HomeMy WebLinkAboutFile Documents.121 E Hyman Ave.0149.2018 (91).ARBK irREScheck Software Version 4.6.5
Compliance Certificate
Project Cayton Residence
Energy Code: 2015 IECC
Location: Aspen, Colorado
Construction Type: Single-family
Project Type: New Construction
Conditioned Floor Area: 3,853 ft2
Glazing Area 22%
Climate Zone: 7 (9922 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
121 E Hyman Ave Luis Menendez Dan Findley
Aspen, CO 81611 Menendez Architects AEC
715 W Main St, Suite 104 40801 US-6
Aspen, CO 81611 Avon, CO 81620
970-748-8520
Compliance: Passes using UA trade-off
Compliance: 2.9%Better Than Code Maximum UA: 657 Your UA: 638
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
North Wall: Wood Frame, 16" o.c. 272 35.6 0.0 0.045 9
W-C: Metal Frame with Thermal Break:Double Pane with Low-E 22 0.320 7
W-D: Metal Frame with Thermal Break:Double Pane with Low-E 16 0.320 5
W-E: Metal Frame with Thermal Break:Double Pane with Low-E 40 0.290 12
East Wall: Wood Frame, 16" o.c. 660 35.6 0.0 0.045 25
W-O: Metal Frame with Thermal Break:Double Pane with Low-E 6 0.320 2
reviewsW-P: Metal Frame with Thermal Break:Double Pane with Low-E .90 6
W-Q: Metal Frame with Thermal Break:Double Pane with Low-E D:20 2
W-R: Metal Frame with Thermal Break:Double Pane with Low-E 6/1 8/21 320 5
W-U: Metal Frame with Thermal Break:Double Pane with Low-E 20p ,out cumi rune011�0.320 6
W-V: Metal Frame with Thermal Break:Double Pane with Low-E 20 RIC �•� 0.320 6
W-W: Metal Frame with Thermal Break:Double Pane with Low-E 17 0.320 5
W-A.1.A: Metal Frame with Thermal Break:Double Pane with Low-E 6 0.320 2
Nort
east
: Wood Frame,
0.
45 9
W AhMetal Framel with Thermal Break:Double "B eak:Double Pane with Low EIVED358 35.6 0.0 0.3320 19
W-B: Metal Frame with Thermal Break:Double Pane with Low-E 06/18/2021 53 0.320 17
Project Title: Cayton Residence ASPEN Report date: 06/15/21
Data filename: R:\_2017\17083.00 - Cayton Residence\41CF.tici It 9t5ml M iNal\17083 CAYTON - 2021- Page 1 of 2
0515.rck
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
W-A.1.B: Metal Frame with Thermal Break:Double Pane with Low-E 41 0.260 11
Northwest: Wood Frame, 16" o.c. 120 35.6 0.0 0.045 5
South Wall: Wood Frame, 16" o.c. 450 35.6 0.0 0.045 12
W-M: Metal Frame with Thermal Break:Double Pane with Low-E 21 0.320 7
W-N: Metal Frame with Thermal Break:Double Pane with Low-E 47 0.340 16
Garage Door: Glass 115 0.550 63
West Wall: Wood Frame, 16" o.c. 952 35.6 0.0 0.045 38
W-F: Metal Frame with Thermal Break:Double Pane with Low-E 21 0.320 7
W-G: Metal Frame with Thermal Break:Double Pane with Low-E 21 0.320 7
W-H: Metal Frame with Thermal Break:Double Pane with Low-E 6 0.320 2
W-I: Metal Frame with Thermal Break:Double Pane with Low-E 6 0.320 2
W-J: Metal Frame with Thermal Break:Double Pane with Low-E 16 0.300 5
W-K: Metal Frame with Thermal Break:Double Pane with Low-E 13 0.320 4
W-L: Metal Frame with Thermal Break:Double Pane with Low-E 20 0.290 6
W-A.1.C: Metal Frame with Thermal Break:Double Pane with Low-E 6 0.320 2
Flat Roof: Flat Ceiling or Scissor Truss 101--
g665 61.0 13.0 0.018 11
Skylight 1: Metal Frame with Thermal Break:Single Pa .....) 27 0.550 15
Skylight 2: Metal Frame with Thermal Break:Single Pa - 6/18/21 awe) 16 0.550 9
Skylight 3: Metal Frame with Thermal Break:Single Pane 16 0.550 9
SMUAUCOMMANCE
Skylight 4: Metal Frame with Thermal Break:Single Pane RIC 16 0.550 9
Cathedral Roof: Cathedral Ceiling 547 51.0 13.0 0.016 9
Roof under patio &driveway: Flat Ceiling or Scissor Truss 1,189 51.0 13.0 0.019 23
Basement Wall 1: Solid Concrete or Masonry 1,854 13.0 10.0 0.033 61
Wall height: 9.0'
Depth below grade: 9.0'
Insulation depth: 9.0' RECEIVED
Floor 1: Slab-On-Grade:Heated 242 10.0 0.684 166
Insulation depth: 6.0' 06/18/2021
Crawl 1: Solid Concrete or Masonry 105 0.0 16.0 0.052 2
Wall height: 5.5'
Depth below grade: 5.5' ASPEN
Insulation depth: 5.5' BUILDING DEPARTMENT
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Taylor Critchlow -- 6/15/21
Name-Title Signature Date
Project Title: Cayton Residence Report date: 06/15/21
Data filename: R:\_2017\17083.00 - Cayton Residence\Calculations\Mechanical\17083 CAYTON - 2021- Page 2 of 2
0515.rck