0 Specification Submittal Data
Panasonic Radiation Damper
for Combustible Assemblies
Description: UL listed assembly with Panasonic
ENERGY STAR®models: O ���
Radiation damper shall be assembled with .�
select ENERGY STAR®rated ventilation fans, WhisperGreen®Select": FV 0511 VK2, O ` /3/8"
fan/lights and fans with motion/condensation FV-0511 VKL2,FV-0511 VKS2,FV-0511 VKSL2,
sensors.Damper shall be UL and cUL listed FV-1115VKS2,FV-1115VKSL2,FV-05-11 VK1. 3-9/16" � 13-�1/4"
for wood truss assemblies and meet UL 555C FV-05-11 VKL1,FV-05-11 VKS1, 44 % y
for use in 1 hour fire-rated floor/ceiling or roof/ FV-05-11VKSL1,FV-11-15VK1,FV-11-15VKL1 ��
ceiling asexceed
National
s slisted below. nD nt 11.
G.
shall exceed National Fire Protection Agency WhisperCeiling®/WhisperCeiling®DC'":
NFPA-90A. FV-05VQ5,FV-08VQ5, FV-08VQL5,
11-7/8" 1-7/8"
FV-08VQL6,FV-11 VQ5,FV-11 VQL5,
Features: FV-11VQL6,FV-15VQ5,FV-15VQL5,
•UL 555C listed for use in a 1 hour fire-rated FV-15VQL6,FV-0511 VQ1,FV-1115VQ1,
wood truss floor/ceiling and roof/ceiling FV-0511VQL1,FV-1115VQL1 PC-RDO5C5
designs' WhisperSense®/WhisperSense®DC":
•165 degree Fahrenheit fusible link. FVO8VQC5,FV08VQCL5,FV-08VQCL6,
•High-temperature,non-asbestos,reinforced FV-11VQC5,FV-11VQCL5,FV-11VQCL6,
fiber thermal fabric. FV-0511 VQC1,FV-0511 VQCL1
•Galvanized steel frame. WhisperFit®/WhisperFit®EZ':FV-05VF2,
•Damper sleeve allows for fan/motor access for FV-05VFL4,FV-05VFM2,FV-08-11 VF5,
ongoing maintenance or framing/drywall/paint FV-08-11 VFLS,FV-08-11 VFM5,FV-08VF2,
installation staging. FV-08VFL4,FV-08VFM2,FV-11VF2,FV-11VFL4
O •Drywall support installation after drywall WhisperValue®/WhisperValue®DC"':
to make fan/damper assembly meet UL FV-0510VS1,FV-0810VSS1,FV-0510VSC1,
Combustible Assemblies. FV-0510VSL1,FV-0810VSSL1,FV-0510VSCL1,
FV-05VS1,FV-05VS3,FV-08VS3,FV-08VSL3,
FV-10VS1,FV-10VS3,FV-10VSL3,FV-10VS3E,
*UL 555C classification for the following 1 hour UL Wood FV-10VSL3E Truss Assembly Ratings:L521,L528,L546,L558, 3/8u
L562,L574,L576,L581,L583,L585,M509;P522,
P-533,P-538,P-545 and P-547.
Mil) 3-9/16" 3-1/4" L - --
y• • - .fir
c.
® 6
Warnoek Hersey
7-1
t' - '1 C UL US km
File#:3225-1598:100 File#:WHI-495-PSH-0177,-0178 11-7/8"
For complete Installation Instructions visit us.panasonic.com/ventfans
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
RECEIVEAssembly i See following page
application.for Non-Combustible
O
Panasonic Eco Solutions North America
Eco Products D a 10/21/2019
Two Riverfront Plaza
Newark,NJ 07102
us.panasonic.com/ventfans ASPEN
BUILDING DEPARTMENT Panasonic
VF191136SS_PC-RD05C5 Combust
Flex DamperTM PC-RD05C5
O Specification Submittal Data
Panasonic Radiation Damper
for Non-Combustible Assemblies
Description: UL listed assembly with Panasonic
ENERGY STAR®models:
Radiation damper shall be assembled with O
select ENERGY STAR®rated ventilation fans, WhisperGreen®Select": FV-0511 VK2, riA
fan/lightsand fans with motion/condensation FV-051 1 VKL2,FV-051 1VKS2, FV-051 1 VKSL2, O `, iii �3/8"
sensors.Damper shall be UL and cUL listed for FV-1115VKS2,FV-1115VKSL2,FV-05-11 VK1.
T bar,hanger rod/wire ceiling installation and FV-05 11 VKL1,FV-05 11 VKS1, 3-9/16"
3-1/4"
exceedUL 555C for use in 3-hour fire rated floor/ FV-05-11 VKSL1,FV-11-15VK1,FV-11-15VKL1 4.- - /�‘�
ceiling or roof/ceiling assemblies,Damper shall jilio
exceed National Fire Protection Agency NFPA- WhisperCeiling®/WhisperCeiling®DC'":
90A. FV-05VQ5,FV-08VQ5,FV-08VQL5,FV-08VQL6,FV-11VQ5,FV-11VQL5,FV-11VQL6,FV-15VQ5,
11-7/8" / 11-7/8"
Features: FV-15VQL5,FV-15VQL6,FV-0511 VQ1,
•UL 555C listed for use in a 1,2 or 3 hour fire FV-1115VQ1,FV-0511 VQL1,FV-1115VQL1
rated floor/ceiling and roof/ceiling designs.* WhisperSense®/WhisperSense®DC":
•165 degree Fahrenheit fusible link. FV-08VQC5,FV-08VQCL5,FV-08VQCL6, PC-RDO5C5
•High-temperature,non-asbestos,reinforced FV-11VQC5,FV-11VQCL5,FV-11VQCL6,FV-
fiber thermal fabric. 0511 VQC1,FV-0511 VQCL1
•Galvanized steel frame. WhisperFit®/WhisperFit®EZ':FV-05VF2,
•Damper sleeve allows for fan/motor access for FV-05VFL4,FV-05VFM2,FV-08 11 VF5,
FV-
ongoing maintenance or framing/drywall/paint 08 11 VFL5,FV 08 11 VFM5,FV 08VF2,
nstallation staging. FV-08VFL4,FV-08VFM2,FV-11VF2,FV-11VFL4
O WhisperValue®/WhisperValue®DC":
FV-0510VS1,FV-0810VSS1,FV-0510VSC1,
FV-0510VSL1,FV-0810VSSL1,FV-0510VSCL1,
UL and Warnock Hersey 555C classification for FV-05VS1,FV-05VS3,FV-08VS3,FV-08VSL3,
1,2 or 3 hour Non-Combustible Assemblies. FV-1 OVS1,FV-10VS3,FV-10VSL3,FV-10VS3E,
FV-10VSL3E
3/8"
1
% TI 3-9/16 3-1/4"
Warnock Hersey r
�� y 1 CID - -
p pp W 1 1
File#:3225-1598:100 File it:WHI-495-PSH-0177,-0178 Al 11-7/8"
For complete Installation Instructions visit us.panasonic.com/ventfans
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date: