HomeMy WebLinkAboutFile Documents.210 S West End St.0020-2020-BCHO 0020-2020-BCHO_BuildingCommentl
210 S West End Architectural CO 1.pdf(6)
Subject: PlanCheck
Page:A-106 FIRE PLAN ELEVATIONS These openings are no longer
Author:justinh required to be protected now
Color: • that the entire building is being
File Name: 210 S West End Architectural CO 1.pdf sprinklered.
o 0
— .4_
0
Subject: PlanCheck
Page:A-401 STAIR DETAILS This is a type I handrail and the
TYPE HAN
BDRAIIL PER Author:justinh IBC reference would be
IRC ... Color: • 1014.3.1, revise note.
File Name: 210 S West End Architectural CO 1.pdf
STEEL FRAME
This Is a type I handrail
and the IBC reference
would be 1014.3.1,
WOODTREAD- revise note.
WRAP STEEL
STRUCTURE AS
NECESSARY
I Subject: PlanCheck Revise note to state type I
Page:A-401 STAIR DETAILS
Revise note to state handrail,type II handrails
type l handrail,type II Author:justinh
I handrails exceed a exceed a perimeter of 6.25"and
Perimeter of 6.25"and Color: •
have finger recesses have finger recesses.
I
/ File Name: 210 S West End Architectural CO 1.pdf
TYPE2RANDRAI )
(fir 36'ABOVE NOSING
II GUARDRAIL /\
_ L
,;;-i�■"I Subject: PlanCheck
i 'i'I In` °!" Page:A-402 BACK STAIR DETAILS The handrail extension is
ft1 required toi extend to the bottom
__ I - Author:justinh
? ' v riser,this is shown as stopping
Ill Wit �' � o- QUO Color: • just short of that. Revise to
A .w
1Lr. File Name: 210 S West End Architectural CO 1.pdf comply.
u
Subject: PlanCheck
Page:A-403 FIREPLACE DETAILS Provide an updated fireplace
Author:justinh registration form.
Color: •
„Po.a File Name: 210 S West End Architectural CO 1.pdf
a===a Subject: PlanCheck
Page:A-403 FIREPLACE DETAILS Is this existing fireplace a site
.Ps Author:justinh built masonry fireplace or is it a
Color: • factory build unit? A masonry
File Name: 210 S West End Architectural CO 1.pdf fireplace is required to be
completely supported by
non-combustible materials,
Wig
including the hearth extension,
which I don't see shown in the
structural plan. Please clarify
what this fireplace is and show
how this alteration either
complies with IBC 2111.10 if it is
a masonry fireplace or the unit's
installation instructions if it is a
factory built unit.
210 S West End REMP Rev..pdf(3)
Subject: PlanCheck
Page: 1 Fill this portion of the form out in
Author:justinh excel rather than by hand and it
Color: • will populate the refund cell, you
File Name: 210 S West End REMP Rev..pdf
will want this filled out properly in
1 order to request a refund for fees
paid that are now being
mitigated against.
Subject: PlanCheck
Page: 2 You did not fill out any inverter
:... .r, capacity information. Provide
22; 2 0. 2 Author:justinh
Color: •■ specs on the panels and
IMREe" ear=aoBery " P�as File Name: 210 S West End REMP Rev..pdf inverters you are proposing and
specs
on
enpael and Inverters you are proposing
n ,taa° '¢a and
include inverter capacity on this
factor on the energy the system produces.
form as that will be a limiting
1111111111111 .... factor on the energy the system
e mi—!_- ,7.. produces.
Subject: PlanCheck
Page: 2 I get different measurements for
Author:justinh the degrees from true south per
Color: • the roof plan than what you
File Name: 210 S West End REMP Rev..pdf show here, please clarify how
you are measuring your angle.
Provide a reference for true
north on the roof plan if the north
arrow shown is not
representative of that(I measure
the panels on the 4/12 pitch roof
as being 50 degrees from true
south, and the panels on 9/12
pitch as 40 degrees from true
south relative to your north
arrow).