HomeMy WebLinkAboutFile Documents.434 E Main St.0177.2019 (2).ARBK STARFIRETM 35 DIRECT VENT GAS FIREPLACE NAPOLEON
Specifications
Model BTU Width Height Depth I Glass
Actual Framing Actual Framing Actual Framing
HDX35 35,000 43 3/8 43 7/8 42 3/4 43 20 1/8 19 7/8-20 1/2 31 1/8 x 28 5/32
Front Options
Classic Front Decorative Front
11 1/2'
r
33 7/8 1 3 77.5
0 0 0 0
- o r l I —o
31 7/16" 31 7/16'
L 0 gso—o,
Minimum Framing Clearances Minimum Framing Clearances
4
101II
70"
(1778mm) `I
Maintain these minimum clearances to combustibles from appliance and vent surfaces:Appliance framing: MINIUM Use steel framin rovided9 P
Non-Combustible Appliance finishing: Ceiling height
Front- 43/4"(121mm)to sides of appliance opening is minimum 24"- 10"(254mm)above appliance opening (610mm)from the
Combustible Appliance finishing: top of the appliance
- 70"(1778mm)from bottom of appliance to enclosure top opening.
- 2"(51mm)to top of vent pipe' "
- 1"(25mm)to sides and bottom of vent pipe' (1098mrn)
`HORIZONTAL VENT SECTIONS:A minimum clearance of 2"(51mm)to the top and 1"(25mm)to the sides and ``
bottom of the vent pipe on all horizontal runs to combustibles is required.
111
'VERTICAL VENT SECTIONS:A minimum of 1"(25mm)all around the vent pipe on all vertical runs to
ombustibles is required except for clearances in appliance enclosures.Use firestop spacer W500-0096(not
.applied). `
437/8" \
(1114mm) \
\
SZ
1,1
mml.
6 — . 6 619
24 Napoleon Road,Barrie,Ontario,Canada L4M 0G8•214 Bayview Drive,Barrie,Ontario,Canada L4N 4Y8
Fireplaces,Heating and Cooling:705-721-1212•Grills:705 726-4278•napoleonproducts.com ASPEN
BUILDING DEPARTMENT
STARFIRETM 35 DIRECT VENT GAS FIREPLACE NAPOLEON
Product information provided is not complete and is subject to change without notice. Please consult the installation manual for
the most up to date installation information.
Dimensions
--.— 201XS'[612mm]
lr
1
1=fillip.....•••E
4our
[1019mm]
[977mm]
11
SAFETY BARRIER iid [ ] �`
..
4 3.34' I -] /--\
[ ] 1�J
0 0 [IO2mn]� [1g&�]
1 OME 1
I - 43Yr[1101nm] [---•— 3 `'[turn"]—..--I I' 34416'[871mm] _I [Slam]
Wall Penetration
NOTE JOINT COMPOUNDS AND TAPES
THAT ARE RESILIENT TO HEAT AND 0
CRACKING SHOULD BE USED WHEN COMBUSTIBLEBRICK 0
TAPING AND MUDDING SEAMS. TOP OF ENCLOSURE O
_� _ /MATERIAL / — r
2'[Slmm] � [stem]
6'IF NONCOMBUSTIBLE
O FINISHING MATERIAL
INSULATED • O'COmm)IF NON- ►_ I O, IS USED SUCH AS
SLEEVE COMBUSTIBLE FINISHING - _� BRICK AND STONd�.xa,t6exe nrotr
� SUSEDSUCHASBRIIX. s SFRAMITUD I1d!1!uh1
Ml
7T
MINIMUM STEEL STUD NONCCA6USUBE IIL
10" FRAMING ="� MATERIAL 1 „rm]
MINIMUm] \ =[ 1 ]MINIMUM 25mm 4$ENCLOSURE •
B44tmm]GENE :I :f!!r 0 ASSEMBLY
I
HEIGHT ——— • •• 1332mm] 0
/ ; I• = MINIMUM [ gym] O
TOP OF I '[I PLUS RISE' ENC Dsu 5 = 527/16
HOW 423/4'
FIREPLACE ] • [I°eNm�] [1A NN M
OPENING 323/4' SAFETY BARRIER — - 323/4•
O O PLUMP
[832mm] K . [aw""]
MINIMUM I
o
1 p I ..
Do CI
NON COMBUSTIBLE I r
MATERIAL
k [2smm]
Combustible Mantel Clearances Appliance Location
I INSIDE CHASE OUTSIDE CHASE
22
p■t■■■■■■■ , . -_
■■■■■■■■■ - / 0 "1 / 0
M H 18 Ell....... �.:;
AE 16■■■■■■■■. ,_ Q6rt
TG 12■■■■ing■■n i= • • _L' • • :J
E H 10■■PCii■■■■■ ., ,,,,.IIIIMMEMENE
(") 6■■■■■■■■■ 1�•c
O■.....■.. D D I CORNER CHASE
1 2 3 4 5 6 7 A 9 1111 •
MANTEL DEPTH(") TOP OF
OPENING
ILI \
Re4 HeIgM Depth A O
A 323/4"(832mm) 7 ' O
B 8"(203mm) 2"(51mm)
C 10'(25481m) 4.(102mm)
D 12"(305mm) 6'(152mm) arlm`4• \TRECEIVED
E 14.(356mm) 8.(203mm) 1 - ertlT.i
OTA110/2019
24 Napoleon Road,Barrie,Ontario,Canada L4M 0G8•214 Bayview Drive,Barrie,Ontario,Canada L4N 4Y8
Fireplaces,Heating and Cooling:705-721-1212•Grills:705 726-4278•napoleonproducts.com ASPEN
BUILDING DEPARTMENT