HomeMy WebLinkAboutFile Documents.183 Red Mountain Rd.0038.2018 (7).ARBK 0038-2018-ARBK_BuildingComment3
Architecture Set.183 Red Mtn Rd.2018.01.pdf(1)
Subject: PlanCheck✓
11 i Page Label:A1.08 LOWER LEVELFLOOR PLAN Previous comment not
Author:justinh addressed correctly. You are
- C - File Name: Architecture Set.183 Red Mtn Rd.2018.01.pdf
now showing T.O.F.F. below
p
—ee P Color: • your T.O. Ply elevation, both of
m..; which are still lower than the
1f i T.O.F.F. elevation you show on
F :: �" Typo. Revised to 88'-8 1/4" the exterior landing,which is not
ftl� L1 consistent with your typical
i ° �� � exterior door detail. Please
o ! - revise.
Pool. 183 Red Mtn Rd. 2018.01.pdf(1)
Subject: PlanCheck ✓
Page Label: [5] Unsaved Drawing1-PL1.3 SPA REMP fees are calculated on the
Author:justinh surface area of the water for
File Name: Pool. 183 Red Mtn Rd. 2018.01.pdf spas and pools. The seating
Color: • area of this spa is 43 SF but the
actual square footage of heater
_ water surface area is roughly
/ REMP worksheet revised to show 133 sf at 133 SF per these plans. Revise
the spa. and resubmit the REMP
worksheet.
Structural Set.183 Red Mtn Rd.2018.01.pdf(2)
L, Subject: PlanCheck
Page Label: 3 ./ Previous comment regarding the
Author:justinh dewatering system not
4 completely resolved, no
, , File Name: Structural Set.183 Red Mtn Rd.2018.01.pdf informationprovided
C olor. • was
t.
MT'
-o regarding the permanent system
J u
It was determined that the floor drains in the only the temp system to be used
during construction. Identify the
T w N basement will drain to the sump pump and:mipAtim discharge termination location of
iia1L discharge out the sanitary sewer. This note is these two sump pits in
on P-1 10 relationship to the 100 year flood
line, 15'top of slope setback
line, and your storm water
infrastructure to compliant
termination location (C5.0 in the
civil set would be an ideal place
to show this). Provide a detail
for the discharge termination to
show how erosion will be
avoided.
Subject: PlanCheck
Page Label: 13 Sheet S6.01 is not stamped,
Author:justinh resubmit a stamped and signed
File Name: Structural Set.183 Red Mtn Rd.2018.01.pdf copy of this sheet.
msE Color: •
Stamped sheet attached.