HomeMy WebLinkAboutFile Documents.600 E Main St.0214.2019 (23).ARBK ELECTRONIC FIREPLACE DAMPER Model: FSE Series epo ' us 1110 FdIE SENTINEL The Flue Sentinel° Electronic Fireplace Damper is designed to increase the comfort and energy efficiency of residential homes with gas-fired fireplaces.Consisting of a stainless steel pipe/blade assembly and solid-state controller housed in a weather-proof enclosure,the damper is installed outdoors on the top of the chimney of a gas-fired fireplace.The damper automatically opens the flue outlet when the fireplace is turned on and automatically closes off the flue outlet when the fireplace is turned off. By closing off the flue outlet the fireplace is not in use,the damper prevents drafts and conserves energy by preventing heat in the home from escaping through an open flue. The Flue Sentinel®is design certified by the Canadian Standards Association (CSA)to CSA Requirement No.2.03- US for Automatic Vent Damper Devices for Use Outdoors on Fireplace Chimneys and is covered by U.S. Patent No. 6,915,799. AWARNING:Do NOT install this damper on a chimney burning solid fuel such as wood. Do NOT install this damper on a chimney used for venting central heating or water heating appliances. READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION. This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions.The definition of a qualified agency is:any individual,firm,corporation or company which either in person or through a representative is engaged in,and is responsible for,the installation and operation of HVAC appliances,who is experienced in such work,familiar with all the precautions required,and has complied with all the requirements of the authority having jurisdiction. Please retain these instructions after installation. Installed By: Phone: Installation Date: RECEIVED WGBY: FIELD CONTROLS 11/05/2019 SENTINEL www.fieldcontrols.com ASPEN BUILDING DEPARTMENT SPECIFICATIONS OPERATING SPECIFICATIONS Voltage(Range) 24VAC (Max 27.6, Min 20.4 VAC) Frequency 50/60 Hz Current(running) 80 mA Maximum current rating for output circuit 5A Operating Temperature Range Controller: (-40) 140°F Pipe: (-40) -650°F 7 seconds to open Timing 30-40 seconds to close (incl.time delay) 1 II IIIIIIII��IIIIIIIIIIIIh 0. s��IIIIIIIIIIIIIIIIIIIIIII�IIIIIIIIIIIIIII��II� C 10,11 4010A00 e ri j ., •�P o 170 I © O[ ° u !._. 11. ii Flue Sentinel° Dimensions and Weight-FSE-8 through FSE-16 MODEL DIM A DIM B DIM C I DIM D I WT. (LB) FSE-8 I 7.8 10.5 17.0 I 13.8 I 7.8 FSE-10 9.8 10.5 19.0 15.8 8.9 FSE-11 10.8 10.5 20.0 16.8 9.4 FSE-12 11.8 10.5 21.0 17.8 10.0 FSE-13 12.8 12.5 22.0 18.8 11.3 FSE-14 13.8 12.5 23.0 19.8 12.0 FSE-16 15.8 12.5 25.0 21.8 111./05/2 019 *AII dims are in inches page 2 ASPEN BUILDING DEPARTMENT ' El D 7„,1111 ,1 ,,,,,, pi, IN 47::: li , C k . . offI iiiii,..°1& ..►o 111 in 1:1_ a iju ["" A 11-1 Flue Sentinel® Dimensions and Weight- FSE-18 through FSE-24 MODEL DIM A DIM B DIM C I DIM D I WT. (LB) FSE-18 17.8 13.5 27 23.8 15.6 FSE-20 19.8 14.5 29.0 25.8 17.8 FSE-22 21.8 15.5 31.0 27.8 20.1 FSE-24 23.8 16.5 33.0 29.8 22.9 *AII dims are in inches RECEIVED 11/05/2019 page 3 ASPEN BUILDING DEPARTMENT INSTALLATION The Flue Sentinel®has been designed to fit a variety of chimney types including masonry and manufactured chimneys.It features a mounting collar that seals the chimney,adjustable legs for means of attachment and a crimped outlet for mounting the chimney top. Figure 1 is an example of a typical installation Installation of the Flue Sentinel®must comply with the following requirements • The Flue Sentinel°must be installed only on a factory built chimney or vent complying with a recognized standard,or a masonry or concrete chimney acceptable to the authority having jurisdiction. • The Flue Sentinel°must be located on a chimney so that it serves only the single fireplace appliance for which it is installed. • The Flue Sentinel°shall be installed in accordance with local codes,or in the absence of local codes,in accordance with the National Fuel Gas Code,ANSI Z223.1. • If the Flue Sentinel°is to be installed on an air-cooled chimney,it must be installed with the appropriate Flue Sentinel° Mounting Kit per the kit instructions. Installation Steps: 1. Set the damper in the opening of the chimney flue to check Chimney Top the fit.The damper's mounting collar should rest evenly on the Flue Sentinel top edge of the flue.Also check _ Mounting Leg the orientation of the damper Facade control housing and mounting *4-Wire Cable legs to ensure the proper \� �2"x a°Framing attachment and routing of the 1/2"Drywall or Sheetrock wiring harness. (See Local Code) 2. Remove the damper and apply a Notes bead of high temperature sealant on the top edge of the flue. "Typically 18/4.Run in conduit if required or if 3. Center the damper in the installed on exterior of Manufactured Chimney masonry chimney. opening of the chimney flue. 4. Adjust the mounting legs to "The Flue Sentinel®is Chase electrically interlocked rest on top of the chimney and with the main burner secure with screws.Tighten the valve/controls of the gas log set.See Basic mounting leg bolts at the collar Wiring Diagram on pg. Minimum Clearance to brackets. 5. Combustibles Per Chimney Manufacturer 5. Install the chimney top and On/Off y � secure per the manufacturer's Switch Ignition Gas Log Set instructions. Module not shown. 6. Install the warning tag on the damper wiring harness near gas valve.To identify the requirement 120/24V that the Flue Sentinel device be Transformer removed before converting to wood burning. **Gas Valve 1 Gas Line Figure 1 RECEIVED 11/05/2019 page 4 ASPEN BUILDING DEPARTMENT WIRING AWARNING:This damper device MUST be interlocked with all automatic gas valves on the fireplace appliance.DO NOT negate the action of any existing safety of operational control. The following requirements must be met to ensure safe and proper operation: • The Flue Sentinel®Electronic Fireplace Damper must be electrically connected to the fireplace appliance using the chimney upon which the damper is installed. • The damper must be installed in accordance with the NEC NFPA 70(most recent edition)and/or local codes. • The damper must be installed using the wiring harness supplied with it.This harness has a mated connector which plugs into the damper controller. • The damper's wiring harness must terminate at the gas valve. • The wiring connecting the damper controller to the gas valve must be a minimum of 18 AWG and must be run in conduit if installed on the exterior of the chimney or required by code. • Figure 2 is a wiring connection diagram for a typical installation with an intermittent ignition system. • The damper control wiring must always be connected as follows: Brown-24 VAC Hot Orange-Signal In Yellow-Signal Out Black -24 VAC Common Figure 2 IGNITION CONTROL MODULE 24V GND TH-W n n n SPARK ELECTRODE/ SENSOR GAS VALVE— _ I TRANSFORMER FIREPLACE HARNESS COLOR CODE SWITCH Standard Wire Connector High Temp Wire Connector 120 VAC 124 VAC # 2 4 2 4 L2 • 00 00 1 3 1 3 FLUE BLACK VIEW SHOWING VIEW SHOWING SENTINEL # END OF RECEPTACLE END OF RECEPTACLE ELECTRONIC BROWN ORANGE WIRE CONNECT WIRE CONNECT FIREPLACE YELLOW CODE COLOR tti DAMPER ,� .� �i, 1 BROWN Il twill €1 2 ORANGE 2 RED 4 ELLOOK 1.4gp/2019 page 5 ASPEN BUILDING DEPARTMENT SEQUENCE OF OPERATION When the fireplace is turned on,a 24V signal is sent by the fireplace control to the damper controller.The damper controller motor then rotates the damper blade,which is indexed to a cam,to the open position to allow products of combustion to pass through the flue outlet.The cam proves the damper is in the open position and switches 24V from the motor to the main gas valve or ignition system,which fires the main burner. When the fireplace is turned off,the fireplace control removes the 24V signal to the damper controller,shutting off the main burner.After a 30-40 second delay,the damper controller motor then rotates the damper blade to the closed position and resets itself for the next time the fireplace is turned on. FINAL INSPECTION Turn on the gas and electrical supplies to the appliance.Check the operation of the Flue Sentinel®by cycling the appliance at least three times as follows: 1. Switch the fireplace control to turn on the fireplace. 2. The damper will open and fire the main burner.The damper must be in the open position when appliance main burner is operating. 3. Switch the fireplace control to turn off the fireplace.The main burner will immediately shut off and,after approximately 30- 40 seconds,the damper will rotate to the closed position. If the Flue Sentinel°Electronic Fireplace Damper and/or fireplace appliance does not operate as described above,consult the Troubleshooting Chart below for the proper course of action to resolve the problem. TROUBLESHOOTING CHART PROBLEM POSSIBLE CAUSES ACTION No power or insufficient power at damper Check for opens in the power supply circuit and correct No signal into damper Check for opens in fireplace control/circuit and Damper won't gcorrect open Obstruction preventing damper blade from Check for protruding screws or binding in rotating pipe/blade assembly and correct Defective damper controller Replace controller Defective gas valve or ignition control on Check for power at gas valve and/or ignition Damper opens but appliance control. If present, replace defective part appliance main burner(s) does not If not present,check for power at control- fire Defective damper controller ler,yellow wire should be energized. If not, replace controller Damper rotates Defective damper controller Replace controller continuously Check for power at controller,only black and No power or insufficient power at damper brown wires should be energized. If not,check wiring diagram Damper won't close, main burner off Obstruction preventing damper blade from Check for protruding screws or binding in rotating pipe/blade assembly and correct Defective damper controller Replace controller Damper won't close, Fireplace control still sending signal to Check for shorts in fireplace control/circuit and main burner on damper to open correct 11/05/ 019 page 6 ASPEN BUILDING DEPARTMENT MAINTENANCE CAUTION:Label all wires prior to disconnection when servicing controls.Wiring errors can cause improper and dangerous operation. The Flue Sentinel®has been designed to provide years of maintenance free service.However,for continued safe operation, the Flue Sentinel®,chimney and fireplace appliance should be examined once a year by a qualified service agency.It is also recommended that the homeowner examine these components at least every(6)months,with particular attention given to deterioration from corrosion or other source RECEIVED 11/05/2019 page 7 ASPEN BUILDING DEPARTMENT WARRANTY For warranty about this or any Field Controls product, visit: www.fieldcontrols.com/warranty [LEI[ MFG BY: 41111110111110 SENTINEL FIELDCONTROLS RECEIVED Phone: 252.522.3031 • Fax: 252.522.0214 www.fieldcontrols.com 11/05/2019 © Field Controls,LLC P/N 0100-00 RevR 1% BUILDING DEPARTMENT