HomeMy WebLinkAboutFile Documents.728 E Hopkins Ave.0186.2019 (13).ARBK 11 ity Series ØR1Y` City Series CV40E Gas Fireplace Model CV40E-NG11 CV40E-LP11 i Fuel Type Natural Gas Propane Minimum Supply Pressure 5"W.C.(1.25 kPa) 11"W.C.(2.73 kPa) Manifold Pressure-High 3.8"W.C.(0.94 kPa) 10.5"W.C.(2.62 kPa) , Fy'', Manifold Pressure-Low 1.1"W.C.(0.27 kPa) 2.9"W.C.(0.72 kPa) _ _._ 4AOrifice Size-Altitude 0-4500 ft. #42 DMS #53 DMS Minimum Input 15,500 BTU/h 15,500 BTU/h Altitude 0-4500 ft.(0-1372m) (4.54 kW) (4.54 kW) _..� d.- Maximum Input 28,500 BTU/h 28,500 BTU/h _ Altitude 0-4500 ft.(0-1372m) (8.33 kW) (8.33 kW) Vent Sizing 4"Inner/6-5/8"Outer 4"Inner/6-5/8"Outer - - -�(c 4 CSA P.4.1 55.23% 56.06% '9X #-- 0 64"[171mm] - 21 7 " 0 4" [556mm] [102mm] • . J — L _ E < 1—I� E • 1 — N to I 40" [1016mm] 18 16 _ 46 4" _ [475mm] [1175mm] 17_ 16 -_ �I00 E [449mm] II I I. .I 1 Ai 71 o . . ECU 1 _ MICE �� �,I� Crl M _ M M W c Its E M `� CC) W N CEO ❑ . . @ ® . . � MMITI oIN co EE —ram ' N �� ' 1 1 I. I 1 1 43" [1091mm] RECEWED 07/31/2019 ASPEN BUILDING DEPARTMENT ��REFIGENCY® City Series TS CV40E-11 Gas Fireplace CLEARANCES CV40E The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fires is failure to maintain required clearances(air space)to combustible materials.It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions. Clearance:single sided Dimension Measured From: _ Flue Clearances to Combustibles A:Mantel Height(min.) ** Top of Fireplace Opening Horizontal-Top 3" B1:From Floor Min.0" Bottom of Fireplace Opening Horizontal Side 2" B2:Opening Height 15-1/16"(383mm) Bottom/Top of Fireplace Opening Horizontal Bottom 2" Vertical 2" C:Sidewall(on one side) 8-1/2"(216mm) Side of Fireplace Opening D:Mantel Depth(max.) ** Passing through wall/ floor/ceiling - when 1-1/2" E:Alcove Width 84"(2134mm) Sidewall to Sidewall(Minimum) firestop is used. F:Alcove Depth 36"(914mm) Front to Unit(Maximum) G:Ceiling 37-1/2"(953mm) Top of Fireplace Opening (in front of fireplace) H:Convection Air Outlet * Top of Enclosure J:Convection Air Outlet Opening Offset 0-3"(76mm) Max.offset from top of chase enclosure K:Chase Enclosure(Min.) 63"(1600mm) From base of unit/floor L:Clearance to Sprinkler Head(Min.) 36"(914mm) Perpendicular from chase grill Hearth _ 0" No hearth required **See mantel clearances chart on the next page. n minimum of 120 square j // inches of open area,not ' lower than 3"from top of ._.rinkler enclosure,required for all / L installations �///```���� D — Chase grill A C-,. Side view e� B� Alrift.•-- The HeatWave Duct Kit has rHeat Wave different clearance and framing requirements,check the HeatWave E >11 manual for details. Caution Requirements The top,back and sides of the fireplace are defined by standoffs.The metal ends of the standoff may NOT be recessed into combustible construction. WARNING R • E 9 - E D Fire hazard is an extreme risk if these clearances(air space)to combustible materia s are not Alcove adhered to.It is of greatest importance that this firepla q n5I (ept •2 019 system be installed only in accordance with these in r i sL. ASPEN BUILDING DEPARTMENT ØRIcy CV40E-11 Gas Fireplace MANTEL CLEARANCES CV40E Combustible mantel clearances from top of front facing are shown in the diagram on the right. 14 12 10 8 6 4 2 0 IIIIIIIIIIIIIIP 26— 20= 1/2"Drywall,wood,wood panel,etc. 10- - 12"(305mm) I I 9" ° r ,. � • L J • 5-1/8" 1 — 0 A To Bottom of Top of Fireplace Fireplace Opening 15-1/16" Opening 0 • — n u• .l n MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram: CV40E A A t I I ► MANTEL LEG ' _ • ► Ipiql Allowable mantel leg projection a 8-1/2" A I RECEIVED 07/31/2019 ASPEN BUILDING DEPARTMENT *REGENCTS Y® II:=1 CV40E-11 Gas Fireplace FRAMING DIMENSIONS CV40E NOTE: Framing may be constructed of combustible material(ie.2 x 4)and does not require steel studs. Framing Description CV40E Dimensions A Framing Height 37-3/8"(949mm) B Framing Width 46-3/4"(1187mm) C Framing Depth 19"(483mm) D Minimum Height to Combu 63"(1600mm) E Corner Wall Depth 55"(1396mm) F in_ Corner Facing Wall Width 77-3/4"(1974mm) G Vent Centerline Height 56-1/4"(1429mm) I Gas Connection Opening Height 2"(51mm) .1 1- 'S I ■-.e r K Gas Connection Inset 13"(330mm) Gas Connection Opening Width 3-1/2"(89mm) Maximum material Note: A combined minimum of dimensions 2"x 4" for 120 square inches of open area Header studs(installed is required for the convection on edge and flat) air outlet to cool the enclosure. Ensure clearances for Convection — — _ — Air Outlets are met. —See clearances CV40E (single — �/ O --A Msided) in this manual as there are different methods as to how a this can be achieved. ■■■■m l au . : 1 G A a CM1 II II I I I II I B Finished Fc C \111 -'Illlillllll 1flI II r� MM, Note: This appliance must be installed on a solid surface such as a plywood floor which must ‘ be the full width and depth of the MIL I ■appliance. ILi :...�;_,,ll I�n��n i 1 lemiew L A- nommIMMImmen ,, F �, RECEIVED 07/31/2019 ASPEN BUILDING DEPARTMENT ØRIcy CV40E-11 Gas Fireplace VENTING INTRODUCTION The CV40E uses the "balanced flue" technology Co-Axial system.The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney. Note: These flue pipes must not be connected to any other appliance. The gas appliance and vent system must be vented directly to the outside of the building,and never be attached to a chimney serving a separate solid fuel or gas burning appliance.Each direct vent gas appliance must use its own separate vent system.Common vent systems are prohibited. VENTING ARRANGEMENT FOR HORIZONTAL TERMINATIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations,using one 90°(two 45°elbows equal one 90°elbow). Note:Must use optional rigid pipe adapter(Part#510-994)when using Rigid Pipe Venting Systems. Horizontal (Feet) 0 2 4 6 8 10 12 14 16 18 20 18 � I \ I I I /\JL- I I I 16 I I I I I I I I I I I I I I I 14 I I I I I I , , Vent Restrictor I I on Set 2 I I U I I � I I I I I I 0 1 I _-45 I I u_ I I I Factory Set No Restrictor 8 I I I I '67 I I I I I I I I To U 6 - 0 � I I I 4 f It ♦ 2 56-1/4"(1429mm) Minimum Height Requirement 0 18W `a VENT RESTRICTOR SETTING: Vent restrictor factory set at Set 0. Refer to the"Vent Restrictor Position"section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 2 if required. Note: For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum continuous vent length of up to 10 feet. If longer runs are required,rigid pipe must be used. • Maintain clearances to combustibles as listed in"Clearances"section • Horizontal vent must be supported every 3 feet. RECEIVED • Firestops are required at each floor level and whenever passing through a wall. • A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes. • Flex system can only be used up to 10 feet-otherwise rigid venting must be used. 0 7/31/2 019 ASPEN BUILDING DEPARTMENT 4REQcY ® II=IIPW CV40E-11 Gas Fireplace HORIZONTAL TERMINATIONS RIGID PIPE 4" X 6-5/8" The diagrams below show examples of horizontal termination arrangements using one,two,or three 90°elbows(two 45°elbows equal one 90°elbow). 1. A maximum of three 90°elbows are permitted. 2. Minimum distance between elbows is 1 ft.(305mm). • Maintain clearances to combustibles as listed in the"Clearances"section. • Horizontal vent must be supported every 3 feet. • Firestops are required at each floor level and whenever passing through a wall. • Must use optional rigid pipe adaptor(Part#510-994)when using rigid pipe vent systems. • A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes. • Flex system can only be used up to 10 feet-otherwise rigid venting must be used. HORIZONTAL VENTING WITH TWO(2)90°ELBOWS HORIZONTAL VENTING WITH THREE(3)90°ELBOWS One 90°elbow=Two 45°elbows. One 90°elbow:Two 45°elbows. Option V H +H1 Option V H V+V1 H+ H1 A) 1' Min. 2' Max. With these options, With these options, maximum total pipe length A) 1' Min. 1' Max. 2' Min. 2' Max. max. total pipe B) 2' Min. 4' Max. is 30 feet with minimum B) 1' Min. 2' Max. 3' Min. 3' Max. lengthis30feetwith C) 3' Min. 5' Max. of 6 feet total vertical min.of 12 feet total and maximum 8 feet total C) 2' Min. 2' Max. 5' Min. 4' Max. vertical and max.9 D) 4' Min. 6' Max. horizontal. D) 3' Min. 2' Max. 7' Min. 5' Max. feet total horizontal. E) 5' Min. 7' Max. Please note minimum 1 E) 4' Min. 3'Max. 9' Min. 6' Max. Please note min. 1 F) 6' Min. 8' Max. foot between 90°elbows F) 5' Min. 4' Max. 10' Min. 7' Max. foot between 90° is required. elbows is required. Restrictor Set 0-Factory Setting G) 6' Min. 5' Max. 11' Min. 8' Max. H) 7' Min. 6' Max. 12' Min. 9' Max. Restrictor Set 0-Factory Setting HI01 H H1 - Vt �,. H V ^ . v ",""4 41i:i %Ss, ill>. "--741. \\% RECEIVED 07/31/2019 ASPEN BUILDING DEPARTMENT !Mr ØRIcy CV40E-11 Gas Fireplace VENTING ARRANGEMENT FOR VERTICAL TERMINATIONS VERTICAL VENTING WITH STRAIGHT VERTICAL VENTING AND OR WITH A MAX.OF TWO(2)90°ELBOWS(1 -90°=2-45°) The shaded area in the diagram shows all allowable combinations Horizontal(Feet) of straight vertical and offset to vertical terminations,using two 0 2 4 6 8 10 12 14 16 l8 90°elbows,with Rigid Pipe Venting Systems. I I 1 1 I I I I I I I 1 1 1 1 1 1 Two 45°elbows equal to one 90°elbow. 40— • Vent must be supported at offsets. — • Minimum distance between elbows is 1 ft.(305mm). 11 • Maintain clearances to combustibles as listed in the 36— "Clearances"section. • Horizontal vent must be supported every 3 feet. 34— N • Firestops are required at each floor level and whenever passing through a wall. • Must use optional rigid pipe adaptor(Part#510-994)when1111/11114144 _ using rigid pipe vent systems. �•'• Vent Restrictor on Set 3 • Refer to the"Vent Restrictor Position"section for details on 28— how to change the vent restrictor from the factory setting of Set 0 through to Set 3 if required. 26— �. 24 22— CU CU - i L t 20— i Vent Restrictor on Set 2 _0 E ____+ N To• 18 — r N > > 16— Vent Restrictor on Set 1 10— 8— 6— EN 4 --a --1 , I 77t. 2— • N s 0 --a< Div. RECEIVED Minimum length of pipe between elbows 12"(305mm) 07/31/2019 ASPEN BUILDING DEPARTMENT 4REQcY ® - - CV40E-11 Gas Fireplace VERTICAL TERMINATIONS RIGID PIPE 4" X 6-5/8" • Two 45°elbows equal to one 90°elbow. Maximum of six 45°elbows allowed. • Vent must be supported at offsets. • Minimum distance between elbows is 1 ft.(305mm). • Maintain clearances to combustibles as listed in the"Clearances"section. • Horizontal vent must be supported every 3 feet. • Firestops are required at each floor level and whenever passing through a wall. • Must use optional rigid pipe adaptor(Part#510-994)when using rigid pipe vent systems. Vertical Venting with Three(3)90°Elbows One 90°elbow❑TWo 45°elbows. Option V H+ H1 V+V1 C A) 1' Min. 2' Max 3' Min. With these options, max.total pipe length B) 2' Min. 3' Max 4' Min. is 30 feet with min.of C) 3' Min. 4' Max 6' Min. 10 feet total vertical V1 and max.8 feet total D) 4' Min. 5' Max 7' Min. horizontal. E) 5' Min. 6' Max 8' Min. Please note min. 1 f�O` F) 6' Min. 7' Max 9' Min. foot between 90° �J elbows is required. G) 7' Min. 8' Max 10' Min. H1 O V Lengths do not include elbow indicated Restrictor Set 0-Factory Setting i RECEIVED 07/31/2019 ASPEN BUILDING DEPARTMENT IZEINF ØRIcy CV40E-11 Gas Fireplace TV RECESSED INTO WALL MAXIMUM TV RECESS TV FLUSH WITH HEARTH Max 3" Max 3" To Top of Enclosure To Top of Enclosure 411 I Chasewen2 mining 1 ► I 1120in2min Chase vent opening ri 5/8"Max 4 kl "TV recess with drywall 1 up against unit 1 I F� Max.2 x 4 stud iiI \, i\ Max.2 x 4 stud \ I I I 4I 11 I I ►;lI, 1I �� Header StudCS 1CA CE N Max 5 —V Mantle Screws must not ° penetrate unit more than 1/2". ❑ Adhere to"No Screw" Max 36" ° zones painted on unit. Hearth Glue can be used B v I1 ® 0 v —� as an alternative. _-iNEM li 0_4 ► iI 4 5/8"maximum TV recess using 1/2"drywall Flush wall TV recess using 1/2"drywall CB40E shown CB40E shown RECEIVED 07/31/2019 ASPEN BUILDING DEPARTMENT