INSTALLATION MANUAL
For the CROSSFIRE'"' Brass Burners and
Ignition Syste„ rEIVED
04/20/2018
www.Warming-Trends.com 1 303 346 2224 I info@warming-trends.com ASPEN 1
BUILDING DEPARTMENT
General Warnings and Information 3
Selecting a location for your fire feature 4
Construction of enclosure 4
General Fire Pit Installation 4
Media Installation 5
Fire Feature Operation 6
Lighting Instructions 6
Maintenance 6
Troubleshooting 7
Warranty 7
INSTALLATION FOR ALL MODELS
60K-120K BTU System with FLKV12 8
(Match Lit,Standard Ignition, Premium Ignition)
121 K-249K BTU System with FLKV34 and FLKV34FIT180 12
(Match Lit,Standard Ignition, Premium Ignition)
250K-299K BTU System with DFLKV34 and DFLKV34FIT250 15
(Match Lit,Standard Ignition, Premium Ignition)
300K+ Higher BTU System with DFLKV34 and DFLKV34FIT300 20
(Match Lit,Standard Ignition, Premium Ignition)
Push Button Ignition Installation 25
Parts Glossary 27
CERTIFIED UNITS ICC ICC ICC
Compliance with the following codes: LE:sTh�--+�
1.2015,2012,and 2009 International Fire Code®(I
•
2.2015,2012,and 2009 International Fuel Gas Code®e®(IFGC)
3.2012 and 2009 Uniform Mechanical Code®(UMC)* C PMG LISTED
4.2010 Natural Gas and Propane Installation Code**
*Uniform Plumbing Code is a copyrighted plublication of the Internaional Association of Plumbing and Mechanical Officials ICC-ES Report PMG-1 213
**Copyrighted publication of Candian Standard Association
Compliance with the following standards:
1.ANSI Z21.97/CSA 2.41-2014 Outdoor Decorative Gas Appliances
CERTIFIED MODELS Model#CFB180LP with Premium 24 Volt electronic ignition system
MATCH LIT Model#CFB18ONG with Premium 24 Volt electronic ignition system
Model#CFB6OLP as match lit Model#CFB290LP with Premium 24 Volt electronic ignition system
Model#CFB6ONG as match lit Model#CFB29ONG with Premium 24 Volt electronic ignition system
Model#CFB120LP as match lit
Model#CFB12ONG as match lit 24 VOLT ELECTRONIC IGNITION SYSTEMS-Premium-High Capacity
Model#CFB180LP as match lit Model#CFB300LP with Premium 24 Volt electronic ignition system
Model#CFB18ONG as match lit Model#CFB300NG with Premium 24 Volt electronic ignition system
Model#CFB290LP as match lit
Model#CFB29ONG as match lit 24 VOLT ELECTRONIC IGNITION SYSTEMS-Standard-Standard Capacity
Model#CFB6OLP with Standard 24 Volt electronic ignition system
3V BATTERY OPERATED UNITS Model#CFB6ONG with Standard 24 Volt electronic ignition system
Model#CFB6OLP with 3 Volt Battery Operated Electronic Ignition System Model#CFB120LP with Standard 24 Volt electronic ignition system
Model#CFB6ONG with 3 Volt Battery Operated Electronic Ignition System Model#CFB12ONG with Standard 24 Volt electronic ignition system
Model#CFB120LP with 3 Volt Battery Operated Electronic Ignition System Model#CFB180LP with Standard 24 Volt electronic ignition system
Model#CFB12ONG with 3 Volt Battery Operated Electronic Ignition System Model#CFB18ONG with Standard 24 Volt electronic ignition system
24 VOLT ELECTRONIC IGNITION SYSTEMS-Premium-Standard Capacity 24 VOLT ELECTRONIC IGNITION SYSTEMS-Standard- High Capacity
Model#CFB6OLP with Premium 24 Volt electronic ignition system Model#CFB290LP with Standard 24 Volt electronic ignition system
Model#CFB6ONG with Premium 24 Volt electronic ignition system Model#CFB29ONG with Standard 24 Volt electronic IVED
Model#CFB120LP with Premium 24 Volt electronic ignition system Model#CFB350LP with Standard 24 Volt electronic i ii4s
Model#CFB12ONG with Premium 24 Volt electronic ignition system Model#CFB35ONG with Standard 24 Volt electronic on system
04/20/2018
2 ASPEN
BUILDING DEPARTMENT
PARTS LIST FOR CERTIFIED MODELS
CROSSFIRE'BRASS BURNER MATCH LIT SYSTEMS
Model#CFB6OLP:CFB6OLP burner,plate or pan,lava rock
Model#CFB6ONG: CFB6ONG burner,plate or pan,lava rock
Model#CFB120LP: CFB120LP burner,plate or pan,lava rock,gas reducing orifice
Model#CFB12ONG: CFB12ONG burner,plate or pan,lava rock,gas reducing orifice
Model#CFB180LP: CFB180LP burner,plate or pan,lava rock,gas reducing orifice
Model#CFB18ONG:CFB18ONG burner,plate or pan,lava rock,gas reducing orifice
Model#CFB290LP:CFB290LP burner,plate or pan,lava rock,gas reducing orifice
Model#CFB29ONG: CFB29ONG burner,plate or pan,lava rock,gas reducing orifice
CROSSFIRE' BRASS BURNER 3V BATTERY OPERATED SYSTEMS
Model#CFB6OLP-3VIK: CFB6OLP burner,plate or pan,lava rock,3 Volt Battery Operated Electronic Ignition System
Model#CFB6ONG-3VIK:CFB6ONG burner,plate or pan,lava rock,3 Volt Battery Operated Electronic Ignition System
Model#CFB120LP-3VIK:CFB120LP burner,plate or pan,lava rock,3 Volt Battery Operated Electronic Ignition System
Model#CFB12ONG-3VIK:CFB12ONG burner,plate or pan,lava rock,3 Volt Battery Operated Electronic Ignition System
CROSSFIRE' BRASS BURNER 24 VOLT ELECTRONIC IGNITION SYSTEMS-Premium-Standard Capacity
Model#CFB6OLP-P24VIKSC: CFB6OLP,plate or pan,lava rock,Premium 24 Volt standard capacity electronic ignition system
Model#CFB6ONG-P24VIKSC: CFB6ONG,plate or pan,lava rock,Premium 24 Volt standard capacity electronic ignition system
Model#CFB120LP-P24VIKSC: CFB120LP,plate or pan,lava rock,Premium 24 Volt standard capacity electronic ignition system
Model#CFB12ONG-P24VIKSC:CFB12ONG,plate or pan,lava rock,Premium 24 Volt standard capacity electronic ignition system
Model#CFB180LP-P24VIKSC:CFB180LP,plate or pan,lava rock,Premium 24 Volt standard capacity electronic ignition system
Model#CFB18ONG-P24VIKSC: CFB18ONG,plate or pan,lava rock,Premium 24 Volt standard capacity electronic ignition system
Model#CFB290LP-P24VIKSC: CFB290LP,plate or pan,lava rock,Premium 24 Volt standard capacity electronic ignition system
Model#CFB29ONG-P24VIKSC: CFB29ONG,plate or pan,lava rock,Premium 24 Volt standard capacity electronic ignition system
CROSSFIRE' BRASS BURNER 24 VOLT ELECTRONIC IGNITION SYSTEMS-Premium-High Capacity
Model#CFB300LP-P24VIKHC: CFB300LP,plate or pan,lava rock,Premium 24 Volt high capacity electronic ignition system
Model#CFB300NG-P24VIKHC: CFB300NG,plate or pan,lava rock,Premium 24 Volt high capacity electronic ignition system
CROSSFIRE' BRASS BURNER 24 VOLT ELECTRONIC IGNITION SYSTEMS-Standard-Standard Capacity
Model#CFB6OLP-24VIKSC: CFB6OLP,plate or pan,lava rock,Standard 24 Volt standard capacity electronic ignition system
Model#CFB6ONG-24VIKSC: CFB6ONG,plate or pan,lava rock,Standard 24 Volt standard capacity electronic ignition system
Model#CFB120LP-24VIKSC: CFB120LP,plate or pan,lava rock,Standard 24 Volt standard capacity electronic ignition system
Model#CFB12ONG-24VIKSC: CFB12ONG,plate or pan,lava rock,Standard 24 Volt standard capacity electronic ignition system
Model#CFB180LP-24VIKSC:CFB180LP,plate or pan,lava rock,Standard 24 Volt standard capacity electronic ignition system
Model#CFB18ONG-24VIKSC:CFB18ONG,plate or pan,lava rock,Standard 24 Volt standard capacity electronic ignition system
CROSSFIRE' BRASS BURNER 24 VOLT ELECTRONIC IGNITION SYSTEMS-Standard-High Capacity
Model#CFB290LP-24VIKHC:CFB290LP,plate or pan,lava rock,Standard 24 Volt high capacity electronic ignition system
Model#CFB29ONG-24VIKHC:CFB29ONG,plate or pan,lava rock,Standard 24 Volt high capacity electronic ignition system
Model#CFB300LP-24VIKHC:CFB300LP,plate or pan,lava rock,Standard 24 Volt high capacity electronic ignition system
Model#CFB300NG-24VIKHC:CFB300NG,plate or pan,lava rock,Standard 24 Volt high capacity electronic ignition system
GENERAL WARNINGS GENERAL INFORMATION
WARNING:YOU MUST READ OWNERS MANUAL IN ITS ENTIRETY PRI- Carefully follow the instructions in this manual to prevent personal injury or
OR TO INSTALLATION AND/OR OPERATION. property loss.Instructions are updated as needed.It is the installer's respon-
WARNING:FOR OUTDOOR USE ONLY. sibilityto periodically review instructions for applicable updates.
WARNING:Improper installation,adjustment,alteration,service,or WARNING:This Owner's Manual contains critical information for the safe
maintenance can cause injury or property damage.Read the installation, installation and operation of the fire features listed in this manual. All instruc
operating,and maintenance instructions thoroughly before installing or tions must be strictly followed for safe installation and operation. Warranty is
servicing this equipment. void if not followed.
WARNING:Do not store or use gasoline or other flammable vapors and WARNING:It is the installer's responsibility to ensure a safe installation and
liquids in vicinity of this or any other appliance. to educate the end user as to proper operation.Installer must leave this
manual with the end user.
WARNING:LP-cylinder not connected for use shall not be stored in the WARNING:We suggest that our products be installed by professionals
vicinity of this appliance. that are locallylicensed bythe authorityhavingjurisdiction ingas piping.
p p 9•
WARNING:If you smell gas: We suggest that our products be serviced annually by a licensed plumber.
• Shut off gas to appliance. Installer must follow all instructions carefully to ensure proper performance
and safety.Warming TrendsTM is not responsible for your actions.
• Extinguish any open flame. WARNING:Never alter product or configuration in any way. Alterations can
• If gas odor continues,keep away from appliance and immediately damage the product and cause harm to the end user. Warranty is void if any
call gas supplier or fire department. modification is made to product.
WARNING:FOR REMOTE CONTROL USE:To prevent accidental startup
PARSON MONOXIDE HAZARD from unwanted Remote Control signals it is the responsibility of the end user
A DANGER
rnis appliance can produce carbon monodde to turn off power to electric outlet for the remote- t�,RG1-CE1VE D
wAkh has no odor fire-pit is not in use via wall switch or breaker.
Using it in an enclosed space can MN you WARNING:Product is not intended to be a starter for wood or other combus-
Never use this appliance In an enclosed space tibles. 0 4/2 0/2 01 8
such as a Camper,tent,car or home.
ASPEN 3
BUILDING DEPARTMENT
FIRE PIT CLEARANCES
WARNING:It is the responsibility of the installer to follow ALL LOCAL • 36"horizontally from any structure or combustibles.
CODES concerning the installation and operation of the fire pit.In the ab-
sence of local codes,please follow: • Overhead clearance should be a minimum of 120".
• Fixed piping system:The National Fuel Gas Code,ANSI Z223.1/ • Choose a location that allows easy access for installation and
NFPA 54 or International Fuel Gas Code. maintenance of the fire pit.
• Electrical ground:The National Electrical Code,ANSI/NFPA 70. • Pick a location that allows sufficient horizontal room to enjoy the
fire pit while allowing a safe distance from the heat and flame.
WARNING:Only use gas/fuel type specified for this fire pit.See label on the
burner.Verify correct gas/fuel type and pressure.Never use an alternative • Always consult with local municipality regarding any local code
fue,included but not limited to biofuel,ethanol,lighter fluid or any other requirements
alternative fuel other than Liquid Propane or Natural Gas.
WARNING:Gas pressure and type should be checked prior to use and
installation. CONSTRUCTION OF ENCLOSURE
WARNING:All fire pits must have a gas shutoff on the outside of the fire
MATCH LIGHT Minimum Maximum pit to allow for emergency shut off and maintenance.
WARNING:For electronic ignition models,there must be an electrical shut
Natural Gas 3.5"W.C. 7.0"W.C. off(wall switch or breaker)on the exterior of the fire pit or on adjacent wall
to allow for emergency shutdown and maintenance.Verify correct power
Liquid Propane 11.0"W.C. 13.0"W.C. supply.
WARNING:Always use proper materials and construction for gas supply,
STANDARD-24VIKSC Minimum Maximum power and enclosure.Materials must be non-combustible in both initial
&24VIKHC installations as well as overtime.
WARNING:For electronic ignition models requiring power supply-a
Natural Gas 3.0"W.C. 5.0"W.C. qualified,licensed electrician must install power supply.An outdoor NEMA
rated GFCI Receptacle outlet should be installed on the interior of the
Liquid Propane 8.0"W.C. 12.0"W.C. enclosure above grade to supply power to system.
WARNING:The enclosure is recommended to incorporate 1 vent on at
3V-3VIK Minimum Maximum least two opposing sides(2 vents total)at a minimum size of 18 sq.inches
each(Example:3"x 6"or larger).Installation of the vents in the mid to
Natural Gas 4.5"W.C. 10.0"W.C. lower area of the enclosure is recommended.Ventilation allows for heat
and/or residual fuel to escape.Failure to properly vent enclosure may
Liquid Propane 11.0"W.C. 13.0"W.C. result in the fire pit overheating or explosion.Overheating could lead
to heat damage to internal components.Some enclosures may require
more ventilation based on material,size,and extended use.The vent may
PREMIUM-P24VIKSC Minimum Maximum serve as a drain as well when installed at bottom sidewall to prevent water
&P24VIKHC build up. Always consult with local municipality regarding any local code
requirements
Natural Gas I 3.5"W.C. 14.0"W.C. WARNING:The interior space of the enclosure surrounding the valve box
Liquid Propane 8.0"W.C. 14.0"W.C.
cannot be filled with any material(gravel,crushed rock,concrete,etc.).
WARNING:The fire pit assembly should be recessed 4"-6"from the top
of the enclosure to protect flame from being blown out.Some areas may
SELECTING A LOCATION FOR YOUR FIRE FEATURE require deeper recession.
WARNING:All fire pits,match lit kits,spark ignition,and electronic igni- WARNING:The enclosure must be constructed on a stable surface.The
tion systems are designed and intended for outdoor use only. weight of the fire feature must be supported by the plate or pan and
WARNING:For electronic ignition models,there must be an electrical not by any control/valve box.For electronic ignition models the control/
shut off(wall switch or breaker)on the exterior of the fire pit or on adja-
cent wall to allow for emergency shutdown and maintenance.Distance damage to the controls inside the box.Installer is responsible for ensuring
may be determined by local code. there is enough space for electronics-see technical drawings provided by
manufacturer.Installer is responsible to ensure that the structure is level.
WARNING:All fire pits must have a gas shutoff located outside of the fire Blocks,bricks or L-brackets can be used to build a support ledge for the
pit to allow for emergency shut off and maintenance. system plate or pan.
WARNING:Select a location where the fire pit can be attended during WARNING:It is the responsibility of the installer to provide proper installa-
operation.Never leave an operating fire pit unattended or by someone tion to allow for easy accessibility for service and/or repairs. Installer must
not familiar with its operation or emergency shut off locations. not build capstone inner ledge over outer lip of plates or pans(unless ac-
WARNING:Both children and adults should be alerted to the hazards cess panel door or alternate access is incorporated). Building capstone in
of high surface temperatures and should remain a safe distance away to ner ledge over outer edge of plates or pans will impede access to system
avoid burns and clothing ignition. and result in the need to crack capstones to gain access.Warming Trends
is not responsible for damage to enclosure for any reason whatsoever.
WARNING:Young children should be carefully supervised when they are
in the area of a fire pit.
WARNING:Clothing or other flammable materials should not be placed GENERAL FIRE PIT INSTALLATION
on or near fire pit. WARNING:Read all warnings prior to installing your fire feature
WARNING:Fire pits create very high temperatures-Combustibles must WARNING:All gas products should be installed by qualified professionals
be located far enough away that there is no risk of ignition. that are locally licensed by the authority having jurisdiction in gas piping.
IMPORTANT:It is recommended that material such as granite,marble or WARNING:We suggest that our products be serviced ar EEIVED
other dense stone be kept an appropriate distance away from flame due licensed plumber. ��
to risk of cracking.Manufacturer is not responsible for damage to any fire WARNING:It is the installer's responsibility to follow installa�Q� ��II��u��- //2 018
pit material for any reason. tions carefully in order to ensure a safe installation,safe operVr r aifdaFe
ongoing servicing. ��❑
4 WARNING:You must confirm this appliance is built for gas use-
IVatlrll�l EN
BUILDING DEPARTMENT
Gas or Liquid Propane.Do not use Natural Gas appliance with Liquid Pro- MEDIA INSTALLATION
pane or Liquid Propane appliance with Natural Gas.Refer to the labeling
on the appliance to confirm gas type. WARNING:Only use approved decorative media(glass,lava rock,ceramic
log sets,etc.)that have been manufactured for specific use in fire features.
WARNING:Fuel line sizing is the responsibility of the installer and must
be able to supply the stated maximum BTU listed for each product. WARNING: Media must be le or larger in size to prevent media from falling
into gas orifices and blocking flow of gas out of jets. Use approved media only.
WARNING:Gas Plumbing Connections:Use only joint compound or
thread sealant or tape specific to gas use that is resistant to all gases.Apply WARNING:Burner and jets can be covered by 1 "to'//"of media above
joint compound,thread sealant or tape to all male pipe fittings only and jets.PLEASE NOTE-covering over jets more than 1/a"to 1/2"may create
DO NOT use on FLARED fittings.Be sure to tighten every joint securely. back pressure and gas leakage through air cross holes resulting in pooling
of gas under the fire feature which can result in explosion.Also note that
WARNING:To prevent damage to burner,unhook fire feature from gas flame pattern will be affected by any media coverage over gas orifice jets up
supply during pressure leak tests of the fire feature. to and including smothering of flames.
WARNING:Before use,be sure to test all gas connections for leaks.Do WARNING: In rare cases,it is possible to create an unusual flame pattern
not use fire feature if there is evidence of leaking gas. If leak is suspected, from media that could damage your enclosure.Enclosure damage from an
turn off main gas supply immediately and call a qualified gas technician open flame fire feature is not covered under any warranty.
to repair.
WARNING: When using electronic ignition systems please pay particular
WARNING:During Media Installation-when filling the pan with lava rock attention to keeping media away from the pilot assembly area and/or away
and/or decorative glass and/or any covering material including log sets, from wind screen of pilot assembly.Incorrect media installation that blocks
the instructions for Media must be followed. pilot assembly will cause the pilot flame to suffocate,blocking of thermal
WARNING:For electronic ignition systems,which have an extended sensor and/or a delay in main burner ignition.
or detached valve box,the area in which the valve box is installed must WARNING: The fire pit is designed to use approved media that is correctly
conform with all installation requirements,including but not limited to installed over the burner to achieve proper combustion.Use of any media
location,construction,venting and local codes.Failure to do so may result outside of the approved media sold by Warming Trends may void warranty
in personal injury,property damage or explosion. and effect proper operations.
WARNING:If using an LP bottle/tank,position bottle/tank at safe dis- ---
tance away from flame.Do not place LP bottle/tank inside the enclosure.
WARNING:Use only the key provided to turn the gas valve.Use only '4?Jr-
hand strength to turn the gas key valve.Never use tools to turn the gas + Install enclosure and fire feature
valve.If key valve will not turn by hand,do not try to repair it.Contact a per instructions provided by
qualified gas technician.Forcing or attempting to repair valve may cause manufacturer.
fire or explosion. t =
1.Verify correct gas type(gas supply should match burner type.)
2.Verify correct pressure.
3. Purge gas lines of air,water and debris. .,. ,- Apply media per instructions by
pouring media around burner
4. Perform all leak test with leak detector or leak reactant on main first,then pushing media towards
gas supply and repair leaks as necessary.
the gas jet orifices making sure
5. For 24V electronic ignition models have a qualified electrician media does not fall into the gas
install proper power supply following all local codes. jet orifices.Check each gas jet
b.Shut off Gas Supply and Power to fire-pit. " orifice prior to lighting to be sure
no media has fallen into gas jet
7. Inspect flex line for punctures or breaks in lines. '- orifices.
8.Connect fire-pit to main gas supply.Avoid sharp bends with flex
line to prevent whistling. �. g ' 9
9. Position burner safely with access to all gas connections for testing. # • . .4 '� _ LLTiTs�,r
10.Turn on gas supply and perform leaktest on all connections and re- '-'� •o•••• ����`@��
pair as needed.See detailed connection guide for your specific model. c��•��f >. ! :�
11. Light burner. ' r--'1 -
12. For electronic ignition models,apply proper power supply. k
Electronic Ignition models can either be hard wired into main .
power supply or plugged into NEMA Rated,above grade,out-
door specific,GFCI outlet/receptacle.Electrical can be used in For All Electronic Ignition Systems:Keep pilot assembly screen free
combination with on/off light switch(no dimmers)and/or remote and clear of all media.Media should be piled no more than halfway
control receivers. up screen only(not over full amount of screen)so that pilot gas orifice
13.Once fire pit is lit,perform leak test on all gas connections. opening is above media coverage allowing for pilot flame to easily reach
Repair as needed. gas jet orifice.
For Ceramic Log Sets:Place logs
14.Turn off fire pit and allow to cool. on top of lava rock base according
15.Set burner into properly constructed enclosure. to preference and desired flame
pattern. For electronic ignition
16.Apply media as per installation instruction. systems do not block,cover or
17.Complete final verification of correct operation and lighting. ` obstruct pilot assembly.Blocking,
covering or placing ceramic logs
18. Review safety manual with end user and instruct end user not to - ilk. too close to pilot may cause exces-
change/modify fire pit or media in any way. sive heat on pilot causin system
19. Leave manual with end user. to fail.T �_VED
warrant
WARRANTY REQUIREMENT:Warranty is void if
valve box for any/all electronic ignition system is opened 04/20/2018
or tampered with in any way.See warranty section for full
warranty requirements. ASPEN 5
BUILDING DEPARTMENT
FIRE FEATURE OPERATION LIGHTING INSTRUCTIONS FOR:
WARNING:If you do not follow these instructions exactly,a fire or explo 3V Battery Operated System,24V Premium Electronic Ignition System
sion may result causing property damage,personal injury,or loss of life. &24V Standard Electronic Ignition System
WARNING:Before use,be sure to test all gas connections for leaks.Do 1. STOP!Read all the safety information and warnings in the owner's
not use fire pit if there is any evidence of leaking gas.If leaking gas sus manual before attempting to light fire feature.
pected,turn off the main gas supply and repair. 2. Before operating appliance ensure the manual gas shutoff valve is open.
WARNING:If using an LP bottle,position at safe distance away from flame. 3. Prior to turning appliance on visually inspect fire feature to ensure
WARNING:Do not place LP bottle inside enclosure. debris such as leaves or other combustible material has not collected
inside the feature which could burn and emit embers once the fire
WARNING:Use only your hand to turn the gas key valve.Never use tools. feature is turned.Ensure no person standing close to the fire feature.
If the key valve will not turn by hand,don't try to repair it.Call a qualified 4.Turn on fire feature with remote or power switch.
technician.Force or attempted repair may cause a fire or explosion.
WARNING:Wind and gusty conditions will affect the flame in an unpredictable Sequence of Operation during Ignition
manner.If conditions exist that are not safe for patrons-turn the fire pit off.
• Power is applied.
WARNING:Do not use fire pit if any part has been submerged under • For 24V Premium System-Hot Surface Igniter/Glow Plug becomes
water.Immediately call a qualified service technician to inspect the fire pit. hot and 4-5 seconds later the Pilot Gas Valve opens.
WARNING:Never use any material for media that is non-porous and • For 3 Volt Battery Operated System&24V Standard System-Spark
holds moisture such as gravel,pebbles,river rock,etc.This material,when Igniter will spark repeatedly and 4 5 seconds later the Pilot Gas
heated will cause the trapped moisture to boil,fracture unexpectedly and/ Valve will open.
or explode and cause personal injury or damage.
WARNING:If lava rock is wet,allow fire pit to burn for 45 minutes prior to • Within 10 seconds of power application Pilot Flame should be light
ed and visible.(Visible at night only.)
coming within 15 feet of the fire pit. •
WARNING:Solid fuels shall not be burned in the fire pit.Leaves,sticks, Within 10 seconds of Pilot Flame Ignition CROSSFIRETM Brass Burner
wood,paper,clothing,food material,should be kept away from the fire pit. should ignite.
Make sure that there is no vegetation or other objects over the top or sides
of the fire pit that could interfere with safe operation.If there is any ques- TO TURN OFF ELECTRONIC IGNITION GAS APPLIANCE
tions as to clearances,refer to fit pit clearances in your owner's instructions 1.Turn off power to fire feature-which,in turn,will turn off fire fea-
manualfor specific clearance allowances. ture-this can be done with remote control or switch.
WARNING:When fire pit is not in operation turn off gas valve. 2.Carefully verify flame is OUT.
WARNING:For electronic ignition systems-power supply must be turned 3.Turn off key valve to cut gas off manually per Manual Light instructions.
off to fire pit when not in operation.
WARRANTY REQUIREMENT:When not in use,fire feature must be cov 4. If using LP bottle/tank-turn bottle/tank to CLOSED position
ered at all times.Failure to cover the fire feature will void the warranty. 5.After allowing for ample cooling time,cover the fire feature with
water proof/weather proof cover.
WARNING:If fire feature fails to turn off completely(small flames
LIGHTING INSTRUCTIONS FOR: still visible),turn off gas supply using the manual gas shutoff.
Match Light/Manual Light(no electronics)/Push Button Ignition
1. STOP!Read all the safety information and warnings in the owner's
manual before attempting to light fire feature. MAINTENANCE
1. Prior to turning appliance on visually inspect fire feature to ensure WARNING:Any guard or protective device removed for servicing must be
debris such as leaves or other combustible material has not collect- replaced priorto operating the fire pit
ed inside the feature which could burn and emit embers once the WARNING:Installation and repair should be done by a qualified technician.Fire
fire feature is turned.Ensure no person is standing close to the fire pits should be inspected priorto each use and inspected at least once annually
feature. by a qualified gas appliance service professional.
2.Turn key valve clockwise slightly and then turn counterclockwise WARNING:Ensure gas and power(if applicable)are shut off and fire pit is cool
to the OFF position. before servicing.
2.Wait(5)minutes to clear out any gas.Then smell for gas. Keep fire pit covered at all times when not in use.
3. If you smell gas,STOP! Keep any debris out of fire pit-clean as needed.If debris is found,remove before
4.Shut off gas to appliance. lighting system.
5. Extinguish any open flame. In some areas of the country,spiders or insects have been known to build nests
b. If gas odor continues,keep away from appliance and immediately and/or lay eggs in the gas orifices at the bottom of the jets.This can cause fuel
call gas supplier or fire department. to fill the fire feature cavity and result in personal injury or property damage.
Periodical inspection by a qualified service technician of the air-intake is required
7. If you do not smell gas,turn key valve slowly counterclockwise to to ensure your fire feature performs properly.
the ON position while igniting lighter simultaneously to ignite gas. CROSSFIRE''Jet Orifice Cleaning:Once a year,if flames exhibit any abnormal
8. For Push Button:Press push button ignition and listen for clicking noise shapes or behavior,or if burnerfails to ignite properly,then the burner holes
which indicates electrode is firing.Gas should ignite after a few clicks. located in bottom of gas jet orifices may require cleaning.The appliance can be
WARNING: If the flame will not stay lit after several tries,turn the key valve cleaned by carefully removing the logs and media to allow access to burner.Use
a brush to carefully remove dust,spider webs and loose particles.Use a wire or
to the OFF position and call your service technician or gas supplier.
puncture tool and carefully insert in jet Tool should be size of a small paper clip.
If evidence of damage,burner must be replaced with the appropriate CROSS-
TO TURN OFF GAS APPLIANCE FIRE"bumerspecified by manufacturer.
1.Turn key valve clockwise until it stops. Thermocouple Cleaning of Soot Every six months or as needed.-l�4move
2.Carefully verify flame is OUT. rock&glass around pilot,then the wind cage(screen aroundthkpilot): k'
thermocouple of any soot using soft brush.Be careful notto damage the hot wire
3. If using LP bottle/tank-turn bottle/tank to CLOSED position element.Place lava rock or glass back as explained in the Section rO4ia/r /2 018
4.After allowing for amply cooling time,cover the fire feature with tion in Owners Installation Manual.
6 water proof/weather proof cover. Visual inspection of pilot and pilot assembly:The pilot assembly should bAfaenEN
or
BUILDING DEPARTMENT
and clear of any debris,dust,spider webs and loose particles from the media and by the unit,as well as inconvenience expenses,material or labor charges incurred by
logs.Once pilot assembly is clean,inspect to see flame that covers 3/8"to 1/2"of any service call,repair,removal or re-installation of any unit
the thermocouple.Cleaning of pilot gas orifice may be required by removing pilot Incidental or consequential damages are not covered by this warranty.All burners
hood(CCW)and removing orifice and cleaning out orifices from debris,soot or must be covered when not in use or warranty is null and void.All instructions must be
anything that may be preventing good gas flow from exiting the pilot gas orifice. followed or warranty is null and void.Warranty does not cover damage to systems
Push Button Only:Visually inspect electrode and jet used for conductivity regularly due to debris in the gas lines or damage to system due to water.Owner is responsible
to make sure it is free of debris and soot.Soot build up or obstructions of any kind for reading and TMderstanding warrantyforfull terms and conditions
can reduce effectiveness of spark.Without a strong spark,burner will not light.If Warming Trends ,at its discretion,agrees to repair or replace defective product if re
spark is not strong enough,clean off/remove any soot from jet and,using fine turned to Warming TrendsT within the warranty period.The respective warranty time
grit sand paper,gently remove any rust from electrode.If spark is still not strong periods are effective from the original date of purchase.The warranty is non transfer-
enough to light burner,check/replace batteries.If new batteries don'tfixthe able and applies onlyto the original purchaser.In addition,this warranty is automat-
problem,replace spark electrode.(See glossary for replacement part number.) cally void tithe units serial number has been removed or altered in anyway.
Warranty coverage:
TROUBLESHOOTING-MANUAL LIT/PUSH BUTTON CROSSFIRETM Burners&Aluminum Plates/Pans-Lifetime Warranty
Ready-to-Finish Kits-Limited Warranty
Below are some potential causes and countermeasures to the symptoms listed: - Electronic Ignition Systems-Limited Warranty
No flame Electronic Ignition Systems Warranty Specifications through Warming Trends:
• Make sure the key valve is on.Turn key counterclockwise to open valve and 24VIKand 3V1K Systems are warranted fortwo(2)years;six(6)months for commercial
allow gas flow. projects from date of purchase.As part of the two-year warranty,in the event a system
has to be replaced due to a defect/malfunction of the system,Warming TrendsTM will
Low or Weak Flame repairthe system or replace the system at no cost for the first year and will repairthe
• Verify correct gas pressure. system or replace the system for a 50%discount of purchase price the second year
One or more jets will not light. (personal projects only.)As part of the six month warranty,in the eventa system has to
• Check jets for obstruction. be replaced due to a defect/malfunction of the system,Warming TrendsTM will repair
the system or replace the system for a discount of 50%of purchase price(commercial
Fire feature is making a whistling sound. projects only.)Problems in the functioning of the systems due to gas plumbing or
• Make sure thatthe flex line is the correct size and that there are no kinks in the line. electrical installed by others are not covered under this warranty.No dealer,distributor,
Contacta certified gastechnidanforservicm&repair&these suggestions do notsolvethe issue. or other person has the authorityto represent or warrant a Warming TrendsTm prod-
uct beyond the terms contained within this warranty,and Warming TrendsTM assumes
TROUBLESHOOTING-ELECTRONIC IGNON SYSTEMS no liability for such warranty representations.Any questions concerning this warranty
Below are some potential causes and countermeasures to the symptoms below. should be directed to
tM e Warming Trends corporate office.
Any Warming Trends product deemed by Warming TrendsTM as defective and
No Pilot Flame(Pilot sparks or glow plug glows but pilot won't light) covered by the warranty as stated in the Limited Warranty and Lifetime Warranty may
• Air is in the gas line.Ifthis is a new install it maytake several attempts to purge the air. be returned to Warming Trends for assessment to determine if repair or replacement
• Debris is in the gas line.Clear the gas line. is necessary.In order to return a product,you must have a Retum MerchandiseAu-
• Water/Moisture is in the gas line.Clear the gas line. thorization number(RMA#).Please contacta Warming TrendsTM representative at the
• Incorrect Gas pressure.Confirm proper gas pressure. corporate office to obtain an RMA#.
• Pilot gas orifice is dirty.Remove the pilot head and clean. All retumed merchandise must have the RMA#clearly printed on the outside of the
• Electrical current is not strong enough to support igniter-either spark on package.Return shipping costs are the purchaser's responsibility.
spark igniter isn't strong enough to ignite pilot flame(3V or Standard 24V)or Warming TrendsTM is not responsible for product damaged or lost in transit It is
glow plug is not getting hot enough to ignite pilot flame(Premium 24V). recommended that return items are shipped via a delivery service that can be tracked
• Improperly applied media. and/or insured to confirm receipt
• Wind conditions might be too severe. All custom project sales are final and not eligible for return or credit
No Main Burner(Pilot Lights but main burner will not light) EXAMPLE OF SERIAL NUMBER LABELS(Example only-actual
• Gas pressure is incorrect.Confirm proper gas pressure. label may vary)
• Small pilot flame.Remove the pilot head and clean pilot gas orifice. Certified
• Dirty thermal sensor.Clean using soft brush.
• CROSSFIRETM BURNER has an obstruction.Confirm there is no debris block- Warming Trends—4731 S Santa Fe Cr#2,Englewood,CO 80110
ing gas orifice jets in main burner,purge water and air from gas lines or in the
Medal No:CES601p is
burner,confirm there is no debris in gas lines. sow H•:t 20516t P203675 `FS1
rM
Main Burner Turning On and Off Intermittently
• Small pilot flame.Remove the pilot head and clean orifice. ❑❑lnput 60.000 ITU/OAR yout 180,000 BTU/HR Input❑u lnp,t6250.000 ITU/HR ❑Input:350,000 BTU/MR
• Improperly applied media.See the Section"Media". Qp Min-Ma.Gas Supply 11-.13"WC ONG Min-Max Gas Supply:45--11.5"W.0
• Gas pressure is incorrect.Confirm proper gas pressure. QI Min.Max Gas Supply- tr-14•WC [SIG Min-Ma.Gas Supply:3.5--14-W.C.
• Thermal sensor is dirty ordefective. thermal
Clean theal sensor. Q
Orchan ethe pilot assembly. Qp Min Ma.Gas Supply: 8 13-W-C ❑HG Mon-Max Gas Supply:♦5'-10'W
'J g i� Y pMin Max Gas Supply:ll 13"WC I PIG Min-Ma:Gas Supply:I.S--10-YIIC.C.
• Wind conditions might be too severe.
F.r►Idt_u..u.Ir I,i. �c. ,. AnWulpm 0w..mad taoa cAma•ammo.
Irmo N,.d rtY r.....a.v,r...Wdlapm
Fire Feature is Making a Whistling Sound
• Make sure that the flex line is the correct size and that there are no kinks or �� allt. wawa*awn.*,w,
armingTrends �.____ �.�a... 0
tight bends in the line. ��1—.�••• - -«•CI
A.ma.WS Se md,.mpo.YIWw4M
If replacement parts are required-contact your authorized dealer for authorized re- ManufacturerotrheCROSSFIRE-Braual.ne. w•�'�RYI.I.MI�o...«.....�.,..s
placement parts.Using unauthorized parts may cause damage to the unit and/orcause
catastrophic failure of the unit Warranty is null and void if unauthorized parts are used. Non-Certified
Please contact your retailer or certified technician for service&repair if these Warming Wends-•4731 S Santa Fe Or 42,Englewood,CO 80110
suggestions do not solve the issue. B6.dal Nee CROUP
Serial Hx120516LP203675
WARRANTY ❑Input 60000 BTU/HR ❑Ip..t 65,000 BTU/HR []Input 120.000 BTU/HR
Warming TrendsTM warrants its products to be free from defective material and work- ❑glut 180,000 BTU/HR °Input 250.000 BTU/HR ❑Input 350,000 BTU/HR
manship under normal service and use.This warranty covers manufacturing defects Qp Mon Max Gas Suppy:11'43"WC COG Min-Ma.Gas Supply:45-11.5'W.C.
only and does not cover defects due to normal wear and tear;it does not warrant any Qp Min.Max Gas soppy: r-14'11rC DIG Min Max Gas Supply 3.5"-14"W.C.
Q►Min Ma.Gas Supply: r-tr W.0 ❑HG Mon
-Mon-Max Gas sup ]Fi\ ,y E I)
product or partthat has been altered,accidentally damaged,damaged in shipping, Q►Min Max Gas Supply:ir-ir W.0 NG Min-Ma.Gas Sup \,"S// r fi/1
disassembled,modified,misused,neglected,failure to maintain,not installed,or not ,,, „wn. ra...ol�.....nm Only I am d.dsn O.Iwa oi: :+...
kept in continuous service after installation.Warming TrendsTM liability shall be restrict- "'''w,Agn
""m "'""—"� "•' /
ed to the purchase price of the product only and makes no other warranty,express or A -� amaerra�.� �'fJ{'; 018
implied,but not limited to,the implied warranties of salability and appropriateness for armtngTr1nds .a1101a,M.me MO.. I.I
anraw•rlr.o.11*Con,aro
a specified purpose,with respect to its products and parts,whether used along or in ""Ca s Iky,�..
Manuracturtr or tht H.' FIRE a,at,Ekener '"•a''^�"s'�''l"'Oiro• A i LTV
combination with others.Warming TrendsTM is free of liability for any damages caused 7
BUILDING DEPARTMENT
RETM
BRASSCROSSFI
BURNERS
Manufactured by
larmiiigTrends'
• Select key valve location on your fire pit.
• Plumb your existing gas supply into one side of your key valve.
• Position your preferred support materials for the burner& plate inside of your fire pit(i.e., cinder blocks, elbow
brackets, etc.)
• Warming Trends recommends a 4" clearance from the finished top of your fire pit(capstones)to your plate.
• For Match Lit burners,Warming TrendsT"' recommends a minimum 6" clearance below plate for
additional connections.
• For Electronic Ignition burners,Warming TrendsTM recommends a minimum of 16" -20" clearance below plate
for additional connections.
• Use thread sealant that is resistant to all gases on all fittings except flared fitting to flex line connections.
• Be sure to tighten every joint securely. Use thread sealant where required.
• Perform leak tests on all fittings before turning on ignition.
60K - 120K BTU System with FLKV12
Original Series: CFB60, CFB84,CFB120 I Linear Series: CFBL90,CFBL110 I H-Style Series: CFBH120
Any custom burners between 60K- 120K
FOR PUSH BUTTON IGNITION INSTRUCTIONS: Follow Match Lit System installation instructions.When finished,turn
to page 25 for Push Button Ignition installation instructions.
STEP 1 : Locate FLKV12
Parts include /"flex line, key valve and keys(4 and 12 inch.)
Ewa
4"Key Pressure Key Valve
Face Plate
„nn
imam
iii
12"Key Flex Line
RECEIVED
04/20/2018
8 60K-120K BTU System with FLKV12 ASPEN
BUILDING DEPARTMENT
STEP 2: Remove /"flared fittings from ,—\
each end of 12"flex line. —'IIIIIINIUIII
Flex Line
Flared Fitting
iliiiii......_
, IIIII1IIIIII
STEP 3A: (FOR MATCH LIT SYSTEM)
Connect one of your/"flared fittings removed in
Step 2 to the coupling located on the bottom
of the aluminum plate with flared end on bottom. Coupling
Tighten.
STEP 3B:(3 VOLT IGNITION) _ _
Coupling I
Apply thread
sealant here
-I!
Plate t Plate
Flared
Fitting Flared Fitting `
lill4
u
1- 111111E11D
3 Volt Ignition Apply thread
sealant here
Drip Leg
STEP 3C:(STANDARD 24 VOLT IGNITION)
Coupling
Plate
Flared
Fitting
r
1— IIIIII110
Apply thread
Standard 24 Volt sealant here
Drip Leg Ignition
STEP 3D:(PREMIUM 24 VOLT IGNITION)
Coupling
Plate
Flared
il
Fitting
1- 111111■111111
Apply thread
RECEIVED
Premium 24 Volt sealant here 0 4 2 0 2 018
Drip Leg Ignition ����pp�������
60K-120K BTU System wA1-P?IW 2 9
BUILDING DEPARTMENT
STEP 4A: (MATCH LIT SYSTEM) ,
Connect the ' "flex line to the fitting now located
on the bottom of your aluminum plate. Coupling
STEP 4B:(3 VOLT IGNITION)
Plate
Coupling
/Flared Fitting
PlateI I ____ .____
II �iiIiiiiii I-I IIIII
3 Volt Flared Flex Line
Dri Le Ignition Fitting
p g Flex Line
STEP 4C:(STANDARD 24 VOLT IGNITION)
Coupling
Plate
Standard Flared Flex Line
Drip Leg 24 Volt Fitting
Ignition
STEP 4D:(PREMIUM 24 VOLT IGNITION)
IICoupling
Plate
1•
.11111. 1IIIII11114—ii IIIIII
Flared Flex Line
Drip Leg Premium Fitting
24 Volt
Ignition
STEP 5: Locate the other'/2"flared fitting removed Key Valve
in Step 2 and connect into the1" key valve, placing Flared Fitting
the non-flared end into the key valve.Tighten.. (
( -*
/
Apply thread
sealant here RECEIVED
, , 04/20/2018
10 60K-120K BTU System with FLKV12 ASPEN
BUILDING DEPARTMENT
FINAL SETUP
Coupling
STEP 6A: (MATCH LIT SYSTEM)Connect'/2"flex line into the _ _
fitting connected in Step 5 to key valve.Tighten. Flared
Fitting
STEP 6B:(3 VOLT IGNITION)
Coupling i
Plate
3 Volt Gas Valve _\
Plate Flex Line
Flared
Drip Leg Fittings
Key Valve
Gas Line In —
Flex Line
Key In
mm
STEP 6C:(STANDARD 24 VOLT IGNITION) i
Coupling /
41 \
Standard 24 Volt Ignition Z
itPlate Flared
1 Fitting
J Key In
r,
Drip Leg Flared Fittings
U Fittings Key Valve
Key Valve
Gas Line In—
1 II
\Flex Line
C7
KeyIn-
c�,
Gas Line In
STEP 6D:(PREMIUM 24 VOLT IGNITION)
Coupling
Premium 24 Volt Ignition
----1- p _ _
Plate
, • ,
04
Flared
Drip Leg Fittings
Key Valve
Gas Line In—■MOAN 0 STEP 7:(STANDARD 24 VOLT AND PREMIUM 24 VOLT
IGNITION SYSTEMS ONLY) � ����
n Flex Line Plug ignition into three prong,above gra
Key In outdoor specific GFCI electrical outlet or have electrician
= hardwire ignition into transformer. 04/20/2018
Questions? Contact Warming Trends at 303.346.2224 60K-120K BTU System w{tTFPLIfb"T2 11
BUILDING DEPARTMENT
121 K - 249K BTU Systems with
FLKV34 and FLKV34FIT180
Original Series: CFB180 I Linear Series: CFBL130,CFBL150,CFBL190,CFBL210 I H-Style Series: CFBH160,CFBH200,
CFBH240 Any custom burners between 121 K-249K
FOR PUSH BUTTON IGNITION INSTRUCTIONS: Follow Match Lit System installation instructions.When finished,turn
to page 25 for Push Button Ignition installation instructions.
STEP 1 : Locate FLKV34
Parts include 3/a"flex line, key valve and keys(4 and 12 inch)
and FIT180.
!1.1!
•=. 1/1
4"Key
Pressure Key Valve
�1 Face Plate
'EIIIEIIIIII
�J 12"Key Flex Line
FIT180:1/2"x 2"Nipple
STEP 2: Remove 3/a"flared fittings from — 1
each end of 3/4"flex line. J 111111E111111
Flex Line
I I/
3/4"Flare Fitting
iiiii iiiiiI
STEP 3: Connect your FIT180 fitting to 3/4"Flare Fitting
the inside threads of one of the 3/4"flared Apply thread sealant here
fittings removed in Step 3. NI
-,
ECEIVED
1 "x 2" Nipple(FIT180) Use inside threads
of flared fitting 0 4/2 0/2 018
1 2 121K-249K BTU Systems with FLKV34 and FLKV34FIT180 ASPEN
BUILDING DEPARTMENT
STEP 4A: (MATCH LIT SYSTEM)Connect the
new fitting created in Step 4 to the 1"coupling located on
the bottom of the aluminum plate.Tighten.
Coupling
STEP 4B:(STANDARD 24 VOLT IGNITION)
Coupling
Standard 24 Volt Ignition
Apply thread -
sealant here Apply thread
1"x 2"Nipple sealant here
Plate (FIT180)
T. ~01111111111111111111111111_r Plate
Flared Fitting
Drip Leg 1"x 2" Nipple(FIT180) Flared Fitting L
STEP 4C:(PREMIUM 24 VOLT IGNITION)
Coupling
Premium 24 Volt Ignition
Plate Apply thread sealant here
4— IIIdI•IIIii1111111Niiiii1
.w
Flared Fitting
Drip Leg 1"x 2" Nipple(FIT180)
STEP 5A: (MATCH LIT SYSTEM) Connect
3/4"flex line to the fitting now located on the bottom of the Coupling
aluminum plate. - r
'h"x 2"Nipple
STEP 5B:(STANDARD 24 VOLT IGNITION) (FIT180)
• Coupling
Standard 24 Volt Ignition Flared Fitting
1"x 2"Nipple
(FIT180)
Platelir I.
IIIIIIIIII!IIIII
r i
Flared Fitting Flex Line
Drip Leg Flex Line T
STEP 5C:(PREMIUM 24 VOLT IGNITION)
Coupling
Premium 24 Volt Ignition
' ' x 2"Nipple
(FIT180)
Plate
; 0 4-:IIIIIIIII RECEIVED
Flared Fitting Flex Line 0 4/2 0/2 018
Drip Leg nneepp AA''�
121K-249K BTU Systems with FLKV34 and FLK 4F 1 3
BUILDING DEPARTMENT
STEP 6: Locate the other 3/4"flared fittingKey Valve
Flared Fitting
removed in Step 3 and connect into the 3/4" key / /
valve.Tighten using crescent wrench. —I
\ \
LI Apply thread J
sealant here
Li
FINAL SET UP
STEP 7A: MATCH LIT SYSTEM Connect 3/4"flex line into Plate
the fitting connected in Step 7.Tighten. Coupling
F
STEP 7B:(STANDARD 24 VOLT IGNITION) x 2"Nipple(FIT180)
I
Coupling Flared
Standard 24 Volt Ignition _ Fitting
1/z"x 2"Nipple ---____--
(FIT180) Plate
I11111111111111111111111111111111114i
�j Flex Line I
Flared o
Drip Leg FittingsMI
y Valv
Gas Line In—: i 1:11111111111111IIIIIIII11�\
Flex Line
Key In
STEP 7C:(PREMIUM 24 VOLT IGNITION)
Coupling
Standard 24 Volt Ignition
1/z"x 2"Nipple Tfl
Plate
MI Flared 1
Fitting
Flared I
Drip Leg Fittings Key In
Key Valve 0
Gas In— L Key Valve
gFlex Line L
Key In
= U U
Gas In
STEP 8: (STANDARD 24 VOLT AND PREMIUM 24 VOLT IGNITION SYSTEMS ONLY) RECEI ED
Plug ignition into three prong,above grade, NEMA Rated, outdoor specific GFCI electrical outlet or have electrician
hardwire ignition into transformer. 04/20/ 018
14 121K-249K BTU Systems with FLKV34 and FLKV34FIT180 Questions? Contact Warming Trends at 303.346. Nl`+
BUILDING DEPARTMENT
250K - 299K BTU Match Lit System with
DFLKV34 and DFLKV34FIT250
Original Series: CFB250, CFB290 I Linear Series: CFBL250, CFBL270
Any custom burners between 250K-299K
NOTE: If using the Standard 24 Volt High Capacity Ignition,turn to page 25 for instruction on installation.Burners
between 250K-300K BTU's using a Standard 24 Volt Ignition will need to use the FIT300.Turn to page 20 for installation
instructions.
FOR PUSH BUTTON IGNITION INSTRUCTIONS: Follow Match Lit System installation instructions.When finished,turn
to page 25 for Push Button Ignition installation instructions.
STEP 1 : Locate DFLKV34 and FIT250
Parts include two 3/4"flex lines, key valve and keys
(4"and 12") plus FIT250 Kit.
COD D
1
4"Key
Pressure Key Valve
„Th Face Plate
/1 I.IIIIIIIIIII
12"Key
SI
FIT250:(1)3/4"x 3"Nipple,(1)3/4"x'/2"MM Reducer Fitting, (2)3/4"Tees
/I I.IIII.IIIIII
Flex Lines
RECEIVED
04/�� pp
2ee0/2018
250K-299K BTU Systems with DFLKV34 and DFLK�J4F1ab 15
BUILDING DEPARTMENT
STEP 2: Remove 3/4"flared fittings from each Flared Fitting
end of 3/4"flex lines. ■�
IIIIIIYIIIIII I—
Flared Fitting
I■
11111111111111
Flared Fitting
■R /
IIIIIIEIIIIII I—
\ —
Flared Fitting
ME
fi 111111E111111
STEP 3A: Connect 12"x 3/4" reducing fitting
to the ' "coupling located underneath the
aluminum plate. Coupling
STEP 3B:(STANDARD 24 VOLT
HIGH CAPACITY IGNITION)
1/2"X 3" r
Reducing
Fitting(FIT250) Apply thread sealant here
SEE PAGE 20 FOR
INSTALLATION
INSTRUCTION
Plate
STEP 3C:(PREMIUM 24 VOLT STANDARD CAPACITY IGNITION)
1/2"x Ye
Coupling Reducing
Fitting(FIT250)
Plate
Apply thread
sealant here
Drip Leg Premium
24 Volt
Standard
Capacity
Ignition
RECEIVED
04/20/2018
16 250K-299K BTU Systems with DFLKV34 and DFLKV34FIT250 ASPEN
BUILDING DEPARTMENT
STEP 4A: Connect one 3/4"tee fitting to the
connection made in Step 3 (1/2"x 3/4" reducing
fitting to the ' "coupling under aluminum pan.) Coupling
STEP 4B:(STANDARD 24 VOLT HIGH CAPACITY IGNITION) 1/2"x 3/a"
Reducing — —
Fitting(FIT250)
SEE PAGE 20 FOR
INSTALLATION
INSTRUCTION Apply thread sealant here
Plate
STEP 4C:(PREMIUM 24 VOLT STANDARD CAPACITY IGNITION)
•
3/4"Tee(FIT250)
Coupling
Plate 1.1111
IIIIIInllll�l 3/4"Tee
(FIT250)
Drip Leg Premium Apply thread
24 Volt sealant here
Standard
Capacity 'h"x 3A"Reducing
Ignition Fitting(FIT250)
STEP 5A: Connect two of the 3/4"flared fittings
removed in Step 2 to tee fitting now located
underneath aluminum plate. Coupling
STEP 5B:(STANDARD 24 VOLT HIGH CAPACITY IGNITION)
Plate
1"x 3/4"Reducing
SEE PAGE 20 FOR Fitting(FIT250)
INSTALLATION Flared FittingC _ ) Flared Fitting
iiiiii•iiiiii — ~ 111111E111111
/
Apply thread Apply thread
STEP 5C:(PREMIUM 24 VOLT STANDARD CAPACITY IGNITION) sealant here 3A"Tee(FIT250) sealant here
' "x 3A" Flared Fitting
Coupling II Reducing Apply thread
Fitting(FIT250) sealant here
MI
Plate r• III�111111~� 3/4"Tee
1 (FIT250)
Drip Leg Premium r Apply thread RECEIVED
24 Voltma= sealant here RECEIVED
Standard
Capacity I I Flared Fitting 0 4 2 0 2 018
Ignition
250K-299K BTU Systems with DFLKV34 and DFLKVWP-I 250 1 7
BUILDING DEPARTMENT
STEP 6A: Connect both 3/4"flex lines to the 3/4"flared
fittings connected in Step 5.Tighten.
STEP 6B:(STANDARD 24 VOLT HIGH CAPACITY IGNITION) Coupling
1,2'x 3/4"
Reducing - -
Fitting(FIT250)
SEE PAGE 20 FOR
INSTALLATION
INSTRUCTION c D
'L S \
/ ) 4—
/ / \
Flex Line Flex Line
3/4"Tee(FIT250)
STEP 6C:(PREMIUM 24 VOLT STANDARD CAPACITY IGNITION) Flared Fitting Flared Fitting
[H Flex Line
lh"x 3/4"
Reducing
Nir
Coupling i Fitting(FIT250)- Flared
I.
Fitting
■ Cliff3/4"Tee
PlateIII
(FIT250)
Flared
Drip Leg
1!.
. Fitting
Premium 24 Volt Standard I
Capacity Ignition r i
I Flex Line
STEP 7A: Connect 3/4"x 3" pipe nipple \
(FIT250)to the 3/4" key valve. —I Key Valve
STEP 7B:(STANDARD 24 VOLT IGNITION) - /
Same as above.
STEP 7C:(PREMIUM 24 VOLT IGNITION)
Same as above. 3"x 3A" Apply thread
Pipe Nipple sealant here
(FIT250) u
STEP 8: Connect remaining 3/4"tee fitting Apply thread Key Valve
(FIT250)to the connection made in Step 7. sealant here
STEP 8B:(STANDARD 24 VOLT IGNITION) /
3/a"Tee —I
Same as above using FIT300. (FIT250)
STEP 8C:(PREMIUM 24 VOLT IGNITION) \
Same as above using FIT250. 3"x 3/4"
Pipe Nipple
(FIT250)
u
STEP 9: Connect remaining 3/4"flared fittings to Flared Fitting
the 3/4"tee fitting connection made in Step 8.
STEP 9B:(STANDARD 24 VOLT IGNITION) Apply thread sealant here
Same as above. 1
Key Valve
STEP 9C:(PREMIUM 24 VOLT IGNITION)
Same as above. 3A"Tee(FIT250)
r P„ RECEIVED
Pipee Nipple
Apply thread sealant here (FIT250)
Flared Fitting 04/20/2018
1 8 250K-299K BTU Systems with DFLKV34 and DFLKV34FIT250 ASPEN
BUILDING DEPARTMENT
FINAL SET UP
Coupling
STEP 1 OA: Connect _
available ends of 3/4"
flex lines(connected to 1"x 3/4"Reducing Fitting(FIT250) —1 Plate
aluminum plate in Step
6)to 3/4"flared fittings ,i- -L-
connected in Step 10.
$* gIIIIIiIlIIIIIIII1i—,( \ , �!11111111111111111I11101/
Flex Line Flex Line 01.2
Flared 3/4"Tee Flared
Fitting (FIT250) Fitting
STEP 10B:HIGH CAPACITY IGNITION)VOLT 411111 . IN M �11111.10110
_ 11```
11111111111111111_ 111111_ IIII.IIIIIl IIIIIIIIIIIIIIIIIIIIII
SEE PAGE 20 FOR 3"x 3/4"Pipe Nipple(FIT250)
INSTALLATION
INSTRUCTION IEI
U Key In •
111111i1'
Key Valve
-I
STEP 10C:(PREMIUM 24 VOLT STANDARD CAPACITY IGNITION) Gas In
Flex Line f
Coupling
INIIMP
1 II1
Flared Fitting MI '!j Flared
3/4"Tee = ' = Fitting
Key Valve (FIT250) IIII
11111111111
Gas In—•U.IIII■■IIII 3/4"Tee
MM. 3"x 3/4" — (FIT250)
Nipple — Drip Leg Premium 1N'
(FIT250) 1■1 24 Volt Standard Flared
Standard Fitting
Flared = Capacity I
Fitting T Ignition MI
��� NM
/z"x 3/4"
Key In Fitting(FIT250)
Flex Line
c
lOUP//IIIII� 111111I111IIIIID� �
STEP 11:(STANDARD 24 VOLT AND PREMIUM 24 VOLT IGNITION SYSTEMS ONLY) RED �V ""'b
Plug ignition into three prong,above grade, NEMA Rated, outdoor specific GFCI electrical outlet orl� lec ave etrician
hardwire ignition into transformer. 04/20/2018
Questions? Contact Warming Trends at 303.346.2224 250K-299K BTU Systems with DFLKV34 and DFLK994FI IN) 19
BUILDING DEPARTMENT
300K+ BTU Match Lit System with
DFLKV34 and DFLKV34FIT300
Original Series: CFB300,CFB350,CFB450 I H-Style Series: CFBH300, CFBH340
Any custom burners 300K and above
FOR PUSH BUTTON IGNITION INSTRUCTIONS: Follow Match Lit System installation instructions.When finished,turn
to page 25 for Push Button Ignition installation instructions.
STEP 1 : Locate DFLKV34 and FIT300 \
Parts include two 3/a"flex lines, key valve and keys
(4"and 12") plus FIT300 Kit.
0 O 11.11
���
4"Key
Pressure Key Valve
rFace Plate
u 12"Key
I!iiiiiiiiiii
\ i
FIT300:(2)3/a"x 3" Nipples,(2)3/4"Tees
111111E1111H
Flex Lines
RECEIVED
04/20/2018
20 300K+BTU Systems with DFLKV34 and DFLKV34FIT300 ASPEN
BUILDING DEPARTMENT
STEP 2: Remove 3/4"flared fittings from each Flared Fitting
end of 3/4"flex lines. ■K
IIIIIIYIIIIII 4-
Flared Fitting
mm
Flared Fitting IIIIIIEIIIIIII
IIIIIIIIIIIIII4-i1IIOIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIi
£IIIllhIIOUIOhIIIIIIlIIIIIOIIIIIIHOII 'Fla red Fitting
mm
iiOIIIIOIIIOhIIOIIlIIIIIIIIIIIIII! 1111111111111
STEP 3A: Connect 3/4"x 3" pipe nipple
fitting to the coupling located underneath
Coupling
the aluminum plate.
- I Apply thread sealant here
Plate
3/4"x 3" Nipple(FIT300)
STEP 3B:(STANDARD 24 VOLT IGNITION) STEP 3C:(PREMIUM 24 VOLT IGNITION)
Coupling —Coupling
3/4"x 3"Nipple(FIT300) Plate 3/4"x 3"Nipple(FIT300)
Plate
Apply thread Apply thread
Standard sealant here Standard sealant here
Drip Leg 24 Volt Drip Leg 24 Volt
Ignition Ignition
RECEIVED
04/2CC0pp/2018
300K+BTU Systems with DFLKV34 and DFLKnn 4 TBR) 21
BUILDING DEPARTMENT
STEP 4A: Connect one 3/4"tee fittings to the '
connection made in Step 3 (3/4"x 3" pipe nipple
under aluminum pan.) Coupling
3/4"x 3"Nipple(FIT300)
Plate Apply thread
♦ sealant here
3/a"Tee(FIT300)
STEP 4B:(STANDARD 24 VOLT IGNITION) STEP 4C:(PREMIUM 24 VOLT IGNITION)
Coupling 3/4"x 3" Coupling— 3/a"x 3"
Nipple Nipple
(FIT300) (FIT300)
Plate T 4— Plate
4—
Apply thread Apply thread
Drip Standard sealant here s/a"Tee(FIT300) Drip Premium sealant here 3/a"Tee(FIT300)
Leg 24 Volt Leg 24 Volt
Ignition Ignition
STEP SA: Connect two of the 3/4"flared fittings
removed in Step 2 to tee fitting now located underneath Coupling
aluminum plate.
Plate
3/a"x 3" Nipple(FIT300)
Flared Flared
Fitting Fitting
EnIIIIII■vIIiiii 1111E111111
w
Apply thread 3/a Tee(FIT300) Apply thread
sealant here sealant here
STEP 5B:(STANDARD 24 VOLT IGNITION) STEP 5C:(PREMIUM 24 VOLT IGNITION)
Flared Fitting Flared Fitting
Standard 1.1 Premium inCoupling 111 24 Volt = Apply thread pPYI thread Coupling— 24 Volt - A
Ignition Ignition
1 sealant here 1 sealant here
ir
Plate it IIIIAIIIII 3/a"Tee(FIT300) Plate 3/4"Tee(FIT300)
D
3/a"x 3" Drip 3A"x 3"
Drip Nipple I Leg Nipple
Leg (FIT300) - Apply thread (FIT300) _ p' rI V E D
1.1 sealant here i•i alant.�►r
Flared Fitting Fl6Al) r0/2018
22 300K+BTU Systems with DFLKV34 and DFLKV34FIT300 ASPEN
BUILDING DEPARTMENT
Coupling
STEP 6A: Connect both 3/4"flex lines to the 3/4"flared
fittings connected in Step 5.Tighten with crescent wrench. 3/4"x 3"
Nipple
(FIT300)
Plate
Flared Fitting Flared Fitting
Flex Line C - -) Flex Line
1 v / / --L s
/~
U
3/4"Tee(FIT300)
STEP 6B:(STANDARD 24 VOLT IGNITION) STEP 6C:(PREMIUM 24 VOLT IGNITION)
L J Flex I Flex
Standard Line Premium Line
24 Volt 1 24 Volt 1
Coupling 11 Ignition ==
== Coupling , Ignition
I!j Flared Fitting I!! Flared Fitting
ma
Plate — Plate
�� 3/a"Tee(FIT300) I I lll� 3/a"Tee(FIT300)
ma
Drip 3/a"x 3" 1�I g. Flared Fitting Drip 3/a"x 3" I•! Flared Fitting
Nipple Leg Nipple =
(FIT300) = (FIT300)
I I
jFlex I L_Flex
Line I I Line
I
STEP 7: Connect 3/4"x 3" pipe nipple(FIT300) 3/a"x 3"Nipple(FIT300) Key Valve
to the 3/4" key valve.
L__[ 1
Apply thread
sealant here
u
STEP 8: Connect remaining 3/4"tee fitting 3/a"x 3" Nipole(FIT300) Key Valve
(FIT300)to the connection made in Step 7.
3/a"Tee(FIT300)
L I
Apply thread
sealant here
u
STEP 9: Connect remaining 3/4"flared fittings Flared Fitting
to the 3/4"tee fitting connection made in Step 8.
Apply thread
1 sealant here
3/a"x 3"Nipple(FIT300)
3/4"Tee(FIT300) Key Valve
T
Apply thread RECEIVED
seal here
I•! Flared Fitting
04/20/2018
300K+BTU Systems with DFLKV34 and DFLK994FI00 23
BUILDING DEPARTMENT
FINAL SET UP Coupling
STEP 10A: Connect Plate
available ends of 3/4"
flex lines(connected to 3Aa"x 3" Pipe Nipple(FIT300)
aluminum plate in Step
connected in Step 0. IIIIIIIIIIIIIIIIIII'.� ` �.
������ Illlllllllllllllllllpp/f
Flared 3/a"Tee Flared =_
Fittings (FIT300) Fittings
Raft
mft
144111111111111IIIIII!—' 11111111111 IIII!IIIIII 4—!IIIIIIIIIIIIIIIIIIIIO�w
y "x 3" Pipe Nipple(FIT300) I
iEi
O Key In •
—1IIIIII11 Key Valve
i•i
1
Gas In
STEP 10B:(STANDARD 24 VOLT IGNITION) STEP 10C:(PREMIUM 24 VOLT IGNITION)
Flex Flex
Line Line
Coupling
Coupling
3/a"x 3"
3/a"x3"
Flared 1 Nipple 1 Flared Flared 1 Nipple 1 Flared
Fitting _ Fitting (FIT300)
(FIT300� _ Fitting _ s Fitting
Plate I
Key Valve 1� Plate Key Valve )
�■ IIII•III 3/a"Tee i
IIII 3/a"Tee
1 - (FIT300) rLJ (FIT300)
JL -) Drip Premium I Flared
Gas In DripStandard Flared Gas In
— 3/a"x 3 3/a x 3
[ J Leg 24 Volt Fitting l J Leg 24 Volt Fitting
pple
FIppleIT300) Flared Ignition T (FIT300)NI -- Flared Ignition 1
I Fitting 1■_I
% 1.� T Fitting 1�
= I.
Flex Key In Flex Key In j ////,
Line Line
���������/U//��ll'f'��i���I�IIIIIIII����������``
%%///////////IIIIIIIIIII�IIIIIIIIIIIIIIIDO�p
STEP 11: (STANDARD 24 VOLT AND PREMIUM 24 VOLT IGNITION SYSTEMS ONLY) RECEIVED
Plug ignition into three prong,above grade, NEMA Rated, outdoor specific GFCI electrical outlet or have electrician
hardwire ignition into transformer. 04/20/2018
24 300K+BTU Systems with DFLKV34 and DFLKV34FIT300 Questions? Contact Warming Trends at 303.346N
BUILDING DEPARTMENT
Push Button Ignition Installation
NOTE: If the burner being installed uses a titled jet, use the 3.0" Spark Igniter.If the burner uses a straight jet,use the
3.25" Spark Igniter.
Use the 3.0" Spark Igniter Use the 3.25" Spark Igniter
STEP 1 :To place 125„ "ft......... 125";
Spark Igniter in ---"
proper position,the Tilted Jet Straight
installer will need Jet
to drill a hole in the CROSSFIRE
Brass Burner CROSSFIRE
plate. • • Brass Burner
Measure where to
drill holes by holding
tip of Spark Igniter f
Drill •
Here
no further than .125" Drill Here_X
away from inside
edge of jet. Drill hole Plate Plate
where base of Spark
Igniter sits.
Spark Spark
Igniter Igniter
STEP 2: Place
wires through drilled •
hole and pull through
until Spark Igniter
bracket is in place on •
plate.
1
---------)) Plate
Plate
125
STEP 3: Screw
_125"
Spark Igniter to i
plate. Make sure tip
of Spark Igniter sits
no further than .125"
away from the inside
•
edge of the jet. •
NOTE: If Spark Igniter
is too high when
flush with plate,
run mechanism up T T T T
through bottom of 1 1 1
plate. .)
CEI 9;
Push Butt6FH rrhtiR 25
BUILDING PARTMENT
STEP 4: Install push
button module into
mounting bracket.
Key Valve
1) Unscrew button cover. Push Button /
2) Remove plastic nut. Module
3) Insert washer#1 onto
the button stem.
4) Insert push button
I.;
stem through mounting Mounting
bracket hole. Button Stem =_ Bracket
5) Insert washer#2. washer#1
6) Put on plastic nut and
turn until push button
control has been secured Washer#2
to mounting bracket. Nut L I I
7) Insert AAA battery into
button stem.
8)Screw on button cover. AAA Battery
CT
T
Button Cover (0
Spark Igniter Wires
Key Valve
1
STEP 5: Crimp Spark
Igniter wires,then slide
crimped wires on to
connections using needle Push Button Mounting
nose pliers. Be careful Module Bracket
not to break connectors. J
Wires can go in either
connection.
1
STEP 6: Test Spark Igniter and Push Button Module WITHOUT gas, making sure spark arcs from electricity to jet.
STEP 7: Test with gas. Burner should light within 5 seconds or a few clicks.
RECEIVED
04/20/2018
26 Push Button Ignition ASPEN
BUILDING DEPARTMENT
Parts Glossary
0 1
1 E CoD 11.11
/
; -- --- iiii,i{
'' 12"Key(KEY12) 4"Key(KV12 or KV34) I?
Pressure Face Plate Key Valve
\ — (KV12 or KV34) (KV12 or KV34)
111111■IIIIII
l 00,1Nl/y
111111111111 /ilaiiiIIIUIIUIUIJ4404 4 0YOYYiI4''4Y1J4\\\4:44d4UIIII11IIIIu,IIUWIY�NW V1
/
Flex Line(FL3612 or FL3634) Flared Fitting Flared Fitting
r,
�_
311 (
b
J L J
Push Button Module(PBL-CM)
Spark Igniter(PB-SI)
41° LI \
Mounting Bracket(PBMBR)
RECEIVED
04/20/2018
ASPEN 27
BUILDING DEPARTMENT
Replacement Parts
FLKV12 For use with any burner up to 120K BTU's.Kit Includes:(1)36"Lx 1/"Diameter Flex Line+1/"Key Valve+4"and 12"Key
FLKV34 For use with any 121K-249K BTU Burner.Kit Includes:(1)36"L x3/4"Diameter Flex Line+3/4"Key Valve+4"and 12"Key
FLKV34FIT180 For use with any 121K-249K BTU Burner.Kit Includes:(1)36"Lx3/4"Diameter Flex Line+3/4"Key Valve+4"and 12"Key+1h"x2"Nipple to connectthreaded
inside 3/4"Flex Line Flare Connector to 1/"Plate Coupling
DFLKV34 For use with any burner over 249K BTU's.Kit Includes:(2)36"L x 3/4"Diameter Flex Lines with+Y4"Key Valve+4"and 12"Key
DFLKV34FIT250 For use with any burner over 249K BTU's.Kit Includes:(2)36"L x3/4"Diameter Flex Lines+3/4"Key Valve+4"and 12"Key+(1)34"x1 "MM Reducer Fitting and(1)
3/4"Tee for connection at 1/2"Plate Coupling+(1)3/4"x 3"Nipple and(1)3/4"Tee for Key Valve connection
DFLKV34FIT300 For use with any 300K+BTU Burner.Kit Includes:(2)36"L x3/4"Diameter Flex Lines+3/4"Key Valve+4"and 12"Key+(1)3/4"x3"Nipple and(1)3/4"Tee for
connection at 3/4"Plate Coupling+(1)3/4"Tee for Key Valve connection
FIT180 Flex Line&Key Valve Connection Fitting for use with any burner over 249K BTU's.Kit includes:(1)1 "x 2"Nipple.Connects 1/2"Plate Coupling to inside threaded 3/4"
Flex Line Flare Connector
Flex Line&Key Valve Connection Fittings for 250K-299K BTU Burner.Kit includes:(1)3/4"x 1/2"MM Reducer Fitting and(1)3/4"Tee for connection at 12"Plate
FIT250 Coupling+(1)3A"x 3"Nipple and(1)3/4"Tee for Key Valve connection.Connects 1/2"Plate Coupling to two 3/4"Flex Lines+connection of two 3/4"Flex Lines to 3/4"
Key Valve.
FIT300 Flex Line&Key Valve Connection Fittings for 300k+BTU Burner.Kit includes:(1)3/4"x 3"Nipple and(1)34"Tee for connection at 3/4"Plate Coupling+(1)3A"x 3"
Nipple and(1)3/4"Tee for Key Valve connection.Connects 3/4"Plate Coupling to two 3/4"Flex Lines and two 3A"Flex Lines to 3/4"Key Valve.
FL3612 36"L x 1/2"Diameter Flex Line(MM) FL3634 36"L x'A"Diameter Flex Line(MM)
KV12 1/2"Key Valve+4"Key KV34 3/4"Key Valve+4"Key
KEY12 12"Key KEY24 24"Key
DRIPLEG12 1/2"Drip Leg Kit DRIPLEG34 3/4"Drip Leg Kit
LPRH LP Regulator mounted on 3 "10'Hose with handwheel quick connect.For use up to 125k BTU's.For Use with a 20LB propane tank
LPHOSE10 LP 3r8"10'Hose.For use with a 20LB Propane Tank
REGLPNG125 1/2"FNPT Inletx Y"FNPT Outlet.LP/NG convertible.Up to 125K BTU's
REGLPNG140 1/4"FNPT Inletx FNPT Outlet.LP/NG convertible.Up to 140K BTU's
Ignition Systems
PBIK Push Button Ignition Kit:spark igniter rod and wire+push button battery operated control module
PB-SI Spark igniter rod and wire
PB-CM Push button battery operated control module
PBMBR Mounting Bracket
3VIK-NG/3VIK-LP Full Replacement Kit for 3V Ignition System
3VCM 3V Control Module
3VPA-NG/3VPA-LP 3V Pilot Assembly(pilot tube+igniter+spark wire+igniter bracket+wind cage)
3VGV-NG/3VGV-LP 3V 120K BTU Capacity Gas Valve
Battery Pack 3V Battery Pack
3VSTEP 3V Step Down Transformer
24VIKSC-NG/24VIKSC-LP Full Replacement Kit for Standard 24V Ignition System(Standard Capacity)
24VGVSC-NG/24VGVSC-LP 24V 200K BTU Capacity Gas Valve(Standard Capacity)
24VIKHC-NG/24VIKHC-LP Full Replacement Kit for Standard 24V Ignition System(High Capacity)
24VGVHC-NG/24VGVHC-LP 24V 400K BTU Capacity Gas Valve(High Capacity)
24VCM 24V Control Module for use with Standard Ignition Systems(SC&HC)
24VPA-NG/24VPA-LP 24V Pilot Assembly(pilot tube+igniter+spark wire+igniter bracket+wind cage)for use with Standard Ignition Systems(SC&HC)
Transformer For use with all 24V Ignition Systems(Standard Ignition and Premium Ignition)
P24VIKSC-NG/P24VIKSC-LP Full Replacement Kit for Premium 24V Ignition System(Standard Capacity)
P24VCBSC Premium 24V 290K BTU Capacity Control Box(Standard Capacity)
P24VIKHC-NG/P24VIKHC-LP Full Replacement Kit for Premium 24V Ignition System(High Capacity)
P24VCBHC Premium 24V 512K BTU Capacity Control Box(High Capacity)
P24VIKPA-NG/P24VIKPA-LP Premium 24V Pilot Assembly(pilottube+igniter+spark wire+igniter bracket+wind cage)for use with Premium Ignition E(( EIVED
*,.,
P24VIKWC Wind Cage ``
04/20/2018