HomeMy WebLinkAboutFile Documents.121 E Hyman Ave.0008-2019-BCHO (2) 0008-2019-BCHO_BuildingComments_1
5_121 E Hyman Architectural Drawings.pdf(2)
AA _ 4„,:_ ,..:,. Subject: PlanCheck The built-in bench creates a
Page Label: ISTING&PROPOSED ROOF PLAN
Page Index: 7 walking surface beside the
4W Author: tonyf guardrail, so the guardrail must
° Color: • extend 36"above the surface of
• File Name: 5_121 E Hyman Architectural Drawings.pdf the bench, per COA policy.
Please revise this detail at all
"'�"' MA: As discussed with Tony Fusaro, we have added
I � built-in benches.
a bench back that extends at least 36" above the surface
of the bench seat. See Revision 7 Delta and cloud and
--— .ry Sheets A-108, A-109, A-205, A-304 and Detail 5/A-507.4
_ Subject: PlanCheck
° � Page Label: TERIOR ELEVATIONS Wall cap serving as guard rail
Page Index: 10 must extend 36"above surface
Author: tonyf of built-in benches and side table
*muColor: ■ per COA policy.Typical. Please
File Name: 5_121 E Hyman Architectural Drawings.pdf revise.
— MA: As discussed with Tony Fusaro, we have added
a bench back that extends at least 36" above the surface
of the bench seat. See Revision 7 Delta and cloud and
Sheets A-108, A-109, A-205, A-304 and Detail 5/A-507.4
8_121 E Hyman Lighting Drawings.pdf(1)
Subject: PlanCheck o
Page Label: [1] LT 1.0 A minimum of 75/o of all lamps
Page Index: 1 installed in permanent fixtures
Author: tonyf
must be high efficiency in
^ ' Color: ■ dwelling
lC i1" +,r a units. Note this requirement on
��,• File Name: 8_121 E Hyman Lighting Drawings.pdf the
I it, plans. (2015 IECC R404.1 &
MA: See note on upper right hand side of Sheet LT-1.0 C405.1)
We have changed the stair to the Roof Deck. See attached Sheets A-406 and 1-202 from Rowland and Broughton.
RFCE VED
06/15/2020
ASPEN