HomeMy WebLinkAboutFile Documents.124 W Hallam St.0025.2017 (43).ARBK 00025-2017-ARBK_BuildingComments_3
PERMIT REVISIONS 02-ARCHITECTURAL.2017.08.31.pdf(4)
- x P a g e: 1
-- •P / Provide stamped design
.� ������ File Name: PERMIT REVISIONS p g
��'it/ 02 ARCHITECTURAL.2017.08.31.pdf drawings of the permanent
i ���� micropiles. Minimum factor of
Subject: PlanCheck
Author: nickt safety is 2.Your response says
Color: • it is forthcoming. I cannot sign off
::::= until it is submitted.
MICROPILE DESIGN WAS SUBMITTED 8/31/17 WITH REVISIONS 02. SEE ATTACHED
Page: 7
File Name: PERMIT REVISIONS The window fall
"•" w' .. , 01 02-ARCHITECTURAL.2017.08.31.pdf protection/opening limiting
NaaaQ�...., ° Subject: PlanCheck devices must be listed to ASTM
Author: nickt F2090. Provide a spec
.• Color • demonstrating that they have
that listing.
Ear°°" SAFEGUARD CASEMENT WINDOW CONTROL DEVICE (WOCD)ATTACHED. F2090 LISTED
-- Page: 31
.___'--. File Name: PERMIT REVISIONS Provide a new REScheck
e i 02-ARCHITECTURAL.2017.08.31.pdf showing the new insulation at
I ___ m j1],--e Subject: PlanCheck the window well
iMar
Author: nickt
a C.uu .___ olor: ■
II!
'di PI m�, UPDATED REScheck ATTACHED. EGRESS WELL INSULATION VALUES UPDATED
Page:46
File Name: PERMIT REVISIONS Skylight on flat roof requires 4"
02-ARC URAL.2017.08.31.pdf curb above roof surface unless
T Subject:: PlanCheck permitted by manufacturer's
Author: nickt instructions(2009 IRC R308.6.8)
fr_ = Color: ■
SEE ATTACHED LETTER FROM SKYLIGHT(INDUSTRIAL SKYLIGHT)MANUFACTURER; SKYLIGHT
SPEC. SECTION ALSO ATTACHED.