Loading...
HomeMy WebLinkAboutFile Documents.1419 Crystal Lake Rd.0009.2017 (34).ARBK ♦ • DUC SERIES FC-2,5,6 DUC Nomenclature Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Example DU C 0 6 B A A S 1 A B A M Model Series T M-not used DUC-DIRECT DRIVE Universal Mount DRAIN PAN OPTIONS A- STANDARD-"vertical right Unit Size hand drain connections"only 06- 600 CFM B-- STAINLESS STEEL-"vertical right 08- 800 CFM hand drain connections"only 10-- 1000 CFM C- UNIVERSAL 12-- 1200 CFM D- UNIVERSAL-Stainless Steel 14-- 1400 CFM 16-- 1600 CFM RETURN AIR CABINET OPTIONS 20- 2000 CFM B- BOTTOM RETURN(STD) R- RIGHT RETURN Primary Coil Type&Capacity L-- LEFT RETURN B-- 3 ROW WATER or LOW CAP C-- 4 ROW WATER or HIGH CAP CONTROLS D- 4 ROW DX with biflow TXV(HP ready) R-22 B-- FAN CONTROL 24V(STD)' F-- 4 ROW DX with biflow TXV(HP ready) R-410A D- MULTI-FUNCTION CONTROLLER H-- 4 ROW DX with no metering device R-22IR-410A* E-- MULTI-FUNCTION CONTROLLER 'TXV is shipped separately and field installed. (w/Hot Water Heat-Low Limit) F-- MULTI-FUNCTION CONTROLLER Secondary coil type and capacity (w/Aquastat) (2ND COIL IN AIRFLOW) G-- MULTI-FUNCTION CONTROLLER A- NONE OR 2 PIPE CW/HW/DX(Hot Water Top will be provided) (w/Aquastat&Hot Water Heat-Low Limit) B- Electric Heat Ready(field installed Electric Heat) Notes: 2- 2 ROW HW(06-12 models only) *1. Blower time delay on break provided on 3- 3 ROW HW DX cooling.No time delay provided for 4- 4 ROW HW(14-20 models only) chilled water cooling. C- 3.0 kW-single phase(06-12 models only) D-- 5.0 kW-single phase(06-12 models only) MOTOR VOLTAGE/PHASE E- 6.0 kW-single phase(06-12 models only) 1 -- 120/1/60 F-- 8.0 kW-single phase 2-- 208/240/1/60(customer to change transformer G- 10.0 kW-single phase tap for 208V) H- 15.0 kW-single phase(10-20 models only) Notes: I- 20.0 kW-single phase(14-20 models only) 1. Motor voltage must match electric heat voltage Notes: for single phase electric heat. 1. Electric Heat kW rated at 240V.208V Heaters are derated from 240V. FUTURE USE 2. Electric Heat complete with molded case switch. S- not used 3. 15 and 20 kW shall have two supply circuits. 4. Option"A"is not field convertible to electric heat FUTURE USE A- not used RECEIVED 09/29/2017 010-760002-000 2 DUC 1.0 I/08 ASPEN BUILDING DEPARTMENT 4 • " ® DUC SERIES Physical Data Model DUC 06 08 10 12 14 16 20 Nominal Capacity(tons) 1.5 2 2.5 3 3.5 4 5 Nominal CFM 600 800 1000 1200 1400 1600 2000 Fan Diameter(in) 9 9 11 11 11 11 12 Width(in) 6 6 7 7 9 9 9 Filter Quantity 1 Nominal Size 16x20 16x20 18x24 18x24 20x25 20x25 20x30 Coils Face Area-DX(sqft) 2.01 2.01 3.06 3.06 3.97 3.97 5.24 FPI-DX 14 14 14 14 10 10 _ 10 Face Area-Chilled Water(sqft) 2.01 2.01 3.06 3.06 3.97 3.97 5.24 FPI-Chilled Water - 10 10 - 10 10 Face Area-Hot Water(sqft) - 1.72 - 2.30 - 2.84 3.72 FPI-Hot Water - 12.00 - 12.00 - 12.00 12.00 Coil Connections Chilled Water-Supply-Return 7/8-7/8 7/8-7/8 7/8-7/8 7/8-7/8 7/8-7/8 7/8-7/8 1 1/8-1 1/8 Hot Water-Supply-Return 5/8-5/8 5/8-5/8 5/8-5/8 5/8-5/8 7/8-7/8 7/8-7/8 7/8-7/8 DX-Liquid-Suction 3/8-7/8 3/8-7/8 3/8-7/8 3/8-7/8 3/8-1 1/8 3/8-1 1/8 3/8-1 1/8 Condensate Drain Line Primary 3/4"FPT Secondary 3/4"FPT Approximinate Weight(lb) Cooling Only-Electric Heat 135 135 145 145 158 158 T 190 Cooling and Hydronic Heating 160 160 170 170 183 188 220 Unit Dimensions(in) Height 46.75 46.75 51.75 51.75 55.75 55.75 57.75 Width 17.50 17.50 20.00 20.00 22.00 22.00 24.00 Depth 22.00 22.00 25.00 25.00 27.00 27.00 31.00 REC WED 09/29/2017 DUC 1.0 1/08 3 010-760002-000 ASPEN BUILDING DEPARTMENT • ® DUC SERIES The Premium Quality, High Seer Combination Fan Coil Units forVertical and Horizontal Application with Hydronic or Electric Heat All From one Unit! Horizontal Right Hand o ,, i I p Horizontal Left Hand Magic Aire® DU Series Fan Coils are designed for upscale homes,apartments,and condominiums. Engineered with the distributor and installer in mind, one unit satisfies all demands. RECEIVED Universal Drain pan(opt)required for horizontal and left-hand conversions. 0 / / O 1,7 Information subject to change without notice. 7 7 010-760002-000 4 DUC 1.0 1/08 ASPEN BUILDING DEPARTMENT iii • • ® DUC SERIES DUC Chilled Water Unit Dimensional Information MODEL A B C D E F H K M N DUC06/08 17.5 22.0 46.0 35.75 10.25 15.0 16.5 4.63 18.25 14.31 DUC10/12 20.0 25.0 51.0 40.75 10.25 17.0 19.5 4.63 22.25 16.31 DUC14/16 22.0 27.0 55.0 43.75 11.25 19.0 21.5 4.63 23.25 18.31 DUC20 24.0 31-0 57.0 45.75 11.25 21.0 25.5 4.63 28.25 18.31 TOP VIEW (Hot Water NOTES: Heat Unit) (I)Return air openings-Side return air openings require field modification. I STANDARD CABINET (Cooling ______I & Heating) RETURN . , o SUPPLY TYP -- B --E.I 1- A 1,1 H K �C F -�TYP TV? I 3/4" I CENTERED i it l EL I I CIRCUIT BREAKER (ELEC HEAT UNITS ONLY) KNOCKOUT i A O FOR 0 ► ELECTRICAL BLOWER/MOTOR CONNECTIONS ACCESS PANEL (BOTH SIDES) 111 C OPTIONAL RIGHT OR LEFT SIDE RETURN(FIELD MODIFICATION W/SIDE RETURN -SUPPLY FILTER KIT) I D r,_____ ______ 1 ____..z. (1 j -RETURN � O• N l <�=TYP PRIMARY& ---SECONDARY '- I DRAIN CONN. • L-1'/8rcn I II- 1'/8 l Ml7) TYP i (1) TVP LM } -.I- iv ---� TYP TIP CENTERED LEFT VIEW FRONT VIEW RECEIVED Universal Drain pan(opt)required for horizontal and left-hand conversions. Q 9/2 9/2(]17 DUC 1.0 1/08 5 010-760002-000 ASPEN BUILDING DEPARTMENT Airflow Data— DX Units Model Coil Config Fan ESP Speed 0.1 0.2 0.3 0.4 0.5 HIGH 899 832 743 635 543 DX MED* 867 774 712 619 517 DUC-06/08 LOW** 837 761 678 599 505 HIGH* 809 736 665 581 488 DX/Hot Water MED 768 706 631 564 471 LOW** 752 691 615 546 458 HIGH 1273 1167 1042 925 811 DX MED* 1229 1121 1002 871 711 DUC-10/12 LOW** 1108 1041 944 823 677 HIGH 1294 1243 1175 1085 1043 DX/Hot Water MED* 1094 1043 1004 970 920 LOW** 956 934 897 851 811 HIGH 1571 1458 1314 1157 912 DX MED* 1446 1327 1192 1022 866 DUC-14/16 LOW** 1371 1300 1167 974 802 HIGH* 1808 1720 1637 1539 1446 DX/Hot Water MED** 1570 1539 1462 1400 1296 LOW 1353 1339 1271 1232 1192 HIGH* 2234 2109 1966 1823 1656 DX MED** 1753 1705 1649 1552 1419 DUC-20 LOW 1511 1483 1433 1367 1304 HIGH* 2205 2176 2091 2007 1959 DX/Hot Water MED** 1887 1870 1853 1806 1764 LOW 1606 1599 1592 1579 1558 Airflow Data— Chilled Water Units Model Coil Fan ESP Config Speed 0.1 0.2 0.3 0.4 0.5 Chilled HIGH 992 917 855 778 681 Water MED 957 891 824 747 654 DUC-08 LOW 929 864 801 726 646 Chilled HIGH 925 861 804 _ 733 645 Water/Hot MED 894 836 781 707 629 Water LOW 876 824 764 689 612 Chilled HIGH 1372 1293 1195 1083 945 Water MED 1293 1209 1114 1010 875 DUC-12 LOW 1233 1160 1066 957 834 Chilled HIGH 1424 1375 1324 1267 1207 Water/Hot MED 1212 1183 1154 1098 1056 Water LOW 1072 1051 1029 1000 954 Chilled HIGH 1658 1539 1404 1278 1121 FC-2 Water MED 1504 1401 1289 1166 1001 DUC-16 LOW 1376 1284 1201 1079 898 Chilled HIGH 1880 1811 1740 1666 1595 FC 5 6 Water/Hot MED 1794 1728 1666 1595 1513 Water LOW 1659 1608 1548 1485 1420 Chilled HIGH 2145 2013 1878 1732 1593 Water MED 1726 1645 1567 1463 1343 _ DUC-20 LOW 1463 1434 1381 1287 1185 Chilled HIGH 2240 2188 2129 2063 1996 Water/Hot MED 1964 1926 1893 1859 1807 Water LOW 1730 1711 1686 1655 1603 Notes: 1. Data based on dry coil RECEIVED 2. *Factory setting for whole tonage units. 3. **Factory setting for partial tonage units. 0 9/2 9/2 017 DUC I.0 1/08 7 010-7600002-000 ASPEN BUILDING DEPARTMENT • • DUC SERIES MULTI-FUNCTION CONTROLLER Description DUC series multi-position air handlers are available with a Multi-Function Controller that reduces the number of electrical connections and field supplied parts required to install these units with boilers,pumps and condensing units. Heating: Air handlers can now be directly wired from the boiler to the air handler without adding additional relays or related controls. Multiple air handlers may be connected to a single,high-efficiency natural gas or oil fired hot water boiler to provide complete,whole house hydronic space heating.Each air handler includes a high-efficiency cooling coil,a separate hot water coil,drain pan,1 15,208,230 volt three speed blower motor,throwaway filter and a 24V transformer. Cooling: These air handlers are completely compatible with all split system type condensing units.Cooling coils in the DUX-HW air handlers are extra-large and engineered to offer cooling efficiencies to 13 SEER, depending on the condensing unit used. Features Include: • Diagnostic Indicator Lights • 100% Factory Tested • Automatic Multi-Speed Switching • Prevents False Calls for Fan Operation • Simplified Wiring • Universal Thermostat Compatibility • Contractor Friendly PC Board Layout • Increased Operating Efficiency • Available in 115,208,230 volts • Made in USA DX Cooling/ Boiler Heating Heating Cycle I. Boiler Start Relay:Eliminates field installed boiler relay,allowing direct wiring from the boiler to the air handler. 2. Heating Cycle Blower Delay:User selectable 1,3,or 4 minutes delay of the blower start to allow the coil to be preheated before the blower energizes. Cooling Cycle I. Cooling Cycle Blower Delay:Maximizes cooling efficiency by allowing the blower to run I to 100 seconds after the thermostat is satisfied. 2. Horizontal Drain Pan:Factory installed.(re-positions within cabinet for right-to-left airflow) 3. Drain Connections:Primary and secondary on cooling coil. Optional Features I. Freeze Protector:(Optional freeze protector switch required) Reduces the possibility of the water coil freezing by switching the pump on if the water temperature is nearing a freezing condition. 2. Aquastat:An optional aquastat is an available feature that ensures that there is hot water available prior to fan start up. Additional Standard Features I. The diagnostic lights show full functionality of the Fan Control.The green light should always be on indicating that power is connected. Red lights indicate fan operation for heating and cooling modes. 2. Pump dry contact activated for 2 minutes every 24 hours(boiler contacts not activated).User selectable. 3. Pump dry contacts activated for 30 seconds every two weeks (boiler contacts not activated).User selectable. 4. Compatible with most major brands of split condensing units. RECEIVED 09/29/2017 DUC 1.0 1/08 27 010-760002-000 ASPEN BUILDING DEPARTMENT • • 41 r Producing Quality Heating S. Cooling Equipment For Over 50 }ears FC1 FC-3 HB SERIES BELT DRIVE HORIZONTAL CHILLED WATER & DIRECT EXPANSION BLOWER COIL UNITS i _ ,. 1 j ,eittj4* Nominal Sizes I through 20 Ton MAGIC AIRE HB SERIES FAN COILS ARE ETL NTr LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. c , V us United Electric WANED 501 Galveston St.•Wichita Falls,TX 76301 • 940-397-2100 • Fax:940-397-2166•www.magicaire.com 09/29/2017 5-I 2013 HS .4 ASPEN BUILDING DEPARTMENT 44 2.4 9 01.0 A rite, HB Series MODEL NOMENCLATURE HB Series Model Number Nomenclature Belt Drive Horizontal Chilled Water & Direct Expansion Blower Coil Units Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Example HBB30ACAAH2 RH69 L6BDBABM Drain Pan Polymer or Stainless Steel IAQ Horizontal Belt Drive Use our New Magic 4 Selection Software for: Motor Starter • exact unit model selection — Junction Box only or Motor Start/Stop Station • performance data (MSS) Generation • submittal information Insulation (visit www.magicaire.com) IAQ Fiberglass Closed Cell Unit Size Double-Wall 2 through 20 Tons Filters&Face-and-Bypass (800 through 8000 CFM) Dampers MERV 3 and MERV 7 Filters or Face-and-Bypass Damper/ Filter Option Primary Coil&TXV 4 or 6-Row CHW/2-Pipe or Std Cap DX or High Cap DX Motor&Voltage (single or dual circuit) Numerous motor selections including Single Phase standard duty and NEMA Premium 3-phase inverter-ready,with optional Motor Start/Stop Station(MSS). Coil Treatment Phenolic Coating Drive Package Secondary Coil Factory sized belt and pulley selections for ready-to-go fan operation. Driven by 1,2,4 or 6-Row HW or Steam or customers airflow requirement. Electric Heat, factory mounted. Power Supply Coil Arrangement 115V/1 ph/60Hz 208-230/1ph/60Hz 277V/1/3ph/6 Hz Multiple arrangements available:Right 208 230V/3ph/60Hz Hand,Left Hand,Preheat and Reheat 460V/3ph/60Hz RECEIVED 575V/3ph/60Hz 09/29/2017 5-1-2013 Page 5 HB 1.4 ASPEN BUILDING DEPARTMENT 4 . • HB Series c PHYSICAL DATA Physical Data Model HB 4 6 8 12 16 20 30 40 60 80 Capacity/CFM Nominal Capacity(Tons) 1 1.5 2 3 4 5 7.5 10 15 20 NominalCapacity(BTUMR) 12000 18000 24000 36000 48000 60000 90000 120000 180000 240000 Nominal Capacity 400 600 800 1200 1600 2000 3000 4000 6000 8000 Fan Fan Size 90-6T 90-6T 90-6R 90-6R 120-6R 120-9R 150-9R 150-9R 150-12R TW 150-12R TW Filter Pleated l/12x24 2/12x24 2/16x20 Non-Face and (MERV 7) 1/16x32 1/16x32 4/20x20 2/16x25 Bypass Throwaway 1/16x32 1/16x32 2/20x20 2/20x20 2/20x32 2/20x32 2/20x25 2/20x20 2/12x25 3/12x25 Quantity/Nom. (MERV 3) 2/20x25 size(in) Pleated 6/9.8x36.3 6/9.8x36.3 Face and (MERV 7) 1/20x25 1/20x25 (exact) (exact) 4/16x32 Bypass Throwaway n/a Na 1/20x24 1/20x24 1/22.5x25 1/22.5x25 1/30x36 1/30x36 6/20x25 4/16x20 (MERV 3) 1/24x36 1/24x36 Coil Face Area 1-Row 1.58 1.79 1.50 2.39 4.03 5.00 - - - - Face Area-Hydronic 2-Row 1.58 1.79 1.56 2.39 3.52 4.38 6.72 8.86 13.37 17.71 (sq fL) 4-Row 1.58 1.79 2.00 3.06 4.03 5.00 7.47 9.58 13.37 17.71 6-Row 1.58 1.79 2.00 3.06 3.94 5.00 7.47 9.58 13.37 17.71 Face Area-DX(sq ft) 1.19 1.79 2.00 3.06 4.03 5.00 7.17 10.22 13.75 16.67 Coil Rows/FPl Chilled Water/2-Pipe-4 row 4/10 4/10 4/10 4/10 4/10 4/10 4/10 4/10 4/10 4/10 Chilled Water/2-Pipe-6 row 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 Std Capacity Steam 2/8 2/8 2/6 2/6 2/6 2/6 2/6 2/6 2/6 2/6 High Capacity Steam (See mote tl p Y 2/14 2/14 2/14 2/14 2/14 2/14 2/14 2/14 Std Capacity DX 3/10 3/10 3/12 3/10 3/12 3/12 3/12 4/12 4/10 4/10 High Capacity DX 6/10 6/10 6/12 6/10 6/10 6/10 6/10 6/10 6/12 6/10 Max Coil Rows 10 Rows Total(notes 1,2) CodConnections(in) Chilled Water 14-Row 0.75 0.75 0.75 0.875 1.125 . 1.625 (OD Copper Tube) 375 6 0.875 1.125 1.375 11.375 1.625 1.625 Hot Water(OD Copper Tube) 0.75 0.625 0.625 0.625 0.875 0.875 1.125 1.125 1.125 1.125 Steam-Std Cap-Supply/Return(MPT) 1.50/1.00 1.50/1.00 1.50/1.00 1.50/1.00 1.50/1.00 1.50/1.00 1.50/1.00 2.50/1.25 2.00/1.50 2.00/1.50 Steam-High Cap-Supply/Return(MPT) - - 1.50/1.00 1.50/1.00 1.50/1.00 1.50/1.00 1.50/1.00 2.00/1.25 2.50/1.50 2.50/1.50 Std Cap DX Liquid(OD Sweat) 0.375 0.375 0.375 0.375 0.375 0.625 0.5 0.5 - - Suction(OD Sweat) 0.625 0.625 0.75 0.75 0.75 1.125 0.875 1.125 - - Std Cap DX Liquid(OD Sweat)2ea - - 0.375 0.375 0.375 0.375 0.5 0.5 0.625 0.625 (dual ckt) Suction(OD Sweat)2ea - - 0.75 0.75 0.75 0.75 0.875 1.125 1.125 1.375 High Cap DX Liquid(OD Sweat) 0.375 0.375 0.375 0.5 0.625 0.625 0.5 1.125 - - Suction(OD Sweat) 0.75 0.75 0.75 0.875 0.875 1.125 0.875 1.375 - - High Cap DX Liquid(OD Sweat)2ea - - 0.375 0.375 0.5 0.5 0.5 0.5 0.625 0.625 (dual ckt) Suction(OD Sweat)2ea - - 0.75 0.75 0.875 0.875 1.125 1.125 1.375 1.375 Condensate Drain Line Primary 3/4"FPT Coil Volume Hot Water-1 row(gal) 0.1 0.2 0.2 0.3 0.5 0.6 - - - - Hot Water-2 row(gal) 0.3 0.3 0.3 0.7 0.7 0.9 1.3 1.7 2.6 3.5 Chilled Water/2-Pipe-4 row(gal) 0.5 0.6 0.6 0.8 1.1 1.4 2.9 3.8 5.3 6.9 Chilled Water/2-Pipe-6 row(gal) 0.8 0.9 0.8 1.3 1.7 2.1 4.4 5.6 7.9 10.4 Std Capacity DX 68 103 115 175 231 286 410 780 1050 1272 High Capacity DX (Cu in)(note 3) 136 205 229 350 461 573 821 1171 1575 1909 Notes: 1. Steam coils are 1-row,5/8"tube-in-tube steam distributing type construction. When calcuating total rows of coil for the unit,these count as 2 rows RECEIVED 2. Additional 14 rows are possible using Magic Aire"Auxiliary Cal Section"factory-assembled,field-installed coil module accessory. See www.magicaire.com for deta 3. For dual circuit coils,volume is half of that listed,per circuit 09/29/2017 5-1-2013 Page 6 HB 1.4 ASPEN BUILDING DEPARTMENT 4 • • ,c, H B04-80 RIGHT HAND CONNECTION .. B 0.875(OPP SIDE) Motor Start/Stop station Power Conn. (optional) 0.875 Power Conn. J-BOX H 1,H2 WO_+I (w/o MSS) 0 0 -t-it ••• .•_1_ ' ' ter, III • 12.51 11 G 10 Cl, c2 J OR 0.875 24V C3 Control Conn. F - E O( I 1 • . 010IMEll 8.12 a 3/4 FPT Drain conn. FRONT VIEW(SIZES 04-40) iHt.H2 N 0.875 KO(TYP) (TYP) I (TOP/BTM) 1- r-- I1 G M(TYP) II I II� I1 (TYP) 1 E +- F h F-.-1 E TOP VIEW FRONT VIEW(SIZES 60, 80) (TWIN BLOWER;MSS&J-BOX NOT SHOWN) D r A D .r K "1. .L O X L FILTER .1 • . . ... e - O •n.r :� 6.35111- LEFT SIDE VIEW REAR VIEW UNIT CABINET DIMENSIONS UNIT OUTLINE UNIT MOUNTING BLOWER OPENING RETURN 7 MODEL OUTLET CONNECTION A B C12 C22 C32 D E H13 H22 M N P F G K L H131304/06 38.00 28.00 14.10 15.10 N/A 1.00 9.60 1.00 N/A 1.60 2.60 3.30 8.60 10.60 22.00 12.30 HB808/12 37.10 36.60 18.10 19.00 24.89 1.00 14.10 1.00 8.15 1.50 150 2.90 8.40 10.60 27.60 16.40 H8B16 42.00 45.00 22.10 23.00 29.25 1.00 17.90 1.00 7.84 1.50 1.50 2.70 9.10 13.80 36.00 20.00 FC-1,3 HBB20 42.00 45.00 22.10 23.00 29.25 1.00 14.30 1.00 7.84 1.50 150 2.70 12.50 13.80 36.00 20.00 HBB30/40 52.50 57.00 34.80 34.80 40.44 1.00 21.80 9.10 15.02 2.80 2.80 2.80 13.40 16.20 48.00 32.20 HBB60 57.50 67.20 43.00 43.00 53.66 N/A 11.41 8.00 30.11 3.70 3.70 3.70 (2)16.41 (2)16.41 57.90 40.50 HBB80 57.50 7230 48.00 48.00 56.11 N/A 14.01 13.00 28.01 3.70 3.70 3.70 (2)16.41 (2)16.41 66.00 45.70 NOTES: 1.HBB60 and HBB80 aretwin blowers.Dimension"E"is to closest blower.Dimension"F"and"G"are typical for both fan outlets. 2."Cl"dimension is for standard unit(Non-Face&Bypass)."C2"dimension is for double wall units(Non-Face&Bypass).C3 dimension is for single wall Face&Bypass units 4.Unit handis determined ifor bFa looking into theuni filters in same odirection n s airflow.allRight hand unit shown for reference. 4.Hl dimension is for non-Face Bypass& units.H2 dimension is for single wall Face&Bypass units. 5.Electrical connections are on same side as cooling coi I(or single coil)connections. -RECEIVE U 6.Not to scale. -.. 7.Three dimensions are for non-Face&Bypass units.See"HB FACE AND BYPASS"for return connections for units with Face&Bypass. 0 9/2 9/2 017 5-1-2013 Page 7 HB 1.4 ASPEN BUILDING DEPARTMENT iii • • ,,1, H B04-80 SERVICE CLEARANCES TOP q/RF4 Oil, FRONT lii ., IjI. i CONTROLS SERVICE CLEARANCE (E 24 + (ON EITHER SIDE) r FILTER SERVICE 1 CLEARANCE RIGHT i FILTER ACCESS MIXING BOX ACCESSOR (ONLY ONE SIDE IS REQUIRED) SIDE SERVICE CLEARANCE (OPTIONAL) D 1 ISO VIEW i (ON EITHER SIDE C COIL CONNECTION COIL(S) COIL CONNECTION AREA (NOTE 3) AREA (NOTE 3) i i ;--* B MOTOR BLOWER/MOTOR/ BLOWER/MOTOR A J-BOX SERVICE SERVICE A CLEARANCE FAN CLEARANCE (NOTE 2) (NOTE 2) • - w•. J-BOX W 1 MOTOR START/STOP F.. a r r Li I STATION (MSS) 41.0 i". 3.0 MSS SERVICE ` �J (IF PROVIDED) FILTER ACCESS 11.0 PANEL TOP VIEW /ACCESS PANEL �. o 0MILOo a 0 0 COIL i i O PANEL CONDENSATE DRAIN NOTES: PIPING AREA (NOTE 6) I• NOT TO SCALE. REFER TO CATALOG DRAWINGS FOR UNIT OUTLINE DIMENSIONS. 2. MOTOR&BLOWER PULLIES&BELT ARE LOCATED ON THE SAME RIGHT SIDE VIEW SIDE AS COOLING COIL CONNECTION(UNIT WITH 2 COILS) OR 2-PIPE/HEATING COIL CONNECTION (UNIT WITH SINGLE COIL). (MSS NOT SHOWN) 3. ALLOW CLEARANCE FOR FIELD PIPING AS REQUIRED BY THE DIMENSIONS PROJECT REQUIREMENTS. HB UNIT CONNECTIONS MAY BE ON ONE SIDE OR ON BOTH SIDES. SIZE A B C D E 4. REFER TO INSTALLATION INSTRUCTIONS FOR UNIT HANGING (SUSPENSION) REQUIREMENTS. 04,06 18 36 4 30 26 S. COIL,DRAINPAN OR BLOWER REPLACEMENT REQUIRES UNIT TO 08,12 20 I 36 4 36 31 BE REMOVED TO FLOOR FOR SAFE WORKING CONDITION.ALLOW FULL WIDTH OF UNIT FOR COIL REMOVAL.REFER TO SERVICE 16,20 23 36 4 30 38 INSTRUCTIONS. 30,40 30 36 4 36 _ 34 6. ALLOW ADEQUATE DEPTH FOR CONDENSATE ItC IVED 60 31 I 48 4 36 35 REFER TO INSTALLATION INSTRUCTIONS FOR TRAP UE� .� 80 31 j 48 4 36 30 09/29/2017 5-i-zoi3 Page 10 HB 1.4 ASPEN BUILDING DEPARTMENT 4 . • c MIXING BOX ACCESSORY FC3 B F AIRFLOW--- I� 11; � , �s c. a E C . . o. .r. • i, _i___ • ..,,, .7--,.... .,.. . 1 -- p .1 _f E 1 REAR VIEW RIGHT VIEW HBB UNIT Width Heigth Duct Duct Top Approx. Size Length Shipping Filters A(centered) (centered) Width Heigth Clearence Weight ..";Cfil 0 A B C D E F (Ibs) Sze Qty o 0 04/06 22.1 22.1 12.3 20.4 7.6 2.0 40 14 x 20 x 2 2 i '� 08/12 27.0 27.7 16.4 25.9 11.6 2.0 90 16 x 25 x 2 2 I 1 11 • 16/20 27.0 36.2 20.4 34.3 15.0 2.0 140 16 x 32 x 2 2 I 30/40 32.0 48.2 32.4 46.3 15.0 9.7 200 20 x 24 x 2 4 60 36.0 58.0 40.3 56.0 16.0 13.2 260 20 x 25 x 2 4 D II .. 16x25x2 2 • 80 40.0 66.2 45.0 64.3 16.0 15.5 , 320 30 x 20 x 2 6 I II it l il., HBB Unit shown for reference. II II 1 For clarity,not all components are shown. 3.2 J TYP. BOTTOM VIEW AIRFLOW - B i--- F _ E- 00000 a I • .cc. I.---- el E l ` o0000 D -1 REAR VIEW RIGHT VIEW HBB UNIT A Ao 0 Width Heigth Duct Duct Top Approx. 1 IIi Size Length Shipping Filters (centered) (centered) Width Heigth Clearence Weight I. 7 A B C D E F (Ibs) Size Qty 1 04/06 22.1 22.1 12.3 20.4 7.6 4.8 40 14 x 20 x 2 2 D J 08/12 27.0 27.7 16.4 25.9 11.6 4.9 90 16x 25x 2 2 11'I 16/20 27.0 36.2 20.4 34.3 15.0 5.5 140 16 x 32 x 2 2 30/40 32.0 48.2 32.4 46.3 15.0 9.7 200 20 x 24 x 2 4 60 36.0 58.0 40.3 56.0 16.0 13.2 260 20 x 25 x 2 4 ,:I ij a:, 16x25x2 2- 111 1 o�E'� E��E� 80 40 0 66.2 45.0 64.3 16.0 15.5 320 30 x 20 x 2 6 ' 3.2 J TOP VIEW TYP. 09/29/2017 s_1.2013 Page 13 HB 1.4 ASPEN BUILDING DEPARTMENT • • 4 FILTER BOX ACCESSORY /' FC3 0 { 01 ; ''N'::N,,.N.NN,s.s,,,,,....,,..,.,,,7,, MIXING ACCESSORBOXY I ' t...,• • FILTER BOX / ACCESSORY / a D I I-1- C 1 . • . 1 AIR FLOW k" F _ .�,__ - --- f 1 Ia • E I I • • • A 1 I _ --- ,. -_c 9.- 4"MERV 13 I+ B i'd 2"MERV 8 *PER FILTER TYPE UNIT UNIT UNIT FLANGE DUCT DUCT UNIT FILTERS HEIGHT LENGTH DEPTH LENGTH WIDTH HEIGHT WEIGHT PART NUMBER DESCRIPTION A B C D E F (LBS) QTY* NOM NOM EA WIDTH LENGTH 373-600160-001 FB-08-12 HB-BM CABINET 18.2 30.4 12.3 2.0 27.9 16.6 47 1 16 25 373-600161-001 FB-16-20 HB CABINET 22.2 41.2 12.3 2.0 36.4 20.6 57 2 20 20 373-600169-001 FB-16-20 BM CABINET 27.2 , 41.2 12.3 2.0 36.4 25.7 62 2 20 24 373-600170-001 FB-30-40 BM-HB CABINET 34.0 51.2 13-1 2-0 48.4 32.6 98 4 16 25 373-600162-001 FB-60 HB CABINET 42.0 60.7 13.1 2.0 58.1 40.5 121 6 20 RE„,,,„,,A ® n 373-600159-001 FB-60-80-BM 80-HB CABINET 47 I 72.7 13.1 2 66.5 45.8 145 I 3 20 69/29/2017 5-1-2013 Page 14 HB 1.4 ASPEN BUILDING DEPARTMENT „.j I I 4 al„.„....„4 ,... SPRING KIT 1.1 ISOLATOR I SPRING RATED MAX. COLOR A NUMBER RATE LOAD DEFL. SHB-2 25 35 1.4 WHITE I SHB-5 50 74 1.4 YELLOW SHB-10 100 142 1.4 BROWN SHB-20 ! 200 220 1.1 BLACK 5 1/2 1 3 1— 1 SHB-30 1 300 324 1.1 BLUE l i ' F^ SHB-40 420 420 1.0 RED 1 _ 1 I ISHB-50 500 540 1.1 ORANGE i 3 0 NOTES: 1. STEEL RANGER BOX- STANDARD ENAMEL FINISH SPRINGS- STANDARD MODIFIED URETHANE ENAMEL FINISH 2. BOLTS, RODS, NUTS & WASHERS ARE NOT FURNISHED I� WITH HANGER ASSEMBLY ISOLATION 1.� WASHER HBB Spring Vibration Isolators HB Series -0411:10-- HBB Unit Only (No Mixing Box) Unit Part number Unit Mounting Only _ IDP- FRONT REAR f011” HBB04 010-230020-000 YELLOW BROWN HBB06 010-230020-000 YELLOW BROWN L l . 1 1 HBB08 010-230020-000 YELLOW BROWN - - HBB12 010-230019-000 YELLOW BLACK HBB16 010-230019-000 YELLOW BLACK HBB20 010-230019-000 YELLOW BLACK HBB30 010-230021-000 BROWN BLUE HBB40 010-230021-000 BROWN BLUE HBB60 010-230022-000 BLACK ORANGE HBB80 010-230022-000 BLACK ORANGE NOTES: 1. Colors shown for Dynasonics Isolator HBB Unit With Mixing Box(See note 3) Model SHB (RECOMMENDED FOR SIZE 30 AND ABOVE) 2. Springs selected are for a total of 8 rows of coil and ODP motors. Part number FRONT HBB REAR HBB REAR MB 3. For HBB30 and larger with mixing box: HBB30 010-230023-000 BROWN BLACK BROWN 6 each isolators.2 each at front of HB unit, 2 ea at rear of HB unit, 2 ea at rear of HBB40 010-230023-000 BROWN BLACK BROWN mixing box ��� r) HBB60 010-230024-000 BLACK RED BLACK 4. Bolts, Rods, nuts and was HBB80 010-230025-000 BLACK ORANGE BLACK furnished with the hangar assembly 09/29/2017 5-I-20I3 Page 16 HB 14 ASPEN BUILDING DEPARTMENT • • HB04-60 4 o HORIZONTAL AIR HANDLER COIL CONNECTION SUCTION(PT(CKT#2) RETURN OR LIQUID OW(CKT#2) L 1 / UNUSED' ' M L /UNUSED N ,- • • •I I LIQU)O OW{CKT#2) I L.,.Ce SUCTION OT(CKT#2) RETURN�R pK F- SUTION(DT(CKT#I) K • i SUCTION WT(CKT#1) JQ 7_ SUPPLY(DV 01 LI UID OW(CKT#1) (/ H _ J LIQUID ow(CKT#1) r — J • SUI PLY cOV �_ , ; H I� . • CONDENSATE DRAIN G -- CONDENSATE DRAIN , (, F _ �� 0-1 r . Cam' 0 B1.� .41= 0 A B E C D 0 A B E C D DX-SINGLE OR DUAL CIRCUIT AND HYDRONIC COILS DX-SINGLE OR DUAL CIRCUIT AND HYDRONIC COILS (PREHEAT) (REHEAT) VENT OP UNUSED ,/UNUSED RETURN OR J �s M I P� IOW I L STEAM SUPPLY(DX VENT�P K REUrURN OR K "� 1 STEAM SUPPLY(DX J I0 i- IY CONDENSATERETURN(DSJ �� • SUPPLY ItV HPLY(PV NCONDENSATE RETURN�` GN1?ENSATE DRAIN rr y H •INN • • CONDENSATE DRAIN F I \ . Fk l�I* 0 A E B C 0 A B E C STEAM COIL AND HYDRONIC COIL STEAM COIL AND HYDRONIC COIL (PREHEAT) (REHEAT) GAP SUCTION(PT(CKT#2) /VENT SUCTION ItT(CKT#2) ie'"LIQUID(DV(CKT#2) N -I 1 N �� --M 'lI� L --LIQUID V(CKT#2) L VENT�B' / 1 STEAty(SUPPLY OR i STEApd SUPPLY ItR r ce CO DENSATE RETURN mS K K W M W I SUCTION(PT(CKT#1) J J j SUCTION�T(CKT#1) J i LIQUID(DV(CKT#I) r— H LIQUID IV(CKT#T) T-- H I CONDENSATE RETURN OS ; G I CONDNSATE DRAIN i G CONDENSATE DRAIN F ., F ----__--- 0-- r- �— 0— r 0 A E B C 0 A B E C STEAM AND DX-SINGLE OR DUAL CIRCUIT COILS STEAM AND DX-SINGLE OR DUAL CIRCUIT COILS (PREHEAT) (REHEAT) UNUSED simmilimmemmmmagrommaramorma, ommimmor• . I UNUSED' I i I RFr1URN OR NOTES: tY RETURN(DS 1. NOT TO SCALE.Refer to unit dimensional drawings for cabinet dimensions. 1 �■ • • 2. Airflow is from left to right. S1(PPLY(DV 3. Units with right hand connections are shown.Mirror for left hand connection. NOTE:What constitutes"hand"varies among manufacturers. SUPPLY PT Please verify using facility design drawings.Magic Aire defines hand as that side when facing the fitter,draw-through design,air stream hitting G Rat!__• • CONE/TSAI!DRAIN back of head. 4. Size 80 hydronic coils have 2 slabs and therefore have 2 circuits.Apply using * i. _ half of design water flow(GPM)to each circuit. 0F ���. �j— S. For a tr.(single-coile unit,use the sketch unit showing thered coil in RfiE I V E D the fil first coil is attached to unit near filter.The i attached to the first coil). 0 A B E C D 6. Steam coils have MPT supply and condensate return,and �� TWO HYDRONIC COILS connections. (PREHEAT OR REHEAT) 0 9/2 9/2 0 1 7 5-1-2013 Page I7 HB 1.4 ASPEN BUILDING DEPARTMENT W u) O) CD v- N .- LID O O) v- N < LL ,- v— v— v— v- �- O O < <- O 0 '- U) Z d Z Q LL W CII0 c' Z M CD CD CO N ti n OD CA c0 CO CO 1- N N- OD 0 "W O O O O N ,- 0 0 0 0 c5 N O ,- ,- ,- ,- (116 Z w ` u7 0) 0) .--- CO CA 6) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 F- LL O O O O O O O O O O O O O O o CO Z d - C O O O d u) u) CI) u) 1-0 C0 C0 CI] C0 QD Cn C0 C0 CD LI) O O O O O O O O O O O O O O O ® Z Q LL 4 ® Z O M CO. CO CD rI.--1 t` Cb CD CO CD cD I� h- ,- CD CO U W .- O CS CS CSv- N v- CDO CSCj 0 .- N > C D a) .- CD CD CD O O co W ,- CD CT 67 CD C) J O CA O 4 O OMO O C0 C0 O N O W N co co � Q W Z 0 0 0 in o o o o F- u7 C0 M CO 1- N C) C0 CD N- CO N- CO N N (I) LV CR C) CO. I� I� CO .- T CO CO C0 O O O O O .- co QD CO CI) 1-. C' CO f� ,t V C CO W CO 1-. Tr C) v2 CS 6 ,- N N M N N N M M Ni ® d N- C0 U) CO 6) CO a M CQ u) 0 CO CD CD V MN CL X N CD C0 u) C O t` M C0 6 C0 C0 a' 0 n Q 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 x CD CD CD CD 0if) LID LID Ul 0 CD O CD CD CD CD CD 0 CD LID LO LO CD CD CD 0 CD CD r CD CD v- N N N (V N CV Z J C v- D C D N- O) O) 00 .- Imo- N N OO CD N- J J 0) O (..> M .- 4 N N 4 M .66 M M C 6 Cn Cn CL O 0_U U O C- M — O M O C0 �'• CY) CD I� O M CD CD Z p Y r m ,_ ,_ ,_ N N 1- O CD ,_ ,_ ,_ N N U 0 0 0 C0 C0 u7 C0 O O CD O C0 0 u7 C0 Z U CD CD M N 1� t• N u) CD t• M 1- Ch N N O Q i W L. f� r., .- v- 00 0, CO 1- ti CD r- 0, CD CD CD C.) W V) 0 0 r- r- .- r- 0 0 0 Ui N IMMO M CO CD CO N— C' (D N V C Nt CO N CD N- ✓ ZCC U .- 0 0 v- v- N N M N N N M M 4 C' LAD N O r CD .- C0 tb N CD O• ti• CO H Ce Y r< rn d' N r` 6i rn I N CO WW N N Z 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O O CD 0 0 0 0 0 0 0 C0 O O u) c'J M O O N C0 Cp M V C C CD M an O O O O N C0 C0 O O O O O N u) Ct) Z CO C6 6 d 0 m 0 0 0 6 CT 6 6 0 O O Z ® 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ZZC(Dn D o o 0 0 0 0 0 0 0 0 0 0 0 O o O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O M O 0) N 0) M M O �- 6) N CL CQ CA C0 C0 C0 u) CI) u) Cn u) CO u) C0 CO C D O W= (7) C0 - ' CO C0 M V O u) C.0 V N u7 M C ✓ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 M 0 0 0 V O ` M 0 0 0 0 V M Z W CD 00 v- C0 6) CD O CD W OD v- CD 6) CD O 0 0 0 C0 CD CD 0 0 0 0 0 0 0 0 0 00 (0 N CO 1O ODCD CD C D N 1� Cl) C D CO OD g O 6 O CO O W C O Cn Cn O V O CO CO 0 00 Co CO C' CO V CD CID CO y M C0 I- L. n S a « N N M M C ,- <- <- N N OD C 0 0 .- -- N N M N N N M M V V ® W F- N U Q 6) CD CO CD CO CD 6CO) C CO c0 OD Co CD CD CD CD CD C0 CD CD CD O 0 O CD CD u) u) co N N IN N C0 u) 1- co Imo- on N N CO «') C0 C0 C0 0 CD O u) C0 C0 C0 CI) O CD > I- .- .-- co co CO 1- n m ,- M CD CO CO 66 • • • 0 0 0 O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O X C0 u) CI) u) O CD CD un u) Lc, CC, CI) O• u) u) J CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD } .- v- v- , CV N N r- .- r- r r- CO N N 0- QD OD CD v- 4 c- CO I� CO CD m C CO 0, UC CD C0 4 N CD M V N 7 u) d' N CD 00 C J d = CO u) C0 u) V CD 1- CO O 6 6 CI) V O p Cl U) U V 00 t` O M '.q O C W CA 1s- O eD 0 Co F- In "') v- C N v- V r V r" T- C O 0 0 0 t- O ti C D 6) O O O N O O O O O O N, CO CC Q N N N N J m ,- cp CV up QD W W r- .-- QD oD 00 QD r O 1- m IT. W O CD CD O ti ti 6 06 6 OJ 00 CA 6 O O O I- U (n CD CD CD CD 0 0 N CD CD CD CO CD 0 CO I` 4.1 QD QD LIDuLi,i C CO CO CO OD OD C0 LID QD OD <D O ta 4„, cC co co O COCD CD CD CD CD N- N CO O� CD CD NOD N-UD OM COLID CD N RC L., DC N N- .- r- M 0, OD N- N- 00r- 00 CD CO CO S. CD 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a) o o ,- r o 0 0 ' 0 0 0 CDCO C CD CD CD CD 0 0 CD CD CDi CO CD Ca CD CD CV C0 C) CD CD CD CD CDCON 40 C0 C✓ Z 0 0 0 CD u) 0 0 0 0 u) CV oD CV 00 OD U I- r � � � (� � � Qsw � rr � r O C0 C0 N CD os 4 O CQ u) C0 N CD COCD C 4 mooC4 (9 C CO C0 CO C CO N C C6 u) u) C0 C CO N- .O Ci 0 O O O C' o O O O O O C O O O 0 /y i' C' CO CO O v- CO 6) CO C0 C0 C)D 00 CO v \/ Q C0 M M C C9 N C0 CO M CO n) M u) M ,, U Cn 4 4 V . u) Cn Ct) Y 4 4 4 V CD Cn U Q CJ) CO CD CO W CD 1O CD CD CO CO c0 CD CO 1` . • CO C0 u) C D C0 COCOCD C0 CO C0 ClC0 QD CO ECO �C It N ry C w a) 0) CD N cO ) 0 0 p O O CO CO,- C` O O CD O 1:/ N O CV O c0 C. (I) I- OO CO CD CO OD C' o Co CO V CO OO Q V (n O N 0 0 0 0 0 oD N N 0 0 0 0 �// Z O O O F- C CD cP M C u, co a O ,- t0 CO V' c0 CD �1�1 Z 'n. Z O O O V Z O Z Z % C 0 4.) h- (1) CO U N J E n o a a N o u_ 0) g S N 2 cC Illikillb , 09/29/2017 5-1-2013 Page 23 HB IA ASPEN BUILDING DEPARTMENT 4/ • COIL CONNECTION DIMENSIONS Two Hydronic Coils, Preheat FIRST COIL SECOND COIL CONDENSATE RETURN SUPPLY RETURN SUPPLY DRAIN(314"FPT) CONFIGURATION UNIT SIZE A J R B H V C J S D G T E F 04/06 5.6 7.5 0.625 6.5 3.3 0.625 8.9 7.5 0.750 11.5 2.7 0.750 11.6 1.1 1HW 4CW 08112 5.4 14.1 0.625 5.4 5.5 0.625 7.7 9.8 0.750 10.3 5.5 0.750 10.6 1.1 16120 4.3 11.8 0.880 5.4 5.5 0.880 7.8 11.8 1.130 10.4 5.5 1.130 10.5 1.1 04106 5.6 7.5 0.750 6.5 3.3 0.750 9.0 7.5 0.750 13.5 3.3 0.750 11.6 1.1 1HW 6CW 8 5.4 14.1 0.625 5.4 5.5 0.625 7.7 9.8 0.750 12.0 5.5 0.750 10.6 1.1 12 5.4 14.1 0.625 5.4 5.5 0.625 7.7 9.8 0.875 12.1 5.5 0.875 10.6 1.1 16/20 4.3 11.8 0.880 5.4 5.5 0.880 7.8 11.8 1.130 12.2 5.5 1.130 10.5 1.1 04106 5.6 7.5 0.750 6.5 3.3 0.750 8.9 7.5 0.750 11.5 2.7 0.750 11.6 1.1 08/12 4.3 9.9 0.880 5.4 5.6 0.880 7.8 9.8 0.750 10.4 5.5 0.750 10.6 1.1 16 4.3 11.8 0.880 5.4 5.5 0.880 7.8 11.8 1.130 10.4 5.5 1.130 10.5 1.1 2HW 4CW 20 4.3 11.8 1.130 5.4 5.5 1.130 7.8 11.8 1.130 10.4 5.5 1.130 10.5 1.1 30 4.3 14.0 1.125 5.4 5.2 1.125 8.1 14.0 1.125 11.4 5.2 1.125 10.7 0.9 40 4.6 17.6 1.125 5.7 4.9 1.125 8.3 17.7 1.375 11.5 4.9 1.375 10.7 0.9 60 5.4 21.6 1.125 6.5 6.8 1.125 8.9 21.6 1.375 13.5 6.8 1,375 11.7 1.1 80 5.5 13.1 1.125 6.6 7.4 1.125 9.2 13.1 1.625 12.5 7.4 1.625 12.8 1.2 04/06 5.6 7.5 0.750 6.5 3.3 0.750 9.0 7.5 0.750 13.5 3.3 0.750 11.6 1.1 8 4.3 9.9 0.880 5.4 5.6 0.880 7.8 9.8 0.750 12.1 5.5 0.750 10.6 1.1 12 4.3 9.9 0.880 5.4 5.6 0.880 7.8 9.8 0.875 12.2 5.5 0.875 10.6 1.1 2HW 6CW 16120 4.3 11.8 1.130 5.4 5.5 1.130 7.8 11.8 1.130 12.2 5.5 1.130 10.5 1.1 30 4.3 14.0 1.125 5.4 5.2 1.125 8.1 14.0 1.375 13.5 5.2 1.375 10.7 0.9 40 4.6 17.6 1.125 5.7 4.9 1.125 8.3 17.7 1.630 13.7 4.9 1.630 10.7 0.9 60 5.4 21.6 1.125 6.5 6.8 1.125 9.0 21.6 1.625 14.4 6.8 1.625 11.7 1.1 80 5.5 13.1 1.125 6.6 7.4 1.125 9.2 13.1 1.625 14.6 7.4 1.625 12.8 1.2 04106 5.5 7.5 0.750 8.1 2.7 0.750 10.5 7.5 0.750 13.1 2.7 0.750 11.6 1.1 _08/12_ 4.3 9.8 0.750 6.9 5.5 0.750 9.3 9.8 0.750 11.9 5.5 0.750 10.6 1.1 16120 4.3 11.8 1.130 6.9 5.5 1.130 9.3 11.8 1.130 11.9 5.5 1.130 10.5 1.1 4HW 4CW 30 4.4 14.0 1.125 7.7 5.2 1.125 10.3 14.0 1.125 13.5 5.2 1.125 10.7 0.9 40 4.6 17.7 1.375 7.9 4.9 1.375 10.5 17.7 1.375 13.7 4.9 1.375 10.7 0.9 60 5.2 21.6 1.375 9.9 6.8 1.375 11.1 21.6 1.375 15.7 6.8 1.375 11.7 1.1 80 5.5 13.1 1.625 8.8 7.4 1.625 11.4 13.1 1.625 14.6 7.4 1.625 12.8 1.2 04/06 5.5 7.5 0.750 8.1 2.7 0.750 10.6 7.5 0.750 15.1 3.3 0.750 11.6 1.1 8 4.3 9.8 0.750 6.9 5.5 0.750 9.3 9.8 0.750 13.7 5.5 0.750 10.6 1.1 12 4.3 9.8 0.750 6.9 5.5 0.750 9.4 9.8 0.875 13.7 5.5 0.875 10.6 1.1 4HW 6CW 16120 4.3 11.8 1.130 6.9 5.5 1.130 9.4 11.8 1.130 13.7 5.5 1.130 10.5 1.1 30 4.4 14.0 1.125 7.7 5.2 1.125 10.3 14.0 1.375 15.7 5.2 1.375 10.7 0.9 40 4.6 17.7 1.375 7.9 4.9 1.375 10.5 17.7 1.630 15.9 4.9 1.630 10.7 0.9 60 5.2 21.6 1.375 9.9 6.8 1.375 11.2 21.6 1.625 16.6 6.8 1.625 11.7 1.1 80 5.5 13.1 1.625 8.8 7.4 1.625 11.3 13.1 1.625 16.7 7.4 1.625 12.8 1.2 04/06 5.6 7.5 0.750 10.1 3.3 0.750 12.3 7.5 0.750 14.9 2.7 0.750 11.6 1.1 8 4.3 9.8 0.750 8.7 5.5 0.750 11.1 9.8 0.750 13.7 5.5 0.750 10.6 1.1 12 4.4 9.8 0.875 8.7 5.5 0.875 11.1 9.8 0.750 13.7 5.5 0.750 10.6 1.1 6HW 4CW 16/20 4.4 11.8 1.130 8.7 5.5 1.130 11.1 11.8 1.130 13.7 5.5 1.130 10.5 1.1 30 4.4 14.0 1.375 9.8 5.2 1.375 12.4 14.0 1.125 15.7 5.2 1.125 10.7 0.9 40 4.6 17.7 1.630 10.0 4.9 1.630 12.6 17.7 1.375 15.9 4.9 1.375 10.7 0.9 60 5.3 21.6 1.625 10.7 6.8 1.625 13.2 21.6 1.375 17.9 6.8 1.375 11.7 1.1 80 5.5 13.1 1.625 10.9 7.4 1.625 13.5 13.1 1.625 16.8 7.4 1.625 12.8 1.2 REC WED Refer to Leger{9nfv it 017 s--zoi3 Page 26 HB 1.4 ASPEN ¶JILDING DEPARTMENT • • TYPICAL WIRING - i i I a 9 4 c,,...#4 I in,,4 2.,:,o MOTOR START/STOP STATION (MSS) OPTION Components shown are factory-provided and installed with the MSS option. Single Phase, Relay Control ill—. • . 0 GND GRN„42 USE COPPER SUPPLY WIRES. WHT„40 N 3, NHT„3, T ' •RED/500 Dl,SC\BL33 RU(„33 J [ .BRN/501 • A. Lt V' BLN7,3apr rr TBI rn R 0 RED/500 Refer to motor Cc, BRN/505 nameplate for GQm BL0502 wiring details. BLK„34°�~°aLK„a, BLK„4, FAN wHT„4, REFER TO NAMEPLATE I �"-BRw MOTOR BLK/ FOR PROPER VOLTAGE wz �U/ © FR I BRNrsUI GRWI42 HIGHVOLTAGE r_.m....1 Note: Single phase units may utilize a contactor instead of a relay. FACTORYWIRING LOW VOLTAGE Three Phase,Contactor Control FACTORY WIRING '1(--• • • 0 GND GRN„42 FIELD WIRING USE COPPER SUPPLY WIRES. DISCI L3. . BLU„36 0 YEU131 TR" .RED/500 3 Phase L2. • 0_f._ YEL/13, ((CC `-' �YEUIIS y N NOTES: Li. • CY BLK„33 BLK/133 `l1 RRwsot I. These diagrams represent the BL" '° A factory-installed MSS option. TB, If the j-box option is provided, R0 RED/500 Refer to motor nameplate for an arrangement like this may be CI BRN/Sos ___-_ -- __ --------- wiring details. Go BLK502 field-provided and installed to allow BLU„3e ORN/142 ¢I1-0 the customer's controls to start VEV135 OH 1_0 REDIIao FAN MOTOR GRN„43 and stop the fan. Selection of field B1JX„34^ , tt 8LK„4, RRN505 provided and installed electrical RLK/502 o EG dBHwSo, components is the responsibility of the installer. 2. MSS provides single-speed fan motor control and includes Three Phase,Starter Control lockable,non-fused disconnect switch,75VA 24V control ill- • • • 0 GND GR transformer,fan relay or contactor USE COPPER or starter(with overload if SUPPLY WIRES. required),low voltage terminal 1 L3• • •�UISCU BLU„35 block and indoor enclosure. mil,Imil, TRAM .RED/SOD 3. Typical wiring is shown.For exact YEU131 3 Phase Lz• O "i,YE1/135 ' wiring,refer to the wiring diagram Lt• • o-' BLK/133 A eRwso, provided with the unit. 4. Factory-installed electric heat Tel includes the functionality of the R00 RED/500 I MSS,so MSS is not required. c� sup 505 5. Refer to the following pages for G 00 Refer to motor j-box and electric heat options. nlate for wiring details. 6. Units ordered for 208V 240V BLU„36 f__00.0 0131.0142 1 voltage sele is-ED FTN GRN1103 for 240V.Fi � I muj 4 o_i1_,x-l'., 0 MOTOR BLK/134 c ' djj BLK„41 and transfo rifa !-•f•' BLK/502 h..l, o.R"N/ operation at 208V. BRNI501 09/29/2017 5-1-2013 Page 29 FIB IA ASPEN BUILDING DEPARTMENT HB Series Airside Pressure Drop Unit Size CFM FLAT FILTERS ANGLED FILTERS DISCHARGE PLENUM MIXING BOX STD T/A PLEATED STD T/A PLEATED 0 DEG DEF 45 DEG DEF 300 0.04 0.05 0.03 0.02 0.01 0.02 0.01 HBB-04 400 0.05 0.07 0.03 0.03 0.02 0.04 0.02 500 0.07 0.10 0.05 0.04 0.04 0.06 0.03 450 0.06 0.08 0.04 0.04 0.03 0.05 0.02 HBB-06 600 0.09 0.13 0.06 0.05 0.05 0.08 0.04 750 0.13 0.18 0.08 0.07 0.08 0.13 0.06 600 0.06 0.06 0.04 0.03 0.01 0.02 0.01 HBB-08 800 0.09 0.09 0.05 0.05 0.02 0.04 0.02 1000 0.12 0.12 0.07 0.06 0.04 0.06 0.03 900 0.11 0.10 0.06 0.06 0.03 0.05 0.02 HBB-12 1200 0.16 0.16 0.09 0.08 0.05 0.09 0.04 1500 0.21 0.23- 0.12 0.12 0.08 0.14 0.07 1200 0.09 0.08 0.06 0.06 0.02 0.03 0.02 HBB-16 1600 0.13 0.13 0.09 0.09 0.03 0.05 0.03 2000 0.17 0.18 0.12 0.12 0.05 0.09 0.04 1500 0.12 0.12 0.08 0.08 0.03 0.05 0.02 HBB-20 2000 0.17 0.18 0.12 0.12 0.05 0.09 0.04 2500 0.24 0.26 0.17 0.17 0.08 0.13 0.07 2250 0-07 0.06 0.06 0.06 0.03 0.05 0.03 HBB-30 3000 0.10 0.10 0.09 0.09 0.05 0.09 0.05 3750 0.13 0.14 0.12 0.12 0.09 0.14 0.08 3000 0.10 0.10 0.09 0.09 0.05 0.09 0.05 , HBB-40 4000 0.15 0.15 0.13 0.14 0.10 0.16 0.09 5000 0.20 0.21 0.18 0.19 0.15 0.24 0.14 5000 0.12 0.12 0.11 0.11 0.06 0.10 0.09 HBB-60 6000 0.15 0.16 0.14 0.14 0.09 0.14 0.12 7000 0.19 0.20 0.17 0.18 0.12 0.20 0.17 7000 0.14 0.14 0.12 0-12 0 05 0-08 0.13 HBB-80 8000 0.17 0.18 0.15 0.15 0.06 0.10 0.17 9000 0.20 0.21 0.17 0.18 0.08 0.12 0.21 Unit Size Blower Size CHILLED WATER/HOT WATER DX Steam CFM 1 ROW 2 ROW 4 ROW 6 ROW Std Cap High Cap Std Cap High Cap 300 0.00 0.01 0.01 0.04 0.10 0.17 0.04 - HBB-04 9 X 67 400 0.02 0.04 0.09 0.16 0.21 0-35 0.07 - 500 0.04 0.08 0.16 0.28 0.33 0-53 0.10 - 450 0.02 0.04 0.08 0.14 0.08 0.14 0.08 - HBB-06 9 X 6T 600 0.04 0.09 0.17 0.30 0.17 0.30 0.13 - 750 0.07 0-13 0.27 047 0.27 0-47 0.20 - 600 0.05 0.11 0.17 0.28 0.14 0.28 0.05 0.09 14B8-08 9 X 6 800 0.09 0.18 0.23 0.39 0.25 0.39 0.08 0.15 1000 0.13 0.27 0.30 0.52 0.38 0.52 0.12 0.22 900 0.03 0.06 0.12 0.23 0.09 0.23 0.05 0.09 HBB-12 9 X 6 1200 0.06 0.11 0.16 0.32 0.17 0.32 0.08 0.15 1500 0.08 0.16 020 0-41 027 0-41 0.12 0-22 1200 0.01 0.02 0.14 0.26 0.12 0.26 0.05 0.10 HBB-16 12 X 6 1600 0.03 0-05 0.19 0.35 0.21 0-35 0.09 0.16 2000 0.05 0.09 0.25 0.46 0.32 0.46 0.13 0.24 1500 0.03 0.06 0.11 0.23 0.09 0.23 0.05 0.10 HBB-20 12 X 9 2000 0.04 0.08 0.15 0.31 0.17 0.31 0.09 0.16 2500 0.05 0.10 0.19 0.41 0.26 0.41 0.13 0.24 2250 0-06 0.17 0.29 0.15 0.29 0.05 0.10 HBB-30 15 X 9 3000 0.12 0.23 0.40 0.27 0.40 0.09 0.17 3150 0.13 0.25 0.43 0.29 0.43 0.10 0.18 3750 0-18 0.31 0.53 0.40 0.53 0.13 0.24 3000 0.07 0.14 0.26 0.10 0.26 0.05 0.10 HBB-40 15 X 9 4000 0.10 0.19 0.36 0.18 0.36 0.09 0.16 5000 0.13 0.25 0.48 0.28 0.48 0.13 0.23 5000 0.08 0.17 0.31 0.19 0.34 0.06 0.12 HBB-60 15 X 12(2) 6000 0.10 0.21 0.39 0.27 0.48 0.08 0.16 7000 0.12 0.25 0.47 0.36 0.63 0.11 0.21 7000 0.09 0.18 0.34 0.35 0.46 0.05 0.09 HBB-00 15 X 12(2) 00 0.12 0.24 0.46 0.56 0.70 0.07 0.14 RECE IV ED NOTES: 1. All values are in inches wc. 2. All pressure drops are with dry coil. 0 9/2 9/2 017 5-1-2013 Page 33 HB 1.4 ASPEN BUILDING DEPARTMENT iiii • • BELT DRIVE UNIT ® MOTOR SPECIFICATIONS General: Factory provided and installed motors are single speed. Motor Electrical Data: general purpose motors suitable for HVAC applications, rated for Motor data provided in this data 725rpm or 1750rpm,single speed. Two speed,two-winding motors table is the motor manufacturer's are also available,with nominal ratings of 1 140rpm at low speed and rated FLA data. Where more 1750rpm at high speed. FLA rating below is at high speed. than one manufacturer provides Efficiency: Single phase motors comply with EPACT motor efficiency the same size motor/voltage,the requirements. All three-phase motors comply with EISA motor efficiency highest value is reported in the requirements,and are NEMA Premium rated for sizes I hp through I0hp. table. Inverter Ready: Three phase motors I hp through I0hp are Where data is provided for only Inverter Ready,meaning that they pass and are marked compliant one voltage,other voltages are not with NEMA MG I Part 3 I test for use with variable frequency drives available for that particular motor (VFD's). Inverter Ready motors are suitable for use down to I/6th of selection (ie:if only 240V is listed, synchronous speed, minimum. NOTE: Compliance with the standard then the motor is not rated for does not imply that the motor is suitable for use with a specific drive. operation at 208V). For guaranteed matching of motor and VFD,consult your VFD supplier WARNING: Field-provided for matched motor and VFD set. and installed motors may have different electrical Belt Drive Motor Electrical Data characteristics and different MC I HP I MV 1 I MA 1 1 MV 2 I MA 2 MC HP MV 1 MA 1 MV 2 MA 2 specifications. AA No motor K2 0.75 208/3 2.8 240/3 3 B1 0.25 208/1 3 240/1 2.6 K3 1 460/3 1.8 131 0.25 115/1 5.3 K3 1 208/3 3.9 240/3 3.7 B2 0.33 208/1 2.9 240/1 3.3 K4 1.5 460/3 2.3 B2 0.33 115/1 6.6 K4 1.5 208/3 5.3 240/3 5 B3 0.5 208/1 4.8 240/1 4.3 K5 2 460/3 3 B3 0.5 115/1 8.8 K5 2 240/3 5.8 84 0.75 208/1 6.5 240/1 6.6 K6 3 460/3 4 B4 0.75 115/1 13.3 K7 5 460/3 6.4 85 1 208/1 7.4 240/1 7.4 K7 5 240/3 12.8 BS 1 115/1 15 L1 0.5 460/3 0.9 B6 1.5 208/1 9.4 240/1 9 L1 0.5 208/3 1.8 240/3 1.8 B6 1.5 115/1 18 L2 0.75 460/3 1.2 B7 2 208/1 10.9 240/1 11 L2 0.75 208/3 2.5 240/3 2.4 87 2 115/1 22 L3 1 460/3 1.6 Cl 0.5 240/1 2.3 L3 1 208/3 3.2 240/3 3.2 LEGEND Cl 0.5 115/1 4.6 L4 1.5 460/3 2.4 C2 0.75 240/1 4.4 L4 1.5 208/3 4.6 240/3 4.8 MC: Motor code(Voltage/Phase) C2 0.75 115/1 8.8 15 2 460/3 2.9 C3 1 240/1 5.7 L5 2 208/3 6 240/3 5.8 HP: Horse power C3 1 115/1 11.4 L6 3 460/3 4.3 El 0.5 115/1 8.2 L6 3 208/3 8.7 240/3 8.6 FLA: Full Load Amps E2 0.75 115/1 9 L7 5 460/3 6.8 E3 1 115/1 10.8 L7 5 208/3 14.4 240/3 13.6 MV1: First operating voltage 91 0.5 240/1 4.1 L8 7.5 460/3 9.9 F2 0.75 208/1 4.3 240/1 4.4 L8 7.5 208/3 20.6 240/3 19.8 MV2: Second operating voltage F3 1 208/1 5.4 240/1 5.3 L9 10 460/3 12.8 G1 0.25 277/1 2.1 L9 10 208/3 28.5 240/3 25.6 MA1: Motor FLA at First operating G2 0.33 277/1 2.5 Ni 0.5 0.8 G3 0.5 277/1 3.6 N2 0.75 1.2 voltage G4 0.75 277/1 5.4 N3 1 1.2 G5 1 277/1 6.7 N4 1.5 1.8 MA2: Motor FLA at Second oper- _ G6 1.5 277/1 8.5 NS 2 575/3 2.3 G7 2 277/1 8 N5 3 3.4 ating voltage P I<1 0.5 460/3 1.1 N7 5 5.4 KE( Cl K1 0.5 208/3 2.4 240/3 2.8 N8 7.5 7.5 K2 0.75 460/3 1.3 NO 10 10.1 0 9/2 9/2 017 5-1-2013 Page 34 HB IA ASPEN 'BUILDING DEPARTMENT ': fantech° a systemair company SHR 1504 FRESH AIR APPLIANCE Document type: Product card Document date: 2016-12-16 Item no. 40072 Generated by: Systemair Online Catalogue Description • Airflow up to 149 cfm @ 0.4"PS serves 3-5 bedroom homes • Three speed ventilation control • External dry contacts for quick connection of remote controls • Compatible with Fantech's low-voltage controlsNIP — • Easy access service door Application Fantech's side port connection HRV for budget conscious house projects. How it works the SHR 1504 unit brings a continuous supply of fresh air into a home while exhausting an equal amount of contaminated air.During winter,fresh incoming air is tempered by the heat that is transferred from the outgoing air so you save on energy costs,while during summer,the incoming air is pm-cooled if the house is equipped with an air cooling system.The SHR 1504 is equipped with automatic defrost mechanisms so you can use your HRV all year long. Defrost cycle •• A preset defrost sequence is activated at an outdoor air temperature of 23°F and lower.During the defrost sequence,the supply blower shuts down&the exhaust blower switches to high speed to maximize the effectiveness of the defrost strategy. The unit then returns to normal operation,and continues the cycle. Technical parameters Nominal data Voltage 120 V Frequency 60 Hz Phase 1 — Rated power 156 W Current 1.3 A Airflow high 149 cfm Static pressure 0.4 in.wg Certificate CSA.HVI Weight 45.2 lbs. Energy performance Supply Net Consumed Sensible Apparent Latent temperature airflow power recovery sensible recovery/moisture Heating efficiency effectiveness transfer (°C) cfm(Us) W % % - 32(0) 67(31) 72 60 73 -0.11 32(0) 109(51) 98 59 70 0.00 32(0) 161(76) 144 55 63 0.00 -13(-25) 68(32) 73 56 77 -0.02 Dimensions EC WED 09-2912017 Name:SHR 1504 FRESH MR APPLIANCE I Item no.:40072 1/4 Document type:Product card I Document date:2016-12-16 I Generated by:Online catalogue ASPEN BUILDING DEPARTMENT 0 )i 3r • t. H e I 1 (.,--- +- e • A B C D E Duct Size 2 1/4(57) 23 1/3(597) 2 5/8(67) 17 3/8(441) 16 1/8(410) 6(152) 1 Dimensional information is in inche(mm) Wiring I c.n gi a +w t • mix_ " SUP 1 ) .c irk Y D.M 4—IL - 1 IA, ':-:. ELL °' Li�, t,iJic, Ext i d b ILO 1.1 asT T .4 °j o T t d WTE Cut orr rrroY► i:? i m = ;,v U. 4 an prten ii 4nd er.u: F" ,� ena coniry sores wii 59 0 0 1 Iww,srn.+o.ne+ ; j _ > L� 1 /§I JUMPER SETTINGS /_ 14111 ibel, NOTE: ITEMS DRAWN OR CIRCLED IN DASHED LINES ARE ONLY AVAILABLE OF CERTAIN MODELS Accessories Electric accessories EDF1 Multi-Func Ctrl(40375) RTS3 Pushbutton Timer(40376) MDEH1 Low Voltage Dehumidistat(40172) RTS2 Pushbutton Timer(40164) EDF7 Elec Multi-Funct Dehum(44883) ECO-TOUCH Pgrm Wall Control(44929) Accessories MGE 5 Metal Exhaust Grill(411370) MGE 6 Metal Exhaust Grill(411371) MGS 4 Metal Supply Grill(411368) MGS 5 Metal Supply Grill(411369) RE;E IVE D MGS 6 Metal Supply Grill(411242) Name:SHR 1504 FRESH AIR APPLIANCE I Item no.:40072 0 9/2 9i/2 017 Document type:Product card I Document date:2016-12-16 I Generated by:Online catalogue ASPEN BUILDING DEPARTMENT MGE 4 Metal Exhaust Grill(411106) FIDT 4 Insulated Flex Duct(411061) FIDT 5 Insulated Flex Duct(411062) FIDT 6 Insulated Flex Duct(411064) COM6P Supply and Exhaust Hoods(40222) Documentation ilk405190 Residential VHR-SHR Installation Manual.pdf(2.33MB' 6405191 SHR VHR Homeowner's Manual EN FR.pdf(1,15MB) SHR Series Service Manual.pdf(160,49kB) SHR1504.rfa(656,00kB) 11403787 SHR1504 Spec Sheet EN.pdf(388,98kB) Performance Diagrams Supply Extract -x 1.5 1.5 co NNNNc c NNN 0.5 0.5 40 80 120 160 200 40 80 120 160 200 tcfm] O tcfm] Diagrams and calculations are made for the performance with clean filters. Specification text Fans Two(2)factory-balanced fans with backward curved blades.Motors come with permanently lubricated,sealed ball-bearings to guarantee long life and maintenance-free operation. Heat Recovery Core Aluminum heat recovery core covered by a limited lifetime warranty.Core dimensions are 9°x 9"(229 x 229 mm)with a 15'(380 mm)depth.Our heat exchangers are designed and manufactured to withstand extreme temperature variations. Frost Control -1 preset frost control sequence is activated at an outdoor air temperature of 23°F(-5°C)and lower.During the defrost sequence,the supply blower shuts down&the exhaust blower switches into high speed to maximize the effectiveness of the defrost strategy.The unit then returns to normal operation,and continues cycle. Serviceability Core,filters,fans and drain pan can be easily accessed through latched door.Core conveniently slides out on our new easy glide core guides. 17"(432 mm)of clearance is recommended for removal of core. Case 24 gauge galvanized steel.Baked power-coated paint for a superior adhesion and resistance. Insulation Cabinet is fully insulated with 1'(25 mm)high density expanded polystyrene Filters Two(2)washable electrostatic panel type air filters 8.5"(216mm)x 15'(380mm)x 0.125'(3mm). Controls External three(3)position(Low/Stand By/Medium)rocker switch that will offer continuous ventilation.Fantech offers a variety of external controls. (see accessories) Installation Unit is typically hung by using installation kit supplied with unit.Mounting bolts provided on top four(4)corners of unit. WEDWarrantyREC Name:SHR 1504 FRESH AIR APPLIANCE I Item no.:40072 0 9/2 912 0 1 7 Document type:Product card I Document date:2016-12-16 I Generated by:Online catalogue ASPEN BUILDING DEPARTMENT Limited lifetime on aluminum core,7 year on motors,and 5 year on parts. Requirements and standards • Complies with the UL 1812 requirements regulating the construction and installation of Heat Recovery Ventilators • Complies with the CSA C22.2 no.113 Standard applicable to ventilators • Complies with the CSA F326 requirements regulating the installation of Heat Recovery Ventilators • Technical data was obtained from published results of test relating to CSA C439 Standards • HVI certified RECEIVED Name:SHR 1504 FRESH AIR APPLIANCE I Item no.:40072 0 9/2 9//2 017 Document type:Product card I Document date:2016-12-16 I Generated by:Online catalogue ASPEN BUILDING DEPARTMENT ": fantech` a sysremair company VHR 2005R FRESH AIR APPLIANCE Document type: Product card Document date: 2016-12-16 Item no. 40063 Generated Or Systemair Online Catalogue Description • Airflow up to 201 cfm @ 0.4"PS serves 7 bedroom homes • Three speed ventilation control • Compatible with Fantech's low-voltage controls 111.111111 • External dry contacts for quick connection of remote controls Application nun Fantech's larger residential,full-featured HRV for large house projects that demand higher efficiency,the VHR2005R is designed for higher statis pressure and higher ZZ;;►, airflow applications.During winter,fresh incoming air is tempered by the heat that is transferred from the outgoing air so you save on energy costs,while during summer, the incoming air is pre-cooled if the house is equipped with an air cooling system. The VHR 2005R is equipped with a recirculation defrost mechanism so you can use your HRV all year long. How it works During the defrost sequence,a motorized damper temporarily blocks the incoming fresh air stream so that the warm air from the house can circulate through the HRV. 111 The exhaust blower shuts down and the supply blower switches into high speed to maximize the effectiveness of the defrost strategy.During this cycle,household odors from the kitchen or bathroom are prevented from entering the home and the unit will 0 not create negative pressure. Technical parameters Nominal data Voltage 120 V Frequency 60 Hz Phase 1 - Rated power 228 W Current 1.8 A Airflow high 201 cfm Static pressure 0.4 in.wg Certificate CSA,HVI Weight 61.7 ios Energy performance Sensible Latent Supply Consumed Apparent sensible recovery/ Net airflow recovery temperature power efficiency effectiveness moisture Heating transfer (°C) cfm(L/s) - I 32(0) 65(31) 108 62 77 0.06 32(0) 117(55) 154 62 74 0.07 32(0) 191(90) 246 60 71 0.00 -13(-25) 126(59) 141 64 81 0.01 Dimensions RECEIVED 09/29//2017 Name;VHR2005R FRESH AIR APPLIANCE I Item no.:40063 Document type:Product card I Document date:2016-12-16 I Generated by:Online catalogue ASPEN BUILDING DEPARTMENT D ! mni • —011111111111111111111115 ,.„.1 .e� tta.i C I f 1 i A B C D Duct Size 1 28(711) 17 1/4(438) 20 1/2(523) 2 1/4(57) 6(152) Dimensional information is in inches(mm) Wiring .ai fit✓ , .� •LiU_P) (D.M L' y-ii' .I _ -ir- f `t 1ttig 1-. ' o o;Q -to al Ia or 12 Y i - , i I f f E I ikfin MI f 1 r-2 ate^.ILL G ®{`) 1.LA ii� i t f� �01311, n f ` • l�.v III T r ....T. t a. 1 2 �...-f F —) iearsfoe+ ,-,t L , . Fligad 0 T i , "T KITE,O.st off fooai. ..._ cra•t.rwrnt cr.proem $ t g 1 erw ca- .rr, wt - ,ate - ene co�err eves etn �� I � I 0 �n tlMN er.Y etAf n.. +.+vtr tra• ct•-�.f- StS '_ .y, .« �i t� T p JUMPER SETTINGS 4"3-iL Ali lIT NOTE: ITEMS DRAWN OR CIRCLED IN DASHED LINES ARE ONLY AVAILABLE OF CERTAIN MODELS Accessories Electric accessories EDF1 Multi-Func Ctrl(40375) /� ERTS3DF1 Pushbutton Timer( ) RECEIVED EDF1 R Multi-Punt Ctrl w Recirc(40393) MDEH1 Low Voltage Dehumidistat(40172) Name:VHR 2005R FRESH AIR APPLIANCE I Item no.:40063 0 9/2 9//2 017 Document type:Product card I Document date:2016-12-16 I Generated by:Online catalogue ASPEN BUILDING DEPARTMENT RTS2 Pushbutton Timer(40164 EDF7 Elec Multi-Funct Dehum(44883) ECO-TOUCH Pgrm Wall Control(44929) Accessories MGE 5 Metal Exhaust Grill(411370) MGE 6 Metal Exhaust Grill(411371) MGS 4 Metal Supply Grill(411368) MGS 5 Metal Supply Grill(411369) MGS 6 Metal Supply Grill(411242) MGE 4 Metal Exhaust Grill(411106) FIDT 4 Insulated Flex Duct(411061) FIDT 5 Insulated Flex Duct(411062) FIDT 6 Insulated Flex Duct(411064) COM6P Supply and Exhaust Hoods(40222) Documentation 11405190 Residential VHR-SHR Installation Manual.pdf(2,33MB) 11405191 SHR VHR Homeowner's Manual EN FR.pdf(1,15MB) VHR2004-2005R Service Manual.pdf(167,30kB) 403795 VHR2005R Spec Sheet EN.pdf(451.49kB' Performance Diagrams Supply Extract 25 25 2 1-5 3 1.5 I acri . 1 50100 150 200 250 300' 0 50 100 150 200 250 300 0 tcfrnl 0 Icfm] Diagrams and calculations are made for the performance with clean filters. Specification text Fans Two(2)factory-balanced fans with backward curved blades.Motors come with permanently lubricated,sealed ball-bearings to guarantee long life and maintenance-free operation. Heat Recovery Core Aluminum heat recovery core covered by a limited lifetime warranty.Core dimensions are 12°x 12'(305 x 305 mm)with a 15'(380 mm)depth.Our heat exchangers are designed and manufactured to withstand extreme temperature variations. Defrost The unit incorporates a unique and quiet internal recirculation defrost that does not depressurize the home during the defrost cycle.A preset defrost sequence is activated when the outdoor temperature falls below 23°F(-5°C)and automatically adjusts itself based on operating conditions.The fan speed is also adjusted automatically to provide a smooth and quiet transition between Ventilation&Defrost mode. Serviceability Core,fitters,fans and drain pan can be easily accessed through latched door-Core conveniently slides out on our new easy glide core guides. 17"(432 mm)of clearance is recommended for removal of core. Duct Connections 6'(152 mm)plastic duct connections with integrated balancing damper. Case 24 gauge galvanized steel.Baked power-coated paint for a superior adhesion and resistance. RECEIVED insulation Cabinet is fully insulated with 1"(25 mm)high density expanded polystyrene. Name:VHR 2005R FRESH AIR APPLIANCE(Item no.:40063 09/29/324017 Document type:Product card I Document date:2016-12-16 I Generated by:Online catalogue ASPEN BUILDING DEPARTMENT Filters Two(2)washable electrostatic panel type air filters 11.75"(298mm)x 15"(380mm)x 0.125°(3mm). Controls External three(3)position(Low/Stand By/Medium)rocker switch that will offer continuous ventilation.Fantech offers a variety of external controls. (see accessories) Installation Unit is typically hung by using installation kit supplied with unit.Mounting bolts provided on top four(4)corners of unit. Controls External three(3)position(Low/Stand By/Medium)rocker switch that will offer continuous ventilation.The product comes with ECO-Touch wall control panel. Warranty Limited lifetime on aluminum core,7 year on motors,and 5 year on parts. Requirements and standards • Complies with the UL 1812 requirements regulating the construction and installation of Heat Recovery Ventilators • Complies with the CSA C22.2 no.113 Standard applicable to ventilators • Complies with the CSA F326 requirements regulating the installation of Heat Recovery Ventilators • Technical data was obtained from published results of test relating to CSA C439 Standards • HVI certified RECEIVED Name:VHR 2005R FRESH AIR APPLIANCE I Item no.:40063 0 9/2 9/2 017 Document type:Product card(Document date:2016-12-16 I Generated by:Online catalogue ASPEN BUILDING DEPARTMENT