gas pressure as low as 4 inches water column. Negative Regulation (Neg/Reg)technology automatically adjusts fan speed to ensure the correct volume a and mix of fuel and air throughout the firing range. FIRE TUBE DESIGN 4 This fully welded ASME Certified stainless steel heat exchanger uses oval shaped tubes to pass heat from the products \ of combustion into the water stored in the vessel.To facilitate heat transfer the tubes are manufactured with dimples ,,C , -I Y to slow the flue products and extract available latent energy.With a fire tube design the flue products are inside `7. tapered passage ways and the water is passed through the vessel. Since the flue products pass through tubes ) . and the water is circulated through a larger diameter vessel a fire tube design allows for minimal head pressure loss through the boiler which allows the boiler to be installed easily into various hydronic applications. $t' WATER-BACKED COMBUSTION CHAMBER J j An outstanding feature of the fire tube design is a water backed combustion chamber. By having the combustion Ichamber surrounded by water the Knight Wall Mount has more heating surface area.This larger heating surface I area allows for efficiencies up to 99%. I FULLY MODULATING BURNER i The SMART SYSTEM allows fully modulating combustion with 5:1 turndown.The burner can fire as low as 20% 1 6 i4 •*� of maximum input and modulates the firing rate up to 100%as demand increases.The burner is a single t i"l`ate stainless steel assembly covered with woven steel mesh and fires in a 360° pattern along the entire length ^_ ` '. of the burner.This allows the compact KNIGHT to exceed the modulation capacities of units with larger - •, multiple burners. DIRECT VENTING UP TO 100 FEET KNIGHT offers 5 venting options and tremendous flexibility for placement of units within the building, because it permits direct-vent air intake and exhaust runs up to 100 equivalent feet using either PVC,CPVC,Polypropylene or AL29-4C stainless steel vent pipe. 5 FLEXIBLE VENTING OPTIONS Direct Vent Sidewall Direct Vent Vertical Vertical w/Sidewall Air Concentric Direct Vent Vertical* Concentric Direct Vent Sidewall* `\`� ��°*Optional VentKitSoldSeparately RESET `S MART c,42id QZ 1.-TEtq: 3 Kr SCROLL U TNNK; 11 : REFINED UESIGN PUTS MORE CONTR °�TcooR: 1 .4°F5118) MENU 56°p`138) AND INFORMATION AT YOUR FINGERTI i srScREEN sHpN • 1 Advanced features include: CI".-`+ r., • MULTI-COLOR GRAPHIC LCD DISPLAY Select ..... • NAVIGATION DIAL •—...." G .... Select • USB PORT • • ABILITY TO CONTROL UP TO THREE DIFFERENT SETPOINT TEMPERATURES • COMPATIBILITY WITH COPPER-FIN II NON-CONDENSING BOILER AT-A-GLANCE CREATE A FRONT-END LOADING SYSTEM AT-A-GLANCE COLOR CODING • BOILERS WITH DIFFERENT INPUTS CAN BE CASCADED TOGETHER _ TO MAXIMIZE BOILER PLANT TURNDOWN qaz qe REQUIRED • MODBUS CAPABILITY(OPTIONAL) MENU sSCREENoMEN ry� • DHW MODULATION LIMITING 11W— \, i\ • DHW NIGHT SETBACK* • 0-10 V BOILER RATE OUTPUT BLUE SCREEN YELLOW SCREEN RED SCREEN • 0-10 V SIGNAL TO CONTROL VARIABLE SPEED BOILER PUMP* Normal system Maintenance due-shows Lockout mode. • 0-10 V SYSTEM PUMP SIGNAL INPUT* operation. the installer's name and • HEAT DEMAND FROM 0-1OV INPUT number on the display. • INSTALLER CAN PROGRAM NAME AND NUMBER INTO THE BOILER • INSTALLER ADJUSTABLE FREEZE PROTECTION PARAMETERS • SEPARATELY ADJUSTABLE SH/DHW SWITCHING TIMES* • INSTALLER ACCESS TO BMS AND RAMP DELAY SETTINGS *EXCLUSIVE TO LOCHINVAR SMART SYSTEM CO ' (� STm The CON•X•US mobile communication platform allows SMART SYSTEM No a,\ -------- lato go where no other boiler has gone before: CON•X•US provides the ability to monitor and manage multiple Knight heating boilers without ever stepping into the mechanical rooms. CON•X•US will send alerts via text or e-mail notifying of changes in system status,and anytime,from anywhere,a user can check system sE��m,eoF w, status and re-program any boiler function.Once downloaded,the free CON•X•US mobile application allows for remote access to all SMART SYSTEM functions using an Internet-capable device. 'CON•X-US control board sold separately. NEW SELECTABLE CASCADE OPTIONS When multiple KNIGHT boilers are installed together, the SMART SYSTEM built-in sequencer can be set for"Lead-Lag" cascade or"Efficiency Optimized" cascade operation. LEAD-LAG CASCADE EFFICIENCY OPTIMIZED CASCADE I 1 I * __1 _- 1ir' ' iii! Ill , �������� The"lead"boiler modulates with demand to capacity. This feature optimizes the modulation capabilities of the As demand increases,additional boilers fire and modulate to Boiler Plant while evenly distributing run time across all capacity.This continues,with additional boilers firing and cascaded boilers. Every 24 hours the SMART SYSTEM modulating to capacity until all units are operating. Every 24 automatically shifts the 1st boiler on role to the next in hours,the SMART SYSTEM automatically shifts the lead boiler the sequence,distributing run time equally. role to the next in the sequence,distributing lead-lag runtimes equally. SMART SYSTEM Cascade allows 2-8 boilers to be sequenced. KNIGHT° WALL-MOUNT BOILER DIMENSIONS AND SPECIFICATIONS I LOW VOLTAGE ELECTRICAL AIR CONNECTIONS N INLET M G� HIGH VOLTAGE �� Q'� ELECTRICAL L - ro. O >a®0 0 CONNECTIONS R, �J FLUE ,_ I fe; INLET ®® DRAIN ENSATE A "Z- O (al @ RELIEF J D VALVE E F IOuThETI! G I 1 I t -- 1 ■ i H GAS 1 ,� I g c J ToP RIGHT BorroM KNIGHT HEATING BOILER DIMENSIONS AND SPECIFICATIONS Input Heatin Model Max. Min. *AFUE Capacity Net A B C D E F G H I I K L M N 0 Gas Water Air Vent Shipping Number MBH MBH % MBH MBH Conn.Conn. Inlet Size Wt.(lbs.) WHN055 55 11 95.0 51 44 33-1/4"18-1/2" 16" 11-3/4" 10-1/2" 6-1/2" 4" 1-1/2" 3" 14-1/2" 5-3/4" 4" 3" 16-1/4"5" 1/2" 1" 2" 2" 139 WHN085 85 17 95.0 79 69 33-1/4"18-1/2" 16" 11-3/4" 10-1/2" 6-1/2" 4" 1-1/2" 3" 14-1/2" 5-3/4" 4" 3" 16-1/4"5" 1/2" 1" 2" 2" 142 WHN110 110 22 95.0 102 89 33-1/4"18-1/2" 19" 14-1/2" 10-3/4" 7-3/4" 7-3/4" 2-1/4" 10" 15-1/2" 5" 3-1/4"3" 16-1/2"2-3/4" 1/2" 1" 3" 3" 159 WHN155 155 31 95.0 144 125 33-1/4"18-1/2" 19" 14-1/2" 10-3/4" 7-3/4" 7-3/4" 2-1/4" 10' 15-1/2" 5" 3-1/4"3" 16-1/2"2-3/4" 1/2" 1" 3" 3" 166 WHN199 199.9 40 95.0 185 161 33-1/4"18-1/2" 19" 14-1/2" 11-3/4" 8" 8" 1-1/4" 10' 16-3/4" 4-3/4" 3-1/4"2-3/4"16-1/2"3" 1/2" 1-1/4" 3" 3" 175 WHN285 285 57 95.0 264 229 33-1/4"18-1/2" 19" 14-1/2" 11-3/4" 8" 8" 1-1/4" 10' 16-3/4" 4-3/4" 3-1/4"2-3/4"16-1/2"3" 1/Z' 1-1/4" 3" 3" 184 WHN399 399 80 94.4 377 328 35-1/2"25" 21-3/4"17-1/Z' 12-1/2" 9-1/4" 9-1/2" 2-1/4" 13-1/4" 21-1/2" 9" 4-3/4"4" 22-1/2"3-3/4" 3/4" 1-1/Z' 4" 4" 213 Notes:Indoor installation only.All information subject to change.Change"N"to"L"for LP gas models.*WHN399 value is Thermal Efficiency SMART SYSTEM- FEATURES STANDARD FEATURES >SMART SYSTEM Digital Operating Control >Access to BMS Settings through Graphic >ENERGY STAR Most Efficient Recognition§ LCD Display Multi-Color Graphic LCD Display >95%DOE AFUE Efficiency5 Dial and Soft Ke s >High-Voltage Terminal Strip with Navigation Y >Modulating Burner with 5:1 Turndown >Three Boiler Set point Temperature Inputs 120 VAC/60 Hertz/1 Phase Power Supply P P P Direct-Spark Ignition Plus Domestic Hot Water Prioritization Three Sets of Pump Contacts >Low Voltage Terminal Strip Low-NOx Operation >Built-in Cascading Sequencer for Field Convertible from Natural to LP Gas up to 8 Boilers 24 VAC Device Relay Multiple Size Boiler Cascade Proving Switch Contacts >ASME Stainless Steel Heat Exchanger Lead Lag Flow Switch Contacts 30 psi ASME Relief Valve Alarm on AnyFailure Contacts >Vertical&Horizontal Direct-Vent Efficiency Optimization PVC,CPVC,Polypropylene or SS Venting up to Front End Loading Capability with Copper Fin II Runtime Contacts 100 feet >Outdoor Reset Control with Outdoor DHW Thermostat Contacts Air Sensor 3 Space Heat Thermostat Contacts >Smart System Control Programmable for Three Reset System Sensor Contacts >Condensate Trap Temperature Inputs DHW Tank Sensor Contacts >Other Features >Programmable System Efficiency Optimizers Outdoor Air Sensor Contacts Automatic Reset High Limit Night Setback Cascade Contacts Adjustable High Limit w/Manual Reset DHW Night Setback* 0-10 VDC BMS External Control Contact Boiler Circulating Pump Anti-Cycling 0-10 VDC Boiler Rate Output Contacts Wall-Mount Bracket Outdoor Air Reset Curve 0-10 VDC Variable Speed System Pump Signal Zero Clearances to Combustible Materials Input* 12-Year Limited Warranty Ramp Delay Boost Temperature&Time 0-10 VDC Signal to ontrol Variable (SeeeaWPartsty fora Details) pSpeed Boiler Pump* y >Three Pump Control Modbus Contacts OPTIONAL EQUIPMENT System Pump with Parameter for >Time Clock CON-X-US Remote Connectivity Continuous Operation >Data Logging Modbus Communication Boiler Pump with Variable Speed Hours Running,SpaceHeatingFlow Switch Pump Control* Low-Water Cutoff w Manual Reset&Test Domestic Hot Water Pump Hours Running,Domestic Hot Water / Ignition Attempts Alarm Bell >Domestic Hot Water Prioritization Last 10 Lockouts Concentric Vent Kit DHW tank piped with priority in >Maintenance Reminder SMART SYSTEM PC Software the boiler loop Condensate Neutralization Kit DHW tank piped as a zone in the Custom Maintenance Reminder with Contractor P p Contact Information BMS Gateway to LON or BacNet system with the pumps controlled by the Smart System Installer Ability to De-activate Multi-Temperature Loop Control DHW Modulation Limiting Service Reminder Sidewall Vent Termination Separately Adjustable Space Heat/DHW >Low-Water Flow Safety Control&Indication Floor Stand Switching Times* >Password Security Wireless Outdoor Sensor >Building Management System Integration >Customizable Freeze Protection Parameters FIRING CODES 0-10 VDC Input to Control Modulation >M9 Standard Construction or Set Point >M7 California Code 0-10 VDC Modulation Rate Output *Exclusive feature,available frgrjgri F 6, 0-10 VDC Input to Enable/Disable call for heat §WHN 55-285 only (�J Lochinvar,LLC Patent Pending ioehhr 300 Maddox Simpson Parkway - sio Lebanon,Tennessee 37090 '�� Q r\Most Efficient If (�' D l Q P:615.889.8900/F:615.547.1000 A Y t �7 .....ad CERTIFIED- rr�2U1g HIGH EFFICIENCY BOILERS&WATER HEATERS ■a©®G Lochinvar.com • ®---•.row.,- CERTIFIED® 'W e _ WHN-04 (Reprint WHN-o4 5/15) PDP-2.5M-9/15-Printed in U.S.A. LENNOX) INSTALLATION ©2013 Lennox Industries Inc. INSTRUCTIONS Dallas,Texas,USA CBWMV Series Units iii. AIR HANDLERS Technical ' 4 p 505,047M llll Publications 12/2013 Litho U.S.A. / Supersedes)/2013 Table of Contents Introduction 1 Shipping and Packing List 1 CBWMV Unit Dimensions 2 General 3 ILCBWMV Unit Parts Arrangement 3 CBWMV Unit Parts Description 3 et 1 NW A� CBWMV Unit Optional Accessories 3 I Requirements 3 RIO i �► Application 4 Installation - Setting Equipment 4 Duct System 5 Return Air Opening Guidelines 5 Filter Assembly & Filters 6 Plumbing 7 Electrical 7 Freeze-stat Operation 11 BDC3 Variable Blower Control Board 11 Blower Speed Adjustments 11 Initial Air System Purging 14 System Adjustments 14 THIS MANUAL MUST BE LEFT WITH THE Annual Service 14 HOMEOWNER FOR FUTURE REFERENCE Service Filters 14 Winterizing the CBWMV Unit 14 AWARNING Repair Parts List 14 Troubleshooting: Improper installation, adjustment, alteration, service or Continuous Fan Sequence of Operation 15 maintenance can cause property damage, personal inju- Heating Sequence of Operation 15 ry or loss of life. Cooling Sequence of Operation 16 Installation and service must be performed by a licensed Shipping and Packing List professional installer(or equivalent) or service agency. 1 - CBWMV Air Handler [NOTE - Includes freezestat mounted to the manifold.] AWARN I N G 1 - Bag assembly containing: The State of California has determined that this product 1 - Electrical make-up box may contain or produce a chemical or chemicals, in very 1 - Copper fitting low doses, which may cause serious illness or death. It 1 - Snap bushing may also cause cancer, birth defects, or reproductive 2 - Water line grommets harm. 3 - Wire nuts 2-7/8" cabinet plugs Check equipment for shipping damage. If you find any Introduction damage, immediately contact the last carrier. The CBWMV air handler/hot water coil unit is designed to A CAUTION be used with non-potable boiler systems for warm air heat- ing. A variety of Lennox air conditioning systems may be Unit is designed to be used with non-potable boiler sys- applied to the CBWMV unit for optional cooling. terns only. n 12/2013 Page 1 50 �6/2 018 1111111011111111010111101111111111111111111 iiii a iii iv i ui ii y iii i t aide BUILDING DEPARTMENT CBWMV Unit Dimensions - inches (mm) *NOTE - Single side inlet applications result in approximately 4 percent reduction of CFM on B-size units and approximately WATER INLET 5 percent reduction of CFM on C-size units. pill,. SUPPLY AIR OPENING F WATER OUTLET D 23-3/4(603) OPTIONAL EXTERNAL SIDE RETURN 25(635) AIR FILTER KIT(Either Side)-Not for TOP VIEW use with optional Return Air Base. 28-1/2 A ► (724) B ► f 9/16 19-7/16 9/16 (14) ALTERNATE WATER I (494) (14) INLET(far side) 1 I o 0 1 A 1-1/4"(32) - ) 1-3/4"(44) - 10-1/2" (267) OPTIONAL ALTERNATE EXTERNAL WATER OUTLET SIDE RETURN AIR FILTER KIT 2 ELECTRICAL INLET (Either Side) (51) (Either Side) 40 =O (1016) /1—f 111.1 14-3/4 4 I 23 (375) 16 (102) (584) Jr *OPTIONAL 14 (406) RETURN CUTOUT (356) (Either Side) AIR FLOW i J 11-15/16(49) C 16 23-1/2 J *Bottom Return hil- 4 ( ) (597) II 4 4-1/4 3/4(19) Air Opening 3/4(19) (108 *Bottom Return Air Opening FRONT VIEW ) SIDE VIEW CBWMV Model No. A B C D E F G -24B-040 17-1/2(445) 16-3/8(416) 16 (406) 1-1/2 (38) 1-3/4(44) 8(203) 2 (51) -36B-070 -36C-090 -60C-100 21 (533) 19-7/8(454) 19-1/2 (495) 2 (51) 2-1/2 (64) 9-1/2(241) 1-1/2 (38) -60C-120 RECEIVED Page 2 04/06/2018 505,547M ASPEN BUILDING DEPARTMENT General CBWMV Unit Optional Accessories These instructions are intended as a general guide and do Refer to the CBWMV Product specification (EHB) for a not supersede local codes in any way. Consult authorities current list of available accessories. having jurisdiction before installation. Only qualified ser- vice technicians or installers may install and service this Requirements unit. CBWMV Unit Parts Arrangement A WARNING Improper installation, adjustment, alteration, service or CBWMV Unit maintenance can cause personal injury, loss of life, or HOT WATER INSULATED damage to property. COPPER STEEL Installation and service must be performed by a qualified TUBE COIL CABINET installer or service agency. Installation of Lennox CBWMV unit must conform with lo- ...\.<7;.____, ______ cal building codes. Refer to the electrical section (Page 7) for US and Canadian electrical regulations. // When paired with a water heating device, refer to local building codes for special considerations. Refer to water 1/7 % heating device for agency and service clearances. Clear- �� ances to combustibles for the CBWMV unit only is zero %„ inches on all sides. Table 1 lists recommended service // "" clearances. '� Table 1 CBWMV Unit Service Clearances Clearances Location Inches(mm) vi ��I ( , i � � Recommended Front Access 30(762) +;,i �� Service Access Panel \'. NOTE- Service access clearance must be maintained. / Accessibility and service clearances must take prece- SUPPLY AIR dence over fire protection clearances. CBWMV L7 BLOWER For installation in a residential garage, unit must be lo- CONTROL BOX cated or protected to avoid physical damage by vehicles. Figure 1 The CBWMV unit must be installed so that its electrical components are protected from water. CBWMV Unit Parts Description When the CBWMV unit is used with an air conditioner, the Blower air handler shall be installed on the upstream side of the The CBWMV is equipped with a variable speed motor that cooling evaporator coil to avoid freeze-up of water system provides separate cooling and heating CFM selections and condensation. With a parallel flow arrangement, a and low continuous fan speeds. damper(or other means to control the flow of air)must ad- equately prevent chilled air from entering the air handler. If Hot Water Coil the damper is manually operated, it must be equipped to The copper tube coil is equipped with aluminum fins which prevent operation of either the heating or the cooling unit, provide excellent heat transfer. Manual air bleed ports are unless it is in the full HEAT or COOL setting. located in the copper tubing to release trapped air in the NOTE-CBWMV series units must not be used in or for the water circuit in all unit configurations. following applications: Blower Control • construction heater-during any phase of construction The control provides a fixed blower delay of 45 seconds ON /30 seconds OFF on a W call. • unit heater Thermostat and accessory connections are made to the • mobile home heater terminal strips in the control box. • potable water applications RECEIVED Page 3 04/06/2018 cB( s BUILDING DEPARTMENT Application CBWMV Multi-Positional Unit The CBWMV unit is designed for use in non-potable water /'/ boiler systems. The water heating device must be ade- / AIIR quate to provide enough heat according to the Product ;/% , �' Specification bulletin. The water heating device must pro- / FLOW _ �\\ vide a minimum of 6 gallons/minute for small units (CBW- MV-040, -070) and 9 gallons/minute for large units (CBW- RIGHT HAND DISCHARGE` MV-090, -100, -120). I AIR I I LOW Installation - Setting Equipment I AIR FLOW UPFLOW 1 AWARNING DOWNFLOW BASE This product contains fiberglass wool. \ FLOW ♦ AIR /\ i Disturbing the insulation during installation, mainte- /'/ 1-1 nance, or repair will expose you to fiberglass wool dust. Breathing this may cause lung cancer. (Fiberglass wool , IIIIIUM LEFT HAND DISCHARGE* is known to the State of California to cause cancer.) DOWNFLOW Fiberglass wool may also cause respiratory, skin, and *CBWMV units must not be installed horizontally on the front or eye irritation. back of the unit. To reduce exposure to this substance or for further infor- Figure 2 mation, consult material safety data sheets available Units may be horizontally installed in either attic or crawl from address shown below, or contact your supervisor. space. Lennox Industries Inc. P.O. Box 799900 A CAUTION Dallas, TX 75379-9900 CBWMV series units are shipped with an antifreezether- The boiler installation must conform to the requirements of mostat to prevent the water coil from freezing. The the authority having jurisdiction or, in the absence of such freeze stat is installed at the factory but must be field requirements, to the latest revision of the National Fuel wired (see figures 12 and 13). Do not bypass this feature Gas Code, ANSI Z223. (Available from the American Gas when you install or run the unit. Association, 8501 E. Pleasant Valley Road, Cleveland, OH 44134). Reference should also be made to local gas A CAUTION utility regulations and other codes in effect in the same area in which the installation is to be made. When installed Use a drain pan for installations over finished living in Canada: The latest revision of the CAN1/CSA-B149.1 and/or B149.2 Installation Codes for Gas-Burning Equip- areas. ment and/or local codes. Either suspend the unit from the roof rafters or floor joists Determine the CBWMV unit installation location and posi- or mount on a platform. The CBWMV unit must be level tion units so that door panels are accessible. Keep in mind and well supported. routing of the water and plumbing lines and electrical con- NOTE- 1/2 hp and 1 hp blower motors are equipped with nections. three flexible legs and one rigid leg. The rigid leg is The CBWMV unit is multi-positional. No adjustment is nec- equipped with a shipping bolt and a flat white plastic wash- essary to apply unit for upflow or horizontal discharge. er(rather than the rubber mounting grommet used with a Downflow applications with add-on cooling coils require flexible mounting leg). The bolt and washer must be re- field-fabricated transitions that provide at least 6 inches of moved before the air handler is placed into operation. clearance for the CBWMV unit's inlet/outlet water lines. After the bolt and washer have been removed, the rigid leg See figure 2 for examples. will not touch the blower housing. RECEIVED Page 4 04/06/2018 505,547M ASPEN BUILDING DEPARTMENT Duct System Side Return Use industry-approved standards (such as those pub- For side return air applications, cut the air handler cabinet lished by Air Conditioning Contractors of America or Amer- at the maximum return air dimensions shown on page 2. See figure 3 for a typical side inlet arrangement with a tran- ican Society of Heating, Refrigerating and Air Conditioning sition and filter. Engineers)to size and install the supply and return air duct system. This will result in a quiet and low-static system that NOTE - Single side inlet applications result in approxi- has uniform air distribution. mately a 4 percent reduction of CFM on B-size units and NOTE - Do not operate the air handler with an external approximately a 5 percent reduction of CFM on C-size static pressure that exceeds 0.8 inches w.c. Higher exter- units: nal static pressures may cause erratic operation. Return Air Plenum Side Return Air With Transition And Filter A IMPORTANT Return air must not be drawn from a room where any fos- 20"X 25"X 1° sil fuel appliance (ie., a water heater) is installed. o (508MM X 635MM X 25MM) CLEANABLE FILTER When return air is drawn from a room, a negative pres- sure is created in the room. If a fossil fuel appliance is op- erating in a room with negative pressure, the flue prod- ucts can be pulled back down the vent pipe and into the RETURN AIR room. This reverse flow of the flue gas may result in in- PLENUM complete combustion and the formation of carbon mon- oxide gas. This toxic gas might then be distributed TRANSITION throughout the house by the air handler duct system. Return Air Opening Guidelines Figure 3 NOTE-Do not bring in air from the back of the unit. Return air can be brought in from the sides or bottom only. Return Air Base Bottom Return For return air with the optional return air base (RAB), see If the air handler is installed on a platform with bottom re- figure 4 (and refer to installation instructions provided with turn, make an airtight seal between the bottom of the air Return Air Base kit). handler and the platform to ensure that the air handler op- erates properly and safely. Use aluminum tape or mastic *NOTE- Both unit and return air base openings must be between the plenum and the air handler cabinet to ensure connected to and entirely covered by a single plenum or a tight seal. The air handler is equipped with a removable IAQ accessory opening. Optional side return air filter kits bottom panel to facilitate installation. cannot be used with RAB Return Air Base. Optional Return Air Base and Unit Dimensions - Inches (mm) 4 (102)- *23(584)Overall(Max.) 0 NOTE-IN SIDE RETURN APPLICATIONS, THE RAB *Minimum IS REQUIRED FOR 100% 11 (279) CFM CAPACITY. *Maximum *Height varies 14(356) with plenum or 'Unit IAQ accessory Side Return height. AIR FLOW Air Openings Opening (Either Side) \ RETURN 7-1/4 *Base 5-5/8 AIR BASE (184) Opening (143) 17(432)RAB-B(98M60) 23(584) 3/4 21 (533)RAB-C(98M58) 7/8(22)—M. 27-5/8(702) I (19) FRONT VIEW SIDE VIEW Figure 4 RECEIVED Page 5 04/06/2018 cB( s BUILDING DEPARTMENT Removing the Bottom Panel (bottom return or return 2. Install one bolt and two nuts into each hole. Screw the air base configurations)—Remove the two screws that first nut onto a bolt and then insert the bolt into a hole. secure the bottom cap to the air handler. Pivot the bottom A flat washer may be added between the nut and the cap down to release the bottom panel. Once the bottom bottom of the unit. panel has been removed, reinstall the bottom cap. See fig- 3. Screw another nut onto the bolt on the inside of the air ure 5. handler base. A flat washer may be added between the nut and the bottom of the unit. Removing the Bottom Panel 4. Adjust the outside nut to the appropriate height and tighten the inside nut to secure the arrangement. Horizontal Applications The CBWMV air handler can be installed in horizontal ap- r plications. Refer to Product Specification bulletin for addi- 0 tional information. Allow for clearances to combustible ma- terials as indicated on the unit nameplate. This air handler may be installed in either an attic or a fig crawlspace. Either suspend the air handler from roof raf- ters or floor joists, as shown in figure 7. The unit must be �- \ supported at both ends and beneath the blower deck to /OTTOMCAP prevent sagging. SCREW \� — Unit Suspended in Attic or Crawlspace BOTTOM PANEL Figure 5 1/4IN. ---------------- RODS Leveling an Upflow Unit—When the side return air inlets are used in an upflow application, it may be necessary to ------------ install leveling bolts on the bottom of the air handler. Use DRAIN field-supplied corrosion-resistant 5/16 inch machine bolts = PAN ALLOW (4) and nuts (8). See figure 6. SUFFICIENT CLEARANCE NOTE- Maximum leveling bolt length is 1-1/2 inches. BETWEEN ROD AND UNIT TO REMOVE Leveling Bolt Installation ACCESS PANEL. 3/8(10) inches(mm) ANGLE IRON AIR HANDLER FRONT U-CHANNELS rill:_i 1-3/4(44) Figure 7 3/8(10) ff NOTE - Heavy-gauge, perforated sheet metal straps (plumbers'straps)maybe used to suspend the unit from roof rafters or ceiling joists. When suspending the unit in this manner, support must be provided for both the ends 1-3/4(44) LING BOLT and the middle of the airhandler to prevent sagging. Straps CATIONS must not interfere with plenum or water piping. Securing screws should be 1/2 inch from the top edge and 1-1/2 inch LEVELING BOLT from the side edge in all cases.Cooling coils andsupply LOCATIONS3/8(10) and return air plen urns must be supported separately. -; NOTE- When the air handler is installed on a platform in a crawlspace, it must be elevated enough to avoid water 111--- Le damage and to allow the optional evaporator coil to drain. �0 Horizontal and Downflow Applications 3/8(10) 1------"ii 1-3/4(44) Return air can be brought in through the end of an air han- dler installed in the horizontal or downflow application.The 1-3/4(44) air handler is equipped with a removable bottom panel to Figure 6 facilitate installation (see figure 5). 1. Lay the air handler on its back and drill a 5/16 inch di- Filter Assembly & Filters ameter hole in each corner of the air handler's bottom. This unit is not equipped with a filter or rack. A field-pro- See figure 6 for the correct location of the holes. Drill vided high-velocity filter is required for the unit to operate through the bottom panel and the bottom flange of the properly. Table 2 lists recommended filteR( IVED cabinet. must be in place anytime the unit is oper V Page 6 04/06/2018 505,547M ASPEN BUILDING DEPARTMENT Table 2 nections secured to the lower left coil manifold for left side Recommended Filter Sizes make-up box installations. For right side make-up box installations, remove the wire tie that holds the line voltage Air Handler Filter Size connections and pull excess wires into blower deck/control Cabinet Size Side Return Bottom Return box area as shown in figure 8. 17-1/2" 16 X 25 X 1 (1) 16 X 25 X 1 (1) Install make-up box (provided for line voltage wiring in the 21" 16 X 25 X 1 (1) 20 X 25 X 1 (1) unit's bag assembly) as shown in figure 9. Plumbing ' - Make-up Box Wiring Pipe and Fitting Specifications I Refer to local building and plumbing codes for approved copper pipe and fittings. /4- I ti r... 1 Plumbing Procedures WIRES SHOWN AS SHIPPED, Refer to the installation instructions of the water heating ROUTED FOR LEFT SIDE device to be used with the CBWMV unit. Follow the recom- MAKE-UP BOX INSTALLATION —L mendations outlined in that instruction as well as govern- • ff ing plumbing codes and practices. FOR RIGHT SIDE MAKE-UP 7;.� BOX INSTALLATION— �'� Plumbing Checklist �k • Flush water lines between the CBWMV unit and the REMOVE WIRE TIE, d �e water heating device before start-up. Normal flushing I PULL EXCESS WIRE INTO 1— procedures should be used to rid the system of con- BLOWER DECK/CONTROL ei� BOX AREA. ,� taminants and foreign debris. W IGI -' • CBWMV units are installed in non-potable systems. Vk aua ISM Electrical „ .�. Wiring and grounding must conform to the current National Electric Code ANSI/NFPA No. 70, or Canadian Electric Code Part I, CSA Standard C22.1, and local building -Ills codes. Refer to following wiring diagrams. See unit name- 0 . . 0 plate for minimum circuit ampacity and maximum over cur- ® rent protection size. - - Select the proper supply circuit conductors in accor- Figure 8 dance with tables 310-16 and 310-17 in the National Electric Code, ANSI/NFPA No. 70 or tables 1 through 4 in the Canadian Electric Code, Part I, CSA Standard Interior Make-Up Box Installation C22.1. MAKE-UP A CAUTION BOX MAKE-UP BOX USE COPPER CONDUCTORS ONLY. \ °" et o ' • AWARNING o Electric shock hazard. Can cause injury o or death. Before attempting to perform iiii any service or maintenance, turn the lir electrical power to unit OFF at disconnect switch(es). Unit may have multiple power 1 V o supplies. LEFT SIDE RIGHT SIDE Refer to figure 12 for schematic wiring diagram and trouble- 4shooting. ••' N. Line Voltage (120V) 4 Line voltage field supply conductors are terminated at the Figure 9 CBWMV unit.The unit is shipped with the line voltage con- RECEIVED Page 7 04/06/2018 CB) r"ERmS BUILDING DEPARTMENT Electrostatic Discharge (ESD) - Precautions And National Electric Code (ANSI/NFPA No. 70) for the Procedures USA and current Canadian Electric Code part 1 (CSA standard C22.1) for Canada. A green ground wire is A CAUTION provided in the field make-up box. 5. Install the room thermostat according to the instruc- Electrostatic discharge can affect electronic compo- tions provided with the thermostat. See table 3 for field nents. Take precautions during air handler installation wiring connections in varying applications. If the air and service to protect the air handler's electronic con- handler is being matched with a heat pump, refer to the trols. Precautions will help to avoid control exposure to FuelMaster21 a installation instruction. electrostatic discharge by putting the air handler, the Removeable Jumpers control and the technician at the same electrostatic po- tential.Neutralize electrostatic charge by touching hand Removeable Jumper DS to Y1—The factory-installed and all tools on an unpainted unit surface, such as the wire jumper that connects terminals DS and Y1 on the TB1 blower deck,before performing any service procedure. terminal strip in the control box must be removed when the air handler is installed in a system supporting dehumidifi- Refer to table 3 for field wiring. cation using a SignatureStat thermostat (e.g., HumidiM - 1. Refer to the CBWMV unit's nameplate for minimum trol®Enhanced Dehumidification Accessory or Harmony zone controls). circuit ampacity and maximum overcurrent protection size. Removeable Jumper R to 0—The factory-installed wire jumper that connects TB7 (24V) terminal R to TB1 termi- 2. Install a separate disconnect switch (protected by ei- nal 0 must be removed when the air handler is installed in ther fuse or circuit breaker)near the air handler so that applications which include a heat pump unit and the Fuel- power can be turned off for servicing. Master21®control board. If the jumper is left intact, termi- 3. Complete the wiring connections to the equipment. nal 0 will remain energized, eliminating the heat mode in Use the provided unit wiring diagram and the field wir- the heat pump. ing diagrams shown in table 3. Use 18-gauge wire or Removeable Jumper Y1 to Y2—The factory-installed larger that is suitable for Class II rating for thermostat wire jumper that connects Y1 and Y2 on the TB1 terminal connections. strip must be removed if two-stage cooling is used. If the 4. Electrically ground the unit according to local codes or, jumper is not removed the outdoor unit will only operate in in the absence of local codes, according to the current second-stage cooling. Table 3 Field Wiring Application Jumper Settings(See figure 12) Thermostat (Application) TB1 Y1 to Y2 TB1 DS to Y1 TB1 R to 0 Wiring Connections 1 Heat/ 1 Cool with Yes No No SignatureStaf CBWMV OUTDOOR SignatureStat'"" Thermostat (Remove) (Remove) TERMINALS UNIT [Single-Stage Heat Pump] 0 C:)\ 0 \..-JUMPERS O Q \`- REMOVED / r,� ii O O '/ O 2 Heat/2 Cool with No No No SignatureStaf CBWMV OUTDOOR SignatureStat- Thermostat (Remove) (Remove) (Remove) TERMINALS UNIT [Two-Stage Heat Pump (Refer 0 ®\ to FM21 Instructions)] ® - --© 0 O\,I ALLRE JUMPERS OVED 0 ® 0 O ©r �- -O O/ ® "0" terminal used only with heat pumps. RECEIVED Page 8 04/06/2018 505,547M ASPEN BUILDING DEPARTMENT Indoor Blower Speeds Accessory Field Wiring (TB66 & TB67) 1. When the thermostat is set to "FAN ON," the indoor blower will run continuously at approximately 38% of the second-stage cooling speed when there is no cool- Connect wires from accessories (e.g. powered air clean- ing or heating demand. ers, humidifiers) to terminal blocks TB66 and TB67 (see 2. When the CBWMV is in the heating mode, the indoor detail in figure 11). blower will run on the heating speed designated by the position of the HEAT pin. 3. When there is a cooling demand,the indoor blower will run on the cooling speed designated by the position of I CBWMV Control Box the COOL pin. TERMINAL BLOCKS TB2 TB13 (HOT) (NEUTRAL) TRANSFORMER Accessory Field Wiring (K212) 4 -T1 'e�e���1 e. % Connect field wiring to 3PDT relay K212 (Lennox part ,�I1 ' � - . 67K66) as shown in figure 10. DOOR _ I MO irn(14104CB8 CIRCUIT INTERLOCK BREAKER SWITCH �,I `� ,.I�1>,1II Accessory Relay Field Wiring (K212) BDC3 i� ����®® FI `I`'I` •D WIRING VARIABLE STRAIN 1 2 3 CONTROL -' � :1;1111-4t.:.;f1 ��_.-� RELIEF`: ` BUSHING nn nFIELD ORY '.aYY Y�� FIELD TB66 f , • • - 0 WIRING i lep��� �� O 0 TERMINAL TB67 1.,,+p n411111 TERMINAL O D Q 7 8 9 BLOCKS yam+ g00450. BLOCK 24V 0 0 o f; ,� _ga O O 0 TERMINAL N� 1:741 1+li o RELAY BLOCK TB1 ACCESSORY RELAY 24V 125MA 1/4"QUICK CONNECT TERMINALS RELAY CONTACTS RATING 8 AMPS @ 120V MAX.24V COIL Figure 11 Figure 10 RECEIVED Page 9 04/06/2018yyfpV CBA pERmS BUILDING DEPARTMENT 120V ACC OR K43 ECON. Typical CBWMV Wiring Diagram (IF USED) G D THERMOSTAT RTION y n ANTI-FREEZE `f THERMOSTAT Eilal A2 THERMOSTAT 1 A52 (CONTROL-BDC3 I B3 WHITE O P MOTOR,BLOWER BI9 MOTOR-WATER PUMP N - J46 JICK-IT BREAKER BLACK PUMP J46 JACK-OUTPUT LI (CIRCULATOR) J48 JACK-MOTOR,FRESH AIR BLOWER J49 JACK-MOTOR,VARIABLE SPEED K212 RELAY-FIELD HOOKUP LI3 (CHOKE-POWER n P46 (PLUG-OUTPUT ®® ®® CBWMV P48 PLUG-MOTOR,FRESH AIR BLOWER TB2 12ov id TBL9 12ev CONTROL P49 PLUG-MOTOR,VARIABLE SPEED re2 BBCB DLO orL IdIRRL BOX S5I SWITCH-DOOR INTERLOCK e - S105 (THERMOSTAT-ANTI-FREEZE 117744 5 - TI ITRANSFORMER,CONTROL SSI ncE TBI TERMINAL STRIP DOOR 24v TB2 ERMINAL STRIP-UNIT INTERLOCK LI 0 i i TBee TB7 TERMINAL STRIP Le FIELD CBB O m 0uu,LNG CIRCUIT TBI3 ERMINAL STRIP TB66 TERMINAL STRIP-FIELD HOOKUP TB67 F ,n, FIELD 0 r REFER TO FACTORY BLOWER SPEED TAP L 0\ 0 SELECTION CHART FOR BLOWER SPEED uu INFORMATION. TBI REMOVE JUMPER BETWEEN "DS" AND r _>Oc pe #� m HARMONYEZONINGISUUSEDTAT OR Ir -0e zv®M ____I----O� JUMPER "Yl" TO "Y2" IS FOR I r All SINGLE STAGE COOLING. REMOVE A2 I I I I 0WE ®- 4—® JUMPER FOR TWO STAGE COOLING. SlgnafureSla4e I I I I Tin ffi I BELT 0 L13 USED ON IHP ONLY THERMOSTAT I Ova I r I I -L -0R -Q O O ® FIELD SUPPLIED ACCESSORY WIRE. JJ J I A REMOVE 0 TO TB7-24 JUMPER FOR I I I I ———r—— HEAT PUMP APPLICATIONS. bbdbbb I D C R G W Y 1 m FOR HARMONY APPLICATIONS,REMOVE PIN •2(JP49) ON B3 BLOWER MOTOR. I I TAPE WITH ELECTRICAL TAPE TO PREVENT ELECTRICAL PATH. I C U J I _ ® TWO TERMINAL BLOCKS AND A RELAY ARE Y - J INDOOR / ' FACTORY PROVIDED FOR FIELD HOOKUPS u - - -- BLOWER B3 I MOTOR \ BLOWER SPEED TAP SELECTION OUTDOOR _/ BLOWER UNIT COIL COOL HEAT -24B-040 PIN I PIN 2 WARNING- -36B-070 PIN 3 PIN 4 ELECTRIC SHOCK HAZARD, CAN CAUSE INJURY OR DEATH. UNIT -36C-090 PIN 3 PIN 4 MUST BE GROUNDED IN ACCORDANCE WITH NATIONAL AND LOCAL CODES. A2 -60C-I00 PIN 4 PIN 4 NOTE- Slgna}ureStot' -60C-I20 PIN 4 PIN 4 IF ANY WIRE IN THIS APPLIANCE IS REPLACED,IT MUST BE REPLACED THERMOSTAT WITH WIRE OF LIKE SIZE,RATING,INSULATION THICKNESS AND TERMINATION ^ `n 9o-7,- - 551 9 9 Y ETC) IT/ I DOOR INNTTERLOCK TB7 I I I I I L _ — _—_— I LI f� p!� • BLACK TB2-120V-HOT 24 YELLOW ® I I I I 'r— m PINK I I I I L 0 Y TBI I I I I r-- - w I I I I ,® A52 (TB67 r' TBI _-1 II I I CD CO 0- g/ 0 O CB8Er , I i , `�<-v I I , \j jam,") I C © I I <w�° m ® � _ _ _ J I - <No AS105 ANTI-FREEZE W1 I -II THERMOSTAT al I r (2 YELLOW 9FACTORY FURNISHED © b <O).<-OO 1 FIELD INSTALLED TI <m‹-p 1 Fd.' . <N‹-° B 19 a TB7 <10� PUMP YELLOW PURPLE /N/ ,� Q (CIRCULATOR) © - /\ <-,", I ANDFIELD INSTALLEDEI GREEN/YELLOW GREEN GREEN ja�� GROUND PINK /M I I PURPLE I jN< I e r r e r r e r r i e r err I - LINE CLASSY III TAGE VOLTAGELFIELDT ALLED — — WIRING TBI3-120V NEUTRAL Q WHITE N LI3 if P49 12 3 4 5 6 7 8 9 10 11 12 13 14 15 16 POWER IL i\AL AL A\AL AL AL AL AL AL AL AL AL AL AL �7p.�� CHOKE 44a 1_ EOUIPMENT 5' • GROUND 4 4 • ain 21 • 1 4 • B3 Figure 12 RECEIVED Page 10 04/06/2018 505,547M ASPEN BUILDING DEPARTMENT Freeze-stat Operation Continuous Low Blower Option Refer to the blower speed chart located on the CBWMV IMPORTANT unit wiring diagram for factory set cooling, heating and low A (continuous) blower speeds. Systems using a cooling ther- mostat subbase may operate continuous blower(factory- Use of the freeze-stat feature is required in all installa- set to operate at 38% of second-stage cooling speed) tions using CBWMV units. through the FAN-ON switch of the thermostat. For continu- The CBWMV unit is equipped with a field-wired freeze- ous low blower with a system without a cooling subbase, a stat. The freeze-stat protects the CBWMV system from fan switching subbase may be used. freezing temperatures when the unit is installed in uncondi- Heating or cooling demand will cause blower to go to heat tioned areas. or cool speed. The factory-provided freeze-stat must energize the circu- Blower Speed Adjustments lator when water temperatures fall below 45°F. Freeze-stat wiring is shown in figure 13. Diagnostic LEDs RUN LED — Indicates a demand for blower operation in N Freeze-stat Field Wiring LI either the heating mode or continuous fan-only mode. ! RUN LED will not illuminate during a cooling demand. CFM LED—Indicates the CFM at which the unit is operat- ing. The light flashes once for approximately every 100 ____ __ _ _ _ CFM. For example, if the unit is operating at 1000 CFM, 0-0-�- DOOR CFM LED will flash 10 times. If the CFM is 1150, CFM LED NEUTRAL Y I INTERLOCK B19 9105 0-0 PUMP ANTI-FREEZE TBB, I will flash 11 full times plus one fast or half flash. FIELD FURNISHED THERMOSTAT IJ'L'iFIELD INSTALLEDAND INSTALLED FACTORY FURNISHED Ic'i At times the light may appear to flicker or glow. This takes place when the control is communicating with the motor TBz-izov HOT between cycles. This is normal operation. The appropriate speed according to application and CFM Figure 13 need is selected by moving jumper pins. BDC3 Variable Blower Control Board BDC3 Variable Speed Control Board CBWMV units are equipped with a variable speed motor O O 0 that is capable of maintaining a specified CFM throughout ° . ° JP1 o /o 0 0 /o the external static range.A particular CFM can be obtained JP1 o ° by positioning jumpers (COOL, HEAT, and ADJUST) on 15 PIN PLUG TO the BDC3 control board. The COOL and HEAT jumpers (BOARD OMOTOR) LENNOX are labeled 1, 2, 3, and 4. Each of the numbers corre- ACCESSORY II II sponds with an air volume (CFM) setting. The ADJUST RELAY CON- h J. jumper is labeled TEST, -, +, and NORM. The + and - pin TACTS Acc [1settings are used to add or subtract a percentage of the (DRIVTOOESOAK4v/IA ACCESSORY CFM selected. The TEST jumper is used to operate the RELAY) , motor in the test mode. The DELAY jumper controls ramp- OPERATIONAL ing profiles. SELECTOR\0 o NORM o 0 4 0 0 4 0 0 4 Figure 14 shows the BDC3 control board. Use tables 5 PINST 0 0 • 0 0 2 0 0 2 0 0 2 - g (AFFECTS 0 o - 0 02 0 0 2 0 02 through NO TAG to determine the correct air volume for BOTH ®TEST 1a�0 1 ®1 ®1 g HEATING AND ADJUST HEAT COOL DELAY M oe heat and cool speed taps. COMOL s> O O Diagnostic LEDs located on the BDC3 control board are provided to aid in identifying the units mode of operation. HEATING SPEED COOLING SPEED FAN DELAY DIAGNOSTIC Certain scenarios will arise depending on the jumper posi- SELECTOR PINS SELECTOR PINS SELECTOR PINS LEDS tions. Read through the jumper settings sections before adjusting blower speed. Refer to figure 14 for identification. Figure 14 RECEIVED Page 11 04/06/2018 cBAisvp ins BUILDING DEPARTMENT Jumper Settings For applications with the Harmony® Zoning System, the blower CFM volume is determined by the Harmony control center. The minimum blower speed is predetermined at A IMPORTANT 400 CFM for -CBWMV-24B-040 and 36B-070 series units and 600 CFM for CBWMV-36C-090, 60C-100, and Before changing jumper setting, make sure the motor 60C-120 series units. This speed is not adjustable. has completely stopped. Any jumper setting change will With the thermostat set for"Continuous Fan"and without a not take place while the motor is running. call for heating or cooling, the CBWMV will provide 38%of the COOL CFM selected. HEAT Pins — The HEAT jumper is used to determine Table 4 shows the factory blower speed tap settings for CFM heating. These jumper selections are activated only CBWMV series units. These settings are for nominal ton- when W1 is energized. (There is a fixed 45 seconds ON nage match-ups with the CBWMV. When matched with and 30 seconds OFF delay on a W call.) other sizes, it is recommended that the CFM be adjusted DELAY Pins—The DELAY jumper is used to set the spe- approximately to 400 CFM per ton. cific motor fan operation during cooling mode. Depending on the application, one of four options may be chosen by Table 4 moving the jumper to the appropriate set of pins. Factory Blower Speed Tap Settings #1 Pins Jumpered — CBWMV Speed Tap Selection Blower A Motor runs at 100% until demand is satisfied. Coil Cool Pin Heat Pin Adjust Delay A B -24B-040 1 2 NORM 4 -36B-070 3 4 NORM 4 OFF OFF -36C-090 3 4 NORM 4 B Once demand is met, motor ramps down to stop. -60C-100 4 4 NORM 4 -60C-120 4 4 NORM 4 #2 Pins Jumpered — To change jumper positions, gently pull the jumper off the A Motor runs at 100% until demand is satisfied. pins and place it on the desired set of pins. The following A B C section outlines the different jumper selections available and conditions associated with each one. Refer to figure OFF OFF 14. B Once demand is met, motor runs at 100% for 45 After the CFM for each application has been determined, seconds. Then, the jumper settings must be adjusted to reflect those given C ramps down to stop. in tables 5 through NO TAG. From the tables, determine NOTE-Blower OFF DELAY also applies during heat which row of CFM volumes most closely matches the de- pump operation sired CFM. Once a specific row has been chosen (+, NOR- MAL, or-), CFM volumes from other rows cannot be used. #3 Pins Jumpered — Below are descriptions of the jumper selections. A Motor runs at 82% for approximately 7-1/2 min- utes. ADJUST Pins—The ADJUST pins allow the motor to run ina If demand has not been satisfied after 7-1/2 m at normal speed, approximately 10% higher, or approxi- minutes, °/o until demand is satisfied. mately 10% lower than normal speed. Tables 5 through B motor runs at 100 NO TAG gives three rows (+, NORMAL, and -)with their A B, C respective CFM volumes. Notice that the normal adjust- ment setting for heat speed position#3 is 1070 CFM.The+ OFF / OFF adjustment setting for that position is 1180 CFM and for the C Once demand is met, motor ramps down to stop. -adjustment setting is 940 CFM. After the adjustment set- ting has been determined, chose the remainder speed #4 Pins Jumpered — jumper settings from those offered in the table in that row. A Motor runs at 50% for 30 seconds. The TEST pin is available to bypass the BDC3 control and B Motor then runs at 82% for approximately 7-1/2 run the motor at approximately 70%to test that the motor is minutes. If demand has not been satisfied after operational. This is beneficial primarily in troubleshooting. 7-1/2 minutes. G must be energized for motor to run. C Motor runs at 100% until demand is satisfied. D Once demand is met, motor runs at 50% for 30 COOL Pins—The COOL jumper is used to determine the seconds. Then, CFM during either 1) cooling or 2) heat pump operation without a W1 call for electric heat.These jumper selections A B C, D E are activated for cooling when Y1 and/or Y2 and DS termi- � e� VED nals in the CBWMV unit are energized and for heating OFF when Y1 and/or Y2 is energized. E ramps down to stop. Page 12 04/06/2018 505,547M ASPEN BUILDING DEPARTMENT Table 5 CBWMV-24B-040 Blower Performance 0 through 0.80 in.w.g.External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT"Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 1 2 3 4 1 1 2 3 4 1 1 2 3 4 + 820 990 1180 1340 610 770 930 1010 880 1120 1340 1440 1 NORM 750 900 1070 1230 560 700 830 910 800 1000 1200 1300 — 670 810 940 1080 510 630 750 810 720 900 1080 1170 CBWMV-36B-070 Blower Performance 0 through 0.80 in.w.g.External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT"Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 2 3 1 4 1 2 1 3 4 1 2 1 3 4 + 790 980 1140 1310 590 745 895 975 850 1090 1300 1430 1 NORM 730 870 1040 1190 545 680 805 890 775 990 1190 1280 — 640 770 920 1070 490 600 725 780 700 870 1065 1150 CBWMV-36C-090 Blower Performance 0 through 0.80 in.w.g.External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT"Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 2 3 1 4 1 2 1 3 4 1 2 1 3 4 + 820 1000 1180 1340 620 770 930 1010 890 1130 1340 1450 1 NORM 760 900 1070 1220 570 700 830 910 800 1020 1220 1310 675 810 950 1100 520 630 760 810 720 900 1100 1180 CBWMV-60C-100 Blower Performance 0 through 0.80 in.w.g.External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT"Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 2 3 1 4 1 2 3 1 4 1 2 3 1 4 + 1500 1700 1880 2100 1110 1250 1380 1530 1540 1760 1970 2200 1 NORM 1370 1540 1720 1920 1000 1130 1250 1380 1400 1600 1800 1980 1250 1380 1540 1720 930 1040 1130 1260 1270 1420 1600 1780 CBWMV-60C-120 Blower Performance 0 through 0.80 in.w.g.External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT"Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 2 3 14 1 2 3 14 1 2 3 14 + 1510 1720 1900 2120 1100 1250 1400 1560 1570 1800 2000 2200 1 NORM 1380 1560 1740 1920 990 1130 1260 1400 1410 1620 1820 2020 — 1240 1380 1540 1720 930 1020 1130 1260 1260 1440 1620 1810 1 Factory default jumper setting. NOTES- The effect of static pressure and filter resistance is included in air volumes shown. First stage COOL is approximately 70%of the same second stage COOL speed position. Continuous Fan Only speed is approximately 38%of the same second stage COOL speed position. Harmony IIITM Zoning System applications-Minimum blower speed: 250 cfm for-24B-40,-36B-070,-36C-090. 450 cfm for-60C-100. 380 cfm for 60C-120. Maximum air volume is the same as second-stage cool position. Applications with single sided inlets will reduce the air volume by approximately 4%on B-size units and 5%on C-size units. RECEIVED Page 13 04/06/2018 CB) r"LRmS BUILDING DEPARTMENT Initial Air Purging Refer to the speed selection chart on unit wiring diagram. After all plumbing connections have been made, leak NOTE-To check for proper CFM, take the reading exter- nal tested and flushed, the water heating device is ready to be ea the unit. The coil must be dry when you take the r filled with water and purged of air. Air bleeder valves are reading. provided as a convenience for installations that are not Annual Service equipped with purge manifolds. 1. Make sure electrical power and gas supply to system A WARN I N G are OFF. Electric shock hazard. Can cause injury 2. Remove CBWMV coil section access panel. or death. Before attempting to perform 3. Remove cap from highest air bleed valve and depress any service lir er maintenance, turn the valve stem until water is released.This may be done with electrical power to unit OFF at disconnect a refrigerant style hose. See figure 15. sppy es). Unit may have multiple power suupplies. 4. Replace cap on valve and access panel. At the beginning of each heating season, system should be 5. Apply electrical power and gas supply to the system. checked as follows by a qualified service technician: 6. Follow the System Start-Up section to operate the sys- Electrical tern. Complete purging of air after unit has gone 1. Check all wiring for loose connections. through initial start-up. 2. Check for correct voltage at CBWMV unit(unit operat- ing). 3. Check to see that blower is operating. Air Bleed Valve Location Blower 1. Check and clean blower wheel. Mil 2. Motors are pre-lubricated for extended life; no further �N lubrication is required. 'S Freeze-stat - Verify that the freeze-stat functions. - Service Filters 4 Filters must be cleaned or replaced when dirty to assure `/� proper unit operation. - `� I Winterizing CBWMV Water Coil `�A If unit is installed in an unconditioned space, the piping be- t!, tween the CBWMV unit and the water heating device should be insulated. If power is removed from the unit,wa- ter must be drained from the system to prevent freezing. SHOWN '/ Repair Parts List WITH CAP ON The following repair parts are available. When ordering parts, include the complete unit model number listed on the �� unit rating plate of each piece of equipment. ��% ♦ Cabinet Parts • Blower Access Panel �i • Coil Access Panel Figure 15 Hot Water Coil Parts • Coil Replacement Kit Blower Part System Adjustments • Blower Wheel • Blower Motor Timed-ON and Timed-OFF Delays • Blower Housing The 45-second timed-ON delay and the 30-second timed- Electrical Parts OFF delay for heating (time that the blower operates after the heat demand has been satisfied) is not adjustable. • BDC3 Board • Blower Speeds Transformer Select the blower speed by moving the pins on the variable • Circuit Breaker, 24VAC RECEIVED speed control board. See figure 14. • 3PDT Relay Page 14 04/06/2018 505,547M ASPEN BUILDING DEPARTMENT Troubleshooting: Continuous Fan Sequence of Operation CONDITIONS: Power On Normal Operation LED: Steady Flash Thermostat(S1)Calls for Continuous Fan,G-Only NO i Check for 24 Volts Between'G'and C at Al 5 Terminal Strip YES 1 Blower Operates at the Continuous Fan Speed NO Selected by COOL Jumper and ADJUST Jumper ► Check for 24 Volts Between Pins 3 and 15 on J49 Positions on the BDC3 Control(A52) - YES 4, RUN Light on BDC3 Control(A52)illuminates to Indi- cate a Continuous Fan Call YES 4, CFM Light on A52 Indicates Blower CFM Selection with 100CFM/Blink YES 4 Thermostat(S1)Continuous Fan Demand Satisfied YES 11, Blower Off [roubleshooting: Heating Sequence of Operation CONDITIONS: Power On Normal Operation LED: Steady Flash Thermostat(S1)Calls for Heat NO Check for 24 Volts Between YES W and C at A52 Terminal Strip V Fixed blower-ON delay(45-second)complete Blower Operates at the Heating Speed Selected by HEAT Jumper and ADJUST Jumper Positions on NO > Check for 24 Volts Between Pins 3 and 2 on J49 the BDC3 Control(A52) YES CFM Light on A52 Indicates Blower Speed Selection with 100CFM/Blink YES Thermostat(S1)Demand Satisfied YES 1 30 Second Blower Off Delay Fixed Complete YES 1 Demand for Heat Satisfied RECEIVED Page 15 04/06/2018 cBAins BUILDING DEPARTMENT Troubleshooting: Cooling Sequence of Operation CONDITIONS: Power On Normal Operation LED: Steady Flash Thermostat(S1)Provides 24 Volt Cooling Call to In- NO door Blower(B3) t Check for 24 Volts Between Y and C at Al 5 Terminal Strip YES Blower(B3)Operates at the 2nd Stage NO Check for 24 Volts 2 Stage Condensing Unit? NO ► Cooling Speed Determined by COOL, ► Between Pins 14 and DELAY and ADJUST Jumper Positions on 3 on J49 YES the BDC3 Control(A52) V YES Blower(B3)Operates at the 1st Stage Cooling Speed CFM Light on A52 Indicates Blower CFM Determined by COOL,DELAY and ADJUST Jumper NO Selection with 100CFM/Blink Positions on the BDC3 Control(A52) CFM Light on A52 Indicates Blower CFM Selection with YES 100CFM/Blink Thermostat(S1)Demand Satisfied YES YES Check for 24 Volts Between Y Blower Shuts Off According to the DELAY and C on A15 Terminal Strip Jumper Position on the BDC3 Control (A52) Check for 24 Volts Between Pins 6 and 3 on J49 YES Demand for Cooling Satisfied V A 0-First Stage Demand for Cooling Satisfied? NO No Thermostat(S1)Calls for Check for 24 Volts Between Y2 on 2nd Stage Cooling TB1 and C on A15 Terminal Strip YES YES Blower Shuts Off According to the DELAY Jumper Blower Operates at the 2nd NO Check for 24 Volts Between Pins 14 Position on the BDC3 Control(A52) Stage Cooling Speed Deter- and 3 on J49 mined by COOL,DELAY and YES + ADJUST Jumper Positions Demand for Cooling Satisfied on the BDC3 Control(A52) YES CFM Light on A52 Indi- cates Blower CFM Selec- tion with 100CFM/Blink YES 2nd Stage Thermostat (S1)Demand Satisfied YES Blower Returns to 1st Stage Cooling Speed RECEIVED Page 16 04/06/2018 505,547M ASPEN BUILDING DEPARTMENT WATER HEATING / BOILERS CBWMV LENNOX Residential Hot Water Heat Air Handler PRODUCT SPECIFICATIONS Bulletin No.210434 June 2014 Supersedes January 2013 LEN 10X FC-1=CBWMV-24B-040 FC-2=CBWMV-24B-040 FC-3=CBWMV-60C-120 Heating Capacity - 23,700 to 220,000 Btuh ALL UNITS Nominal Add-On Cooling - 2 to 5 Tons MODEL NUMBER IDENTIFICATION CBWMV - 24B - 070 - 3 Unit Type Minor Revision Number CBW=Air Handler with Hot Water Coil Configuration Nominal Water Coil Heat M=Multi-Position 040=40,000 Btuh 070=70,000 Btuh 090=90,000 Btuh Blower 1 100=100,000 Btuh V=Variable Speed Blower 120=120,000 Btuh Nominal Cooling Capacity-Tons RECEIVED 024=2 tons Cabinet Width 036=3 tons B= 17-1/2 in. 060=5tons C=21 in. 04/06/2018 ASPEN BUILDING DEPARTMENT FEATURES CONTENTS Blower Data 9 Dimensions 6 Dimensions- Furnace/Coil Combined Combinations 8 Electrical Data 5 Features 2 Field Wiring 5 0% Heating Performance 10 Installation Clearances 5 Model Number Identification 1 Optional Accessories 5Q � Optional Accessory Dimensions /-4041 Specifications 5 WARRANTY % ----------------------- All covered components - Limited warranty for ten rt years limited warranty in residential applications. • • i, Refer to Lennox Equipment Limited Warranty certificate included with equipment for details. w 4 [, SEQUENCE OF OPERATION CBWMV includes supply air blower, hot water coil, and blower control.A circulating pump can be ordered extra for field installation. After a 45-second (fixed)timed-on delay the blower energizes at heating speed. After a 30-second (fixed)timed-off delay the supply air blower shuts off. HEATING SYSTEM APPROVALS Q Hot Water Coil Units certified by CSA International. Corrugated/lanced aluminum fins. Blower data from unit tests conducted in Lennox Seamless corrosion resistant copper tubes. Laboratory air test chamber. Fin collars grip tubing for maximum contact area. APPLICATION Flared shoulder tubing connections and silver soldering CBWMV can be used with properly sized gas-fired or provides tight, leakproof joints. oil-fired water heating devices. Factory tested under high pressure. Cannot be used with potable water. Entire coil accessible for cleaning. Supply air blower moves the return air past the coil to extract the heat and then distribute the heated air Freezestat throughout the conditioned space. Protects system from freezing temperatures when unit is installed in unconditioned areas. CBWMV is a multi-position (upflow, downflow, or horizontal) blower/hot water coil unit. Thermostat automatically energizes circulating pump when water line temperature falls below 45°F. Lennox add-on indoor coil with remote air conditioning unit, air cleaners, automatic humidifier, and all Lennox Optional Accessories Indoor Air Quality products can easily be added for a Circulating Pump complete all season system. Bronze construction, Non-metallic impeller with Carbon Zoning Applications bearings. Units may be used with certain zoning systems. Self lubricating. Zone control panel must be able to interface and Impedance protected. 4-a ,,;, , it communicate with the variable speed blower motor in Motor and impeller removable as single unit for the unit. Lennox Harmony I I I TM Zoning System has this servicing. 0 4/0 6/2 018 capability. ASPEN CBWMV /Page 2 BUILDING DEPARTMENT FEATURES CABINET Air Filter and Rack Kit for Upflow Side Return Air 0 Heavy gauge cold rolled steel constructed. Applications - Not for use with RAB Return Air Base Pre-painted cabinet finish. Washable or vacuum cleanable polyurethane frame type filter and external side return air rack available for Foil faced fiberglass insulation on hot water coil access field installation. door panel, side panels and on back panel reduces cabinet temperatures. Available in single and ten pack kits. Black mat faced fiberglass in blower compartment Rack has filter door for easy filter servicing. assures quiet operation. Flanges on rack allow easy duct connection. Complete service access by removing hot water coil Field installs on either side of unit cabinet. See section and blower compartment access panels. dimension drawing. Blower assembly completely removable for easy EZ Filter Base for Upflow Bottom Return Air servicing. Applications Blower deck rails angle down for easy blower removal. Hinged door with thumbscrew for easy filter access. Electrical inlets in both sides of the cabinet. Uses standard size filters (field provided). Safety interlock switch automatically shuts off power to BLOWER unit when blower compartment access door is removed. Variable Speed Blower Motor Return air entry on either side or bottom of cabinet. Variable speed motor(VSM) maintains specified air CBWMV is applicable to upflow, horizontal, or downflow volume from 0 though 0.80 in. w.g. static range. installations. Gradual acceleration and deceleration of variable speed Field Make-up Box blower motor when starting and stopping over a specific Furnished for line voltage wiring. time frame results in extremely quiet operation. Box may be installed on either side of CBWMV cabinet. Variable speed operation is achieved by the use of an ECM (Electronically Commutated Motor) motor. Cabinet- continued Motor is controlled by Electronic Blower Control. Optional Accessories Motor is resiliently mounted. Horizontal Support Frame Kit When units are used with Harmony III TM Zoning System, Provides support of unit in horizontal applications. blower motor operates from predetermined minimum to Consists of(2) 1 x 1-1/2 x 32-5/8 in. and (2) 1 x 3 x maximum air volumes to satisfy zone requirements. 53-7/8 in. painted heavy gauge cold rolled steel support channels with assembly and suspending holes. 0 Variable Speed Blower Bolts and nuts furnished for field assembly. Each blower assembly statically and dynamically balanced. Suspending rods must be field provided. Change in blower speed is easily accomplished by RAB Return Air Base simple jumper pin position change on Electronic Blower "C" and "D"width bases required with 60C models with Control. air volumes over 1800 cfm in up-flow applications when Blower assembly completely removable for easy only one side return is used. servicing. "B"width base is not required but may also be used to See blower performance tables. provide clearance in certain applications (if required). Cabinet is pre-painted steel to match the furnace. See Dimension Drawing. Air Filter and Rack Kit for Horizontal Return Air (End)Applications Washable or vacuum cleanable polyurethane frame type filter and external end return air rack available for field installation. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. See dimension drawing. RECEIVED 04/06/2018 ASPEN Bufrte Eil fOENT FEATU RES CONTROLS Optional Accessories 0 Electronic Blower Control ComfortSense°7000 Touchscreen Thermostat Interfaces variable speed motor with thermostat. Electronic 7-day, universal, multi-stage, programmable, Controls evaporator humidity by controlling blower and touchscreen thermostat. compressor speed on two-stage outdoor units. 4 Heat/2 Cool. Two COOL speeds and one HEAT speed (with four Auto-changeover. o nnoF different air volume selections for each)are made by Controls humidity during � '—"—' sc° simple jumper pins on board. cooling mode. ADJUST jumper pin allows approximately 10% higher, Offers enhanced capabilities normal, or 10% lower motor speed selection within including humidification / HEAT and COOL speeds selected for fine tuning the air dehumidification /dewpoint volume. measurement and control, Humiditrol®control, and DELAY jumper pin allows selection blower motor de- equipment maintenance reminders. humidification profiles during cooling mode. Easy-to-use, menu driven thermostat with a back-lit, Option 1 - Motor runs at 100% of capacity until demand LCD touchscreen. met. Once demand is met, motor ramps down to stop. Remote outdoor temperature sensor(optional)allows Option 2 - Motor runs at 100% of capacity until demand the thermostat to display outdoor temperature. Required is satisfied. Motor runs at 100% of capacity for 60 in dual-fuel and Humiditrol®applications. seconds then ramps down to stop. See the CornfortSense° 7000 Product Specifications Option 3- Motor runs at 82% of capacity for bulletin in the Controls section for more information. approximately 7-1/2 minutes. If demand is not satisfied, motor runs at 100% capacity until demand is satisfied. Thermostat Once demand is met, motor ramps down to stop. See Thermostat bulletins in Controls section and Option 4 - Motor runs at 50% capacity for 30 seconds, Lennox Price Book for a complete list of thermostats. then 82% capacity for approximately 7-1/2 minutes. If demand is not satisfied, motor runs at 100% capacity until demand is met. Once demand is met, motor runs at 50% capacity for 30 seconds, then ramps down to stop. Control has two diagnostic indicator lights, "CFM" and "RUN", to assist in servicing. Accessory relay terminals provide connections for power humidifiers or electronic air cleaners. Control is factory installed in the unit control box. 24 Volt Transformer Furnished in CBWMV control box. RECEIVED 04/06/2018 ASPEN CBWMV /Page 4 BUILDING DEPARTMENT SPECIFICATIONS Model No. CBWMV CBWMV CBWMV CBWMV CBWMV -24B-040 -36B-070 -36C-090 -60C-100 -60C-120 Heating Nominal heating capacity-Btuh 40,000 70,000 90,000 100,000 120,000 Performance ' Temperature rise range-°F 32- 101 45- 125 51 - 125 41 - 113 45- 125 Indoor Wheel nominal diameter x width-in. 10 x 8 10 x 8 10 x 8 11-1/2 x 10 11-1/2 x 10 Blower Blower motor output-hp 1/2 1/2 1/2 1 1 Tons of add-on cooling 2-3 2-3 2-3 3.5-5 3.5-5 Heating Heating capacity range-Btuh 23,700- 30,300- 31,400- 49,600- 55,000- Coil 84,700 123,800 138,400 181,700 220,000 Net face area-sq.ft. 3.83 3.83 4.33 4.33 4.33 Tube diameter&no. of rows-in. 3/8- 1 3/8-2 3/8-2 3/8-2 3/8-3 Fins per inch 16 16 16 16 16 Required pump flow rate for coil capacity rating-GPM 6 6 9.5 9.5 9.5 Water Line Connections Inlet 3/4 3/4 1 1 1 (sweat)- in. I.D. Outlet 3/4 3/4 1 1 1 Shipping Data lbs.- 1 package 127 144 157 157 165 ELECTRICAL DATA Electrical characteristics 120 volts-60 hertz- 1 phase 2 Maximum Overcurrent Protection 15 15 15 20 20 Minimum Circuit Ampacity 10.2 10.2 10.4 16.8 16.8 OPTIONAL ACCESSORIES (ORDER SEPARATELY) 3 Air Filter& Horizontal (end)-in. 87L96 87L97 Rack Kit 18 x 25 x 1 20 x 25 x 1 in. Side Return-in. Single 44J22 or Ten Pack(66K63)-(1) 16 x 25 x 1 Circulating Catalog Number 99K69 99K69 53J76 53J76 53J76 Pump Motor output-hp 1/40 1/40 1/25 1/25 1/25 Capacity-U.S. GPM 0-10 0-10 0-14 0-14 0-14 Pressure drop thru coil @ rated flow-psi 3 3 3 3 3 ComfortSense®7000 Thermostat Y2081 Y2081 Y2081 Y2081 Y2081 Remote Outdoor Sensor(for dual fuel and Humiidtrol®) X2658 X2658 X2658 X2658 X2658 EZ Filter Base Catalog Number 73P56 73P57 Dimensions-H x W x D-in. 4 x 17-5/8 x 28-5/8 4 x 21-5/8 x 28-5/8 Size of field provided filter-in. 16 x 25 x 1 20 x 25 x 1 Horizontal Support Frame Kit 56J18 56J18 56J18 56J18 56J18 RAB Return Air Base 98M60 98M58 1 Minimum temperature rise is based off 140°F entering water temperature and the maximum heating air volume.Maximum temperature rise is based off 200°F entering water temperature and the minimum heating air volume using the Harmony III TM Zoning System. 2 HACR type breaker or fuse. 3 Cleanable polyurethane frame type filter. FIELD WIRING INSTALLATION CLEARANCES r DISCONNECT, CBWMV Upflow/ CBWMV Horizontal I SWITCH I Downflow L (by other) J Q Sides 0 inches (0 mm) 0 inches(0 mm) CBWMV Rear 0 inches (0 mm) 0 inches(0 mm) UNIT Q Top 0 inches (0 mm) ' 0 inches(0 mm) r— --i Front 2 0 inches(0 mm) 2 0 inches(0 mm) OPTIONAL I THERMOSTAT I Floor Combustible 0 inches(0 mm) A - Two wire power with ground NOTE-Termination location must conform to the met �e��c n B - Three wire control voltage(Heating Only) National Standard(ANSI-Z223.1)National Fu o I Four wire control voltage(Cooling) Sta dard of Canada CAN/CGA-149.1,and CAN/ A-149.2"Installation g Code for Gas Burning Appliances". 0//�� //�GG // Five wire control voltage (2-Stage Cooling) 'Line contact installation permissible between jacket top Alis0 Wtt ilc 1 8 - Field wiring not furnished - joists All wiring must conform to NEC or CEC and local electrical codes. 2 Front clearance for alcove installations is 30 in. ASPEN B U I CeittelbEIFFAIFVENT DIMENSIONS - INCHES (MM) 1 NOTE -Single side inlet applications result in approximately 4% reduction of air volume on B-size units and approximately 5% reduction of air volume on C-size units. WATER INLET I SUPPLY AIR 2 Optional External Side Return Air Filter Kit is not for use with OPENING the optional RAB Return Air Base. F WATER OUTLET D 4 2 OPTIONAL 23-3/4(603) EXTERNAL SIDE RETURN 25(635) 10 AIR FILTER KIT TOP VIEW (Either Side) A 28-1/2 (724) 9/16 h411-01— B +9/16(14) 1(4994) (14) ALTERNATE WATER INLET 1 o o (Left Side Only) 1-1/4itoil (32) t 1-3/4 10-1/2 (44) (267) ALTERNATE 2 OPTIONAL WATER OUTLET EXTERNAL (Right Side Only) V SIDE RETURN AIR FILTER KIT 2 -*— ELECTRICAL INLET (Either Side) (51) (Either Side) 40 °o° (1016) —f 0 I 0 14-3/4 102 584) F (375) ( )1 ( 16 OPTIONAL 14 (406) I RETURN CUTOUT (356) I I (Either Side) AIR FLOW L _JI r 1-15/116(49) 4 5/8 (16) 23-1/2597 ...] -.IL. C 3/4(19) ( ) 3/4(19) Bottom Return 4-1/4 Bottom Return Air Opening (108) Air Opening FRONT VIEW SIDE VIEW A B C D E F G Model No. in. mm in. mm in. mm in. mm in. mm in. mm in. mm CBWMV 24B 040 17-1/2 446 16-3/8 416 16 406 1-1/2 38 1-3/4 44 8 203 2 51 CBWMV-36B-070 CBWMV-36C-090 CBWMV-60C-100 21 533 19-7/8 454 19-1/2 495 2 51 2-1/2 64 9-1/2 241 1-1/2 38 CBWMV-60C-130 RECEIVED 04/06/2018 ASPEN CBWMV /Page 6 BUILDING DEPARTMENT OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) HORIZONTAL FILTER KIT 24-3/4 1-1/4(32) rill5/8(629) 1 i liml(16) 5/8 NI (16) B RETURN I A AIR OPENING AIR FLOW 23-1/2_11,. 5/8 (597) (16) T ' I_I AIR FILTER 5/8 4 (Furnished) (16) SIDE VIEW FRONT VIEW A B Catalog Number - inch mm inch mm 87L96 18 457 16-3/4 425 87L97 21 533 18-3/4 476 RAB RETURN AIR BASE (Upflow Applications Only) — 4 1.411— 1 23(584) f op J Il (102)1 Overall 1 Minimund 14 (Maximum) 11 (279) (356) 2 Maximu 1 22-7-16 1 Unit side return air 141 3.56 (570) AIR FLOW AIR HANDLER L Opening ' )J Overall lirFRONT 11 (Maximum) 5-5/8 SIDE RETURN 7-1/4(184) (143) AIR OPENINGS _t_ 4 (Either Side) _ ► 14 23(584) 3/4 I� OPTIONAL RAB 17-1/2(446) RAB-B(98M60) RETURN AIR BASE (19) 21 (533) RAB-C (98M58) �22) -4 27-5/8(702) 1 SIDE VIEW FRONT VIEW NOTE-Optional Side Return Air Filter Kits are not for use with RAB Return Air Base. 1 Both the unit return air opening and the base return air opening must be covered by a single plenum or IAQ cabinet. Minimum unit side return air opening dimensions for units requiring 1800 cfm or more of air(W x H):23 x 11 in.(584 x 279 mm). The opening can be cut as needed to accommodate plenum or IAQ cabinet while maintaining dimensions shown. Side return air openings must be cut in the field.There are cutting guides stenciled on the cabinet for the side return air opening.The size of the opening must not extend beyond the markings on the furnace cabinet. 2 To minimize pressure drop,the largest opening height possible(up to 14 inches)is preferred. NOTE-Optional Side Return Air Filter Kits are not for use with RAB Return Air Base. RECEIVED 04/06/2018 ASPEN BUIDIMEI ENT DIMENSIONS - INCHES (MM) - FURNACE/COIL COMBINED COMBINATIONS UPFLOW POSITION UPFLOW POSITION Cased Uncased (CX34 cased only) \/ t Model No A B A B �I 11 A in. mm in. mm in. mm in. mm CX34-18/24B-6FC33-24B / \ \� CX34-18/24C-6FC33-24C 16-1/2 419 56-1/2 1435 13-7/8 352 53-7/8 1368 CX34-25B-6F C33-25B 19-1/2 495 59-1/2 1511 15-7/8 403 55-7/8 1419 / B CX34-30B-6F C33-30B CX34-30C-6F C33-30C 20-1/2 521 60-1/2 1537 17-3/4 451 59-3/4 1467 40010 N 40 CX34-31B-6F C33-31B 23-1/2 597 63-1/2 1613 20-1/4 514 60-1/4 1530 , (1016) CX34 366 6F C33-36B 24-1/2 622 64-1/2 1638 21-7/8 556 61-7/8 1572 CX34-36C-6F C33-36C 24-1/2 622 64-1/2 1638 21-1/4 540 61-1/4 1556 CX34-38B-6F C33-38B 24-1/2 622 64-1/2 1638 22 559 62 1575 CX34-42B-6F C33-42B 24-1/2 622 64-1/2 1638 21-7/8 556 61-7/8 1572 DOWNFLOW POSITION CX34-43B-6F C33-43B 28-1/2 724 68-1/2 1740 26-1/4 667 66-1/4 1683 CX34-43C-6F C33-43C 28-1/2 724 68-1/2 1740 25-3/4 654 65-3/4 1670 IIIC CBWMV Wi C33-44C 24-1/2 622 64-1/2 1638 21-1/2 546 61-1/2 1562 dth CX34-44/48B-6FC33-48B 24-1/2 622 64-1/2 1638 22-1/8 562 62-1/8 1578 / A CX34-44/48C-6FC33-48C 24-1/2 622 64-1/2 1638 21-1/2 546 61-1/2 1562 \� CX34-49C-6F C33-490 29-1/2 749 70-1/2 1791 28-1/2 724 68-1/2 1740 CX34-50/60C-6FC33-50/60C27-1/2 699 67-1/2 1715 24-3/4 629 64-3/4 1645 40 CX34 62C 6F C33-62C 32-1/2 826 72-1/2 1842 30-5/8 778 70-5/8 1793 (1016) Overall Height DOWNFLOW POSITION ° I Model Coil Width Furnace Coil Height Overall Width Height O 1 Number in. mm in. mm in. mm in. mm \ i 1 Coil ice/ Height CR33-24B-F 17-1/2 446 17-1/2 446 13-1/4 337 53-1/4 1353 V CR33- B-F 17-1/2 -1/8 1/8 � CR33-30/36C30/36 -F 17 211/2 446 533 21 533446 1616-1/8 410410 56-1/856 14261426 1 NOTE—Downflow applica- tions�� CR33-48B-F 21 533 171/2 446 20 508 60 1524 tions with add—on cooling coil Coil requirefleld—fabricatedtransi-tions to provide adequate CR33-48C-F 21 533 21 533 20 508 60 1524 Width clearance for servicing/remov- CR33-50/60C-F 24-1/2 622 21 533 23-5/8 600 53-5/8 1362 ing the cooling coil without cutting the water lines. See Installation Instructions. HORIZONTAL HORIZONTAL POSITION Model A B Number in. mm in. mm B 40 CH33-25B-2F (1016) CH33-31 B-2F CH33-36B-2F CH33-36C-2F 26-1/2 673 66-1/2 1689 A L2. 01 CH33-42B-2F CH33-43C-2F // CH33-48C-2F /// I1!11 CH33-43B-2F r, D CH33 44/48B 2F ��� ���� CH33 49C 2F 31-1/2 800 71-1/2 1816 r II CH33 50/60C 2F `� � 04/06/2018 i ASPEN CBWMV /Page 8 BUILDING DEPARTMENT BLOWER DATA CBWMV-24B-040 Blower Performance 0 through 0.80 in.w.g. External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT" Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 1 2 3 4 ' 1 2 3 4 ' 1 2 3 4 + 820 990 1180 1340 610 770 930 1010 880 1120 1340 1440 ' NORM 750 900 1070 1230 560 700 830 910 800 1000 1200 1300 670 810 940 1080 510 630 750 810 720 900 1080 1170 CBWMV-36B-070 Blower Performance 0 through 0.80 in.w.g. External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT" Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 2 3 14 1 2 13 4 1 2 13 4 + 790 980 1140 1310 590 745 895 975 850 1090 1300 1430 ' NORM 730 870 1040 1190 545 680 805 890 775 990 1190 1280 640 770 920 1070 490 600 725 780 700 870 1065 1150 CBWMV-36C-090 Blower Performance 0 through 0.80 in.w.g. External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT" Speed-cfm First Stage"COOL" Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 2 3 14 1 2 13 4 1 2 13 4 + 820 1000 1180 1340 620 770 930 1010 890 1130 1340 1450 1 NORM 760 900 1070 1220 570 700 830 910 800 1020 1220 1310 675 810 950 1100 520 630 760 810 720 900 1100 1180 CBWMV-60C-100 Blower Performance 0 through 0.80 in.w.g. External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT" Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 2 3 14 1 2 3 14 1 2 3 14 + 1500 1700 1880 2100 1110 1250 1380 1530 1540 1760 1970 2200 1 NORM 1370 1540 1720 1920 1000 1130 1250 1380 1400 1600 1800 1980 1250 1380 1540 1720 930 1040 1130 1260 1270 1420 1600 1780 CBWMV-60C-120 Blower Performance 0 through 0.80 in.w.g. External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT" Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 2 3 ' 4 1 2 3 '4 1 2 3 ' 4 + 1510 1720 1900 2120 1100 1250 1400 1560 1570 1800 2000 2200 ' NORM 1380 1560 1740 1920 990 1130 1260 1400 1410 1620 1820 2020 1240 1380 1540 1720 930 1020 1130 1260 1260 1440 1620 1810 1 Factory default jumper setting. NOTES-The effect of static pressure and filter resistance is included in air volumes shown. First stage COOL is approximately 70%of the same second stage COOL speed position. RECEIVED Continuous Fan Only speed is approximately 38%of the same second stage COOL speed position. Harmony III TM Zoning System applications-Minimum blower speed: 250 cfm for-24B-40,-36B-070,-36C-090. 450 cfm for-60C-100. 0 4/0 6/2 018 380 cfm for 60C-120. Maximum air volume is the same as second stage cool position. ASPEN with single sided inlets will reduce the air volume by approximately 4%on B-size units and 5%on C-size units. BUIL I "6E' ?1 ENT HEATING PERFORMANCE CBWMV-24B-040 HEATING OUTPUTS NOTE-Capacities in shaded area require Harmony IIITM Zoning System to reach the air volumes listed Air Heating Outputs At Various Water Temperatures (Btuh) Volume(cfm) 140°F 150°F 160°F 170°F 180°F 190°F 200°F 400 23,700 26,900 30,100 33,500 36,700 39,900 43,100 500 27,400 31,100 34,800 38,800 42,500 46,200 49,900 600 30,700 34,800 38,900 43,500 47,600 51,700 55,900 700 33,600 38,100 42,600 47,600 52,200 56,700 61,200 800 36,200 41,000 45,900 51,400 56,300 61,100 66,000 900 38,500 43,700 48,800 54,800 60,000 65,200 70,400 1000 40,700 46,100 51,600 57,900 63,400 68,900 74,400 1100 42,700 48,400 54,100 60,700 66,500 72,300 78,100 1200 44,500 50,400 56,400 63,400 69,400 75,500 81,500 1300 46,200 52,400 58,500 65,900 72,100 78,400 84,700 CBWMV-36B-070 HEATING OUTPUTS NOTE-Capacities in shaded area require Harmony IIITM Zoning System to reach the air volumes listed Air Heating Outputs At Various Water Temperatures (Btuh) Volume(cfm) 140°F 150°F 160°F 170°F 180°F 190°F 200°F 400 30,300 34,400 38,500 42,700 46,800 50,900 54,900 500 36,200 41,100 45,900 51,100 56,000 60,900 65,700 600 41,500 47,100 52,600 58,700 64,300 69,900 75,500 700 46,300 52,500 58,700 65,600 71,800 78,100 84,300 800 50,700 57,400 64,200 71,800 78,700 85,500 92,400 900 54,600 61,900 69,200 77,600 85,000 92,300 99,700 1000 58,200 66,000 73,700 82,800 90,700 98,600 106,500 1100 61,500 69,700 78,000 87,600 96,000 104,300 112,700 1200 64,600 73,200 81,800 92,100 100,900 109,700 118,500 1300 67,400 76,400 85,400 96,300 105,500 114,600 123,800 CBWMV-36C-090 HEATING OUTPUTS NOTE-Capacities in shaded area require Harmony IIITM Zoning System to reach the air volumes listed Air Heating Outputs At Various Water Temperatures (Btuh) Volume(cfm) 140°F 150°F 160°F 170°F 180°F 190°F 200°F 400 31,400 35,600 39,800 44,100 48,400 52,600 56,800 500 38,000 43,000 48,100 53,400 58,500 63,600 68,700 600 44,000 49,900 55,800 62,000 67,900 73,800 79,700 700 49,600 56,200 62,900 69,900 76,600 83,300 90,000 800 54,800 62,100 69,400 77,300 84,700 92,100 99,400 900 59,600 67,500 75,500 84,200 92,200 100,200 108,300 1000 64,100 72,600 81,200 90,600 99,300 107,900 116,500 1100 68,300 77,400 86,500 96,700 105,900 115,100 124,300 1200 72,200 81,800 91,400 102,300 112,000 121,800 131,500 1300 75,900 86,000 96,100 107,600 117,900 128,100 138,400 CORRECTION FACTOR FOR DIFFERENT INLET AIR TEMPERATURES 60°F Add 6% RECEIVED 65°F No Change 70°F Minus 6% 04/06/2018 75°F Minus 12% ASPEN CBWMV /Page 10 BUILDING DEPARTMENT HEATING PERFORMANCE CBWMV-60C-100 HEATING OUTPUTS NOTE-Capacities in shaded area require Harmony IIITM Zoning System to reach the air volumes listed Air Heating Outputs At Various Water Temperatures(Btuh) Volume(cfm) 140°F 150°F 160°F 170°F 180°F 190°F 200°F 700 49,600 56,200 62,900 69,900 76,600 83,300 90,000 800 54,800 62,100 69,400 77,300 84,700 92,100 99,400 900 59,600 67,500 75,500 84,200 92,200 100,200 108,300 1000 64,100 72,600 81,200 90,600 99,300 107,900 116,500 1100 68,300 77,400 86,500 96,700 105,900 115,100 124,300 1200 72,200 81,800 91,400 102,300 112,000 121,800 131,500 1300 75,900 86,000 1 96,100 107,600 117,900 128,100 138,400 1400 79,300 89,900 100,500 112,600 123,400 134,100 144,800 1500 82,600 93,600 104,600 117,400 128,600 139,800 150,900 1550 84,200 95,400 106,600 119,700 131,100 142,500 153,900 1700 88,600 100,400 112,300 126,200 138,200 150,200 162,200 1900 94,000 106,600 119,100 134,100 146,900 159,600 172,400 2100 99,000 112,200 125,400 141,300 154,800 168,200 181,700 CBWMV-60C-120 HEATING OUTPUTS NOTE-Capacities in shaded area require Harmony III TM Zoning System to reach the air volumes listed Air Heating Outputs At Various Water Temperatures(Btuh) Volume(cfm) 140°F 150°F 160°F 170°F 180°F 190°F 200°F 700 55,000 62,400 69,700 77,400 84,800 92,200 99,600 800 61,600 69,800 78,000 86,700 95,000 103,200 111,500 900 67,700 76,700 85,800 95,500 104,600 113,700 122,700 1000 73,500 83,300 93,100 103,800 113,700 123,500 133,400 1100 79,000 89,500 100,100 111,600 122,300 132,900 143,500 1200 84,100 95,400 106,600 119,100 130,400 141,700 153,100 1300 89,000 100,900 112,800 126,100 138,100 150,100 162,100 1400 93,600 106,100 118,600 132,800 145,400 158,100 170,700 1500 98,000 111,100 124,200 139,100 152,400 165,600 178,900 1550 100,100 113,500 126,800 142,200 155,700 169,300 182,800 1700 106,100 120,200 134,400 150,900 165,300 179,700 194,000 1900 113,400 128,500 143,600 161,600 177,000 192,400 207,800 2100 120,000 136,000 152,000 171,300 187,600 203,900 220,300 CORRECTION FACTOR FOR DIFFERENT INLET AIR TEMPERATURES 60°F Add 6% 65°F No Change 70°F Minus 6% 75°F Minus 12% RECEIVED 04/06/2018 ASPEN BUe ''bE f1v1ENT REVISIONS Sections Description of Change Optional Accessories Revised Optional Circulating Pump capacity. c Ous Visit us at www.lennox.com JENNOX For the latest technical information,www.lennoxdavenet.com Contact us at 1-800-4-LENNOX RECEIVED NOTE-Due to Lennox'ongoing commitment to quality,Specifications,Ratings and Dimensions subject to change without notice and without incurring liabiliO 4/0 6/2 01 8 Improper installation,adjustment,alteration,service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2014 Lennox Industries,Inc. ASPEN BUILDING DEPARTMENT STAINLESS STEEL INDIRECT WATER HEATERS Staideaa see %dozect 2Uatez ' P 12 SQUIRE MODELS TO CHOOSE FROM - 6 STANDARD MODELS FROM 30 TO 119 GALLONS - 6 SOLAR MODELS FROM 65 TO 119 GALLONS 316L PASSIVATED STAINLESS STEEL TANK 316L HIGH CAPACITY STAINLESS STEEL COIL FULLY WELDED CONSTRUCTION DESIGNED*ENGINEERED*ASSEMBLED Ok--140C111-4M* ar HIGH EFFICIENCY BOILERS&WATER HEATERS Lochs va 'EN BUILDING I 'ARTMENT Sauire. Stain Seed 1ed'vzect Vaterz geate't - a new Class of Water Heater The Squire Stainless Steel Indirect Water Heater--with 12 models to choose from in capacities from 30-119 gallons, we are sure to have the right size indirect water heater to fit your application. Squire features important enhancements that our customers will recognize and benefit from such as a welded and passivated stainless steel tank and heat I exchanger, two-inch thick, high-density insulating foam, and best of all it is designed, engineered and assembled in America. Stainless Steel Tank Manufacturing Laser Cut Precision A CNC laser uses Programmable Logic Controls to precisely cut the Squire Indirect Water r Heater's tank shell out of 14 gauge 316L stainless steel to a tolerance of.01 inch. ',',„_,,i t,', , Tank Cylinder Roller . _=- The computer controlled tank cylinder rolling machine ensures that the 316L stainless _ L' > steel is transformed into a geometrically perfect cylinder. Coil Winder Straight tubes are rolled by a seven axis coil winder and turned into a precise,round LASER Cut Precision coil used in the indirect water heater to transfer the BTU's from the heat source to the potable water stored in the tank. Robotic Welder ��„ This state of the art six axis programmable robotic welder uses computer guidance to 1) ��, `�'c ,r accurately weld the stainless steel fittings to the tank. • ,. . ;. .. J Hydrostatic Leak Test n - After welding,the tank is hydrostatically pressure tested to ensure quality i / - - conformance. ; Passivation Process PFIIIIIIIIII"Plr Each tank is subjected to a soaking spray of �'t r ! nitric acid.This treatment washes away any' -5111ML. tibi iron that was left behind during the welding -- process and re-establishes the oxide level of the stainless steel to ensure corrosion resistance. Robotic Welder By removing iron from the welded surfaces,the y 11 -1 Squire is less susceptible to corrosion brought %%\ _^ ^ ! u on by aggressive water. $ - 1 i : . Jacket and Foam I r I ni --- ` :li i The dent resistant polypropylene jacket and ; M P ` _ f ;,P. i j;toa. •� ABS caps are attached to the tank assembly, �..1,2 - , ;: and then high density foam is added using a - : stit ' J. high pressure dispensing system to provide 1 diggialkc insulation that will keep the heat where it ,� 0 belongs, in the water.The result is a tank that 1llill1[ is jacketed and evenly foam insulated with Passivated for Protection standby losses as low as 0.5°F per hour. Foam Insulation fifes@ 6/2 I 8 2 -I ASPEN BUILDING DEPARTMENT Outstanding Features - Six Standard Models from 30 to 119 Gallons 316L Passivated Stainless Steel Tank The highest quality indirect water heater in the market also has 316L Stainless Steel material is used for the tank interior for one of the widest ranges of gallon capacities. With 6 models superior durability and long life. The rust prohibitive characteristics covering gallon capacities from 30 to 119 gallons the Squire is of this material make it the perfect material to resist the corrosive one of the broadest lines available. tendencies of domestic water. The passivation process consists of a treatment method that enhances and increases the superior Six Solar Models from 65 to 119 Gallons corrosion resistance of stainless steel. With three dual coil models for solar heating in conjunction with a heat source and three models with a solar coil and an electric 316E High Capacity Stainless Steel Coil element the Squire line of water heaters has a model to fit any The Squire's 316L Stainless Steel heating coil efficiently transfers high residential or light duty commercial solar application. volumes of BTU's from the heat source to the domestic water with high first hour delivery capability. 100%Stainless Steel Construction Squire Water Heaters are constructed with Stainless Steel Designed, Engineered and Assembled in the USA materials that are highly resistant to corrosion that can result A 100%stainless steel indirect water heater built in the USA, from poor water quality. the Squire is completely assembled in Lebanon, Tennessee. Inside Look How it Works Dent resistant polypropelene jacket* Temperature Stainless Steel SIT Indirect \frill:WA- &pressure The Squire uses the power and efficiency of the relief valve building's heating boiler or solar array to generate domestic hot water for showers, dishwashing, clothes Boiler Sensor washing or any potable hot water demand. The water inlet well efficiency of the heating boiler could be as much as 20% • higher than a direct-fired tank-type water heater. So,why '"' 316E not use that efficiency to "indirectly" provide hot water for Stainless all potable applications? Steel coil By using the Squire to indirectly heat the domestic water,you Boiler water eliminate the additional gas line,electrical connections and vent ducts needed with direct-fired tank-type water heaters. outlet — High density foam insulation Cold water / inlet --------iiiam0 *SET models feature metal jacket 9g 1 s wows.. - {: •� � — ; 4 f - i` 1 . .: ;,, . _1::, -,. _. -., ,..,7: , .....,...11,.../. ...Mr- , 41 111 011 ' \ y � .R ii ., 'IK 111W Combine the Knight Heating Boiler with ther 411, ED Squire Indirect for the perfect combination for your application. 0 4/0 6/2 018 3 Ilir lir ASPEIIM BUILDING DEPARTMENT Fully Welded Construction T&P Relief Valve Lochinvar utilizes state of the art, highly accurate robotic Supplied with the unit in the carton. (shipped loose) welding equipment that results in a fully welded construction method that requires no gaskets or mechanical sealing High Density CFC/HCFC Free Polyurethane Foam methods. Gaskets and seals are the weak point of any water Two inches of R-13.4 High Density Polyurethane foam yields storing appliance, therefore Lochinvar's advanced design the lowest standby losses in the industry. eliminates this potential failure point. Attractive Rust Resistant Jacket Factory Supplied Tank Sensor (SIT and SDT only) Resistant to scratches and dents, the Squire will maintain its A tank sensor with built in temperature limit is standard classic high quality appearance for years. equipment on all sizes. This sensor accurately monitors the water temperature and sends a call for heat when the tank Limited Lifetime Warranty* temperature drops below the desired setpoint. This sensor Lochinvar believes that the Squire is the best built Indirect is 100%compatible and can be directly connected with Water Heater on the market, we have a Limited Lifetime Lochinvar's line of KNIGHT or Cadet Heating Boilers. warranty to prove it. *SIT models only Solar Indirect with SDT Dual Coil Solar Indirect with SET Electric Back-up Squire Indirect Water Heaters with a dual coil design Squire Indirect Water Heaters with a single coil and have a coil in the lower portion of the tank to transfer an electric element are designed to collect heat from heat from a solar array to the water that is stored in a solar array and transfer the collected heat into the tank. the stored water by way of the indirect coil which is located in the lower portion of the tank. An additional coil in the upper portion of the tank will transfer heat from a back-up boiler into the An electric element,which is controlled by a factory water. This will ensure that the tank has ample hot supplied thermostat, is positioned in the top half of water even at times when the solar array cannot the tank to ensure ample hot water even at times generate enough heat to suitably heat the tank. when the solar array is not capable of collecting the heat required by the DHW demand. ____, 4 __ Ell[7- 111/ ,,. il- 1 T ® 0 ,A. , , to. I 415 , p iii, • fVED 04/011,2018 Miw - ASPEN BUILDING DEPARTMENT Stainless Steel Indirect SIT Models Dimensions and Specifications HOT WATER "''� OUTLET EID RELIEF VALVE (shipped loose) - A BOILER z25=\ N IN al s 45° D \ SENSOR WELL G BOILER n'/OUT The"Hot Water Outlet"connection is Female NPT. H I 0 All other connections are Male NPT.ii COLD WATER INLET Domestic Coil Model Water Connection Shipping Number A B D G H I Conn. Size Wt. (lbs.) SIT030 39-1/2" 20" 32-1/4" 21-3/4" 8-1/4" 3" 1" 1" 79 SIT040 55-3/4" 20" 48-1/2" 25-1/4" 8-1/4" 3" 1" 1" 105 SIT050 48" 24" 39-3/4" 24-1/2" 9-1/4" 3-3/4" 1" 1" 131 SIT065 60" 24" 52-1/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 147 _ SIT080 69-1/2" 24" 61-3/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 177 SIT119 69" 28" 60-1/4" 31-3/4" 9-1/4" 3-1/4" 1-1/2" 1" 213 Heat Source Standby First Continuous 1st Hour Min. Flow Friction Model Capacity Water Volume Loss Draw Delivery Delivery Coil Load Rate Loss Number (Gallons) (Gallons) (°F/Hr) Gals. (GPH) (Gallons) (Btu/Hr) (GPM) (Ft. Hd.) SIT030 27 1.1 1.5 24 160 184 99,000 14.0 3.9 SIT040 40 1.6 0.9 27 181 208 115,000 14.0 4.5 SIT050 52 1.7 0.9 45 210 255 133,000 14.0 5.3 SIT065 67 1.9 0.7 65 263 328 154,000 14.0 5.7 SIT080 82 2.1 0.6 74 266 340 160,000 14.0 5.7 SIT119 113 3.2 0.5 109 308 418 199,999 14.0 6.5 Performance data is based on IWH-TSI test results.All ratings are based on 180°F boiler water temperature with incoming cold water at 58°F and a Delta T of 77°F. Includes tank sensor for use with KNIGHT or Cadet Heating Boiler. Optional thermostat available for use with other boiler models. SIT MODELS All models standard with a Lifetime Limited Warranty Against Tank Failure. All parts are warranted for one year. Five year limited tank warranty on all $U11211a models when installed in a commercial ram■■ai CERTIFIED,. S)' www.hnao-.mow.or° application. C US L01NLEAD pp �QNTFN� 04/06/201 ASPEN BUILDING DEPARTM Solar Stainless Steel Indirect Dimensions and Specifications B HOT WATER FROM HOT WATER OUTLETILER OUTLET BOILER 'Iw = O RELIEF VALVE SENSOR (sM1ippea looseI WELL RELIEF VALVE R TO (.M1ivv.a looms) 1* -22.5°45° X 1 BOILER / 22.5° 45° A FROM A PANEL DFROM r PANNEL D ® E SOLAR SOLAR SDT Models F SENSOR SET Models WELL G G TO PANEL 1 /PANEL t I t t H 1 �- f COLD WATER COLD WATER INLET INLET The"Hot Water Outlet"connection is Female NPT. SDT Models Dimensions and Specifications All other connections are Male NPT. Domestic Coil Model Water Connection Shipping Number A B D E F G H I Conn. Size Wt.(lbs.) SDT065 60" 24" 52-1/4" 47-1/4" 33-3/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 158 SDT080 69-1/4" 24" 61-3/4" 53-3/4" 40-1/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 188 SDT119 68" 28" 60-1/4" 54-1/2" 37-1/2" 31-3/4" 9-1/4" 3-1/4" 1-1/2" 1" 224 Heat Boiler Heat Standby Continuous 1st Hour Min. Flow Friction Model Capacity Source Water Source Water Loss Delivery Delivery Coil Load Rate Loss Number (Gallons) (Gallons) (Gallons) (°F/Hr) (GPH) (Gallons) (Btu/Hr) (GPM) (Ft. Hd.) SDT065 66 2.1 1.7 0.7 175 205 128,000 14.0 3.4 SDT080 79 2.1 1.7 0.6 175 208 128,000 14.0 3.4 SDT119 110 3.2 2.6 0.5 251 301 181,000 14.0 4.9 Performance data based on incoming cold water at 50°F and a Delta T of 77°E Delivery ratings for boiler coil only.Includes tank sensor for use w/KNIGHT Heating Boiler. SET Models Dimensions and Specifications Domestic Coil Model Water Connection Shipping Number A B D G H I Conn. Size Wt. (lbs.) SET065 60" 24" 52-1/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 149 SET080 69-1/2" 24" 61-3/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 179 SET119 68-1/4" 28" 60-1/4" 31-3/4" 9-1/4" 3-1/4" 1-1/2" 1" 215 Electric Electric Heat Source Standby Continuous 1st Hour SET&SDT MODELS Model Capacity Water Loss Delivery Delivery All models standard with a 5 year Number (Gallons) (Gallons) (°F/Hr) (GPH) (Gallons) Limited Warranty Against Tank Failure. All parts are warranted for one year. SET065 67 1.9 0.7 24 54 SET080 81 2.1 0.6 24 57 SET119 113 3.2 0.5 24 75 All SET models:4500w 240v 1 phase. RECEI AVd * War c, Lochinvar,LLC aC41) us �\�� � Loc Maddox Simpson Parkway Op��lilii Lebanon Tennessee 37090 0`! 0 6 P:615.889.8900/F:615.547.1000 / / HIGH EFFICIENCY BOILERS&WATER HEATERS C us *SET models onlyLOW LEAD El©®0 Lochinvar.com CONTENT SIT-02(Reprint SIT-02 10/15) (Website Update 9/16 PDP-10M-5/16—Print d in U.S 5. Bighorn Consulting Engineers,Inc. ROOF DEW POINT ANALYSIS Outside air film—0.17 °F*ft2*h/Btu Roofing Material—0.33 °F*ft2*h/Btu 5/8"plywood—0.77 °F*ft2*h/Btu Joists roof framing with spray foam insulation— 8" at R5.8/inch=>46.4 °F*ft2*h/Btu 5/8"gypsum board—0.56 °F*ft2*h/Btu Inside air film—0.61 °F*ft2*h/Btu Total Roof R-Value—49 °F*ft2*h/Btu Interior Conditions—70°F and 35% RH=>Dew Point= 41°F R-Value at 41°F Dew Point: ° f a 49 F • t • h 99°F L T x (70°F DB — 41°F DP) = 14.35 Btu This implies the dew point falls inside the spray foam insulation. R 210 S. First St.Residence Aspen,Colorado-Roof Dew Point Analysis-17146 6i0 b 6/2 018 ASPEN BUILDING DEPARTMENT 0_ 'c FV-05-11VK1 W.,- h P r G ree nselCeet Adjustable Airflow for Maximum Performance VENTILATION'.FAN Specification Submittal Data /Panasonic Ventilation Fan Description Customizable Ventilation Fan shall be low sone ceiling mount rated for continuous 411 or 61' duct run. Fan shall be ENERGY STAR®rated and certified by the Home Ventilating Institute (HVI).Evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards. Motor/Blower: •Enclosed DC brushless motor technology rated for continuous run. •Fan ventilation rates shall be manually adjustable for 50-80-110 CFM. 0vo '_ •Power rating shall be 120 volts and 60 Hz. •Fan shall be UL listed for tub/shower enclosure when used with a GFCI protected \ � ' circuit and used in insulated ceiling(TYPE IC.). 4�' ` •Fan equipped with a thermal cutoff fuse �- Ili--III .�`` ; _ •Removable,permanently lubricated,plug-in motor. -__- % / • '4 Housing: •Rust proof epoxy and polyester resin coating,26 gauge galvanized steel body. ,✓z •Integrated dual 4"or 6"diameter duct adapter. ' •Built-in metal flange provides blocking for penetrations through drywall as an Air - 7 Barrier,and assists with the decrease in leakage in the Building Envelope during ., 1411141000. blower door testing. •Built in backdraft damper. •Articulating and expandable installation bracket up to 24". Grille: \ �� •Attractive design using Poly Pro material. •Attaches directly to housing with torsion springs. •Includes a motion sensor cap for use as a cover when motion sensor Plug'n PlayTM module has not been selected. Warranty: •ALL Parts:3 Years from original purchase date. DC Motor:6 Years from original purchase date. Architectural Specifications: FV-05-11 VK1 Customizable Ventilation Fan shall be ceiling mount, ENERGY STAR®rated type with built-in speed selector. Select from 50/80/110 CFM and no more than<0.3 sone as certified by the Home Ventilating Institute(HVI)at 0.1 w.g.with no less than 53/82/113 CFM and no more than<0.3/0.4/0.8 sones at.25 w.g.Power Consumption shall be no Performance Curve 4"or 6"duct greater than 3.2/5.4/9.8 watts at 0.1 w.g.and 6.5/10.2/16.1 watts at 0.25 w.g.ENERGY 0.80 STAR®rated with efficiency of no less than 15.1/15.3/11.5 CFM/watt at 0.1 w.g.and than 8.1/8.4/7.2 CFM/watt at 0.25 w.g. The motor shall be enclosed with brushless , 070 DC motor engineered to run continuously.DC motor speed shall automatically increase _ „ ,. .. when the fan senses static pressure to maintain selected CFM. Power rating shall be a oso =� „ ,00CF 120v/60Hz. Duct diameter shall be no less than 4", inclusive of an integrated dual 4" o50 ,_ — or 6"duct adapter. Plug 'N PIayTM modules provide up to three additional features. _.,,-,_ —,OCFM Select from Multi-Speed with Time Delay, Condensation Sensor, LED Night Light and 040 -,,.,,-,\ —eOCFM Motion Sensor. Fan shall be UL and cUL listed for tub/shower enclosure when used pl 50CFM with a GFCI protected circuit. Fan can be used to comply with ASHRAE 62.2, LEED, o so ��,��.,�� —oCFM ENERGY STAR®IAP,EarthCraft,California Title-24 and WA Ventilation Code. 0.20 ,��,,.��� DC Motor Technology: ow When fan senses static pressure,its speed is automatically increased to -- co. Fi0�. ensure that the desired CFM is not compromised,which allows the fan o00 T 0 20 40 60 80 100 120 DC to perform as rated. A «,°HNov°� Model Quantity Comments Project: Location: Architect: Engineer: RECEIVED Contractor: Submitted by:Date: p 4/0 6/2 018 For complete Installation Instructions visit us.panasonic.com/ventfans ASPEN BUILDING DEPARTMENT Qp$ASO41 Who c__D rG ree�eCect aximu b Airflow for FV-05-11 VK1 5 5V` Maximum Performance VENTILATION FAN Plug 'N PlayTM Modules Plug 'N Play-modules provide up to three additional features.Select from Multi-Speed with Time Delay, Motion Sensor,Condensation Sensor and LED Night Light. FV-VS15VK1: Multi-Speed with Time Delay 1111 Allows you to select the proper CFM settings to satisfy ASHRAE 62.2 continuous ventilation requirements. The fan runs continuously at a pre-set lower level(0,30-100 CFM,in 10 CFM increments),then elevates to a maximum level of operation (50-80-110 CFM)when the wall switch is turned on,or when the motion sensor or Condensation Sensor module is activated. A High/Low delay timer returns the fan to the pre-set CFM level after a period of time set by the user. FV-MSVK1: Motion Sensor ®• Automatically activates when someone enters the room.Once the settings have been applied,the fan becomes truly automatic. This module also activates a 20 minute delay off timer for the fan. FV-CSVK1: Condensation Sensor Helps control bathroom condensation to prevent mold and mildew.Sensor technology detects relative humidity and temperature a to anticipate dew point,automatically turning the fan onto control humidity.Built-in Relative Humidity(RH)sensitivity adjustment enables fine tuning for moist conditions and for satisfying CalGreen requirements.When the condensation sensor is used in • conjunction with multi-speed functionality,the fan will kick up to high speed when the condensation sensor detects moisture in the room.This module also activates a 20 minute delay off timer for the fan. FV-NLVKI: LED Night Light A photocell automatically turns on the 1 watt LED night light when darkness is sensed in the room. High/Low brightness switch enables you to fine tune the photocell to work in conjunction with the darkness level of your bathroom.This module / also activates an automatic 20 minute delay off timer for the fan. Fan Specifications WhisperGreen Select"FV-05-11 VK1 Static Pressure in inches w.g. 0.1 0.25 0.1 0.25 0.1 0.25 Air Volume(CFM) 110 113 80 82 50 53 Noise(sones) <0.3 0.8 <0.3 0.4 <0.3 <0.3 Power Consumption(watts) 9.8 16.1 5.4 _ 10.2 3.2 6.5 Energy Efficiency(CFM/Watt) 11.5 7.2 15.3 8.4 15.1 8.1 Speed(RPM) 931 1205 814 1131 747 1072 Current(amps) 0.10 0.16 0.06 0.10 0.04 0.07 MAX.Current(amps) C.27 Power Rating(V/Hz) 120/60 ENERGY STAR rated Yes 0.25=Installed Performance Fan Specifications WhisperGreen Select":FV-05-11VK1 +FV-VS15VK1 (Multi Speed Plug'N Play-Module) Static Pressure in inches w.g. 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 Air Volume(CFM) 110 113 100 106 90 95 80 82 70 71 60 66 50 53 40 43 30 33 Noise(sones) <0.3 0.8 <0.3 0.7 <0.3 0.6 <0.3 0.4 <0.3 0.4 <0.3 0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 Power Consumption(watts) 9.8 16.1 8.0 14.0 6.5 11.7 5.5 10.2 4.3 8.6 3.6 7.8 3.2 6.5 2.7 5.7 2.4 5.0 Energy Efficiency(CFM/Watt) 11.5 7.2 13.0 7.9 14.5 8.5 15.3 8.4 17.2 8.7 17.5 8.8 15.1 8.1 16.3 8.2 14.2 7.6 Speed(RPM) _ 931 1205 895 1179 852 1146 814 1131 772 _1112 750 1107 747 1072 731 1073 718 1062 Current(amps) 0.10 0.16 0.09 0.14 0.07 0.12 0.06 0.10 0.05 0.09 0.04 0.08 0.04 0.07 0.08 0.06 0.03 0.06 MAX.Current(amps) 0.27 Power Rating(V/Hz) 120/60 ENERGY STAR rated Yes 0.25=Installed Performance Panasonic Eco Solutions Company of North America r,Most Efficient Eco Products Division Two Riverfront Plaza Newark,NJ 07102 El-al-S E CO us.panasonic.com/ventfans ENEPGVSIAP Panay l 8 ASPEN VF16006SS0116 BUILDING DEPARTMENT Water Circulation series Pumps & Circulators OOe® Series VR ECM High-Efficiency Circulators The 00e'series—These are browser accessable,high-efficiency,wet rotor,variable speed, sensorless commercial pumps for chilled and hot water applications. Available in four sizes (VR 15-3,20-3,25-3 and 30-3),the sensorless 00e VR line provides differential head pressures up to 42 ft.and flows up to 360 GPM. The ECM motor provides up to 85%electrical energy savings compared with conventional pumps and its multiple operating modes fit most applications. • Simple user interface to enable setting changes on the face of the pump,eliminating the need for laptop setup • Real-time performance readouts for flow, power consumption, speed and head values 00 I` • Self Sensing Dynamic Auto _ (factory default),Proportional &Constant Pressure plus Manual , Variable Speed modes provide for extremely extensive application flexibility • On board 0-10Vdc two way control adjusts speed or head to meet system demands from external control inputs Cum ti • ModBus control and performance feedback for advanced Building Management/Building ITOus Automation Systems 4004896 p p • RJ 45 input/output for ease of networking Web connections are a snap. • Relay outputs for remote monitoring of pump status and digital inputs for external enable/disabling • Simple Main/Standby and Parallel Pump operation (parallel pumps run together as needed)via standard ethernet cabling Wdico Comfort/Soiutions® A Taco Family Company ©Taco Catalog#300-23 EffR � IvE n Supersedes:06/23/17 ranted in USA 04 06 2018 ASPEN BUILDING DEPARTMENT A convergence of efficiency, simplicity & technology. Efficiency as the basis of design precisely drive the rotor as fast as Flexibility to fit the job The ECM based design combines a the rotating flux,significantly reduc- The hydraulic characteristics of the brushless Electronically Commutat- ing motor efficiency losses while pump can be set at will. Pump ed Motor with a strong permanent greatly increasing starting torque. regulation can be done by pressure, magnet rotor. An ECM motor does speed,electrical power or a combi- not waste any energy in order to Full variable speed control nation of these,so it can be adapted magnetize the rotor and the posi- matches system requirements to different hydraulic system tion of the magnetic poles of the The electronics continually adapt requirements without the need rotor and stator generate continu- the speed to match the require for external regulators or sensors. ous thrust in the rotating direction ments of the system. Because the of the rotor. The integral electronics electrical motor is being driven by Ready-to-go out of the box,this an on-board frequency converter pump will automatically adjust its cnoosscmutot,00 the electric current is rectified and speed based on internally sensed converted into the appropriate variable differential pressure control, phase angle to maximize energy providing optimal energy savings 1 efficiency,even when operating at across the industry's largest oper- hydraulic partial load conditions. ating range. Additional modes of The superior motor efficiency,opti- control can be selected to provide mized speed control,and intelligent constant pressure control, propor- sensorless variable speed pump tional pressure control,constant The position of the magnetic poles of the rotor control delivers dramatic cost sav- maintains ultimate motor EFF over the speed curve duty(uncontrolled pump), and load range of the unit. ings over the life of the system. multiple speed,RPM regulation or Up to 85%Electrical Savings power limitation control. Connecting with Ethernent These pumps can be operated as crossover cable single, parallel or series variable - ___ Boa,.-„ „ speed pumps. The onboard elec- tronics allows the user to choose to run two pumps in parallel,standby . , or alternating modes. The built-in normally open,or normally closed 00 relay contacts can be used to — activate or deactivate a primary or 0,0 The Cloud . secondary pump contact, provide . • external operation or overload ibli Connecting � - feedback or switch another piece of - with LAN equipment. In addition,this pump rz,., comes standard with 2 external digital inputs and 1 external digital .-- S output to be available for additional mechanical room control and pump monitoring. RECEIVE! 04/06/2018 ASPEN 'BUILDING DEPARTMENT Taco; the new generation of wet rotor pumps. Heating,air conditioning or chilled water systems These pumps are built to exacting .. .o,.-�.m. m,�. M . . specifications meeting the widest -_--•-- range of closed loop hydronic "' """ ....°•.. heating and cooling applications. ‘11111 • �e ___, They are suitable for use with fluids �" at temperatures from 14°-230°F ' _-a A4;. � .a . (-10°- 110°C),feature 175psi working — —._ pressure and have a stainless steel • impeller and shaft.Continuous E"�rglvI� /NE duty rated with a built-in soft p Q start-up circuit the VR15-3&VR20-3 6 can accept 110-240 volt and the VR25-3 and VR30-3 operate on 230-240 volt supply power. MEM Lower installation,commissioning and total cost of ownership Orieer.les OM=, OCRes A simple ethernet connection on the pump gives instant remote control, a`; • , , �� r�°� monitoring and adjustment without Taca -Mc( -Waco requiring highly skilled network Proportional Pressure Constant Pressure Fixed Speed IT or commissioning personnel. Web-based simplicity The environment is Adjustments for Proportional Simply launch any common browser always a consideration Pressure,Constant Pressure and (Internet Explorer®or Firefox®)type in Not only do these pumps use 85% Fixed Speed can now be made "OOe"or the pump's IP address in the less energy(Meeting EUlegislation directly on the pump. browser's address line and you have with A"class energy rating)than instant,automatic and full control a standard commercial pump but The in-line design and standard over the pump(s). we also made the choice to use ANSI class 125 flanges make for a components, processes and technician friendly installation. The The HTTP or FTP protocol ensures manufacturing capabilities which pump and motor form an integral a user-friendly,commonly used keep the environment in mind. unit without a mechanical seal. environment. The bearings are lubricated by the Performance Range pumped fluid,ensuring years of 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 50 quiet,maintenance free operation. as 0 VR15-3 14 To protect your investment in the ° ���✓ ries ©VR25-312pump it provides dry run,overcurrent, 35ECM HIGH-EFFICIENCY CIRCos- p vR3o-3 ,0 line surge and current limit protec tion,thermal monitoring,heat sink a 25IlL1\13‘, e status and over temperature protec- = 20 6 tion. Given all the advantages stated 15 -441411111 above,the total cost of ownership of ,o a the pump is by far the lowest for its 5 2 performance range. ° •.0� �� a zs 50 15 100 125 150 175 200 zzs 250 275 300 325 350 375 Er) FLOW(GPM) =Pr 04/06/2018 ASPEN ! UILDING DEPARTMENT Submittal Data Information Submittal Data#301-3000 Effective:08/08/17 Supersedes:05/09/17 00e° series —VR15-3, 20-3, 25-3 & 30-3 Pump Specifications Electrical Specifications Max.Operating Pressure: 1 phase,110-240V,47-63Hz(VR15&VR20) 175 PSI(12 bar) Pump Ratings 1 phase,230-240V,47-63Hz(VR25&VR30) Water Temperature Range: 36°-230°F(2.2°-110°C) VR15-3=0.027-0.68 HP Ambient Operation Temperature Range: VR20-3=0.035-1.088 HP 32°-104°F(0°-40°C) Power Consumption(HP) VR25-3=0.054-1.496 HP Designed for closed loop heating and VR30-3=0.054-2.175 HP cooling systems pumping water or a water/glycol mixture VR15-3=20-500 W Power Consumption(W) VR20-3=26-800 W Materials of Construction VR25-3=46-1100 W Casing Cast Iron VR30-3=40-1550 W Impeller Stainless Steel VR15-3=5.6A-2.8A Shaft Stainless Steel Bearing Metal Impregnated Carbon Rated Current VR20-3=7.2A-3.6A (1 phase,230V) VR25-3=5.3A Standards&Protection VR30 3=7.2A Insulation:Class H VR15-3&VR20-3=6 A Current Limit(Max.) Enclosure:Class 2,IP44 VR25-3&VR30-3=8 A Integrated Motor Protection Max.Current upto 100 mA,OutputVolta e (electronically protected) 24V Supply Output of 24V 20%, ut Output Ripple uner 1 V g Continuous Duty p pp UL 778,1004-1,508C CAN/CSA C22.2#108,#100,#107.1 Relay Output: 8A,Max.Voltage 250 VAC,48 VDC EMC(89/366 EEC):EN 61000 Max.Load up to 500 VA LVD(73/23/EC):EN 60335-1,EN 60335-2-51 Max.Input Voltage=32VDC Machine Safety(98/37/EC):EN ISO 12100 Digital Inputs: 2 Inputs&1 Output Operating Modes Logical»1«Voltage>8V,Logical»0«Voltage<2V Constant Pressure Control(Ap-c) Connector=RJ-45 Variable Differential Pressure Control Ethernet: (Ap-v)-factory default Services=http server and client,FTP server Proportional Pressure Control —o-••• B Minimum static inlet pressure at Constant Curve Duty(uncontrolled pump) pump suction port(PSI/bar)to avoid 1 I_ cavitation at fluid temperatures RPM Regulation ^'�= ��61 I Fluid VR15&VR20 VR25&VR30 Power Limitation(amps or watts) Temperatures (PSI/bar) (PSI/bar) :6-41® �, J 112°F(50°C) 7.3/0.5 4.35/0.3 Control Modes r: j� ki 176°F(80°C) 11.6/0.8 14.5/1.0 0 10Vdc in D --7- 1 230°F(110°C) 20.3/1.4 23.2/1.6 ModBus RTU Model Flange Size Power A B C D E F Weight Number (ANSI) (HP) in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg VR15-3 1-1/2" 0.027-0.680 9-13/16 250 15-3/16 386 12-5/8 321 7-13/16 198 7-7/16 189 10-1/16 255 57 26 VR20-3 2" 0.035-1.088 11 280 16-3/4 425 13-1/4 336 7-15/16 201 7-7/16 189 10-1/16 255 71 32 VR25-3 2-1/2" 0.054-1.496 13-3/8 340 17-11/16 449 14-1/2 369 8-11/16 221 7-7/16 189 10-1/16 255 82 37 VR30-3 3" 0.054-2.175 14-3/16 360 19-13/16 503 15-7/8 403 9-1/4 235 7-7/16 189 10-1/16 255 99 45 1 I,c us 4004896 Wg4"Cil FOR INDOOR USE ONLY CCOmfO/tiKSO/Ut/OnS® A Taco Family Company Taco Inc., 1160 Cranston Street,Cranston,RI 02920/(401)942-8000/Fax(401)942-2360 RECEIVEn Taco(Canada)Ltd.,8450 Lawson Road,Unit#3,Milton,Ontario L9T 0J8/(905)564-9422/Fax(905)564-9436 www.TacoComfort.com f y in 0 4 0 6 2 018 ASPEN BUILDING DEPARTMENT 302-385 1DãCO Installation and Operation Instructions Comfort.Solution A Taco Family Company VR15-3, VR20-3, VR25-3, VR30-3 SUPERSEDES:NEW EFFECTIVE:JUNE 23,2017 Plant ID No.001-3452 • Oir — or / 1 k series RECEIVED ECM HIGH-EFFICIENCY CIRCULATOR 04/06/2018 ASPEN BUILDING DEPARTMENT CONTENTS 1. Symbols and conventions used in this 13. Module layout 14 document 3 13.1 Connection considerations. 15 1.1. Abbreviations and conventions 3 13.2 Connection examples 16-17 2. Introduction 3 14. Control modes and priorities 18 Section 1 -Installation and Operation 4 14.1 Priority of settings 18 3. General Uses 4 14.2 Control variables. 18 4. Safety. 4 14.3 Module mode selection. 19 5. Pump Description 5 14.4 Mode 1 20 6. Use 5 Digital (switch)control 20-21 7. Pumped Fluids 5 0-10 VAC control. 22-23 8. Pump Installation 5 14.5 Mode 2 24 8.1. Motor Rotation Procedure 6-7 15. Relay output 24-25 9. Electrical Connections 8 16. Ethernet 26 10. Setup and Operation 8 16.1. Bus topology 26 10.1 Control Panel Layout 8 16.2. Connecting to pump ad-hoc. 26 10.2 Switching the Pump On and Off 8 16.3. Connecting to pump via router 26 10.3 Pump Functions 8 16.4. Pump configuration over Ethernet 26-27 10.4 Operation and Mode Selection 9 17. Modbus 28 10.5 Mode Description 9 17.1 Modbus related interface. 28 10.6 Restoring Factory Settings 10 17.2 Bus topology 28 11. Specifications 10 17.3 Connection to Modbus. 28 11.1 Application 10 17.4 Speed, parity and address. 28 11.2 Electrical Ratings 10 17.5 Termination 28 11.3 Standards, Protection and Flange Conn 11 17.6 Register block overview 29 11.4 Materials of Construction 11 17.7 Configuration register block. 29 17.8 Status register block. 30 Section 2 - Controller Operation 12 17.9 Pump control register block 31 12. Features 12 17.10 Pump status register block. ... 32 12.1 Specifications. 12 17.11 Pump data register block. 33 Modbus 13 18. Faultfinding 34 Ethernet. 13 18.1 Error codes 34 Mode Selection. 13 Analogue Signals 14 Performance Curves 35-36 Relay 14 Limited Warranty Statement 37 WARNING! AInstallation and use of this product requires experience and knowledge of this or similar products. Persons with reduced physical, mental or sensory capabilities must not use this product, unless properly instructed and supervised. Children must not be allowed to play with this product. A WARNING! fi CEI � D Prior to installation and commissioning, read these instructions first. Installation and operation must comp� lywith local regulations. 04/06/2 18 ASFE BUILDING DEPARTMENT 1.SYMBOLS AND CONVENTIONS USED IN THIS DOCUMENT WARNING! Denotes that a failure to observe those instructions might cause damage to equipment or pose danger to the user. 1.1 ABBREVIATIONS AND CONVENTIONS USED IN THIS DOCUMENT Abbreviation Description Baud, Baud rate Serial communication speed, in bits per second including start, parity and stop bits. CRC Cyclic Redundancy Check, additional bytes used to confirm valid data transmission. Ethernet IEEE 802.3, mostly referring to 10BASE-T RJ-45 connector present on board. H Differential pressure, often called Head. LED Light Emitting Diode. Modbus A serial communication protocol used for device automation and remote access. Q Pump flow or flow rate. RTU Remote Terminal Unit. RS-485 Multi drop serial network wiring, used to transfer Modbus data. For Modbus use, this manual assumes that the reader is familiar with commissioning and configuring of Modbus devices. It is also assumed that an existing Modbus RTU network on RS-485 wiring with Modbus master is present. For Ethernet and web interface use,this manual assumes that the reader knows how to configure or already has preconfigured Ethernet network. NOTE: • Data in this document are subject to change. • Actual implementation might differ by pump model and software revision. • Make sure you are using the right manual for your product. • Always verify that the pump is operating as desired after setup is complete. • Manufacturer cannot be held responsible for problems caused either directly or indirectly by the use of information in this manual. 2.INTRODUCTION This manual is broken down into two sections and describes the installation, operation and control module for VR15-3 through VR 30-3 range of pumps. Section 1 describes the installation and operation features. Section 2 describes the control module and its functions. RECEIVED 04/06/2018 3 ASPEN BUILDING DEPARTMENT Section 1 . Installation and Operation 3. GENERAL INFORMATION, USES: The OOe VR 15 - VR30 circulating pumps are used for the transfer of liquid media within a closed-looped hot-water heating or air-conditioning hydronic system. They are designed as single or parallel main/standby operation variable- speed pumps, where the speed is regulated by an on-board electronic device. They are to be used with a water or glycol/water mixture. 4 SAFETY: These instructions should be studied carefully before installing or operating the pump. They are meant to help you with installation, use and maintenance and to increase your safety. Installation should be performed with regards to local or national standards. Only qualified personnel should maintain and service these products. Failure to comply with safety precautions could cause personal injury or machinery damage. A WARNING: Do not use in swimming pool or spa areas. Pump has not been investigated for these applications. AVERTISSEMENT: Ne pas utiliser dans une piscine ou un spa. La pompe n'a pas ete etudiee pour ces applications. WARNING: To avoid electrical shock, disconnect the power supply to the circulator and the main electrical unit. A Follow all local electrical and plumbing codes. AVERTISSEMENT: Pour eviter tout choc electrique,debranchez('alimentation electrique vers le circulateur et('unite electrique principale. Respectez tous les codes de plomberie et electriques locaux. AWARNING: Hot surfaces can cause burns.The motor can also reach temperatures that could cause injury. AVERTISSEMENT: Les surfaces chaudes peuvent provoquer des brulures. Le moteur peut egalement atteindre des temperatures qui peuvent entralner des blessures. CAUTION:The addition of petroleum based fluids or certain chemical additives to systems using TACO equipment Avoids the warranty. ATTENTION: L'ajout de liquides a base de petrole ou de certains additifs chimiques a des systemes utilisant un equipement TACO annule la garantie. CAUTION: Use supply wires suitable for 90°C.ATTENTION: Employer des fils d'alimentation adeqauts pour 90°C. A A CAUTION: Misconnection or overload of electrical or signal connections could cause pump to shutdown or cause permanent damage. ATTENTION: Toute erreur de raccordement ou surcharge des connexions electriques ou de signalisation peut en- trainer un arret de la pompe ou des dommages permanents. A CAUTION: Do not operate pump without the electrical cover securely attached. ATTENTION: Ne pas actionner la pompe si le couvercle electrique n'est pas correctement fixe. CAUTION:Pump motor,electronics enclosure and condensate drain openings should not be thermally insulated as it Acould interfere with cooling and condensate drainage. ATTENTION:Le moteur de pompe,('enceinte electronique et les ouvertures de drainage de condensat doivq ' D miquement isoles car it peut y avoir interference avec('evacuation de condensat et de liquide de refroidi`seehie ' -' 04/06/2018 4 ASPEN BUILDING DEPARTMENT 5. PUMP DESCRIPTION: The high efficiency, electronically commutated 00e VR15- 30 model pumps consist of two main parts,the centrifugal pump and the electronic control.The hydraulic part is hermetically sealed from the motor assembly and has no mechanical seals. 00e pumps are powered by an electronically commutated permanent magnet motor(ECM) which does not consume energy to magnetize the rotor, providing superior energy efficiency. The ECM motor is run by an on-board frequency converter. The converter estimates current flow and head from the motor load, information essential for differential pressure control. 6. USE: All Taco 00e VR pumps are intended for circulation of solid-free fluid in pressurized, hot and chilled hydronic systems. The self-sensing ECM pump constantly calculates pressure and flow, and adapts its speed to the appropriate flow. 7. PUMPED FLUIDS: Use water and water/glycol mixtures only. Water/glycol mixtures must be HVAC-system compatible and should have no more than 50% concentration of glycol. The fluid shall not consist of aggressive or explosive additives and mixtures of mineral oils and solid or fibrous particles. The pump should not be used for pumping flammable, explosive fluids, and in an explosive environment. 8. PUMP INSTALLATION: The 00e(R) pump is protected with a double box during shipping. It can be lifted from the box with internal handles or by lifting it by the heat sink. ACAUTION: Pump may be heavy. Provide yourself help if needed. ATTENTION:La pompe est lourde.Veillez a deman-der de I'aide si necessaire. Pumps are designed to be installed using standard ANSI class 125 flanges. It is recommended that the 00e pumps be installed with at least 5 to 10 pipe diameters of straight pipe on the inlet and outlet of the pump. Use all nuts and bolts to attach companion flanges to the pump flanges. All VR model pumps should be installed with the axis in a horizontal position (see Figure 1). Failure to so may result in excessive noise and vibration. Desired pump orientation can be achieved by rotating the pump casing. The pump is mounted to the volute with four screws. By unscrewing those the head can be turned. See detailed Motor Rotation Procedure 8.1 elovy. Caution: When reassembling, care should be taken to avoid damaging the o-ring and insuring a tight seal RECOMMENDED INSTALLATION POSITIONS Figure 1: 11111111 .‘/11111 411IN _ UNAUTHORIZED INSTALLATION POSITIONS ffi'\ + •MIIIIIIIIIIIII t I t ,�lll I I�I�,IIII` I I111111111111 II _17- •fir ATTENTION!! Installing pumps in UNAUTHORIZED positions may result in voiding the warranty. For replacement 0-rings, use part number 975-001 RP. RECEIVED 04/06/2018 5 ASPEN BUILDING DEPARTMENT FLANGE BOLT SIZES PUMP CLASS 150 ANSI FLANGE Model/Flange Size Bolt Hole Diameter Flange Thickness Bolt Hole Diameter Flange Thickness Minimum Bolt Size Quantity VR15 (1Yz") 0.63 0.715 0.62 0.688 /z"x 2Ya" 4 VR 20(2") 0.75 0.76 0.75 0.75 5/a"x 23/6" 4 VR25 (2/2") 0.75 0.76 0.75 0.875 5/a"x 25/a" 4 VR30(3") 0.75 0.84 0.75 0.938 %"x 2%z" 4 PERMITTED AMBIENT AND MEDIA TEMPERATURE: Ambient Fluid Temperature Ambient Fluid Temperature Temperature [°F] Min. [°F] Max. [°F] Temperature [°C] Min. [°C] Max. [°C] Up to 75 36 230 Up to 25 2 110 85 36 212 30 2 100 95 36 203 35 2 90 105 36 175 40 2 80 ATTENTION!! Operation outside recommended conditions may shorten pump lifetime and void the warranty. 8.1 Motor Rotation Procedure Caution: Motor is heavy! Caution: If system is filled and pressurized, shut off valve before and after the OOe.Allow to cool if system fluid is hot. 8.1.1. Notice! It is recommended to always change the orientation of the motor before installing pump in piping. • Tools Required: • 5/16" or 8mm ball-end hex wrench 11 t • 1/4" or 3/8"flat tip screw driver •g • With motor in a vertical position, remove the 4 bolts (i11.1) • Using a flat tip screw driver, gently pry the motor and housing away from the pump housing ill. 1 • Once loosened, lift the motor off the pump housing, leaving behind the rotor/shaft assembly and seal. (ill. 2) VIII ;.‹ • The motor is now ready to be rotated into the desired position. I." • Before reinstallingthe motor, check to make sure that the rotor/shaft is properly P. iiii r P p Y seated and the seal is properly positioned. (ill. 3) - 'The flange of the rotor/shaft assembly must fit into the shallow groove (ill. 4) —' ' in the pump housing with the 0-ring accessible without removing the rotor/ ill. 2 shaft assembly. 11111,:le • If you determine that the assembly has moved, completely remove the 0-ring and the rotor/shaft assembly. • Reinstall the rotor/shaft assembly into the shallow groove and place the 0-ring seal in position as shown. (ill. 3) Spin the rotor, it should turn freely. • Turn the motor so the control box is in the desired orientation. Lift the motor, line up ill.3 the bolt holes and gently slip the motor over the rotor/shaft assembly being sure that the motor and rotor/shaft assembly are aligned. Once aligned the motor housing face will make contact with the pump housing face. NOTE: is Clearances between the pump housing and the motor housing are very tight. To ensure proper fit it is important to gently manuver the 'ON* motor housing into the casing. DO NOT use force to insert the motor housing into the pump housing! IC • Insert the bolts and tighten in a cross pattern. -,Nk. ,1Er) \ v • Install into piping and skip to 8.1.3 ill.4 .. 04/06/?�018 ASPEN BUILDING DEPARTMENT 8.1.2 If the pump is already installed in the piping • Remove the 4 bolts (516" or 8mm hex wrench required) and try rotating the motor without backing it out from the pump casing. Try cracking the motor approximately .020" using a screwdriver between the motor and pump housing and try turning the motor. • If motor will not move, remove motor completely. Remove impeller, rotor, and rotor can from the motor. Note: Rotor and impeller assembly will come out first. Remove rotor can from motor and put aside. • Install impeller and rotor assembly into pump. • While holding rotor, install 0-ring in casing,and then slide rotor can over rotor and slide all the way in. • Rotor and rotor can should stay in place while you pick up the motor. If they do not, start over to assure 0-ring is properly located and have someone hold the assembly in place with a screwdriver on top of the plate. • Pick up the motor with the terminals properly orientated and carefully start to slide the motor over the rotor can. The resistance of the sliding will keep the rotor and rotor can assembly in place and the screwdriver can be moved. Note: Do not allow the motor to droop or the 0-ring might move out of position. • Line up the bolt holes, reinstall the bolts, and tighten in a cross-pattern. 8.1.3. After Installation into piping • Carefully open shutoff valves and check for leaks. • Make sure that the electrical box cover is mounted and that all cable glands are installed to prevent dust and particles from contaminating the electrical box. • Before starting the pump, the system (and pump) must be filled with fluid, and air completely bled out of the system. For proper operation, pressure must be maintained on the suction side of the pump.The pump does not have screws for bleeding the air, as it is automatically bled as a function of the design of the pump. Temporary air in the pump will generate noise that disappears after a short time. WARNING! • The maximum system pressure is 145 psi (1 MPa or 10 Bar) • The pump must always be filled with system fluid as it is water lubricated and water cooled • The motor stator openings and stator housing (Figure 7) should not be insulated since the thermal insulation may prevent motor cooling and prohibit condensate from escaping from the motor housing when used in high humidity environments where the fluid temperature is below the motor temperature. RECEIVED 04/06/2018 7 ASPEN BUILDING DEPARTMENT 9. ELECTRICAL CONNECTIONS Connection of the pump must comply with local electrical codes and be carried out by qualified personnel. Connection to the power supply is carried out with the enclosed connector, the mounting of which is shown in the picture accompanying the connector. When connecting the pump,the following must be considered: • Liquid tight power connection required to maintain IP44 enclosure rating. Use supplied thread adapter option for flexible or armored cable installations. • The power input cable must use a minimum wire size of 16AWG solid or multi-strand copper wire. • Local or national electrical code requirements supersede Taco's specification. • Install an electrical disconnect to comply with national electrical code. • Connection of the power supply electrical cable must be done in a manner that ensures it does not contact the motor housing and volute of the device, due to potential high temperatures of both. The pump has built-in over current fuse protection, temperature protection, and basic overvoltage protection. It does not require additional overload protection devices unless required by local electrical codes. Power supply cabling should be capable of carrying rated power and be properly fused. Grounding connection is essential for safety and should be connected first. Grounding is only meant for pump safety. System piping should be grounded separately. 10. SETUP AND OPERATION: 10.1 Control Panel Layout 1. Bar Display of Values 2. Numerical Display of Values 0 3. Unit Display of the Currently Selected Parameter(Watts, Head Setting, Flow, or Speed) II ift 4. Display of the Currently Selected Mode 0cp000000 ,5 ., o000000 ,,, 5. [+] Button °A G Q ��y, ' 6. [✓]Button 7. [-] Button 7 6 51 10.2 Switching the Pump On and Off When the pump is powered for the first time, it operates with the factory default settings in automatic mode. To switch the pump off, press and hold the [-] key for 5 seconds, until OFF is shown on the display. When the pump is switched off, the numerical display shows OFF. To turn the pump on, press the [-] key briefly. 10.3 Pump Functions [-] Key Short press: • Turn pump on • Scrolling through parameters downwards, not changing parameter values. • Scrolling through modes downwards when mode selection is selected. • Changing parameters downwards when setting parameter values. Long press: • 3 seconds together with [+] key to select night setback mode. • 5 seconds to switch off the pump. • 5 seconds together with [I]and [+]keys to restore pump to factory default settings. [I] Key Short press: • To confirm currently selected values of both mode and parameter. Long press: \,0'- 1 �'\ ' , fl `i! • • 3 seconds to enable mode selection. ' • 5 seconds together with long press on [+] and [-] keys to restore pump to factory d0f4tnt0 18 8 ASPEN BUILDING DEPARTMENT [+] Key Short press: • Scrolling through parameters upwards, not changing parameter values. • Scrolling through modes upwards when mode selection is selected. • Changing parameters downwards when setting parameter values. Long press: • 3 seconds together with [—] key to enable night setback mode. • 5 seconds together with[✓]and [—] keys to restore pump to factory default settings. 10.4 Operation and Mode Selection Once the desired mode is selected, the factory default parameter is displayed numerical display(except for Auto Mode). If required, the parameter value can be changed with the [+] or [—] key, then confirm the parameter setting by pressing the [✓] key. To activate or deactivate the night setback feature, simultaneously press and hold the [+] and [—] keys for 3 seconds. To scroll through the parameter values within a mode, use the [+] or [—] keys. The desired parameter is selected (see individual mode) with the [✓] key. The parameter value is then selected using the [+] or [—] keys. The selected value is confirmed using the [✓] key. 10 5 Mode Descriptions The pump can operate in 5 different modes.We can set the pump in the most appropriate mode,depending on the system where the pump operates. The pump modes are: • Automatic Mode(factory default) • Proportional Pressure (increased differential head as flow increases) • Constant Pressure(constant pressure as flow increased) • Constant Speed(user selectable to match system requirements) • Combined Mode(all mode indicators are off) To switch between modes (except night mode) press and hold the [✓]key for 3 seconds then select [+]or[—]key.Once desired mode is selected,press the[i]key to confirm. • H Automatic Mode In automatic mode the pump automatically sets the operating pressure, depending on the hydraulic Max Hset system. By doing so,the pump finds the optimal operating position. The parameters cannot be set;they can only be scrolled through.This mode is recommended in most systems. Hset'HQ% Proportional Pressure ► The pump maintains the pressure with relation to the current flow.The pressure is equal to the set Proportional Pressure pressure(Hset on the drawing)at maximum power; at 0 flow it is equal to HQ %(default 50%, HQ %can be set on the pump webpage)of the set pressure. In between,the pressure changes linearly, relative to H A the flow. In regulated mode we can only set the pump pressure(Hset on the drawing).We can only scroll through the other parameters. Constant PressureThe pump maintains the currently set pressure(Hset on the drawing),from 0 flow to maximum power, Min. where the pressure begins to drop.At constant pressure,we can only set the pressure(Hset on the drawing)which the pump will maintain.We can only scroll through the other parameters. Constant Pressure Constant Speed The pump operates with the currently set speed(RPMset on the drawing). In the unregulated mode,we H can only set the speed at which the pump will operate.We can only scroll through the other parameters. Combined Mode 4,„ Multiple limits can be set only over the web interface. None of the other modes are on. ASP NightMode • When the pump operates in night mode, it automatically switches between the selected Constant Speed operating mode and night curve. The transition to the night mode depends on the fluid temperature in the system.When the night mode is enabled, its icon illuminates and the pump operates in the selected operating curve of the mode.When the pump identifies the media temperature falling by 60 to 70 F° (15-20 C°)over a 2 hour time perio. - c• E ivED starts to blink and the pump switches to the night curve.When the fluid temperature rises again, the icon stops bli �. the pump switches to the operating curve in the selected operating mode. The night mode operates only in combi ." b I th the above indicated modes. It is not an independent operating mode. 0 4/0 6/2 018 ASPEN BUILDING DEPARTMENT 10.6 Restoring Factory Settings To restore factory defaults, press and hold all three buttons for 5 seconds. The pump will be set to the automatic mode of operation.Any previously set values for pressure and RPM will be deleted. 11.SPECIFICATIONS 11.1 Application: •Maximum Operating Pressure: 175 PSI (12 bar) • Water Temperature Range: 36°—230°F (2.2°— 110°C) •Ambient Operation Temperature Range: 32°— 104°F (0°—40°C). Ambient temperature should be 104°F (40°C) or lower when fluid temperature exceeds 194°F (90°C). • Relative Humidity: Max. 95% • Designed for closed loop heating and cooling systems pumping water or a water/glycol mixture. • NPSHr-Minimum static inlet pressure at pump suction to avoid damage to the bearing assembly: FLUID VRI5&VR20 VR25&VR30 TEMPERATURES (PSI/bar) (PSI/bar) 112°F(50°C) 7.3/0.5 4.35/0.3 176°F(80°C) 11.6/0.8 14.5/ 1.0 230°F(110°C) 20.3/ 1.4 23.2/ 1.6 • For indoor use only- employer uniquement a l'interieur. 11.2 Electrical Ratings: 1 phase,110-240V,47-63Hz(VR15&VR20) Pump Ratings 1 phase,2 30-240V,47-63Hz(VR25&VR30) VR15=0.027-0.68 HP PowerConsumption(HP) VR20=0.035 1.088HP VR25=0.054-1.496 HP VR30=0.054-2.175 HP VR15=20-500W PowerConsumption(W) VR20=26-800W VR25=46-1100W VR30=40-1550W VR15=5.6-2.8A Rated Current VR20=7.2-3.6A (lphase,230V) VR25=5.3A VR30=7.2A VR15&VR20=6A Current Limit(Max.) VR25&VR30=8A 24VSuppI Output Max.Current upto100mA,0utputVoltage of24V±20%,Output Ripple under 1V RelayOutput: 8A,Max.Voltage 250VAC, 48VDC Max. Load upto 500VA Max.InputVoltage=32VDC Digital Inputs: 2 Inputs&1 Output Logical»1«Voltage>8V,Logical»0«Voltage<2V Con n ector=RJ-45 Ethernet: Services=httpserverand client,FTP server RECEIVED 04/06/3)018 ASPEN BUILDING DEPARTMENT 11.3 Standards, Protection and Connection: • Insulation:ClassH • Enclosure:Class2,IP44 • Integrated Motor Protection(electronically protected) • Continuous Duty • UL778,1004-1,508C • CAN/CSAC22.2#108,#100,#107.1EMC(89/366EEC):EN61000 • LVD(73/23/EC):EN60335-1,EN60335-2-51 • Machine Safety(98/37/EC):EN ISO 12100 • FlangeConnections:ANS14-bolt 11.4 Materials of Constructin: • Casing Cast Iron,Cataphoresis Coated • Impeller Stainless Steel • Shaft Stainless Steel • Bearing Metal Impregnated Carbon RECEIVED 04/06/2018 ASPEN 11 BUILDING DEPARTMENT Section 2. Controller Operation 12. FEATURES This section describes the controller features for VR15-3 through VR 30-3 range of pumps. The controller is used for various remote control applications, including: • Remote on/off • Analog 0..10 V voltage control • Modbus remote control • Status relay feedback • Web access over Ethernet There are several possible connection configurations. Not all functions can be used simultaneously. — • on/off + 0..10 V + relay output 11 • Modbus RTU + Relay output • Ethernet + on/off + 0..10 • Modbus RTU + Ethernet • Ethernet + on/off + relay output N 12.1 Specifications Below is an overview of Controller specifications. For details, please refer to appropriate sections of this manual. GENERAL DATA Ambient humidity <95% relative, non-condensing Also see appropriate pump data for other ambient specifications. Power supply and 5 V@500 mA supplied by the pump 6-pin connector further extended for display. connection RECEIVED 04/06/2018 12 ASPEN BUILDING DEPARTMENT MODBUS SPECIFICATIONS Data protocol Modbus RTU Modbus connector Screw-less terminals 2+1 pins. See section 16.3"Connection to Modbus" Modbus connection type RS-485 Modbus wire configuration Two-wire+common Conductors:A, B and COM(Common). See section 16.3"Connection to Modbus". Communication transceiver Integrated, 1/8 of standard load Connect either via passive taps or daisy chain. Maximum cable length 1200 m See section 16.5"Termination". Slave address 1-247 Default is 245, settable over Modbus. See section 16.4"Speed, parity and address". Line termination is not integrated. For low Line termination Not present speed/short distance,termination can be omitted. Otherwise, terminate the line externally on both ends. Supported transmission 1200,2400,4800,9600, Settable over Modbus register[default=19200]. speeds 19200, 38400 baud Start bit 1 Fixed. Data bits 8 Fixed. Stop bits 1 or 2 1 stop bit minimum, up to 2 when parity not enabled [default=1] Parity bit Even/odd/none [default=Even] Flashing yellow when data reception detected. Modbus visual diagnostics LED2 Combined (OR)with Ethernet ACT function. Maximum number of Limited by possible Modbus addresses to 247. Modbus devices 247 1/8 nominal load enables 256 devices. Maximum Modbus packet size 256 bytes Including address(1)and CRC(2)bytes. Isolation Common ground (COM) Modbus shares common ground with other signals. with SET1, SET2 and SET3. ETHERNET SPECIFICATIONS Ethernet connector RJ-45 10BASE-T, 10Mbit/s connection. Connection type - Web server(port 80) and services - Firmware update over web interface - Optional Modbus RTU over TCP/IP Default IP address 192.168.0.245 192.168.0.246 for right twin pump. Ethernet visual LED1 /LINK Slowly blinking when module is powered, permanently lid diagnostics when link established. LED2/ACT Flashing yellow when data reception detected. Combined (OR)with Modbus data reception indication. MODE SELECTION SWITCH Adjustment 10 position rotary switch Position read at power-on. Used for relay configuration and module configuration reset. RECEI Eta 04/06/2018 13 ASPEN BUILDING DEPARTMENT Analog signals(SET1,SET2, SET3) Input voltage range -1 to 32 VDC When used as input. Output voltage range 0 to12 V When used as output. 5 mA max. Load allowed per output. Input resistance —100 kO2 0.5 mA load is added for most configurations. Output current sink range 0 to 33 mA(4-20 mA) Current sink to COM if configured as output. Relay specifications Connection type Screw-less terminals Rating - 250 VAC,8A Potential free changeover contact. 48VDC, Max Load Upto 500VA 13. CONTROLLER LAYOUT — T - ETHERNET LED2 LED1 ACT LINK C00210 ❑❑ OCOEE r,sT.1\._,t C: .i:G,i-•. 0 u O > x >z �__itii1. ; z z N m 0 0 o MODE f— Z cl ~., m C Q N uO 1_ C D Z RELAY ANALOG RS 485 L - - - - L - 1 Terminal Designation Description MODE Mode selection rotary switch. Used to configure mode of operation for the circuit.See section 14.3"Module mode selection" LED1 /LINK Slowly blinking when module is powered. Blinking fast when Modbus Error. Permanently lid when Ethernet link established. Ethernet 10BASE-T RJ-45 connector. LED2/ACT Indicates Ethernet activity or Modbus activity. B/D- RS-485 negative data signal for Modbus. A/D+ RS-485 positive data signal for Modbus. SET1 /RUN Control signal 1. COM/OV RS-485 common and analog input common(ground). SET2/MAX Control signal 2. SET3/FB Control signal 3. NC Normally closed relay contact.Opens when relay is active. C Relay common contact. NO/OK Normally open relay contact.Closes when relay is active. RECEIVED 04/06/2018 14 ASPEN BUILDING DEPARTMENT 13.1 Connection Considerations • All cables connected must be heat-resistant to at least+185 °F. • All cables connected must be installed in accordance with The National Electric Code/NFPA 79/ EN 60204-1. • All wires to the communications module must be connected to the terminals or cut. No loose wiring permitted. WARNING! A • If voltages over 24 VAC/DC are possible on NO, C, NC terminals: • Wires should be routed so no wire crosses the center barrier. • Relay cable (NO, C, NC) must be separated from all other wiring with reinforced insulation. • Cable outer layer must not be stripped longer than 0.59 inches. See"Cabling preparation" below. WARNING! Before performing any work on the module, make sure that the pump and module electricity supply has been switched off and that it can- not be accidently switched on. RECEIVED 04/06/2018 15 ASPEN BUILDING DEPARTMENT 13.2 Connection Examples DEFAULT(FACTORY)CONFIGURATION T r— - ETHERNET LED2 LED1 ACT LINK HZL C COD �■ Z©©COO z z N f a a m o o MODE r Z G) Z rn '"' w OO m C 0 C A Z 0 RELAY ANALOG RS-485 L - - - - L - L - - - 1 RELAY AND MODBUS CONNECTION ETHERNET LED2 LEDI ACT HNK ZCV1 Ali [a �-�'oo is-11 , 1 z 2 > - g O g ♦ MODE d" m C 0 " 0 u D Z 0 I I ALARM Max Modbus signal Run RECEIVED 04/06/2018 16 ASPEN BUILDING DEPARTMENT RELAY AND ETHERNET CONNECTION — - - - - - - - - - - - -I ETHERNET LED2 LED1 ACT LINK 1771 ©2I/IV;� ❑❑❑ ❑ ❑❑ C❑❑ S1 000 OcxXxi COC _ ,) 0000C i u z > m 8 E MODC c o a z c O LI W o o 0 c z 0 r , , NOTE: 7/8"max length Ethernet connector recommended. The Ethernet connection has a sharp cable bend angle and reducing the connection terminal length reduces this problem. NOTE:To maintain pump IP protection, the network cable should be pulled through the gland inlet and then crimped to a connector. RECEIVED 04/06/2018 17 ASPEN BUILDING DEPARTMENT 14. CONTROL MODES AND PRIORITIES 14.1 Setting Priority Several signals will influence the pump operation. For this reason, settings have priorities as shown in the table below. If two or more functions are active at the same time, the one with highest priority will take precedence. Priority Pump control panel & External signals' Modbus control Ethernet settings 1 Stop (OFF) 2 Night mode active2 3 Max. RPM(Hi) 4 Min. curve4 5 Stop(Run not active) 6 Max. curve' Stop3 7 Set point setting4 Set point setting3 8 Set point setting4 Examples: • Stop on the pump display panel will stop the pump, regardless of external set point. • If External Run input is inactive,the pump cannot be started over Modbus, but can be set to max RPM on the display panel. 14.2 Control Variables Pump will respond to external controls according to selected pump operating mode. Consult proper pump operating manual for explanation. Symbol Regulation mode Module set point controls: Auto mode (RUN ONLY) OProportional pressure Maximum head ;.L ; Constant pressure Maximum head Constant speed Speed (RPM) Combined5 (Web interface only) ONight mode6 (RUN only) 'Not all inputs are available in all modes. 2External and Modbus Stop signals become active in night mode. Due to possible confusion, use of night mode is discouraged while using external control. 30n1y available when pump is bus controlled. 'Not available when pump is bus controlled. RECEIVED 'Multiple limits can be set. Not available on all pumps. 'Night mode is not independent regulation mode. 04/06/2018 18 ASPEN BUILDING DEPARTMENT 14.3 Module Mode Selection WARNING! Before performing any work on the module, make sure that the pump and module electricity supply has been switched off and that it cannot be accidently switched on. There is a mode selection rotary switch in the terminal box. It can be rotated by gently inserting a screwdriver into the arrow mark on top and rotating the switch to desired value. Mode switch Function Description position 0 Free configuration Terminal functions are configured over Ethernet interface. SET1 = RUN input SET2 = MAX input Mode 1 SET3 = FB(10.5 V)output, used to supply RUN and MAX inputs. 1 Factory Default External voltage source can also be used. RS-485 = Modbus interface. See section "14.4 Mode 1". Application: 0-10 VDC Speed or head control,external OFF SET1 = RUN input SET2 = SPEED input 2 Mode 2 SET3 = FB(10.5 V)output, used to supply RUN and MAX inputs. External 5-24 V voltage source can also be used. RS-485 = Modbus interface See section "14.5 Mode 2". 3...5 RESERVED Reserved for future or customer specific use. 6 Show relay LED1 and LED2 will show relay configuration. configuration See section "5 Relay output". Relay configuration will be increased (0->1, 1->2, 2->0)when electricity is turned on. 7 Change relay LED1 and LED2 will show current relay configuration. configuration See section "5 Relay output". Same as Mode 9,with exception of: 8 Twin reset to factory module IP address is set to 192.168.0.246 Twin IP address is set to 192.168.0.245 This mode will set communication interface to default values. Main purpose is to restore default settings. NOTE: • Disconnect any SET1, SET2 and SET3 connections when using this mode to 9 Reset to factory prevent possible harm to controller. SET1, SET2, SET3 will output test voltages of 10 V,7 V and 5 V respectively. RS-485 port is actively driven. Relay will cycle. This is used for testing purposes. • It is recommended that all module wires are disconnected to prevent possible harm to external controllers. RECEIVED 04/06/2018 19 ASPEN BUILDING DEPARTMENT 14.4 Mode 1 Mode 1 is most often used mode of operation. It has 2 pre-prepared inputs that can be used for either digital control or with analog control voltages.Additional 10.5V output provides voltage feedback for analog or digital control. Terminal designation Signal function SET1 /RUN RUN input. Signal load 0.5 mA. COM/OV Common ground for voltage input. SET2/MAX MAX input. Signal load 0.5 mA SET3/FB 10.5 V feedback voltage for SET1 and SET2. DIGITAL(SWITCH)CONTROL COMMON MODE 1 CONNECTION CONFIGURATIONS(SWITCH) ETHERNET LEDT LED1 ACT UNK i�2 6- z iii 2 O 00 1Z viaLi p ✓ u • V V O ? n 2 t 3 • . MOD rygt oommAm O 'SC $ s o c z r O L - - - -L ___ L _ 1 _ _ _ _I — . Max —\. Run RECEIVED 04/06/2018 20 ASPEN BUILDING DEPARTMENT Contact position Function Description RUN MAX SET 3/FB SET 3/FB Stop the pump The pump is stopped 1 l SET 1/RUN SET 2/MAX SET 3/FB SET 3/FB Start the pump The pump will run with internal set point SET 1/RUN SET 2/MAX Minimum curve The pump will run with minimal speed for selected regulation mode LQ. Maximum curve The pump will run with maximum speed form selected regulation mode RECEIVED 04/06/2018 21 ASPEN BUILDING DEPARTMENT ANALOG(SWITCH)CONTROL OPTIONAL MODE 1 CONNECTION CONFIGURATIONS(ANALOG) E IHLRL:L1 ETHERNET LE L.' LELt LED2 LUDI AC UNI:. ACT UNK n rya n rT IDELIILI O� C❑7 1 ❑C❑oC DDD 41 s. Qo� occ0c c ��) > d5g Z ry -. 2 - R ❑ n > MODE ti ` • y MUM PEE o " 8 " 8 _I L —► 4 J RUN a-IN /. RUN r I 1 r ETHERNET t1MERNEI LED2 LED,. UO2 LED1 ACT LINK ACT LINK I I I LE Q� iii41 • s„ � �„2 ,,_ KJ em OX� t m 8S N ` MODE '', Lei p t MOUE s G o ~ " m I_ — .L.57 q—+ I LJO__1 o-la RECEIVED 04/06/2018 ASPEN BUILDING DEPARTMENT RUN voltage MAX voltage Function <2 V < 1 V Pump stopped > 3 V < 1 V Internal regulation <2 V 2..10 V Minimum curve > 3V 2..10V H [m] /• n[RPM] H max/ Hmax H/ n 11 I I Hrnin/ ninin Hmin= 15%Hmax Hmin=25%Hmax Off 1 2 3 10 U[V] Figure 1: External 2..10 V transfer curve for Mode 1 0..10 V H [m] /A (RUN+MAX) n[RPM] H max/ Hmax Hmin/ Hmin I t Hmin= 15% Hmax Imin = 25% Hmax Off 1 2 3 10 U[V] RECEIVED Figure 2: External 0..10 V transfer curve for Mode 1 e/ 04/06/2018 ASPEN BUILDING DEPARTMENT 14.5 Mode 2 Mode 2 is used for external 0..10V voltage control. Terminal designation Signal function SET1 /RUN RUN input. Signal load 0.5 mA. COM/OV Common ground for voltage input. SET2/MAX SPEED input. Signal load 0.5 mA SET3/FB 10.5 V feedback voltage for SET1 and SET2. MODE 2 CONNECTION CONFIGURATIONS LID` uoi i b< uoa PUN RUN voltage MAX voltage Function <2 V 0..10 V Pump stopped >3V 0..10V H[m] n[RPMr Figure 3: External 0..10 V transfer curve for Mode 2 Hm./nm.. Hmin=15%H„,„ =25%n„. Hmn/nmin Off 0.5 10 u[v] 15. RELAY OUTPUT Terminal designation Terminal description MODE Mode selection rotary switch. Used to show and configure mode of operation for relay. LED1 /LINK Slowly blinking when module is powered, permanently lid when link established'. LED2/ACT Flashing yellow when data reception detected. Combined (OR)with Modbus data reception indication'. NC Normally closed relay contact.Opens when relay is active. C Relay common contact. RECEIVED NO/OK Normally open relay contact. Closes when relay is active. The module contains one status relay, used to signal pump operation or malfunction. See table following for functionality. 0 4/0 6/20 18 ASPEN BUILDING DEPARTMENT Relay Output Relay LED status' configuration status Description position LED 1 LED 2 0 Error Only active when the pump is powered up and detects a problem �O_ O [default] with operation. 1 NC NO C 1 1 Ready The relay signal is active when the pump is ready for operation. Q �O NC NO C I 1 \ 1 / \ 1 / 2 Operation The relay signal is active as long as the pump is operating. If the .O. .O pump comes to a stop or an error occurs, relay will deactivate. / 1 / 1 NC NO C Relay output not active. NC NO C Relay configuration number can be modified by either the web interface, Modbus register 012 or the Mode switch. 16. . ETHERNET Terminal designation Description MODE Can be used to reset network configuration LED1 /LINK Slowly blinking when module is powered, permanently lid when link established. Ethernet 10BASE-T RJ-45 connector. LED2/ACT Indicates Ethernet activity or Modbus reception. The communications module has a built in web server which allows you to access your pump directly from an existing Ethernet network. Direct connection to a computer is also possible with a crossover cable. The web server uses HTML pages to set/view: • Regulation mode settings • Regulation parameters(power, RPM, head,flow,efficiency) • Relay settings • External control inputs • Current and previews error • Pump statistics(power consumption, run time and other). 'When mode Mode 6 or Mode 7 is selected, LED1 and LED2 will show relay configuration. See section "4.3 Module mode selection" I I LED is on RECEIVED LED is off 0 04/06/2018 25 ASPEN BUILDING DEPARTMENT 16.1 Bus Topology 111 :nuns: Figure 4: connecting to a computer with a crossover cable Figure 5: connecting to a network via router 16.2 Connection to a Pump Ad-Hoc When connecting directly with the computer, Ethernet must be used to connect with the pump.The pump can then be accessed by typing IP address"192.168.0.245"or"00e" (or"192.168.0.246"or"00e2" if it is a left twin pump)in to your web browsers address bar. The computer must be set up to have a dynamic IP address. 16.3 Connection to a Pump via Router When connecting via a router, Ethernet must be used to connect with the pump. The pump can then be accessed by typing IP address"192.168.0.245"or"00e"or"192.168.0.246"or"00e2" if it's a left twin pump in to your web browser's address bar.The computer must be set up to have a dynamic IP address. 16.4 Pump Configuration over Ethernet Pump configuration is possible via HTML pages that offer different options: 1. Overview(default page when you connect to the pump,web page OVERVIEW)displays pump operation summary i.e.: • Operating mode, • Power consumption, • Head, • Estimated flow, • RPM • Estimated efficiency, • Priority set point, • Mode switch position • Input/output status • Replay status • Error code •Twin pump status • Night mode status • Motor temperature • Heat sink temperature, RECEIVED • Number of restarts. e� 04/06/2018 26 ASPEN BUILDING DEPARTMENT 2. Pump settings(web page PUMP) is meant to provide regulation and control (input and output)settings. It has control over: • Operation mode • Head limit(depending on pump mode) • RPM limit(depending on pump mode), • Ratio between head and flow HQ (depending on pump mode) • Input/output control. • Relay control. Setting can be saved to permanent memory by pressing the SAVE button. 3. Network settings(web page NETWORK)provide a way to change network configuration: • NetBIOS name-is a local network name service. Instead of'192.168.0.245'you can for example use 'http://00e'. Default: 00e, • Pump IP address- is a pump network address.The pump is seen as http server on this address, default: 192.168.0.245, • DHCP server- provides lease for"point to point"connection (cross-over cable to computer for example).Will disable itself if another DHCP server is found, • DHCP client will automatically acquire DHCP address from the network, • Default gateway—provides connection route to larger networks.This is usually a router address, default: 192.168.0.1, • Subnet mask-sets subnet address range that is on the same subnet and can be reached directly.The rest of communication goes over the gateway, default: 255.255.255.0, • Twin mode with IP- will connect two pumps for alternating operation. When two pumps are configured for twin mode, they will switch about once per day. Setting this field to inexistent IP will disable this option! Set it so the first pump references the second and vice versa. Default: 192.168.0.246. Setting can be saved to permanent memory by pressing the SAVE button. 4. Log (web page LOG)displays possible previous and current errors. 5. MORE(web page MORE) has link to additional manuals and tools that might be available. Has an option to update NMTC modules software, by user inputted software file(available at your local serviceman or our webpage). RECEIVED 04/06/2018 27 ASPEN BUILDING DEPARTMENT 17. MODBUS 17.1 Modbus Related Interface Designation Description MODE Can be used to reset network configuration. LED2/ACT Indicates Ethernet activity or Modbus reception. B/D- RS-485 negative data signal for Modbus. A/D+ RS-485 positive data signal for Modbus. COM/OV RS-485 common and analog input common (ground). 17.2 Bus Topology The VR Control is a Modbus slave, connected directly to a Modbus RTU network. Connection can be made in either daisy chain style (if cabling allows such a connection)or a limited length passive tap. Schematic example is in Figure 6. Slave 1 Master Slave 2 Slave 3 55. r 5 CI) rp O rD 0 0 Passive tap Daisy chain Figure 6: Example of Modbus network Typically,only one master device is connected to the serial bus, and one or several slaves are also connected to the bus. Slaves do not communicate with each other and will never transmit data without receiving a proper request from the master device. Up to 32 single load devices can be connected to one RS-485 Modbus system without using a repeater.As this module is a 1/8 load device, up to 256 modules can be connected to the bus. Repeaters can be used to extend the maximum transmission distance and increase device count if needed. 17.3 Connection to Modbus A screened, twisted-pair cable should be used. The cable screen must be connected to the COM terminal and connected to safety ground at one point. 17.4 Speed, Party and Address By default, each device is set to 19200-E-1 (even parity), address 245. Properly set registers in section "7.7 Controller Configuration register block"to configure each device before connecting it to existing network. Optionally power each device one by one, configuring the settings before adding an-other one. There are several ways to restore forgotten Modbus connection settings: 1) Configure the module over Web interface. See section 6"Ethernet". 2) Reset the module to factory defaults. See Mode 9, section "4.3 Module mode selection". 3) If only address is unknown, Modbus"broadcast" (0x00)address can be used to write new address. Use care- fully as the value will be written to all connected devices. 17.5 Termination Control module contains neither termination nor bias circuitry. RS-485 wiring should be externally terminatecRrE( €IVED 04/06/2018 28 ASPEN BUILDING DEPARTMENT For short wiring and/or low baud rate, interface can operate without termination. However it is recommended that termination (-150 ohm resistor) is added on both ends of bus wiring. There are wiring length limits regarding to speed and termination: Maximum speed [baud] Maximum cable length [ft] 38400 4000,terminated cable 9600 4000 19200 1800 38400 900 NOTE:Any branch/derivative cable is considered unterminated. Keep them short, below 250m combined for maximum speed and reliability. 17.6 Register Block Overview Controller Modbus RTU registers are grouped in the following register blocks: Start address Register block Readable/Writable Description 001 Controller configuration R/W Configuration of the Controller module. 021 Controller status R Status registers for the Controller module. 101 Pump control R/W Pump control registers. 201 Pump status R Status data from the pump. 301 Pump data R Measured data from the pump. All addresses contain 16 bit(one Word) registers. Some are bit interpreted while others are combined for a 32 bit value. NOTE: All register addresses are 1-based.Address 001 is thus transmitted over bus as 0x0000. 17.7 Controller Configuration Register Block Registers in this block are read with either function codes 0x03 or 0x04.They can be written as holding registers with function codes 0x06 and Ox10. NOT :All values in this block are stored in nonvolatile memory immediately after write. NOTE: See section "4.3 Module mode selection" and use Mode 8 or 9 to restore default settings if you cannot access the controller after writing to these registers. RECEIVED 04/06/2018 29 ASPEN BUILDING DEPARTMENT Address Register name Range Resolution Description 001 SlaveDelay 0..10000 1 ms Delay in milliseconds for slave reply.This delay will be added to every Modbus reply[default=0]. 002 RESERVED 003 ModbusAddress 1..247 1 Modbus address[default=245]. Modbus transmission speed enumeration. 0 = 1200 baud 1 =2400 baud 004 BitRate 0..5 1 2 =4800 baud 3 = 9600 baud 4 = 19200 baud [default] 5 = 38400 baud 005..008 RESERVED Parity setting to be used for communication. 009 Parity 0..2 1 0 = No parity 1 = Even parity[default] 2 =Odd parity Stop bits used for communication.2 stop bits will only be 010 StopBits 1..2 2 used when "Parity"is set to 0. 1 = 1 stop bit[default] 2 =2 stop bits 011 RESERVED Configures module relay output. 0 = indicates fault 012 RelayControl 0..2 1 1 = indicates pump ready 2 = indicates pump operation See section "5 Relay output". 17.8 Controller Status Register Block Registers in this block are read with either function codes 0x03 or 0x04. They are read-only.This block can be used for various kinds of fault finding. Address Register name Resolution Description 021..022 RESERVED 023 SoftwareVersion 0.1 Module software version 024..029 RESERVED 030 ProductVersion 1 Product version [32x for NMTC module,x denotes hardware revision] 031 RESERVED 032 SoftwareVersion 0.1 Module software version [10= 1.0] RECEIVED 04/06/2018 30 ASPEN BUILDING DEPARTMENT 17.9 Pump Control Register Block Registers in this block are read with either function codes 0x03 or 0x04. They can be written as holding registers with function codes 0x06 and Ox10 Address Register name Range Description 101 ControlReg b0: Control bit that sets local or remote control. Setting this bit will enable pump RemoteAccess control over Modbus. 0 = Local 1 = Remote(controlled by Modbus master). b1: Control bit that switches the pump on or off. OnOffReq 0 = Off(stop) 1 = On (start). b2..15: - RESERVED 102 AltControlMode Alternative Control mode. Use of register 108 is preferred. Sets the control mode enumeration. 0 =ConstantRPM 1 =ConstantRPM 3 =ConstantHead 4 =ConstantHead 5 =ConstantHead 6 = ProportionalHead 128 =AutoHeadMode NOTE:values outside this range reserved. 103 OperationMode RESERVED 104 SetPoint 0.. Sets desired pump set point. 10000 0 will stop the pump. 10000 will set the pump to maximum output for desired mode. Values outside of valid range will cause the pump to operate with front panel set values. 105 RelayControl 0..2 Configures relay output. 0 = indicates fault 1 = indicates pump ready 2 = indicates pump operation See section "5 Relay output". 106...107 RESERVED 108 ControlMode 0..3 Sets the pump control mode. 0 =AutoHeadMode(Automatic head mode) 1 = ProportionalHead (Head proportional to flow) 2 = ConstantHead (Head is kept constant) 3 = ConstantRPM(Speed is kept constant) NOTE:values outside this range reserved. See section"4.2 Control variables"for exact parameter to be controlled. RECEIVED 04/06/2018 31 ASPEN BUILDING DEPARTMENT 17.10 Pump Status Register Block Registers in this block can be read by means of function codes 0x03 and/or 0x04.They are read-only. Address Register name Description 201 StatusReg b0..b5: - RESERVED b6: Rotation Indicates if the pump is rotating (running)or not. 0= No rotation 1 = Rotation. b7: RESERVED Bit 8: Indicates if the pump is locally or remotely controlled. AccessMode 0 = Local (a source with higher priority controls the pump) 1 = Remote(controlled by Modbus master). Bit 9: IsOn Indicates if the pump is on or off. 0=Off 1 =On It not necessarily indicate rotation as an error might stop the pump. Bit 10: Error Indicates if there is a problem with proper operation. 0= No problem 1 = Error present. Pump might still run. Bit 11: - RESERVED Bit 12: - RESERVED Bit 13: Indicates if the pump is running near maximum speed. NearMaxSpeed 0 = No 1 =Yes. This flag is set when power or speed is over 95%of rated maximum. Bit 14: - RESERVED Bit 15: Indicates if the pump is running near minimum speed. NearMinSpeed 0= No 1 =Yes. This flag is set when speed falls below 1/3 of rated maximum. 202 RESERVED (TBD) 203 ControlMode Indicates the actual control mode. 0= ConstantRPM 1 = ConstantRPM 3=ConstantHead 4=ConstantHead 5= ConstantHead 6= ProportionalHead 128=AutoHeadMode. 204 RESERVED 205 ErrorCodel Current first error code. 0 when pump is operating without problems. ED This value will always be non-zero when there is an error pRE r vEli/ section"8.1 Error codes"for code details. 04/06/2018 32 ASPEN BUILDING DEPARTMENT 206 ErrorCode2 Second error code. Non-zero when there is more than one error. See section "8.1 Error codes"for code details. 207 ErrorCode3 Third error code. Non-zero when there is more than two errors. See section "8.1 Error codes"for code details. 208 Control Mode Indicates the actual control mode. 0=AutoHeadMode(Automatic head mode) 1 = ProportionalHead (Head proportional to flow) 2= ConstantHead (Head is kept constant) 3= ConstantRPM(Speed is kept constant). NOTE: values outside this range reserved. See section"4.2 Control variables"for exact parameter to be controlled. 17.11 Pump Data Register Block Registers in this block can be read by means of function codes 0x03 and/or 0x04.They are read-only. Modbus Register name Range Resolution Description address 301 Head 0.01 m Pump head estimation in meters of water column. 302 Flow 0.1 m3/h Pump flow estimation. 303 Efficiency 0.01 % Estimated pump efficiency. 304 Speed 1 rpm Motor speed. 305 Frequency 0.1 Hz Motor frequency [100.0 Hz for 3000 rpm and 4 pole motor]. 306..307 RESERVED 308 ActualSetPoint 0..10000 0.01 % Indicates actual set point of the pump. (-1 for internal pump regulation). tbd 309..311 RESERVED 312 PowerHl 0..232 1 W Total power consumption of the system. 313 PowerLO 314..317 RESERVED 318 CircuitTemp -5500.. 0.01 °C Power electronics hotspot temperature. 16000 319 MotorTemp -5500.. 0.01 °C Motor compartment temperature. 16000 320..321 RESERVED 322 LiquidTemp -5500.. 0.01 °C Liquid temperature. 16000 323..326 RESERVED 327 OperationTimeHl Total operation time(above zero speed)of the 328 OperationTimeLO 1 hour pump.8 329 TotalPoweredTimeHl 1 hour Total power-on time of the module.8 330 TotalPoweredTimeLO 331 RESERVED 332 EnergyHl 333 EnergyLO 1 kWh Total energy consumption of the system.8 RECEIVED 8 Not available on all models. 04/06/2018 33 ASPEN BUILDING DEPARTMENT 18. FAULT FINDING 19.1 Error Codes The following codes will show up on display panel and on the appropriate Modbus registers to help you diagnose the cause of improper operation. Error code Description Probable cause E1x Load errors E10(drY) Low motor load Low load detected. Pump is running dry. El1 High motor load Motor might be faulty or viscous medium is present. E2x Protection active E22(hot) Converter temperature limit Circuit is too hot and power was reduced to less than 2/3 of rated power. E23 Converter temperature protection Circuit is too hot to run, pump stopped. E24 Converter overcurrent Hardware overcurrent protection triggered. E25 Overvoltage Line voltage is too high. E26 Undervoltage Line voltage is too low for proper operation. E3x Pump errors E31 Software motor protection active Average motor current was too high, pump load is much higher than expected. E4x Device specific error codes Electrical circuitry did not pass self-test. E40 General frequency converter error One of the display segment diodes is faulty(open/short). E42(LED) LED faulty Display board does not detect proper connection to main board, but power supply is present. E43 (con) Communications failed Voltage on DC link shunt(R34)not in expected range. During MFG.TEST,this is 10 kf2, 1% E44 DC link current offset resistor for 10°C..30 °C During operation, expected values are-55 °C..150 °C. E45 Motor temperature outside limits During MFG.TEST,this is 0°C..50°C.During operation, expected values are-55°C..150 °C. E46 Circuit temperature outside limits During MFG.TEST,this is 0°C..50°C. During operation, expected values are-55°C..150 °C. E47 Voltage reference outside limits. Comparison between internal references does not match. E48 15V outside limits 15 V supply not 15 V. E49 Test load does not match No test load detected or current measurement does not work properly(MFG.TEST). E5x Motor error codes E51 Motor parameters out of range Motor does not operate as expected. E52 Thermal Protection Active Motor Temperature is too high. Pump not operating E53 Invalid Model Selected Pump model not valid or out of range RECEIVED 04/06/2018 34 ASPEN BUILDING DEPARTMENT 00e VR15-30-3 ECM High-Efficiency Circulators -aco I.lrj. com ort_/S 1& i- PERFORMANCE A tea ianfy CangmY (Ipm) 0 100 -00 300 400 50 • 45 __.: ...._ 14 • VR15-3 40 - _ 12 35 Li - 10 o 30 v _ - 8 25 E 1 20 = 6 15 = - 4 10 = 5 - - 2 C 0 0 10 20 3,0 le, 50 00 700 80 ::213 100 110 120 Flow (gpm) (Ipm) 0 100 20,0 300 40C 500 600 700 50 I I I I I I I 45 . - 14 4C _ - 12 _ : VR20-3 35 = i- .: - 10 a. 30 - . R 25 - - 8 E 1 20 = ; ... . - 6 15 - 4 C ___ 40 60 80 100 12O 140 160 180 200 Flow (gpm) RECEIVED 04/06/2018 ASPPN BUILDING DEPARTMENT —! OOe VR-15-30-3 ECM High-Efficiency Circulators aco OCArs covm forters:kw/6 PERFORMANCE AThvto...,CJ.w., MY:,,i,-r 1:,Ci:iC Ji' (1Pm) 0 100 200 300 400 500 600 700 800 900 1000 1100 50 , 1 1 1 1 , _ , I I I 1 45 _ - . : VR25-3 14 40 - .......... ......... .........._ - 12 35 • - . - 10 .� _ - U 412 25 — - E 2 20 - _. : . .. ..: . . . .. . .......:. .. . . _ _ _ - - 6 15 ........... _ - 4 10 ‘ 5 = - - 2 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 Flow (gpm) (Ipm) 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 501 . . . I . . . . . l , . , • VR30-3 35 - 10 " 30 m 25 • : - 8 E 1 20 - 6 15 - 4 10 5 2 0 0 0 25 50 -E 100 125 150 175 200 225 250 275 300 325 350 Flow (gpm) RECEIVED 04/06/2018 36 ASPEN BUILDING DEPARTMENT NOTES: LIMITED WARRANTY STATEMENT Taco,Inc.will repair or replace without charge(at tion of petroleum-based fluids or certain chemical TION OF THE EXPRESS WARRANTY SET the company's option)any product or part which additives to the systems,or other abuse,will not FORTH IN THE FIRST PARAGRAPH ABOVE. is proven defective under normal use within one be covered by this warranty. (1)year from the date of start-up or one(1)year If in doubt as to whether a particular substance is THE ABOVE WARRANTIES ARE IN LIEU OF and six (6) months from date of shipment suitable for use with a Taco product or part,or for ALL OTHER WARRANTIES, EXPRESS OR (whichever occurs first). any application restrictions,consult the applicable STATUTORY, OR ANY OTHER WARRANTY In order to obtain service under this warranty,it is Taco instruction sheets or contact Taco at[401- OBLIGATION ON THE PART OF TACO. the responsibility of the purchaser to promptly no- 942-8000]. TACO WILL NOT BE LIABLE FOR ANY SPE- tify the local Taco stocking distributor or Taco in Taco reserves the right to provide replacement writing and promptly deliver the subject product CIAL, INCIDENTAL, INDIRECT OR CONSE- products and parts which are substantially similar or part,delivery prepaid,to the stocking distribu- in design and functionally equivalent to the defec- tor. For assistance on warranty returns,the pur- tive product or part. Taco reserves the right to USE OF ITS PRODUCTS OR ANY INCIDENTAL chaser may either contact the local Taco stocking make changes in details of design, construction, COSTS OF REMOVING OR REPLACING DE- distributor or Taco. If the subject product or part or arrangement of materials of its products without FECTIVE PRODUCTS. contains no defect as covered in this warranty, notification. the purchaser will be billed for parts and labor This warranty gives the purchaser specific rights, charges in effect at time of factory examination TACO OFFERS THIS WARRANTY IN LIEU OF and the purchaser may have other rights which and repair. ALL OTHER EXPRESS WARRANTIES. ANY vary from state to state.Some states do not allow Any Taco product or part not installed or operated WARRANTY IMPLIED BY LAW INCLUDING limitations on how long an implied warranty lasts in conformity with Taco instructions or which has WARRANTIES OF MERCHANTABILITY OR FIT- or on the exclusion of incidental or consequential been subject to misuse,misapplication,the addi- NESS IS IN EFFECT ONLY FOR THE DURA- damages,so these limitations or exclusions may not apply to you. —is�'i0 Comfy tieSO/Ut/0/75-A Taco Family Company Taco,Inc„1160 Cranston Street,Cranston,RI 02920 I Tel:(401)942-8000 I FAX:(401)942-2360 c I\1E Taco(Canada),Ltd.,8450 Lawson Road,Suite#3,Milton,Ontario L9T 0J8 I Tel:(905)564-9422 l FAX:(905)564-9436 Visit our web site:www.TacoComfortcom l Printed in USA I ©2017 Taco,Inc -- -_--- 04/06/2018 ASPEN BUILDING DEPARTMENT ESR-2053 I Most Widely Accepted and Trusted Page 3 of 4 TABLE 1—ROOF CLASSIFICATION OF ASSEMBLIES INCORPORATING VERSASHIELD°FIRE-RESISTANT ROOF DECK PROTECTION ROOF COVERING2 SUBSTRATE UNDERLAYMENT1 ROOF MAXIMUM CLASSIFICATION SLOPE Class A asphalt glass fiber shingle 15/3rinch plywood One layer VersaShield° A Unlimited Stone coated,steel,direct to deck, is/3rinch plywood or 0.013-inch thickness(0.330 mm), spaced sheathing One layer VersaShield° A Unlimited shingles or panels One layer VersaShield°,and 15/32 inch plywood or Steel direct to deck,0.013-inch spaced sheathing one layer Type 30 asphalt • A Unlimited thickness(0.330 mm),shingles or saturated organic felt panels 15/32-inch plywood or One layer VersaShield° B Unlimited spaced sheathing 75132-inch plywood or One layer VersaShield° A Unlimited spaced sheathing Existing wood shakes or Steel over battens,0.013-inch shingles installed over Two layers VersaShield° A Unlimited thickness(0.330 mm),shingles or spaced or solid sheathing panels Existing wood shakes or shingles installed over One layer VersaShield° B Unlimited spaced or solid sheathing Steel,0.016-inch thickness(0.406 15/3rinch plywood or ° mm),panels or standing seam spaced sheathing One layer VersaShield A Unlimited system 1'/3rinch plywood or One layer VersaShield°,and spaced sheathing one layer Type 30 asphalt A Unlimited saturated organic felt Existing wood shakes or shingles installed over Two layers of VersaShield° A Unlimited Copper,0.016-inch thicknPcc(0.406 spaced or solid sheathing mm),shingles or panels t5/3rinch plywood or ° spaced sheathing One layer VersaShield B Unlimited Existing wood shakes or shingles installed over One layer of VersaShield° B Unlimited spaced or solid sheathing 15/32-inch plywood or Two layers VersaShield° A Unlimited spaced sheathing Aluminum,0.018-inch(0.457 mm), 15/3rinch plywood or One layer VersaShield° B Unlimited shingles,panels,or standing seam spaced sheathing system Existing wood shakes or shingles installed over One layer VersaShield° B Unlimited spaced or solid sheathing t5/32-inch plywood Two layers VersaShield® A 11/2:12 TPO,CSM,CPA,EPDM,cap sheet, 15/,-inch plywood, ° or modified bitumen single-ply insulation Two layers VersaShiel,d A I 11/2:12 membranes 15/32-inch plywood One layer VersaShield° B 17/2:12 75/32-incih plywood Two layers VersaShield° A 2:12 PVC single-ply membrane 75/3rin io plywood, Two layers VersaShield° A 11/2:12 insulation 15/32-inch plywood One layer VersaShield® B 11/2:12 For SI: 1 inch=25.4 mm. 1Underlayment must be installed in accordance with Section 4.0 of this report 2Roof coverings must be recognized in a current 1CC-ES evaluation report.The roof covering must comply with the Class A or B flame-spread requirements of UL790(ASTM El 08),as applicable to the systems defined in this table. RECEIVED 04/06/2018 ASPEN BUILDING DEPARTMENT Halo LED H4 Collection WATERS FIXTURE A Trims 44 4" LED Square Downlight Baffle Trims s ' • Compatible with EL4 series(round)downlight light engines • Consistent O.D.with Halo 4"family • Square step baffle for controlled aperture brightness • Regressed Solite®flat glass lens • Wet Location, shower rated TLS408WHWB-Square baffle trim TLS408WHBB-Square baffle trim • Precision-formed aluminum baffles and die-cast trim rings offer with Solite®regressed lens,white with Solite®regressed lens,black high-quality fit and finish baffle,and white trim ring baffle,and white trim ring • Trim gasket provides AIR-TITETA4 seal, and compliance where local codes require a gasket on wet location, shower-rated trims L ...411LAP - i_iii, C I_3-3/8' TLS408SNBB-Square baffle trim with TLS408TBZBB-Square baffle trim [86 mm] 5-1/64" Solite®regressed lens,black baffle, with Solite®regressed lens,black [129 mm] and satin nickel trim ring baffle,and tuscan bronze trim ring 4" LED Wall Wash Downlight Trims • Wall wash optics with downlight performance • Two downlight reflector cone finish options: semi-specular clear and white • Precision-formed aluminum reflectors and die-cast trim rings offer high-quality fit and finish TL409WW-Semi-specular reflector TL409WHWW-White reflector with • High-reflectance vaccum-metalized specular wall wash kick with wall wash optic,diffusing lens, wall wash optic,diffusing lens,and reflector for high-angle vertical illumination and white trim ring white trim ring • Polymer diffusing dome lens for smooth distribution • Compatible with EL4 Series downlight light engines 27I14 [57mm] / \ • Wet location, shower rated L` 1 4-7/8" I [125 mm] 7-1/4' [184 mm] 14 4" LED Polymer "Dead Front" Shower Trim s • White polymer baffle and ring ,11,, / \ • Prismatic,clear flat polymer lens 143 rrrv,H • Non-electrically conductive"dead front" I [6-3/8' I • Non-corrosive front 6 5-1/64" • Wet Location, shower rated TL422PS-White polymer baffle and [129 mm] ring with prismatic clear polymer lens 4" LED Designer Trim Rings 111111111 • For use with TL4x round downlight trims only • Optional accessory • Die-cast trim ring • Thin profile provides subtle ceiling appearance(0.120"at OD and 0.180"at ID)TRM400PC Polished chrome RECEIVED TRM400BK Black TRM400WH White TRM400SN Satin nickel 0 4/0 6/2 018 - TRM400TBZ Tuscan bronze 6 ASPEN BUILDING DEPARTMENT WATERS FIXTURE A Halo LED H4 Collection Housings • Available for insulated ceilings`(ICAT)and non-insulated ceilings(TAT,TCP) • ICAT and TAT designated housings are AIR-TITETM in compliance with restricted airflow requirements per ASTM-E283 standard • Include standard Halo features: -Got Nail!TM Bar hangers with pre-installed nail and integral T-grid clip -Slide-N-SideTM wire traps and quick-connects for tool-less wiring outside the junction box -Pass-N-ThruTM bar hanger feature for tool-less shortening of bars without removal from frame • LED driver integral in the housing for optimized lumen delivery and superior thermal management • LED driver designed for high efficiency and long life-operating the LED package for over 50,000 hours • Dimmable -ICAT housings are dimmable to 10%in normal operation with most 120V leading edge(LE)and trailing edge(TE)phase control dimmers.May also dim to 5%using dimmers with low-end trim adjustment.(Consult dimmer manufacturer.) -Non-IC housings have two dimming options:phase control and 0-10V control.Phase control is dimmable to 10%in normal operation with most 120V leading edge(LE)and trailing edge(TE)phase control dimmers.0-10V is dimmable to 10%in typical operation with compatible 0-10V DC low voltage dimmers with two low voltage dimming wires.(Consult dimmer manufacturer.) • Can be operated from a standard wall switch if dimming is not required • Labels -cULus 1598 Listed Luminaire -cULus Listed for Damp Location,and wet location with designated trims • ENERGY STAR®Qualified with designated Halo H4 LED light engines and H4 LED trims" • May be used to meet State of California Title 24 and International Energy Conservation Code—IECC High Efficacy requirements with designated Halo H4 LED light engines and H4 LED trims" Energy Data / ICAT Housings • Minimum operating temperature: • Input frequency:50/60Hz -30°C/-22°F •THD:<20% • EMI/RFI Emissions FCC 47CFR Part 18,Consumer Limits • Input power: 13.0 W • Sound rating:Class A standards • Input current: 121 mA(120mA Remodel) • Input voltage: 120V • Dimmable:Leading edge(LE)and trailing edge(TE)phase control dimmers • Power factor:>0.90 H457ICAT1 E ICAT Rated/New Construction • For direct contact with insulation in insulated ceilings.` (May also be used in non-insulated ceilings.) • AIR-TITETM meets restricted airflow requirements per ASTM E-283 JILIMILli • Driver: 13W, 120V,50/60Hz • EMI/RFI: Rated for FCC Consumer Limits,suitable for residential and commercial 4111111.12111111— applications • Dimmable with most leading edge(LE)and trailing edge(TE)phase control dimmers to 10%(5%on select dimmers with low-end trim adjustment) • Dimensions:6"L x 8-1/2"W x 5-3/8"H(with 1/2"plaster lip)Ceiling cutout:4-1/2" H457RICAT1 E r ICAT Rated/Remodel y • Designed for installation from below the finished ceiling • For direct contact with insulation in insulated ceilings. (May also be used in non-insulated ceilings.) • AIR-TITETM meets restricted airflow requirements per ASTM E-283 • Driver: 13W, 120V,50/60Hz • EMI/RFI: Rated for FCC Consumer Limits,suitable for residential and commercial applications • Dimmable with most leading edge(LE)and trailing edge(TE)phase control dimmers to 10%(5%on select dimmers with low-end trim adjustment) • Dimensions: 14-3/4"L x 5"W x 5-1/2"H-Ceiling cutout:4-1/4" RECEIVED *ICAT housings are not for direct contact with spray foam insulation.Refer to NEMA LSD 57-2013. 0 4/0 6/2 018 **Refer to ENERGY STAR®Qualified Products List and CEC(T24)Appliance Database for listings. 10 ASPEN BUILDING DEPARTMENT BRINK - model:WS-776 WAC LIGHTING dweILEDTMLED Bath Responsible Lighting' 18„ Fixture Type: WATERS FIXTURE B *I 3" WS-77618 Catalog Number: Project: 24" 4313" Location: WS-77624 �� - — — 36" I 4013" WS-77636 PRODUCT DESCRIPTION SPECIFICATIONS Sleek style and bountiful light are what define the contemporary Brink Construction:Aluminum and White Acrylic LED bath vanity light from WAC Lighting.The thin bezel backplate Light Source:High output LED. contributes to the low-profile design of the Brink.Die cast metal endcaps and hardware house a co-extruded clear and white acrylic Finish:Brushed Aluminum(AL) shade which illuminates a superb amount of ambient light. FEATURES Standards:ETL&cETL damp location listed.ADA Compliant •Modern,sleek,clean •Ultra low profile design •Co-extruded clear and white acrylic provides substance,luminosity and optical efficacy •Mount vertically or horizontally •Driver located in standard 2"x 4"junction box •Conversion plate for 4"junction box included •Adjustable backplate •Universal driver(120V-220V-277V) •Color Temp:2700K,3000K,3500K •CRI:90 •Dimming:100%-5%ELV •Rated Life:85,000 hours •Input:120-277V ORDER NUMBER Color Temp Watt LED Lumens Delivered Lumens Finish WS-77618-27 2700K 15.5W 1155 910 WS-77618-30 3000K 15.5W 1225 1015 WS-77618-35 3500K 15.5W 1330 1115 WS-77624-27 2700K 20.5W 1595 1330 z. WS-77624-30 3000K 20.5W 1720 1440 AL BrushedAlumimum WS-77624-35 3500K 20.5W 1785 1510 WS-77636-27 2700K 30W 2365 1985 WS-77636-30 3000K 30W 2445 2095 WS-77636-35 3500K 30W 2561 2180 Example:WS-77618-30-AL RECEIVED waclighting.com Headquarters/Eastern Distribution Center Central Distribution Center Western Distribution Center Phone(800)526.2588 44 Harbor Park Drive 1600 Distribution Ct 1750 Archibald Av�C/0 6/2 018 Fax (800)526.2585 Port Washington,NY 11050 Lithia Springs,GA 30122 Ontario,CA 91760 WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. ASPEN BUILDING DEPARTMENT TYPE C GMLigh=g Project: WATERS FIXTURE C 12V DC LEDTASKTM Type: HIGH OUTPUT FLEXIBLE LED Location: LINEAR RIBBON Contact Phone: PRODUCT DESCRIPTION 5m/16.4' . 6mm A high lumen output flexible LED linear ribbon that conforms to 1.54 65 + straight,curved and irregular architectural coves, indoor steps o ® ® = ® S ® ® o ® 15187 and bannisters, interior recesses, undercabinet and task areas 24 1 and other constructs where even, energy saving high lumen 9m output LED illumination is specified. Available in a 5 meter Radius: (16.4') reel. Ribbon can be cut in field to achieve desired length. 180mm 7.08' PRODUCT SPECIFICATIONS Construction: LEDTask High Output Flexible LED Ribbon incorporates 300.16W LED diodes per reel and are mounted to a flexible copper buss.The ribbon is conveniently wound on a O % 5 meter(16.4 ft) reel. Each reel is shipped in a moisture proofNhi l if package and is also supplied with appropriate connectors. Connectors: C 4311)US Five meter reel includes 3-LTW-24 ribbon to power supply connectors,with 1 LTW-24 affixed to start of reel. ELECTRONIC POWER SUPPLIES Electrical: 19 LED's per foot. Each LED is.16W. 3.04W per DIMMABLE MAGNETIC POWER SUPPLIES foot. 5 meter reel is 4.0 amps. 50,000 hour LED life. Color Temperature: 3500K or 2700K warm white(WW). Cat. No. Description Kelvin temperature(color) 200K. LTP-2 2 Amp-Switchable- 120V Cord and Plug. Power Supplies: See chart at right for complete descriptions 12VDC @ 2 amps. Electronic. and catalog numbers. LTP-6 6 Amp-Switchable- 120V Cord and Plug. Dimming: Yes with dimmable power supplies(see at right) 12VDC @ 6 amps. Electronic. utilizing low voltage magnetic on/off wall dimmer(by others). LTH-2 2.1 Amp- 12V DC-25W Metal Chassis Hardwire Cutting and Mounting: Linear ribbon can be cut every Screw terminals three LEDs. Ribbon utilizes 3M double stick tape. LTH-4 4.2 Amp- 12V DC-50W Metal Chassis Hardwire Label: UL listed. Screw terminals LTH-8 8.5 Amp- 100W Metal Chassis Hardwire FLEXIBLE LED RIBBON CONNECTORS Screw terminals and mounting feet. Electronic. Cat. No. Description LTH-16 16.7 Amp-200W Metal Chassis Hardwire LTC-1 Ribbon to Ribbon Connector Screw terminals and mounting feet. Electronic. LTC-3 3" Flexible Ribbon to Ribbon Connector LTH-25 25 Amp-320W Metal Chassis Hardwire LTC-12 12" Flexible Ribbon to Ribbon Connector Screw terminals and mounting feet. Electronic. LTC-24 24" Flexible Ribbon to Ribbon Connector LTH-50-DIM Dimmable-Primary: 120VAC,60Hz, 0.33A LTC-36 36" Flexible Ribbon to Ribbon Connector Secondary: 12VAC, 12VDC,4A Max.50W LTC-60 60" Flexible Ribbon to Ribbon Connector LTH-60-DIM Dimmable-Primary: 120VAC,60Hz, 0.33A LTW-6 6" Flexible Ribbon to Power Supply Connector Secondary: 12V AC/DC, 12VDC,4A Max.60W LTW-24 24" Flexible Ribbon to Power Supply Connector LTW-48 48" Flexible Ribbon to Power Supply Connector LTHM-100-DIM Dimmable-Input: 120VAC, 60Hz, LTW-60 60" Flexible Ribbon to Power Supply Connector Output: 12VDC 8A Max. 100W, Nema 3R Enclosure For power supply dimensions,please see www.gmlighting.net Catalog No. Color Total LEDs LED Watts Amps per Reel Lumens per Ft.* Ribbon Length LED Life LTR300-27 2700K 300 0.16W 4 143 5 meters 50,000 hrs. Warm White 19 per ft. 3.04W per ft. 16.4 ft. LTR300-WW 3500K 300 0.16W 4 174 5'beim 50,000 Ins. Warm White 19 per ft. 3.04W per ft. 16.4 ft. `Kelvin temperature(color)±200. vE',i, ,o-a;,E r, 4,, ..,. .„, .., E! tI..ighIing GM Lighting, LLC • 9830 W. 190th St. • Unit F • Mokena, IL 60448 Toll Free: (866)671 0811 FAX: (708)478 2640 • www.gmlightintr y O 6/2 O18 e-mail: gmlightingllc@sbcglobal.net• Specifications subject to change without notice. 020111_IedtaoltialY Put N L_IN BUILDING DEPARTMENT TYPE C CHANNEL GMLighting Project: WATERS FIXTURE C ALUMINUM CHANNEL FOR Type: FLEXIBLE LED LINEAR RIBBON Location: Contact Phone: PRODUCT DESCRIPTION Extruded aluminum channel with snap-on frosted lens that provides a rigid,linear mounting platform for the following GM Lighting LEDTask Flexible LED Linear Ribbons: • LTR60 • LTR300 • LTR300-SO • LTR300-WP • SLR • LTR150-RGB Note: Aluminum channel will not accept LTRWP-RGB Wet Location Ribbon. MOUNTING ••• Channel screws directly into surface. Flexible LED linear ribbon uses attached 3M mounting tape. PLEASE ALLOW THE FOLLOWING CLEARANCE TO ALLOW FOR FLEXIBLE RIBBON TO RIBBON CONNECTORS LTR300-SO SERIES LTR300 SERIES: LTC CONNECTOR (1"3"12"24" LTR60/300WP SLR SERIES: LTR150-RGB SERIES 36"or 601 SERIES: SLC RTR LTCWP CONNECTOR CONNECTOR CONNECTOR (12"24" (12"24" 0 (12"24" 36"or60") 36"or 60") 36"or 60") 0 48" • 1 3/8"I MOUNTING HOLES ,I 6 H— O.C. I I I I I END VIEW Cat. Number Length Width Height Finish LED-CHL 48" 5/8" 3/8" Aluminum F• ix G ghting GM Lighting,LLC6 • 811 W 1 0th 70 )St.4 • Unit F • M 60448 Toll-Free:ng,(866)671-0811 FAX: (708) • Unit • Moken ,IL6www.gmlighting.net 0 4 0 6 2 018 Specifications subject to change without notice. LED-CHL_072012 ASPEN BUILDING DEPARTMENT Lir_ foster WATERS FIXTURETYPE C P.S.C transformer Co m p a ny The Standard of Quality Since 1937 http://www,foster-transformer.com 3820 colerain avenue• cincinnati,oh 45223-2586 • phone:(513)681-2420• fax:(513)681-2424• toll free:(800)963-9799 OP- o, - DIMMABLE LED POWER SUPPLY: otter C rL guionof 4110..HtERTgA' RoRS p �vgp4 UST y''w �a°°M°"°'>,qa Rig ( ( COMAE ED `.7 ETL Certified for North America' and CE marked for Europe. 7 Tested to ANSI/UL 60950-1, CAN/CSA C22.2 No. 60950-1-03' and EN 60950-1 . `7 Breakthrough Short Circuit & Overload Protection. Patented. 7 Limited Power Source Output allows for Class 2 wiring. 7 Multiple Input Voltages 120 V, 240 V, and 277 V, 50/60 Hz. `7 Output Configurable for 12 VDC or 24 VDC up to 60 W. 7 Can be dimmed with standard household dimmer. 7 No External Fusing Required. — 3 3/4 - `7 Can Withstand a Direct Short Circuit in Excess of 15 Days! 1 7 Transformer fully encapsulated for protection against the elements. I J CD — 1I Enclosure and Mounting Bracket 304 Stainless Steel _ I M 9/32 li) O] • I i F Epoxy Encapsulated for long life. I and protection from moisture. ��I = Nam;=_- ____ __________________11 1 -----------1 ---------------- Ili CO 1 I (--' 1 „) -0 roG II , , —o , o a Integral Wiring Compartment. with standard 1/2"conduit knockouts RECEIVED — #8-32 Ground Screw Provided 'Power supply is not registered with Electrical Safety Authority(ESA)for use in the province of Ontario, 0 4/0 6/2 018 Canada at this time. If ESA registration is required for your applicaiton, please contact the factory. ASPEN BUILDING DEPARTMENT STEP LIGHTS Model: WL-LED100 WAC LIGHTING LEDme® Step Light Responsible Lighting® Fixture Type: WATERS FIXTURE D Catalog Number: 5" r1Y2"i Y2'"NPTthreaded hole Project: Location: } I t7 } T 00 3" _8 2" 0 0 178" 1Y8" 1 2,8..-1 �— 21/2" 3/6" front side back PRODUCT DESCRIPTION Horizontal rectangle LEDme®Step Light.Designed for safety and style on stairways,patios,decks,balcony areas,walkways and building perimeters. Features an architectural design.Energy efficient for long-lasting indoor and outdoor lighting solutions.Creates an attractive,romantic impression at night. FEATURES SPECIFICATIONS • 316 marine grade cast stainless steel(SS)available Construction:Die-cast aluminum or 316 marine grade cast stainless steel • Direct wiring,no driver needed • Low profile,flush to wall aesthetics with no visible hardware Power:Direct wiring,no remote driver needed.Input voltage:120V or 277V AC 50/60Hz • Turtle friendly(AM,RD colors) • 40,000 hour rated life Light Source:3000K CCT Samsung HV-AC High Power LED,CRI:85 • Balanced lighting,free of shadows with minimum glare Optional color lenses.Total power consumption of 3.9W • Up to 200 fixtures can be connected in parallel Mounting: Fits into 2"x 4"J-Box with minimum inside dimensions of 3"L x 2"W x 2"H • Replaceable LED module • 5 year WAC Lighting product warranty Includes bracket for J-Box mount.See next page for spacing recommendations Dimming:Dim to 10%with electronic low voltage(ELV)dimmer Approved dimmers:Lutron Skylark SELV-300P-WH and Leviton Vizia VPEO4 FIXTURE PERFORMANCE Standards:IP66,UL&cUL Listed for wet locations Model# Lm Model# Lm Model# Lm Model# Lm Model# Lm WL-LED100-C-SS 45 WL-LED100-C-BK 31 WL-LED100-C-WT 68 WL-LED100-C-BN 31 WL-LED100-C-BZ 32 WL-LED100-AM-SS 28 WL-LED100-AM-BK 19 WL-LED100-AM-WT 38 WL-LED100-AM-BN 19 WL-LED100-AM-BZ 21 WL-LED100-RD-SS 3 WL-LED100-RD-BK 2 WL-LED100-RD-WT 4 WL-LED100-RD-BN 2 WL-LED100-RD-BZ 2 WL-LED100-BL-SS 5 WL-LED100-BL-BK 3 WL-LED100-BL-WT 8 WL-LED100-BL-BN 3 WL-LED100-BL-BZ 4 WL-LED100E-C-SS 37 WL-LED100E-C-BK 25 WL-LED100E-C-WT 58 WL-LED100E-C-BN 25 WL-LED100E-C-BZ 27 WL-LED100E-AM-SS 20 WL-LED100E-AM-BK 14 WL-LED100E-AM-WT 29 WL-LED100E-AM-BN 14 WL-LED100E-AM-BZ 15 WL-LED100E-RD-SS 2 WL-LED100E-RD-BK 1.5 WL-LED100E-RD-WT 3 WL-LED100E-RD-BN 1.5 WL-LED100E-RD-BZ 2 WL-LED100E-BL-SS 4 WL-LED100E-BL-BK 3 WL-LED100E-BL-WT 6 WL-LED100E-BL-BN 3 WL-LED100E-BL-BZ 3 ORDER NUMBER FINISHES Model# Color Finish 55 BK WT BN BZ C White 3000K SS Stainless SteelMir BK Black WL-LED100 120V 7CIVI Amber 61onm WT White WL-LED1 OOF 277V RD Red 640nm BN Brushed Nickel BL Blue 450nm lsZ Bronze Example: WL-LED100E-BL-SS RF^�� D WAC Lighting Headquarters/Eastern Distribution Center Western Distribution Center 7� www.waclighting.com 44 Harbor Park Drive•Port Washington,NY 11050 1750 Archibald Avenue•erpprjp(i9J/7 18 Phone(800)526.2588•Fax(800)526.2585 Phone(516)515.5000•Fax(516)515.5050 Phone(800)526.2588•Fax(g$00�tj)^^22 jj5 WAC Lighting retains the right to modify the design of our products at anytime as part of the company's continuous improvement program. NO V2Gq'PE N BUILDING DEPARTMENT WATERS FIXTURE E Click here to print this page SLIGHTING Heracleum II Pendant Light Item Code: MOI-HERACLEUM Description: Material(s): Nickel, Metal,Copper, 1 Polycarbonate 1 Dimensions: • 38.6"D X 25.6"H; 157.5"max overall height • Canopy:5.12"W X 4.3"H Lamp Type: LED )c ?\\ Bulbs: 63 LEDs,14W total; 5V DC;2700K • - (warm white);CRI 85;459 lumens(included) Listing:CUL, UL i Price: Price: $3,901.00 +Free Shipping Options: Model: Nickel Copper Design by Bertjan Pot Powered Through Electrosandwich®by Marcel Wanders,2010. By M000i. Decorative LED lamp inspired by the Heracleum Plant.The white leaves/lenses ramify from one branch creating a very technical, natural structure. By using the technique of coating conductive layers(Electrosandwich®),the lamp is very thin and delicate.A design not possible with normal wires.The Heracleum leaves are not frozen in one position.They can be freely re-positioned by rotating them around their stem. Heracleum II provides decorative ambient light. Metal wire frame, polycarbonate lenses and ultra-thin suspension wire. Offered in nickel or copper. Dimmable with a low voltage R,L type dimmer(incandescent/halogen). Driver located in the canopy. UL Listed. If you have questions,call(866)428 9289 RECEIVED 04/06/2018 ASPEN BUILDING DEPARTMENT WATERS FIXTURE F YLighting Cut Sheet Customize Information Print I Email Cut Sheet Change Your Info Upload Your Logo Printer Friendly Cut Sheet Change Client's Info Remove Your Logo Email Cut Sheet Price&Print Options 111 cut sheet Suspenders®48 Inch 4-Tier Tri-Bar LED Lighting System by SONNEMAN I YLighting https://www.ylighting.com/sonneman- suspenders-48 inch-4-tier-tri-bar-led-lighti ng- system.html Wattage: 54128.8141.4130.6140.8175.6164.8 %II Lamp Type: led Listing: UL 1 (� Price: 3140.00 , lb 4 Dimensions: Crystal Ladder Light(LL01)- Overall Dimensions:61"L X 61"W X 4, I 411 36"H;109"max overall height IMaterial: metal glass aluminum crystal acrylic 4. p� I / —NM 1 1 1 1111 1 1/' to / 1 1 1 i1 • 11 11 11 1 / 01 1 / 11 11 11 r III III • Suspenders®48 Inch 4-Tier Tri-Bar LED Lighting System by SONNEMAN I YLighting Company: Fixture Type: Chandeliers Date: 03/17/2018 Room: Placement: Project: Approved By: Prepared By: [Edit][Clear] Prepared For: [Edit][Clear] RECEIVED 04/06/2018 ASPEN BUILDING DEPARTMENT WATERS FIXTURE G Click here to print this page Suspenders 36 Inch 2-Bar In-Line Linear LED Lighting CLIGHTIN ,.. System - Bar-Mounted Single Cylinder/ Glass Diffuser Item Code: SON-SUS-36-IN-2-BAR-IN-LINE-LED-BMSC- GD Description: Material(s): Metal, Glass,Aluminum, Crystal Dimensions: • Overall Dimensions: 1.75"L X 73"W X 4"H;77"max overall height • Power Feed(Canopy):3.25"L X 2.25"W X 0.25"H Lamp Type: LED Bulbs: 8 X LED Luminaires(46.2W Fixture Total)-3020 Lumens,90 CRI,3000K, 120VAC (included) Listing: UL WIPrice: Now: $1,785.00 Compare:$2,100.00 • +Free Shipping • Options: Finish: Satin Black Bright Satin Aluminum The Suspenders®36 Inch 2-Bar In-Line Linear LED Lighting System-Bar-Mounted Single Cylinder/Glass Diffuser was designed by Robert Sonneman in 2017. Suspenders®36 Inch 2-Bar In-Line Linear LED Lighting System-Bar-Mounted Single Cylinder/Glass Diffuser is a delicately scaled, modular system of interconnected elements and suspended LED components. Dramatically powerful in its message of utility and simplicity,Suspenders®can be configured as individual lighting sculptures or as a tiered web of infinite scope and variety. Fixture is a composition of bar-mounted single cylinder glass diffuser luminaires. Features: • Includes mini box power feed with included mini box recessed transformer enclosure • 6'adjustable power cords/cables • Includes 6 bar-mounted cylinder luminaires and 2 bar-mounted light bars • Dimmable via electronic low voltage dimmers • Mini box transformer • Fixture covered by 1-year warranty,luminaires covered by 5-year warranty Note: Further configuration options are available upon request,please call(866)428-9289 to place custom order. If you have questions,call(866)428 9289 RECEIVED 04/06/2018 ASPEN BUILDING DEPARTMENT Catalog A L/THON/A LIGHTING y Num WATERS FIXTURE H Notes FEATURES&SPECIFICATIONS INTENDED USE Type Provides an LED lighting platform to deliver general ambient lighting for surface-mount ceiling applications.Light engine delivers long life and excellent color to ensure a quality,low-maintenance light installation.Ideal for use in closets,foyers,hallways,corridors,bedrooms,offices,utility work Decorative Indoor areas,and more. CONSTRUCTION LE D Wrap The LED wrap is constructed of a metal housing with decorative plastic end caps.The white acrylic diffuser provides even illumination and softens the appearance of the LEDs for improved aesthetics. OPTICS 2'wrap produces 1,200 lumens and 4'produces 2,380 lumens,both at 50,000 hours life. 1)114 Linear Flush Mount Thermal formed diffuser is of highly transmissive material to minimize lamp image and provides high- angle brightness control.One piece contemporary design wrap around diffuser soften appearance for improved aesthetics. LINEAR LED ELECTRICAL Long-life LEDs,coupled with a high-efficiency driver,provide extended service life.Standard input= ��� 20/40 watts(2'/4'),60 lumens perwatt.FMLWL is rated to deliver L70 performance at 50,000 hours.Fixture '`' operates at 120 volts,60Hz. LISTINGS UL certified to US and Canadian standards.Listed for damp locations.ENERGY STAR'certified. WARRANTY 5-year limited warranty.Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms and conditions.aspx NOTE:Actual performance may differ as a result of end-user environment and application. All values are design or typical values,measured under laboratory conditions at 25°C. Specifications subject to change without notice. Specifications 2' 4' Width: 5-1/2(14.0) 5-1/2(14.0) Length: 24-1/2(62.2) 47-2/5(120.4) Depth: 2-3/5(6.6) 2-3/5(6.6) Weight: 2.5 lbs(1.0 kg) 5.0 lbs(2.3 kg) All dimensions are inches(centimeters)unless otherwise indicated. ORDERING INFORMATION For shortest lead times,configure product using bolded options. Example:FMLWL 48 840 Series' CRI Color temperature FMLWL24 PLED wrap 8 >80 40 4000 K FMLWL48 4'LED wrap 35 3500K2 30 3000 K' 27 2700KZ Notes Accessories/Replacement parts 1 Usewithnun-dimmableswi he 2 Minimum 90-R ``��'�' orn &yV DFMLWL24 2'white acrylic diffuser temperatures 1,4 y. rc, DFMLWL48 4'white acrylic diffuser 3 Minimum 50-day lead time for non-stock color temperatures;mirO45 Or®an(i2 01 8 DECORATIVE INDOOR ASPENFMLWL BUILDING DEPARTMENT LED Linear Flush Mount PHOTOMETRICS FMLWL 24 840,1,200 delivered lumens,test no.LTL25857,tested in accordance to IESNA LM-79. 180° Coefficients of Utilization pf 20% 90° CP Summary pc 80% 70% 50% Zonal Lumen Summary 80° 0° 90 pw 70%50%30% 50%30%10% 50%30%10°% Zone Lumens %Lamp%Fixture 0° 455 455 0 119 119 119 116 116 116 111 111 111 0°-30° 344 28.4 28.4 10 5° 444 457 1 109104 99 101 98 94 97 94 91 0°-40° 554 45.8 45.8 15° 425 434 2 99 91 84 89 82 77 85 80 75 0°-60° 952 78.7 78.7 60° 20 25° 388 390 3 90 80 72 78 70 64 75 68 63 0°-90° 1202 99.3 99.3 35° 338 336 ,4 83 71 62 69 61 55 67 60 54 90°-120° 8 0.6 0.6 45° 278 272 05 76 63 54 62 54 47 60 52 47 90°-130° 8 0.7 0.7 30 55° 215 208 6 70 57 48 56 48 42 54 47 41 90°-150° 8 0.7 0.7 65° 146 142 7 65 52 43 51 43 37 49 42 36 90°-180° 8 0.7 0.7 40 40° 75° 77 80 8 61 47 39 47 39 33 45 38 33 0°-180° 1210 100.0 100.0 85° 16 29 9 57 43 35 43 35 30 42 34 29 0° 20° 90 1 14 10 53 40 32 40 32 27 39 32 27 - - 0° 90° FMLWL 48 840,2,383 delivered lumens,test no.LTL25859,tested in accordance to IESNA LM-79. 180° iIff W�1♦7• Coefficients of Utilization I%��� pf 20% IDS`1�MM, CP Summary pc 80% 70% 50% Zonal Lumen Summary 10r"`; �' 80° 0° 90 pw 70°%50%30% 50%30%10% 50%30%10% Zone Lumens %Lamp%Fixture l,,,�0� 0° 899 899 0 119 119 119 116 116 116 111 111 111 0'-30' 680 28.5 28.5 20r1, '�,',; 5° 884 901 1 109 104 100 101 98 94 97 94 91 0°-40° 1094 45.9 45.9 30.11111kNWA .60° 25° 775 768 2 99 91 84 89 82 77 85 80 75 0°-90° ° 1879 78.8 78.8 40t 25° 775 768 3 90 80 72 78 71 64 75 69 63 0°-90° 2370 99.5 99.5 50r�. �,. 35° 670 656 w 4 83 71 62 69 61 55 67 60 54 90°-120° 12 0.5 0.5 60r ,�.� 45° 550 534 6 76 63 54 62 54 47 60 53 471 90 -150 12 0.5 0.5 55° 419 407 6 70 57 48 56 48 42 54 47 41 90°-150° 12 0.5 0.5 70r 65° 286 280 7 65 52 43 51 43 37 49 42 37 90°-180° 12 0.5 0.5 40° 75° 155 157 8 61 47 39 47 39 33 45 38 33 0°-180 2383 100.0 100.0 80r� 90A���.�� 85° 34 59 9 57 44 35 43 35 30 42 35 30 20° 90 2 30 10 53 40 32 40 32 27 39 32 27 - - 0° 90° LIGHTING FACTS g iIghtrng facts lighting Ap,,1.ar°I....35 30E facts'5oL Light Output(Lumens) 1200 Light Output(Lumens) 2380 Watts 19.6 Watts 40 Lumens per Watt(Efficacy) 61 Lumens per Watt(Efficacy) 59 Color Accuracy Color Accuracy Color Rendering Index(CRP 85 Color Rendering Index(CRI) 85 Light Color 4000(Bright White) Light Color 4000(Bright White) . Id,M G,ro remx«a.ow GGrl 1M.rr-.Y:l n, H•n;1i1 LMI.I• !):ry''.,.,. Warm While Bright Whle Daylight 2700K 3000K 4500K 6500K 2700K 3000K 4500K 6500K Ad re.ur.are.ccooi g W IESNA L41.73200e Approve Method K,M.ElecfncS rvv All re.uu ate.c<onI g In IESAA L41.79.2000 App+oveo Method ro.rn.Ebcrnc.l end r+AolonMrk T.st.g of So6d44e4 L.)M.c The U.S D.pmen.nl Of Ens.gy(DOE)vaOn., Maomebk Testing of Sofd•Srw L{14.2 The U S D.pmenw,l of Energy(DOE)varl4s product tnl dela end mulls l Product let dale.M/Slue. Visit www.lightingfacta.com for the Label Reference Guide. Visit www.11ghtingfacta.com for the Label Reference Guide. Regeemwn Number NJSM•KO OGA(71141201.1 Room Numbs.NJSM.XV80FJ)71142014) Model Humber FMLWL 241M0 Model Hurler FMLWL 4e/L0 Type-Luminen.-Onmauve Type Lorne..•Decent. 1 t[JJ� i' �oI.ur , (A L/THON/A L/GNT/NG` 04/06/2018 An''4cuityBrands Company DECORATIVE INDOOR: One Lithonia Way Conyers,GA 30012 Phone:800.748.5070 Fax:770.860.3903 www.lithonia.com ©2014-2015 Acuity Brands Lighting,Inc.All rights reserved.Rev.° PEN BUILDING DEPARTMENT WATERS FIXTURE YLighting Cut Sheet Customize Information Print I Email Cut Sheet Change Your Info Upload Your Logo Printer Friendly Cut Sheet Change Client's Info Remove Your Logo Email Cut Sheet Price&Print Options PI cut sheet Mesh LED Pendant Light by Luceplan I YLighting https://www.ylighting.com/luceplan-mesh-led-pendant-light.html 1111111111111 Wattage: 65 �`� Lamp Type: led Listing: cUL UL Price: 4743.00 Dimensions: 31 Inch:31.5"D X 1, 23.6"H X 219"max overall height P • • 41 Material: steel polycarbonate I ID / 0 • ‘ • • t V • �► � ' • / ll '' - t :- — - Mesh LED Pendant Light by Luceplan I YLighting Company: Fixture Type: Pendant Lights Date: 03/18/2018 Room: Placement: Project: Approved By: Prepared By: [Edit][Clear] Prepared For: [Edit][Clear] RECEIVED 04/06/2018 ASPEN BUILDING DEPARTMENT WATERS FIXTURE J Click here to print this page CLIVING Coppelia Chandelier Item Code: MOI-COPPELIA-CHANDELIER Description: Material(s): Polycarbonate, Stainless-Steel Dimensions: • Small:24.7"D X 16.6"H • Large: 39.8"D X 21.3"H • Cable: 157"L Lamp Type: LED gig Bulbs: • Small: 36 X 20W(total)120V LED f/i modules,2700K,CRI 90,400 lumens (included) fp i • Large: 54 X 20W(total)120V LED f`' IIIL'1�)l A. modules,2700K,CRI 90,600 lumens ii• i11 (included) Zlii' r Listing:CUL, UL I I Fikt _ Manufacturer Information: Specifications 1 /�_--= Sheet 1,Specifications Sheet 2 _ . Price: Now: $2,180.25 Compare:$2,565.00 +Free Shipping Options: Model: Small Large The Coppelia Chandelier was designed by Arihiro Miyake in 2014. Inspired by the famous ballet of the same name,the Coppelia Chandelier embodies the grace and magic of a mechanical doll coming to life.The fluid and delicate movement of the ballerinas is captured through the frame and shades of this stunning fixture.Made from polished stainless steel and polycarbonate in a chromed finish,this elegant chandelier makes a beautiful addition to modern spaces. Offered in two sizes.A decorative statement piece that provides ambient illumination for modern dining rooms, living rooms,and entryways.Ships with transparent cord and cylindrical canopy in matching finish. If you have questions,call(866)428 9289 RECEIVED 04/06/2018 ASPEN BUILDING DEPARTMENT WATERS FIXTURE K YLighting Cut Sheet Customize Information Print I Email Cut Sheet Change Your Info Upload Your Logo Printer Friendly Cut Sheet Change Client's Info Remove Your Logo Email Cut Sheet Price&Print Options cut sheet Carbon 8 Foot LED Pendant Light by Tokio I YLighting https://www.yl ighti ng.com/tokio-carbon-carb 12-led-1 i near-penda nt- light.html Wattage: 6 Lamp Type: led Listing: cETL ETL Price: 7305.48 Dimensions: Overall: 96"L X 53"W;160" max H" Material: carbon-fiber Carbon 8 Foot LED Pendant Light by Tokio I YLighting Company: Fixture Type: Architectural Linear Suspension Date: 03/18/2018 Room: Placement: Project: Approved By: Prepared By: [Edit][Clear] Prepared For: [Edit][Clear] RECEIVED 04/06/2018 ASPEN BUILDING DEPARTMENT WATERS FIXTURE L YLighting Cut Sheet Customize Information Print I Email Cut Sheet Change Your Info Upload Your Logo Printer Friendly Cut Sheet Change Client's Info Remove Your Logo Email Cut Sheet Price&Print Options cut sheet Sideways 36 Inch Outdoor Led Wall Sconce by SONNEMAN I YLighting https://www.yl ig hti n g.com/son nema n-sideways-36-inch- outdoor-led-wall-sconce.html Wattage: 55 Lamp Type: led Listing: ADA wet-location Price: 690.00 Dimensions: Overall:3.25"W X 36.25"H X 3.25"extension Material: metal acrylic Sideways 36 Inch Outdoor Led Wall Sconce by SONNEMAN YLighting Company: Fixture Type: Outdoor Wall Lights Date: 03/18/2018 Room: Placement: Project: Approved By: Prepared By: [Edit][Clear] Prepared For: [Edit][Clear] RECEIVEt 04/06/2018 ASPEN BUILDING DEPARTMENT WATERS FIXTURE M YLighting Cut Sheet Customize Information Print I Email Cut Sheet Change Your Info Upload Your Logo Printer Friendly Cut Sheet Change Client's Info Remove Your Logo Email Cut Sheet Price&Print Options 11111 cut sheet Neo LED Flush Mount Ceiling Light by Modern Forms I YLighting https://www.yl ig hti ng.com/mod ern-forms-neo-led- flush-mou nt-cei l ing-lig ht.html Wattage: 25116.5148 Lamp Type: led Listing: ADA ETL cETL damp-location Price: 159.00 Dimensions: 8 Inch:8"W X 8"H;0.875" Extension Material: aluminum glass Neo LED Flush Mount Ceiling Light by Modern Forms I YLighting Company: Fixture Type: Flush Mount Ceiling Lights Date: 03/16/2018 Room: Placement: Project: 7 Approved By: Prepared By: [Edit][Clear] Prepared For: [Edit][Clear] RECEIVED 04/06/2018 ASPEN BUILDING DEPARTMENT WATERS FIXTURE N YLighting Cut Sheet Customize Information Print I Email Cut Sheet Change Your Info Upload Your Logo Printer Friendly Cut Sheet Change Client's Info Remove Your Logo Email Cut Sheet Price&Print Options Ali cut sheet Lumi-Mochi Wall Or Ceiling Light By Fabbian I YLighting • https://www.ylig hting.com/fabbian-lu m i-moch i-wall-ceil i ng- light.html Wattage: 251601150117 Lamp Type: halogen Listing: cETL ETL Price: 194.00 Dimensions: Extra Small:4.7"D X 4.3"H/Extension Material: blown-glass metal Lumi-Mochi Wall Or Ceiling Light By Fabbian I YLighting Company: Fixture Type: Flush Mount Ceiling Lights Date: 03/16/2018 Room: Placement: Project: 7 Approved By: Prepared By: [Edit][Clear] Prepared For: [Edit][Clear] RECEIVED 04/06/2018 ASPEN BUILDING DEPARTMENT WATERS FIXTURE 0 YLighting Cut Sheet Customize Information Print I Email Cut Sheet Change Your Info Upload Your Logo Printer Friendly Cut Sheet Change Client's Info Remove Your Logo Email Cut Sheet Price&Print Options / L �� • cut sheet .r Alias 15 Wall Sconce by Leucos I YLighting https://www.ylighting.com/leucos-alias-15-wall-sconce.html Wattage: 161100 Lamp Type: compact-fluorescent Listing: UL cUL IP20 Price: 595.00 Dimensions: 5.875"L X 4.75"W X 1.625"H Material: metal steel Alias 15 Wall Sconce by Leucos I YLighting Company: Fixture Type: Wall Sconces+Lights Date: 03/18/2018 Room: Placement: Project: Approved By: Prepared By: [Edit][Clear] Prepared For: [Edit][Clear] RECEIVEt 04/06/2018 ASPEN BUILDING DEPARTMENT Sundance Spas STATEMENT OF PRODUCT COMPLIANCE Model year: 2016,domestic(North America 60 Hz) Factory-Built Electric Hot Tub Products: 880 Series: MaxxusTM,AspenTM, OptimaTM, CameoTM, CapriTM, MajestaTA4,AltamarTM, MarinTM 780 Series: Hamilton TM ChelseeTM, CertaTM, Camden TM DoverTM, MontclairTM 680 Series: Hawthorne TM, HartfordTM, BurlingtonTM, DenaliTM,TacomaTM, Payton TM, Edison TM Select Series: ConstanceT"'Qictoria) The models listed above meet the following standards: • UL 1563(5th Edition)—Electric Spas, Equipment Assemblies and Associated Equipment • CanICSA-C22.2 No. 218.1-M89—Spas, Hot Tubs and Associated Equipment • FCC part 15 Subpart B Section 15.107& 15.109 • Virginia Graeme Baker Act—Sections 1401 — 1404 • ASME A112.19.8-2007-Suction Fittings for Use in Swimming Pools,Wading Pools, Spas, and Hot Tubs • ANSI Z124.7-97- Prefabricated Plastic Spa Shells/Uniform Swimming Pool, Spa and Hot Tub Code • ASTM F 1346-91 -Standard Performance Specification for Safety Covers and Labeling Requirements for All Covers for Swimming Pools, Spas and Hot Tubs • California Energy Commission 2007 Appliance Efficiency Regulations, California Code of Regulations, Title 20, Sections 1601-1608 • Products carry the following marks: ETL, USPC Laboratory Testing Performed at Sundance Spas, Inc.and by: Intertek Testing Services(ETL) IAPMO R&T CKC Laboratories Inc 25791 Commercentre Dr. 5001 East Philadelphia St. 5046 Sierra Pines Dr Lake Forest, CA 92630 Ontario, CA 91761 Mariposa, CA 95338 Person Maintaining Records of Compliance: Tony Sadati Sundance Spas, Inc. 14525 Monte Vista Avenue Chino, CA 91709 800-883-7727 www.sundancespas.com RECEIVED Updated 2-2-21:161/06/2018 ASPEN BUILDING DEPARTMENT TECHDATA Spa Cover = 2# density foam @ 25 degrees FOAM EPS - 2"-4" Taper has R=15 CONTROL - 3"-5" Taper has R=20 Foam-Control' EPS (expanded polystyrene) rigid board • ASTM C 578 (Thermal Insulation) foam plastic is for all types of industrial, packaging, and • ASTM E 2430 (EIFS boards) construction uses. Foam-Control EPS is manufactured in conformance with numerous standards. • ICC ES AC12 (Foam Plastic Insulation) Foam-Control EPS Properties ASTM C578 Property Type Type Type Type Type Type Type XI I VIII II IX XIV XV Nominal Density Ib/ft3 0.75 1.00 1.25 1.50 2.00 2.50 3.00 (kg/m3) (12) (16) (20) (24) (32) (40) (48) Density', min. lb/ft3 0.70 0.90 1.15 1.35 1.80 2.40 2.85 (kg/m3) (12) (15) (18) (22) (29) (38) (46) 25°F °F.ft2.h/Btu 3.6 4.4 4.6 4.8 5.0 5.0 5.1 (°K.m2/W) (0.63) (0.77) (0.80) (0.84) (0.88) (0.89) (0.90) Design Thermal - Resistance per 40°F °F.ft'.h/E3tu 3.4 4.2 4.3 4.6 4.8 4.8 4.9 (°K.m2/W) (0.60) (0.73) (0.75) (0.81) (0.84) (0.84) (0.85) 1.0 in. thickness 75°F °F.ft2.h/Btu 3.2 3.9 3.9 4.2 4.4 4.4 4.5 (°K.m2/W) (0.57) (0.68) (0.69) (0.73) (0.77) (0.77) (0.78) 25°F °F.ft2.h/Btu 3.5 4.2 4.4 4.6 4.8 4.8 4.9 (°K.m2/W) (0.61) (0.74) (0.77) (0.81) (0.84) (0.84) (0.86) Thermal Resistance', min per 40°F °F.ft2.h/Btu 3.3 4.0 4.2 4.4 4.6 4.6 4.7 (°K.m2/W) (0.58) (0.70) (0.74) (0.77) (0.81) (0.81) (0.83) 1.0 in. thickness 75°F °F.ft2.h/Btu 3.1 3.6 3.8 4.0 4.2 4.2 4.3 (°K.m2/W) (0.55) (0.63) (0.67) (0.70) (0.74) (0.74) (0.76) Compressive Strength' psi 5.0 10.0 13.0 15.0 25.0 40.0 60.0 ra 10% deformation, min. (kPa) (35) (69) (90) (104) (173) (276) (414) Flexural Strength', psi 10.0 25.0 30.0 35.0 50.0 60.0 75.0 min. (kPa) (69) (173) (208) (242) (345) (414) (517) Water Vapor Permeance' 5.0 5.0 3.5 3.5 2.5 2.5 2.5 of 1.0 in. thickness, max., perm Water Absorption' by total immersion, 4.0 4.0 3.0 3.0 2.0 2.0 2.0 max., volume % Foam-Control EPS has a flame spread index of 20 and a smoke developed index of 150-300 when tested in accordance with ASTM E84/UL 723 for densities from 0.7-3.6 Ib/ft'. Please refer to Foam-Control EPS UL certificates. ' See ASTM C578 Standard for test methods and complete information. RECEIVED WWW.FOAM-CONTROL.COM 04/06/2018 ASPEN BUILDING DEPARTMENT - rasping an outdated browser. More informatio » —4 C�!'i! 1'r ures Seating Specifications R�vFr�l'v�Ru pctr ENU PradoTM -680TM Series Prado TM - 680TM Series 4410, p (f �J 0 (J • 0 • • Find a Dealer Overview With room for up to five adults, the PradoTM spa offers a classic hydrotherapy experience with a plug and play option that is also easy to install with a standard household outlet. Perfect for small spaces or patios, the PradoTM spa offers seats with varying massage combinations that will surely leave you feeling renewed. Broad coverage back jets banish discomfort in large muscles. Unique to the 680TM Series, a pivot bench seat with targeted back relief fosters communication and makes it easy to move around. And, a textured foot well designed for tactile therapy houseS nNe Foot dome for full body relief. RECEIVED 04/06/2018 ASPEN BUILDING DEPARTMENT You are usir�q ar�outdated rowser. More info`mation » X ee roc ure Get Pricing Seats: 4-5 Size: 76" x 84" x 34.5" Lounge: No Price Range: $ $ $ $ Reviews (0):***** Color Options Whether you're charmed by soothing shades or bold hues, selecting the perfect color combination starts with a pleasing palette that blends seamlessly with your backyard decor. liiiiw \ . — 11 1 6 RECEIVED 04/06/2018 ASPEN BUILDING DEPARTMENT SHELL COLORS:_ PORCE•LAIN You are using an outdated browser. More information » X • • CABINET COLORS: COASTAL Ov Cameo° model shown for visualization purposes only. Tub size, configuration, features, controls, options, physical appearance and performance will vary by model. Not all colors available in all models. Cover Option Sundance° genuine vinyl and premium SunStrong°spa covers retain heat and help keep water cleaner while cover lifters make using your spa cover easy. Crafted specifically for your Sundance°spa, each marine- grade cover ensures a tight fit while adding a touch of style in palettes that coordinate with your shell and cabinetry. -4114; nStro g'• • - Imp ....4piminviimuminummin --41111. 4111111r Mirf- - /111 04/06/2018 ASPEN BUILDING DEPARTMENT mikizaimow You are using an ou.Fit.:.csis-1More information » X CLEARRAY® UV-C Technology + Filtration Treats water with the power of nature-inspired UV-C technology to neutralize waterborne pathogens, resulting in clean, fresh water. 680TM Filtration System with 50 square foot vertical filter, Dynamic FIowTM and CLEARRAY® system. Lighting and Waterfalls Standard lighting brightens up the interior and soothing waterfall adds ambiance. RECEIVED 04/06/2018 ASPEN BUILDING DEPARTMENT You are using an outdated browser. More information » X Seating PUP 1111/ Bench Seat A pivot bench seat with targeted back relief fosters communication and makes it easy to move around. 4POOF Comprehensive Back Seat Thispatio-sized hot tub offers a combination that delivers ample stress-meltingback RECEIVED jetp 04/06/2018 ASPEN BUILDING DEPARTMENT