HomeMy WebLinkAboutFile Documents.610 S West End St.0068.2019.ARBK 0068-2019-ARBK_BuildingComments_1
MILLS_F304_PROPOSED PLAN_.pdf(8)
Page: [1] MILLS_F304_PROPOSED PLAN=ID.CS_COVER
SHEET Provide an asbestos abatement
File Name: MILLS_F304_PROPOSED PLAN_.pdf clearance report.
Subject: asbestos
Provide an asbestos abatement Author: nickt
clearance report. Color: •
Page: [3] MILLS_F304_PROPOSED
PLAN_-ID.02_ELELCTRICAL&LIGHTING New skylights must have
File Name: MILLS_F304_PROPOSED PLAN_.pdf minimum 4"curb, minimum 30
MilSubject: PlanCheck mil pvb interlayer, and maximum
-- AuthoC r: nickt 0.28 U-factor. 2015 IBC 2405
��- \ Riiii,r,
olor: ■ and 2015 IECC 402.1.2.
I
M ili i'i,,=-- t 1.
p3
- Page: [3] MILLS_F304_PROPOSED
PLAN -ID.02 ELELCTRICAL& LIGHTING Show the dryer exhaust duct
- - routing and vent termination. If
I, File Name: MILLS_F304_PROPOSED PLAN_.pdf
__.... is Subject: PlanCheck creating a new termination, show
Author: nickt distance to nearby operable
kg‘...
I" Color: • windows, doors, and common
•ems. m - walkways/sidewalks. If running
i� -= y new ductwork, note method of
,��P y!Fd"=-I penetration protection if it
i I �I Ear: z penetrates a rated assembly.
2015 IBC ch 7, 2015 IMC ch 5.
Page: [5] MILLS_F304_PROPOSED PLAN_-ID.03_WALL
F,eEaa"EINSER, ASSEMB This building is type VA
File Name: MILLS_F304_PROPOSED PLAN_.pdf construction, requiring the
Subject: PlanCheck roof/ceiling to be 1 hour fire
-�^�_^°"°"9=;ae�^Po°=^""°"° Author: nickt
rated (2015 IBC table 601).
re° to""�` Provide a listed assembly for the
�edazo;s'eb"°tware Color: •
ceiling anywhere you are
disturbing it.
AL n^T Page: [5] MILLS_F304_PROPOSED PLAN_-ID.03_WALL
•- _ - ASSEMB Provide the listed UL assembly
n-_ File Name: MILLS_F304_PROPOSED PLAN_.pdf (UL U309). However, I believe
._ _ t�t�ttttt,.ttttt_�_ Subject: PlanCheck the Gant dwelling separation
Author: nickt walls are staggered stud, so you
� °---r=-•-•• '-°�p�=•® Color: • may wish to use the QuietRock
..�.,oa..... -,
F
1, assembly that references U340.
•e In any case, provide the listed
�;e he
he'�a LL� assembly by UL.
Page: [5] MILLS_F304_PROPOSED PLAN_-ID.03_WALL
�E„E,o„, ASSEMB Exposed combustible mantels or
File Name: MILLS_F304_PROPOSED PLAN_.pdf trim is permitted to
Subject: PlanCheck be placed directly on the
Author: nickt masonry fireplace front
Color: • surrounding the fireplace
opening, provided such
combustible materials shall not
�.®�.. be placed within 6
fl inches (153 mm)of a fireplace
opening. Combustible
material directly above and
within 12 inches
(305 mm)of the fireplace
opening shall not project
more than 1/8 inch (3.2 mm)for
each 1-inch (25 mm)
distance from such opening.
Combustible materials
located along the sides of the
fireplace opening that
project more than 11/2 inches
(38 mm)from the face
of the fireplace shall have an
additional clearance
equal to the projection. Revise.
2015 IBC 2111.12
Page: [5] MILLS_F304_PROPOSED PLAN -ID.03 WALL
ASSEMB — — Existitng hearth extension may
11111117,
! File Name: MILLS_F304 PROPOSED PLAN df not be disturbed beyond cement
— —p board and tile unless replaced
Subject: PlanCheck
Author: nickt with entirely non-combustible
ar,:,R;Eu`E Color: • construction per fireplace install
instructions.
_ __ _ Page: [6] MILLS_F304_PROPOSED PLAN=ID.04_DOOR-
_ m - WINDOW SCH Z7 DETAILS New exterior door must have a
_ = File Name: MILLS_F304_PROPOSED PLAN_.pdf U factor of no more than 0.28.
Subject: PlanCheck 2015 IECC 402.1.2.
_ _ a = Author: nickt
Color: ■