Loading...
HomeMy WebLinkAboutFile Documents.121 E Hyman Ave.0008-2019-BCHO (2) 0008-2019-BCHO_BuildingComments_1 5_121 E Hyman Architectural Drawings.pdf(2) AA _ 4„,:_ ,..:,. Subject: PlanCheck The built-in bench creates a Page Label: ISTING&PROPOSED ROOF PLAN Page Index: 7 walking surface beside the 4W Author: tonyf guardrail, so the guardrail must ° Color: • extend 36"above the surface of • File Name: 5_121 E Hyman Architectural Drawings.pdf the bench, per COA policy. Please revise this detail at all "'�"' MA: As discussed with Tony Fusaro, we have added I � built-in benches. a bench back that extends at least 36" above the surface of the bench seat. See Revision 7 Delta and cloud and --— .ry Sheets A-108, A-109, A-205, A-304 and Detail 5/A-507.4 _ Subject: PlanCheck ° � Page Label: TERIOR ELEVATIONS Wall cap serving as guard rail Page Index: 10 must extend 36"above surface Author: tonyf of built-in benches and side table *muColor: ■ per COA policy.Typical. Please File Name: 5_121 E Hyman Architectural Drawings.pdf revise. — MA: As discussed with Tony Fusaro, we have added a bench back that extends at least 36" above the surface of the bench seat. See Revision 7 Delta and cloud and Sheets A-108, A-109, A-205, A-304 and Detail 5/A-507.4 8_121 E Hyman Lighting Drawings.pdf(1) Subject: PlanCheck o Page Label: [1] LT 1.0 A minimum of 75/o of all lamps Page Index: 1 installed in permanent fixtures Author: tonyf must be high efficiency in ^ ' Color: ■ dwelling lC i1" +,r a units. Note this requirement on ��,• File Name: 8_121 E Hyman Lighting Drawings.pdf the I it, plans. (2015 IECC R404.1 & MA: See note on upper right hand side of Sheet LT-1.0 C405.1) We have changed the stair to the Roof Deck. See attached Sheets A-406 and 1-202 from Rowland and Broughton. RFCE VED 06/15/2020 ASPEN BUILDING DEPARTMENT