Asbestos Sampling Report Client Job Name
Date:06/25/2018 Snow Condos
Date of Inspection: 06/22/2018
Client: Property Address
HS Built 926 Waters Ave.
Chris Hendrickson Aspen, CO 81611
130 Primrose Path
Aspen, CO 81611
Attn: TABLE OF CONTENTS
Ben Feirstien 1.0 -Scope of Work
2.0 -Sampling Requirements
3.0 -Sampling Methodology
4.0 - Laboratory
Building Inspector: 5.0 -Suspect Materials Sampled
Ellen Johnson 6.0 -Table of Results
7.0 - Description of Sampling Area
CDPHE#23799 8.0 -Conclusion
- Lab Report
Joshua Johnson - Certifications
CDPHE#18401 Asbestos Samples Analyzed: 8
Positive Asbestos Samples: 0
RECEIVED
ELEMENT ENVIRONMENTAL I HendriclagAgsYitiw
ASPEN
BUILDING DEPARTMENT
Pr
1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel.
Element Environmental conducted a visible inspection for visible materials that would
be impacted during the remodel. This inspection was limited to the areas found in the
Description of the Sampling Area 7.0. Although sampling is destructive in nature, this
was a non-invasive inspection. It was of materials that were accessible. If other suspect
materials become visible/apparent during demolition or construction activities, work in
that area should be halted and more sampling/testing must take place, per Colorado
regulations. Any suspect materials that were not tested are to be assumed to contain
asbestos.
2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with
Colorado State Requirements. The minimum number of samples per homogenous areas
are as follows:
2.1- Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples
1,000 sq.ft.- 5,000sq.ft.- Minimum of 5 samples
>5,000 sq.ft. Minimum of 7 samples
2.2- Miscellaneous materials- Minimum of 2 samples
2.3-Thermal Systems Insulation (TSI)- Minimum of 3 samples
3.0- The purpose of the inspection is to identify materials that are homogenous. A
homogeneous area is defined as one which shares suspect material, texture, color,
location, and/or apparent time of construction. The materials are segregated into
separate homogenous areas. The size is determined and then samples are taken. The
materials are touched to determine friability. Friable ACM is material that can be
crushed or reduced to powder by hand pressure. The samples are taken in a random
numerical sequence.
4.0- Ellen Johnson, a Colorado Department of Public Health & Environment certified building
inspector, certification number: 23799, performed the inspection. The findings were
reviewed by Josh Johnson, a Colorado Department of Public Health & Environment
certified building inspector, certification number: 18401. Samples taken were sent to
CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light
Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be
trace, or<1% asbestos, is considered to be ACM material. This material would still be a
regulated material by CDPHE. The sample must have an additional "point count"
performed to be considered less than 1% and not be regulated by the CDPHE. The lab's
documents with analyses and findings are found below.
RECEIVED
ELEMENT ENVIRONMENTAL I Hendric1§14ACZ iirfAw
ASPEN
BUILDING DEPARTMENT
111117
5.0- SUSPECT MATERIALS SAMPLED
• Drywall
• Joint Compound
• Tape
• Texture
• Roofing Material
• Exterior Stucco
6.0- TABLE OF RESULTS
HOMOGENOUS AREA DESCRIPTION OF ACM CATEGORY NUMBER OF APPROXIMATE ACM %AND TYPE OF ASBESTOS
AREA SAMPLES SQ.FT.* ASSESSMENT FOUND
CATEGORIES
(A) Light Roll Texture in Surfacing 3 —600 sq.ft. N/A No Asbestos Detected
Unit 202
(B) Roofing Sealer Miscellaneous 2 "200sq.ft. N/A No Asbestos Detected
(C) Exterior Stucco Surfacing 3 —900 sq.ft N/A No Asbestos Detected
Key:
ACM Assessment Categories:
1-Damaged or significantly damaged Thermal Systems Insulation 6-ACM with potential for significant damage
(TSI)ACM 7-Friable ACM with low potential for damage
2-Damaged friable Surfacing ACM Other-ACM not classified in the above Assessment Categories
3-Significantly damaged friable Surfacing ACM N/A-Not Applicable
4-Damaged or significantly damaged friable Miscellaneous ACM
5-ACM with potential for damage *Square footage is estimated and not for bidding purposes
7.0- DESCRIPTION OF SAMPLING AREA
• The Light Roll Texture in the Living Room of Unit 202
• The Roof Sealing Material
• The Exterior Stucco
RECEIVED
ELEMENT ENVIRONMENTAL I Hendriclag8'2gtgw
ASPEN
BUILDING DEPARTMENT
CONCLUSION
No asbestos was detected in any of the samples. Feel free to contact us with any
questions.
Ellen Johnson,
e e rn e n t 189 county rd 135 glenwood springs, co 81601 970.274.3139
www.elementconsults.com
ENVIRONMENTAL INC
LEAD ASBESTOS HAZMAT REMED
ELEMENT ENVIRONMENTAL I Hendrick t 2iL'1+8sr w
ASPEN
BUILDING DEPARTMENT
ASBESTOS BULK ANALYSIS
tiff eu rof i n s By: POLARIZING LIGHT MICROSCOPY
CEI
Client: Element Environmental LLC Lab Code: A18-6558
189 CR 135 Date Received: 06-25-18
Glenwood Springs, CO 81601 Date Analyzed: 06-25-18
Date Reported: 06-25-18
Project: HSB 062218 Snow;926 Waters
ASBESTOS BULK PLM, EPA 600 METHOD
Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS
Lab ID Description Attributes Fibrous Non-Fibrous
926 Al Drywall Heterogeneous 15% Cellulose 85% Gypsum None Detected
Layer 1 White
A37240 Fibrous
Bound
Layer 2 Mud Heterogeneous 2% Cellulose 8% Paint None Detected
A37240 Cream 90% Calc Carb
Fibrous
Bound
926 A2 Mud Heterogeneous 2% Cellulose 8% Paint None Detected
A37241 Cream 90% Calc Carb
Fibrous
Bound
Lab Notes:No Drywall present in the sample.
926 A3 Drywall Heterogeneous 15% Cellulose 85% Gypsum None Detected
Layer 1 White
A37242 Fibrous
Bound
Layer 2 Mud Heterogeneous 2% Cellulose 8% Paint None Detected
A37242 Cream 90% Calc Carb
Fibrous
Bound
926 B1 Roof Sealer Homogeneous 2% Cellulose 98% Binder None Detected
Layer 1 White
A37243 Fibrous
Bound
Layer 2 Roof Sealer Homogeneous 2% Cellulose 98% Binder None Detected
A37243 Gray
Fibrous
Bound
Page 1 of 3
RECEIVED
ELEMENT ENVIRONMENTAL I Hendricln4t 2CZMw
ASPEN
BUILDING DEPARTMENT
6
ASBESTOS BULK ANALYSIS
tiff eu rof i n s By: POLARIZING LIGHT MICROSCOPY
CEI
Client: Element Environmental LLC Lab Code: A18-6558
189 CR 135 Date Received: 06-25-18
Glenwood Springs, CO 81601 Date Analyzed: 06-25-18
Date Reported: 06-25-18
Project: HSB 062218 Snow;926 Waters
ASBESTOS BULK PLM, EPA 600 METHOD
Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS
Lab ID Description Attributes Fibrous Non-Fibrous % J
926 B2 Roof Sealer Homogeneous 2% Cellulose 98% Binder None Detected
A37244 White
Fibrous
Bound
926 Cl Stucco Heterogeneous 2% Cellulose 3% Paint None Detected
A37245 Cream/Gray 60% Binder
Fibrous 35% Silicates
Bound
926 C2 Stucco Heterogeneous 2% Cellulose 3% Paint None Detected
A37246 Cream/Gray 60% Binder
Fibrous 35% Silicates
Bound
926 C3 Stucco Heterogeneous 2% Cellulose 3% Paint None Detected
A37247 Cream/Gray 60% Binder
Fibrous 35% Silicates
Bound
Page 2 of 3
RECEIVED
ELEMENT ENVIRONMENTAL I Hendric1§1401Z8r w
ASPEN
BUILDING DEPARTMENT
tiff eurofins
CEI
LEGEND: Non-Anth = Non-Asbestiform Anthophyllite
Non-Trem = Non-Asbestiform Tremolite
Calc Carb =Calcium Carbonate
METHOD: EPA 600/R93/116 and EPA 600/M4-82/020
REPORTING LIMIT: <1%by visual estimation
REPORTING LIMIT FOR POINT COUNTS:0.25%by 400 Points or 0.1%by 1,000 Points
REGULATORY LIMIT: >1%by weight
Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as
vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that
all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission
Electron Microscopy(TEM). Please note that PLM analysis of dust and soil samples for asbestos is not
covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.
This report relates only to the samples tested or analyzed and may not be reproduced, except in full,
without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the
accuracy of client submitted information in preparing and presenting analytical results. Interpretation of
the analytical results is the sole responsibility of the client. Samples were received in acceptable
condition unless otherwise noted. This report may not be used by the client to claim product
endorsement by NVLAP or any other agency of the U.S. Government.
•
ANALYST: 5 APPROVED BY: lerw✓.Yto
adekar Tianbao Bai,Ph.D.,CIH
Laboratory Director
NVLA
TESTING
NVLAP LAB CODE 101768-0
Page 3 of 3
RECEIVED
ELEMENT ENVIRONMENTAL I Hendric1§14A01Z kfAw
ASPEN
BUILDING DEPARTMENT
8
f', f. 1` r ' I' f
r
'tea 1:: "1"•' ,
't
f
Colorado Department - Colorado Department
of Public Health �f Public Heats
and Environment - and Environment
‘.- ASBESTOS ASBESTOS
CERTIFICATION* •` - i CERTIFICATION* •
't This certifies that -1
�.,' This certifies that
-"..
-
• t Joshua Jay Johnson t t Ellen Johnson 1
Certification No.:18401 Certification No.:2J799 N•
I has met the requirements of 25-7-507,C.R.S.and Air Quality Control /
has met the requirements of 25-7-507,C.R.S.and Air Quality Control t .._. Commission Regulation No.8,Part B,and is hereby certified by the
Commission Regulation No.8,Part B,end is hereby certified by the / state of Colorado in the following discipline:
state of Colorado in the following discipline: y -
- f r` - Building Inspector*
Building Inspector*
`, Issued: Jul)19,2017
Issued: July 14,20I7 ,i'f Expires: July 19,2018
Expires: July 14,2018
! A ,,. niP.,,i„n .i Yz!GG/. � ). a't n4+�4. wnM .M NY/{L i[ZLI.. J 1,
' na:`s,... Ino'^rw^' (, Mw ssN
etK �
i .. a s r
Y y`
}c 4 t
its ..,; , .,'Fa^f. 4sv*1 S Et fi CIm s t!1 iTe+ f rAial;a-3 r
4ot.� a-7
f876 +
Colorado Department E.
of Public Health
and Environment y
ki
` ASBESTOS CONSULTING FIRM 4
This certifies that 5
Element Environmental LLC t`
Registration No.:ACF-21640 Dr
has met the registration requirements of 25-7-507,C.R.S.and the Air Quality Control `
Commission Regulation No.8,Part B,and is hereby authorized to perform asbestos consulting -
activities as required under Regulation No 8,Part B,in the state of Colorado. r a
r .V:
Issued: January 08,2018 / -` f'
Expires: January 07,2019 -. _._= //JI% ' '/ JIB
se E.
..�. .. a. t..
RECEIVED
ELEMENT ENVIRONMENTAL I Hendrick t iL'1BSr w
ASPEN
BUILDING DEPARTMENT