Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.517 Park Cir.0161.2018 (21).ARBK
7. e '` LL f -' ; { RS' L .:',..-:-.',47_.. - ---- -____ - - . ;,; .- ‘ - -.-7- .- -,,,... SunPower° X22-360-C-AC 1 Residential AC Module Series Design-Driven Advantages 022 • #1 module aesthetics and efficiency, • Unmatched module reliability2 ..■■.11 SERIES • No electrolytic capacitors ■ ■■■■ ..11.1179 • 25-year Combined Power and Product ■■■■ Warranty ■■■■■ Maximize Value for Roof •�■: • Size system for roof, not string inverter 1111111. • Optimize performance of each module . IIII.■.■ 11.111111111111 Expand Deployment Options .111N.1111 • Complex roofs and partial shading 11E= ii • Small systems • System expandability Simplify & Speed Installation Optimize System and Installation Efficiency • Factory-integrated microinverter • Robust,double locking AC connectors SunPower®AC Modules,which include a factory-integrated • Design flexibility offsite and onsite SunPower microinverter, provide a revolutionary combination of high • No DC string sizing process efficiency,high reliability,and module-level DC-to-AC power conversion. • Fewer installation steps than competing systems Designed specifically for use with SunPower InvisiMountTM and the • Intuitive commissioning SunPower Monitoring System,SunPower AC Modules enable rapid installation,best-in-class system aesthetics,and intuitive visibility into Component of Complete System Built for use with SunPower®InvisiMountT"^ system performance.All this comes with the best Combined Power • and the SunPower Monitoring System and Product Warranty in the industry. • Superior system reliability and aesthetics O 10 se r y a sunpower.com RECEIVED Datasheet SUN 1 O Y 'd/ E R® t SunPower® X22-360-C-AC I Residential AC Module Series Power Data Tested Operating Conditions SPR-X22-360-C-AC Operating Temp. -40°F to+185°F(-40°C to+85°C) Nominal Power3(Pnom) 360 W Max.Ambient 122°F(50°C) Power Tolerance +5/-0% Temp. Avg.Panel Efficiency4 22.2% Max.Load Wind:62 psf,3000 Pa,305 kg/m2 front&back Temp.Coef.(Power) 0 290�0/o C Snow:125 psf,6000 Pa,611 kg/m2 front •Three bypass diodes Impact Resistance 1 inch(25 mm)diameter hail at 52 mph(23 m/s) Shade Tolerance • Integrated module-level maximum power point tracking Warranties and Certifications AC Electrical Data Warranties • 25 year limited power warranty • 25-year limited product warranty Output @ 240 V(min./nom./max.) 211/240/264 V UL listed to UL 1741,including: Output @ 208 V(min./nom./max.) 183/208/229 V • IEEE1547/1547a and IEEE1547.1/1547.1 a Utility Operating Frequency(min./nom./max.) 59.3/60.0/60.5 Hz Interactive Output Power Factor(min.) 0.99 • PV Rapid Shutdown Equipment AC Max.Continuous Output Current @ 240 V 1.33 A • Equipment Grounding AC Max.Continuous Output Current @ 208 V 1.54 A • UL 6703,UL 9703 Connectors and cables(load break disconnection) AC Max.Cont.Output Power 320 W • UL 1703 PV Modules(Type 2 fire rating) DC/AC CEC Conversion Efficiency 96.0% Max.Units Per 20 A Branch Circuit @ 240 V 12(single phase) Certifications Enables installation in accordance with: Max.Units Per 20 A Branch Circuit @ 208 V 10(two pole) NEC 690.E No active phase balancing for 3 phase • NEC 690.12 Rapid Shutdown(inside and outside installations the array) • NEC 690.15 AC Connectors,690.33(A)-(E)(1) FCC and ICES-003 Class B Mechanical Data Solar Cells 96 Monocrystalline Maxeon Gen III When used with InvisiMount racking(UL 2703): High-transmission tempered glass with • Integrated grounding and bonding Front Glass • Class A fire rated anti-reflective coating Environmental Rating Outdoor rated PID Test Potential-induced degradation free Frame Class 1 black anodized(highest AMA rating) Weight 45.5 lbs(20.6 kg) 280 mm'' [11.02 in] Recommended Max. ,l 1.3 in.(33 mm) ���� Module Spacing ���� i 7 E,�: 1107 mm E� [43.6 in] v ■■ 1046 mm _ ■_ . 1.■ [41.2 in] l I. 30 mm it [1.2 in] 1Highest of over 3,200 silicon solar panels,Photon Module Survey,Feb.2014 V ,� 2#1 rank in"PV Module Durability Initiative Public Report,"Fraunhofer CSE,Feb 2013.Five out of 1• the top eight largest manufacturers were tested.Campeau,Z.et al."SunPower Module 1558 mm Degradation Rate;'SunPower white paper,Feb 2013.See wwwsunpower.com/facts for details. [61.3 in] 3Standard Test Conditions(1000 W/m2 irradiance,AM 1.5,25°C).NREL calibration standard:SOMS current,LACCS FF and voltage.At DC voltage is fully contained within the module. 4Based on average of measured power values during production. Please read the safety and installation instructions for details. � �'�� See www.sunpower.com/facts for more reference information. Weft LJ For more details,see extended datasheet:www.sunpower.com/datasheets. Document#516046 Rev D/LTR-US ©December 2016 SunPower Corporation.All rights reserved.SUNPOWER,the SUNPOWER logo,MAXEON and InvisiMount �+ 1 1 1� 1 n \ A Y/ r 1.1 C are trademarks or registered trademarks of SunPower Corporation in the U.S.and other countries as wet.Specifications S U \`I� 'P V� 1E- iP included in this datasheet are subject to change without notice.