HomeMy WebLinkAboutFile Documents.395 Thunderbowl Ln.0255.2018 (32).ARBK 0 REScheck Software Version 4.6.5
Compliance Certificate
Project Thunderbowl Residence i
06/28/2019 1j
Energy Code: 2015 IECC FCRCOI.ttUowiwll7E
Location: Aspen, Colorado bonniem
Construction Type: Single-family
Project Type: New Construction
Conditioned Floor Area: 9,700 ft2
Glazing Area 27%
Climate Zone: 7 (9922 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
Lot 7 Thunderbowl Roger Hall Nathan Radomski
Aspen,CO 81611 David Johnston Architects Architectural Engineering
119 South Spring St Consultants
Suite 203 40801 US-6
Aspen,CO 81611 #214
970-925-3444 Avon, CO 81620
roger@djarchitects.com 970-748-8520
nathan@aec-vail.com
Compliance: Passes using UA trade-off
Compliance: 16.8%Better Than Code Maximum UA: 1426 Your UA: 1187
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
R-60 is max input
Envelope Assemblies allowed by REScheck
Gross Area Canrity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Ceiling R-1, R-2, R-3,or R-4: Steel Joist/Rafter, 16"o.c.:2x4 4,268 60.0 0.0 0.017 73
Ceiling F-5: Steel Joist/Rafter, 16" o.c.:2x4 440 49.0 5.0 0.019 8
Basement Wall (W-5): Solid Concrete or Masonry 5,131 0.0 15.0 0.038 195
Wall height: 12.0'
Depth below grade: 12.0'
Insulation depth: 12.0'
North Wall (W-1,W-2, or W-4):Wood Frame, 16" o.c. 1,959 29.0 5.0 0,037 36
Grabill Direct Set: Metal Frame with Thermal Break:Triple Pane with Low-E 247 0.230 57
Grabill Casement: Metal Frame:Triple Pane with Low-E 39 0.260 10
Grabill Awning: Metal Frame:Triple Pane with Low-E 49 0,260 13
2.01a Operable Arcadia: Metal Frame:Double Pane with Low-E 116 0.310 36
2.02a Fixed Arcadia: Metal Frame:Double Pane with Low-E 115 0.330 38
2.01b Fixed Arcadia: Metal Frame:Double Pane with Low-E 93 0.360 33
2.01c Operable Arcadia: Metal Frame:Double Pane with Low-E 29 0.380 11
2.01d Operable Arcadia: Metal Frame:Double Pane with Low-E 18 2.02b Operable Arcadia: Metal Frame:Double Pane with Low-E 28 RED
.4 13
Project Title:Thunderbowl Residence Report dQtI13r71 540-9
Data filename: Z:\Shared\Projects\Current Projects\17032.00 - Lot 7 Thunderbowl Page 11Cof 2
Residence\Calculations\Energy Calcs\17032 Thunderbowl.rck ASP
BUILDING DEPARTMENT
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Grabill Sliding door: Glass 120 0.270 32
Grabill Swing door: Glass 120 0.290 35
East Wall (W-1,W-2,or W-4):Wood Frame, 16" o.c. 2,180 29.0 5.0 0.037 61
Grabill Direct Set: Metal Frame:Triple Pane with Low-E 137 0.230 32
Grabill Casement: Metal Frame:Triple Pane with Low-E 60 0.260 16
2.03a Fixed Arcadia: Metal Frame:Double Pane with Low-E 63 0.310 20
2.03b Fixed Arcadia: Metal Frame:Double Pane with Low-E 24 0.320 8
Garage door:Solid 242 0.320 77
South Wall (W-1,W-2, or W-4): Wood Frame, 16" o.c. 1,770 29.0 5.0 0,037 46
Grabill Direct Set: Metal Frame:Triple Pane with Low-E 211 0.230 49
Grabill Awning: Metal Frame:Triple Pane with Low-E 22 0.260 6
2.03a Fixed Arcadia: Metal Frame:Double Pane with Low-E 91 0.290 26
2.03b, 2.05a Fixed Arcadia: Metal Frame:Double Pane with Low-E 65 0.310 20
2.05b Operable Arcadia: Metal Frame:Double Pane with Low-E 81 0.330 27
2.05c Fixed Arcadia: Metal Frame:Double Pane with Low-E 10 0.390 4
2.05d Fixed Arcadia: Metal Frame:Double Pane with Low-E 5 0.420 2
2.05e Fixed Arcadia: Metal Frame:Double Pane with Low-E 19 0.410 8
Grabill Sliding door: Glass 21 0.290 6
South Wall (W-3 or W-6): Solid Concrete or Masonry:lnterior Insulation 358 24.0 5.0 0.044 16
West Wall (W-1, W-2,or W-4):Wood Frame, 16" o.c. 1,378 29.0 5.0 0.037 36
Grabill Direct Set: Metal Frame:Triple Pane with Low-E 249 0.230 57
Grabill Casement: Metal Frame:Triple Pane with Low-E 30 0.260 8
Grabill Awning: Metal Frame:Triple Pane with Low-E 32 0.260 8
2.06a Fixed Arcadia: Metal Frame:Double Pane with Low-E 29 0.360 10
2.06b Fixed Arcadia: Metal Frame:Double Pane with Low-E 19 0.370 7
Grabill Swinging door: Glass 54 0.290 16
West Wall (W-3 or W-6): Solid Concrete or Masonry:lnterior Insulation 521 24.0 5.0 0.044 23
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.5 and to comply with the mandatory requi en fisted i the REScheck Inspection Checklist.
f iwkW RA}OK54.1 - M660,1 c y Ci411140K- Z/r/!A
Name-Title Si ature Date
RECEIVED
Project Title: Thunderbowl Residence Report ddi /30$/tR 9
Data filename: Z:\Shared\Projects\Current Projects\17032.00 - Lot 7 Thunderbowl Page 2 of 2
Residence\Calculations\Energy Calcs\17032 Thunderbowl.rck ASPEN
BUILDING DEPARTMENT