HomeMy WebLinkAboutFile Documents.121 E Hyman Ave.0008-2019-BCHO (11) INSTALLER/CONSUMER RETAIN THIS APPLIANCE MANUAL WITH THE INSTALLED APPLIANCE GB INSTALLATION AND OPERATING INSTRUCTIONS FS GOLDEN BLOUNT US MODELS LFP4218/LFP6018/LFP7218 TOP VENT GAS FIREPLACE PFS APPROVED FOR NATURAL GAS OR PROPANE GAS IMPORTANT! Read all instructions carefully before starting installation. Failure to follow these instructions may result in property damage, personal injury or possible loss of life. • The Flue Damper must be in the WARNING: If the information in these full open position when operating instructions is not followed exactly, a this appliance. fire or explosion may result causing property damage, personal injury or • This fireplace is to be burned only death. with the material supplied with the fireplace. Burning other items could — Do not store or use gasoline or cause a fire hazard or injury. other flammable vapors and liquids • For best results, Natural Gas pressure in the vicinity of this or any other should be 7" to 12" W.C. and 11 " W.C. appliance. for Propane Gas. — WHAT TO DO IF YOU SMELL GAS: • Check the label on the firebox to •Do not try to light any appliance. assure the proper gas type. Never use anything but the correct gas •Do not touch any electrical switch; type for your fireplace. do not use any phone in your building; •Immediately call your gas supplier This appliance complies with National from a neighbor's phone. Follow the Safety and is tested and listed to ANSI gas supplier's instructions. Z21.50 - 2014 as Vented Gas fireplaces. •If you cannot reach your gas Installation must conform to local codes. supplier, call the fire department. In the absence of local codes, installation must conform with the current National — Installation and service must be Fuel Gas Code, ANSI Z223.1 . performed by a qualified installer, service agency or the gas supplier. If your plans do not allow for the venting system as outlined previously in the"installing chimney/vent system"section,you may contact ENERVEX, Inc.(formerly EXHAUSTO)at 800-255-2923. They will design an approved venting system to suit your venting MANUFACTURED BY: needs.These power vented systems follow the standards and codes Pined under the NFPA 54/ANSI Nation Fuel Gas Code. Please having with the local authority jurisdiction in your area. The engineers at ENERVEX are familiar with Golden Blount 4301 WESTGROVE DRIVE fireplaces and their systems will allow you to minimize the amo vent pipe exposed outside of your home.Fireplace rn,�tafio l ED ADDISON TX. 75001 horizontally vented with these systems. ii /nR/ 019 10/17 ASPEN BUILDING DEPARTMENT TABLE OF CONTENTS Section Layout Options 2 Identification of Parts 3-4 Building Codes and Safety Standards 5 Piping and Gas Pressure Requirements 6 Installation Instructions 7-10 Glass Installation / Flame Stabilizer Installation 10-12 Operating Guidelines 12 Maintenance Instructions/Wiring Diagram 13 Lighting Instructions 14-15 Trouble Shooting 16-17 Replacement Parts 18 INSTALLATION OPTIONS Si INSIDE 0 FLUSH MOUNT CHASE ROOM 0 t"., CORNER MOUNT A X A B C LFP4218TV 61" 86.5" 44" LFP6018TV 85" 117.5" 61.5" Figure 2.1 LFP7218TV 89.75" 127" 72"RE�EIVE 11/08/2019 2 ASPEN BUILDING DEPARTMENT LFP4218 TOP-VENT FIREPLACE _ f Outside Air / Connection INTERIOR VIEW Stand Off Stand Off Damper Control Lever Burner + • Pilot Assy/ Flame Sensor a On/Off Switch Outside Air Control Knob Valve AccessDEr F l E D 11/08 019 3 ASPEN BUILDING DEPARTMENT LFP6018/7218 TOP-VENT FIREPLACES .1%. k * , i ( i LEFT 1 g RIGHT OUTSIDE AIR CONNECTIONS INTERIOR VIEW Damper Control Lever Pilot Assy/ Flame Sensor Right Outside Air Control Left Outside Air Control On/Off Switch "Fr) .)Y fr f;- J, Valve Access DocOr 11/08/ 019 4 ASPEN BUILDING DEPARTMENT BUILDING CODES AND SAFETY STANDARDS The design of this FIREPLACE has been tested and is listed with PFS CORPORATION in accordance with THE AMERICAN NATIONAL STANDARDS INSTITUTE — ANSI Z21 .50-2014. This manual serves only as a basic guideline for installation and use of this firebox and gas piping. The complete installation must be in accordance with local codes and ordinances, or, in the absence of local codes, with the American National Standards Institute National Fuel Gas Code Z223.1 latest edition. GENERAL INFORMATION MODELS LFP4218,6018 & 7218 ARE TOP VENTED GAS FIREPLACES. THEY ARE DESIGNED TO BURN BY DRAWING COMBUSTION AIR FROM THE OUTSIDE AIR KIT THAT ATTACHES TO THE SIDE (SIDES) OF THE FIREPLACE. THE EXHAUST FLUE GASES ARE TO BE VENTED THROUGH THE TOP-VENT USING 8" OR 10" B-TYPE GAS VENT PIPE. THE CONTROL SYSTEM IS A (3V) SPARK TO PILOT TYPE THAT INCLUDES A ON-OFF SHUTOFF VALVE, A GAS CONTROL VALVE, A SPARK TO PILOT LIGHT ASSEMBLY, AND ON-OFF ROCKER SWITCH. WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL. NOTE: INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT THE UNITS CONTROL COMPARTMENT, BURNERS, AND CIRCULATING AIR PASSAGE-WAYS BE KEPT CLEAN TO PROVIDE ADEQUATE COMBUSTION AND VENTILATION AIR. CLEARANCES REQUIRED MINIMUM CLEARANCES FOR THE FIREBOX ARE: 1/2" ON THE SIDES AND BACK AND 0 AT THE BOTTOM. TOP CLEARANCE IS 3" WHICH IS THE HEIGHT OF TOP STANDOFFS, (LFP4218), 3" (LFP6018/7218). NOTE: PROVIDE ADEQUATE CLEARANCES AROUND AIR OPENINGS INTO THE COMBUSTION CHAMBER. NOTE: ADEQUATE ACCESSIBILITY CLEARANCES FOR SERVICING AND PROPER OPERATION MUST BE PROVIDED IN ACCORDANCE WITH ANSI Z21.50-2014RECEIVE 11/08/2019 5 ASPEN BUILDING DEPARTMENT GAS PIPING AND GAS PRESSURE REQUIREMENTS All gas piping must be installed to comply with local codes, or, in the absence of local codes, with the latest edition of the National Fuel Gas Code ANSI Z223.1. Unions in gas lines shall be of ground joint type. Compounds used on threaded joints of gas piping must be resistant to the action of liquefied petroleum gas. Gas piping must be of sufficient size to provide a minimum natural gas pressure at the appliance of 7" water column or 11 " for L.P. gases for the purpose of input adjustment. The maximum inlet gas pressure to the unit must not exceed 10" for natural gas, and 13" for L.P. gases. If this unit is to be supplied with L.P. gas (bottled propane) the tank or bottle supplying the gas must have a regulator that reduces the gas pressure to between 11 and 13 inches water column. The control will not operate with gas line pressure directly from the tank and may leak gas due to this excessive pressure. DANGER: OPERATION OF THIS UNIT ON L.P. GAS WITHOUT AN APPROVED REGULATOR AT THE SUPPLY CONTAINER WILL LEAD TO GAS LEAKS AT THE CONTROL WITH POSSIBLE FIRE OR EXPLOSION. Include a manual shut-off valve and union in the line so the control or heater may be disconnected for servicing. Include a drip leg and a plugged 1/8" N.P.T. tapping into the line also. The tapping must be accessible for the test gauge connection immediately upstream of the gas supply connection to the unit. Use a soap and water solution or liquid gas leak detector to coat each joint in the piping system and look for bubbles which indicate gas leaks. Repair all gas leaks. CAUTION: THE APPLIANCE AND ITS APPLIANCE MAIN GAS VALVE MUST BE DISCONNECTED FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY PRESSURE TESTING OF THAT SYSTEM AT TEST PRESSURES IN EXCESS OF 1/2 PSI (3.5 KPA). THE APPLIANCE MUST BE ISOLATED FROM THE GAS SUPPLY PIPING SYSTEM BY CLOSING THE EQUIPMENT SHUTOFF VALVE DURING ANY PRESSURE TESTING OF THE GAS SUPPLY PIPING SYSTEM AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSI (3.5 KPA). DANGER: DO NOT USE CANDLES, MATCHES OR OTHER IGNITION SOURCES WHEN CHECKING FOR LEAKS. FUEL GASES ARE VERY FLAMMABLE AND IN CERTAIN CONCENTRATIONS, EXPLOSIVE. CHECKING FOR LEAKS WITH AN OPEN FLAME MAY LEAD TO FIRE OR EXPLOSION. RECEIVED 11/08/2019 6 ASPEN BUILDING DEPARTMENT INSTALLATION INSTRUCTIONS In planning the installation for the fireplace it is necessary to determine where the unit is to be installed, the routing of the B-type vent system, and whether optional accessories are to be used gas supply piping should also be planned. Models LFP4218,6018 & 7218 (with the use of the Outside Air Kit ) can be installed in a bedroc (in the United States) which has a total volume of unconfined space appropriate to the particular installation. Refer to the National Fuel Gas Code ANSI Z223.1/NFPA 54 - (current edition), the Uniform Mechanical Code - (current edition), and Local Building Officials for the options allowed in obtaining an effective bedroom volume of unconfined space. The fireplace can be mounted on any of the following surfaces: 1. A flat combustible surface. 2. A raised wooden platform. 3. Four (4) corner supports. (Example: four (4) concrete masonry blocks.) These supports must be positioned so they contact all four corner edges on the bottom of the unit. If the fireplace is installed directly on carpeting, tile, or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the unit. Fireplace framing can be built before or after the fireplace is set in place. Framing should be positioned to accommodate wall covering and fireplace facing material. The fireplace framing should be constructed of 2 x 4 lumber or heavier. The framing headers may rest on the fireplace standoffs. Refer to Figure 8.1 for fireplace and framing reference dimensions. CAUTION: VERIFY FIREPLACE DIMENSIONS, FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING CONSTRUCTION BEGINS. Determine the exact position of the fireplace so that the vent run can be planned. Figure 2.1 shows possible locations for the fireplace; inside of a room, flush mount in a chase, or installed in a corner. Using a level, make sure the fireplace is properly positioned and squared. WARNING: DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES. CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE. Please note: B-Vent appliances are not designed to operate in negatively pressured environments (pressure within the home is less than pressure outside). Significant negatively pressured environments caused by weather, home design or other devices may impact the operation of this appliance. Negative pressures my result in poor flame;CEIVE appearance, sooting, damage to property and/or severe personal injury. Do not operate' this appliance in negatively pressured environments. 11/08/2019 7 ASPEN BUILDING DEPARTMENT MINIMUM FRAMING DIMENSIONS LFP4218 I ('' ice- 31 TOP VIEW -- UNIT DIMENSIONS FOR 44 \ I 0 0 1/2" CONSTRUCTION PLANNING `I 231, /2" S FRONT VIE 1411 ` A, i 4" SIDE VIEW 36" 6"l' } �\ 35" El I 1 ""c•-. 52" OPENING MINIMUM ..1. 24" HEIGHT FRAMING 7" DIMENSIONS `\ ( I \ 2.5" • 42, _� J 6.5 FRONT OF ,� Figure 8.1 51" o APPLIANCE HOLE FOR GAS LINE MIN. FRAMING DIMENSIONS LFP6018/7218 LFP6018/7218 LINEAR TOP VENT ROUGH FRAMING DIMENSIONS MINIMUM FRAMING DIMENSIONS PRIOR TO POSITIONING UNIT 11/1‘1 TOP LFP6018 75"W X 52"H X 24" D all[112" VIEW LFP7218 87"W X 52"H X 24" D FINISHED FRAMING DIMENSIONS WITH UNIT IN POSITION LFP6018 70"W X 32"H X 24"D LFP7218 82"W X 32"H X 24"D NOTE:DIMENSIONS PRIOR TO POSITIONING FIREPLACE ALLOWS CLEARANCE FOR OUTSIDE AIR COLLARS AS WELL AS FIREPLACE HEADER TO BE NAILED AT CORRECT HEIGHT AFTER BOX HAS BEEN SET. 18 7/8" AININP OOP' 4•Mnp I I- I . INSTALLED AFTER III FIREPLACE IS 1 41/8" • POSITIONED ` 4„= . A4 1. 11811/16 " INSTALLED AFTER 11111/11.11111 FIREPLACE IS - /IIIIIEII29" POSITIONED 52" CT) 32" 7„i 2 1/2" MINIMUM + O} FRAMING t6, 24" I. D .1 - 231/2" DIMENSIONS ,'` LFP 6018 LFP7218 6 1/2" -.1".....„. g A 70" 82" B 75" 87" Figure 8.1 C 60" 72" Installing Chimney/Vent System D 68 3/4" 80 3/4" Models LFP4218,6018 & 7218 are approved to be used with 8" or 10" B-Type Gas Vent. Under most conditions the fireplace system will draw properly if the chimney height is determined in accordance with the following guidelines: Note: (90-degree elbows are not approved! Maximum offset angle must not exceed 45 degrees.)Many manufacturers of B-Type gas vent offer "High Performance," or "High Wind" caps. These caps limit the outlet area for flue gasses to expel and should not be used with this fireplace. In the event of draft related problems due to extreme wind conditions, a special wind ring is available. 1. If your chimney penetrates the roof within 10' of its peak, it must be extended at least 24" above your roof's peak and be at least 36" above the highest point of the roof opening, (see below). 2. If the chimney penetrates the roof farther than 10' from its peak, measure from the centerline of the chimney t roc a point 10' away, between the chimney and the peak of the roof.The top of the chimney must be at least 36 IL!I V L.IV above the highest point of the roof opening,(see below). 11/0 8/2 019 8 ASPEN BUILDING DEPARTMENT Installing ChimneyNent System Continued 3. The 10' Rule of Thumb is a guide for calculating chimney height that works under most conditions. However, many factors can cause the need for additional chimney height beyond what 10' Rule of Thumb would indicate. Topographical factors can cause high-pressure zones,which prevent a chimney from drawing.This can occur if the house is located in a low-lying area, in a valley or near the base of a cliff or hillside.The same situation can occur if the chimney is near other steep rooflines or tall buildings.Areas with high winds also frequently require higher than normal chimneys. Certain styles of architecture tend to interfere with a fireplace's draw. If the room in which the fireplace is located has a very high ceiling,smoke may enter the room unless the chimney is terminated at a level higher than that of the ceiling,even if the 10' Rule of Thumb indicates a shorter chimney height. Note: Installations which will not allow the 10' rule to be followed must be submitted to Golden Blount Inc.for approval. 1-800-833-1139. Warning! This gas appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. Note: A draft hood is installed and is in the same atmospheric pressure zone as the combustion air inlet to the appliance and is located so that the relief opening is accessible for checking vent operation. less than MORE THAN 10' 10' 7'min. 2'min. \G t 3'min. 00. 10' Installing Outside Air Kit Models LFP4218/6018 are supplied with the component parts for outside combustion with the exception of the 4" flex duct. It is recommended that the outside air system be used whenever possible. Connect 4" Class-1 Flex duct or Metal Vent to duct collar on side of firebox, run duct to fresh air source and terminate using duct termination cap. The Outside air can be opened by pulling control knob toward front of fireplace and closed by pushing towards rear(Refer to figure 9.1). NOTE: Model LFP6018 supplied with two duct collars, one on each side. DUCT OUTER TERMINATION;' FP CDUCTG \�� I / RAIN CAP I \ LEFT SIDE LFP4218 COLLAR \ CONTROL LEFT AND RIGHT TWO �® � ' ' .L 4/: LFP6018 SUPPLIED CAULKING WITH LFP6018 WALL . I Figure 9.1 Connecting the Gas Line Consult local building codes before gas line installation. This gas fireplace is designed to accept a 3/8" male flare fitting attached to a 1/2" supply line. Have the gas line installed by a qualified service person in accordance with all building codes. Install gas line to fireplace on the right side attaching gas line to the gas flex line inside the control box accessed by opening the control box door. RECEIVED 11/08/2019 9 ASPEN BUILDING DEPARTMENT STUD 2X4 HEADER Finishing the Wall FINISHED WALL Finish the wall with the material of your choice. Do not install a combustible mantle or other NON-COMBUSTIBLE combustible projection above the SEAL JOINT fireplace opening unless it is a minimum of 12 inches above top MANTLE -\ of fireplace opening. (Figure 10.1) -{-- 12" MIN ." TOP OF OPENING • Figure 10.1 CAUTION: All joints between the finished wall and the fireplace surround (Top and Sides) can only be sealed with non-combustible material. Only non-combustible material can be applied as facing to the fireplace surround. (Figure 10.1) Hearth Extension A Hearth Extension may be installed. But it is not required for vented gas fireplaces. GLASS INSTALLATION (optional) 1. All LFP MODELS can be used with approved Fireglass to enhance the overall appearance. 2. Fill the burner tray below and up to the top of the burner ports. Do not cover burner ports. 3. Distribute additional glass around front, sides and rear of burner tray, covering floor area. (Figures 10.2-11.1) :or•" ` 4.. 8!s ' ' `,--ems - !s'„r Figure 10.2 • :1 • - Y. ,�_-�. .A�'i ?•.'i"�-.►fir: ,E1VED Note: Model LFP4218 Includes 15 Lbs. of Fireglass 11/08/2019 10 ASPEN BUILDING DEPARTMENT GLASS INSTALLATION CONT. Figure 11.1 • •T 11 GLASS FLAME STABILIZER INSTALLATION 1. ALL LFP MODELS ARE SUPPLIED WITH A GLASS FLAME STABILIZER THAT HELPS BURNER FLAME MAINTAIN A VERTICAL POSITION. 2. LOCATE GLASS FLAME STABILIZER CLIPS AND INSERT GLASS FLAME STABILIZER INTO BOTH. CENTER GLASS FLAME STABILIZER SO THAT THERE IS SAME CLEARANCE ON LEFT AND RIGHT SIDES. Glass Flame Stabilizer Glass Flame Stabilizer Clip dEIVED 11/08/2019 11 ASPEN BUILDING DEPARTMENT GLASS FLAME STABILIZER INSTALLATION CONT. 3. GLASS FLAME STABILIZER SHOULD BE SEATED AGAINST FIREPLACE FLOOR AS SHOWN Installed Glass Flame Stabilizer OPERATING GUIDELINES Upon completing the gas line connection, a small amount of air will be in the lines. When first lighting the pilot light, it will take a few minutes for the lines to purge themselves of this air. Once the purging is complete, the pilot and burner will light and operate as indicated in the instruction manual. Subsequent lighting of the appliance will not require such purging. WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE. IMPORTANT: TURN OFF GAS BEFORE SERVICING APPLIANCE. IT IS RECOMMENDED THAT A COMPETENT SERVICE TECHNICIAN PERFORM THESE CHECKUPS AT THE BEGINNING OF EACH HEATING SEASON. WARNING: THE FLOW OF COMBUSTION AND VENTILATION AIR MUST NOT BE OBSTRUCTED. When lit for the first time, the appliance le- will emit a slight odor for an hour or two. Flame _ _ Of. ��This is due to paint and lubricants used Sensor Ignitor Pin the manufacturing process. The main . i B „ilotrner burner flame characteristics are steady, not lifting or floating. Typically, the top .mm� 1/4 inch of the flame sensor should be �_ engulfed in the pilot flame. A periodic II check of these characteristics is RECEI E1/ necessary (Figure 12.2). Figure 12.2 • : 2019 12 ASPEN BUILDING DEPARTMENT MAINTENANCE INSTRUCTIONS IMPORTANT: THE APPLIANCE AREA MUST BE KEPT CLEAR AND FREE FROM COMBUSTIBLE MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS. Visually inspect pilot periodically. Brush or blow away any dust or linen accumulations. If pilot orifice is plugged, disassembly may be required to remove any foreign material from orifice or tubing. Venting system should be periodically examined by a qualified service technician or agency to ensure proper air flow. WIRING DIAGRAM 7-7 � A HIGH _ m O LIMIT 0 c SWITCH a a e � I ORG WHT / \ WHT S PIN MOLEX CONNECTER THTP / 1 2 LL > > m ¢ m m O' O m TP Q H O f 0 !R TH �Ji� D SIZE BATTERY BLX R B H R RED A RE� WHT I 1 D SIZE 0 11/4 BATTERY Li DAMPER SWITCH RED BLX A REMOTE/WALL SWITCH CONNECTION RECEIVED 11/08/2019 13 ASPEN BUILDING DEPARTMENT FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not light pilot by hand. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance • Do not touch any electric switch: • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions C. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the gas control system which has been under water. LIGHTING INSTRUCTIONS ELEC. SPARK TO PILOT 1. "STOP" Read the safety information on 5. Wait (5) minutes to clear out any gas. Then page 11. smell for gas, including near the floor. If you 2. Set the switch to "OFF". smell gas, STOP! Follow "B" in the safety 3. Remove batteries from battery pack. information on page 11. If you don't smell 4. This appliance is equipped with an ignition gas, go to next step. device which automatically lights the burner. 6. Install (2) D batteries in battery pack. Do not try to light the burner by hand. 7. Turn ON/OFF rocker switch to "ON". 8. If the appliance will not operate, follow the �• instructions "To turn Off Gas To Appliance" O and call your service technician or gas supplier. PILOT O .� �� o Qi) ; I © NOTE: DAMPER CONTROL LEVER MUST �' ® 2 , r�© BE IN THE "OPEN" POSITION TO IGNITE. 0. GAS VALVE RECEIVED 11/08/2019 14 ASPEN BUILDING DEPARTMENT TO TURN OFF GAS TO APPLIANCE 1. Turn ON/OFF rocker switch to "OFF" 2. Remove batteries from appliance if service is to be performed. LPG (PROPANE) WARNING THE FOLLOWING WARNING APPLIES TO INSTALLATIONS USING L.P. (PROPANE GAS): WARNING: To avoid possible injury, fire and explosion, please read and follow these precautions and all instructions of this appliance before operating. This appliance uses L.P. (Propane) gas which is heavier than air and will remain at the floor level is there is a leak. Before lighting, smell at floor level and/or use other means (such as using a soap solution on all piping and connections, using a gas detector, etc.) to check for gas leaks. NOTE: L.P. (Propane) gas can become odorless and CANNOT always be detected by smell. If you smell gas, detect a gas leak or suspect that a gas leak exists, follow these rules: 1. Get all people out of building. 2. DO NOT light matches. DO NOT turn electric lights or switches on or off in area. DO NOT use an electric fan to remove gas from area. DO NOT use a telephone inside of building. 3. Shut off gas at L.P. tank outside of building. 4. Telephone gas company and fire department. Ask instructions. Before hanging up, give your name, address and phone number. DO NOT go back into building. If your L.P. tank runs out of fuel, turn off gas at the appliance. After L.P. tank is refilled, appliance must be re-lit according to manufacturer's instructions. If The gas control has been exposed to WATER in any way, DO NOT try to use it. It must be replaced. DO NOT attempt repair on gas control or appliance. Tampering is DANGEROUS and voids all warranties. Any component that is found to be faulty, must be replaced with an approved component. IMPORTANT: Always keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids. Never obstruct the flow of combustion and ventilation air. Keep the front of the appliance clear of all obstacles and materials. To obtain proper operation, it is imperative that the pilot and main burner flame characteristics are steady, not lifting or floating. Typically the top 1/4 Inch of the flame sensor should be engulfed in the pilot flame. (Figure 12.2) RECEIVED 11/08/2019 15 ASPEN BUILDING DEPARTMENT TROUBLE SHOOTING With proper installation and maintenance, your new Gas Fireplace should provide years of trouble-free service. If you do experience a problem, refer to the trouble shooting guide shown below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken. SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Ignitor will not spark or pilot 1. No gas supply or shutoff 1. Check to see if you have will not light valve is OFF gas supply and that equipment shutoff valve is opened 2. Air in gas line 2. Repeat lighting procedure several times to purge all air out of lines. If after repeated attempts appliance does not light, call for qualified service and repair 3. Construction debris 3. Remove debris and dirt, clogging pilot orifice inspect and clean any other possible obstructions 4. Low gas pressure 4. Contact your gas supplier to check pressure 5. Kinked pilot line 5. Have a qualified technician replace pilot line 6. Control valve is not opening 6. Replace control valve 7. No power to unit 7. Check that main power is on or ignition module and that all wire connections are made correctly to ignition model (see Wiring Diagram, page 11). Check battery voltage and replace batteries if needed. If battery voltage is good and module does not operate, have module replaced. 8. Damper Closed 8. Open Damper SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Pilot will not stay lit 1. Loose wiring on ignitor 1. Check wiring connection. wire to ignition module Refer to wiring diagram (see and/or poor ground to Wiring Diagram, page 11) ignition module 2. Pilot flame too low to sense 2. Clean and adjust pilot burner and check gas supply and inlet pressure to unit Note:Have a qualified technician replace pilot assembly if broken or �► corroded RECEIVED 3. Flame sensor defective 3. Replace flame sensor 11/08/2019 16 ASPEN BUILDING DEPARTMENT TROUBLE SHOOTING (CONT'D) Frequent pilot outage 1. Pilot flame may be too low, 1. Clean and adjust pilot flame causing safety pilot to for maximum flame im- "drop out" pingement on flame probe 2. Improper venting or 2. Have vent system inspected, excessive blockage including termination cap. Remove any restriction or obstruction Slight smoke or order during 1. Residues from 1. Problem will stop after a few initial operation manufacturing process hours of operation Pilot and Main Burner go out 1. High Limit Switch is 1. Allow unit to cool. Then while in operation defective of has reached repeat lighting instructions. its maximum temperature 2. If above does not allow for ignition, check high limit switch. Place jumper lines across high limit switch. If you can re-ignite the pilot your high limit switch is defective. Replace high limit switch before using 3. No L.P. in tank 3. Check L.P. tank. You may be out of fuel RECEIVED 11/08/2019 17 ASPEN BUILDING DEPARTMENT REPLACEMENT PARTS THE FOLLOWING REPLACEMENT PARTS ARE AVAILABLE FROM YOUR GOLDEN BLOUNT DEALER ITEM PART# DESCRIPTION 1 STP-TV-127 Gas Valve - N/G 2 STP-TV-128 Gas Valve - LP 3 LFP-103 1/4" Pilot Gas Line 4 LFP-104 3/8" Burner gas Line (4218) 4 LFP-104-6018 1/2" Burner Gas Line (6018) 4 LFP-104-7218 1/2" Burner Gas Line (7218) 5 _ LFP-105 15# Fireglass (4218) 6 TV-106 On/Off Switch 7 STP-LFP-107 Pilot Assembly- NAT 8 STP-LFP-108 Pilot Assembly- LP 9 STP-TV-132 Flame Sensor 10 TV-130 3/8" Shut Off Valve 11 LFP-111 Burner Orifice NAT(4218) 11 LFP-111-6018 Burner Orifice NAT(6018) 11 LFP-111-7218 Burner Orifice NAT(7218) 12 LFP-112 Burner Orifice LP (4218) 12 LFP-112-6018 Burner Orifice LP (6018) 12 _ LFP-112-7218 Burner Orifice LP (7218) 13 TV-124 Temp Limit Switch 14 TV-125 Damper Switch 15 STP-TV-129 Ignition Module 16 STP-TV-126 Battery Pack C) :Qt!$.1.44ilitZiPis 00 I 1 0 0 00 lirli 1 ;���1 �1 "w 1 ,p e 0 ®©j / Q 1N 1N itc_3i `43i m A m a, , P L RECEIVED S PIN MOLEX CONNECTER M Y ° C 2 J ' m m m ° ° m 11/08/2019 18 ASPEN BUILDING DEPARTMENT TWO YEAR LIMITED WARRANTY THIS WARRANTY IS LIMITED TO TOP-VENT GAS FIREPLACES MANUFACTURED AND ASSEMBLED BY GOLDEN BLOUNT. IF GOLDEN BLOUNT FINDS THAT ANY PART OR PORTION OF THE FIREPLACE COVERED BY THIS WARRANTY IS DEFECTIVE IN MATERIAL OR WORKMANSHIP UNDER NORMAL USE AND SERVICE AS DESCRIBED IN THE INSTALLATION AND OPERATING INSTRUCTIONS, GOLDEN BLOUNT WILL TAKE THE FOLLOWING ACTIONS: 1. WITHIN THE FIRST YEAR FROM THE DATE OF INSTALLATION, GOLDEN BLOUNT SHALL, AT ITS OPTION REPLACE OR REPAIR ANY SUCH DEFECT IN MATERIAL OR WORKMANSHIP, AT GOLDEN BLOUNT'S EXPENSE, INCLUDING A REASONABLE LABOR ALLOWANCE AS DETERMINED BY GOLDEN BLOUNT. GOLDEN BLOUNT SHALL NOT BE RESPONSIBLE FOR ANY OTHER LABOR COSTS, OR EXPENSES, INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES. 2. DURING THE SECOND YEAR AFTER THE DATE OF INSTALLATION, GOLDEN BLOUNT SHALL SUPPLY REPLACEMENT PARTS AT THE CURRENT WHOLESALE PRICE, BUT GOLDEN BLOUNT SHALL NOT BE RESPONSIBLE FOR ANY LABOR, TRANSPORTATION, OR THE INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. 3. ALL FACTORY OPTIONAL COMPONENTS OR ACCESSORIES FOUND TO BE DEFECTIVE WILL BE REPAIRED OR REPLACED WITHOUT CHARGE DURING THE FIRST YEAR AFTER INSTALLATION. GOLDEN BLOUNT MAY DISCHARGE ITS ENTIRE WARRANTY LIABILITY BY REFUNDING THE PRICE OF THE PRODUCT. PRODUCTS MADE BY OTHER MANUFACTURERS, SOLD WITH THE FIREPLACE OR THEREAFTER ARE NOT COVERED BY THIS LIMITED WARRANTY. THE USE OF OTHER UNAUTHORIZED COMPONENTS WILL MAKE THIS WARRANTY NULL AND VOID. THIS LIMITED WARRANTY WILL BE VOID IF THE APPLIANCE IS NOT INSTALLED BY A QUALIFIED INSTALLER AND ACCORDING TO THE INSTALLATION INSTRUCTIONS. THE LIMITED WARRANTY ALSO IS VOID IF THE FIREPLACE IS NOT OPERATED, AT ALL TIMES, ACCORDING TO THE OPERATING INSTRUCTIONS FURNISHED. SOME STATES DO NOT ALLOW EXCLUSION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LIMITS ON THE DURATION OF IMPLIED WARRANTIES SO THESE LIMITATIONS MAY NOT APPLY TO YOU. GOLDEN BLOUNT RESERVES THE RIGHT TO INVESTIGATE ANY AND ALL CLAIMS AGAINST THIS WARRANTY AND TO DECIDE ON THE METHOD OF SETTLEMENT. GOLDEN BLOUNT IS NOT RESPONSIBLE FOR WARRANTY WORK COMPLETED WITHOUT OBTAINING GOLDEN BLOUNT'S CONSENT. GOLDEN BLOUNT EMPLOYEES AND DEALERS HAVE NO RIGHT TO ALTER THIS WRITTEN WARRANTY. WARRANTY INFORMATION PLEASE BE ABLE TO PROVIDE THE FOLLOWING INFORMATION WHEN COMMUNICATING WITH GOLDEN BLOUNT OR ITS DEALERS OR DISTRIBUTORS REGARDING SERVICE UNDER THIS WARRANTY. MODEL NO. Golden Blount, Inc. SERIAL NO. 4301 Westgrove Dr. DATE OF PURCHASE Addison, TX. 75001 (972) 250-3113 RECEIVED 11/08/2019 19 ASPEN BUILDING DEPARTMENT