HomeMy WebLinkAboutFile Documents.905 Chatfield Rd.0111.2018 (164).ARBK KNIGHT BOILER DIMENSIONS AND SPECIFICATIONS c _e-- HIGH VOLTAGE LOW VOLTAGE ELECTRICAL _ am ELECTRICAL CONNECTIONS L CONNECTIONS ~ M -� N I FLUE 1 DRAIN ��C INLET L [• D 0 4t H K to A E F A eat L COIN VENT �,� 111 OUTLET v H TOP AIR VENT RIGHT t 'I BOTTOM B 11_ KNIGHT BOILER 1.1111kE5TIFIED` DIMENSIONS AND SPECIFICATIONS Input Heating Net AHRI Model Max. Min. AFUE% Capacity Rating A B C D E F G H I I K L M N 0 Gas Water Air Vent Shipping Number MBH MBH MBH MBH MBH Conn. Conn. Inlet Size Wt.(lbs. WHNO56 55 8.3 95 51 44 33-1/4"18-1/2" 16" 11-3/4" 9" 3-1/2" 3-3/4" 1-1/2" 3" 6-1/8" 7-1/4" 3-3/4"6-1/2 4-1/2" 8-1/2" 1/2" 1" 2" 2" 139 WHNO86 85 8.5 95 79 69 33-1/4"18-1/2" 16" 11-3/4" 9" 3-1/2" 3-3/4" 1-1/2" 3" 6-1/8" 7-1/4" 3-3/4"8-1m41/2" 8-1/2" 1/Y' 1" 2" 2" 142 WHN111 110 11 95 102 89 33-1/4"18-1/2" 19" 14-1/2" 8-3/2" 5" 7-3/4" 1-1/8" 12-3/8" 4-1/4" 11-1/4" 3" 5-1/4"5-1/8" 10" 1/Y' 1" 3" 3" 159 WHN156 155 15.5 95 144 125 33-1/4"18-1/2" 19" 141/2' 8-1/2" 5" 7-3/4" 1-1/8" 12-3/8" 4/14" 11-1/4" 3" 5-1/4"5-1/8" 10" 1/2" 1" 3" 3" 166 WHN200 199.9 19.9 95 185 161 33-1/4"18-1/Y' 19" 14-1/2" 11" 6-1/4" 7-3/4" 1-1/Y' 12-3/8" 4-1/4" 9-1/2" 3" 5-1/4"5-1/2" 10-3/4"1/2" 1-1/4" 3" 3" 175 WHN286 285 28.5 264 229 33-1/4"18-1/2" 21-3/4"16-1/2" 11-1/8" 6-1/4" 7-3/4" 1-1/2" 12-3/8" 16-3/8" 12-1/4" 3-1/8" 5-1/4"4" 15-1/8"1/2" 1-1/4" 3" 3" 184 WHN400 399 80 94.4* 377# 328 35-1/2"25" 21-3/4"17-1/2" 12-1/2" 9-1/4" 9-1/2" 2-1/4" 13-1/4" 21-1/2" 9" 4-3/4" 4" 22-1/2"3-3/4" 3/4" 1-1/2" 4" 4" 213 *Thermal Efficiency% #Gross Output MBH **10:1 Turndown ratio and top and bottom water connections are not included on WHN400.WHN400 operates with a 5:1 turndown. Information subject to change without notice.Change"N"to"L"for LP gas models. The Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15.Lochinvar should be consulted before selecting a boiler for installations having unusual piping and pickup requirements,such as intermittent system operation,extensive piping systems,etc.The ratings have been determined under the provisions governing forced draft burners. SMART SYSTEM FEATURES STANDARD FEATURES >Smart System Digital Operating Control >Access to BMS Settings through Graphic LCD Display >95 DOE AFUE Efficiency(56-286) Multi-Color Graphic LCD Display w/Navigation Dial, >High-Voltage Terminal Strip S Modulating Burner with up to 10:1 Turndown** Soft Keys and Loch-N-Link USB programming 120 VAC/60 Hertz/1 Phase Power Supply Direct Spark Ignition >Three Boiler Setpoint Temperature Inputs Three Sets of Pump Contacts Low NOx Operation Plus Domestic Hot Water Prioritization >Low-Voltage Terminal Strip >ASME Stainless Steel Heat Exchanger >Built-in Cascading Sequencer for up to 8 Boilers, DHW Recirculation Pump Start/Stop 30 PSI ASME Relief Valve with Cascade Redundancy 24 VAC Device Relay >Top and bottom water connections(MNPT)** Multiple Size Boiler Cascade Proving Switch Contacts Lead Lag Flow Switch Contacts >Vertical&Horizontal Direct Vent Efficiency Optimization Alarm on Any Failure Contacts PVC,CPVC,Polypropylene or SS Venting up to 100 feet Front End Loading Capability Runtime Contacts >SMART SYSTEM Control >Outdoor Reset Control with Outdoor Air Sensor DHW Thermostat Contacts >Condensate Trap Programmable for Three Reset Temperature Inputs 3 Space Heat Thermostat Contacts >Other Features >Programmable System Efficiency Optimizers System Sensor Contacts Automatic Reset High Limit SH Night Setback DHW Tank Sensor Contacts Adjustable High Limit w/Manual Reset DHW Night Setback Outdoor Air Sensor Contacts Boiler Circulating Pump Anti-Cycling Cascade Contacts Zero Clearances to Combustible Materials Outdoor Air Reset Curve 0-10 VDC BMS External Control Contact Ramp Delay 0-10 VDC Boiler Rate Output Contacts 15-Year Limited Warranty(See Warranty for Details) Modulation Factor Control 0-10 VDC Variable Speed System Pump Signal Input 5-Year Limited Parts Warranty Boost Temperature&Time 0-10 VDC Signal to Control Variable Speed Boiler Pump OPTIONAL EQUIPMENT >Four Pump Control Modbus Contacts System Pump with Parameter for Continuous Operation >lime Clock CON-X•US Remote Connectivity Boiler Pump with Variable Speed Control >Data Logging Modbus Communication Domestic Hot Water Pump Hours Running,Space Heating BACnet MSTP Domestic Hot Water Recirculation Hours Running,Domestic Hot Water Flow Switch >Domestic Hot Water Prioritization Ignition Attempts Low-Water Cutoff w/Manual Reset&Test DHW tank piped with priority in the boiler loop Last 10 Lockouts Alarm Bell DHW tank piped as a zone in the system with the pumps >Maintenance Reminder Concentric Vent Kit controlled by the SMART SYSTEM Custom Maintenance Reminder with Condensate Neutralization Kit DHW Modulation Limiting Contractor Contact Information BMS Gateway to LON or BACnet IP Separately Adjustable Space Heat/DHW Switching Times Installer Ability to De-activate Service Reminder Multi-Temperature Loop Control >Building Management System Integration >Low-Water Flow Safety Control&Indication Sidewall Vent Termination 0-10 VDC Input to Control Modulation or Setpoint >Password Security Wireless Outdoor Sensor 0-10 VDC Modulation Rate Output LP Gas Conversion Kit 0-10 VDC Input to Enable/Disable Call for Heat >Customizable Freeze Protection Parameters >Firing Codes M9 Standard Construction **Not included on WHN400 M7 California Code • Lochinvar,LLC ■ ,�"' 300 Maddox Simpson Parkway _ 11 Lebanon,Tennessee 37090 7,'')' (fill; r+- e 1 �.� Ci� P:615.B89.8900/F:615.547.1000 I ENCY BOILERS&WATER HEATERS 19©®0 Lochinvar.com CERTIFIr"® � 2 WHN-05 (Reprint WHN-05 6/17) ©Lochinvar,LLC- ASB-10M 10/17-Printed in U.S.A. iPhone and iPod touch are trademarks of Apple Inc.,registered in the U.S.and other countries. Android and Google are trademarks of Google Inc.,registered in the U.S.and other countries. App Store is a service mark of Apple Inc.Google Play is a service mark of Google Inc.