Loading...
HomeMy WebLinkAboutFile Documents.728 E Hopkins Ave.0186.2019 (10).ARBK •TENMAT FF109-350 FIRE PROTECTION SOLUTIONS 1 Hour Fire Rated Light Cover Technical Product Specification _, 15" � fir j I 4`e I11•ii FF109-350 DOME 0 • t S 5/8. Model Inside Outside The FF109-350 is the larger version of Number Height Diameter I the FF109-300 and suitable for lights up to 8". FF109-350 10 3/8" 17" Performance Data r_ Both covers are made out of the same intumescent material and exhibit For Use: excellent thermal and acoustical • Warnock Hersey- Intertek certified to maintain the fire rating (1 hour) of fire-rated floor/ceiling assemblies. insulating properties. The FF109-350 has an inside height of W 10 3/8" and a diameter of 15" to fit the c ~m us most common recessed light housings. Intertek Tested to ASTM E119 UBC 7 1 NFPA 251 ASI A2.1 General Information PBenefits: :; • 60 minute protection. H ii 14ti • Fits most popular recessed light fixtures. Z • For use with recessed incandescent, fluorescent or LED light fixtures. _ 1 1%4- i eater ,:•• Can be used in L500 floor/ceiling assemblies. I■ ■■� ■ , 111111 Lightweight(approx. 2.5 Ibs). • Easy Installation - can be fitted in seconds- no screws, drilling or additional sealant required. I • Flexible material enables the cover to be fitted around Jar obstacles or retro-fitted. rear imar • Enhances the acoustic protection of the ceiling. �m �m NMI UN • Maintenance free. ■ �;hili;; • - P • ^�. TENMAT Inc. 23 Copper Drive Newport, DE 19804 T: 302-633-6600 F: 302-633-6838 E: info@tenmatusa.com 0 TEN MAT Technical Product Specifications Model Inside Inside MODEL FF109-350 Number Height Diameter FF109-350 10 3/8" 15" Performance Data 171 + For Use: • Warnock Hersey- Intertek certified to maintain the fire 1511 rating (1 hour)of fire-rated floor/ceiling assemblies. • .4• c ~m• US • • 0 ••• Intertek g % 11` Tested to ASTM E119 / 0 UBC71 0 0 NFPA 251 0 ASI A2.1 0 0 FF109-350 DOME 110General Information 0 0 Benefits: • 4 _ 5/8" • 60 minute protection. • Fits most popular recessed light fixtures. • Can be used in L500 floor/ceiling assemblies. • Lightweight(approx. 2.5 Ibs). • Easy Installation - can be fitted in seconds- no screws, drilling or additional sealant required. • Flexible material enables the cover to be fitted around O obstacles or retro-fitted. } • Enhances the acoustic protection of the ceiling. Ventilation Holes • Reduces heat loss through the fixture. A A • Significant energy cost savings. J. • Maintenance free. Manufactured By Tenmat Inc 23 Copper Drive RECEIVED r Newport, DE 19804 Phone: (302) 633-6600 10/21/2 019 Fax: (302) 633-6838 ASPEN Email: info@tenmatusa.com BUILDING DEPARTMENT www.tenmatusa.com Report prepared for: Spec Direct(Free User)on 11/6/2015 7:45:59 AM DIRECT Intertek LISTING INFORMATION OF Tenmat Firefly 109 Recessed Light Cover SPEC ID: 29353 Tenmat, Incorporated 23 Copper Drive, Unit#3 Newport, DE 19804 This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement,for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety.Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek.The observations and test results in this report are relevant only to the sample tested.This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. RECEIVED 10/21/2019 ASPEN BUILDING DEPARTMENT Tenmat,Incorporated 129353 Rev:Mar 29 2013 6:04PM l Uncontrolled Copy Page 1 of 5 Report prepared for: Spec Direct(Free User)on 11/6/2015 7:45:59 AM DIRECT The Firefly 109 is a shell constructed of a mineral fiber-matrix which has an intumescent property. The product is designed to protect ceiling openings that are made to accommodate recessed lighting fixtures in rated floor- ceiling construction. The product is placed over the light fixture on the top side of the ceiling, and rests on the ceiling mambrane. The product is available in two sizes and is constructed with vent slots that can be used to accommodate power source cable. Attribute Value Criteria ASTM E119 (2012) CSI Code 07 20 00 Thermal Protection Intertek Services Certification Listed or Inspected LISTED Listing Section OTHER PRODUCTS Report Number 16683-1, 16683-115827 Spec ID 29353 RECFNED 10/21/2019 ASPEN BUILDING DEPARTMENT Tenmat,Incorporated 1 29353 Rev:Mar 29 2013 6:04PM l Uncontrolled Copy Page 2 of 5 Report prepared for: Spec Direct(Free User)on 11/6/2015 7:45:59 AM DIRECT DRAWING INDEX TEN/FCA 60-01/OPL LC 101 RECEIVEr 10/21/2019 ASPEN BUILDING DEPARTMENT Tenmat,Incorporated 1 29353 Rev:Mar 29 2013 6:04PM l Uncontrolled Copy Page 3 of 5 Report prepared for: Spec Direct(Free User)on 11/6/2015 7:45:59 AM DIRECT TEN/FCA 60-01/OPL LC 101 Luminary Covers Design No.LC 101 LUMINARY COVERS F-Rating-1 hr 1A 2 1B fr 1C 1. FLOOR CEILING ASSEMBLY: embedded in first layer of compound Constructed in the manner as specified over joints in gypsum wallboard. below: 2. FIXTURE PROTECTION COVER: A. Plywood subfloor: Min. 5/8 in. thick Constructed of a proprietary high- SYP plywood. Long dimension of temperature fiber matrix and having an panels,or face grain of plywood,to be intumescent feature.Two sizes of covers are perpendicular to joists(1B)with joints recognized within this Listing. The smaller staggered. Plywood is secured to top cover has a base diameter of 14-1/2 in.and side of joist assembly with min.No. 6, an overall height of 9 in. The larger cover 1-7/8 in. long bugle-head drywall has a base diameter of 17 in.and an overall screws, spaced max. 16 in. OC. along height of 11-1/4 in.Covers are centered over joists. openings up to 8 in.in diameter that are cut B. Lumber Joists:Parallel nom.2 X 10,or into the gypsum ceiling for the purpose of deeper, lumber joists spaced a min. 16 installing a recessed fixture.The cover may in.o.c.and a max.of 24 in.OC. be slit to fit over obstructions in order to allow the cover to fit flush to the gypsum C. Gypsum Wallboard:Nom. 5/8 in.Type wallboard. When this occurs, caution is to X gypsum wallboard is secured to the be used to not damage the cover.The covers underside of the lumber joists(1B)with may be installed in the floor with the min. No. 6, 1-7/8 in. long bugle-head following provisions: drywall screws, spaced max. 6 in. OC. along perimeter and on joists in the • Max.1 opening within 16 sq.ft.area. field. Apply vinyl or casein, dry or ' Min.o.c.fixture spacing of 40 in. premixed joint compound to face layers within same truss cavity. • Min.center-to-center of gypsum wallboard in two coats to all fixture spacing of exposed fastener heads and gypsum 40 in.for adjacent truss cavities. wallboard joints. A min. 2 in. wide RECEIVED paper, plastic, or fiberglass tape is L��/ 10/21/2019 Revised March 5,2004 ©Omega Point Laboratories,Inc. ASPEN BUILDING DEPARTMENT Tenmat,Incorporated 1 29353 Rev:Mar 29 2013 6:04PM l Uncontrolled Copy Page 4 of 5 Report prepared for: Spec Direct(Free User)on 11/6/2015 7:45:59 AM `C DIRECT TEN/FCA 60-01/OPL LC 101 (page 2 of 2) Luminary Covers • A min. 1/4 in. gap space must be 3. RECESSED FIXTURE:(Not Shown) maintained between the top of the cover Installed in accordance with manufacturer's and the underside of the subfloor(IA). instructions.The fixture can be installed in Listed Manufacturer: an opening having a max.diameter of 8 in. The fixture must be secured to the framing Tenmat,Ltd. of the floor,and may not be supported by Fibrous Fiber Sating the gypsum wallboard.Electrical wiring leading to and from the fixture may FF109 Intumescent Fixture Protection penetrate the cover.When this occurs, Cover caution is to be used to not damage the cover,and the wiring is to fit snugly through any opening. RECEIVED 10/21/2019 ©Revised March 5,2004 Omega Point Laboratories,Inc. ASPEN 9UJILDING DEPARTMENT Tenmat,Incorporated 1 29353 Rev:Mar 29 2013 6:04PM l Uncontrolled Copy Page 5 of 5 TTENMAT FF109-350 FIRE PROTECTION SOLUTIONS 1 Hour Fire Rated Light Cover � Hanger bars of the light fixture shall be screwed to the joists in D r addition to the tabs being hammered into the joists, following the lightCL CDmanufacturer's installation instruction. 4-1 Place Tenmat FF109 cover over the fixture. 0 CNI Slit the cover to fit over the hanger bars of the fixture. i Z a Cut four slits with a size up to 1" max.CD Cl) The wire can be fed through one of the cover vent holes located at N the top. C�+ Follow the light manufacturer instructions to make proper a) connections. sF 0 Put the cover on top of the fixture. Check for secure fit, and make z sure the cover overhangs the hanger bars. Q The FF 109 Light Cover must fit flush with the back surface of the drywall board. 4-11 Ensure the cover fits your chosen WARNING: BE SURE THE ELECTRICITY TO THE SYSTEM YOU ARE WORKING ON IS TURNED OFF;EITHER THE FUSE REMOVED OR THE CIRCUIT BREAKER SET AT OFF. recessed light fixture. CONTAINS STONE WOOL INSULATION FF10.9-350 Overall Dimensions: Stone fibers may cause temporary mechanical irritation to the skin,throat,nose and eyes. • Inside Diameter 15" FIRST AID Skin • Inside Height 10 3/8" If irritation occurs,do not rub or scratch. Rinse under running water prior to washing with mild soap and water.Consult a physician if irritation persists. Throat and Eyes If irritation occurs,flush eyes with water and/or drink water to clear throat. Do not rub the eyes.Consult a physician if irritation persists. PRECAUTIONS • Wear long sleeve,loose fitting clothing,gloves and eye protection Wins • For additional information,refer to the Material Safety Data Sheet(MSDS). C US 10/21/21 ASPEN, Intertek BUILDING DEPAR TENMAT Inc. 23 Copper Drive Unit 5 Newport, DE 19804 T: 302-633-6600 F: 302-633-6838 E: info@tenmatusa.com