File Documents.1001 E Cooper Ave.0039.2019 (6).ARBK
039-201 9-ARBK Owner's FIREPLACE GAS LOG SET RH0 PETERSON co. Manual AND BURNER SPEC 2019-12-05 /reaIffyre P REMIUNI GAS LOGS Standard Burner Systems: G4-12(P) `� • FOR INSTALLATION IN G4-16/19(P) - � � SOLID-FUEL BURNING -. FIREPLACES G4-18/20(P) '" Af •.;?`. % _-w , G4-30(P) - 1 G4-36(P) r•„" .. " . .r -.: �iar_--t 1. , • G4-42(P) i .- G4-48(P) "- _ --- �.__. G4-60(P) �� 'ter'—�' W akr(WOG4-24) Shown G4/GX4 SERIES BURNER Important: Read these instructions carefully before A WARNING starting installation of the gas log set. If the information in this manual is not followed exactly, a fire or explosion may result, causing This burner system is to be installed only in a solid-fuel- property damage, personal injury, or loss of life. burning fireplace with a working flue and constructed of noncombustible material. Solid fuels shall not be Do not store or use gasoline or otherflammable burned in a fireplace where this gas log set is installed. vapors and liquids in the vicinity of this or any The installation, including provisions for combustion, other appliance. ventilation air, and required minimum permanent vent WHAT TO DO IF YOU SMELL GAS: opening, must conform with the National Fuel Gas Open a window. Code (Z223.1) and applicable local building codes. A • Do not try to light any appliance. damper stop clamp is included to maintain the minimum • Do not touch any electrical switch; do not permanent vent opening and to prevent full closure of • use any phone in the building. the damper blade- The chimney damper should be Immediately call the gas supplier from fully opened when burning the log set.The log set is • designed to burn with yellow flames;thus,adequate a neighbor's phone and follow the gas ventilation is absolutely necessary. supplier's instructions. • If you cannot reach the gas supplier, call the Important: To comply with certification, listings,and fire department. building code acceptance, and for safe Installation and service must be performed operation and proper performance, by an NFI Certified or other qualified ONLY Peterson parts and accessories professional installer, service agency, or may be used with this gas log set. the gas supplier. INSTALLER & CONSUMER NATIONAL \ FIREPLACE We recommend that our gas These instructions MUST be retained wSTIRITt hearth products be installed NFI andservicedbyprofessonals with this appliance. ■ who are certified in the U.S.6 by Ihf, the Nation a FlFireplaceGs D Q �' Institute (NFI) as NFI Gaspi A'CERTIFIED Specialists. i •CERTIFICRTI011 • LVTIf16 . 2/0 9/2 019 •TfJTInG •wPECTIon ROBERT H. PETERSON CO. • 14724 East Proctor Avenue • Ci of Industry, CA 9,174kr,NPA � y .��(;f1FPARTMPNjT REV 5 - 1011081109 1 L-A2-013 IMPORTANT - Read This Manual Carefully Before Starting Installation of the Log Set When the log set is burning, the fireplace damper must be fully open.The Peterson Real- Some Available Log Styles: Fyre" gas log set is to be burned only in a fully Charred Series Designer Series vented,noncombustible fireplace with damper and Charred Oak (CHD) Golden Oak Designer Plus chimney free of any obstructions. The fireplace Charred Split(CHS) (RDP) must be designed and approved to burn wood.As Charred Royal (CHB) Split Oak Split Oak Designer Plus with burning natural firewood, the Real-Fyree" log (SDP) set is designed to burn with yellow, smoky flames. Classic Series Woodland Oak (WO) For this reason, it must be adequately vented. If Golden Oak (R) Designer (EXD) adequate ventilation is not provided as detailed Post Oak(PO) Royal English Oak Emberwood (E) Designer (BD) on this instruction, do not use this Real-Fyre® Royal English Oak (B) Heritage Designer(HD) log set. If fumes from the burner emerge into the Mountain Oak (K) White Birch (W) room when the damper is fully open, creating a Twisted Pine (C) Golden Oak Designer(RD6) smell like a smoldering oil lamp, it indicates that the fireplace draft is defective.Check chimney flue for obstructions. Do not operate the log set until FOR YOUR SAFETY the fireplace draft is corrected. Check with the Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other dealer or installer. Do not use firewood with the appliance. gas log set. TABLE OF CONTENTS PARTS LIST 3 IMPORTANT INFORMATION 4 FIREPLACE REQUIREMENTS 4 INSTALLATION 5 INSTALLING THE BURNER 5 LOG PLACEMENT 6 GRANULE, EMBER. AND GRATE PLACEMENT 6 OPTIONAL CHARRED SERIES INSTALLATION 8 LIGHTING INSTRUCTIONS 9 MAINTENANCE & SERVICE 10 OPTIONAL CONTROLS 10 OPTIONAL PETERSON VALVES & SAFETY PILOT KITS* 11 TROUBLESHOOTING YOUR GAS LOG SET TROUBLESHOOTING YOUR GAS LOG SET (Continued) RE�+E n I Eta WARRANTY 14 12/09/2019 ASPS BUILfIN( nFp RTMFv!T REV 5 - 1011081 109 2 L-A2-013 PARTS LIST Before beginning installation, be sure the gas log set is complete by comparing its contents with this PARTS LIST.The RG4-24 set is listed and illustrated.Your parts may differ depending upon the log style and size of the set. Be sure you know the model number and size of your set when ordering replacement or optional parts and accessories. 13 6 glar WM/ 4 —.�. 14 12 5 l' U0' ,, 3 1 .,65i :1(1. 11 10 Sand or vermiculite Glowing embers granules der 8 • r/ ".,, 7 Oi Connector kit IP 9A Item Part No. Description The to g set is No. purchased and 1. RL-24BF Golden Oak front bottom log 24" Pa Gockaged aeporately. Golden Oak log set 2. RL-20BR Golden Oak rear bottom log 20" shown here.Styles 3. RL-1 5TL Golden Oak top log 15" and sizes will vary depending upon the 4. RL-1 5TR Golden Oak top log 15" log set ordered. If 5. RL-9TL Golden Oak top log 9" the log set ordered 6. RL-9TR Golden Oak top log 9" includes placement I instructions;follow Stabilizer clips with screws and nuts those instructions. 7. 400768 (replacement package also includes a damper clamp) 8. DC-1 Damper clamp I 0 9. CK-14-12 Connector kit (with adapters) I 10 EM-1 Glowing Embers (2) 11. CS-12 Select sand granules (natural) or LF-15 Vermiculite granules (propane) I 12. AB-2-29 Fuel injector (natural) I or AM-2-50 Air mixer (propane) 13. SD-24 Fireplace grate 24" or SX-24 Heavy-duty fireplace grate (GX4 log RECEIVD sets) 12/09/201111 14. GG-24 Burner pan, glowing embers 24" 0 with burner size, mode:, andASPEN Note: Values in bold changelog _1 set. nl)!I rnNr.nFpARTMENT — — Replacement parts can be ordered from your local Real-Fyre®dealer. REV 5 - 1011081109 3 L-A2-013 IMPORTANT INFORMATION Important: To comply with certification, listings, and building code acceptances, and for safe operation and proper performance of this log set. use ONLY Peterson Real-Fyre'' parts and accessories. Use of other controls, parts, and accessories that are not designed for use with Real-Fyre`R gas log sets is prohibited and will void all warranties, certifications. listings, and building code approvals, and may cause property damage, personal injury, or loss of life. Check to be sure the fireplace meets venting and construction requirements for the installation of the Real-Fyre'' gas log set (see FIREPLACE REQUIREMENTS section, below). Be sure your gas log set is properly sized for your fireplace. Improper sizing may negatively impact the proper drafting of the fireplace. Additionally, too large a log set will adversely affect the burn and hamper the proper operation of the control system.Too small a log set will diminish the beauty of your hearth setting. Fig. 4-1 below shows the critical dimensions of your firebox.The table below shows log set dimensions. FIREPLACE REQUIREMENTS This Real-Fyre"' gas log set is to be installed only in ( Fig.4-1 Fireplace Dimensions a fully vented, noncombustible fireplace with an open damper.The chimney must be free of any obstructions. The fireplace must be designed and approved to burn wood. Your Real-Fyre log set is designed to burn Rear wicth with yellow, smoky flames. For this reason, it must be adequately vented. Height The fireplace must have a gas-supply line that has been _ ✓ Depth r \ 1 installed by a qualified technician in accordance with all /_ r Front --� local codes.The gas-supply line must be 1/2"minimum width opering interior diameter.If the gas line to the fireplace is longer Note: It is recommenced that complete firebox cimersions(front width, than 20', a larger-diameter line may be necessary. back wall,and height)be obtained to ensure proper sizing. A fireplace screen must be in place when the system Min. Fireplace Dimensions is burning. Provisions for adequate combustion Burner BTU Width air must be maintained. Unless other provisions for size Depth Height combustion air are provided, the screen shall have Front* Rear • NAT. L.P. an opening(s) for introduction of combustion air. 12" 18" 16" 11" 18" 25k 25k Combustion air is adequate when all flames curl into 16/19" 25" 23" 11" 18" 39k 39k the fireplace and away from the screen.When a glass 18/20" 26" 24" 14" 18" 75k 50k fireplace enclosure (door) is used,leave the doors 24" 30" 28" 14" 18" 90k 65k fully open when the system is in operation. 30" 36" 34" 15" 18" 90k 65k Required Gas Pressure: The minimum inlet gas- [36"] 42" 40" 16" 18" 120k 90k supply pressure for the purpose of input adjustment is [42"I 48" 46" 201" 18" 150k 110k 7" of water column (w.c.) for natural gas and 11" w.c. [48'1 54" 52" 201/2" 18" 150k 115k for propane. The maximum inlet gas-supply pressure [so°) ss° 64° 20 " 18" 150k 120k is 10.5" w.c. for natural gas and 13" for propane. ' This required width allows for centering of the log set. Add 4" to front width if the burner is to be installed with a pilot kit. Note: Rear wdth is at corresponding depth. Bracketed E VEC sizes indicate non-certified burner systems. V L� Minimum Free Opening Area of Chimney Damper for Venting(sq.in.) 12/0 9/2019 For Factory-Built Fireplaces* Chimney ASPEN Height 12' 16/19" 18/20" 24" 30' 36' 42' 48' 60' ''NG DEPARTMENT 15'(min.) 16 25 47 57 57 75 94 94 94 20' 14 22 43 51 51 68 85 85 85 30' 13 20 38 46 46 61 76 76 76 _ * For Masonry-Built Fireplaces:add 4 sq. in.to amount shown. REV 5 - 1011081 109 4 L-A2-013 INSTALLATION The damper clamp with hex bolt(Fig.5-1) is provided as a means to prevent ( . '\ full closure of the damper blade.The clamp is easily attached to most damper • blades with pliers or a wrench, and must be permanently installed.The clamp is designed to prevent accidental closure of the damper when installed as illustrated(Fig.5-2 and Fig.5-3).Should the clamp not fit, or fail to provide the ......\ permanent vent opening listed in the table found above, have a permanent stop installed, remove the damper blade, or have I — \ the damper cut to provide the minimum permanent Set screw me opening required. \ ..;\ Imo ii Note: These are minimum damper opening specifications.The damper must be completely Damper clamp P Open acsed opened when operating this gas appliance to 1 Fig.5-1 Fig.5-2 Fig. 5-3 J achieve the best ventilation possible. INSTALLING THE BURNER The Real-Fyre gas log set must be installed by a qualified professional service technician. Instructions must be followed carefully to ensure proper performance and full benefit from the gas log set. Check to be sure the log set is designed and labeled for the type of gas (natural or propane gas) supplied to the fireplace. Fireplace floor must be level,clean, and smooth. WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. REFER TO THE PARTS LIST WHEN FOLLOWING THESE INSTRUCTIONS. If your burner is to be installed with a pilot kit:carefully follow the instructions supplied with your pilot kit for specific gas connection. The burner pan is supplied with an air mixer for propane gas or a fuel injector for natural gas.The air mixer/fuel injector must be used in ALL installations.The air mixer/fuel injector has a precisely sized orifice to ensure only the proper quantity of gas enters the burner.This allows maximum performance and gas conservation. 1. MAKE SURE THE FIREPLACE GAS SUPPLY IS TURNED OFF 2. Locate the gas-supply stub inside the fireplace and remove the cap, if attached (see Fig. 5-4). CAUTION: When removing the cap, make sure the stub does not turn, loosening the connection inside the wall. 3. Attach the small adapter (Item 9C) to the fuel injector/air mixer on the burner pan, using a pipe compound resistant to all gases. Tighten securely. DO NOT REMOVE THE FUEL INJECTOR / AIR MIXER. Then attach one end of the flex connector (Item 9B) to the small adapter.Tighten securely. 4. Place the burner system into the fireplace so the open burner pan faces outward. 5. Locate the grate(Item 13) and attach the stabilizer clips (Item 7)to the 2 outer bars of the grate with screws and nuts.The stabilizer clips should be positioned towards the middle of the bars (Fig. 5-5). Place a clip on each side of the bar. insert the screw, attach the nut, and loosely tighten. Repeat for the other side. 6. Place the grate over the burner pan so the stabilizer clips fit over the back edge of the burner pan to lock it in position. Completely tighten the clips in place. i Fig.5-4 Fig. 5-5 Stabilizer clips on grate STABILIZER BACK GRATE, CUPS WA_L OF FIREPLACE R CEIVE Gas line -4--) \ AllINI 1 /09/201A cap \ \ �Gas supply ASPS; line stub BURNER PANil ING 7n. REV 5 - 1011081109 5 L-A2-013 INSTALLATION (cont.) 7. Center this assembly in the fireplace and place it as far back in the fireplace as possible. Remove Fig. 6-1 - Fireplace valve Flex the grate for the gas connection and granule/ember / connector placement. `ucI 8. Be sure gas to the fireplace is off. Attach the Burne- 1 large adapter (Item 9A) to the gas supply stub Pin E using a pipe compound resistant to all gases. \ Large adapter Tighten securely.Then attach the open end of the flex connector to the large adapter.Tighten securely. Ensure the pan rests level on the fireplace floor after connection. Adjust the pan if necessary. 1 Small 9. LEAK TEST: Use a long-necked butane lighter, or adapter Gas lay a lighted match next to the burner pipe, and supply line carefully turn on the gas supply until the burner ignites.Test at all connections for leaks using the appropriate soapy water solution. If bubbles appear, a leak is present. Turn off the gas and tighten at all connections. Repeat until no leaks are present. If a leak persists, turn off the gas supply and contact the local gas company or dealer. NEVER USE A FLAME TO CHECK FOR LEAKS. Turn off the gas supply prior to proceeding. GRANULE, EMBER, AND GRATE PLACEMENT GRANULE PLACEMENT The granules supplied with the unit are specially selected for use with either propane gas or natural gas.They maximize flame 1 distribution and reduce carbon buildup. Back wall of fireplace 1. Fill the burner pan completely with the granules* (Item 11). Place granules m N. See Fig.6-2. Avoid spilling the granules on the pilot kit(if pan &slope to angle equipped). of pan *Note: Use only select sand for natural gas burners and _ .O burner pan vermiculite for propane gas burners. ••• 2. Slope the granules at the same angle as the burner pan.This is Fig. 6-2 Granule placement important to ensure quiet lighting and even flame distribution. EMBER PLACEMENT Sprinkle the glowing embers (Item 10) lightly and evenly over the entire surface of the granules. Break up any clumps that may have developed during shipment. (For Charred series log sets. refer to OPTIONAL CHARRED SERIES INSTALLATION section.) Important: Do not add any additional embers to this log set.Any additional embers may cause unsafe operation. GRATE PLACEMENT Replace the grate so that the stabilizer clips fit over the back edge of the pan, locking it in position. LOG PLACEMENT CAUTION: Burn hazard. Logs will remain hot for some time after use.You must maintain the -. �VED log layout as shown to ensure proper operation of your log set. If you need towl2�09/2019 reposition any log to maintain the proper layout, use heat-resistant gloves or allo logs adequate time to cool before handling. ASPEN Styles and sizes will vary depending upon the log set ordered.If the log set ordered includes placement 'ARTMENT instructions; follow those instructions. REV 5 - 1011081 109 6 L-A2-013 LOG PLACEMENT (cont.) NOTE: LOGS SUPPLIED SEPARATELY. Log placement is very important for the proper operation of the Real-Fyre®gas log set.Although you have some flexibility in the log arrangement, it is necessary to follow the LOG PLACEMENT instructions carefully to fully enjoy your log set. Follow the steps below, referring r Rear 1 to Fig. 7-1 through Fig. 7-5. Front bottom Stabilizer 1. The second-longest log, the rear log, is placed on Grate bottom clips bg offireplacl e the rear of the grate with the bark of the log facing forward (Fig. 7-1). Center the log left to right (Fig. 7-5, #1). If the log has a heat chamber (a recess in Glowh embers ',... • Stabilizer clip the back), it can face either forward or to the rear. g fits over rear ion top of granules) MCedge of 2. The longest log, the front log, is placed on the front \ `1 burner pan of the grate with the bark facing forward. Center left Granules �Y .O Burner pan to right(Fig. 7-2, #2).If the log has a heat chamber, it -'P —1 should face to the rear. NOTE: Be sure to maintain , Fig. 7-1 a space between the front and rear logs(Fig.7-1). This creates energy efficiency, heat radiation, and reduces carbon buildup. 3. Top logs should be stacked diagonally, with the largest at the bottom (Fig.7-3, #3 & 4), and with spaces between the logs so that the flames are not choked off. Place the smaller logs diagonally across the larger ones (see Fig. 7-4, #5 & #6).The top logs may be moved to achieve desired flame pattern. Some carbon buildup (sooting) may occur where the flames impinge on the logs and should not be a concern unless excessive. If sooting is excessive, rearrange the top logs to reduce flame impingement. Examples of log stacks are shown below. Note: Although log styles may differ in pattern or shape(Fig.7-6),layout is essentially the same.Adequate spacing between the logs is NECESSARY and MUST be maintained for best performance. STEP 1. Place the second-longest .- log to the rear. 0 Fig. 7-2 1•�` i' ` - © *44 i' `.. Fig. 7-5 STEP 2. Place the longest Alternative examples of log layout (Split Oak log at the front.ir set shown). Note the space between the logs. J M STEP 3. Place the largest top logs STEP 3 (cont.) Place the smaller top logs across the bottom logs. across the other logs. 1 < < Fig. 7-3 Fig. 7-4 3 - - U. , OY amp _ .. . 11 i simik•- v, --Ir • . Knotholes go to the front (Note the gaps between the logs.) l or back as desired. Note: 24" Golden Oak(R-24) shown 1— Royal English Split Oak Woodland" .y-- -4 i. Oak Designer .. 0 ._-. Designer Plus - ` #,. Oak I-, - CE VEE •-..'"*--.W'4*--,,,t**_ ., _ , *11# ''- �{ .�.. ,� .® ri. .' /09/20_9 .41 '''`''�" ''''`r-' 1' Fig. 7-6 - Recommended log patterns ASPEN ILI DIHC n-T�Tr.EN1 REV 5 - 1011081109 7 L-A2-013 OPTIONAL CHARRED SERIES INSTALLATION GLOWING EMBERS PLACEMENT Note: Optional Charred Series log sets are supplied with an ember screen (Fig. 8-1). Fig. 8 1 - ? Ember screen Attach the ember screen to the burner by slipping (supplied with • optional Charred it onto the back edge (center left to right) with the Series log sets) perforated section facing toward the back fireplace wall (Fig. 8-1). Cover the surface of the ember Fig. 8-2 screen with the Glowing Embers (Fig. 8-2). For best ,— glowing performance, they should be applied evenly 'IVINA and pulled slightly apart so the fibers are somewhat loose. (It is not necessary to pile the entire bag of the Glowing Embers. More Glowing Embers may be added after completion of the entire installation). LOG PLACEMENT Log styles and sizes will vary depending upon the Charred Series log set ordered. CHARRED SPLIT (CHS) layout shown. Place the long bottom rear log (Log#2)on the back The charred sections should be over the opening of the grate with the flat featureless side facing the between the front and rear logs (Fig. 8-4). rear of the fireplace.The two sections of the front Place the small top charred logs (Logs #5 & 6) so log (Logs #1 A & 1 B) are placed on the front of the they rest over the charred sections of the front bottom grate with the charred sections facing each other log sections (Logs # 1 A& 1 B) and on the two curved and approximately 1 inch apart at the top (Fig.8-3). logs (Logs #3& 4) (Fig. 8-5). Slide the logs to the front of the grate. Finally, place the curved top charred log (Log #7) to Note: Be sure to maintain a space between the rest on the two top logs at rear, but not encroaching front and rear logs (Fig. 8-3).This creates into the space between rear and front logs (Fig.8-6). energy efficiency and heat radiation, and reduces carbon buidup. Note: The additional top log(Log#7) is not available with 18" log sets. Place the two curved logs (Logs#3& 4) so that one end rests on each front log section (Logs #1 A& 1 B) and the other end rests on the rear log (Log #2). Fig. 8-3 Fig. 8-4 LOG #2 `•. _ i� - -� ' LOG#1 A LOG#1 B. " .. MAINTAIN A SPACE IN THE CENTER OF • ECEIVED THE LOGS AT ALL TIMES Fig. 8-6 Fig. 8-512/09/2019 _ Log #7 ASPEN ;e 1ILDING DEPPRTMEN • A REV 5 - 1011081 109 8 L-A2-013 LIGHTING INSTRUCTIONS Before operating your gas log set: 1. Be sure your fireplace is free from flammable liquids or combustible materials. 2. Be sure your damper is open. 3. Smell all around the gas log set for the odor of escaping gas. IF YOU SMELL GAS, FOLLOW THE INSTRUCTIONS ON P. 1. If your gas log set is operated by the fireplace valve: 1. Lay a lighted long-stem match on the surface of the embers near the gas inlet(do not hold the match in your hand) or use a lighted long-necked butane lighter (Fig.9-1). 2. Slowly turn the fireplace remote valve to the ON position.Your log set should light. 3. If the log set does not light before the match goes out, immediately turn the valve to the OFF position. 4. Wait approximately five (5) minutes to clear out any as and repeat steps 1-3 above. 5. If your log set fails to light again, turn the valve to the OFF :,;: ;; ; : position and contact your dealer or gas supplier. ; ,' tl• 6. To extinguish your gas log set,turn the valve to the OFF position. Be sure the valve is turned fully off to avoid any Fig. 9-1 gas leakage. \ Apply match -then turn on gas j If your burner is operated by a pilot kit: 1. Carefully follow the lighting instructions supplied with your pilot kit for the steps to ignite the burner. RECEIVED 12/09/2019 ASPEN BUILDING DEPARTMENT REV 5 - 1011081109 9 L-A2-013 MAINTENANCE & SERVICE Maintenance Once installed and operating properly, your Real-Fyre gas log set will require regular maintenance. You should inspect your log set and controls (where installed) for the following: 1. Excessive sooting - Some sooting of your log set is normal, adding to the appearance of burned wood. If excessive sooting accumulates, clean the logs using any of the following options: Option 1. Spray the logs with clean water when they are being burned and hot. The soot will lift off and burn off. Option 2. Brush the soot off with a stiff brush when the logs are cold. Do not use water or soot cleaners at the same time as brushing the soot off. 2. Moisture may cause the granules and Glowing Embers in your burner pan to settle.To improve the burn, follow these tips. a. Settling of sand (or vermiculite)- Using a screwdriver or flat-blade knife, carefully stir the granules, loosening the material. Clear up any spills. b. Embers - Break up any clumps that may have formed, then redistribute the embers on the granules. 3. Debris around the control (where used) - Inspect control and pilot to be sure it is free of dirt or debris. Service While some minor service conditions may be handled by the owner of the log set, it is recommended that a qualified professional service technician be called to maintain and service the gas log set and any installed control system.TheTROUBLESHOOTING section of these instructions serves as a guide for ensuring optimum performance of your gas log set. OPTIONAL CONTROLS THIS UNIT COMES WITHOUT A VALVE INSTALLED. IT MAY BE CONNECTED DIRECTLY TO AND OPERATED BY YOUR FIREPLACE VALVE. Alternatively, your Real-Fyre" gas log set may be operated using a number of optional Peterson control systems (see below). Peterson control systems are engineered to provide convenient, safe, and reliable operation of your gas log set. For safe operation, proper performance, and to comply with safety standards and certifications, use only Robert H.Peterson Company control systems,parts,and accessories with your Real-Fyre' log set. If you have purchased a valve separately, unpack your Peterson control system and check the PARTS LIST provided with your control to be sure all parts are included. Peterson Control Systems Manual On/Off Systems RERECEIVEDRECEIVEDAV-17 (knob) or AV-18(rod handle) Manual On/Off, match lit, no pilot Manual Safety Pilot Systems 12/09/2019 SPK-20 (knob) or SPK-21 (rod handle) ..... Standard Pilot ASPEN SPK-26 . ............... Low-Profile Valve BUILDING DEW- Remote Systems (APK-11, EPK-01) Available Accessories Toggle Switch,WS-1 Wall switch,WS-2 Wall timer,WCS-1 Wood Chip switch, RR-1 A Remote, RR-2A, Deluxe Remote, PC-105 Pine Cone Remote. Variable Remote System (APK-150, APK-15,APK-17) Available Accessories WS-3 Wall switch,VR-1 A Variable Flame-Height Remote.VR-2A Deluxe Variable Flame-Height Remote. REV 5 - 1011081 109 10 L-A2-013 OPTIONAL PETERSON VALVES & SAFETY PILOT KITS* Note: For all valves and safety pilot kits shown on this page,carefully follow the instructions supplied with your safety pilot kit for steps to assemble and install it on the burner pan and test for leaks. *Available from your local Real-Fyre® dealer "APK-11 Fuel injector — 7SPK-20 Fuel injector_ rConnectors / Main burner Burner Hearth Main Burner pipe pan P adapter burner pan $ ° " _. Gas- hi,. supply , 1. line ' '�� . . `71 - tA APK-11 I Connector � =r<—Gas- remote SPK supply ready Adapter 1 valve line Fireplace floor valve Hearth Fireplace floor adapter Note: Heat shield is not Note:Heat shield is not 'j shown,but must shown, but must " ' SPK 20 be in place when O�� be in place when ' / % li Fig. 11-4 operating your operating your ��`. g glass burner. J AV Vet �fi1� ' Fig. 11-1 glass burner APK-15 Fuel injector SPK-26 Fuel injector Connector Burner Burner Main burner pan Connector Main burner pan pipe pipe Adapter Gas- APK 15 t s f Adapter upp remote I linely SW-26 safety Hearth safetyHearth Fireplace floor valve adapter Fireplace floor valv adapter „-• Note:Heat shield is not 00- Note:Heat shield is not Sp., shown, but must ��. shown, but must ��. SPK-26 be n place when S��� be in place when Valve operating your APK-15 ;, operating your . Fig. 11-5 glass burner. Valve `' Fig. 11-2 glass burner. rAPK-1 7 Fuel injector (AV-1 7 Fuel injector Flared adapter Connector AV-18 Burner pan • Burner Connector _1; Adapter Main burner pan n • tiZ, pipe Gas-supply fi line J Gas- supply valve 1Heart supply Fireplace floorON/OFF line valve APK-17(M)(P)valve Fireplace floor adapter �d�+lf Note: Heat shield is not Fig. 11-7 ` °� APK valve shown.but must RECEIVED :1 be in place when operating your ik pass burner. 12/0 9/2 019 , Fig. 11-3� ASPEN 13Ul l IO IIEPARTIIAFNT REV 5 - 1011081109 11 L-A2-013 TROUBLESHOOTING YOUR GAS LOG SET SYMPTOM CAUSE SOLUTION 1 . Excessive smoking and A. Poor draft or downdraft A. Check for chimney blockage. sooting Be sure chimney is at least 3' taller than anything within 10' of it in all directions. If not, consult a chimney sweep. Chimney cap or fan may help. Under severe conditions, you may need to open a window near the fireplace about 1" to 2" when burning the log set. B. Improper burner for gas used B. Use only a natural-gas set with natural gas. Use only a propane-gas set with propane gas. C. Damper closed C. Open the damper fully when operating the gas log set. D. Improper log placement D. Be sure the bottom logs are spaced at least 3' apart. Top logs should be placed to minimize flame impingement. E. Air mixer on propane set is E. Open the air mixer completely. closed 2. Low flame A. Incorrect log set for type of gas A. Consult your dealer for proper used set. B. Insufficient gas supply B. Other gas appliances may be competing for gas supply. Consult installer or plumber. Orifice size is based upon 7" w.c. pressure for natural gas and 1 1" w.c. pressure for propane gas. Plumbing must supply adequate pressure. C. Blockage or kink in connector C. Cleanoutblockage.lfconnector kit, plumbing, or burner orifice kit is kinked, replace it. D. Valve not fully open D. Open valve fully. RECEIVED 12/09/2019 ASPEN BUILDING DEPARTMENT REV 5 - 1011081 109 12 L-A2-013 TROUBLESHOOTING YOUR GAS LOG SET (Continued) SYMPTOM CAUSE SOLUTION 3. Uneven flame distribution. A. Clogged or blocked portholes A. Portholes can be cleared of (Lower at one end of the foreign object by running a wire burner) through them. B. Insufficient gas pressure and/or B. Consult installer or plumber. supply (See solution 2b.) C. Granules may be packed down C. Loosen granules around burner too tightly pipe by running a kitchen knife along both sides or pipe. Even out granules in burner pan. D. Auxiliary shutoff valve partially D. Open valve fully.Usually,you will closed find this along the wall 3'from the fireplace. 4. Flame at air mixer A. Clogged or blocked portholes A. Portholes can be cleared of (For propane units) foreign objects by running a wire through them. B. Insufficient gas pressure and/or B. Consult installer or plumber. supply (See solution 2b.) C. Granules may be packed down C. Loosen granules around the too tightly burner by running a kitchen knife along both sides of the pipe.Be sure vermiculite (not sand) is used with an air mixer. D. Excessive gas pressure D. Contact your gas supplier. RECEIVED 12/09/2019 ASPEN BUILDING DEPARTMENT REV 5 - 1011081109 13 L-A2-013 WARRANTY PETERSON VENTED GAS LOG SETS LIMITED WARRANTY All Peterson gas logs are WARRANTED for as long as you own them (lifetime). All Peterson burner assemblies are WARRANTED for TEN(10)YEARS. SPK-26 controls are covered by a THREE(3)YEAR"All Parts"Warranty. All other Peterson valves, pilots, and controls are covered by a ONE (1)YEAR Limited Warranty(excluding batteries). PLEASE KEEP A COPY OF YOUR SALES SLIP FOR PROOF OF PURCHASE This warranty applies to the original purchaser and to single family residential use only. It commences from date of purchase,and is valid only with proof of purchase. This warranty does not cover parts becoming defective through misuse,accidental damage,electrical damage,improper handling, storage,andior installation.Product must be installed(and gas must be connected)as specified in the instructions or operator's manual,by a qualified professional installer.Accessories,parts,valves. remotes,etc.,when used must be Peterson Co.product. This warranty does not apply to rust,corrosion, oxidation,or discoloration.unless the affected component becomes inoperable.It does not cover labor or laoor-related charges. This warranty specifically excludes liability for indirect,incidental,or consequential damages.Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion may not apply to you.This warranty gives you specified legal rights,and you may have other rights that may vary from state to state. For additional information regarding this warranty,or to place a warranty claim. contact the R.H. Peterson dealer where the product was purchased. TO REGISTER YOUR PRODUCT ONLINE GO TO: WWW.RHPETERSON.COM, AND CLICK ON PRODUCT REGISTRATION.THANK YOU FOR YOUR PURCHASE. RECEIVED 12/09/2019 ASPEN BUILDING DEPARTMENT Quality Check Date:_ Burner Orifices Nat. L.P. Leak Test: Model#: Main: Burn Test: Serial#: Other: Gas Type: Nat. / L.P. Air Shutter: Inspector: Robert H. Peterson Co. • 14724 East Proctor Avenue •City of Industry, CA 91746 14