HomeMy WebLinkAboutFile Documents.124 W Hyman Ave.0051.2019 (8).ARBK 0051 -2019-arbk_building comments_1
30.Architectural Plans.pdf(7)
A.7.01 SCHEDULES Subject: PlanCheck
Page Label: 1 Show location of unit within
Page Index: 1 building
Author: tonyf for dwelling separation and STD
Show location of unit within building Date: 4/10/2019 9:45:05 AM purposes
for dwelling separation and STD
purposes File Name: 30.Architectural Plans.pdf
SEE ADDED SHEET A.1.01 "SITE PLAN &UNIT BUILDING RELATIONSHIP"TO LOCATION
OF UNIT 2-B WITHIN THE CONTEXT OF THE BUILDING
Subject: PlanCheck
Page Label: 5 Specify if wood burning fireplace
`
Page Index: 5 will remain.A hearth extension is
—, Author: tonyf required for wood burners. Refer
_____=____ Date: 4/4/2019 3:33:47 PM IRC sec R1001.9 and provide
File Name: 30.Architectural Plans.pdf fireplace details.
�s,�aoa.,.a,cea�,, -;-----1 SEE UPDATED SHEET A.2.04 "MAIN LEVEL DEMOLITION PLAN" FOR AMENDED NOTE ABOUT
--;3, °__° FIREPLACE. THE BRICK FIREPLACE IS TO REMAIN,THE EXISTING BENCH IS TO BE REMOVED
Subject: PlanCheck
Page Label: 6 Identify adjacent dwelling units
Page Index: 6 and dwelling separation walls
Author: tonyf
Identify adjacent dwelling units and dwelling Date: 4/3/2019 12:14:54 PM
separation walls File Name: 30.Architectural Plans.pdf
SEE UPDATED SHEET A.2.01 "EXISTING MAIN LEVEL FLOOR PLAN" FOR NOTES DEPICTING
WHICH WALLS ARE TYPICAL EXTERIOR WALLS AND WHICH ARE DWELLING SEPARATION WALLS.
Subject: PlanCheck
Page Label: 9 Provide product cut sheets and
Page Index: 9 STD and fire resistivity rating.
Author: tonyf Identify if this is a dwelling
Provide product cut sheets and Date: 4/10/2019 10:23:48 AM separation
STD and fire resistivity rating.
r Identify if this is a dwelling File Name: 30.Architectural Plans.pdf
r separation
PIC BLY
E:3" = r-o^ CUT SHEETS ARE NOW ATTACHED TO COMMENT RESPONSES. STC RATINGS AND FIRE RATINGS
ARE NOW INCLUDED IN DETAILS (MODELED AFTER GYPSUM ASSOCATION'S FILES)
0
Subject: PlanCheck Detail how dropped ceiling is
.„..„......, 1 Page Label: 9
����� �� aI=. I CEILING TO Page Index: 9 constructed and how it complies
"""
oRO
1 � z Author: tonyf with IBC sec 803.13
--
o Date: 4/10/2019 10:37:48 AM
t 1 F,oXa ME.e,o .E,—oE� w
L File Name: 30.Architectural Plans.pdf
". D IW gM1 d!es' W
1.1 anEM1 plea wM IBC 803.13 o SEE UPDATED DETAIL. DROPPED CEILINGS WILL BE FRAMED WITH NONCOMBUSTIBLE FRAMING
II
WOOD e[m+io urwn DATE)
/ Subject: PlanCheck
w Specs not found, please provide
Specs not found, Page Label: 9
please provide 0 Page Index: 9
ASSUMED OORASSEMBLY Author: tonyf
ce Date: 4/10/2019 10:53:27 AM
EXISTI"GGW CEILING T°REMAIN w File Name: 30.Architectural Plans.pdf
`.)
7
COMMERCIAL A,•: LU S
FLOOR BLOKKE",SEE SPECS Q
N CUT SHEETS ARE NOW ATTACHED TO COMMENT RESPONSES.
DROPPED CEILING BELOW LU
EXISTING GWB CEILING,
Subject: PlanCheck
Page Label: 10 Where are these windows to be
Page Index: 10 used?A.2.04 does not show any
Author: tonyf window replacement
Where are these windows to be used?A.2.04 , Date: 4/10/2019 11:01:14 AM
does not show any window replacement File Name: 30.Architectural Plans.pdf
SEE UPDATED WINDOW SCHEDULE, NOTES WERE ADDED; "EXISTING TO REMAIN, HOA DOES NOT
ALLOW ANY ALTERATIONS TO WINDOWS"
Technical Data -- --- ---- -
-- --- ---- -
COMMERCIAL
Commercial Acoustics Floor BlokkerTM ACOUSTICS
Commercial Acoustics Floor Blokker is a highly engineered sound-damping underlayment
that is designed to be installed underneath any style flooring to create quieter living or
working spaces throughout an entire location. The Floor Blokker provides the
most cost-effective way to meet the Building Code requirement of STC/IIC
50 on a number of wood and concrete assemblies.
For General Contractors, Designers, and Architects,
Delta IIC Commercial Acoustics Floor Blokker is designed to
of 26 effectively dampen both impact and airborne noise
Easily installs underneath the Uses Include:
following flooring types - individual
installation instructions available: ✓ Commercial & Residential
✓ Luxury Vinyl Tile ✓ Multi-family
✓ Hardwood ✓ Hotels
✓ Carpet ✓ Music Studios
✓ Ceramic or Porcelain Tile ✓ Movie Theaters
✓ Gypsum Concrete
✓ Laminate
Commercial Acoustics Floor Blokker is a 3-in-1 barrier for sound, moisture and air. Allowing you
to build quieter structures with less material and labor, while also increasing HVAC efficiency and
mold and mildew prevention. Commercial Acoustics Floor Blokker is a post-industrial recycled product,
and is 100% recyclable at end-of-life.
Flooring Type Assembly(Additional Tests Available)—All Tests Include Floor Blokker
Tile Ceramic tile on 6" concrete slab 51 53
Tile Ceramic on wood joist with 1.5"thick gypsum concrete topping 55 50
Tile Ceramic tile on 6" concrete concrete slab with Ceiling Assembly 58 57
Hardwood 1/2" Engineered hardwood on 6" concrete non-isolated slab 47 53
Hardwood 1/2" Engineered hardwood on wood joist with 1.5" thick gypsum concrete 55 54
Laminate Laminate Flooring on 8" concrete slab with Ceiling Assembly 58 58
LVT LVT on 6" concrete slab with Ceiling Assembly 70 60
LVT LVT on 6" concrete slab 56 50
LVT LVT on 18" Open Web Truss with Ceiling Assembly 53 62
Tested and approved for use in all wall designs of the U300, U400, and V400 series.
�noro� 4�dueP
1519 W. Cypress St. • Tampa,Florida 33606 • 888-815-9691 t1 Z
COMMERCIAL
o u sR i c s L www.Commercial-Acoustics.com • info@commercial-acoustics.comf7tvi ��rluLF�
Product Specifications
EVA= Ethylene Vinyl Acetate = 4Ir ,. ,.
• Made from Post-Industrial Recycled _
Automotive Products y; "
• Non PVC (no ozone depleting gasses)
• Sustainable: 100% Fully recyclable at end of
life
• Mold and mildew resistant
• 3-in-1 barrier (sound, moisture & air)
• Easy to install- Reduces cost (labor & i aIli mull
materials)
• Dampens sound and blocks noise up to 75%
• A cost-effective subfloor application
that's easy to install under any style of
flooring, walls or ceilings. (wood, tile, stone,
carpet, vinyl, gypsum board).
Features / Benefits = - _ '``
• Reduces airborne and impact noise by 75%
• Build quieter structures with less material and labor
• Air and moisture barrier for HVAC efficiency and mold and mildew prevention
Installation
• Black, EVA side up for Glue Down Applications (Laminate, Vinyl, Hardwood)
• White, Scrim side up for hard surface flooring (Ceramic Tile or Floated Floors)
• Detailed Installation Instructions available for each assembly
Tested and approved for use in all wall designs of the U300, U400, and V400 series.
1519 W. Cypress St. • Tampa,Florida 33606 • 888-815-9691 nor`" t¢e
�Z
COMMERCIAL
usRiIALwww•Commercial-Acoustics.com • info@commercial-acoustics.com $ � ®
o f l
Installation Instructions
1. Place Floor Blokker with the black EVA(vinyl) side in accordance with the flooring used:
a. Ceramic Tile: Black EVA side down
b. Floating Floors: Black EVA side down
c. Glue-Down LVT or Glue-Down Hardwood: Black EVA side up
d. Carpet Flooring: Black EVA side up
2. Place edge to edge multiple pieces of Floor Blokker to complete the coverage of the room being
treated.
3. Add desired flooring on top of Floor Blokker as per recommended installation techniques.
a. Carpet layers can go directly on top
b. Wood floors can be nailed directly on top
c. Laminate floors can be floated directly on top
d. Ceramic floors can have the adhesive compound added to the top surface of Floor Blokker then
add the ceramic tile to complete the job.
O
Tested and approved for use in all wall designs of the U300, U400, and V400 series.
1519 W. Cypress St. • Tampa,Florida 33606 • 888-815-9691 nor`" t�Z
COMMERCIAL
u s R i sL � � UL
www•Commercia-Acoustcs.com • no@commercial-acoustcs.com e ®
oc l
Technical Data COMMERCIAL
ACOUSTICS
Wall Blokker PROTM
Acoustical Sound Barrier and Isolator
World's First Soundproofing Membrane designed specifically to increase sound attenuation across walls—
Hit Higher STCs at a fraction of the Cost
Commercial Acoustics Wall Blokker PRO is a specially engineered and
unique sound reduction material that combines a flexible mass loaded
barrier and a soft, fibrous isolation layer to mitigate sound over a wideIlitir ilik
frequency range. Designed to be used anywhere superior noise reduction
is required, Wall Blokker PRO can be installed behind a finished wall
during new construction or can be placed between an existing wall and
an additional drywall layer. The flexibility of Wall Blokker PRO also makes
it extremely effective when used to cover pipe and duct chases to
reduce mechanical noises.
Product Specifications:
• Manufactured with pre & post industrial & consumer materials.
• Mass-Loaded EVA (Ethylene Vinyl Acetate) for STC improvement
• PE (Polyethylene) Scrim for IIC and Structure-Borne improvement
• Product dimensions: 4' by 8' sheet & 4'x25' rolls.
• Product Weight: 1.0 lb/ft2 composite nominal @ 3/16" nominal
thickness.
• Standard Tolerances: Length & Width: + 0.5"/ - 0.0".
Product Benefits:
• Designed specifically to attenuate sound
• Flexible & easy to install
• Thin, approximately 1/8" thick - Saves space over traditional options such as Resilient
Channel & Drywall
• Dampens sound and reduces noise by up to 75%
• 3-in-1 barrier (sound, moisture and air)
• Mold and Mildew resistant
• Non-PVC (no ozone depleting gasses)
• High STC performance in single and multiple layer applications
• Sustainable: 100% fully recyclable at end of life
• 100% Made in the USA
• Made from recycled, highly engineered acoustical grade polymer.
• Polyester manufactured from recycled bottle content.
Tested and approved for use in all wall designs of the U300, U400, and V400 series.
dq
1519 W. Cypress St. • Tampa, Florida 33606 • 888-815-9691 Apo t1 i
COMMERCIAL www.Commercial-Acoustics.com • info@commercial-acoustics.com 4121
ACOUSTICS 4'£u0. ou4—, EREO
Lab Test Performance:
• Flammability rating meets ASTM E 1 19; fire rated
loaded wall assembly.
• Thermal Resistance minimum of 3 per ASTM C 518-
5. `--
• Product-Only Minimum STC 27 per ASTM E 90-02 or
SAE J1400. STC per assembly rating on request. r •
• Lab and Field Tests available on dozens of
configurations, including Wood and Metal Stud Walls, IP
Single or Staggered Stud, and Various Drywall 0
Configurations
• No fungal or algae growth and no visible
disfigurement per ASTM D3273 and ASTM G 21 . ,
Installation:
1 . Ensure surface is clean and dry
2. Wall Blokker PRO attached to wood studs with staples Installation Overview:
or screws, and metal studs with screws
•
3. Roll the Wall Blokker PRO to the proper length of the Installs vertically, directly to studs,
wall, measured vertically beneath the drywall
•
4. Start at the top of the wall, securing the Wall Blokker Scrim (white side)should be facing
PRO to the header stud with 4-5 staples inward (towards the studs)
•
5. Roll the membrane downward, so that each edge is Installation requires two or more
directly in the middle of the adjacent stud capable technicians/hangers
6. Secure the membrane to the studs at 12 inches, • No special training required
nominally
7. Taping of the edges is optional
a. Mandatory if the edge does not fall on the stud
8. Use standard drywall screws when fastening drywall board to the studs through the
membrane. Wall Blokker PRO is an EVA polymer that will tighten around the screws like a
gasket
9. If holes/tears should take place, simply place vinyl tape over the gap
10.At bottom and top of the wall, ensure that gaps are less than or equal to ''/a". Fill in gaps with
non-hardening caulk
11 .For HVAC, plumbing, or electrical penetrations, fill gap with fiberglass batting as needed and
close with caulk
12.For overhead placement, placement on top of drywall prior to installation is recommended
13.Installation should not begin until all other trades are finished in the area
14.It is recommended that areas to receive Wall Blokker PRO be weather tight. Materials can be
stiff and less pliable at low temperatures
Tested and approved for use in all wall designs of the U300, U400, and V400 series.
oaoro 4eduee
1519 W. Cypress St. • Tampa, Florida 33606 • 888-815-9691 1.' UL
COMMERCIAL %' Q�
ACOUSTICS www.Commercial-Acoustics.com • info@commercial-acoustics.com �hf U S�• �4.:,a`� c�srfRE��\