HomeMy WebLinkAboutFile Documents.1130 Black Birch Dr.0096.2018 (73).ARBK ENERVEX MFD MECHANICAL FIREPLACE DAMPER 3916100 08.17 Installation & Operating Manual • EMPRO a � READ AND SAVE THESE INSTRUCTIONS! RECEIVED 1685ENERVEX Inc. F:770.587.4731 E N E RV EX[� 18 1685 Bluegrass Lakes F:770.587.4731 Parkway T:800.255.2923 Alpharetta,GA 30004 info@enervex.com VENTING DESIGN SOLUTION S USA www.enervex.com BUILDING DEPARTMENT 3916100 08.17 IMPORTANT: READ THESE INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION. • EXAMINE ALL COMPONENTS FOR POSSIBLE SHIPPING DAMAGE PRIOR TO INSTALLATION. Symbol Legend TO REDUCE THE RISK OF FIRE, ELECTRI- The following terms are used throughout this manual to bring CAL SHOCK OR INJURY TO PERSONS, attention to the presence of potential hazards, or to important OBSERVE THE FOLLOWING: information concerning the product. 1. Use this unit in the manner intended by the manufacturer. DANGER: Indicates an imminent hazardous If you have questions, contact the manufacturer at the situation which, if not avoided, will result in death, address or telephone number listed on the front of the serious injury or substantial property damage. manual. WARNING: Indicates an imminent hazardous 2. Before servicing or cleaning the unit, switch off at service Asituation which, if not avoided, may result in panel and lock service panel to prevent power from being personal injury or property damage. switched on accidentally. 3. Installation work and electrical wiring must be done by a How to use this manual qualified person(s) in accordance with applicable codes This installation manual does not contain any system design and standards. documentation. System design documentation is available from any authorized ENERVEX representative. Accessories, 4. Follow the appliance manufacturer's guidelines and safety fans, and variable frequency drives are not covered by standards such as those published by the National Fire this manual. Please refer to these component's individual Protection Association (NFPA), and the American Society manuals. for Heating, Refrigeration and Air Conditioning Engineers ASHRAE), and the local code authorities. 5. This unit must be grounded. RECEIVED ENERVEX® Li 04/20/2018 VENTING DESIGN SOLUTIONS 2 ASPEN BUILDING DEPARTMENT 3916100 08.17 Content 1. PRODUCT INFORMATION 1.1 Function 4 1.2 Shipping 4 1.3 Warranty 4 1.4 Components 4 2. SPECIFICATIONS AND DIMENSIONS 2.1 Dimensions and Capacities 5 3. MECHANICAL INSTALLATION 3.1 Actuator and Cover 6 3.2 Location 6 4. ELECTRICAL INSTALLATION 4.1 General 7 4.2 Wiring of a Gas Fireplace with a Damper 8 5. STARTUP AND CONFIGURATION 5.1 Set Up 10 5.2 Sequence of Operation 10 6. MAINTENANCE 6.1 Cleaning 10 RECEIVED ENERVE ! 18 3 VENTING DESIGN SOLUTIOAN p BUILDING DEPARTMENT 3916100 08.17 1. PRODUCT INFORMATION 1.1 FUNCTION The ENERVEX MFD is a low profile, automated fireplace damper. It is for use in conjunction with an ENERVEX ADC100 control and RS model chimney fan as part of the EcoDamper System. or with an ADC150 control and and RS model chimney fan as part of the IntelliDraft System. It prevents excess heat from escaping through the chimney when the fireplace is not in use. The MFD is designed for chimney top installations and is for use with gas fireplaces only. The MFD is powered by a 120 or 24 VAC actuator. The actuator is interlocked to the control so it only operates when the fireplace is in use and the fan is running. When there is a call for heat from the fireplace, the ADC100 or ADC150 control begins its operational sequence to open the damper and start the chimney fan. Once the damper opens and there is sufficient draft in the chimney, the control releases the gas valve for fireplace operation. The actuator has two endswitches to prove damper position (open or closed) and is equipped with the Enerdrive fail safe system to open the damper in the event of an electrical or mechanical failure. The damper is rated for temperatures up to 575°F(300°C). The damper is sized to provide sufficient clearance between the damper blade and the fan inlet when open. The MFD is constructed of 18 gauge, type 304 stainless steel. System installation must conform to the requirements of the authority having jurisdiction. When required by the authority having jurisdiction, the installation must also conform to the NFPA31, NFPA54 or NFPA211. All electrical wiring must be in accordance with the requirements of the authority having jurisdiction or, in absence of such requirements, with the National Electric Code, NFPA 70. 1.2 SHIPPING c e Damper, actuator, cover and hardware are shipped as a unit. * If other components are shipped, they will appear as separate items on the packing list. a . 1.3 WARRANTY 2-Year Factory Warranty. Complete warranty conditions are available from ENERVEX, Inc. 1.4 COMPONENTS i41 0 1111, Components of the MFD are listed below: a. Actuator/Acuator Cover b b. Stop Flange c. Fan Adapter d d. Collar e. Damper Blade Fig. 1 RECEIVED ENERVEX® t1 04/20/2018 VENTING DESIGN SOLUTIONS 4 ASPEN BUILDING DEPARTMENT 3916100 08.17 2. SPECIFICATIONS AND DIMENSIONS 2.1 DIMENSIONS AND CAPACITIES Fan Model RS009 and RS012 Chimney Size 6" 8" 10" 11" 12" 13" 14" 16" in 5.87 7.87 9.87 10.87 11.87 12.87 13.87 15.87 0 A mm 149 200 251 276 302 327 352 403 in 15.60 15.60 15.60 15.60 15.60 15.60 15.60 19.70 BxB mm 396 396 396 396 396 396 396 500 Dimensions in 15.75 16.75 17.75 18.25 18.75 19.25 19.75 22.80 C mm 400 425 451 463 476 489 502 579 in 2.11 2.27 2.44 2.52 2.61 2.69 2.77 2.94 D mm 54 58 62 64 66 68 70 75 Fan Model RS014 and RS016 Chimney Size 8" 10" 11" 12" 13" 1 14" 16" 18" 20" in 7.87 9.87 10.87 11.87 12.87 13.87 15.87 17.87 19.87 0A mm 200 251 276 302 327 352 403 454 505 in 19.70 19.70 19.70 19.70 19.70 19.70 19.70 23.30 24.50 BxB mm 500 500 500 500 500 500 500 592 622 Dimensions in 18.80 19.80 20.30 20.80 21.30 21.80 22.80 25.60 27.20 C - - - - mm 477 503 516 528 541 554 579 650 691 in 2.27 2.44 2.52 2.61 2.69 2.77 2.94 3.11 3.27 D mm 58 62 64 66 68 70 75 79 83 B , I 1 1 II , Gil T_- } 1 L_ -J 45 i_l_ L 95-1 Dom{ h_ I ' L it, f 6,5 I.-OA { RECEIVED ENERVE ! 18 5 VENTING DESIGN SOLUTIOAN p BUILDING DEPARTMENT 3916100 08.17 3. MECHANICAL INSTALLATION 3.1 ACTUATOR AND COVER Before installing the MFD on the chimney, a power cable SHEET METAL SCREWS-\ should be wired to the actuator(See Ch. and the (2)ON TOP SIDE 4) actuator (4)ON BOTTOM SIDE cover should be secured. Use 4-conductor cable(min. 18 AWG)with a weatherproof jacket such as rubber or silicone. Install a weatherproof cable connector on the side of the actuator cover to prevent water iii 0 a��1� ingress to the actuator. Use(6) of the included sheet metal screws to secure the actuator cover to the MFD. Once secure, apply a bead of silicone around the seams of the cover. CABLE CONNECTOR Fig. 2 3.2 LOCATION Mount the MFD outdoors at the top of a steel chimney. Slide RS FAN the collar of the MFD into the steel chimney until the damper 111110 rests on the stop flange. Sheet metal screws may be installed around the collar into the chimney for additional support. Once the MFD is secured, place the RS fan on the adapter. ;c Use the mounting holes on the fan base as a drill template to make one mounting hole in each corner of the adapter. I MFD Use bolts and locking nuts to secure the fan to the MFD. 12.1110 STEEL CHIMNEY Fig. 3 RECEIVED ENERVEX® 9 04/20/2018 VENTING DESIGN SOLUTIONS 6 ASPEN BUILDING DEPARTMENT 3916100 08.17 4. ELECTRICAL INSTALLATION 4.1 GENERAL 0 DANGER 120 VAC Turn off electrical power before servicing. N L1 I-1 Neutral Contact with live electric components can cause H L2—0.—I—2 Hot shock or death. Verify voltage of actuator before connecting On/Off wiring for TFX120 S Ato a power supply. Acuator will run on either 120VAC or 24VAC. Wire that actuator for 2 wire/2 position operation as shown I s1 in Fig. 4 (120 VAC)and Fig. 5 (24 VAC) below. . III S2 NO The actuator should be set for clockwise(CW) rotation I Il S3 NO 0°to 95° and should fail to 90°(MFD will open). Verify settings of the actuator before wiring. On/Off wiring for TFX120-S Fig. 4 120 VAC Actuator 24 VAC Transformer 4 - I- 1 Common — — 0—I—2 +Hot On/Off wiring for TFX24-S ^ s1 1 S2 NC I S3 NO 0°to 95° On/Off wiring for TFX24-S Fig. 5 24 VACNDC Actuator RECEIVED ENERVidk° 18 7 VENTING DESIGN SOLUTIOAtrr^ BUILDING DEPARTMENT 3916100 08.17 4.2 WIRING OF A GAS FIREPLACE WITH A DAMPER Complete system wiring details are shown in the ADC100 The MFD must be interlocked to an ENERVEX control. and ADC150 Control Installation Manuals. When used with a gas fireplace as part of the EcoDamper System, both a RS Chimney Fan and MFD will interlock with the ADC100 control as shown in Fig.6. When used with an IntelliDraft System, the RS Chimney Fan and MFD will interlock with an ADC150 control as shown in Fig. 7. Power to the actuator must be supplied externally. Interlock the damper with the control board via terminals 14 and 15 as shown below and on the next page. The Normally Open and Common terminals of the actuator endswitches should connect to the damper prove terminals(16 and 17). FAN MOTOR S al L N N L a x � O O O 5' 0 _ 7 V - n O X I / ON n O p q 7 I I ADC100 AC IN FAN OUT 24VDC AUIN2 AUIN 1IXTP SEN 9 PD5 IN RELAY I PROVEI RELAY I CTRL OUT2 AOUT1 24 2 1 2 3 4 5 6 7 8 0 0 9 10 0 0 0 11 12 13 14 15 16 17 18 19 20 21 0 0 22 23 000 000 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I III II I I I I I I L I J — I I r I I I I I I I I I I I I I I I i 1 I I i I I I I I I I I I I I L1 N L ti� POWER SUPPLY WALL SWITCH 1 z 120 VAC OR RECEIVER 0 0 0 L Must Be Dedicated J NOI NCI PDS-1 IFireplace L---- o L1 I I GAS VALVE $N I GENERATOR • I I — I I I I I HOT COM I I II TH TR O 00I 0 N L1 Si 53 DAMPER GAS VALVE ACTUATOR OR IGNITION Fig. 6 REC NVE ENERVEX® t1 04/20/2018 VENTING DESIGN SOLUTIONS 8 ASPEN BUILDING DEPARTMENT 3916100 08.17 FAN MOTOR ca x � � n O O. a CO O o x / / m n c 3 7 q q 7 I I C ADC 150 1 AUX 2 AUX I XTP DAMPER VFD AUX 2 AUX 1 AC IN FAN OUT 24VDC IN IN PDS IN RELAY I PROVE RELAY'CTRL OUT OUT 24 25 26 27 28 _ 29 30 1 2 3 4 5 6 7 8 0 0 9 10 0 0 0 11 12 13 14 15 16 17 18 19 20 21 0 0 22 23 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 III I I I I I L--J - I I I I L r� I I I I i i i ♦ �F I I I I I I I Li N L C POWER SUPPLY SWITCH 1 z 120 VACC OR OR RECENER L J L J Must Be Dedicated I I 0 ° III vnvow I I I Appliance EXHAUST N> I I I L---- XTP $Lt GAS VALVE N GENERATOR I I I HOT COM 0000 TH TR N LI 51 53 DAM PER GAS VALVE ACTUATOR OR IGNITION Fig. 7 RECEIVED ENERVE ! 18 9 VENTING DESIGN SOLUTIcAt ^rr BUILDING DEPARTMENT 3916100 08.17 5. STARTUP AND CONFIGURATION 5.1 SET-UP Once the MFD has been installed, verify operation and rotation of the damper.The end of the damper rod is notched to indicate position of the damper blade. As the actuator opens the damper, the notch will indicate movement from 0 to 90° in the clockwise (CW) direction. If the damper does not operate correctly when power is supplied or if it rotates the wrong direction, verify wiring as shown in Ch. 4 of this manual. 5.2 SEQUENCE OF OPERATION See Ch. 5 of the ADC100 Control Installation Manual for the sequence of operation of the EcoDamper System. See Ch. 5 of the ADC150 Control Installation Manual for the sequence of operation of the IntelliDraft System. 6. MAINTENANCE AND TROUBLESHOOTING 6.1 CLEANING Clean the MFD periodically at the same time the fan and/or chimney are cleaned. Damper should be cleaned with a cloth or rag. Check for and remove any debris that may be blocking the damper opening or chimney. RECEIVED ENERVEX® t1 04/20/2018 VENTING DESIGN SOLUTIONS 10 ASPEN BUILDING DEPARTMENT 3916100 08.17 Notes -RECEIVED ENERVidk° 18 11 VENTING DESIGN SOLUTIANV BUILDING�rj DEPARTMENT 0 0 0 0 co RECEIVED 1685 BEX Inc. F:770.587.4731 E N E RV EX[� 18 1685 Bluegrass Lakes F:770.587.4731 Parkway T:800.255.2923 Alpharetta,GA 30004 info@enervex.com VENTING DESIGN SOLUTION USA www.enervex.com L BUILDING DEPARTMENT