HomeMy WebLinkAboutFile Documents.735 Castle Creek Dr.0196.2018 (19).ARBK DATE:7/25/2018MASTER PERMIT: PERMIT NUMBER:0196.2018.ARBK PERMIT NUMBER:
COMMUNITY DEVELOPMENT DEPARTMENTilli COMMUNITY DEVELOPMENT DEPARTMENT * Field Plan Set Must Be Printed In Color „
BUILDING PERMIT APPLICATION BUILDING DESCRIPTION FORM-IRC&IBC
PROPERTY INFORMATION BUILDING CODE INFORMATION I
I ADDREss 735 Castle Creek or itt Aspen,CO 81611 UNITa 1 PARCEL!.273512237001 M 2015 IRC ❑2015 IBC ❑2015 IEBC 0 Other(Please Explain) REFERENCES FROM 2015 IRCW. r�
LOT BLOCK nrtsueo v,,,.,Castle Creek Duplex Unit 1 Code Editions (As Adopted and Amended) (As Adopted and Amended) (As Adopted ^ CV/A-crawl space ventilation required,sec.R408.1 Access required,R408.4
and Amended) Y� OII•ASPEN EE=emer emergency escape required sec R310.1 -
OWNER NAME 735 Castle Creek Drive LLC BELL EMAIL 9 y
Fire Sprinkler System Existing?Dyes I Required?Et TypeNFPA 13 0NFPA 13 R Cl NFPA 13 D EU=enclosed usable space under stairs shall be%"Gyp,sec R302.7
HAEMEONTACT Alexis REAM CELL 970-615-0269 EMAIL ApekeOforumphi.COm m rvo q ❑No I YP 0PERMIT N0..0106.2018.ARBK G/D=garage/dwelling separation,sec R302.5 and R302.6
0VB❑IV 0 IIIA 0 IIIB❑IIA 0 IIB 0 IA 0 IB I Fire Alarms Installed ID El - - STC=Sound transmission class not less than 45 at dwelling separations,app The City of Aspen
Type Of Construction 0 VA
PROJECT DETAILS ElOWNER 735 CASTLE CREEK DRIVE LLC K
MUM Required Special Inspections High-Strength Bolting Epoxy Anchors 0 Structual Steel Welding RV=roof and rafter ventilation required,R806.1 —
WONKIN ETAIL INTERIOR REMODEL TO A DUPLEX RESIDENCE LOCATED IN THE WEST END OF ASPEN.A PROPOSED UPDATE TO THE BASEMENT, A=attic access 22"x3 to headroom R807.1 These plans must be kept at the
MAIN,AND UPPER LEVEL IS ASSOCIATED WITH THE REMODEL EXTERIOR UPDATES ARE ONLY TO REPLACE WINDOWS AND DOORS. ❑Permanent Micropiles ❑Sprayed Fire-Resistants ❑Other SA=smoke alarms installed to NFPA 72 requirements,sec R314
Use of Building Class of Work Fixture Counts Equipment Checklist Energy Code Compliance !Prescriptive Table 0 Other ADDRESS.. perCity asite or inspection
MI.$600,OOo 735 CASTLE CREEK DRIVE CO=carbon monoxide detector Ordinance 41 series 2008 building
❑Commerical El New 4 T011ets,emets Forceaaideragirysyaem. ❑RESCheckUAAlternative ❑COMCheckUAAlternative -- - SG=safely glazing required,secR308.4 delays may occur.Construction
spp 3,349.50 SF ❑ Commerical
Bathtub — GR=guardrails,36"min ht,4"max opening;req at 30"drop any point w/in 36"
WORKARFAMulti-Family ❑Addition `x Bathtorylwasneasln) —Wall,Suspended,orumtHeaters PARCEL ID 273512237001 shall conform to these plans.All
❑. Single Family❑.Alteration q shower Gas Log Exterior EnergyUse Total Approved On-Site Snowmelt Spa Pool horizontally,sec R312
umirsgmv3,349.50SF 0 Mixed-Use ❑Repair — —Goa ppllancew pP p - - WF =windoenin protection-ntrooperated twindow<24"AFF&80,sec 2"above changes bull shall be approvedicial. by
p LKi[chenSlnk(+Disposal)— (Existing+New) g opening the building official.
tsui1zE ❑ ❑IFFR iDlsnwasner Appliance Vents rade:use o enin control device listed to ASTM F2090,sec R312.2
Tl . ❑Tenant Finish LLagndry Bar,utility Sink—Heat,Reid.Cooling,or Building Type/ I 0 A_❑B 0 F_ 0 E 0 R_ I HR=handrails 34"-38"ht,sec R311.7.8
sruReao Will there be ❑Demolition 2 Clothes washer Absorption unit Occupancy Group g ❑One Family p Two Family
EXTERIOR AAEgO any roof/wall ❑Change Order I1 Floor sink Boners(includes vent) ❑B(A<50) 0 H_ ❑M ❑S_ R Si=stairway illumination,sec R303.7
0 z Floor Drain C C El Townhouse PD=protect against deco sec R317
penetrations? Air Handling ❑I_ ❑tJ P 9 y
NEwse Fro IE Yes water Heater(Pan Reg)—coolmgsystem. REFERENCES FROM 2015 IMC
p��Aa9 0 No —MGasOutlets —ventilation FansSEPARATE PERMITS ARE
—Other
Treatment UNIT DESCRIPTION AS PROPOSED V=bathroom and balanced whole house mechanical ventilation req.
w°ITITxIUTY Wass 937 other Range Hood _ Ordinance 40,2016 REQUIRED FOR ELECTRICAL,
—R of Gas System Outlets 10,198.253E 4545 SF PLUMBING,MECHANICAL,OR
ZONE DISTRICT R-15 —Snowmelt System Sq F[ Gross Area of Building: Gross Area of Unit: ADU BUILDING DESCRIPTION DE=clothes dryer exhaust,sec 504.Makeup air req'd if over 200 CFM
Occupant Load: AS=access and service space for maintenance req'd,sec 306 FIRE SPRINKLER WORK
Project Valuation:Cost of project as defined in Valuation Afadavit. hones:This permit becomes nun and Is there an ADU?❑Yes MA=make up air required if hood exhausts greater than 400 CFM,sec 505.2
ZO Sq Ft of Work Area:Total square footage of area undergoing change or reconfiguration. void If work or construction authorized IM No ET=exhausts terminate 3'from prop line and openings,10'from intakes,
Unit$q Ft:Gross Square Footage,not FAR,of permitted unit. Is not commenced within 1eo days,or 2 1SMOKE ALARMS AND
H-Lofsize:Totalsurveyedsquarefootage ofproperty. tiff construction or work aqua Cie of #Stories Above Grade #Stories Below Grade #Living Rooms 501.3.1
Boned for period of 180 days at
2 Disturbed Exterior Area:Square footage of lot affected by permit application. anytime after work is commenced. Attached Garage Detached Garage Carpport #Kitchens T=intake openings 10'from lot line&contaminant sources(vents,streets), CARBON MONOXIDE
II-NewsgFkTo[aleddedsquarefootegeforadditionstonetllvableornetleasbleseace. abandoned ParkingSpaces2 ParkingSpaces D ParkingSpaces0 #Full Baths 401.4 DETECTORS REQUIRED
a Sq R of Rooms with Utility Work:Total square footage,not FAR,of all rooms with plumbing work. ec 5 2 690 SF #3/4 Baths D=fasten and seal all ductwork per 603.9 THROUGHOUT DWELLING
APPROVALS : #Bedrooms #Full Baths Deck Area REFERENCES FROM 2015 IFGC
SUBMITTAL FEES ISSUANCE FEES ISSUANCE FEES a ral'at Pal sJrr :to�ea #3/4 Baths 2 #1/2 Baths 0 #Bed Baths UNIT PER CITY OF ASPEN
oso je a° #Bedrooms DV=direct vent req'd,sec 303.3
Permit Pen PC x SV 7417/_3 #Kitchens( #Wood Fireplaces CA=combustion air not taken from bedrooms,bathrooms or MUNICIPAL CODE 8.15
Plan Check 9441.25 14525 Parks Impact 0 ZoningP #Other Rooms List303.3
x JRB 2/25/19 (List) storage oor sec appliances
L INSPECTION REQUIRED:
Zoning(sD%) HPC #Gas Appliances 1 #Gas Log50 OD=outdoor appliances must be listed for outdoor use,sec 303.6
Engineering school Red.
487.50 Building x TF 2/21/19 BUILDING ROOMS AND USES BY LEVEL AS PROPOSED(Include Mechanical&Storage) REFERENCES FROM 2015 IECC
CMP(SO%) TDM Impact Fire x TF 10/24/18 - F=new or replacement glazing shall not exceed 0.28 U-Value,NFRC label
fining(SI>%)
9 87.50 1792.25 0 Engineering Basement 001 Bedroom 1,002 Bath 1,003 Laundry,004 Hall,005 Media/Game,006 Boiler,007 Gear Storage, required,Ordinance 40,2016 -Structural steel welding:Field&Shop
Energy code REMP Ped.Amenity D CMP x TK 8/1/18 -- L=75%of lamps in permanently installed lights must be high efficacy,sec -High strength bolting
217 8.7 5 008 Bedroom 2,009 Bath 2,010 Closet 2
Water
Plan Check x SW 1/1_` 101 Ent R404.1 -Epoxy anchors
Lieu 0 stormwater Main Level Entry,102 Kitchen,103 Dining,104 Living,105 Flex Space,106 Master Closet,107 Master Bath, SE=Continuous air barrier required;all exterior joints,cracks,and holes to be -Intumescent paint CMP(505) 1792.25 (Hourly) Housing Cash in
zoning Sanitation x PM 8/20/18 108 Master Bed,109 Guest Room,110 Guest Bath,111 Guest Clo,112 Garage,113 Mudroom,114 Hall caulked,gasketed,sealed,table R402.4.1.1 Spray applied fire resistive materials
Park.Review 100.50 I000niv) stormwater E REFERENCES FROM 2014 NEC
Env.Health
2nd Floor 201 Loft Bedroom EP=electric panel'happy space'30"x36"x78",not in storage,sec 110.26 -Permanent micropiles
Online Review Engineering City use Tax Parks x DR 7/26/18
937.00 (Hourly) City Landscape
GIs county use Tax 1500 Efficiency 3rd Floor Special inspection is required per copy2015 C
Approved UAM 4/1//19
section 17 Inspector to verify that o
Lot Area Deed Restricted To Issue agreement for inspection program to be on
434 Census Code #of Dwellings 67°771261 Additional
eemberae Plans Location Issuance the E® the job site prior to performing any
I CITY OFASPENneen 130S.GALENASTIASPEN,C T01511V RECEIVED inspections.A copy of all Special Inspector
field reports to be on the job site for
07/25/2018 Reviewed By: Date: 11inspectors' q
I OF ASPEN 130 S.GALENA ST I ASPEN,CO�81611 8 FIRE review l requested..Failure ti
ASPEN J—,2018 o
�t in denial of inspection.
BUILDING DEPARTMENT SPRINKLERS
BUILDING DEPARTMENT
S-531:structural steel
ADDRESS:735 Castle Creek Drive#1 PERMIT NUMBER: REQUIRED
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT CONTACT SHEET THE Cu,'Cr Asott
ADDRESS:735 Castle Creek Drive#1 PERMIT NUMBER:
Name AlexisPetre Phoney/U-OIO-ULOM E-m„IAperrellrururflprll.Corll COMMUNITY DEVELOPMENT DEPARTMENT
ilk 2015 mended by Ordinance 00,2016
Name AlexisPetre phone y/U-0I0-ULOM E-ma1lAperre�.lurumpni.com SCOPE OF WORK CHECKLIST WE atyof nswti
y.: eovina'
IIns
Name 735 Castle Creek Drive LLC Phone cell Phone LAND USE QUESTIONS
nape 735 Castle Creek Drive#1 city Aspen stat5CO Z1p81611 If you check an of boxes below, lease consult with the Planner of the Da z.em..<n."vm..mbaamom,.
any p Day before submitting your Pinot,tonermittAmc"uawm,bu,"ram„m"playLd.
MIL permit application.
Aaar ss Does your permit involve any of the following? ma.oaacue.n,"rate;on enter.desire.outdoor minim..rare to cm..number of hours it will rtted to rim eye, .peas. qua"t
Name Phone Cell Phone Partuired Continuous Balanced
ofan approved COA Land Use Review Work involves Landmark Parcel or Historic District Floor Area wnoori It of Bedrooms Number of occupants
aamg ❑ Outdoor ventilation Rate la)Mddn oess City State DIP ❑Work affects net leasable,net livable,or ❑ Located in 100-year flood plain or within 100'of high
E-4Ras non-unit space water mark
Aupress 3,425 soft 4 5 64 rim
`J
❑ Work involves lot splitting or combining a lot ❑ Work involves changes in occupancy to structure
Name Alexis Pete Phone cell Phone M I U-0 10-ULO
Work involves exterior of structure Changes to elevator or stair configuration umber of hour.
n�a"e^^,715 W.Main St.Ste 204 Aspen CO 81611 „iradlntarmiccent ern,
City sbte ZIP aced Period
x hour RegOutdoor Ventilation Rate
E-mail Apetre@forumphl.com El Changing the number of residential units ❑ Changes to the use of existing structure or space pe°
gaare:: ▪ Cha to number or location of
1.33 hrs 162 tfm
sa
me Forum Phi Architecture-steew Wilson Phone cell Phone W/U-L/e-4 I UM onsitnge es parking
OR —
Desired intermittent
Required numberon period Wm 715 W.Main St.Ste 204 city Aspen seete CO 21,81611 , ,Hour pedoa
icicles swilson@forumphi.com ventilation"
Olio hrs
Name Phone Cell Phone
Mailing ADDITIONAL SCOPE OF WORK QUESTIONS
qr=Il0.01 xanagrl+ps x(ry. br+llo x sc
'TAU City some ZIP Does your permit involve any of the following? or=ventilation flow rate,cubic feet per minute fermi
karelss Afloof=noon area in square feet Ift2)
❑ Exterior lighting added or changed ❑� Work involves exterior wall penetrations Nbr=number of bedrooms,not less than one
Bc=D.TS(system coefficient for balanced systems)Name SK Peightal Engineers ,hon,9/U-9L/-961U Cell Phone
Marling p O Box 410 Basal[ C 81621 ❑ Work involves roof penetrations ❑ Work involves digging or excavation
The city of Aspen has created and provided this software smelt/as a reference,Users should obtain assistance from a qualifiedAaaress Ci seat. ZIP professional to verify accuracy and applicability before proceeding.The City of Aspen makes no express or implied warranty
❑ Work adds removes,or changes ❑Work involves restaurant or food service with respect topoeelb software oeydao,rmation contained herein,Tome full extent permissible n,Ce,b the City ofAspen
E-ttnntie Aprosser@sopris.net plumbing fixtures disclaims an responsibility for an dame losses
Atltlresz y gezors,lossf prof without limitation,structural damage,in contract,
for
Disturbs 1,000 sgftor more of soil within Affects parking spaces/meters,loading zones,or alleysfinanciali,e,from
for loss mbusmesse Meft.,ware,profit,anyacren ordecin^ntakenaas aces in of usingthistor
Name MackyMorris-Cornerstone a� Workoc12 hS ❑ �tie fmmthegaegfqrmabllleytqqaethl..gnware,gr from anyareignqraea.Igntakena.are.gleqfa.mgthis RECEIVED
awls�4 i ti Phone den vnone q 10 3 f 20 Y 9- R
e/ 0 occurs in public right of way ❑ Adding structures or systems over utility lines a�
'AV TOBat/.938z c"�I-�'
°ty�� ZIP 71612—
❑Work affects trees or occurs within the ❑ Work within City Mall boundaries 04/17/2019
n5'darel.. 1)-a-hL+i5 (Or frts rS& a c.Ape kk.cal.J.l dripline of a tree
•
ASPEN
•
INSPECTIONS:The General Contractor must schedule Inspections online. BUILDING DEPARTMENT
Please visit www.aspenpitkin.com/Departments/Community-Development-Forms/to do so.
I hereby certify that I have read and examined this application and know the same to he true and correct.All provisions of laws and I
ordinances governing this type of work will be complied with whether specified herein or not.The granting of a permit does not
presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance I
of construction.It is my responsibility to review the approved plans and any comments that are contained thereon and see that the
structure arA/or pr'ct is built raRejgyy�all applicable codes. ALL OUTDOOR LIGHTING
EIooamren � yl}- S( - pace 6 /O// CEIVED MUST COMPLY WITH
❑ Check if you area tested6-0000GGner builder(single-family homes only).You must take a test and complete to ow er/ C THE CITY OF ASPEN LIGHTING CODE
(CITY USE ONLY)Owner builder approved by: Date: Affidavit on file
I CITY OF ASPEN... 130 S.GALENA ST I ASPEN,Cd7�� ill.8
SECTION 26.575.150
"a't''
BUILDING DEPARTMENT RECEIVED
D0 -.\
I CITY OF ASPENAugust2012 130 S.GALENA ST I ASPEN,Cd7'f 11318
Alal'tN1-::\ip
al*2157/ER 9
BUILDING DEPARTMENT
ZONING
2. Approval of fabricator.Approval shall be based upon review of the fabricator's written Field Plan Set Must Be Printed In Color
m procedural and quality control manuals and periodic auditing offabrieution practices by
an approved special inspection agency y,._
n„cmer,wrx SPECIAL INSPECTION AND TESTING AGREEMENT - 3. Completion of fabrication.Upon completion of fabrication,the approved fabricator
shall submit certificate of compliance to the building official stating that the work was
To permit applicants of project requiring special inspection and\or testing per Section 1704 of the performed in accordance with the approved construction documents.
International Building Code(IBC).
Project Address: 735 Castle Creek Permit Number: 0196.2018.arbk G. Building Department Responsibilities
1. Approve special-inspection program.The building department shall approve all
BEFORE A PERMIT CAN BE ISSUED:The owner,or the engineer or architect of record,acting as the special inspectors and special-inspection requirements. The City of Aspen
owner's agent,shall complete two copies of this agreement and the attached Special-inspection and Testing
Schedule,including the required acknowledgments.A pre-construction conference with the parties 2. Enforce special inspection.Work inquiring special inspection and the building
involved may be required to review the special-inspection requirements and procedures. inspector shall monitor the performance of special inspectors.Ris\Her approval,in These plans must be kept at the
addition to that of the special inspector,must be obtained prior to placement of concrete, building site or inspection
APPROVAL OF SPECIAL INSPECTORS:Special inspectors may have no financial interest in the covering of structural steel,or other similar materials.
projects for which they provide special inspections.Special inspectors shall be approved by the building delays may occur.Construction
department prior to performing any duties.Special inspectors shall submit their qualifications and are 3. Review inspection reports.The building official should review special-inspection shall conform to these plans.All
subject to personal interviews for pre-qualification.Special inspectors shall display approved progress and final reports. changes shall be approved by
identification,as stipulated by the building official,when performing the function of special inspector.
4. Perform final inspection.The building official should perform the final inspection and
Special inspection and testing shall meet the minimum requirements of the International Building Code approval for a project[BBC Sec.1093.1]after the furl special-inspection report has been thebuildingofficial.
Section 1704.The following conditions are also applicable: reviewed and approved.
A.Duties and Responsibilities of the Special Inspector t/ /' 0196.2018.arbk SEPARATE PERMITS ARE
Project Address:-7 C 3S Cp,/T/[ rtek Ir.Permit Number:
I. Signify presence at job site.Special inspectors should notify contractor personnel of REQUIRED FOR ELECTRICAL,
their presence and responsibilities at the job site.If required by the building official,they PLUMBING,MECHANICAL,OR
shall sign in on the appropriate form posted with the building permit. ACKNOWLEDGMENTS FIRE SPRINKLER WORK
2. Observe assigned work.The special inspector shall observe assigned work for I bane read and agree to comply with the condons of this agreement
conformance with the building department approved(stamped)design drawings, Special
specifications,and applicable workmanship provisions of the International Building pe Inspection Agency: Signature: Name: Date:
f�Code.Architect\engineer-reviewed shop drawings may be used only as an aid to ���..1
inspection.
For continuous special-inspection,the special inspector shall be on site at all times Owner. Sigsnanue': Printed Name bate
observing the work requiring special inspection.Periodic inspections,if any,must have Macky Morris A ,( 12M 0/201
prior approval based on a separate written plan reviewed and approved by the budding a
department and the engineer or architect of record. Engine&Architect Signature: Printed Name: Data
3. Report nonconforming items.The special inspector shall bring nonconforming items to Forum Phi-Steen Wilson seµ WlGrwIL Steen Wilson 12-10-2018
the immediate attention of the contractor and note all such items in the daily report.If
any item is not resolved in a timely manner or is about to be incorporated in the work,the
special inspector shall immediately notify the building department by telephone or in Contractor Signature: Primed Names Date:
person,notify the engineer or architect,and post a discrepancy notice' cornerstone Construction Jason Schmidt 10/26/2018
4. Provide timely reports.The special inspector shall complete written inspection reports Approved Fabricator: Si
for each inspection visit and provide the reports on a timely basis determined by the gnabue:, _ Primed Name: Date:
•
building official.The special inspector or inspection agency shall famish these reports - • —
directly to the building official,engineer or architect of record,and others as designated. - - . 5 —- —
[IBC Sec.1704.1.2]These reports should be organized on a daily format and may be Inspected Fabricator. Signature: Printed Name: Dote:
submitted weekly at the option of the building official.These reports should include:
a.Description of daily inspections and tests made with applicable locations, tEJ2x)pf m oohed, , e C✓� CQ ��.�.1 p�
b.Listing of nonconforming ites,
c.Report on how nonconforming items were resolved or unresolved as (circle one) Signature: Printed Name: Dam:
applicable, �j
d.Itemized changes authorized by the architect,engineer,and building official if PIT/KIN COUNTY: TF Tony Fusero 2/21/2019
not included in nonconforming items.
RECEIVED
02/19/2019
ASPEN
•
5. Provide Final Inspection Report.The special inspector shall submit a written final BUILDING DEPARTMENT
report documenting required special inspections and correction of any discrepancies
noted in the inspections prior to the final building inspection.
B.Owner Responsibilities.The project owner,the engineer or architect or record,or an agent of the
owner is responsible for employing special-inspection services.The special inspector\agency shall
not be in the employ of the contractor,subcontractor or material supplier.[IBC Sec 1704.1]In
case of an owner\contractor,the special inspector\agency shall be employed an specified by the
building official.
C.Engineer or Architect of Record Responsibilities
1. Prepare special inspection program.The engineer or architect of record shall list the
items for which special inspection is required;and shall indicate any items for which the
IBC or the building official approves periodic inspection and the frequency of such
inspections.
2. Respond to field discrepancies.The engineer or architect of record shall respond to
uncorrected field discrepancies in design,material,or workmanship observed by the
special inspector.
3. Review shop drawings and submit design changes.The engineer or architect of record
shall acknowledge and review for conformance with the construction drawings those
shop drawings that may detail structural information,shall submit to the building official
and to the special-inspection agency written documentation of any verbally authorized
deviations from the approved construction documents,and shall submit revised
documents for building official approval as required.
D.Contractor Responsibilities
1. Notify the special inspector.The contractor is responsible for notifying the special
inspector or agency regarding individual inspections for items listed on the attached
schedule and as noted on the building department approved plans.Adequate notice shall
be provided so the special inspector has time to become familiar with the project.
2. Provide access to approved plans.The contractor is responsible for providing the
special inspector access to approved plans.
3. Retain special inspection records.Upon request,the contractor is also responsible for
retaining,at the job site,all special inspection records completed by the special inspector.
E.Inspection of Fabricators
1. Fabrication of structural assemblies and members.Where fabrication of structural
load-bearing members and assemblies is being performed on the premises of a
fabricator's shop,BC Section 1704.2 shall require special inspection of the fabricated
items.
2. Fabrication and implementation procedures.The special inspector shall verify that
the fabricator maintains detailed fabrication and quality control procedures that provide a
basis for inspection control of the workmanship and the fabricator's ability to conform to
approved construction documents and reference standards.The special inspector shall
review the procedures for completeness and adequacy relative to code requirements for
fabricator's scope of work.
F.Approved Fabricator Responsibilities
1. Fabrication exempt inspections.Special inspections are not required where work is
done on the premise of a fabricator registered and approved to perform such work ALL OUTDOOR LIGHTING
without special inspection. MUST COMPLY WITH
THE CITY OF ASPEN LIGHTING CODE
2 SECTION 26.575.150
0 7
ak2>57/1h9
ZONING