Loading...
HomeMy WebLinkAboutFile Documents.124 W Hyman Ave.0051.2019 (9).ARBK = Miele 36" Built-In Wall Cabinet Hood DA 3698 ,______ Ov AO,- f REC : N. 03/11/2019 -Imieltlbf73`d4GOfn Pleasehote-This infgrrnation is subject to change s r �.���- TMENT Miele 36" Built-In Wall Cabinet Hood SPECIFICATIONS 1111101 Overall Unit Dimensions 351/8"(892 mm)W x 141/16"(357 mm)H x 123/16"(309 mm)D[Depth Retracted] Unit Depth Extended 181/16"(459 mm) Built-In Minimum Opening Dimensions 221/8"(562 mm)W x 133/4"(350 mm) H x 123/16"(310 mm)D Fan Fan Speeds 4 Maximum CFM 625 CFM,(Reducing Collar is available to reduce Air flow to less than 400 CFM Duct Duct Diameter 6"(150 mm) Electrical Electrical Requirements 120V,60Hz,15A Power Cord Molded NEMA 5-15 plug,2.5 ft(0.75 m) Shipping Shipping Weight 41.8 lbs(19 kg) Shipping Dimensions 377/16"W x 201/2" H x 14" D Support Call Miele 800.843.7231 Miele Website iiwww.mieleusa.com 20/20 Link JC52020technologies.com It DA 3698 Item 28369855USA RECEIVED 03/11/2019 htEtja E 5 BUILDING DEPARTMENT Miele 36" Built-In Wall Cabinet Hood INSTALLATION SPECIFICATIONS (24 /2„ 13/�6') 2r 7 a. 06" O �y03 mm a S,, ^ ^') c<1 (84 e ri-141) 11141 ga 0 9/16 (3, / 3/8 �A) (35 gym) y 492 rn �� 23 (300e., mn,) 4,ax (1 5p5 N., The ducting can also be connected at the back. 2 After installation,the wall unit can be fitted with an interim panel. If this is done, make sure that the slots for the grease filters and, for the charcoal filters in recirculation mode, remain easily accessible. S'Please see Page 5 of Specification Sheet for further details. RECEIVED 03/11/2019 AkEdi ai 5 BUILDING DEPARTMENT Miele 36" Built-In Wall Cabinet Hood INSTALLATION SPECIFICATIONS 12 a /ih � 2� 9 �500 o m) 91n5/1�' 2"116y m ( 81 i'e" 518,�9/0 1 I o ag 1 �/ 64 .�` mm �16 151�fi �ih sl+d'g62 gym) (3g0• 3/4u( 9400 (as aq8, -i•- / :: ...,_:, (:),, ,_,: :i., _ s, .._ (3g1/ 11 2'' 'tirri) i Z�1�� 1 Extraction, recirculation with - The side units must also be conversion kit DUU 150. shortened by 1 1/2" (38 mm). s1 Recirculation mode with conversion - The doors of the built-in unit and kit DUU 151. side units must be opened to the top so that the grease filters are 3'The wall unit carcase needs to be 1 accessible. 1/2" (38 mm) shorter than the wall 1 5;Alternatively, the wall unit can be unit door. fitted with side sections. (Ti)Installation is also possible in a 23 RECEIVED 5/8" (600 mm)wide unit. In the RE... FIVE process, the following must be observed: 0 3/11/2 019 / 15 BUILDING DEPARTMENT Miele 36" Built-In Wall Cabinet Hood INSTALLATION SPECIFICATIONS Distance Between Cooktop and Ventilation Hood (S) Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood. Please also observe the information contained in the "IMPORTANT SAFETY INSTRUCTIONS" section of the manual. Minimum distance S Cooking appliance Miele Non-Miele products products Electric Cooktops 24" (610 mm) Electric Barbeques and Fryers 26" (660 mm) Multiburner Gas Cooktops 26" (660 mm) 30" (760 mm) <_ 43,000 BTU/hr (12.6 W), no burner > 15,000 BTU/hr(4.5 kW). Multiburner Gas Cooktops 30" (760 mm) <_ 73,800 BTU/hr (21.6 W), no burner > 16,500 BTU/hr(4.8 kW) Multiburner Gas Cooktops Not possible > 73,800 BTU/hr (21.6 W), or one of the burners> 16,500 BTU/hr(4.8 kW) Single Burner Gas Cooktops 26" (660 mm) 30" (760 mm) <_ 20,500 BTU/hr (6 kW) Single Burner Gas Cooktops 30" (760 mm) > 20,500 BTU/hr (6 kW) 5 27,600 BTU/hr (8.1 kW) Single Burner Gas Cooktops Not possible > 27,600 BTU/hr (8.1 kW) If you are installing a front panel made of wood or plastic to the hood, observe the safety distances given by the cooktop manufacturer regarding the use of easily flammable materials. RECEIVED 03/11/2019 Page 5of5 Specification SheetsTRS05032Q18. •