Loading...
HomeMy WebLinkAboutFile Documents.905 Chatfield Rd.0111.2018 (157).ARBK fantech® ••• a systemair company DEDPV-705 DRYER EXHAUST FAN Document type: Product card Document date: 2016-12-06 Item no. 46005 Generated by: Systemair Online Catalogue Description •Dryer Exhaust Duct Power Ventilator(DEDPV) 1I •Pressure-sensing switch automatically turns on the fan •LED indicator display panel •Temperature limit switch •Short duct junctions and qty(4)4"fast clamps for easy installation and maintenance. •Performance certified by HVI {, •cULus certified •Safety certified by UL to the DEDPV supplement to UL705 •Safety certified by UL to CSA C22.2 No.113 Application The Fantech dryer exhaust fans have been specially designed to solve the problems - # caused by long duct runs on clothes dryers.According to dryer manufacturers and some local building codes,exhaust fans should be added in the dryer duct run when { the length of the duct exceeds 35 feet with no bends,30 feet with one bend or 25 I I feet with two bends. How it works I 1- When the dryer is on,Fantech's patented pressure sensing switch automatically turns • the exhaust fan on.The warm,moist air in the dryer duct is exhausted out of the ; M building quickly.The dryer exhaust fan monitors the status of the dryer and will turn itself off when the dryer stops.A wall-mounted indicator panel(specific models)with LED display lets homeowners know that the fan is fully operational. Technical parameters Nominal data Voltage 120 V Frequency 60 Hz Phase 1 — Input power(P1) 71.9 W Current 0.75 A Max.airflow 173 cfm Fan impeller speed 2559 r.p.m. Weight 10 lbs. Altitude 0-84000 po. Temperature data Max.temperature of transported air 167 °F Protection/Classification Insulation class B Enclosure class,motor IP44 IP Others HVI,UL to the DEDPV Certificate supplement to UL705, UL to CSA C22.2 No. 113 Performance Diagrams RECEIVED 12/03/2018 Name: 05 DRYER UST FAN Item no.: 005 Document type: yp Product and I DocumentI dat: 2016-12-06461/3 I Generated by:Online catalogue ASPEN BUILDING DEPARTMENT 2 1.6 0.8 0.4 0 30 60 90 120 150 180 Q[cfm] 50 a 25��— — 0 0 30 60 90 120 150 180 Q[cfm] Hydraulic data Working point Q Ps P n I SFP U [cfm] [in.wg] [W] [r.p.m.] [A] [W/(cfm)] [V] 77.9 1.1 62.8 2877 - 3.62 120 Dimensions B E , IL / F JI-J1!t1 I l J•-J l -1 C iii 1 ' A B C D E F G DEDPV-705 9 11/16 2 4 28 9/16 10 4 1/32 Dimensions are in inches Wiring RECEIVED 12/03/2018 Name: DEDPV-705 DRYER EXHAUST FAN I Item no.:46005 2/3 Document type: Product card I Document date: 2016-12-06 I Generated by:Online catalogue ASPEN BUILDING DEPARTMENT FAN CAP FAN OUTPUT TOP FAN NEUTRAL 120VAC HOT HALL"+" SUPPLY HALL SIGNAL POWER NEUTRAL f HALL' R M I TH1 TH2 N1 N2 H1 H2 H3 ( o p 4 0 0 0 0 0 0 0l 1 2 3 4 5 6 7 8 9 10 +5V • RB 121K Accessories Accessories UEV4 Soffit Vent(411119) DBLT4W Lint Trap(46000) Documentation A483443 DEDPV OIPM EN FR.pdf(989,81kB) 46005.dxf(336,59kB) I411958 DEDPV White paper Fantech EN.pdf(367,62kB) h450608 DEDPV-705 Submittal Sheet EN.pdf(137,49kB) RECEIVED 12/03/2018 Name: DEDPV-705 DRYER EXHAUST FAN I Item no.:46005 r n I 3/3 Document type: Product card I Document date: 2016-12-06 I Generated by:Online catalogue AS r E I y BUILDING DEPARTMENT