Loading...
HomeMy WebLinkAboutSub Permit.610 S West End St.0068.2019.ARBK General Notes TMR Components 1. This drawing emphasizes the IMP pitched flashing VELUX SUN TUNNEL Skylight. It illustrates a general arrangement layout (plus recommendations) for a VELUX TMR installation in a 14-60 degree roof pitch application utilizing either a suspended acoustical tile or grid ceiling installation. 1142-60o I 2. The architectural/structural design and specifications for the inclusion of a tubular daylighting device, such as the VELUX IMP, in any roofing/ceiling application is determined TMR 014 0000/TMR 010 0000 and provided by others. The design criteria includes, but is not limited to design loads, structural configurations, structural framing member sizes and material , architectural • Acrylic Dome finishes and integration with the roofing/ceiling systems of the building. VELUX assumes no responsibility or liability in the design, construction and performance of a building • Counter flashing ii structure by others. assembly • Top collar (167.41m) 3. Dimensions shown are nominal, unless indicated otherwise. =010 13 �" . Hardware bag Outside 16 1. l e i 4. TMR 010 0000 nominal diameter is 10". TMR 014 0000 nominal diameter is 14". diameter 014 = 17 g" • Option 16 • p •TMR 014 1000/TMR 0101000 5. Maximum tunnel length is 20'. Minimum tunnel length is 16". 5/8>> dome shield Impact Polycarbonate dome 6. Ceiling rough opening cut for 010 = 10i", 014 = 14i". I — — _ • 24"/.61 m Rigid tunnel Dome 0.125" thick Injection molded • (2) 11.5"/.29m Rigid elbows 7. Minimum 1 1/4" clearance required around ceiling rough opening, to fit trim ring. • Tape for tunnel joints / Insulation — Provided by installer • Hardware bag A �, • Ceiling ring assembly Flashing — Galvanized sheet with crackle over frosted 010 = 6 1" V / \ steel 0.023" (24 GA) thickness. diffuser • / \ Gray powder coat finish • Gasket material 0 • 014 = 7" / for diffuser e Hardware bag B — U _ - B 4" reflective collar L _ I _ F� 1Options II 63/4" Diameter • ZTC 014 0002US—Prismatic diffuser Minimum I • ZTC 014 0003US Fresnel diffuser Reflective tunnel, 24" length I Option: ZTC 014/ZTC 010 0041US Energy kit �i provided in kit. Anodized aluminury� Pli MINN • Residential energy kit Atunnel is 0.016" (26 GA) thick \ 1 I / Two 11.5" tall universal (Heat shield & CD with 99% reflectance. \ I> / reflective elbows provided quad diffuser) Plan View \ in IMP kit. Each aluminum elbow rotates 45'. Option: ZTR 014/ZTR 010 Rigid Tunnel Extensions 010 = 243�4 >' / Thickness 0.02" (24 GA) p 9 Lb' 014 = 29" / / • ZTR 014/ZTR 010 0002 EL 0\0 -- -50"i2 / -- / 24"/.61m Rigid tunnel \ V Flexi—Loc clips (Typical) • ZTR 014/ZTR 010 0004 DT , N" 2 • 1 48"/1.22m Rigid tunnel / v f `v�1 \ Roof Framing ZTR 014/ZTR 010 mmm � 72"/1.83m Rigid tunnel r �� ^ _� • ZTR 014/ZTR 010 0012 m m m m Shingles _-�`" f� • 44"/3.66m Rigid tunnel g =.� ' �' �• �r I ZTR 28877.32m Z Rigid 010 00 tunnel mmmmmm �-- i / i VELUX tape \�/ / Rigid VELUtunnelVELUX TMR All joints must be sealed \ I / VELUX tape Mount & flash using with tape, provided by VELUX I standard roofing j practices for l / \ VELUX screw roofing material __i__ I I I ____ i / being used. Ceiling ring ABS material / White Insulation a -- VELUX tape attaching -- I 11111D11i (�1 i Bill ml �i 0 tional ZTC to vapor barrier ' �I!�1���11111! u1Q��6�: 111j--.' Dpal diffuser t pEnergy kit \Vapor barrier II I VELUX Finish material \ , , —IN' , , ,I � ) I „ , „ , ,,, Ceiling Diffuser Assembly ` )I I \ ' / -�-_; , Section A-A Section B- B V/par barrier General Arrangement Layout Crackle diffuser lens (Standard) / VELUX Frosted diffuser 8 VELUX 1418 Evans P° ECEIVED lens (Standard) See Neste 7 / Trim ring G ri soo as vE White acrylic www.VELUXUSA.com Sky-Global Product Management 10 ' 1 TMR - Residential SUN TUNNEL 03/29/20-9 This drawing is an instrument of service and is provided for informational use only. ASPEN © 2015 VELUX GROUP 0 VELUX is a registered tra�® DEPARTMENT