HomeMy WebLinkAboutFile Documents.183 Red Mountain Rd.0038.2018 (4).ARBK SWCARLISLE'S SURE-WELD® Kum Sure-Welds(TPO) Adhered Roofing Systems Code Approval Guide January,2017 Table of Contents Introduction ii Guidelines iii Sure-Weld Mechanically Fastened or Induction Welding Roofing Systems UL Approvals Non-Combustible-ANSI UL-Class A 4 Combustible-ANSI UL-Class A 5 Combustible-ANSI UL-Class B 6 Combustible and Non-Combustible-ANSI UL-Class C 7 Existing UL Rating Retained 7 FM Approvals FM Approval-Field Sheet Securement Criteria 8 FM Approval-Induction Welding Securement Criteria 9 90 psf Uplift Resistance Test 10 FM Class A Roof Deck 11 ANSI-SPRI 12 Sure-Weld Metal Retrofit Roofing Systems Metal Retrofit 13 Sure-Weld Adhered Roofing Systems UL Approvals Non-Combustible-ANSI UL-Class A 14 Combustible-ANSI UL-Class A 15 Combustible-ANSI UL-Class B 17 Combustible and Non-Combustible-ANSI UL-Class C 18 FM Approvals SecurShield HD New Construction 19 SecurShield HD Recover 21 SecurShield HD Plus New Construction 22 SecurShield HD Plus Recover 24 InsulBase Polyiso New Construction 25 InsulBase Polyiso Recover 27 SecurShield and SecurShield HD Composite New Construction 28 SecurShield Recover 30 Securock New Construction 31 Securock Recover 33 DensDeck Prime New Construction 34 DensDeck Prime Recover 36 OSB New Construction 37 OSB Recover 38 HP Recovery Board New Construction 39 HP Recovery Board Recover 41 Lightweight 42 National,State&City Building Code Approvals 43 Dade County(South Florida)Approvals 43 Reference Notes 44 RECEIVED 600163-SWCodes 1f,1 /2O18 ASPEN BUILDING DEPARTMENT CARLISLE SynTec A Division of Carlisle Construction Materials,Incorporated CODE APPROVAL GUIDE January,2017 INTRODUCTION This Code Approval Guide addresses both general information pertaining to Underwriters Laboratories(UL)and FM Approvals(FM)test criteria as well as specific UL and FM code approvals achieved with Carlisle's Sure-WeldTMAdhered and Mechanically-Fastened Roofmg Systems. Various independent test laboratory results along with national building code approvals are also identified in this guide. Code approvals available with Carlisle's FleeceBackTM,Hot Mopped,Sure Flex and Sure-Seal®Roofing Systems are identified in separately published Code Approval Guides. Code ratings are categorized by roof system type(Mechanically-Fastened Adhered)and are separated into two sections:UL Approvals and FM Approvals.UL rated roof assemblies are grouped according to deck type(non-combustible or combustible)and are further categorized according to deck type and the specific type of construction(new,recover,tear-off or retrofit). The listed assemblies contained in the guide are grouped generically based on deck classification. Specific substrate requirements for each Carlisle roofing system can be identified in the respective Carlisle specifications. In the UL and FM Approvals throughout this guide,when multiple layers of insulation are referenced,the product listed first identifies the insulation directly below the membrane. For example;a listing of HP Recovery Board/Polyisocyanurate indicates the HP Recovery Board is installed directly under the membrane. A listing of Gypsum Board/Polystyrene indicates the Gypsum Board is installed directly under the membrane. <<TABLE OF CONTENTS RECEIVED 600163-SW Codes 1 Q{/2Q11/2 018 ASPEN BUILDING DEPARTMENT GENERAL GUIDELINES FOR UL AND FM APPROVALS CODE COMPLIANCE No table of figures entries found. Approvals(FM)approved assembly is specified. Generally,the Carlisle published specifications reflect the minimum requirements necessary to obtain the applicable Carlisle warranty. Code requirements are not specifically covered in the Carlisle specifications and are considered to be above and beyond the provisions of the Carlisle warranty. Individuals specifying an approved assembly or selecting various products to achieve a specific UL/FM rating must recognize the importance of ensuring proper component selection to fully comply with the most current listings published. All materials used in the roofing systems must be UL and/or FM approved and must have been tested together as part of a complete roof assembly. In addition to the code approval listings in this guide,information pertaining to approved assemblies can also be obtained directly from UL and FM as follows: 1. Underwriters Laboratories On-Line Certification Directory(uLcom) 2. FM Approvals RoofNay website(roofnay.com). FM RoofNav assembly numbers can be obtained from this website. UL,FM Approvals and ASNI/SPRI WD-1 Clarifications/Enhancements Underwriters Laboratories 1. The criteria required to obtain UL External fire ratings(Class A,B or C)can be identified in this guide or can be searched for on the UL website using the UL Category Code TGFU.UL ratings approved for use on combustible decks are also acceptable on non-combustible decks. 2. For UL internal fire ratings(hourly constructions—P Numbers),search the UL website use the UL Category Code BXUV. FM Approvals Uplift ratings listed in this guide are for the field of the roof. Additional requirements/enhancements are required by FM in the perimeter and corner areas,for deck securement and for perimeter nailer/edge attachment. Refer to FM Property Loss Prevention Data Sheets 1-28,1-29 and 1-49 for specific requirements. On FM insured projects,the FM insuring agent MUST review and approve the proposed roofing assembly prior to installation. When FM is not the insuring entity for the building,use the Approved American National Standard ANSUSPRI WD-1 for design purposes. Note:All Carlisle roof systems referenced within this document meet Class 1 construction and Severe Hail(SH)rating. Approved American National Standard ANSI/SPRI WD-1 The ANSI/SPRI Wind Design Standard Practice for Roofing Assemblies should be referenced when a project is not FM insured.This document was developed as a consensus National Standard and provides a methodology for designing for wind uplift resistance of roofing system assemblies. Insulation fastening patterns are included in this document. The fastening patters are approved for use by Carlisle. RECOVERS Recover approvals in this document are based on the following existing roofing system assumption- the existing Smooth Asphalt BUR,Modified Bitumen or single-ply system was FM Approved at the time of installation. SUMMARY Due to complexity of the code documents and the variety of information that must be reviewed,it is important to consult with Carlisle and other respective manufactures concerning the most current available approvals. • Prior to project bid—Products specified by the architect must be thoroughly investigated to determine if the specified rating can be achieved and local building codes must be consulted regarding any additional requirements. • Prior to installation—Project managers should review the code requirements with field construction personnel to ensure compliance with project requirements. Upon completion of the roofing installation,each project is inspected by a Carlisle Technical Representative to ensure compliance with Carlisle's current specification requirements for the issuance of the applicable warranty.However,this inspection is not for the purpose of verifying code compliance. «TABLE OF CONTENTS RECEIVED 600163-SW Codes iii /2 1 1 1/2018 ASPEN BUILDING DEPARTMENT Sure-Welds(TPO)Mechanically-Fastened or Induction Welding Roofmg Systems UL Approval-Non-Combustible-ANSI/UL 790 Spread of Flame Test(Class A) .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) Membrane .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Non-Combustible:Steel;St.Concrete;Gypsum;Tectum(Min.2"thick) System ID Deck Type Inwlstlon Corer Baird Sue-Weld,SUFeW• EXTRA or - L Weld InsulBase,SecurShield,SecurShield HD,SecurShield HD Plus or I N/A SecurShield HD Composite-any combination,any thickness Minimum 1/2"SecurShield 2 Any UL Classified EPS or XPS Insulation,any thickness HD,SecurShield HD Plus or 1 2 1: SecurShield HD Composite Minimum 1"layer of InsulBase,SecurShield,or SecurShield HD 3 Composite over any UL Classified EPS or XPS Insulation,maximum N/A 1.25 pcf,any thickness 4 Insulfoam SP or Insulfoam SP over Insulfoam EPS,any thickness N/A I„ 1' and density. 5 Insulfoam HD Composite or Insulfoam HD Composite over N/A 1/2" Insulfoam EPS,any thickness and density. Non-Combustible Minimum 1/4"SECUROCK® 6 Any UL Classified Insulation,any thickness(OPTIONAL) 3" 3' Gypsum-Fiber Board 7 Any UL Classified Insulation,any thickness(OPTIONAL) M1O1mum 1/4"SECUROCK® 3• Unlimited Glass Mat Board Minimum 1/4" 3"Sure-Weld 8 My UL Classified Insulation,any thickness(OPTIONAL) DensDeck/DensDeck Prime 2-1/2"Sure-Weld EXTRA Unlimited Roof Boards Any UL Classified Insulation,any thickness(OPTIONAL) Minimum Boar "HP Recovery 1-1/2' 1-1/2" Minimum 7/16"APA Rated 11, Any UL Classified Insulation,any thickness(OPTIONAL) OSB 1-1 I 1 i 2 or Minimum 1-1/2"StormBase 11 Any UL Classified Insulation,any combination,any thickness Carlisle FR Base Sheet I" 12 Cellular Lightweight N/A N/A 1-1/2" Concrete 3 Structural(poured-in- 1 N/A N/A 1-I/2" place)concrete «TABLE OF CONTENTS RECEIVED 6011163 SWCodcs Page 4of44 1 /211/2018 ASPEN BUILDING DEPARTMENT Sure-Weld®(TPO)Mechanically-Fastened or Induction Welding Roofing Systems UL Approval-Combustible-ANSI/UL 790 Spread of Flame Test(Class A) .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) Membrane .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Combustible:7/16-in.(minimum)thick non-veneer APA-rated sheathing(oriented strand board panels,structural particleboard panels,composite panels or waferboard panels);15/32-in. (minimum)thick plywood 3/4 in.(minimum)wood;Tectum(less than 2"thick) Maximum Slope r:em ID Thermal Barrier/Base Sh ; elation Cover Board Sure-Weld,Sure- Weld EXTRA or Sure-Weld Snectro-Weld Combustible-ANSI/UL 790 Spread of Flame Test-Class A Minimum 1/4"SECUROCK Any UL Classified Carlisle Polyisocyanurate Insulation,any I Gypsum Fiber or Glass Mat Roof N/A 1/2" 1/2" Boards(1) combination,any thickness. Minimum 1/4"DensDeck/DensDeck Any UL Classified Carlisle Polyisocyanurate Insulation,any 2 N/A 1/2" 1/2 Prime Roof Boards(1) combination,any thickness. Minimum 3"layer or two layers of 1-1/2"SecurShield or 3 N/A N/A 1/2" 1!2" SecurShield HD Composite.(1)(3) Minimum 2-1/2"layer SecurShield or SecurShield HD 4 N/A Composite over a 2-1/2"(minimum)layer of Carlisle N/A 1/2" 1/2" InsulBase Insulation.(1)(4) 5 Carlisle FR Base Sheet Minimum 1.9"layer of SecurShield or SecurShield HD N/A 1/2" 1!2" Composite.(1)(4) G N/AMin mum 2-1/2"layer of any UL Classified Carlisle Minimum 1/2"SecurShield HI) 1/2" 1/2" Polyisocyanurate Insulation,any combination.(1) or SecurShield HD Plus 7 Carlisle FR Base Sheet Minimum 1.4"layer of any UL Classified Carlisle Minimum 1/2"SecurShield HD 1/2" I/2" Polyisocyanurate Insulation,any combination.(1) or SecurShield HI)Plus S3 N/A Minimum 1"layer of SecurShield CD. (1)(5) N/A 1/2" 1/2" 9 N/A Minimum 4"layer of any UL Classified EPS Insulation. Minimum 1/2"SecurShield HD 1/2" 1/2" (l)(6) or SecurShield HD Plus Minimum 1"layer of SecurShield CD over a minimum 3-1/2" 10 N/A N/A 1/2" 1!2" layer of any UL Classified EPS Insulation.(1)(6) • I Minimum 1-1/2"layer of Insulfoam HD Composite over a I I N/A N/A 1/2" 1/2" minimum 3"layer of Insulfoam EPS.(1)(6) I N/A Minimum 2"layer of Insulfoam HD Composite over a N/A 1/2" 1 i2" minimum 2-1/2"layer of Insulfoam EPS. (1)(6) 13 N/A Any UL Classified Carlisle Polyisocyanurate Insulation,any Minimum 1/4"SECUROCKR 3" combination,any thickness. Gypsum Fiber Roof Board(1) 14 Any UL Classified Insulation,any thickness(OPTIONAL) Minimum 3/8"SECUROCK® Gypsum Fiber Roof Board(I) 15 N/A Any UL Classified Insulation,any thickness(OPTIONAL) Minimum 1/2"SECUROCK® Gypsum Fiber Roof Board(1) 16 One Ply of Type G2 Any UL Classified Insulation,any thickness(OPTIONAL) M1°rmum 1/4"SECUROCK® 3" 3" Gypsum Fiber Roof Board(I) Minimum 1/4"SECUROCK® 3"-Sure-Weld 17 N/A Any UL Classified Insulation,any thickness(OPTIONAL) Glass Mat Roof Board(1) 2-1/2"-Sure-Weld Unlimited EXTRA Minimum 1/4"Dens 3"-Sure-Weld I s N/A Any UL Classified Insulation,any thickness(OPTIONAL) Deck/DensDeck Prime Roof 2-1/2"-Sure-Weld Unlimited Boards(1) EXTRA Two layers of Carlisle FR Base Any UL Classified Carlisle Polyisocyanurate Insulation,any 19 N/A 1/2" 1/2" Sheet combination,any thickness. «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 5 of 44 1 Ll2�11/2 0 18 ASPEN BUILDING DEPARTMENT Sure-Weld'(TPO)Mechanically-Fastened or Induction Welding Roofing Systems UL Approval-Combustible-ANSI/UL 790 Spread of Flame Test(Class B) .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) Membrane .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) Tom' .060"or.080"Spectra-Weld Reinforced Membrane(White) Combustible:7/16-in.(minimum)thick non-veneer APA-rated sheathing(oriented strand board panels,structural particleboard panels,composite panels or waferboard panels);15/32-in. (minimum)thick plywood 3/4 in.(minimum)wood;Tectum(less than 2"thick) Maxir umSlope System ID Thermal BarrierBase Sheet Cover Board(2) Sure-Weld,Sure-Weld EXTRA or Spetro-Weld Sure-Weld Combustible-ANSI/UL 790 Spread of Flame Test-Class B 1 N/A Minimum 1.9"layer of SecurShield or SecurShield 11ll , Composite.(7)(8) Minimum 1.4"layer of any UL Classified Carlisle Minimum 1/2" 2 N/A SecurShield HD or Polyisocyanurate Insulation.(7) SecurShield HD Plus 3 N/A Minimum I"layer of SecurShield CD.(7)(9) N/A 1/2" 1/2' One Layer of Carlisle FR Any UL Classified Carlisle Polyisocyanurate Insulation,any N/A 1/2" I/2" Base Sheet combination,any thickness.(OPTIONAL) Inverted G3 cap sheet N/A N/A 1/2" 1/2" «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 6 of 44z / O S 8 ASPEN BUILDING DEPARTMENT Sure-Weld®(TPO)Mechanically-Fastened or Induction Welding Roofing Systems UL Approval-Combustible and Non-Combustible-ANSI/UL 790 Spread of Flame Test(Class C) .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) Membrane .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) Tom' .060"or.080"Spectro-Weld Reinforced Membrane(White) Combustible:7/16-in.(minimum)thick non-veneer APA-rated sheathing(oriented strand board panels,structural particleboard panels,composite panels or waferboard panels);15/32-in. (minimum)thick plywood 3/4 in.(minimum)wood;Tectum(less than 2"thick) Non-Combustible:Steel,St.Concrete,Gypsum or Tectum(Min.2"thick) 4111!; Madr®Slope _ System ID Thermal Barrier/Base Sheet ver Board Sure-Weld,Sure-Weld EXTRA or Spectro-Weld Sure-Weld:c Combustible-ANSI/UL 790 Spread of Flame Test-Class C N/A Any combination,any thickness of UL N/A Unlimited Unlimited Classified Carlisle Polyisocranuratc lsulation Non-Combustible-ANSI/UL 790 Spread of Flame Test-Class C N/A Any combination,any thickness of UL K A Unlimited Unlimited Classified Carlisle Polyisocyanurate Insulation. Existing UL Rating Retained Non-Combustible or Combustible (Directly over existing Class A,B or C) Maximum Slope Deck Existing Substrate Insulation Sure-Weld,Sure-Weld EXTRA or Spectro-Weld Sure-Weld IiS 1 N/A Direct application over Smooth Asphalt BUR(Type N/A 1/2" 1/2" III or IV Asphalt) 2 N/A Direct application over Mineral Surfaced Cap Sheet N/A 1/2" 1/2" 3 N/A Direct application over Modified Bitumen N/A 1/2" 1/2' • 4 N/A Direct application over approved single-ply N/A I/2" 1/2' • Carlisle FR Base Sheet IS over existing min.UL Class"C"rated Type III or IV Smooth Asphalt BUR, 5 N/A Base Sheet 1/2" 3/4' Mineral Cap Sheet,Modified Bitumen or approved single-ply to remain Existing minimum Class C smooth or gravel surface 6 N/A (gravel maintained)DUR,mineral cap sheet or Max.1"Insulfoam 1/2" 1/2„ Modified Bitumen R-Tech or SP «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 7 of 44 /2 0 18 ASPEN BUILDING DEPARTMENT Sure-Weld°(TPO)Mechanically-Fastened or Induction Welding Roofing Systems FM Approvals and Equivalencies FM Approval-Field Sheet Securement Criteria (Please see notes 10,11,12 and 15) .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) Membrane .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Type; .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Min.22 Gauge Min•22 Gauge Min.18 Gauge Grade C Steel(33 ksi) Grade E Steel(80 ksi)(13)or Struc Steel embrane Concrete dth(11) Fastener/Ilate(12L Sure-Weld,Sure-W Sure-Weld,Sure- EXTRA or Spectro- eld EXTRA or Sure-Weld HS Sure-Weld or Sure-Weld Weld tro-Weld EXTRA ji 1-165 1-165 6' 136102-0-0 136102-0-0 4 Feet(14) HP-X/P ranha 1-105 1-'' - 136101-0-0 1-90 6 Feet HP-X/Piranha 12' - 392183-0-0 1-75 1-135 1-120 6" 350392-0-0 12496-0-0 106202-0-0 HP-X:Piranha 1-75 1-90 12" 1-75 8 Feet 392184-0-0 12562-0-0 142983-0-0 HP-Xtra/Piranha Xtra 12" 1-75 1-75 1-90 1-75 350394-0-0 142996-0-0 143000-0-0 142996-0-0 1-90 6" - - - - 107469-0-0 1-IP-X:Piranha 1-75 1-75 1-90 12" 10 Feet 107470-0-0 106205-0-0 12807-0-0 6 - _ - HP-Xtra/Piranha Xtra 1-90 12788-0-0 1-105 1-75 1-120 6 140986-0-0 106197-0-0 141042-0-0 HP-X/Piranha 1.60 1-60 1-60 12" 140548-0-0 106201-0-0 140548-0-0 12 Feet 6., 1-120 1-120 141023-0-0 - 141023-0-0 HP-Xtra/Piranha Xtra (RoofNAV Number)-directly over Min.15"of Insulllase Polyiso or SecurShield «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 8 of 44 / O 18 ASPEN BUILDING DEPARTMENT FM Approvals—Induction Welding Grid Securement .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) "111111111111141cMPIT- HP-X/induction Plate 1-90 RhinoBond and IsoWeld RB 222555-0-0 10 I e IW 378853-0-0 8 Min.22 gauge IIP-X/RhinoBond 1-105(RhinoBond Only) 222553-0-0 16 20 Grade C Steel Deck 10 HP-X/lsoWeld 1-150(IsoWeld Only) 20 25 378890-0-016 HP-X/RhinoBond 1-165(RhinoBond Only) 28 40 386367-0-08 HP-X/RhinoBond 1-120(RhinoBond Only) 16 20 222375-0-0 Min.22 gauge Grade E Steel Deck 16 HP-X/RhinoBond 1-195(RhinoBond Only) 28 40 387161-0-0 1-90 RhinoBond 6 10 16 8 1-105(RhinoBond Only) 16 20 311967-0-0 Concrete HD 14-1/RhinoBond 1-120(RhinoBond Only) 16 20 312569-0-016 1-195(RhinoBond Only) 28 40 386369-0-0 FM Approvals-Induction Welding Linear Securement Deck Type 11221.1k 12" 1-75 323353-0-0 Min.22 gauge _1I' RhinoBond 5' 6" 1-135 Grade E Steel Deck 323355-0-0 10' 6" 1-75 323398-0-0 (RoofNAV Number)over InsulBase Poly'so «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 9 of 44 1 Q{/2Q1i/2 O 1 8 ASPEN BUILDING DEPARTMENT 90 psf Uplift Resistance Test(1-90 Equivalency on 12'x 24'Table) Wind uplift testing has been completed in accordance with the FM 4470 Test Procedure which is witnessed and certified by Architectural Testing, Incorporated,an industry recognized Independent Testing Laboratory.Over a 22 gauge Grade E Steel roof deck,the following results were obtained using HP-X Fasteners and Piranha Plates for membrane securement.The Performance Test Report is on file and available from Carlisle. Membrane Type: .045"or.060"Sure-Weld Standard Reinforced Membrane(white,gray or tan). • Type Field Membrane Width Fastener S . tine Type and Thi ' Insulation Fastening 10' Min.22 gauge See notes 16 and 17. 12" Per Carlisle Specification Per Carlisle Specification «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 10 of 44 / O 18 ASPEN BUILDING DEPARTMENT Sure-Weld®(TPO)Mechanically-Fastened or Induction Welding Roofing Systems FM Class A Roof Deck Construction and Insulation Approvals(18) .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectre-Weld Reinforced Membrane(White) Maximum Slope for ASTM E-108 Class"A"Rating Insulation(19) Insulation Thickness Sure-Weld,Sure-Weld EXTRA or Spectro-Weld Carlisle HP Recovery Board 1/2"Min. 1-1/2"(with Recovery Board or Securock overlay) 2"(with Recovery Board or Securock Carlisle HP Recovery Board(min.1/2"), 5" overlay) DensDeck(min.1/4")or Securock(run.1/4") (with DensDeck overlay and New Construction/Tearoff: Over: Refer to FM RoofNav website Sure-Weld Standard) 5" Steel(Minimum 22 gauge) FM Approved Insulation(20) (with DcnsDeck overlay) Structural Concrete 3"(with DensDeck overlay and Sure-Weld EXTRA) Retrofit(No Tearoff)(21): Structural Concrete Carlisle Polyisocyanurate InsulBase or 1-1/2"-12" SecurShield Carlisle SecurShield HD or SecurShield HD Plus I (_ Over: 1/2"/Refer to FM RoofNAV website FM Approved Insulation(20) Carlisle HP Recovery Board 1/2"-1" 1-1/2" Retrofit(No Tearoff)(21): Carlisle Polyisocyanurate InsulBase or Steel(Minimum 22 gauge) I"Max. SecurShield I-I Carlisle SecurShield HD or SecurShield HD Plus 1/2" «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 11 of 44 1 Q{/2Q17s /2018 ASPEN BUILDING DEPARTMENT Sure-Weld®(TPO)Mechanically Fastened or Induction Welding Roofmg Systems ANSI-SPRI WD-1/ASCE 7-10 Approvals .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) Membrane .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Type: -080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Min.22 Min.22 Gauge Grade C.S e E Steel(80 ksi)or S ' .18 Gauge Membrane Concrete Steel W, Fastener/P F eld,Sure-Weld Wd,Sure-Weld Sure-Weld,Sure- or Spectra- Sure-W EXTRAA or Spectro- Sure-Weld HS Weld EXTRAEXTRA or Sure-Weld or Sure- Weld Weld Spettro-Weld Weld EXTRA r, 1-165 1-165 - 4 Feet HP-X/Piranha 12" 1-105 - 1-105 - 6 Feet HPX/Piranha I T' 1-90 - - - - 6- 1-105 - 1-135 1-120 1-90 HP-X/Piranha 8 Feet 12" 1-75 1-60 1-90 1-75 1-75 IiPXvarl'iranhaXrra 12" 1-90 1-75 1-90 1-75 - 6" 1-105 1-90 1-120 1-75 HP-X/Piranha 9" 1-75 1-60 1-90 1-90 lO Feet 12" 1-60 1-75 1-75 190 6" 1-120 1-120 HP-Xtra!Piranha Xtra 12" 1-60 1-90* 6" 1-105 1-120 1-75 I1P-X!Piranha 9" 1-75 I)i 1-75 - 12" 1-60 1-60 1-60 12 Feet 6" 1-120 1-120 - IiP-Xtra,Piranha Xtra 9" 1-75 1-75 12" 1-60 - 1 60 *Max 1-75 using Spectro-Weld «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 12 of 44 1 /2Q11 /2 018 ASPEN BUILDING DEPARTMENT Sure-Weld°Metal Retrofit Roofing System Underwriters Laboratories(UL)Approvals The UL ratings achieved with the Metal Retrofit Roofing System are identical to the approvals listed for the Sure-Weldre"Mechanically-Fastened Roofmg System over non- combustible decks depending on the membrane selected.Click here for ratings. FM Approvals As referenced in FM Approvals Loss Prevention Data Sheet 1-31,the method of recovering an existing metal roof system with a single-ply mechanically fastened roofing system where the membrane is secured through the existing metal roof directly to the structural purlins is recognized as an appropriate recovery system when installed per the recommendations of FM. As a standard FM Approvals requirement,additional membrane and insulation securement is necessary in the corner and/or perimeter areas as outlined in FM Property Loss Prevention Data Sheets 1-28,1-29 and 1-31.These bulletins should be reviewed in their entirety for specific requirements concerning insulation types,fastening enhancements and other items that may be necessary. FM Approvals—Metal Retrofit 6„ 1-135 1 120 60 Inches HP Partin/Piranha 272454-0-0 1-75 12" 1-75 272513-0-0 1-120 120 Inches HP PurlislPiranha 6" 272710-0-0 1-75 1-60 12" 1-60 272642-0-0 138 inches HP Purlin/Piranha 6" 1-105 1-75 272663-0-0 (RoofNAV Number)-For selected systems using 1/4"thick Gypsum top layer. FM Approvals—Metal Retrofit Pressure-Sensitive RUSS Strip - EXTRA or Sure-Weld HS Spectro-WWeld 601nches HP Purlin/Piranha 12' 1 120 1-75 272568-0-0 1-120 1 75 120 Inches HP PurliniPiranha 6 272563-0-0 1-75 12" 1 G0 272576-0-0 (RoofNAV Number)-For selected systems using 1/4"thick Gypsum top layer. FM Approvals—Induction Welding Metal Retrofit 5' 12" 1-75 373501-0-0 Structural Steel Purlin HP Purim RhinoBond 5' 6„ 1-135 (Metal Retrofit) 373505-0-0 10' 6" 1-75 373498-0-0 (RoofNAV Number)-For selected systems using 1/4"thick Gypsum top layer. «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 13 of 44 z / O S 8 ASPEN BUILDING DEPARTMENT Sure-Weld°(TPO)Adhered Roofing Systems UL Approval-Non-Combustible-ANSI/UL 790 Spread of Flame Test(Class A) .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) Type: .060"or.080"Spectro-Weld Reinforced Membrane(White) Non-Combustible:Steel;St.Concrete;Gypsum;Tectum(.Min.2"thick) Maximum Slope ■I Cover Board Sure-Weld or Spectro-Weld Sure-Weld HS Sure-Weld EXTRA Insulli ase,SecurShield,SecurShield HD, SecurShield HD Plus or SecurShield liD Composite- N/A 1/4" any combination,any thickness Any UL Classified EPS or XPS Insulation,any Minimum 1/2 SecurShield HD, 2 SecurShield HID Plus or SecurShield U4' 1;_' 114" thickness HD Composite Minimum 1"layer of InsulBase,SecurShield,or SecurShield HI)Composite over any UL Classified 3 N/A U4' 1;2' 1/4" EPS or XPS Insulation,maximum 1.25 pcf,any thickness Insulfoam HD Composite or Insulfoam HD ,t Non- Composite over Insulfoam EPS,any thickness and N/A 1,a' 1 1/4" Combustible density. _ Any UL Classified Insulation,any thickness Minimum 1/4"SECUROCK®Gypsum• 3, z 2-1l2" (OPTIONAL) Fiber Any UL Classified Insulation,any thickness Minimum 1/4"DensDeck Prime Roof 3" Lnlinu[rd 2-1/2" (OPTIONAL) Boards Any UL Classified Insulation,any thickness Minimum 1/2"HP Recovery Board 1.1/2" 1/4" (OPTIONAL) Minimum 7/16"APA Rated OSB 8 Any UL Classified Insulation,any thickness or 1.1/2" 14" (OPTIONAL) Minimum 1-1/2"StormBaae Cellular 9 Lightweight N/A N/A 3" Unlimited Concrete Structural 10 (poured-in- N/A N/A 3" Unlimited 2-112" place)concrete «TABLE OF CONTENTS RECEIVED 600163-SN'Codes Page 14 of 44 1�/2glz /2018 ASPEN BUILDING DEPARTMENT Sure-Weld*(TPO)Adhered Roofing Systems UL Approval-Combustible-ANSUUL 790 Spread of Flame Test(Class A) .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) Membrane .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Combustible:7/16-in.(minimum)thick non-veneer APA-rated sheathing(oriented strand board panels,structural particleboard panels,composite panels or waferboard panels);15/32-in. (minimum)thick plywood 3/4 in.(minimum)wood;Tectum(less than 2"thick) Maw Slope Thermal Barrier/ System1DBase Sheet Imdatioa - Board(2ti) se'e-weld orS. ' weld HS Sure-weld EXTRA Combustible-ANSI/UL 790 Spread of Flame Test-Class A Minimum 1/4" 1 SECUROCK®Gypsum Fiber Any UL Classified Carlisle Polyisocyanurate Insulation, N/A 1 f4 1 I;4" or Glass Mat Roof Boards any combination,any thickness. (25) Minimum 1/4" Any UL Classified Carlisle Polyisocyanurate Insulation, 2 DensDeck/DensDeck Prime N;A 1,4" 1/2" 1/4" Roof Boards(25) any combination,any thickness. Minimum 3"layer or two layers of 1-1/2"SecurShield 3 N/A 1/4" 1/2" 1/4" or SecurShield HD Composite.(25)(27) N1A Minimum 2-1/2"layer SecurShield or SecurShield HID 4 N/A Composite over a 2-1/2""(minimum)layer of Carlisle N/A 1:4 InsulBase Insulation.(25)(28) Minimum 1-9/10"layer of SecurShield or SecurShield 5 Carlisle FR Base Sheet N/A 1/4 1S 14' HD Composite.(25)(28) Minimum 2-1/2'"'layer of any UL Classified Carlisle Minimum 1/2" 6 \/, SecurShield HD or 1 2' Polyisocyanurate Insulation,any combination.(25) I'4" 1/4" SecurShield HD Plus Minimum 1-1/4"layer of any UL Classified Carlisle Minimum 1/2' 7 Carlisle FR Base Sheet SecurShield HD or 1;4 1 1/4" Polyisocyanurate Insulation,any combination.(25) SecurShield HD Plus 8 N/A Minimum I"layer of SecurShield CD. (25X29) N/A 1 2" 1/4" Minimum 4"layer of any UL Classified EPS Insulation. Minimum 1/2" N/A SecurShield HD or ::4 1= 1/4" (25)(30) SecurShield HD Plus Minimum 1"layer of SecurShield CD over a minimum 10 N/A 3-1/2"layer of any UL Classified EPS Insulation. N/A 1,2' 1/4" (25)(30) 1 I \':'A Minimum 1-1/2"layer of Insulfoam HD Composite N/A - 1/2" 1/4" over a minimum 3"layer of Insulfoam EPS.(25X30) 12 Minimum 2"layer of Insulfoam HD Composite over a N/A 1/2" 1/4" minimum 2-1/2"layer of Insulfoam EPS.(25)(30) - Minimum 1/4" 13 N/A Any UL Classified Carlisle Polyisocyanurate Insulation, SECUROCK® _ 3" 2 1!2" any combination,any thickness. Gypsum Fiber Roof Board(25) Minimum 3/8" 14 N/A Any UL Classified Insulation,any thickness SECUROCK® , 2-1/2" (OPTIONAL) Gypsum Fiber Roof Board(25) Minimum 1/2" 1 N/A Any UL Classified Insulation,any thickness SECUROCK® _ (OPTIONAL) Gypsum Fiber Roof Board(25) RECEIVE1 000163 SW Codes Page 15 of44 1 f211 /2018 ASPEN BUILDING DEPARTMENT Sure-Weld®(TPO)Adhered Roofing Systems UL Approval-Combustible-ANSI/UL 790 Spread of Flame Test(Class A) .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) Membrane .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Type; .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Combustible:7/16-in.(minimum)thick non-veneer APA-rated sheathing(oriented strand board panels,structural particleboard panels,composite panels or waferboard panels);15/32 in, (minimum)thick plywood 3/4 in.(minimum)wood;Tcctum(less than 2"thick) • ID Thermal Barrier/ _er]chard(26) Base Sheet Sure-Weld or Spectro- Sure-Weld HS - Weld Combustible-ANSI/UL 790 Spread of Flame Test-Class A Minimum 1/4" 16 One Ply of Type G2 Any UL Classified Insulation,any thickness SECUROCK® 3„ 3•' 1 2" (OPTIONAL) Gypsum Fiber Roof Board(25) • Any UL Classified Insulation,any thickness Minimum 1/4" 17 N/A (OPTIONAL) DensDeck Prime 3" Unlimited 2-1/2" Roof Board(25) «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 16 of 44 Q.>,/2(y1 z / O 18 ASPEN BUILDING DEPARTMENT Sure-Weld•(TPO)Adhered Roofmg Systems UL Approval-Combustible-ANSI/UL 790 Spread of Flame Test(Class B) .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) Membrane .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) Tom' .060"or.080"Spectra-Weld Reinforced Membrane(White) Combustible:7/16-in.(minimum)thick non-veneer APA-rated sheathing(oriented strand board panels,structural particleboard panels,composite panels or waferboard panels);15/32-in. (minimum)thick plywood 3/4 in.(minimum)wood;Tectum(less than 2"thick) 11=111.xhisun Slope ID Thermal Barrier/Base • Cover. - Sure-W Sheet _tro-We' Combustible-ANSI/UL 790 Spread of Flame Test-Class B Minimum 1-9/10"layer of SecurShield or SecurShield 1 N/A HD Composite.(31)(32) N/A 1/4" N4" Minimum 1-2/5"layer of any UL Classified Carlisle Minimum 1/2"SecurShield 2 N/A Polyisocyanurate Insulation.(31) HD or SecurShield HD Plus 3 N/A Minimum 1"layer of SecurShield CD.(31)(33) N/A ._ One Layer of Carlisle FR Any UL Classified Carlisle Polyisocyanurate Base Sheet Insulation,any combination,any thickness. N/A I __ 1 i4" «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 17 of 44 / O S 8 ASPEN BUILDING DEPARTMENT Sure-Weld®(TPO)Adhered Roofing Systems UL Approval-Combustible and Non-Combustible-ANSI/UL 790 Spread of Flame Test(Class C) Membrane .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Tom' .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Combustible:7/16-in.(minimum)thick non-veneer APA-rated sheathing(oriented strand board panels,structural particleboard panels,composite panels or waferboard panels);15/32-in. (minimum)thick plywood 3/4 in.(minimum)wood;Tectum(less than 2"thick) Non-Combustible:Steel,St.Concrete,Gypsum or Tectum(Min.2"thick) Thermal � SystemID rrier/Base Sheet Insulation Cover Board Weld -Weld E Combustible-ANSI/UL 790 Spread of Flame Test-Class C Any combination,any thickness of N/A UL Classified Carlisle N/A Unlimited Unlimited Unlimited Polyisocranurate Isolation Non-Combustible-ANSI/UL 790 Spread of Flame Test-Class C Any combination,any thickness of I N/A UL Classified Carlisle N/A Unlimited Unlimited Unlimited Polyisocyanurate Insulation. <<TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 18 of 44 /2(y1 z / O 18 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems SecurShield HD Ratings- New Construction .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spector-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST 100LV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Base and Top Layer Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Base Layer Sure-Weld or Sure-Weld Sure-W 1111P I;ase Insulation Layer Fastening Top Ins Layer Fastening (Max.thickness 36") (mechanically fastened Layer (mechanically fastened see Rating SpectrO-Weld EXTRA 2223&24) see notes 22,23&24) !MI I RoofNAV Number Steel Deck(Min.22 Gauge) Min.1-12"InsulBase Polyiso or Loose laid 1/2"SecurShield HD 12(2.67 sq.ft) 1-75 295747-0-0 295747-0-0 295747 0 U SecurShield Min.1-12"InsulBase Polyiso or Loose lard 1/2"SecurShield HD 16(2 sq.ft) 1-90 385909-0-0 - - SecurShield Min.1-1/2"InsulBase Polyiso 10(3.2 sq.ft.) 1/2"SecurShield HD 6"ribbons of FAST 1-90 353874-0-0 353916-0-0 353918-0-0 SWBA Only SWBA Only Min.2"InsulBase Polyiso 8(4 sq.ft) 1/2"SecurShield HD 6"ribbons of FAST 1-90 353875-0-0 353917-0-0 353919-0-0 LVOC Only LVOC Only - Min.1-1/2"InsulBase Polyiso 18(1.8 sq.ft.) 1/2"SecurShield HD 6"ribbons of FAST 1-105 325939-0-0 326014-0-0 LVOC Only LVOC Only Min.1-1/2"InsulBase Polyiso 24(1.33 sq.ft.) 1/2"SecurShield HD 6"ribbons of FAST 1-150 325941-0-0 326019-0-0 - SWBA Only SWBA Only Min.1-1/2"InsulBase Polyiso 24(1.33 sq.ft.) 12"SecurShield HD 4"ribbons of FAST 1-165 325940-0-0 326017-0-0 LVOC Only LVOC Only Min.1/2"DensDeck Prime or 16(2 sq.ft.) 1/2"SecurShield HD over 6'ribbons FAST 1-90 - - SecurockInsulBase Polyiso F Steel Deck(Min.22 Gauge)/VapAir Seal 725TR with Cav-Grip Primer Min.1/2"DensDeck Prime or 16(2 sq.ft.) 112"SecurShield HD over 6„ribbons of FAST 1-90 - - Securock InsulBase Polyiso Concrete Deck Min.12"InsulBase Polyiso 12"ribbons of FAST 12"SecurShield HD 12"ribbons of FAST 1-225 381226-0-0 382997 0-0 382998 0 0 Min.12"InsulBase Polyiso 12"ribbons of 12"SecurShield HD Olybond ribbons of 1-240 Olybond 500 BA 500 BA 1 12" Min.12"InsulBase Polyiso Hot Asphalt 1/2"SecurShield HD Hot Asphalt l 240 - - Concrete Deck/VapAir Seal 725TR with Cav-Grip Primer,Carlisle 702 LV Primer or Carlisle 702 PrimerME I 1-240 364507-0-0 364508-0-0 364509-0-0 Cav-Chip SWBA Only SWBA Only SWBA Only 1-225 364523-0-0 CavGrip LVOC Only - - Min.12"InsulBase Polyiso 12"ribbons of FAST 1/2"SecurShield HD 12"ribbons of FAST 364526-0-0 364621-0-0 364635-0-0 1-195 SWBA Only SWBA Only...........-.SWBA Only ... 702 LV 364525-0-0 364620-0-0 364637-0-0 LVOC Only LVOC Only LVOC Only 1-90 702 - - RECEIVED 600163-SW Codes Page 19 of 441 Q.(/21l z / O 18 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems SecurShield HD Ratings- New Construction .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectra-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST 100LV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Base and Top Layer Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Base Layer Sure-Weld or Sure-Weld Slue-W MIIIMI Fse Insulation Layer Fastening Top Insulation �"P Layer Fastening (Max,thickness 36") (mechanically fastened Layer (mechanically fastened see Rating Spectro-Weld EXTRA Hoke 22,23&24) see notes 22,23&24) RoofNAV Number _ Concrete Deck/SureMB 90TG or 120TG Base Torch Applied/Cut-Back Asphalt Primer Min.1/2"InsulBase Polyiso or Min. 392965-0-0 392966-0-0 392967-0-0 1-1/2"SecurShield 12"ribbons of FAST 1/2"SecurShield HD 12'.ribbons of I':AST I-240 SWBA Only SWBA Only SWBA Only Tectum Deck Min.I.1/2"InsulBase Polyiso Full-Coverage of FAST 1/2"SecurShield HD Full-Coverage of FAST 1 150 - - - Min.1-1/2"InsulBase Polyiso 12"ribbons of 1/2"SecurShield HD 12"ribbons of 1-90 Olybond 500 BA Olybond 500 BA IMM MII Gypsum Deck Tear-Off Min.1.1/2"InsulBase Polyiso 12"ribbons of 1/2"SecurShield HD 12"ribbons of I ni - - Olybond 500 BA Olybond 500 BA MN Cellular Lightweight Insulating Concrete/Steel Decking(Min.22 Gauge( FM Approved Loose laid 1/2"SecurShield HD 12(2.67 sq.ft) 1-75 - - - FM Approved Loose laid 1/2"SecurShield HD 16(2 sq.ft) 1-90 - - - - - 1/2"SecurShield HD 12(2.67 sq.ft) 1-75 - - - - - 1/2"SecurShield HD 16(2 sq.ft) 1-90 - - - - 4"ribbons of FAST 1/2"SecurShield HD 4"ribbons of FAST 1-135 - - - - - 1/2"SecurShield HD 4"ribbons of FAST 1-135 - - - 7 (Celcore)Cellular Lightweight Insulating Concrete/Concrete Decking Min.1/2"InsulBase Polyiso 4"ribbons of FAST I/2"SecurShield HI) 4"ribbons of FAST 1-135 - - - - - 1/2"SecurShield HD 4"ribbons of FAST 1-135 - - - «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 20 of 441 Q.(/211 i/ O 18 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems SecurShield HD Ratings- Recover .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane'Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST lOOLV,Flexible FAST,FAST Bag in a Box.FAST Dual Cartridge and FAST Dual Tank Base and Top Layer Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Base Insulation Layer Base Layer Fasten7Top insulation Top Layer Fastening Sure-Weld or Sure-Weld Sure-Weld (Max.thickness 36") (mechanically fastened see Layer (mechanically fastened see Rating Spectro-Weld EXTRA HS d notes 22,23&24) notes 22,23&24) RootNAV Number dilli Steel Deck(Min.22 Gauge) - - 1/2"SecurShield HD 12(2.67 sq.ft) 1-75 299384-0-0 299384 0 0 29938-0 0 - - 1/2"SecurShield HD 16(2 sq.ft) 1-90 - - - 1/2"SecurShield HD 6"ribbons of FAST 1-90 - - - 1/2"SecurShield HD 4"ribbons of FAST 1-150 - Concrete Deck Min.Dr InsulBase Polyiso 6"ribbons of FAST 1/2"SecurShield HD 6"ribbons of FAST 1-150 - - - 1/2"SecurShield HD 6"ribbons of FAST 1-150 389428-0-0 389430 0 0 359429 0 0 TeclmnDeck - 1/2"SecurShield HD Full-Coverage FAST 1-150 - - 1/2"SecurShield HD 6"ribbons of FAST I-90 - - 1/2"SecurShield HD 4"ribbons of FAST 1-150 - - 1/2"SecurShield HD 12"ribbons of 1-90 Olybond 500 BA Gypsum Deck Tear-Off - - 1/2"SecurShield HD 6"ribbons of FAST 1-90 386254-0-0 386255-0-0 - - 1/2"SecurShield HD 12"ribbons of 1-90 - - Olybond 500 BA «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 21 of44 Q.(/2(il1 / O 18 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems SecurShield HD Plus Ratings- New Construction .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST TOOL V,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Base and Top Layer Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) li Sure-Weld ■L Base Layer Fastening Top Layer Fastening or Spectro- Sure-Weld ore- • (merhankally fastened see Top Insulation Layer (mxmdraIly fastened see Rating Weld i noise 22,23&24)d metes 22,23&24) Steel Deck(Min.22 Gauge) Min.I-1/2"InsulBase Polyiso or Loose laid 1/2"SecurShield HD Plus 8(4 sq.ft) 1-90 325933-0-0 326002-0-0 SecurShield Min.I-1/2"InsulBase Polyiso or 325934-0-0 326005-0-0 Loose laid 1/2"SecurShield HD Plus 18(1.8 sq.ft) 1-120 SecurShield LVOC Only LVOC Only Min.1-1/2"InsulBase Polyiso or 325936-0-0 326024-0-0 Loose laid 1/2"SecurShield HD Plus 24(133 sq.ft) 1-150 SecurShield SWBA Only SWBA Only 1 - Min.1-1/2"InsulBase Polyiso se]aid 1/2"SecurShield HD Plus 24(1.33 sq.fr) 1-225 325937-0-0 326010-0-0 or SecurShield (35) LVOC Only LVOC Only Min.1-1/2"InsulBase Polyiso or 353916-0-0 353918-0-0 10(3.2 sq.ft.) 1/2"SecurShield HD Plus 6"ribbons of FAST 1-90 353874-0-0 SecurShield SWBA Only SWBA Only Min.2"InsulBase Polyiso 8(4 sq.ft) 1/2"SecurShield HD Plus 6"ribbons of FAST 1-90 353875-0-0 353917-0-0 353919-0-0 LVOC Only LVOC Only Min.1-1/2"InsulBase Polyiso 18(1.8 sq.ft.) 1/2"SecurShield HD Plus 6"ribbons of FAST 1-105 - - - Min.1-1/2"InsulBase Polyiso 24(1.33 sq.ft.) 1/2"SecurShield HD Plus 4"ribbons of FAST 1-150 - - Min.1-1/2"InsulBase Polyiso 24(1.33 sq.ft.) 1/2"SecurShield HD Plus 4"ribbons of FAST 1-165 Min.1/2"DensDeck Prime or 16(2 s9 @) 1/2"SecurShield HI)Plus 6"ribbons of FAST 1-90 Securock over lnsulBasc Polyiso .- Steel Deck(Min.22 Gauge)/VapMr Seal 725TR with Cav-Grip Primer Min.1/2"DensDeck Prime or 16(2 sq.ft.) 1/2"SecurShield HD Plus 6"ribbons of FAST I-90 - - - Securock over InsulBase Polyiso Concrete Deck 1 Min.1/2"InsulBase Polyiso 12"ribbons of FAST 1/2"SecurShield HD Plus 12"ribbons of FAST 1-225 381226-0-0 382997-0-0 382998-0 0 Min.1/2"InsulBase Polyiso 12"ribbons of 1/2"SecurShield HD Plus 12"ribbons of 1-240 Olybond 500 BA Olybond 500 BA Min.1/2"InsulBase Polyiso Hot Asphalt 1/2"SecurShield HD Plus Hot Asphalt 1-240 - - - _ Concrete DeckfVapAir Seal 725TR with Cav-Grip Primer,Carlisle 702 LV Primer or Carlisle 702 Primer 364507-0-0 364508-0-0 364509-0-0 1-255 SWBA Only SWBA Only SWBA Only ..................................................................................................................... Cav-Gnj, 364523-0-0 LVOC Only 364526-0-0 364621-0-0 364635-0-0 Min.1/2"InsulBase Polyiso or 12"ribbons of FAST 1/2"SecurShield HD Plus 12"ribbons of FAST 1-195 SWBA Only SWBA Only LVOC Only Min.1-1/2"SecurShield ».........................................»...............»..»..»..»..»..».........»..»............................, 702 LV 364525-0-0 364620-0-0 364637-0-0 LVOC Only LVOC Only SWBA Only 1-90 702 - - - RECEIVED 600163-SW Codes Page 22 of 44 1 /2 11/2 018 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofmg Systems SecurShield HD Plus Ratings- New Construction .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST TOOL V,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Base and Top Layer Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Sure-Weld Sure-Weld Sere-W Insulation Layer Base La.er Fastening Top Layer F;: = • or Spectro- (Ma:.thirlmma 36^) ( • op Insulation Layer (mr.dcalb ' - Weld EXTRA RoofNAV Number 11 Concrete Deck/SureMB 90TG or 12011G Base Torch Applied/Cut-Back Asphalt Primer Min.1/2"InsulBase Polyiso or 392965-0-0 392966-0-0 392967-0-0 12"ribbons of FAST 1/2"SecurShield HD Plus 12"ribbons of FAST 1-240 Min.1-1/2"SecurShield SWBA Only SWBA Only SWBA Only 'rectum Deck . M Min.1-1/2"InsulBase Polyiso Full-Coverage FAST I/2"SecurShield HD Plus Full-Coverage FAST 1-150 - - - Min.1-1/2"InsulBase Polyiso 12"ribbons of 1/2"SecurShield HD Plus 12"ribbons of 1-90 Olybond 500 BA Olybond 500 BA i Gypsum Deck Tear-Off Min.1-1/2"InsulBase Polyiso Full-Coverage FAST 1/2"SecurShield HD Plus Full-Coverage FAST 190 - - Min.1-1/2"InsulBase Polyiso 12"ribbons of 1/2"SecurShield HI)Plus 12"ribbons of 1 90 Olybond 500 BA Olybond 500 BA (Celcore)Cellular Lightweight Insulating Concrete/Steel Decking(Min.22 Gauge) FM Approved Loose laid 1/2"SecurShield HD Plus 12(2.67 sq.ft) 1-75 - FM Approved Loose laid 1/2"SecurShield HD Plus 16(2 sq.ft) 1-90 - 1/2"SecurShield HI)Plus 12(2.67 sq.ft) 1-75 • - - 1/2"SecurShield HD Plus 16(2 sq.ft) 1-90 - Min.1-1/2"InsulBase Polyiso 4"ribbons of FAST 1/2"SecurShield HD Plus 4"ribbons of FAST 1-135 - - - 1/2"SecurShield HD Plus 4"ribbons of FAST 1-135 - (Celcore)Cellular Lightweight Insulating Concrete/Concrete Decking Min.1/2"InsulBase Polyiso 4"ribbons of FAST 1/2"SecurShield HI)Plus 4"ribbons of FAST 1-135 - - - 1/2"SecurShield HD Plus 4"ribbons of FAST 1-135 - «TABLE OF CONTENTS RECEIVE 600163-SW Codes Page 23 of 44 /2 1 1 1/2018 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems SecurShield HD Plus Ratings- Recover .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST 1 OOLV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Base and Top Layer Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) 111 il- Base Insulation Layer Layer Fastening Top Layer Fastening Sure-Weld or Sure-Weld Sure-Weld (Max.thickness on 36") hanicaay fastened see Top Insulation Layer (mechanically fastened see Rating Spectre-Weld EXTRA HS notes 22,23&24) notes 22,23&24) ill RoofNAV NumYt" Ill Steel Deck(Min.22 Gauge) - - 1/2"SecurShield HD Plus 8(4 sq.ft) 1-90 - - - 1/2"SecurShield HD Plus 6"ribbons of FAST 1-90 - - - 1/2"SecurShield HI)Plus 4"ribbons of FAST 1-150 - I Concrete Deck 1.1 Min.1/2"InsulBase Polyiso 6"ribbons of FAST 1/2"SecurShield HD Plus 6"ribbons of FAST 1-150 - - - 1/2"SecurShield HD Plus 6"ribbons of FAST 1-150 - TectwnDeck Min.1-1/2"InsulBase Polyiso Full-Coverage FAST 1/2"SecurShield HD Plus Full-Coverage FAST 1-150 - . Min.1.1/2"InsulBase Polyiso 12"ribbons of 1/2"SecurShield HD Plus 12"ribbons of 1-90 Olybond 500 BA Olybond 500 BA Gypsum Deck Tear-Off Min.1-1/2"InsulBase Polyiso Full-Coverage FAST 1/2"SecurShield ID Plus Full-Coverage FAST 1-90 - Min.1-1/2"InsulBase Polyiso 12"ribbons of 1/2"SecurShield HD Plus 12"ribbons of 1-90 Olybond 500 BA Olybond 500 BA «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 24 of 44 1 /2(}I z / 0 1 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems InsulBase Polyiso Ratings- New Construction .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST IOOLV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Base and Top Layer Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Sure-Weld Sure-Weld Sure- Base Layer Fastening Top Layer Fastening r S o- ase Insulation Layer (Max.thickness 36") (mechanically fastened see Top Insulation Layer (mechanically fastened see Ratingis EXTRA Weld H$ notes 22,23&24) notes 22,23&24) RoofNAV Number Steel Deck(Min.22 Gauge) Min.1-1/2"InsulBase Polyiso 16(2 sq.ft) - - 1-90 13221-0-0 13256-0-0 63400-0-0 Min.2"InsulBase Polyiso 8(4 sq.ft) - - 1-90 13222-0-0 13259-0-0 63401-0-0 Min.2"InsulBase Polyiso 20(1.6 sq.ft) - - 1-150 135476-0-0 135474-0-0 135477-0-0 SWBA Only SWBA Only SWBA Only Min.1-1/2"InsulBase Polyiso 10(3.2 sq.ft.) Min.1-1/2"InsulBase Polyiso 12"ribbons of FAST I-90 - - - Min.2"InsulBase Polyiso 8(4 sq.ft) Min.2"lnsulBase Polyiso 12"ribbons of FAST 1-90 188863-0-0 188878-0-0 188900-0-0 Min.1-1/2"InsulBase Polyiso 18(1.8 sq.ft.) Min.1-1/2"InsulBase Polyiso 6"ribbons of FAST I.105 - - - Min.1-1/2"InsulBase Polyiso 24(1.33 sq.ft.) Min.1-1/2"InsulBase Polyiso 4"ribbons of FAST 1-165 - - I Min.1/2"DensDeck Prime or 16(2 sq.ft.) Min.1-1/2"InsulBase Polyiso 12"ribbons of FAST 1-90 - Securock T Steel Deck(Min.22 Gaage)/VapAir Seal 725TR with Cav-Grip Primer Min.1/2"Dcnslkck Prime or 5!8" 16(2 sq.ft.) Min.1-1/2"hrsulBase Polyiso 12"ribbons of FAST 1-105 352057-0-0 - _ Securock IIConcrete Deck Min.1/2"InsulBase Polyiso Full Coverage FAST - 1-315 279654-0-0 279656-0-0 279705-0-0 Min.1-1/2"InsulBase Polyiso 12"ribbons of FAST - 1-480 222698-0-0 222698-0-0 222698-0-0 SWBA Only SWBA Only SWBA Only Min.1/2"htsulBase Polyiso 12''ribbons of 1-315 279654-0-0 279656-0-0 279705-0-0 Olybond 500 BA Min.1/2"InsulBase Polyiso Hot Asphalt - 1 315 279654-0-0 279656-0-0 279705-0-0 Concrete Deck/VapAir Seal 725TR with Cav-Grip Primer,Carlisle 702 LV Primer or Carlisle 702 Primer 1-255 Cav-Grip 1-195 Alin.1-1/2"hlsulBase Polyiso 12"ribbons of FAST 702 LV - 1-90 275361-0-0 275361-0-0 275361-0-0 702 LVOC Only LVOC Only LVOC Only Concrete Deck/SureMB 90TG or 120TG Base Torch Applied/Cut-Back Asphalt Primer Min.1/2"InsulBase Polyiso 12"ribbons of FAST Min.l-1/2"htsulBase Polyiso 12"ribbons of FAST 1-330 - Tectum Deck Min.1-1/2"InsulBase Polyiso 16(2 sq.ft) - - 1-90 93418-0-0 95300-0-0 93419-0-0 1 - Min.2"InsulBase Polyiso Full-Coverage FAST - - 1-150 211688-0-0 224896-0-0 224898-0-0 SWBA Only SWBA Only SWBA Only • 12"ribbons of Min.1-1/2"InsulBase Polyiso Olybond 500 BA - - 1-90 - - - RECEIVED 600163-SW Codes Page 25 of 44 1 /2(l1 1 / O 18 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems InsulBase Polyiso Ratings- New Construction .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST IOOLV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Base and Top Layer Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Sure-Weld Sure-Weld Sure- Base Layer Fastening Top Layer Fastening r Spectro- (Max.thickness 36") (mechanically fastened see Top Insulation Layer (mechanically fastened see Rating Weld EXTRA Weld HS notes 22,23&24) notes 22,23&24) RoofNAV Number Gypsum Deck Tear-Off Min.2"InsulBase Polyiso 8(4 sq.ft) - - 1-90 93423-0-0 95309-0-0 Min.I-1/2"htsuiBasePolyiso Full-Coverage FAST - 1-90 144203-0-0 144202-0-0 144204-0-0 Min.1"InsulBase Polyiso 12''ribbons of 1 90 189744-0-0 189745-0-0 189746-0-0 Ol nd500BA Cellular Lightweight Insulating Concrete/Steel Decking(Min.22 Gauge) Min.1-1/2"InsulBase Polyiso 16(2 sq.ft) 1-90 - Min.2"lnsulBase Polyiso 8(4 sq.ft) - 1-90 • Min.2"InsulBase Polyiso 20(1.6 sq.ft) - 1-150 - Celcore Min.1"InsulBase Polyiso 4"ribbons of FAST - - 1-135 309398-0- 309406-0- 309497-0- 194470 194470 194470 Cellular Lightweight Insulating Concrete/Concrete Decking _ Celcore Min.1"InsulBase Polyiso 4"ribbons of FAST - - 1-135 309997-0-50916 310002-0- 310052-0- 50916 50916 Elastizell Min.1"InsulBase Polyiso tapered 12"ribbons of 1-180 93280-0-50936 96122-0- 93283-0- Olybond 500 BA 50936 50936 «TABLE OF CONTENTS RECEIVED 000163-SW Codes Page 26 of 441 Q.1/2(ll z / 0 18 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems InsulBase Polyiso Ratings- Recover .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) Base and Top Layer FAST=FAST lOOLV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Base Insulation Layer Base Layer Faste ' Top Insulation Top Layer Fastening Sure-Weld or Sure-Weld Sure-We (Max.thickness 36") (mechanically fastened sea Layer (mechanically fastened see Rating Spectro-Weld EXTRA HS notes 22,23&24) notes 22,23&24) RoofNAV Number Steel r-a I rT^ I'lnsulBase Polyiso 20(1.6 sq.ft) - 1-90 164685-0-0 164687-0-0 164695-0-0 1"lnsulBase Polyiso 6"ribbons of FAST - - 1-90 - - - Min.1/2"lnsulBase Polyiso 12"ribbons of - 1_90 278922-0-0 278923-0-0 278925-0-0 Olybond 500 BA Concrete Deck 112"InsulBase Polyiso 12"ribbons of FAST 1-90 - - 'rectum Deck 1"lnsulBase Polyiso 20(1.6 sq.ft) 1-90 - - - 1"InsulBase Polyiso Full-Coverage FAST 1-150 - - - 1"InsulBase Polyiso 12"ribbons of 1-90 Olybond 500 BA Gypsum Deck'rear-Off 1"lnsulBase Polyiso 20(1.6 sq.ft) 1-90 - . - 1"lnsulBase Polyiso Full-Coverage FAST - 1-90 - - 1"lnsulBase Polyiso 12"ribbons of 1-90 - - - - Olybond 500 BA I «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 27 of 44 1 Q{/2Q17s /2018 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems SecurShield and SecurShield HD Composite Ratings- New Construction .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST lOOLV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Base and Top Layer Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Sure-Weld Sure-Weld Sure-Weld Base Insulation Layer Base Layer Fastening Top Layer Fastening or Spectra (Max.thickness 36") (mechanically fastened see Top Insulation Layer (mechanically fastened see Rating Weld EXTRA HS notes 22,23&24) notes 22,23&24) RoofNAV Number AMIMESIMPERI Min.1-1/2"SecurShield or 16(2 sq.ft) - 1-90 188569-0-0 188569-0-0 188569-0-0 SecurShield HD Composite Min.2"SecurShield or 8(4 sq.ft) - - 1-90 188870-0-0 188870-0-0 188870-0-0 SecurShield HD Composite Min.2"SecurShield or 20(1.6 sq.ft.) - - 1-150 135476-0-0 135476-0-0 135476-0-0 SecurShield HD Composite SWBA Only SWBA Only SWBA Only 1-225 245513-0-0 245509-0-0 245516-0-0 Min.2"SecurShield Only 32(1 sq.ft.) - (35) SWBA Only SWBA Only SWBA Only Min.1-1/2"InsulBase Polyiso 10(32 sq.ft.) Min.1-1/2"SecurShield or 12"ribbons of FAST 1-90 - -SecurShield HD Composite Min.2"InsulBase Polyiso or 8(4 sq.ft) Min.2"SecurShield or 12"ribbons of FAST 1-90 254630-0-0 254630-0-0 2546 30-0-0 SecurShield SecurShield HD Composite Min.1-1/2"InsulBase Polyiso 18(1.8 sq.ft.) Min.1-1/2"SecurShield or 6"ribbons of FAST 1-105 SecurShield HD Composite Min.1-1/2"InsulBase Polyiso 24(133 sq.ft.) Min.1-IY2"SecurShield or 4"ribbons of FAST 1-165 SecurShield HD Composite Min.1/2"DensDeck Prime or 16(2 sq ft) Min.1-1/2"SecurShield or 6"ribbons of FAST I-90 Securock SecurShield HD Composite Steel Deck(Min.22 Gauge)/VapAir Seal 725TR with Cav-Grip Primer Min.1/2"DensDeck Prime or 16(2 sq ft) Min.1-1/2"SecurShield or 12"ribbons of FAST I-1 U5 352057 0 0 5/8"of Securock SecurShield HD Composite Concrete Deck law Min.1/2"InsulBase Polyiso 12"ribbons of FAST Min.2"SecurShield or 12"ribbons of FAST 1-225 323655-0-0 SecurShield HD Composite Min.2"SecurShield or 12"ribbons of 1-240 SecurShield HD Composite Olybond 500 BA Min.2"SecurShield or Hot Asphalt - - I-300 SecurSbield HD Composite IConcrete Deck/VapAir Seal 725TR with Cav-Grip Primer,Carlisle 702 LV Primer or Carlisle 702 Primer 1-255 Cav-Grip Min.1/2"SecurShield or 12"ribbons of FAST _ 1-195 SecurShield HD Composite 702 LV 1-90 702 RECEIVED 600163-SW Codes Page 23 of 44 Z Q.>,/2(}I1 / O S 8 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems SecurShield and SecurShield HD Composite Ratings- New Construction .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST 100LV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Base and Top Layer Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Sure-Weld Sure-Weld Sure-Weld Base Insulation Layer Base Layer Fastening Top Layer Fastening or Spectra (Max.thickness 36") (mechanically fastened see Top Insulation Layer (mechanically fastened see Rating Weld EXTRA HS notes 22,23&24))L notes 22,23&24) RoofNAV Number Concrete Deck/SureMB 90TG or 120TG Base Torch Applied/Cut-Back Asphalt Primer Min.1/2"InsulBase Polyiso 12"ribbons of FAST Min.2"SecurShield or 12"ribbons of FAST 1-330 -SecurShield HD Composite Tectum Deck ' Min.l-1/2"SecurShield or [ l6(2sft)q. 90 SecurShield HD Composite Min.1-1/2"SecurShield or Full-Coverage FAST - - 1-150 - SecurShield HD Composite Min.1-1/2"SecurShield or 12"ribbons of SecurShield HD Composite Olybond 500 BA 19U Gypsum Deck Tear-Off Min.1-1/2"SecurShield or 16(2 sq.ft) - - 190 SecurShield HD Composite Min.1-1/2"SecurShield or Full-Coverage FAST I-90 SecurShield HD Composite • Min.1-1/2"SecurShield or 12"ribbons of SecurShield HD Composite Olybond 500 BA 1-90 Cellular Lightweight Insulating Concrete/Steel Decking(Min.22 Gauge) Min.1-1/2"SccurShicld or 16(2 sq.ft) - 1-75 - SecurShicld HD Composite Min.2"SecurShield or 8(4 sq.ft) - 1-90 SecurShield HD Composite Min.2"SecurShield or 20(1.6 sq.ft.) - 1-150 SecurShield HD Composite Min.2"SecurShield or 32(1 sq.ft.) 1-225 - SecurShield HD Composite Min.1-1/2"SecurShield or q^ribbons of FAST 1-135 SecurShield HD Composite (Celcore)Cellular Lightweight Insulating Concrete/Concrete Decking Min.1/2"SecurShield or 4"ribbons of FAST - 1-135 SecurShield HD Composite «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 29 of 44 1 / O S 8 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems SecurShield Ratings- Recover .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectra-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) Base and Lop Layer FAST=FAST IOOLV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Base Insulation Base Layer Fastening Top Insulation Top Layer Fastening Sure-Weld or Sure-Weld Sure-Weld Layer (mechanically fastened see Layer (mechanically fastened see Rating Spectro-Weld EXTRA HS (Max.thickness 36") notes 22,23&24) rotes 22,23&24) RoofNAV Number Steel Deck(Min.22 Gauge) 1"SecurShield 20(1.6 sq.ft) - I Sri Concrete Deck 1/2"SecurShield 12"ribbons of FAST - 190 1 ectum Deck 1"SecurShield 20(1.6 sq.ft) - 1 90 1"SecurShield Full-Coverage FAST - 1150 1"SecurShield 12"ribbons of 190 Olybond 500 BA Gypsum Deck Tear-Off 1"SecurShield 20(1.6 sq.ft) - - 190 1"SecurShield Full-Coverage FAST - 1 90 1"SecurShield 12"ribbons of 1 90 Olybond 500 BA «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 30 of 44 1 Q.�12(}1 z / 0 S 8 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems Securock Ratings- New Construction .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST lOOLV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Base and Top Layer Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Base Layer Fastening Top Layer Fastening Sure-Weld or Sure-Weld Base Insulation Layer Top Insulation S (mechanically fastened see hanically fastened Rating Spectro-Weld EXTRA (Max.thickness 36") notes 22,23&24) Lay¢r (mecnotes 22,23&24 RoofNAV Number Steel Deck(Min.22 Gauge) Min.1-1/2"InsulBase Polyiso Loose laid Min.1/4"Securock 12(2.66 sq.ft) 1-75 269962-0-0 269964-0-0 269968-0-0 LVOC Only LVOC Only LVOC Only 10(3.2 sq.ft) Min.1-1/2"InsulBase Polyiso Loose laid Min.1/4"Securock 1-90 - SecurFAST Plate Min.1-1/2"InsulBase Polyiso Loose laid Min.3/8"Securock 1-90 - - SureFAST Plate Min.1-1/2"InsulBase Polyiso Loose laid Min.1/2"Securock 10(3.2 sq.ft) 1-90 269985-0-0 269986-0-0 269988-0-0 LVOC Only LVOC Only Min.1-1/2"InsulBase Polyiso Loose laid Min.1/2"Securock 1-90 - SecurFAST Plate Min.1-1/2"InsulBase Polyiso Loose laid Min.1/2"Securock 6(533 sq.ft) 1-75 - - - SecurFAST Plate Min.1-1/2"InsulBase Polyiso Loose laid Min.5/8"Securock 8(4 sq.ft) 1-90 269989-0-0 269990-0-0 269992-0-0 LVOC Only LVOC Only LVOC Only Min.1-1/2"InsulBase Polyiso Loose laid Min.518"Securock 6(533 sq.ft) 1-90 SecurFAST Plate _ Min.1"InsulBase Polyiso Loose laid Min.1/2"Securock 20(1.6 sq.ft) 1-150 269993-0-0 269994-0-0 269996-0-0 LVOC Only Min.1-1/2"lnsulBase Polyiso Loose laid Min.1/2"Securock 32(1 sq.ft) 1-255 239271-0-0 239272-0-0 ^269952-0-0 LVOC Only LVOC Only LVOC Only Min.1-1/2"InsulBase Polyiso 10(32 sq.ft.) Min.1/4"Securock 12"ribbons of FAST 1-90 - 301750-0-0 301753-0-0 LVOC Only Min.2"InsulBase Polyiso 8(4 sq.ft) Min.1/4"Securock 12"ribbons of FAST 1-90 - - - Min.1-1/2"lnsulBase Polyiso 18(1.8 sq.ft.) Min.1/4"Securock 6"ribbons of FAST 1-105 - or Dual Tank Min.1-1/2"InsulBase Polyiso 24(1.33 sq.ft.) Min.1/4"Securock 4"ribbons of FAST 1-165 - Min.1/2"DensDeck Prime or 16(2 sq.ft.) Min.1/4"Securock over 12"ribbons of FAST 1-105 - Securock Min.1/2"InsulBase Polyiso Steel Deck(Min.22 Gauge)/VapAir Seal 725TR with Cav-Grip Primer Min.1/2"DensDeck Prime or Min.1/4"Securock over 16(2 sq.ft.) 12'ribbons of FAST 1-90 327597-0-0 - - 5/8"Securock Min.1/2"InsulBase Polyiso Concrete Deck w. Min.1/2"InsulBase Polyiso FAST Full Coverage Min.1/4"Securock FAST Full Coverage 1-315 307662-0-0 307751-0-0 307702-0-0 _ SWBAOnly SWBAOnly _ SWBAOnly _ Min.1-1/2"InsulBase Polyiso 12"ribbons of Min.1/4"Securock 12"ribbons of 1 240 301747-0-0 301755-0-0 301761-0-0 Olybond 500 BA Olybond 500 BA LVOC Only LVOC Only LVOC Only Min.1/2"InsulBase Polyiso Hot Asphalt Min.1/4"Securock Hot Asphalt 1-300 - - - RECEIVED 600163-SW Codes Page 31 of 44 1 /2 1 /2 0 18 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems Securock Ratings- New Construction .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST IOOLV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Base and Top Layer Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Base Layer Fastening Top Layer Fastening Sure-Weld or Sure-Weld Base Insulation Layer Top Insulation S (mechanically fastened see (mechanically fastened see Rating Spectro-Weld EXTRA (Max.thiclmess 36") Layer notes 22,23&24) notes 22,23&24) .si is. i oofNAV Number Concrete Deck/VapAir Seal 725TR with Cav-Grip Primer,Carlisle 702 LV Primer or Carlisle 702 Primer I 1-255 333171-0-0 364616-0-0 364627-0-0 Cav-Grip LVOC Only LVOC Only Min.1/2"InsulBase Polyiso 12"ribbons of FAST Min.1/4"Securock 12"ribbons of FAST 1-195 364524-0-0 364619-0-0 364633-0-0 702 LV LVOC Only LVOC Only LVOC Only 1-90 286420-0-0 285982-0-0 286420-0-0 702 LVOC Only LVOC Only LVOC Only I Concrete Deck/SureMB 90TG or 120TG Base Torch Applied/Cut-Back Asphalt Primer Min.1/2"InsulBase Polyiso 12"ribbons of FAST Min.1/4"Securock 12"ribbons of FAST 1330 - - - Tectum Deck Min.1-1/2"InsulBase Polyiso Full-Coverage FAST Min.1/4"Securock Full-Coverage FAST 1-150 - 12"ribbons of 12"ribbons of Min.1-1/2"InsulBase Polyiso 1 90 Olybond 500 BA Min.1/4"Securock Olybond 500 BA Gypsum Deck Tear-Off r Min.1-1/2"InsulBase Polyiso Full-Coverage FAST Min.1/4"Securock Full-Coverage FAST 1-90 - Min.1-1/2"InsulBase Polyiso 12"ribbons of Min.1/4"Securock l2°ribbons of 1-90 Olybond 500 BA Olybond 500 BA _ Cellular Lightweight Insulating Concrete/Steel Decking(Min.22 Gauge) FM Approved Loose laid Min.1/4"Securock 12(2.67 sq.ft) 1-75 - - FM Approved Loose laid Min.1/2"Securock 10(3.2 sq.ft) 1-90 - - FM Approved those laid Min.5/8"Securock 8(4 sq.ft) 1-90 - - FM Approved Loose laid Min.1/2"Securock 20(1.6 sq.ft) 1-150 - - FM Approved those laid Min.1/2"Securock 32(1 sq.ft) 1-225 - - Min.1-1/2"InsulBase Polyiso 4"ribbons of FAST Min.1/2"Securock 4"ribbons of FAST 1-135 - - - (Celcore)Cellular Lightweight Insulating Concrete/Concrete Decking Min.I"InsulBase Polyiso 12"ribbons of FAST Min.1/4"Securock 12"ribbons of FAST 1-135 310009-0-50914 310012-0-50914 310049-0-50914 <<TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 32 of 441 Q.(/21 Iz / 0 18 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems Securock Ratings- Recover .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectra-Weld Reinforced Membrane(White) Membrane Adhesive: Sum-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) Base and Top Layer FAST=FAST lOOLV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) ase Insulation Base Layer Fastening Top Insulation op Layer Fastening Sure-Weld or Sure-Weld Sure-Weld Layer (mechanically fastened see Layer chamcally fastened see Rating Spectro-Weld EXTRA HS .thickness 36") notes 22,23&24) notes 22,23&24) RoofNAV Number ■ Steel Deck(Min.22 Gauge) A 1I2"InsulBasc Polyiso 10(32 sq.ft) Min.1!4"Securock 12"ribbons of FAST or 1-90 301766-0-0 288835-0-0 288837-0-0 OlyBond 500 BA LVOC Only LVOC Only LVOC Only <<TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 33 of 44 / O ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems DensDeck Prime Ratings- New Construction .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST IOOLV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Base and Top Layer Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Sure-Weld Sure-Weld Sure-Weld Base Layer Fastening Top Layer Fastening or S ectro- e Insulation Layer (mechanically fastened see Top Insulation Layer (mechanically fastened see Rating p EXTRA HS (Max.thickness 36") notes 22,23&24) notes 22,23&24) Weld dr RootNAV Number MIL lini Steel Deck(Min.22 Gauge) Min.1-1/2"InsulBase Polyiso Loose laid Min.1/4"DensDeck Prime 12(2.67 sq.ft) 1-90 92102-0-0 95279-0-0 92103-0-0 or SecurShield Min.1-1/2"InsulBase Polyiso or Loose laid Min.1/2"DensDeck Prime 10(3.2 sq.ft) 1-90 92073-0-0 95221-0-0 92074-0-0 SecurShield Min.1-1/2"InsulBase Polyiso Loose laid 5/8"DensDeck Prime 8(4 sq.ft) 1-90 92098-0-0 95274-0-0 92099-0-0 or Securshield Min.1-1/2"InsulBase Polyiso Loose laid Min.1/2"DensDeck Prime 8(4 sq.ft) 1-90 388249-0-0 388251-0-0 Min.1-1/2"InsulBase Polyiso Loose laid Min.1/4"DensDeck Prime 18(1.8 sq.ft) 1.105 382309-0-0 382310.0-0 Min.1-1/2"InsulBase Polyiso Loose laid Min.1/2"DensDeck Prime 18(1.8 sq.ft) 1-135 383699-0-0 383700-0-0 Min.1-1/2"InsulBase Polyiso Loose laid Min.1/2"DensDeek Prime 20(1.6 sq.ft) 1.150 383709-0-0 383710-0-0 Min.1-1/2"InsulBase Polyiso Loose laid Min.1/2"DensDeck Prime 32(1 sq.ft) 1-165 384592-0-0 384594-0-0 80 Min.1-1/2"InsulBase Polyiso Loose laid Min.1/2"DensDeck Prime 32(1 sq.ft) 1(3 384593-0-0 384595-0-0 Min.1-1/2"InsulBase Polyiso Loose laid Min.1/2"DensDeck Prime 32(1 sq.ft) 1-255 387928-0-0 387931-0-0 - (35) Min.1-1/2"InsulBase Polyiso 10(32 sq.ft.) Min.1/4"DensDcck Prime 12"ribbons of FAST 1-90 - - - Min.2"InsulBase Polyiso 8(4 sq.ft) Min.1/4"DensDeck Prime 12"ribbons of FAST 1-90 188976-0-0 188980-0-0 188976-0-0 Min.1-1/2"InsulBase Polyiso 18(1.8 sq.ft.) Min.1/4"DensDeck Prime 6"ribbons of FAST 1-105 - - - Min.1-1/2"InsulBase Polyiso 24(1.33 sq.ft.) Min.1/4"DensDeck Prime 4"ribbons of FAST 1-165 - - Min.1/4"DensDeck Prime Min.1/2"DensDeck Prime 16(2 sq.ft.) over Min.1-1/2"InsulBase 12"ribbons of FAST 1-90 303447-0-0 303448-0-0 303451-0-0 Polyiso J Steel Deck(Min.22 Gauge)NapAlr Seal 725TR with Cav-Grip Primer Min.1/2"DensDeck Prime 16(2 sq.ft.) 1/4"DensDeck Prime over 12"ribbons of FAST 1-90 327597-0-0 - - Min.1/2"InsulBase Polyiso ' Concrete Deck Min.1/2"InsulBase Polyiso 12"ribbons of FAST Min.1/4"DensDeck Prime 12"ribbons of FAST 1-315 - - - Min.1-1/2"InsulBase Polyiso 12"ribbons of Min.1/4"DensDeck Prime 12"ribbons of 1-240 375399-0-0 378777-0-0 378778-0-0 Olybond 500 BA Olybond 500 BA Min.1-1/2"InsulBase Polyiso Hot Asphalt Min.1/4"DensDeck Prime Hot Asphalt 1-300 224136-0-0 224138-0-0 224136-0-0 RECEIVED 600163-SW Codes Page 34 of 441 /211 i/ 018 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems DensDeck Prime Ratings- New Construction .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST IOOLV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Base and"fop Layer Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Base Layer Faste Sure Weld Sure-Weld Sure-Weld e Insulation Layer y Top Layer Fastening or Spectro- (Max.thickness 36") (mechanically fastened see Top Insulation Layer (mechanically fastened see Rating Weld EXTRA HS notes 22,23&24) notes 22,23&24) 1.1 dini d=` AM RoofNAV Number III Concrete Deck/VapAir Seal 725TR with Cav-Grip Primer,Carlisle 702 LV Primer or Carlisle 702 Primer 1-255 333171-0-0 - Cay-Grip Min.1/2" InsulBase Polyiso 12"ribbons of FAST Min.1/4"DensDeck Prime 12"ribbons of FAST 1-195 702 LV 1-90 702 Concrete Deck/SureMB 90TG or 120TG Base Torch Applied/Cut-Back Asphalt Primer Min.1/2"InsulBase Polyiso I 12"ribbons of FAST Min.1/4"DensDeck Prime 12"ribbons of FAST 1-330 - Tectum Deck ___A— Min.1-1/2"InsulBase Polyiso Full-Coverage FAST Min.1/4"DensDeck Prime Full-Coverage FAST 1-150 - Min.1-1/2"InsulBase Polyiso 12"ribbons of Min.1/4"DensDeck Prime 12"ribbons of Ol bond 500 BA Olybond 500 BA 1-90 92503-0-0 94036-0-0 92524-0-0 Gypsum Deck Tear-Off Min.1-1/2"InsulBase Polyiso Full-Coverage FAST Min.1/4"DensDeck Prime Full-Coverage FAST 1-90 157790-0-0 157790-0-0 157790-0-0 Min.1-1/2"InsulBase Polyiso 12"ribbons of FAST Min.I/4"DensDeck Prime 12"ribbons of FAST 1-90 - - - Min.1-1/2"InsulBase Polyiso 12"ribbons of Min.1/4"DensDeck Prime 12"ribbons of 1-90 92638-0-0 94046-0-0 92641-0-0 Olybond 500 BA Olybond 500 BA I Cellular Lightweight Insulating Concrete/Steel Decking(Min.22 Gauge) FM Approved Loose laid Min.1/4"DensDeck Prime 12(2.67 sq.ft) 1-90 - FM Approved Loose laid Min.1/2"DensDeck Prime 10(3.2 sq.ft) 1-90 - FM Approved Loose laid Min.5/8"DensDeck Prime 8(4 sq.ft) 1-90 - Min.1-1/2"InsulBase Polyiso 4"ribbons of FAST Min.1/2"DensDeck Prime 4"ribbons of FAST 1-135 - - - (Celcore)Cellular Lightweight Insulating Concrete/Concrete Decking Min.1"InsulBase Polyiso 12"ribbons of FAST Min.1/4"DensDcck Prime 12"ribbons of FAST 1-I35 310009-0-50914 310012.0- 310049-0- 50914 50914 «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 35 of 44 1 ql'211 i/2 0 18 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems DensDeck Prime Ratings- Recover .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST 100LV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Base and Top Layer Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Sure-Weld Sure-Weld Sure-W Base Insulation Layer Base Layer Fastening Top Layer Fastening or Spectro- (mechanically fastened see Top Insulation Layer (mechanically fastened see Rating EXTRA HS (Max.thickness 36") Weld notes 22,23&24) notes 22,23&24) RoofNAV Number Steel Deck Min.1/2"InsulBase Polyiso 20(1.6 sq.ft) Min.1/4"DensDeck Prime Hot Asphalt 1-90 265212-0-0 265212-0-0 265212-0-0 Concrete Deck Min.1-1/2"InsulBase Polyiso 12"ribbons of Min 1/4"DensDeck Prime 12"ribbons of 1.90 91885-0-0 95011-0-0 91888-0-0 Olybond 500 BA Olybond 500 BA Min.1"InsulBase Polyiso 20(1.6 sq.ft) Min.1/4"DensDeck Prime Hot Asphalt 1-90 265217.0-0 265218-0-0 265217-0-0 «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 36 of 44 /2 1 1 i/2018 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems OSB Ratings- New Construction .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST 100LV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Base and Top Layer Adhesive:(FAST Dual Tank can only be used on Steel and Concrete Decking) " r Sure-Weld Sure-Weld Sure-Weld Base Insulation Layer Base Layer Fastening Top Insulation Top Layer Fastening or Spectro- (mechanically fastened see (mechanically fastened see ling EXTRA HS (Max.thickness 36°) Layer I Weld notes 22,23&24) notes 22,23&24) RootNAV Number Steel Deck(Min.22 Gauge) Min.1-1/2"lnsullasc Polyiso Loose laid MIn.7,16 OSB17(1.9 sq.ft) I-150 13335-0-0 13341-0-0 13335-0-0 SWBA Only SWBA Only SWBA Only Tectum Deck Min.2"InsulBase Polyiso Full-Coverage FAST Min.7/16"OSB Full-Coverage FAST 1-150 224838-0-0 224901-0-0 224838-0-0 SWBA Only SWBA Only SWBA Only Gypsum Deck Tear-Off MIMMIE Min.1-1/2"InsulBase Polyiso Full-Coverage FAST Min.7/16"OSB Full-Coverage FAST 1-90 - - - Min.1-1/2"InsulBase Polyiso 12"ribbons of Min.7/16"OSB 12"ribbons of 190 - Olybond 500 BA Olybond 500 BA Cellular Lightweight Insulating Concrete/Steel Decking(Min.22 Gauge) FM Approved Loose laid Min.7/16"OSB 17(1.8 sq.ft) I 150 - - - <<TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 37 of 44 1 /2(}I z / O S 8 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems OSB Ratings- Recover .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectra-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) Base and Top Layer FAST=FAST 100LV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Sure-Weld Base Insulation Layer Base Layer Fastening Top Insulation Top Layer Fastening or Spectra- Sure-Weld Sure-Wel (Max.thickness 36") (mechanically fastened see Leyet (mechanically fastened see notes Rating Weld EXTRA HS notes 22,23&24) 22,23&24) RooNNAV Number J FM Approved Loose laid Min.7/16"OSB 17(l.8sq.ft) 1-150 - - «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 38 of 44 / O 18 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems HP Recovery Board Ratings- New Construction .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST IOOLV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Base and Top Layer Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Base Layer FasNI. TopLayer Fastening Sure Weld Sure-Weld Sure-Weld e Insulation Layeror Spectro- (Max.thickness 36") (mechanically fastened see Top Imola on Layer (mechanically fastened see Rating EXTRA HS notes 22,23&24) notes 22,23&24) Weld RoofNAV Number Steel Deck(Min.22 Gauge) Min.1-1/2"InsulBase Polyiso Loose laid Min.1/2"HP Recovery Board 16(2 sq.ft) 1-90 212437-0-0 - - Min.1-1/2"InsulBase Polyiso 10(32 sq.ft.) Min.1/2"HP Recovery Board 6"ribbons of FAST 1-90 - - - Min.2"-12"InsulBase Polyiso 8(4 sq.ft) Min.1/2"HP Recovery Board 12"ribbons of FAST 1-90 188976-0-0 188980-0-0 188976-0-0 Min.1/2"HP Recovery Board Min.1/2"DensDeck Prime 16(2 sq.ft.) over Min.1-1/2"InsulBase 12"ribbons of FAST 1-90 303447-0-0 303448-0-0 303447-0-0 Polyiso Steel Deck(Min.22 Gauge)NapAir Seal 725TR with Cav-Grip Primer Min.1/2"DensDeck Prime or 16(2 sq.R.) �.1/2"HP Recovery Board 6"ribbons of FAST 1-90 Securock over lnsulBase Polyiso Concrete Deck Min.1/2"InsulBase Polyiso 12"ribbons of FAST Min.1/2"HP Recovery Board 12"ribbons of FAST 1-315 - - - Min.1-1/2"InsulBase Polyiso 12"ribbons of Min 1/2"HP Recovery Board 12"ribbons of 1 240 230435-0-0 230436-0-0 230435-0-0 Olybond 500 BA Olybond 500 BA SWBA Only SWBA Only SWBA Only Min.1-1/2"InsulBase Polyiso Hot Asphalt Min.1/2"HP Recovery Board Hot Asphalt 1-300 224117-0-0 224118-0-0 224117-0-0 Concrete Deck/VapAir Seal 725TR with Cav-Grip Primer,Carlisle 702 LV Primer or Carlisle 702 Primer 1 ' 1-255 Cay-Grip Min.1/2"InsulBase Polyiso 12"ribbons of FAST Min.1/2"HP Recovery Board 12"ribbons of FAST 1-195 702 LV 1-90 702 Concrete Deck/SureMB 90'FG or 120TG Base Torch Applied/Cut-Back Asphalt Primer Min.1/2"InsulBase Polyiso 12"ribbons of FAST Min.1/2"HP Recovery Board 12'ribbons of PAST 1 330 Tectum Deck Min.1-1/2"InsulBase Polyiso Full-Coverage FAST Min.1/2"HP Recovery Board Full-Coverage FAST 190 Min.1-1/2"InsulBase Polyiso 12"ribbons of Min 1/2"HP Recovery Board 12"ribbons of 1-90 92503 0 0 941)36-0-0 92503-0-0 Olybond 500 BA Olybond 500 BA RECEIVED 600163-SW Codes Page 39 of 44 / O S 8 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems HP Recovery Board Ratings- New Construction .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectro-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) FAST=FAST IOOLV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank Base and Top Layer Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Base Layer Fasten Top Layer Fastening Sure Weld Sure-Weld Sure-Weld e Insulation Layer or re-Weo- (Max.thickness 36") (mechanically fastened see Top Insulation Layer (mechanically fastened see Rating EXTRA HS notes 22,23&24) notes 22,23&24) Weld RoofNAV Number Gypsum Deck Tear-Off Min.1-1/2"InsulBase Polyiso Full-Coverage FAST Min.1/2"HP Recovery Board Full-Coverage FAST 1-90 157790-0-0 157790-0-0 157790-0-0 Min.1-1/2"InsulBase Polyiso 12"ribbons of Min.1/2"HP Recovery Board 12"ribbons of 1-90 91835-0-0 94046-0-0 91835-0-0 Olybond 500 BA Olybond 500 BA Cellular Lightweight Insulating Concrete/Steel Decking(Min.22 Gauge) NMI FM Approved Loose laid Min.1/2"HP Recovery Board 16(2 sq.ft) 1-90 - - Min.I-1/2"InsulBase Polyiso 4"ribbons of FAST Min.1/2"HP Recovery Board 4"ribbons of FAST 1-90 - - (Celcore)Cellular Lightweight Insulating Concrete/Concrete Decking Min 1"InsulBase Polyiso 12"ribbons of FAST Min.1/2"HP Recovery Board 12"ribbons of FAST 1-135 310009-0- 310012-0- 310009-0 50918 50918 50918 «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 40 of 44 / O S 8 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems HP Recovery Board Ratings- Recover .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) Membrane Type: .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectra-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) Base and Top Layer FAST=FAST 100LV,Flexible FAST,FAST Bag in a Box,FAST Dual Cartridge and FAST Dual Tank .Adhesive: (FAST Dual Tank can only be used on Steel and Concrete Decking) Sure-Weld Sure-Weld Sure-Weld Base Layer Fastening Top Layer Fastening or S ctro- Base Insulation Layer (mechanically fastened see Top Insulation Layer limi:otes mechanically fastened see Rating EXTRA HS (Max.thickness 36") notes 22,23&24) 22,23&24) Weld RootNAV Number y y Steel Deck Min.1/2"InsulBase Polyiso 20(1.6 sq.ft) 1/2"HP Recovery Board Hot Asphalt 1-90 265212-0-0 265214-0-0 265212-0-0 Concrete Deck Min.1"InsulBase Polyiso 20(1.6 sq.ft) 1/2"HP Recovery Board Hot Asphalt 1-90 265217-0-0 265218-0-0 265217-0-0 «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 41 of 44 /2 1 1 i/2018 ASPEN BUILDING DEPARTMENT FM Approvals Design"A"Adhered Roofing Systems Lightweight Insulating Concrete - New Construction .045"or.060"Sure-Weld Standard Reinforced Membrane(White,Gray or Tan) Membrane Type: .045"or.060"Sure-Weld HS Reinforced Membrane(White,Gray or Tan) .080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) .060"or.080"Spectra-Weld Reinforced Membrane(White) Membrane Adhesive: Sure-Weld Bonding Adhesive(SWBA)or Low VOC Bonding Adhesive(LVOC) Maximum Slope Lightweight Insulating Rating Sure-Weld or Spectro-Weld Sure-Weld EXTRA Sure-Weld HS Concrete Imia RootNAV Number J[�e: Celcorc 1-135 243956-0-194470 244212-0-194470 1-1/2"Slope 3/4"Slope 191311-0-50936 1-1/2"Slope - - SWBA Only Concrete Elastizell 1-180 173455-0-50936 3/4"Slope - - SWBA Only «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 42 of 44 / O 18 ASPEN BUILDING DEPARTMENT National,State&City Building Code Approvals Authority Approval Approved Systems ICC-International Code Council Report ESR 1463 "A"and"MF' SBCC1 These Code Bodies merged - BOCA to form ICC as of March - 2003 • NES—National Evaluation Service,Inc. Refer to ICC approval "A"and"MF' 1030 "A"and"MF" Dade County(South Florida)Approvals Expires August,2018 Deck Type Acceptance# Lightweight Concrete 14-0626.07 Wood 14-0626.03 Steel 14-062602 Structural Concrete 14-0626.05 Cementitious Wood Fiber 14-0626.04 Gypsum 14-0626.08 Recover 14-0626.06 (Using Sure-Weld Standard or EXTRA Reinforced Membrane) 1. Sure-WeIdTM White and Tan TPO Membranes exceed the requirements for the US.EPA.ENERGY STAR®Program for reflective roofing materials. 2. Sure-WeIdTM TPO Membranes conform to requirements of the US.EPA.Toxic Leachate Test(40 CFR part 136)performed by an independent analytical laboratory. «TABLE OF CONTENTS Carlisle SynTee,a division of Carlisle Construction Materials Incorporated.P.O.Boa 7000,Carlisle,PA 17013 (8001.4SYNTEC(80e.479fi832) Sure-Weld,SpecteoWeld,Sure-Weld EXTRA and Sure-Weld HS are Tradenurks of Carlisle Corporation DensDeck Prime is a Trademark of Georgia-Pacific The contents of this issue represent the applicable information available at the time of publication.The contents of older issues am no longer accurate due to subsequent changes. 2017 Copyright Carlisle SynTec,a division of Carlisle Construction Materials Incorporated RECEIVED 600163-SW Codes Page 43 of 44 / O S 8 ASPEN BUILDING DEPARTMENT SURE-WELD®TPO Reference Notes 1. All insulation joints must be staggered a minimum of 6 inches from the deck joints or from the insulation joints directly. (return to table) 2. Any roof covering system listed for use over a combustible roof deck can be installed over a non-combustible roof deck and achieve the same classification.(return to table) 3. Any UL Classified Carlisle Polyisocyanurate Insulation,any combination,any thickness may be used below the 3"minimum total thickness of SecurShield or SecurShield HD Composite. (return to table) 4. Any UL Classified Carlisle Polyisocyanurate Insulation,any combination,any thickness may be used below the 1-9/10"thickness of SecurShield or SecurShield HD Composite. (return to table) 5. Any UL Classified Carlisle Polyisocyanurate Insulation,any combination,any thickness maybe used below the 1"thickness of SecurShield CD. (return to table) 6. Any UL Classified Insulation,any combination,any thickness,maybe used below the 4-1/2"minimum total thickness. (return to table) 7. All insulation joints must be staggered a minimum of 6 inches from the deck joints or from the insulation joints directly below. (return to table) 8. Any thickness of UL Classified Carlisle Polyisocyanurate Insulation maybe used below the 1-9/10"thickness of SecurShield or SecurShield HD Composite. (return to table) 9. Any UL Classified insulation,any combination,any thickness,may be used below the SecurShield CD. (return to table) 10. For roof deck construction(new,tear-off or retrofit),approved insulations and maximum roof slopes,click here. (return to table) 11. Refer to Carlisle specifications for minimum requirements regarding sheet widths and fastener spacing. (return to table) 12. On steel decks,Carlisle HP-X Fasteners and Piranha Plates or HP-Xtra Fasteners and Piranha Xtra Plates are required as identified in this chart. On structural concrete decks,CD-10,HP Concreate Spikes or HI)14-10 Fasteners are used with Piranha Plates. (return to table) 13. Testing conducted on FM approved 22-gauge Grade E Steel decking(ASTM Designation A611 or A653 Grade 80). Refer to FM requirements for deck installation. (click here for FM requirements)(return to table) 14. Ratings achieved using steel decking attached to structural puffins spaced 5'o.c. (return to table) 15. Please reference for ANSI-SPRI WD-1/ASCE 7-10 for non-FM insured projects,click here. (return to table) 16. For roof deck construction(new,tear-off or retrofit),approved insulations and maximum roof slopes,click here. (return to table) 17. On steel decks,Carlisle HP-X Fasteners and Piranha Plates or HP-Xtra Fasteners and Piranha Xtra Plates are required as identified in this chart. On structural concrete decks,CD-10,HP Concreate Spikes or HD 14-10 Fasteners are used with Piranha Plates. (return to table) 18. The fastener spacing for membrane securement is dependent on the deck type,desired wind uplift rating and the Carlisle Fastening Plate and Fastener utilized as identified,click here for more information. (return to table) 19. Insulation shall be fastened in accordance with Carlisle Specifications. (return to table) 20. On steel decks,a thermal barrier of FM approved gypsum board is required under expanded or extruded polystyrene. For specific thermal barrier requirements,refer to FM's RooiNAV web-site. (return to table) 21. Existing roof must be FM Class 1 rated. (return to table) 22. Sure-Seal HP fastener/Sure-Seal Insulation plate. Click on one of the following to return to chart: SecurShield HD,SecurShield HD Plus, 23. Insu1FAST fastener/Sure-Seal Insulation plate. j- InsulBase Polyiso,SecurShield,SecurShield HD Composite,Securock,DensDeck Prime, 24. InsuIFAST fastener/SecurFAST Insulation Fastening plate. J OSB or HP Recovery Board 25. All insulation joints must be staggered a minimum of 6 inches from the deck joints or from the insulation joints directly below. (return to table) 26. Any roof covering system listed for use over a combustible roof deck can be installed over a non-combustible roof deck and achieve the same classification. (return to table) 27. Any UL Classified Carlisle Polyisocyanurate Insulation,any combination,any thickness may be used below the 3"minimum total thickness of SecurShield or SecurShield HD Composite. (return to table) 28. Any UL Classified Carlisle Polyisocyanurate Insulation,any combination,any thickness may be used below the 1-9/10"thickness of SecurShield or SecurShield HD Composite. (return to table) 29. Any UL Classified Carlisle Polyisocyanurate Insulation,any combination,any thickness may be used below the 1"thickness of SecurShield CD. (return to table) 30.Any UL Classified Insulation,any combination,any thickness,maybe used below the 4-1/2"minimum total thickness. (return to table) 31. All insulation joints must be staggered a minimum of 6 inches from the deck joints or from the insulation joints directly below. (return to table) 32. Any thickness of UL Classified Carlisle Polyisocyanurate Insulation may be used below the 1-9/10"thickness of SecurShield or SecurShield HD Composite.(return to table) 33. Any UL Classified insulation,any combination,any thickness,may be used below the SecurShield CD.(return to table) 34. 80 ksi with one fastemer per attachment point.(return to table) 35. 80 ksi with two fasterners per attachment point.(return to table:SecurShield HD Plus,DensDeck Prime or SecurShield) «TABLE OF CONTENTS RECEIVED 600163-SW Codes Page 44 of 44 1 Q.�17t z / O S 8 ASPEN BUILDING DEPARTMENT RECEIVED 12/1/2018 ASPEN BUILDING DEPARTMENT