Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.216 S Monarch St.0055.2019 (7).ACBK
0055-2019-ACBK_216 S Monarch_BuildingComment2 190808_Permit Set_Arch_Stamped.pdf(5) =„ Subject: PlanCheck Page Label:A0.00 After further discussion with Author:justinh inspection staff and the building File Name: 190808_Permit Set_Arch_Stamped.pdf official it has been determined Color: • that a mechanical plan will be required demonstrating the °_°'=" scope of work outlined in the letters submitted by AEC and AVMM. As this requirement is being brought up late during the review process we are willing to take it as a deferred submittal and issue the building permit without it, but it will be required to be submitted for review/approval prior to any mechanical inspections taking place. Inspection staff wants to be able to reference an actual plan that shows what is required and where so that there are no issues with the contractor during construction and inspection. Mechanical inspections will not be provided until this plan has been reviewed and issued and is part of the field set of construction documents. ■; ■ Subject: PlanCheck ®j; ■;;-.rI IBC 1010.1.2 does not allow a Page Label:A2.00 ___ "� pocket type door in this location Author:justinh 1,--, - File Name: 190808_Permit Set_Arch_Stamped.pdf with an occupant load greater `''� Color: • than 10 within the room, it would 7,o,o).,�b r need to be a pivoted/side hinged swinging type door or be . - removed entirely. Please revise, brc I apologize for not catching this during my initial review. —,. � "L.,— I Subject: PlanCheck Page Label: A2.00 Please show the accessible seat II Author:justinh along the long side of the table '1 ■{MI - I� _ File Name: 190808_Permit Set_Arch_Stamped.pdf at a different location so that it is in �� 1: Color: ■ not overlapping into the -'1 � accessible route. l ,i- o , JI___ Subject: PlanCheck Page Label:A2.01 I do not see why the rotisserie 0 0 © o would not be required to be Author:justinh under your hood per the spec File Name: 190808_Permit Set_Arch_Stamped.pdf submitted for the rotisserie. Color: •1 pril Please clarify why this would not be required or revise as needed. 1 si n o a' a y Subject: PlanCheck Page Label:A2.01 Please revise to show the 4A2. Author:justinh accessible route and required I' C'°. clearances at the accessible 'I�'i,r-� ® , , File Name: 190808 Permit Set Arch Stamped.pdf rr m 190808_Permit — seats not overlapping. The clear . r sit [i mN?.;:.;w',,"Ft:b" Color: • am .�I, ,�,_ f space at the tables should be '� i „„ shown tucked up to 17" into the tom Nil ,,, table demonstrating the required knee and toe clearance, and you _® , `=_p�:" have some space to work with between tables down the middle aisle as only 38"is required between adjacent tables per IBC 1029.12.1. Between those two items you should be able to get the clear space out of the route.