Loading...
HomeMy WebLinkAboutFile Documents.1411 Crystal Lake Rd.0062.2018 (6).ARBK DEW POINT CALCULATION � RADER0 z JOB NAME: Smallwood House ® l/I ENGINEERING •COMFORT SYSTEMSINE JOB NUMBER: 17082.00 DATE: 2/21/18 CALCS BY: JSW DP @ DP @ DP @ DP @ DP @ 20% RH 25% RH 30% RH 35% RH 45% RH 30 33 37 41 48 Outdoor design temperature (ODT) 0 Indoor design temperature (IDT) 70 Delta T = IDT- ODT 70 Thermal Resistance of Proposed Roof Assembly Layer R-value Outside air layer 0.17 Roofing 0.00 Roof Underlayment 0.00 3/4" plywood 0.94 3"tapered rigid insulation (R-5/in) 15.00 Spray polyurethane foam insulation 21.00 A: point of condensation analysis Vapor barrier 0.00 Fiber batt insulation 13.00 5/8" gypboard 0.56 Inside air layer 0.61 R-Total 51.28 R-value at A 14.17 TA=Temperature at point A -0,00 LJCF��� TA= IDT- (R-value at A)/(R-Total) * (Delta T) 51 V � PN J'HO•tiAo TO DPA = Dew point at point A(35% RH) 41 m 8�c 2/21/1 ; /t� Is TA warmer than the DPA? YES I i 39,�; 14, • Note: To minimize the potential for condensation problems, •. ..... humidity levels within the home must be properly controlled 4%`ONAL.04 and adjusted based on outdoor temperatures. RECEIVED 3/29/2018 ASPEN BUILDING DEPARTMENT