Loading...
HomeMy WebLinkAboutFile Documents.520 E Hyman Ave.0158.2018 (53).ARBK ISOKERN FIREPLACE AND CHIMNEY SPECIFICATIONS: _ 33" REVISIONS BY--- 4 " I.MANUFACTURER: 4 A.Earthcore Industries,LLC.,Jacksonville,FL(Telephone 800-642-2920) L I II.PRODUCT DESCRIPTION: f A.Modular refractory precast fireplace and chimney components. 16" 28 4" 1.Designed for field assembly as a fireplace and chimney unit. 2.All interlocking parts necessary for assembly of a complete firebox and smoke dome. 3.Interlocking double module chimney components(DM). \ 8" III.MATERIALS: A.Light weight concrete of a proprietary mixture of Icelandic volcanic pumice / 63 4" 63 a" aggregate and cement for precast firebox,chimney block and flue liner components. 1.Compressive Strength:Firebox and Chimney Block:972 psi. / 2.Compressive Strength:Flue Liner:1175 psi. / 101" 1 B.Premixed(dry)EARTHCORE ADHESIVE. 30 / TYP. 31 " z 34 Z" 1.Tested per ASTM C109,ASTM C307,and ANSI 118.4. / C.Standard 1 1/8"medium duty refractory brick to line firebox interior. i D.Standard cast iron poker-style damper(optional top mount or in-line damper available). / o //,�/ // //, , m c.i IV.INSTALLATION: 3" I J M A.Reference manufacturer's installation instructions for standard configurations,weights, ° -f a a a sizes and installation details. 1-E B.Suitable masonry foundation;noncombustible hearth extensions must be provided. =0 N.,,L.,.,C.Suitable combustible floor foundation as a Fire-Lite application;noncombustible z"a v hearth extensions must be provided. SECTION A-A FRONT VIEW cn J M c2 11 D.Unit to be assembled on site per manufacturer's illustrated instructions. a>M M 1.Premixed EARTHCORE ADHESIVE is used at all joints between components. I d z v v;� 2.Firebox to be lined with a minimum 1 1/8"rated firebrick. - - f 0_0 0' y E.Standard fireplace and chimney units listed for"zero clearance"to uninsulated o,0 x wood framing members. CD-D I-u F.A 11/2"minimum clearance envelope to combustible materials is recommended. - 27 4 _ 25 4 G.A 3"minimum clearance envelope to insulation required. V.CERTIFICATION: A.Warnock Hersey/Intertek Testing Services Report No.3159656MID-008. B.Meets or exceeds U.L.103HT;U.L.127-08;ULC 5610-87;ANSI 2.11. 36 s° VI.CODE COMPLIANCE: PLAN -SECTION and ELEVATION of 43" -J A.ICC.No.ESR-2316/LARR#25483/MEA N.Y.C.241-90-E. ISOKERN 36" [WIDE] FIREPLACE w B.Standard fireplace and chimney units listed for"zero clearance"to uninsulated wood framing members. PLAN VIEW Note:Isokern components are a natural material SCALE:3/4"=1'-0" co and slight variations in dimensions may occur. These E (I) =p should be no more than g'. a) z w >, cn 0 >, U E Q U LL 13 0 33" - 43" - m I- 44I 44,,I U Q 1fA 1 , 1 L 1 , nEt u a ff ii Q 16" 73" 28 4" 16" 28 y' • \ 8" \ g" / 63 4" 63 4' / 63 y' 63 4" 30" • 101" 31 1" 30" /, 10 2" 31 1" / TYP. 2 34 z" / TYP. 2 34 Z" / / x v7 o //Z//////// ///Y///// 0 H w H SECTION A-A FRONT VIEW SECTION A-A FRONT VIEW rDRAWNRY JMK RELEASE DATE H L - 1 - 1-1 H SCALE- 1 09/01/09 3/4"=1'-0" 33 4 251 374 1 25 " 4 /1- 14 nE w 1 I PLAN, SECTION and ELEVATION of L. - 43 a" PLAN, SECTION and ELEVATION of LL 478" �j SHEET ISOKERN 42" [WIDE] FIREPLACE 49" ISOKERN 46" [WIDE] FIREPLACE 53" 51,0rEIVED SCALE:3/4"=1.-0" PLAN VIEW SCALE 3/4"=r-0" PLAN VIEW 06/11/2018 J ASPEN BUILDING DEPARTMENT Assembled Firebox & Smoke Dome Dimensions 36, 42 & 46 B G I / \ P A _ _ D E � Li — F — I LI J A SIDE VIEW FRONT VIEW PLAN VIEW MODEL A B C D E F G I J MINIMUM FRAMING WEIGHT 36 43" 25 1/4" 63 1/4" 31 1/2" 36 1/8" 27 1/4" 33" 201/4" 5" (46"W)x(65"H)x(26 3/4"D) 1205 lbs 42 49" 25 1/4" 63 1/4" 31 1/2" 43 1/8" 33 1/4" 33" 201/4" 5" (52"W)x(65"H)x(26 3/4"D) 1325 lbs 46 53" 25 1/4" 63 1/4" 31 1/2" 47 1/8" 37 1/4" 43" 201/4" 5" (56"W)x(65"H)x(26 3/4"D) 1450 lbs Firebox & Smoke Dome Components List Top Plate-Medium Part No. Model Qty Top Plate-Large M77 36 1 Part No. Model Qty M77 42 1 M81 46 1 25 1/4" 25 1/4" 10 3/4" 33„ 10 3/4" 43" 43/4" 43/4" �� ,' 06/11/2018 7 ASPEN BUILDING DEPARTMENT / .. 33" 44 A } ANGLE IRON SUPPORT; FRONT&REAR w 3" 28 a" 1 L i 8" tFFh#F 4E#I I I 1 I FEEEI+F+E� 63`" SUPPORT RANGE 31' % 34 2" (SUN SIDE WALLS 403" -% 3" A SECTION A-A FRONT VIEW 141 Hole in Tap Plate far Flue i PLAN,SECTION and ELEVATION of /111 25 a" ISOKERN 42"SEE-THRU FIREPLACE G e LI 43 B" I ba iaimer 49" A.brwigs fan ma'am haxn tee far ilhen.m pepam cal BOM B.Emtha m m.vy4alanW elm.thsof,shall mat he heldkble 58 an fan W etartalm .tl damages ar ex,.ceesgm VIEW PLAN .f the me.f the fS.bm ha s or areey spteme. YG�1 C.bw!ge we the sale properly of 15a11...1...Ap rmm.ee...WWI..1a alma y prahi.b.Ta met'<earneal your cue.mhmmeaIN n,though ref regaY.,Eurfkore man.N The we of am.uiml w.a..eymen Net.Leah.cmpamme wemWact.S from aan"sal mat.! and eight mere..in denemi.,.may ae..phase watn.lmle ,......bean owe than k. / DWG.NO. SCALE " /REVISIONS BY" ® ST2.2 3/8" = 11R r El E D eeee PHIwPS INDUSTRIAL BLVD DESCRIPTION SONVILLE FLORIDA 32258 Fireplaces and Chimney Systems �' 6/11/2018 Standard 42-See-Thru A PRODUCT OF EARTHCORE INDUSTRIES,LLC FAX MN)383340e m DATE DB: ASPEN Q01/10/2011 JMK g DIA@ DEPARTh9ENN