HomeMy WebLinkAboutFile Documents.905 Chatfield Rd.0111.2018 (174).ARBK nu eitiEWE-"")
REScheck Software Version 4.6.4p
rill414(1 Compliance Certificate [1' o1 '14 "2019 j
FOR COOt
justinh
Project Silverstein Residence = (aPui0 L1CF'11
Energy Code: 2015 IECC ir •
Location: Aspen, Colorado a 10/9/18 4 to
Construction Type: Single-family % ;u 50 02 rr*I Project Type: New Construction l� •• :2
-53
Conditioned Floor Area: 5,010 ft2 +1, 0,�. •• •;
Glazing Area 4
Climate Zone: 76(9922 HDD) III k;YONA 1—
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
905 Chatfield Rd Bill & Karyn Silverstein Gage Reese
Aspen, CO 81611 905 Chatfield Rd. CCY Architects
Aspen, CO 81611 228 Midland Avenue
Basalt, CO 81621
970-927-4925
greese@ccyarchitects.com
Compliance: Passes using UA trade-off
Compliance: 6.1%Better Than Code Maximum UA: 1278 Your UA: 1200
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Floor Over Crawl Space: All-Wood joist/Truss:Over Unconditioned Space 1,855 38.0 0.0 0.026 48
Floor Over Outside: All-Wood joist/Truss:Over Outside Air 68 49.0 5.0 0.019 1
Slab On Grade: Slab-On-Grade:Unheated 83 10.0 0.684 57
Insulation depth: 6.0'
Below Grade Wall: Solid Concrete or Masonry 1,029 14.0 10.0 0.032 33
Wall height: 9.5'
Depth below grade: 9.5'
Insulation depth: 9.5'
Below Grade Wall (w/duct): Solid Concrete or Masonry 244 0.0 10.0 0.051 12
Wall height: 9.5'
Depth below grade: 9.5'
Insulation depth: 9.5'
Below Grade Wall at Crawl Space: Solid Concrete or Masonry 95 14.0 0.0 0.049 5
Wall height: 9.5'
Depth below grade: 9.5'
Insulation depth: 9.5'
Above Grade Wall: Wood Frame, 16" o.c. 5,253 35.0 5.0 0.035 86
Window: Wood Frame:Double Pane with Low-E 2,193 0.320 702
Glass Door: Glass 409 0.320 131
Solid Door: Solid 180 RECEIVED
Project Title: Silverstein Residence Report dzit2/t1021O18
Data filename:J:\jobs\2017 -Jobs\17085.00 - Silverstein Res\Mechanical\Calculations\REScheck\17085- Page 1 of10
REScheck.rck ASPEN
BUILDING DEPARTMENT
Gross Area Cavity Cont.
Assembly or R-Value R-Value
U-Factor UA
Perimeter
Above Grade Stone Wall: Wood Frame, 16" o.c. 286 35.0 10.0 0.028 7
Window: Wood Frame:Double Pane with Low-E 20 0.320 6
Above Grade Concrete Wall: Solid Concrete or Masonry:Exterior Insulation 108 0.0 10.0 0.077 8
1/4" Sloped Roof: Cathedral Ceiling 964 49.0 10.0 0.018 17
3/4" Sloped Roof: Cathedral Ceiling 1,845 49.0 10.0 0.018 33
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Joshua Westerlind - Mechanical Engineer C atilaCIA 10/9/18
Name-Title Signature Date
Project Notes:
Calcs By:Joshua Westerlind - Rader Engineering (970)-845-7910
"")
01/14/2019 j
FOR Cat U M I
justinh
RECEIVED
Project Title: Silverstein Residence Report d12/ 0 2-618
Data filename:J:\jobs\2017 -Jobs\17085.00 - Silverstein Res\Mechanical\Calculations\REScheck\17085- Page 2 of10
REScheck.rck ASPEN
BUILDING DEPARTMENT
REScheck Software VersionChecklist 4.6.4
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and Complies
103.2 documentation demonstrate Does Not
[PR1]1 energy code compliance for the
building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, ;Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. ['Not Observable
fil, Systems serving multiple ENot Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 1
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling:
Manual J or other methods ['Not Observable
Btu/hr Btu/hr
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) RECEIVED
Project Title: Silverstein Residence Report d12/ Vi2-818
Data filename:J:\Jobs\2017 -Jobs\17085.00 - Silverstein Res\Mechanical\Calculations\REScheck\17085- Page 3 of10
REScheck.rck ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.2 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies
[FO1]1 ❑ Unheated ❑ Unheated ElDoes Not table for values.
.0 ❑ Heated ❑ Heated [Not Observable
ENot Applicable
402.1.2 Slab edge insulation ft ft EComplies See the Envelope Assemblies
[FO3]1 depth/length. ❑Does Not table for values.
['Not Observable
1 ❑Not Applicable
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
[FO4]1 insulation R-value.Where interior R- R- ❑Does Not table for values.
O insulation is used, verification ['Not Observable
may need to occur during
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies
[FO5]1 insulation installed per ❑Does Not
O manufacturer's instructions. ['Not Observable
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[FO6]1 insulation depth of burial or ❑Does Not table for values.
�, distance from top of wall.
❑Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies
[FO11]2 to protect exposed exterior ❑Does Not
insulation and extends a
minimum of 6 in. below grade. ['Not Observable
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies
[FO controls installed. ❑Does Not
['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) J RECEIVED
Project Title: Silverstein Residence Report dzit2/Wile 18
Data filename: J:\Jobs\2017 -Jobs\17085.00 - Silverstein Res\Mechanical\Calculations\REScheck\17085- Page 4 of10
REScheck.rck ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, ;Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 ❑Not Observable
II ❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). I ❑Does Not table for values.
402.3.3,
402.3.6, [Not Observable
402.5 ❑Not Applicable
[FR2]1
4
303.1.3 U-factors of fenestration products ❑Complies
[FR4]1 are determined in accordance EDoes Not
with the NFRC test procedure or ['Not Observable
taken from the default table.
❑Not Applicable
402.1.1 Mass wall exterior insulation R- R- R- ❑Complies See the Envelope Assemblies
[FR10]1 value. If more than 1/z of the EDoes Not table for values.
"111 insulation is on the wall interior, ['Not Observable
the interior insulation
requirement applies and ❑Not Applicable
verification may need to occur
during Insulation Inspection.
303.2 Mass wall exterior insulation ❑Complies
[FR11]1 installed per manufacturer's ❑Does Not
instructions. ['Not Observable
❑Not Applicable
402.4.1.1 Air barrier and thermal barrier EComplies
[FR23]1 installed per manufacturer's EDoes Not
O instructions. ['Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built EComplies
[FR20]1 is listed and labeled as meeting EDoes Not
O AAMA/WDMA/CSA 101/I.S.2/A440 ['Not Observable
or has infiltration rates per NFRC
400 that do not exceed code ❑Not Applicable
limits.
402.4.5 :IC-rated recessed lighting fixtures■ EComplies
[FR16]2 sealed at housing/interior finish ❑Does Not
;and labeled to indicate <_2.0 cfm
leakage at 75 Pa. ['Not Observable
❑Not Applicable
403.2.1 Supply and return ducts in attics EComplies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
A, >= 3 inches in diameter and >= ['Not Observable
R-6 where < 3 inches. Supply and
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.3.5 ,1 Building cavities are not used as ❑Complies
[FR15]3 Iducts or plenums. ❑Does Not
O ['Not Observable
AM ❑Not Applicable
403.4 I HVAC piping conveying fluids R- R- ❑Complies
[FR17]2 above 105 °F or chilled fluids ❑Does Not
6 below 55 °F are insulated to >_R ❑Not Observable
j ❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) J RECEIVED
Project Title: Silverstein Residence Report dzit2/Wile 1 8
Data filename: J:\Jobs\2017 -Jobs\17085.00 - Silverstein Res\Mechanical\Calculations\REScheck\17085- Page 5 of10
REScheck.rck ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
403.4.1 Protection of insulation on HVAC '❑Complies
[FR24]1 piping. ❑Does Not
d 1111 [Not Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- ❑Complies
[FR18]2 >_R-3. ❑Does Not
J ❑Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are ❑Complies
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts.
[Not Observable
,❑Not Applicable
—
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) J RECEIVED
Project Title: Silverstein Residence Report dzit-/Wile 18
Data filename: J:\Jobs\2017 -Jobs\17085.00 - Silverstein Res\Mechanical\Calculations\REScheck\17085- Page 6 of10
REScheck.rck ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
303.1 ;All installed insulation is labeled '❑Complies
•
[IN13]2 or the installed R-values ❑Does Not
provided. Ilir [Not Observable
❑Not Applicable
402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Woo-d ❑Does Not table for values.
['Nip ❑ Steel ❑ Steel [Not Observable
tio ❑Not Applicable
303.2, Floor insulation installed per ❑Complies
402.2.7 manufacturer's instructions and ❑Does Not
[IN2]1 in substantial contact with the
CO underside of the subfloor, or floor ['Not Observable
framing cavity insulation is in ❑Not Applicable
contact with the top side of
sheathing, or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
402.1.1, Wall insulation R-value. If this is a R- R- EComplies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Woo-d ❑Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ['Not Observable
[IN3]1 exterior,the exterior insulation
requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. ❑Does Not
[Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) J RECEIVED
Project Title: Silverstein Residence Report dzit-/Wile 18
Data filename: J:\Jobs\2017 -Jobs\17085.00 - Silverstein Res\Mechanical\Calculations\REScheck\17085- Page 7 of10
REScheck.rck ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID_
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood EDoes Not table for values.
402.2.2, j ❑ Steel ❑ Steel [Not Observable
402.2.6
[FI1]1 ENot Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. EDoes Not
[F12]1 Blown insulation marked every
300 ft2. ENot Observable
ENot Applicable
402.2.3 !Vented attics with air permeable EComplies
[F122]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
;extends over insulation. ❑Not Observable
' ❑Not Applicable
402.2.4 Attic access hatch and door R- R- EComplies
[F13]1 insulation >_R-value of the ❑Does Not
adjacent assembly.
[Not Observable
❑Not Applicable
402.4.1.2 :Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = EComplies
[F117]1 ach in Climate Zones 1-2, and ❑Does Not
'<=3 ach in Climate Zones 3-8.
ENot Observable
ENot Applicable
403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 EComplies
[F14]1 cfm/100 ft2 across the system or ft2 ft2 EDoes Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ['Not Observable
tests,verification may need to ENot Applicable
occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 EComplies
[F127]1 determine air leakage with ft2 ft2 Does Not
either: Rough-in test:Total
leakage measured with a ['Not Observable
pressure differential of 0.1 inch ENot Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated EComplies
[F124]1 by manufacturer at<=2%of ❑Does Not
design air flow.
[Not Observable
ENot Applicable
403.1.1 :Programmable thermostats EComplies
[F19]2 installed for control of primary EDoes Not
j heating and cooling systems and
:initially set by manufacturer to ['Not Observable
:code specifications. ❑Not Applicable
i
403.1.2 Heat pump thermostat installed ❑Complies
[F110]2 on heat pumps. EDoes Not
ENot Observable
❑Not Applicable
403.5. Circulating service hot water ❑Complies
[F111]z systems have automatic or EDoes Not
accessible manual controls.
qLlNOt Observable
i ENot Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) J RECEIV D
Project Title: Silverstein Residence Report dzit2/ 0/2-018
Data filename: J:\Jobs\2017 -Jobs\17085.00 - Silverstein Res\Mechanical\Calculations\REScheck\17085- Page 8 of10
REScheck.rck ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.6.1 ;All mechanical ventilation system ' •Complies
[F125]z fans not part of tested and listed •Does Not
HVAC equipment meet efficacy
and air flow limits. •Not Observable
403.2 j Hot water boilers supplying heat ❑Complies
[F126]z through one-or two-pipe heating ❑Does Not
ailsystems have outdoor setback
control to lower boiler water ❑Not Observable
temperature based on outdoor ❑Not Applicable
j temperature.
403.5.1.1 Heated water circulation systems ❑Complies
[F128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe. Gravity and thermos- ENot Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
41'occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 'Electric heat trace systems ❑Complies
[F129]z comply with IEEE 515.1 or UL El Does Not
515. Controls automatically
adjust the energy input to the ['Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
:piping.
403.5.2 Water distribution systems that 1 ❑Complies
[F130]z have recirculation pumps that EDoes Not
pump water from a heated water
supply pipe back to the heated ['Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
:water piping to 104°F.
403.5.4 Drain water heat recovery units ❑Complies
[F131]z tested in accordance with CSA ❑Does Not
B55.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies
[F16]1 fixtures or 75%of permanent EDoes Not
fixtures have high efficacy lamps.
Does not apply to low-voltage ❑Not Observable
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have ❑Complies
[F123]3 no continuous pilot light. EDoes Not
J 111 ❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) J RECEIVED
Project Title: Silverstein Residence Report dzit2/Wile 18
Data filename: J:\Jobs\2017 -Jobs\17085.00 - Silverstein Res\Mechanical\Calculations\REScheck\17085- Page 9 of10
REScheck.rck ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
401.3 Compliance certificate posted. '❑Complies
[F17]2 ❑Does Not
[Not Observable
❑Not Applicable
303.3 Manufacturer manuals for EComplies
[F118]3 mechanical and water heating ❑Does Not
systems have been provided.
[Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) RECEIVED
Project Title: Silverstein Residence Report d12/ 021618
Data filename:J:\Jobs\2017 -Jobs\17085.00 - Silverstein Res\Mechanical\Calculations\REScheck\17085- Page 10 of10
REScheck.rck ASPEN
BUILDING DEPARTMENT
Li( 2015 IECC Energy
Efficiency Certificate
Insulation Ratin. R-Value
Above-Grade Wall 40.00
Below-Grade Wall 24.00
Floor 38.00
Ceiling / Roof 59.00
Ductwork (unconditioned spaces):
Glass& Door Rating U-Factor SHGC
Window 0.32
Door 0.32
Heating&Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments
RECEIVED
12/03/2018
ASPEN
BUILDING DEPARTMENT