Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.201 Clubside Dr.0004.2019 (2).ARBK
0004-2019-ARBK_BuildingComments_1 201 Clubside_Plans.pdf(8) m� Page:A102.2 SCALE: MIDDLE LEVEL FLOOR PLAN .. o -.,- 1 i� There are 2 dryers in the laundry PROPOSED if ii�i�.I�t', room. Provide makeup air if the 'I ®_- wawa* File Name: 201 Clubside_Plans.pdf _ _ -1 Subject: Dryer Makeup air total exhausted airflow exceeds MMI h Author: nickt 200cfm. (2015 IMC 504.6) BRED' Color: ■ Page:A102.2 SCALE: MIDDLE LEVEL FLOOR PLAN PROPOSED Indicate dryer vent duct length and termination location. 2015 1.4 —.- File Name: 201 Clubside_Plans.pdf l � �� Subject: PlanCheck IMC 504. H Author: nickt .m Color: ■ mow I E �—irr ETp7 0 r°i. Page:A102.2 SCALE: MIDDLE LEVEL FLOOR PLAN If the garage is not heated, the PROPOSED new wall between the b' File Name: 201 Clubside Plans.pdf Subject: PlanCheck mudroom/laundry and garage 1 illippl Author: nickt comply thermal envelope and �-=� must com I with the insulation Color: • and air sealing provisions of ;.. 'm�-Eh� © 2015 IECC R402. 9iimm Page:A103.2 UPPER LEVEL FLOOR PLAN PROPOSED O' File Name: 201 Clubside_Plans.pdf Ordinance 40, 2016 amended ""^"" "L . Subject: PlanCheck the 2015 IECC to require 0.28 U Author: nickt factor for fenestration. Revise. a III /E Color: • mil ,, Page:A201.1 EXTERIOR ELEVATIONS Ordinance 40, 2016 amended File Name: 201 Clubside_Plans.pdf °T.",7E.c the 2015 IECC to require 0.28 U u" - Subject: PlanCheck Author: nickt factor for fenestration. Revise. =owm - Color: ■ �o" T:1 I. „ Page:A401 ENLARGED STAIR PLAN &SECTIONS Handrail ends must return to a File Name: 201 Clubside_Plans.pdf C ' l " wall, guard, newel post, or floor :_ - Subject: handrail returns- surface. 2015 IRC R311.7.8.2. Fa 1 - Author: nickt Color: ■ .k — Jl Page:A501 DETAILS File Name: 201 Clubside_Plans.pdf Indicate air sealing with notes. (Ordinance 40, 2016) Subject: PlanCheck 4111166 � Author: nickt " �� Color: ■ ti ilt •/I ;,; Page:A501 DETAILS File Name: 201 Clubside_Plans.pdf Glass guards must comply with Subject: PlanCheck one of the following: Have a top e ,,a-,p ® ,,,,,a-,.o Author: nickt cap supported by at least 3 vy Color: ■ panes of glass; have a top cap m�.a ,g.op„ �,. mp," supported independent of the glass; or in the case of no top . �" o7 I�III�I' �l cap, be at least two plies of g= "Po""7" Ild equal thickness glass laminated _.n.. e ' _...._IIIIII'_ together. Provide details demonstrating compliance with one of the above as well as method of attachment and support. Must support a point load of 2001bs. Please note that many glass support manufacturers require a top cap; if you exceed their design you will need a stamped engineered design. (Ordinance 40, 2016)