Loading...
HomeMy WebLinkAboutFile Documents.434 E Main St.0177.2019 (2).ARBK STARFIRETM 35 DIRECT VENT GAS FIREPLACE NAPOLEON Specifications Model BTU Width Height Depth I Glass Actual Framing Actual Framing Actual Framing HDX35 35,000 43 3/8 43 7/8 42 3/4 43 20 1/8 19 7/8-20 1/2 31 1/8 x 28 5/32 Front Options Classic Front Decorative Front 11 1/2' r 33 7/8 1 3 77.5 0 0 0 0 - o r l I —o 31 7/16" 31 7/16' L 0 gso—o, Minimum Framing Clearances Minimum Framing Clearances 4 101II 70" (1778mm) `I Maintain these minimum clearances to combustibles from appliance and vent surfaces:Appliance framing: MINIUM Use steel framin rovided9 P Non-Combustible Appliance finishing: Ceiling height Front- 43/4"(121mm)to sides of appliance opening is minimum 24"- 10"(254mm)above appliance opening (610mm)from the Combustible Appliance finishing: top of the appliance - 70"(1778mm)from bottom of appliance to enclosure top opening. - 2"(51mm)to top of vent pipe' " - 1"(25mm)to sides and bottom of vent pipe' (1098mrn) `HORIZONTAL VENT SECTIONS:A minimum clearance of 2"(51mm)to the top and 1"(25mm)to the sides and `` bottom of the vent pipe on all horizontal runs to combustibles is required. 111 'VERTICAL VENT SECTIONS:A minimum of 1"(25mm)all around the vent pipe on all vertical runs to ombustibles is required except for clearances in appliance enclosures.Use firestop spacer W500-0096(not .applied). ` 437/8" \ (1114mm) \ \ SZ 1,1 mml. 6 — . 6 619 24 Napoleon Road,Barrie,Ontario,Canada L4M 0G8•214 Bayview Drive,Barrie,Ontario,Canada L4N 4Y8 Fireplaces,Heating and Cooling:705-721-1212•Grills:705 726-4278•napoleonproducts.com ASPEN BUILDING DEPARTMENT STARFIRETM 35 DIRECT VENT GAS FIREPLACE NAPOLEON Product information provided is not complete and is subject to change without notice. Please consult the installation manual for the most up to date installation information. Dimensions --.— 201XS'[612mm] lr 1 1=fillip.....•••E 4our [1019mm] [977mm] 11 SAFETY BARRIER iid [ ] �` .. 4 3.34' I -] /--\ [ ] 1�J 0 0 [IO2mn]� [1g&�] 1 OME 1 I - 43Yr[1101nm] [---•— 3 `'[turn"]—..--I I' 34416'[871mm] _I [Slam] Wall Penetration NOTE JOINT COMPOUNDS AND TAPES THAT ARE RESILIENT TO HEAT AND 0 CRACKING SHOULD BE USED WHEN COMBUSTIBLEBRICK 0 TAPING AND MUDDING SEAMS. TOP OF ENCLOSURE O _� _ /MATERIAL / — r 2'[Slmm] � [stem] 6'IF NONCOMBUSTIBLE O FINISHING MATERIAL INSULATED • O'COmm)IF NON- ►_ I O, IS USED SUCH AS SLEEVE COMBUSTIBLE FINISHING - _� BRICK AND STONd�.xa,t6exe nrotr � SUSEDSUCHASBRIIX. s SFRAMITUD I1d!1!uh1 Ml 7T MINIMUM STEEL STUD NONCCA6USUBE IIL 10" FRAMING ="� MATERIAL 1 „rm] MINIMUm] \ =[ 1 ]MINIMUM 25mm 4$ENCLOSURE • B44tmm]GENE :I :f!!r 0 ASSEMBLY I HEIGHT ——— • •• 1332mm] 0 / ; I• = MINIMUM [ gym] O TOP OF I '[I PLUS RISE' ENC Dsu 5 = 527/16 HOW 423/4' FIREPLACE ] • [I°eNm�] [1A NN M OPENING 323/4' SAFETY BARRIER — - 323/4• O O PLUMP [832mm] K . [aw""] MINIMUM I o 1 p I .. Do CI NON COMBUSTIBLE I r MATERIAL k [2smm] Combustible Mantel Clearances Appliance Location I INSIDE CHASE OUTSIDE CHASE 22 p■t■■■■■■■ , . -_ ■■■■■■■■■ - / 0 "1 / 0 M H 18 Ell....... �.:; AE 16■■■■■■■■. ,_ Q6rt TG 12■■■■ing■■n i= • • _L' • • :J E H 10■■PCii■■■■■ ., ,,,,.IIIIMMEMENE (") 6■■■■■■■■■ 1�•c O■.....■.. D D I CORNER CHASE 1 2 3 4 5 6 7 A 9 1111 • MANTEL DEPTH(") TOP OF OPENING ILI \ Re4 HeIgM Depth A O A 323/4"(832mm) 7 ' O B 8"(203mm) 2"(51mm) C 10'(25481m) 4.(102mm) D 12"(305mm) 6'(152mm) arlm`4• \TRECEIVED E 14.(356mm) 8.(203mm) 1 - ertlT.i OTA110/2019 24 Napoleon Road,Barrie,Ontario,Canada L4M 0G8•214 Bayview Drive,Barrie,Ontario,Canada L4N 4Y8 Fireplaces,Heating and Cooling:705-721-1212•Grills:705 726-4278•napoleonproducts.com ASPEN BUILDING DEPARTMENT