HomeMy WebLinkAboutFile Documents.121 E Hyman Ave.0149.2018 (91).ARBK irREScheck Software Version 4.6.5 Compliance Certificate Project Cayton Residence Energy Code: 2015 IECC Location: Aspen, Colorado Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 3,853 ft2 Glazing Area 22% Climate Zone: 7 (9922 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 121 E Hyman Ave Luis Menendez Dan Findley Aspen, CO 81611 Menendez Architects AEC 715 W Main St, Suite 104 40801 US-6 Aspen, CO 81611 Avon, CO 81620 970-748-8520 Compliance: Passes using UA trade-off Compliance: 2.9%Better Than Code Maximum UA: 657 Your UA: 638 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter North Wall: Wood Frame, 16" o.c. 272 35.6 0.0 0.045 9 W-C: Metal Frame with Thermal Break:Double Pane with Low-E 22 0.320 7 W-D: Metal Frame with Thermal Break:Double Pane with Low-E 16 0.320 5 W-E: Metal Frame with Thermal Break:Double Pane with Low-E 40 0.290 12 East Wall: Wood Frame, 16" o.c. 660 35.6 0.0 0.045 25 W-O: Metal Frame with Thermal Break:Double Pane with Low-E 6 0.320 2 reviewsW-P: Metal Frame with Thermal Break:Double Pane with Low-E .90 6 W-Q: Metal Frame with Thermal Break:Double Pane with Low-E D:20 2 W-R: Metal Frame with Thermal Break:Double Pane with Low-E 6/1 8/21 320 5 W-U: Metal Frame with Thermal Break:Double Pane with Low-E 20p ,out cumi rune011�0.320 6 W-V: Metal Frame with Thermal Break:Double Pane with Low-E 20 RIC �•� 0.320 6 W-W: Metal Frame with Thermal Break:Double Pane with Low-E 17 0.320 5 W-A.1.A: Metal Frame with Thermal Break:Double Pane with Low-E 6 0.320 2 Nort east : Wood Frame, 0. 45 9 W AhMetal Framel with Thermal Break:Double "B eak:Double Pane with Low EIVED358 35.6 0.0 0.3320 19 W-B: Metal Frame with Thermal Break:Double Pane with Low-E 06/18/2021 53 0.320 17 Project Title: Cayton Residence ASPEN Report date: 06/15/21 Data filename: R:\_2017\17083.00 - Cayton Residence\41CF.tici It 9t5ml M iNal\17083 CAYTON - 2021- Page 1 of 2 0515.rck Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter W-A.1.B: Metal Frame with Thermal Break:Double Pane with Low-E 41 0.260 11 Northwest: Wood Frame, 16" o.c. 120 35.6 0.0 0.045 5 South Wall: Wood Frame, 16" o.c. 450 35.6 0.0 0.045 12 W-M: Metal Frame with Thermal Break:Double Pane with Low-E 21 0.320 7 W-N: Metal Frame with Thermal Break:Double Pane with Low-E 47 0.340 16 Garage Door: Glass 115 0.550 63 West Wall: Wood Frame, 16" o.c. 952 35.6 0.0 0.045 38 W-F: Metal Frame with Thermal Break:Double Pane with Low-E 21 0.320 7 W-G: Metal Frame with Thermal Break:Double Pane with Low-E 21 0.320 7 W-H: Metal Frame with Thermal Break:Double Pane with Low-E 6 0.320 2 W-I: Metal Frame with Thermal Break:Double Pane with Low-E 6 0.320 2 W-J: Metal Frame with Thermal Break:Double Pane with Low-E 16 0.300 5 W-K: Metal Frame with Thermal Break:Double Pane with Low-E 13 0.320 4 W-L: Metal Frame with Thermal Break:Double Pane with Low-E 20 0.290 6 W-A.1.C: Metal Frame with Thermal Break:Double Pane with Low-E 6 0.320 2 Flat Roof: Flat Ceiling or Scissor Truss 101-- g665 61.0 13.0 0.018 11 Skylight 1: Metal Frame with Thermal Break:Single Pa .....) 27 0.550 15 Skylight 2: Metal Frame with Thermal Break:Single Pa - 6/18/21 awe) 16 0.550 9 Skylight 3: Metal Frame with Thermal Break:Single Pane 16 0.550 9 SMUAUCOMMANCE Skylight 4: Metal Frame with Thermal Break:Single Pane RIC 16 0.550 9 Cathedral Roof: Cathedral Ceiling 547 51.0 13.0 0.016 9 Roof under patio &driveway: Flat Ceiling or Scissor Truss 1,189 51.0 13.0 0.019 23 Basement Wall 1: Solid Concrete or Masonry 1,854 13.0 10.0 0.033 61 Wall height: 9.0' Depth below grade: 9.0' Insulation depth: 9.0' RECEIVED Floor 1: Slab-On-Grade:Heated 242 10.0 0.684 166 Insulation depth: 6.0' 06/18/2021 Crawl 1: Solid Concrete or Masonry 105 0.0 16.0 0.052 2 Wall height: 5.5' Depth below grade: 5.5' ASPEN Insulation depth: 5.5' BUILDING DEPARTMENT Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Taylor Critchlow -- 6/15/21 Name-Title Signature Date Project Title: Cayton Residence Report date: 06/15/21 Data filename: R:\_2017\17083.00 - Cayton Residence\Calculations\Mechanical\17083 CAYTON - 2021- Page 2 of 2 0515.rck