SPECIFICATIONS 1111101
Overall Unit Dimensions 351/8"(892 mm)W x 141/16"(357 mm)H x 123/16"(309 mm)D[Depth Retracted]
Unit Depth Extended 181/16"(459 mm)
Built-In
Minimum Opening Dimensions 221/8"(562 mm)W x 133/4"(350 mm) H x 123/16"(310 mm)D
Fan
Fan Speeds 4
Maximum CFM 625 CFM,(Reducing Collar is available to reduce Air flow to less than 400 CFM
Duct
Duct Diameter 6"(150 mm)
Electrical
Electrical Requirements 120V,60Hz,15A
Power Cord Molded NEMA 5-15 plug,2.5 ft(0.75 m)
Shipping
Shipping Weight 41.8 lbs(19 kg)
Shipping Dimensions 377/16"W x 201/2" H x 14" D
Support
Call Miele 800.843.7231
Miele Website iiwww.mieleusa.com
20/20 Link JC52020technologies.com
It
DA 3698
Item 28369855USA
RECEIVED
03/11/2019
htEtja E 5
BUILDING DEPARTMENT
Miele
36" Built-In Wall Cabinet Hood
INSTALLATION SPECIFICATIONS
(24 /2„
13/�6') 2r
7 a. 06" O �y03 mm a S,, ^ ^')
c<1 (84 e ri-141)
11141
ga 0
9/16
(3, /
3/8 �A)
(35 gym) y 492
rn ��
23
(300e.,
mn,)
4,ax
(1 5p5 N.,
The ducting can also be connected
at the back.
2 After installation,the wall unit can be
fitted with an interim panel. If this is
done, make sure that the slots for
the grease filters and, for the
charcoal filters in recirculation mode,
remain easily accessible.
S'Please see Page 5 of Specification Sheet
for further details.
RECEIVED
03/11/2019
AkEdi ai 5
BUILDING DEPARTMENT
Miele
36" Built-In Wall Cabinet Hood
INSTALLATION SPECIFICATIONS
12 a /ih
� 2� 9 �500 o
m)
91n5/1�' 2"116y m ( 81 i'e" 518,�9/0
1 I o
ag 1 �/ 64 .�` mm �16
151�fi �ih
sl+d'g62 gym) (3g0• 3/4u(
9400
(as aq8,
-i•- / :: ...,_:,
(:),, ,_,: :i., _ s, .._
(3g1/ 11
2''
'tirri) i
Z�1��
1 Extraction, recirculation with - The side units must also be
conversion kit DUU 150. shortened by 1 1/2" (38 mm).
s1 Recirculation mode with conversion - The doors of the built-in unit and
kit DUU 151. side units must be opened to the
top so that the grease filters are
3'The wall unit carcase needs to be 1 accessible.
1/2" (38 mm) shorter than the wall 1 5;Alternatively, the wall unit can be
unit door. fitted with side sections.
(Ti)Installation is also possible in a 23 RECEIVED
5/8" (600 mm)wide unit. In the RE... FIVE
process, the following must be
observed: 0 3/11/2 019
/ 15
BUILDING DEPARTMENT
Miele
36" Built-In Wall Cabinet Hood
INSTALLATION SPECIFICATIONS
Distance Between Cooktop and
Ventilation Hood (S)
Provided a larger distance is not given by the manufacturer of the cooktop,
follow the minimum safety distances between a cooktop and the bottom of the
hood.
Please also observe the information contained in the "IMPORTANT SAFETY
INSTRUCTIONS" section of the manual.
Minimum distance S
Cooking appliance Miele Non-Miele
products products
Electric Cooktops 24" (610 mm)
Electric Barbeques and Fryers 26" (660 mm)
Multiburner Gas Cooktops 26" (660 mm) 30" (760 mm)
<_ 43,000 BTU/hr (12.6 W),
no burner > 15,000 BTU/hr(4.5 kW).
Multiburner Gas Cooktops 30" (760 mm)
<_ 73,800 BTU/hr (21.6 W),
no burner > 16,500 BTU/hr(4.8 kW)
Multiburner Gas Cooktops Not possible
> 73,800 BTU/hr (21.6 W),
or one of the burners> 16,500 BTU/hr(4.8 kW)
Single Burner Gas Cooktops 26" (660 mm) 30" (760 mm)
<_ 20,500 BTU/hr (6 kW)
Single Burner Gas Cooktops 30" (760 mm)
> 20,500 BTU/hr (6 kW)
5 27,600 BTU/hr (8.1 kW)
Single Burner Gas Cooktops Not possible
> 27,600 BTU/hr (8.1 kW)
If you are installing a front panel made of wood or plastic to the hood, observe
the safety distances given by the cooktop manufacturer regarding the use of
easily flammable materials.