Loading...
HomeMy WebLinkAboutFile Documents.905 Chatfield Rd.0085.2019 (30).ARBK pThe Association of Pool&Spa Professionals® Print Save As PDF ANSI/APSP/ICC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS PROJECT NAME: 905 Chatfield CONTRACTOR NAME GF Woods Construction AND ADDRESS AND ADDRESS: Aspen, CO 81611 PO BOX 12283 Aspen, CO 81612 OWNER:Silverstein CONTRACTOR PHONE:(970)948-6483 DATE:7/19/2019 This information sheet was prepared by the APSP-15 Residential Swimming Pool and Spa Energy Efficiency Standard Writing Committee of the Association of Pool and Spa Professionals(APSP). It is not part of the American National Standard ANSI/APSP/ICC-15 2011 but is included for information only.Contractors should acquire and comply with the ANSI/APSP/ICC-15 2011 standard which can be purchased at www.apsp.org. 1. §5.2.1:Calculated pool volume a. Gallons: 1,141 or 1. 1,141 gallons b.Calculated Gallons: (surface area)X (average depth)X 7.48 (gal/ft^3) = 0 2.§5.2.1:Calculated maximum filtration flow rate 2. 36 gpm (Pool volume-360 or 36gpm whichever is larger) 3.§5.2.2:Auxiliary Pool Load: ❑ Yes, ❑ No? (Enter the highest"auxiliary pool load"to be powered by the swimming pool filtration pump.Do not add auxiliary 3. 60 gpm pool load flow rates together,only the highest is used.) 4. Calculated maximum flow rate 4. 60 gpm (Item 2 or item 3, whichever is larger.) 5.§5.5.1: Pipe sizing: a. Minimum suction pipe diameter 5a. 2.0 inches (Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the same or more than item 4.) b. Minimum suction branch pipe diameter 5b. 2.0 inches (Calculate:Item 4. 60 (gpm)_Branch Pipes 1 (quantity)=branch flow rate 60 (gpm). Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the same or more than the calculated suction branch flow rate.) c. Minimum return pipe diameter 5c. 2.0 inches (Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the same or more than item 4.) d. Minimum return branch pipe diameter 5d. 2.0 inches (Calculate:Item 4. 60 (gpm)_Branch Pipes 1 (quantity)=branch flow rate 60 (gpm). Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the same or more than the calculated return branch flow rate.) 6.§5.4.1: Filter type and size: a. Filter type: (Cartridge, DE,Sand) 6a. Cartridge b. Minimum filter area 6b. 160.0 sq.ft. - (Calculate:item 4. 60 (gpm)_filter factor 0.375 ) Filter factors:Cartridge=0.375, Sand=15,Diatomaceous Earth=2 7. §5.4.2: Backwash valve: ❑Yes, ❑No? 7. 2.0 inches - (When using a backwash valve,enter result of item 5c or 2 inches whichever is larger) Table 1 Pipe Size: 1.5" 2" 2.5" 3" 3.5" 4" 5" 6" Nominal GPM @ 6 fps 38 63 90 138 185 238 374 540 Nominal GPM @ 8 fps 51 84 119 184 247 317 499 720 8.Pump selection: §5.3.2.1:Pools 17,000 gallons or less,select pump*from the database with a Curve-A gpm flow equal to item 2 or less. §5.3.2.2:Pools 17,001 gallons or more,select pump*from the database with a Curve-C gpm flow equal to item 2 or less. *Multi- speed pumps must have one speed listed that satisfies this requirement. a. Pump model 8a. Pentair Intelliflo VF b.Pump flow 8b. 60 gpm (§5.3.2.1,5.3.2.2:Applicable Curve A or C gpm flow listed in database) 4/4/12 ANSI/APSP/ICC-15 Standard Writing Committee Form 1 of 2 ANSI/APSP/ICC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS Component / Section Requirements Check 4.4.1.1 Heater has no pilot light ✓ 4.4.1.2 Readily accessible on-off switch mounted outside of the heater ✓ Heaters No electric resistance heating unless for inground spa with tight fitting cover with R-6 insulation, 4.3.1.3 lieor for pool with 60%of documented pool heating from on-site solar or recovered energy. 4.3.2 Heater efficiency:gas/oil fired heater efficiency at least 78%, heat pump COP at least 4.0 ✓ 5.1.1 Pool filter pump listed in database ✓ 5.3.1 Pool filter pump with total horsepower 1.0 or more is multi-speed ✓ Multi-speed pump controller programmed to default to the filtration flow rate when no auxiliary 5.3.3 pool loads are operating within 24 hours and programmed with temporary override capability for ✓ servicing. Pool systems 5.3.4 Single-speed pump controller capable of operating pump during off-peak electric demand. 5.5.2 Pipe before pump has at least 4 diameters of straight pipe. ✓ System installed with solar,or setup for the future addition of solar heating equipment by 5.5.3 installing 18 inches of horizontal or vertical pipe after the filter and before a heater,or built-in or ri built-up connections, or dedicated pipe to and from the pool. 5.5.6 Directional inlets for mixing pool water. ✓ 4/4/12 ANSI/APSP/ICC-15 Standard Writing Committee Form 2 of 2